FKIE_CVE-2020-7523

Vulnerability from fkie_nvd - Published: 2020-08-31 17:15 - Updated: 2024-11-21 05:37
Summary
Improper Privilege Management vulnerability exists in Schneider Electric Modbus Serial Driver (see security notification for versions) which could cause local privilege escalation when the Modbus Serial Driver service is invoked. The driver does not properly assign, modify, track, or check privileges for an actor, creating an unintended sphere of control for that actor.

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:schneider-electric:modbus_driver_suite:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "105D5959-C658-4129-9723-01CCF48F5BD1",
              "versionEndExcluding": "14.15.0.0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:schneider-electric:modbus_serial_driver:*:*:*:*:*:*:x86:*",
              "matchCriteriaId": "1DA63BCF-FB96-4226-8325-4A38D08F9E3A",
              "versionEndExcluding": "2.20_ie_30",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:schneider-electric:modbus_serial_driver:*:*:*:*:*:*:x64:*",
              "matchCriteriaId": "B242EE94-A9A0-482D-ADB6-D6CC6608703E",
              "versionEndExcluding": "3.20_ie_30",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Improper Privilege Management vulnerability exists in Schneider Electric Modbus Serial Driver (see security notification for versions) which could cause local privilege escalation when the Modbus Serial Driver service is invoked. The driver does not properly assign, modify, track, or check privileges for an actor, creating an unintended sphere of control for that actor."
    },
    {
      "lang": "es",
      "value": "Se presenta una vulnerabilidad de Administraci\u00f3n de Privilegios Inapropiada en Schneider Electric Modbus Serial Driver (consulte la notificaci\u00f3n de seguridad para las versiones) que podr\u00eda causar una escalada de privilegios locales cuando el servicio Modbus Serial Driver es invocado. El controlador no asigna, modifica, rastrea o comprueba apropiadamente los privilegios de un actor, creando una esfera de control no prevista para ese actor"
    }
  ],
  "id": "CVE-2020-7523",
  "lastModified": "2024-11-21T05:37:18.530",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "MEDIUM",
          "accessVector": "LOCAL",
          "authentication": "NONE",
          "availabilityImpact": "PARTIAL",
          "baseScore": 4.4,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:L/AC:M/Au:N/C:P/I:P/A:P",
          "version": "2.0"
        },
        "exploitabilityScore": 3.4,
        "impactScore": 6.4,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "HIGH",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 7.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "scope": "CHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:C/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.1,
        "impactScore": 6.0,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2020-08-31T17:15:12.373",
  "references": [
    {
      "source": "cybersecurity@se.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.se.com/ww/en/download/document/SEVD-2020-224-01/"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.se.com/ww/en/download/document/SEVD-2020-224-01/"
    }
  ],
  "sourceIdentifier": "cybersecurity@se.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-269"
        }
      ],
      "source": "cybersecurity@se.com",
      "type": "Secondary"
    }
  ]
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.


Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…