FKIE_CVE-2020-5332

Vulnerability from fkie_nvd - Published: 2020-05-04 19:15 - Updated: 2024-11-21 05:33
Summary
RSA Archer, versions prior to 6.7 P3 (6.7.0.3), contain a command injection vulnerability. AN authenticated malicious user with administrator privileges could potentially exploit this vulnerability to execute arbitrary commands on the system where the vulnerable application is deployed.
Impacted products
Vendor Product Version
rsa archer *

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:rsa:archer:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "7BC36E36-4DFC-4C04-89FE-C99882ED5816",
              "versionEndExcluding": "6.7.0.3",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "RSA Archer, versions prior to 6.7 P3 (6.7.0.3), contain a command injection vulnerability. AN authenticated malicious user with administrator privileges could potentially exploit this vulnerability to execute arbitrary commands on the system where the vulnerable application is deployed."
    },
    {
      "lang": "es",
      "value": "RSA Archer, versiones anteriores a la versi\u00f3n 6.7 P3 (6.7.0.3), contienen una vulnerabilidad de inyecci\u00f3n de comandos. Un usuario malicioso autenticado con privilegios de administrador podr\u00eda explotar potencialmente esta vulnerabilidad para ejecutar comandos arbitrarios en el sistema donde es implementada la aplicaci\u00f3n vulnerable."
    }
  ],
  "id": "CVE-2020-5332",
  "lastModified": "2024-11-21T05:33:55.780",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "SINGLE",
          "availabilityImpact": "COMPLETE",
          "baseScore": 9.0,
          "confidentialityImpact": "COMPLETE",
          "integrityImpact": "COMPLETE",
          "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
          "version": "2.0"
        },
        "exploitabilityScore": 8.0,
        "impactScore": 10.0,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 7.2,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "HIGH",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.2,
        "impactScore": 5.9,
        "source": "security_alert@emc.com",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 7.2,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "HIGH",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.2,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2020-05-04T19:15:13.363",
  "references": [
    {
      "source": "security_alert@emc.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.dell.com/support/security/en-us/details/DOC-111112/DSA-2020-049-RSA-Archer-Security-Update-for-Multiple-Vulnerabilities"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.dell.com/support/security/en-us/details/DOC-111112/DSA-2020-049-RSA-Archer-Security-Update-for-Multiple-Vulnerabilities"
    }
  ],
  "sourceIdentifier": "security_alert@emc.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-78"
        }
      ],
      "source": "security_alert@emc.com",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-78"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.


Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…