FKIE_CVE-2021-22713
Vulnerability from fkie_nvd - Published: 2021-03-11 21:15 - Updated: 2024-11-21 05:50
Severity ?
Summary
A CWE-119:Improper restriction of operations within the bounds of a memory buffer vulnerability exists in PowerLogic ION8650, ION8800, ION7650, ION7700/73xx, and ION83xx/84xx/85xx/8600 (see security notifcation for affected versions), which could cause the meter to reboot.
References
Impacted products
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:schneider-electric:powerlogic_ion8650_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "33CD5DAD-BE28-491D-A1CD-09F01194115F",
"versionEndExcluding": "4.40.1",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:schneider-electric:powerlogic_ion8650:-:*:*:*:*:*:*:*",
"matchCriteriaId": "FBC3A306-D4F4-4C2A-9D60-DD8F0826AEEC",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:schneider-electric:powerlogic_ion8800_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "99A58454-5EF2-4CD2-8391-577771573D2D",
"versionEndExcluding": "372",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:schneider-electric:powerlogic_ion8800:-:*:*:*:*:*:*:*",
"matchCriteriaId": "46E8E79E-6DA7-4094-9622-3B91D5913493",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:schneider-electric:powerlogic_ion7550_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "EDE14AD4-32C5-49C3-AB52-223CBC52A146",
"versionEndExcluding": "376",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:schneider-electric:powerlogic_ion7550:4.0:*:*:*:*:*:*:*",
"matchCriteriaId": "4AFA65E4-51D6-4D2A-B750-7099DA03B107",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:schneider-electric:powerlogic_ion7650_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "97910A81-407C-48C4-94AB-585FCCEAA56B",
"versionEndExcluding": "376",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:schneider-electric:powerlogic_ion7650:4.0:*:*:*:*:*:*:*",
"matchCriteriaId": "5CD0CD85-457E-4153-B1C2-1B7D39B5854B",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:schneider-electric:powerlogic_ion7700_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "08CA14DE-656C-4D60-986B-FE149560FC2F",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:schneider-electric:powerlogic_ion7700:-:*:*:*:*:*:*:*",
"matchCriteriaId": "07312E20-FF8A-4BD2-AB8D-AEA01B984AFE",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:schneider-electric:powerlogic_ion7300_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "36D4CF8E-053E-42CD-8A8D-EBCFD52A7266",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:schneider-electric:powerlogic_ion7300:-:*:*:*:*:*:*:*",
"matchCriteriaId": "F527180F-F818-4D4C-A0BF-F10C8B53B9C4",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:schneider-electric:powerlogic_ion8300_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "1047C892-B7F5-49FB-AB36-8E8061A58037",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:schneider-electric:powerlogic_ion8300:-:*:*:*:*:*:*:*",
"matchCriteriaId": "F01E9FE2-4110-4A6D-99F3-49784808D951",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:schneider-electric:powerlogic_ion8400_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "70BAC583-6101-4F26-A264-26E5D69E9188",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:schneider-electric:powerlogic_ion8400:-:*:*:*:*:*:*:*",
"matchCriteriaId": "82527983-6167-4D7B-A70A-D1A814ED3D06",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:schneider-electric:powerlogic_ion8500_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "768FB179-B6D7-457C-9795-310400460F6E",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:schneider-electric:powerlogic_ion8500:-:*:*:*:*:*:*:*",
"matchCriteriaId": "75E37742-CFF9-4F80-9B6A-0D4F5AD23112",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:schneider-electric:powerlogic_ion8600_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "DB6B0276-AB51-4B8F-B2A7-85EDD56C9E7C",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:schneider-electric:powerlogic_ion8600:-:*:*:*:*:*:*:*",
"matchCriteriaId": "324CF58A-753C-4D9C-8E72-FC8EE26EDA0D",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:schneider-electric:powerlogic_ion7550_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "3A481A07-B2B3-4C35-A19F-DF38885664DA",
"versionEndExcluding": "416",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:schneider-electric:powerlogic_ion7550:5.0:*:*:*:*:*:*:*",
"matchCriteriaId": "029ADDBB-8F5D-4981-B23E-1CF7803AB371",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:schneider-electric:ion7650_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "0A099948-C46C-47E9-A457-8CFADDF740BC",
"versionEndExcluding": "416",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:schneider-electric:powerlogic_ion7650:5.0:*:*:*:*:*:*:*",
"matchCriteriaId": "A561E460-E2E7-44EB-9579-51C6715C5F60",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A CWE-119:Improper restriction of operations within the bounds of a memory buffer vulnerability exists in PowerLogic ION8650, ION8800, ION7650, ION7700/73xx, and ION83xx/84xx/85xx/8600 (see security notifcation for affected versions), which could cause the meter to reboot."
},
{
"lang": "es",
"value": "A CWE-119: se presenta vulnerabilidad de Restricci\u00f3n Inapropiada de Operaciones dentro de los L\u00edmites de un B\u00fafer de la Memoria en PowerLogic ION8650, ION8800, ION7650, ION7700 /73xx e ION83xx /84xx/85xx /8600 (consulte la notificaci\u00f3n de seguridad para las versiones afectadas), lo que podr\u00eda causar al medidor reiniciarse"
}
],
"id": "CVE-2021-22713",
"lastModified": "2024-11-21T05:50:30.943",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "HIGH",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "COMPLETE",
"baseScore": 7.8,
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
"version": "2.0"
},
"exploitabilityScore": 10.0,
"impactScore": 6.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 3.6,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2021-03-11T21:15:12.407",
"references": [
{
"source": "cybersecurity@se.com",
"tags": [
"Vendor Advisory"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2021-068-03"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2021-068-03"
}
],
"sourceIdentifier": "cybersecurity@se.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-119"
}
],
"source": "cybersecurity@se.com",
"type": "Secondary"
}
]
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…