FKIE_CVE-2019-12687
Vulnerability from fkie_nvd - Published: 2019-10-02 19:15 - Updated: 2024-11-26 16:09
Severity ?
Summary
A vulnerability in the web UI of the Cisco Firepower Management Center (FMC) could allow an authenticated, remote attacker to execute arbitrary commands on an affected device. The vulnerability is due to insufficient input validation. An attacker could exploit this vulnerability by sending crafted input to the web UI. A successful exploit could allow the attacker to execute arbitrary commands within the affected device.
References
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| cisco | secure_firewall_management_center | 6.2.2 | |
| cisco | secure_firewall_management_center | 6.2.3 |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:cisco:secure_firewall_management_center:6.2.2:*:*:*:*:*:*:*",
"matchCriteriaId": "3B5233F7-5743-467C-9C59-F5C51B47184A",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:cisco:secure_firewall_management_center:6.2.3:*:*:*:*:*:*:*",
"matchCriteriaId": "6175407A-207E-4844-B150-EA0129C4CBBD",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability in the web UI of the Cisco Firepower Management Center (FMC) could allow an authenticated, remote attacker to execute arbitrary commands on an affected device. The vulnerability is due to insufficient input validation. An attacker could exploit this vulnerability by sending crafted input to the web UI. A successful exploit could allow the attacker to execute arbitrary commands within the affected device."
},
{
"lang": "es",
"value": "Una vulnerabilidad en la Interfaz de Usuario web del Cisco Firepower Management Center (FMC), podr\u00eda permitir a un atacante remoto autenticado ejecutar comandos arbitrarios sobre un dispositivo afectado. La vulnerabilidad es debido a una comprobaci\u00f3n de entrada insuficiente. Un atacante podr\u00eda explotar esta vulnerabilidad mediante el env\u00edo de entradas dise\u00f1adas hacia la Interfaz de Usuario web. Una explotaci\u00f3n con \u00e9xito podr\u00eda permitir al atacante ejecutar comandos arbitrarios dentro del dispositivo afectado."
}
],
"id": "CVE-2019-12687",
"lastModified": "2024-11-26T16:09:02.407",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "HIGH",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"availabilityImpact": "COMPLETE",
"baseScore": 9.0,
"confidentialityImpact": "COMPLETE",
"integrityImpact": "COMPLETE",
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
},
"exploitabilityScore": 8.0,
"impactScore": 10.0,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV30": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"exploitabilityScore": 2.8,
"impactScore": 5.9,
"source": "psirt@cisco.com",
"type": "Secondary"
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2019-10-02T19:15:13.017",
"references": [
{
"source": "psirt@cisco.com",
"tags": [
"Vendor Advisory"
],
"url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20191002-fmc-rce"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20191002-fmc-rce"
}
],
"sourceIdentifier": "psirt@cisco.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-119"
}
],
"source": "psirt@cisco.com",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-20"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…