CVE-2025-36857 (GCVE-0-2025-36857)

Vulnerability from cvelistv5 – Published: 2025-09-25 14:41 – Updated: 2025-09-25 16:03
VLAI
Title
Rapid7 Appspider Broken Access Control Vulnerability
Summary
Rapid7 Appspider Pro versions below 7.5.021, suffer from a broken access control vulnerability in the application's configuration file loading mechanism, whereby an attacker can place files in directories belonging to other users or projects. Affected versions allow standard users to add custom configuration files. These files, which are loaded in alphabetical order, can override or change the settings of the original configuration files, creating a security vulnerability. This issue stems from improper directory access management. This vulnerability was remediated in version 7.5.021 of the product.
SSVC
Exploitation: none Automatable: no Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2025-09-25 15:43 UTC
CWE
  • CWE-276 - Incorrect Default Permissions
Assigner
rapid7 CNA under the mitre root
CNA scorecard B 76/100 over 57 records in the last 180 days details
Impacted products
Vendor Product Version CPE status
Rapid7 Appspider Pro Affected: 0 , < 7.5.021 (custom)
guessed Create a notification for this product.
Date Public
2025-09-17 08:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-36857",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-09-25T15:43:00.532456Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-09-25T16:03:45.231Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Appspider Pro",
          "vendor": "Rapid7",
          "versions": [
            {
              "lessThan": "7.5.021",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Thank you to Maksymilian Kubiak [Afine Team] for the responsible disclosure to Rapid7"
        }
      ],
      "datePublic": "2025-09-17T08:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Rapid7 Appspider Pro versions below 7.5.021, suffer from a broken access control vulnerability in the application\u0027s configuration file loading mechanism, whereby an attacker can\u0026nbsp;place files in directories belonging to other users or projects. Affected versions allow standard users to add custom configuration files. These files, which are loaded in alphabetical order, can override or change the settings of the original configuration files, creating a security vulnerability. This issue stems from improper directory access management.\u003cbr\u003e\u003cbr\u003eThis vulnerability was remediated in version 7.5.021 of the product."
            }
          ],
          "value": "Rapid7 Appspider Pro versions below 7.5.021, suffer from a broken access control vulnerability in the application\u0027s configuration file loading mechanism, whereby an attacker can\u00a0place files in directories belonging to other users or projects. Affected versions allow standard users to add custom configuration files. These files, which are loaded in alphabetical order, can override or change the settings of the original configuration files, creating a security vulnerability. This issue stems from improper directory access management.\n\nThis vulnerability was remediated in version 7.5.021 of the product."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "NONE",
            "baseScore": 3.3,
            "baseSeverity": "LOW",
            "confidentialityImpact": "NONE",
            "integrityImpact": "LOW",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-276",
              "description": "CWE-276 Incorrect Default Permissions",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-09-25T14:41:35.939Z",
        "orgId": "9974b330-7714-4307-a722-5648477acda7",
        "shortName": "rapid7"
      },
      "references": [
        {
          "url": "https://docs.rapid7.com/insight/releasenotes-2025sep/#application-security-insightappsec-and-appspider"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Rapid7 Appspider Broken Access Control Vulnerability",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "9974b330-7714-4307-a722-5648477acda7",
    "assignerShortName": "rapid7",
    "cveId": "CVE-2025-36857",
    "datePublished": "2025-09-25T14:41:35.939Z",
    "dateReserved": "2025-04-16T00:09:11.312Z",
    "dateUpdated": "2025-09-25T16:03:45.231Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "epss": {
      "cve": "CVE-2025-36857",
      "date": "2026-10-11",
      "epss": "0.00127",
      "percentile": "0.02072"
    },
    "nvd": {
      "cve": {
        "affected": [
          {
            "affectedData": [
              {
                "defaultStatus": "unaffected",
                "product": "Appspider Pro",
                "vendor": "Rapid7",
                "versions": [
                  {
                    "lessThan": "7.5.021",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "source": "cve@rapid7.com"
          }
        ],
        "configurations": [
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:a:rapid7:appspider_pro:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "6B4810BF-FEF3-4E95-B968-B85651369A88",
                    "versionEndExcluding": "7.5.021",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ]
          }
        ],
        "cveTags": [],
        "descriptions": [
          {
            "lang": "en",
            "value": "Rapid7 Appspider Pro versions below 7.5.021, suffer from a broken access control vulnerability in the application\u0027s configuration file loading mechanism, whereby an attacker can\u00a0place files in directories belonging to other users or projects. Affected versions allow standard users to add custom configuration files. These files, which are loaded in alphabetical order, can override or change the settings of the original configuration files, creating a security vulnerability. This issue stems from improper directory access management.\n\nThis vulnerability was remediated in version 7.5.021 of the product."
          },
          {
            "lang": "es",
            "value": "Las versiones de Rapid7 Appspider Pro anteriores a la 7.5.021, sufren de una vulnerabilidad de control de acceso roto en el mecanismo de carga de archivos de configuraci\u00f3n de la aplicaci\u00f3n, mediante la cual un atacante puede colocar archivos en directorios pertenecientes a otros usuarios o proyectos. Las versiones afectadas permiten a los usuarios est\u00e1ndar a\u00f1adir archivos de configuraci\u00f3n personalizados. Estos archivos, que se cargan en orden alfab\u00e9tico, pueden anular o cambiar la configuraci\u00f3n de los archivos de configuraci\u00f3n originales, creando una vulnerabilidad de seguridad. Este problema se deriva de una gesti\u00f3n inadecuada del acceso a directorios.\n\nEsta vulnerabilidad fue corregida en la versi\u00f3n 7.5.021 del producto."
          }
        ],
        "id": "CVE-2025-36857",
        "lastModified": "2026-10-11T20:10:00.200",
        "metrics": {
          "cvssMetricV31": [
            {
              "cvssData": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "NONE",
                "baseScore": 3.3,
                "baseSeverity": "LOW",
                "confidentialityImpact": "NONE",
                "integrityImpact": "LOW",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:N",
                "version": "3.1"
              },
              "exploitabilityScore": 1.8,
              "impactScore": 1.4,
              "source": "cve@rapid7.com",
              "type": "Secondary"
            }
          ],
          "ssvcV203": [
            {
              "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "ssvcData": {
                "id": "CVE-2025-36857",
                "options": [
                  {
                    "exploitation": "none"
                  },
                  {
                    "automatable": "no"
                  },
                  {
                    "technicalImpact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-09-25T15:43:00.532456Z",
                "version": "2.0.3"
              }
            }
          ]
        },
        "published": "2025-09-25T15:16:11.060",
        "references": [
          {
            "source": "cve@rapid7.com",
            "tags": [
              "Vendor Advisory"
            ],
            "url": "https://docs.rapid7.com/insight/releasenotes-2025sep/#application-security-insightappsec-and-appspider"
          }
        ],
        "sourceIdentifier": "cve@rapid7.com",
        "vulnStatus": "Analyzed",
        "weaknesses": [
          {
            "description": [
              {
                "lang": "en",
                "value": "CWE-276"
              }
            ],
            "source": "cve@rapid7.com",
            "type": "Secondary"
          }
        ]
      }
    },
    "redhat_vex": {
      "current_release_date": "2025-09-26T14:48:15+00:00",
      "cve": "CVE-2025-36857",
      "id": "CVE-2025-36857",
      "initial_release_date": "2025-09-17T08:00:00+00:00",
      "product_status:known_not_affected": "1",
      "source": "Red Hat CSAF VEX",
      "status": "final",
      "title": "Rapid7 Appspider Broken Access Control Vulnerability",
      "url": "https://security.access.redhat.com/data/csaf/v2/vex/2025/cve-2025-36857.json",
      "version": "3"
    },
    "vulnrichment": {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-36857",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-09-25T15:43:00.532456Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-09-25T16:03:30.714Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Appspider Pro",
              "vendor": "Rapid7",
              "versions": [
                {
                  "lessThan": "7.5.021",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Thank you to Maksymilian Kubiak [Afine Team] for the responsible disclosure to Rapid7"
            }
          ],
          "datePublic": "2025-09-17T08:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Rapid7 Appspider Pro versions below 7.5.021, suffer from a broken access control vulnerability in the application\u0027s configuration file loading mechanism, whereby an attacker can\u0026nbsp;place files in directories belonging to other users or projects. Affected versions allow standard users to add custom configuration files. These files, which are loaded in alphabetical order, can override or change the settings of the original configuration files, creating a security vulnerability. This issue stems from improper directory access management.\u003cbr\u003e\u003cbr\u003eThis vulnerability was remediated in version 7.5.021 of the product."
                }
              ],
              "value": "Rapid7 Appspider Pro versions below 7.5.021, suffer from a broken access control vulnerability in the application\u0027s configuration file loading mechanism, whereby an attacker can\u00a0place files in directories belonging to other users or projects. Affected versions allow standard users to add custom configuration files. These files, which are loaded in alphabetical order, can override or change the settings of the original configuration files, creating a security vulnerability. This issue stems from improper directory access management.\n\nThis vulnerability was remediated in version 7.5.021 of the product."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "NONE",
                "baseScore": 3.3,
                "baseSeverity": "LOW",
                "confidentialityImpact": "NONE",
                "integrityImpact": "LOW",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-276",
                  "description": "CWE-276 Incorrect Default Permissions",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-09-25T14:41:35.939Z",
            "orgId": "9974b330-7714-4307-a722-5648477acda7",
            "shortName": "rapid7"
          },
          "references": [
            {
              "url": "https://docs.rapid7.com/insight/releasenotes-2025sep/#application-security-insightappsec-and-appspider"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Rapid7 Appspider Broken Access Control Vulnerability",
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "9974b330-7714-4307-a722-5648477acda7",
        "assignerShortName": "rapid7",
        "cveId": "CVE-2025-36857",
        "datePublished": "2025-09-25T14:41:35.939Z",
        "dateReserved": "2025-04-16T00:09:11.312Z",
        "dateUpdated": "2025-09-25T16:03:45.231Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Loading…

Loading…

Related by attack behaviour

Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.


Loading…