FKIE_CVE-2020-7488

Vulnerability from fkie_nvd - Published: 2020-04-22 19:15 - Updated: 2026-06-17 03:24

{
  "affected": [
    {
      "affectedData": [
        {
          "product": "EcoStruxure Machine Expert (all versions)SoMachine, SoMachine Motion (all versions)Modicon M218 Logic Controller (all versions)Modicon M241 Logic Controller (all versions)Modicon M251 Logic Controller (all versions)Modicon M258 Logic Controller (all versions)",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "EcoStruxure Machine Expert (all versions)SoMachine, SoMachine Motion (all versions)Modicon M218 Logic Controller (all versions)Modicon M241 Logic Controller (all versions)Modicon M251 Logic Controller (all versions)Modicon M258 Logic Controller (all versions)"
            }
          ]
        }
      ],
      "source": "cybersecurity@se.com"
    }
  ],
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:schneider-electric:ecostruxure_machine_expert:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E30E4E9A-2FD2-4F8E-B9EE-7771CEB93094",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:schneider-electric:somachine:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "29636208-D72F-493A-A94A-A230AEA8733C",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:schneider-electric:somachine_motion:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D458B41F-DE55-4E06-97FA-E2F7A71C2EAF",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:schneider-electric:modicon_m218_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "59FFF30B-4201-41F0-AAFE-7A8D619805A6",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:schneider-electric:modicon_m218:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "852DBDD1-E960-4D87-9F77-8B8CB94222BB",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:schneider-electric:modicon_m241_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "363D8E9E-0169-472F-A891-EF2E7D329EA2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:schneider-electric:modicon_m241:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4D8FD9D9-F59F-470E-9F7F-CDDD80B0633C",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:schneider-electric:modicon_m251_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "FB11232E-0DC2-436F-985A-94BCE6A4F6D4",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:schneider-electric:modicon_m251:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B8E03A25-B0B6-4BA2-80BC-52C16A6837E0",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:schneider-electric:modicon_m258_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "686716B7-1C82-483C-A62F-A33F7C5BF32F",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:schneider-electric:modicon_m258:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "FFBF6514-3E32-4C8E-81BA-D6464824351F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A CWE-319: Cleartext Transmission of Sensitive Information vulnerability exists which could leak sensitive information transmitted between the software and the Modicon M218, M241, M251, and M258 controllers."
    },
    {
      "lang": "es",
      "value": "CWE-319: Hay una vulnerabilidad de Transmisi\u00f3n de  Informaci\u00f3n Confidencial en Texto Sin Cifrar que podr\u00eda filtrar informaci\u00f3n confidencial transmitida entre el software y los controladores Modicon M218, M241, M251 y M258."
    }
  ],
  "id": "CVE-2020-7488",
  "lastModified": "2026-06-17T03:24:52.740",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "NONE",
          "baseScore": 5.0,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "NONE",
          "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 2.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Primary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 3.6,
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "type": "Secondary"
      }
    ],
    "ssvcV203": [
      {
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "ssvcData": {
          "id": "CVE-2020-7488",
          "options": [
            {
              "exploitation": "none"
            },
            {
              "automatable": "yes"
            },
            {
              "technicalImpact": "partial"
            }
          ],
          "role": "CISA Coordinator",
          "timestamp": "2026-05-28T20:28:35.740115Z",
          "version": "2.0.3"
        }
      }
    ]
  },
  "published": "2020-04-22T19:15:11.717",
  "references": [
    {
      "source": "cybersecurity@se.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.se.com/ww/en/download/document/SEVD-2020-105-02"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.se.com/ww/en/download/document/SEVD-2020-105-02"
    }
  ],
  "sourceIdentifier": "cybersecurity@se.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-319"
        }
      ],
      "source": "cybersecurity@se.com",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-319"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Loading…

Loading…

Related by attack behaviour

Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.


Loading…