CVE-2025-61848 (GCVE-0-2025-61848)

Vulnerability from cvelistv5 – Published: 2026-04-14 15:38 – Updated: 2026-04-14 16:46
VLAI?
Summary
An improper neutralization of special elements used in an sql command ('sql injection') vulnerability in Fortinet FortiAnalyzer 7.6.0 through 7.6.4, FortiAnalyzer 7.4.0 through 7.4.8, FortiAnalyzer 7.2 all versions, FortiAnalyzer 7.0 all versions, FortiAnalyzer Cloud 7.6.0 through 7.6.4, FortiAnalyzer Cloud 7.4.0 through 7.4.8, FortiAnalyzer Cloud 7.2 all versions, FortiAnalyzer Cloud 7.0 all versions, FortiManager 7.6.0 through 7.6.4, FortiManager 7.4.0 through 7.4.8, FortiManager 7.2 all versions, FortiManager 7.0 all versions, FortiManager Cloud 7.6.0 through 7.6.4, FortiManager Cloud 7.4.0 through 7.4.8, FortiManager Cloud 7.2 all versions, FortiManager Cloud 7.0 all versions may allow a privileged authenticated attacker to execute unauthorized code or commands via JSON RPC API
CWE
  • CWE-89 - Execute unauthorized code or commands
Assigner
Impacted products
Vendor Product Version
Fortinet FortiManager Affected: 7.6.0 , ≤ 7.6.3 (semver)
    cpe:2.3:o:fortinet:fortimanager:7.6.3:*:*:*:*:*:*:*
    cpe:2.3:o:fortinet:fortimanager:7.6.2:*:*:*:*:*:*:*
    cpe:2.3:o:fortinet:fortimanager:7.6.1:*:*:*:*:*:*:*
    cpe:2.3:o:fortinet:fortimanager:7.6.0:*:*:*:*:*:*:*
Create a notification for this product.
    Fortinet FortiAnalyzer Affected: 7.6.0 , ≤ 7.6.3 (semver)
    cpe:2.3:o:fortinet:fortianalyzer:7.6.3:*:*:*:*:*:*:*
    cpe:2.3:o:fortinet:fortianalyzer:7.6.2:*:*:*:*:*:*:*
    cpe:2.3:o:fortinet:fortianalyzer:7.6.1:*:*:*:*:*:*:*
    cpe:2.3:o:fortinet:fortianalyzer:7.6.0:*:*:*:*:*:*:*
Create a notification for this product.
    Fortinet FortiManager Cloud Affected: 7.6.2 , ≤ 7.6.4 (semver)
    cpe:2.3:a:fortinet:fortimanagercloud:7.6.4:*:*:*:*:*:*:*
    cpe:2.3:a:fortinet:fortimanagercloud:7.6.3:*:*:*:*:*:*:*
    cpe:2.3:a:fortinet:fortimanagercloud:7.6.2:*:*:*:*:*:*:*
Create a notification for this product.
    Fortinet FortiAnalyzer Cloud Affected: 7.6.2 , ≤ 7.6.3 (semver)
    cpe:2.3:a:fortinet:fortianalyzercloud:7.6.3:*:*:*:*:*:*:*
    cpe:2.3:a:fortinet:fortianalyzercloud:7.6.2:*:*:*:*:*:*:*
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-61848",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-04-14T16:18:13.242317Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-04-14T16:46:14.508Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "cpes": [
            "cpe:2.3:o:fortinet:fortimanager:7.6.3:*:*:*:*:*:*:*",
            "cpe:2.3:o:fortinet:fortimanager:7.6.2:*:*:*:*:*:*:*",
            "cpe:2.3:o:fortinet:fortimanager:7.6.1:*:*:*:*:*:*:*",
            "cpe:2.3:o:fortinet:fortimanager:7.6.0:*:*:*:*:*:*:*"
          ],
          "defaultStatus": "unaffected",
          "product": "FortiManager",
          "vendor": "Fortinet",
          "versions": [
            {
              "lessThanOrEqual": "7.6.3",
              "status": "affected",
              "version": "7.6.0",
              "versionType": "semver"
            }
          ]
        },
        {
          "cpes": [
            "cpe:2.3:o:fortinet:fortianalyzer:7.6.3:*:*:*:*:*:*:*",
            "cpe:2.3:o:fortinet:fortianalyzer:7.6.2:*:*:*:*:*:*:*",
            "cpe:2.3:o:fortinet:fortianalyzer:7.6.1:*:*:*:*:*:*:*",
            "cpe:2.3:o:fortinet:fortianalyzer:7.6.0:*:*:*:*:*:*:*"
          ],
          "defaultStatus": "unaffected",
          "product": "FortiAnalyzer",
          "vendor": "Fortinet",
          "versions": [
            {
              "lessThanOrEqual": "7.6.3",
              "status": "affected",
              "version": "7.6.0",
              "versionType": "semver"
            }
          ]
        },
        {
          "cpes": [
            "cpe:2.3:a:fortinet:fortimanagercloud:7.6.4:*:*:*:*:*:*:*",
            "cpe:2.3:a:fortinet:fortimanagercloud:7.6.3:*:*:*:*:*:*:*",
            "cpe:2.3:a:fortinet:fortimanagercloud:7.6.2:*:*:*:*:*:*:*"
          ],
          "defaultStatus": "unaffected",
          "product": "FortiManager Cloud",
          "vendor": "Fortinet",
          "versions": [
            {
              "lessThanOrEqual": "7.6.4",
              "status": "affected",
              "version": "7.6.2",
              "versionType": "semver"
            }
          ]
        },
        {
          "cpes": [
            "cpe:2.3:a:fortinet:fortianalyzercloud:7.6.3:*:*:*:*:*:*:*",
            "cpe:2.3:a:fortinet:fortianalyzercloud:7.6.2:*:*:*:*:*:*:*"
          ],
          "defaultStatus": "unaffected",
          "product": "FortiAnalyzer Cloud",
          "vendor": "Fortinet",
          "versions": [
            {
              "lessThanOrEqual": "7.6.3",
              "status": "affected",
              "version": "7.6.2",
              "versionType": "semver"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "An improper neutralization of special elements used in an sql command (\u0027sql injection\u0027) vulnerability in Fortinet FortiAnalyzer 7.6.0 through 7.6.4, FortiAnalyzer 7.4.0 through 7.4.8, FortiAnalyzer 7.2 all versions, FortiAnalyzer 7.0 all versions, FortiAnalyzer Cloud 7.6.0 through 7.6.4, FortiAnalyzer Cloud 7.4.0 through 7.4.8, FortiAnalyzer Cloud 7.2 all versions, FortiAnalyzer Cloud 7.0 all versions, FortiManager 7.6.0 through 7.6.4, FortiManager 7.4.0 through 7.4.8, FortiManager 7.2 all versions, FortiManager 7.0 all versions, FortiManager Cloud 7.6.0 through 7.6.4, FortiManager Cloud 7.4.0 through 7.4.8, FortiManager Cloud 7.2 all versions, FortiManager Cloud 7.0 all versions may allow a privileged authenticated attacker to execute unauthorized code or commands via JSON RPC API"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 6.8,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          },
          "format": "CVSS"
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-89",
              "description": "Execute unauthorized code or commands",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-04-14T15:38:24.009Z",
        "orgId": "6abe59d8-c742-4dff-8ce8-9b0ca1073da8",
        "shortName": "fortinet"
      },
      "references": [
        {
          "name": "https://fortiguard.fortinet.com/psirt/FG-IR-26-111",
          "url": "https://fortiguard.fortinet.com/psirt/FG-IR-26-111"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "value": "Upgrade to upcoming  FortiManager version 8.0.0 or above\nUpgrade to FortiManager version 7.6.5 or above\nUpgrade to FortiManager version 7.4.9 or above\nUpgrade to FortiAnalyzer version 7.6.5 or above\nUpgrade to FortiAnalyzer version 7.4.9 or above\nUpgrade to FortiAnalyzer Cloud version 7.6.4 or above\nUpgrade to FortiManager Cloud version 7.6.5 or above"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "6abe59d8-c742-4dff-8ce8-9b0ca1073da8",
    "assignerShortName": "fortinet",
    "cveId": "CVE-2025-61848",
    "datePublished": "2026-04-14T15:38:24.009Z",
    "dateReserved": "2025-10-01T18:21:09.224Z",
    "dateUpdated": "2026-04-14T16:46:14.508Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2",
  "vulnerability-lookup:meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2025-61848\",\"sourceIdentifier\":\"psirt@fortinet.com\",\"published\":\"2026-04-14T16:16:31.610\",\"lastModified\":\"2026-04-14T16:16:31.610\",\"vulnStatus\":\"Received\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"An improper neutralization of special elements used in an sql command (\u0027sql injection\u0027) vulnerability in Fortinet FortiAnalyzer 7.6.0 through 7.6.4, FortiAnalyzer 7.4.0 through 7.4.8, FortiAnalyzer 7.2 all versions, FortiAnalyzer 7.0 all versions, FortiAnalyzer Cloud 7.6.0 through 7.6.4, FortiAnalyzer Cloud 7.4.0 through 7.4.8, FortiAnalyzer Cloud 7.2 all versions, FortiAnalyzer Cloud 7.0 all versions, FortiManager 7.6.0 through 7.6.4, FortiManager 7.4.0 through 7.4.8, FortiManager 7.2 all versions, FortiManager 7.0 all versions, FortiManager Cloud 7.6.0 through 7.6.4, FortiManager Cloud 7.4.0 through 7.4.8, FortiManager Cloud 7.2 all versions, FortiManager Cloud 7.0 all versions may allow a privileged authenticated attacker to execute unauthorized code or commands via JSON RPC API\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"psirt@fortinet.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":7.2,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"HIGH\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":1.2,\"impactScore\":5.9}]},\"weaknesses\":[{\"source\":\"psirt@fortinet.com\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-89\"}]}],\"references\":[{\"url\":\"https://fortiguard.fortinet.com/psirt/FG-IR-26-111\",\"source\":\"psirt@fortinet.com\"}]}}",
    "vulnrichment": {
      "containers": "{\"adp\": [{\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2025-61848\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"total\"}], \"version\": \"2.0.3\", \"timestamp\": \"2026-04-14T16:18:13.242317Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2026-04-14T16:36:57.861Z\"}}], \"cna\": {\"metrics\": [{\"format\": \"CVSS\", \"cvssV3_1\": {\"scope\": \"UNCHANGED\", \"version\": \"3.1\", \"baseScore\": 6.8, \"attackVector\": \"NETWORK\", \"baseSeverity\": \"MEDIUM\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C\", \"integrityImpact\": \"HIGH\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"HIGH\", \"privilegesRequired\": \"HIGH\", \"confidentialityImpact\": \"HIGH\"}}], \"affected\": [{\"cpes\": [\"cpe:2.3:o:fortinet:fortimanager:7.6.3:*:*:*:*:*:*:*\", \"cpe:2.3:o:fortinet:fortimanager:7.6.2:*:*:*:*:*:*:*\", \"cpe:2.3:o:fortinet:fortimanager:7.6.1:*:*:*:*:*:*:*\", \"cpe:2.3:o:fortinet:fortimanager:7.6.0:*:*:*:*:*:*:*\"], \"vendor\": \"Fortinet\", \"product\": \"FortiManager\", \"versions\": [{\"status\": \"affected\", \"version\": \"7.6.0\", \"versionType\": \"semver\", \"lessThanOrEqual\": \"7.6.3\"}], \"defaultStatus\": \"unaffected\"}, {\"cpes\": [\"cpe:2.3:o:fortinet:fortianalyzer:7.6.3:*:*:*:*:*:*:*\", \"cpe:2.3:o:fortinet:fortianalyzer:7.6.2:*:*:*:*:*:*:*\", \"cpe:2.3:o:fortinet:fortianalyzer:7.6.1:*:*:*:*:*:*:*\", \"cpe:2.3:o:fortinet:fortianalyzer:7.6.0:*:*:*:*:*:*:*\"], \"vendor\": \"Fortinet\", \"product\": \"FortiAnalyzer\", \"versions\": [{\"status\": \"affected\", \"version\": \"7.6.0\", \"versionType\": \"semver\", \"lessThanOrEqual\": \"7.6.3\"}], \"defaultStatus\": \"unaffected\"}, {\"cpes\": [\"cpe:2.3:a:fortinet:fortimanagercloud:7.6.4:*:*:*:*:*:*:*\", \"cpe:2.3:a:fortinet:fortimanagercloud:7.6.3:*:*:*:*:*:*:*\", \"cpe:2.3:a:fortinet:fortimanagercloud:7.6.2:*:*:*:*:*:*:*\"], \"vendor\": \"Fortinet\", \"product\": \"FortiManager Cloud\", \"versions\": [{\"status\": \"affected\", \"version\": \"7.6.2\", \"versionType\": \"semver\", \"lessThanOrEqual\": \"7.6.4\"}], \"defaultStatus\": \"unaffected\"}, {\"cpes\": [\"cpe:2.3:a:fortinet:fortianalyzercloud:7.6.3:*:*:*:*:*:*:*\", \"cpe:2.3:a:fortinet:fortianalyzercloud:7.6.2:*:*:*:*:*:*:*\"], \"vendor\": \"Fortinet\", \"product\": \"FortiAnalyzer Cloud\", \"versions\": [{\"status\": \"affected\", \"version\": \"7.6.2\", \"versionType\": \"semver\", \"lessThanOrEqual\": \"7.6.3\"}], \"defaultStatus\": \"unaffected\"}], \"solutions\": [{\"lang\": \"en\", \"value\": \"Upgrade to upcoming  FortiManager version 8.0.0 or above\\nUpgrade to FortiManager version 7.6.5 or above\\nUpgrade to FortiManager version 7.4.9 or above\\nUpgrade to FortiAnalyzer version 7.6.5 or above\\nUpgrade to FortiAnalyzer version 7.4.9 or above\\nUpgrade to FortiAnalyzer Cloud version 7.6.4 or above\\nUpgrade to FortiManager Cloud version 7.6.5 or above\"}], \"references\": [{\"url\": \"https://fortiguard.fortinet.com/psirt/FG-IR-26-111\", \"name\": \"https://fortiguard.fortinet.com/psirt/FG-IR-26-111\"}], \"descriptions\": [{\"lang\": \"en\", \"value\": \"An improper neutralization of special elements used in an sql command (\u0027sql injection\u0027) vulnerability in Fortinet FortiAnalyzer 7.6.0 through 7.6.4, FortiAnalyzer 7.4.0 through 7.4.8, FortiAnalyzer 7.2 all versions, FortiAnalyzer 7.0 all versions, FortiAnalyzer Cloud 7.6.0 through 7.6.4, FortiAnalyzer Cloud 7.4.0 through 7.4.8, FortiAnalyzer Cloud 7.2 all versions, FortiAnalyzer Cloud 7.0 all versions, FortiManager 7.6.0 through 7.6.4, FortiManager 7.4.0 through 7.4.8, FortiManager 7.2 all versions, FortiManager 7.0 all versions, FortiManager Cloud 7.6.0 through 7.6.4, FortiManager Cloud 7.4.0 through 7.4.8, FortiManager Cloud 7.2 all versions, FortiManager Cloud 7.0 all versions may allow a privileged authenticated attacker to execute unauthorized code or commands via JSON RPC API\"}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-89\", \"description\": \"Execute unauthorized code or commands\"}]}], \"providerMetadata\": {\"orgId\": \"6abe59d8-c742-4dff-8ce8-9b0ca1073da8\", \"shortName\": \"fortinet\", \"dateUpdated\": \"2026-04-14T15:38:24.009Z\"}}}",
      "cveMetadata": "{\"cveId\": \"CVE-2025-61848\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2026-04-14T16:46:14.508Z\", \"dateReserved\": \"2025-10-01T18:21:09.224Z\", \"assignerOrgId\": \"6abe59d8-c742-4dff-8ce8-9b0ca1073da8\", \"datePublished\": \"2026-04-14T15:38:24.009Z\", \"assignerShortName\": \"fortinet\"}",
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.


Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…