GCVE Workshop - 22 September 2026 (14:00-18:00), Luxembourg Before The Vulnopticon Conference - Registration

FKIE_CVE-2023-31173

Vulnerability from fkie_nvd - Published: 2023-08-31 16:15 - Updated: 2026-06-17 05:56
Summary
Use of Hard-coded Credentials vulnerability in Schweitzer Engineering Laboratories SEL-5037 SEL Grid Configurator on Windows allows Authentication Bypass. See Instruction Manual Appendix A and Appendix E dated 20230615 for more details. This issue affects SEL-5037 SEL Grid Configurator: before 4.5.0.20.
Impacted products

{
  "affected": [
    {
      "affectedData": [
        {
          "defaultStatus": "unaffected",
          "platforms": [
            "Windows"
          ],
          "product": "SEL-5037 SEL Grid Configurator",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "4.5.0.20",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "source": "security@selinc.com"
    },
    {
      "affectedData": [
        {
          "cpes": [
            "cpe:2.3:a:schweitzer_engineering_laboratories:sel-5033_acselerator_rtac_software:*:*:*:*:*:*:*:*"
          ],
          "defaultStatus": "unaffected",
          "product": "sel-5033_acselerator_rtac_software",
          "vendor": "schweitzer_engineering_laboratories",
          "versions": [
            {
              "lessThan": "4.5.0.20",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0"
    }
  ],
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:selinc:sel-5037_sel_grid_configurator:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "8DE1284E-619F-49AC-AE96-0A4ECD76292B",
              "versionEndExcluding": "4.5.0.20",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:microsoft:windows:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A2572D17-1DE6-457B-99CC-64AFD54487EA",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Use of Hard-coded Credentials vulnerability in Schweitzer Engineering Laboratories SEL-5037 SEL Grid Configurator on Windows allows Authentication Bypass.\n\n\n\nSee Instruction Manual Appendix A and Appendix E dated 20230615 for more details.\n\n\nThis issue affects SEL-5037 SEL Grid Configurator: before 4.5.0.20.\n\n"
    },
    {
      "lang": "es",
      "value": "La vulnerabilidad de credenciales codificadas en Schweitzer Engineering Laboratories SEL-5037 SEL Grid Configurator en Windows permite la omisi\u00f3n de autenticaci\u00f3n.\n\nConsulte el Manual de instrucciones Ap\u00e9ndice A y Ap\u00e9ndice E con fecha 20230615 para m\u00e1s detalles.\n\nEste problema afecta a SEL-5037 SEL Grid Configurator: anterior a la versi\u00f3n 4.5.0.20."
    }
  ],
  "id": "CVE-2023-31173",
  "lastModified": "2026-06-17T05:56:27.920",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "NONE",
          "baseScore": 7.7,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 2.5,
        "impactScore": 5.2,
        "source": "security@selinc.com",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 8.4,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 2.5,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ],
    "ssvcV203": [
      {
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "ssvcData": {
          "id": "CVE-2023-31173",
          "options": [
            {
              "exploitation": "none"
            },
            {
              "automatable": "no"
            },
            {
              "technicalImpact": "total"
            }
          ],
          "role": "CISA Coordinator",
          "timestamp": "2024-10-01T17:20:11.993761Z",
          "version": "2.0.3"
        }
      }
    ]
  },
  "published": "2023-08-31T16:15:09.567",
  "references": [
    {
      "source": "security@selinc.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://selinc.com/support/security-notifications/external-reports/"
    },
    {
      "source": "security@selinc.com",
      "tags": [
        "Not Applicable"
      ],
      "url": "https://www.nozominetworks.com/blog/"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://selinc.com/support/security-notifications/external-reports/"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Not Applicable"
      ],
      "url": "https://www.nozominetworks.com/blog/"
    }
  ],
  "sourceIdentifier": "security@selinc.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-798"
        }
      ],
      "source": "security@selinc.com",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-798"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…

Related by attack behaviour

Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.


Loading…