FKIE_CVE-2024-42427

Vulnerability from fkie_nvd - Published: 2024-09-10 08:15 - Updated: 2024-12-20 14:43
Summary
Dell ThinOS versions 2402 and 2405, contains an Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability. An unauthenticated attacker with physical access could potentially exploit this vulnerability, leading to Elevation of privileges.
Impacted products
Vendor Product Version
dell wyse_thinos 9.5.1079
dell wyse_thinos 9.5.2109

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:dell:wyse_thinos:9.5.1079:*:*:*:*:*:*:*",
              "matchCriteriaId": "4912456C-F4B9-4B5E-82DC-BA3BB28456A5",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:dell:wyse_thinos:9.5.2109:*:*:*:*:*:*:*",
              "matchCriteriaId": "62BCEB7B-BC2B-4DB3-8D70-16E67D63EE2E",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Dell ThinOS versions 2402 and 2405, contains an Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027) vulnerability. An unauthenticated attacker with physical access could potentially exploit this vulnerability, leading to Elevation of privileges."
    },
    {
      "lang": "es",
      "value": "Las versiones 2402 y 2405 de Dell ThinOS contienen una vulnerabilidad de neutralizaci\u00f3n inadecuada de elementos especiales utilizados en un comando (\u0027inyecci\u00f3n de comando\u0027). Un atacante no autenticado con acceso f\u00edsico podr\u00eda aprovechar esta vulnerabilidad, lo que provocar\u00eda una elevaci\u00f3n de privilegios."
    }
  ],
  "id": "CVE-2024-42427",
  "lastModified": "2024-12-20T14:43:52.363",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "PHYSICAL",
          "availabilityImpact": "HIGH",
          "baseScore": 7.6,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "CHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 0.9,
        "impactScore": 6.0,
        "source": "security_alert@emc.com",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "PHYSICAL",
          "availabilityImpact": "HIGH",
          "baseScore": 7.6,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "CHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 0.9,
        "impactScore": 6.0,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2024-09-10T08:15:02.760",
  "references": [
    {
      "source": "security_alert@emc.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.dell.com/support/kbdoc/en-us/000228350/dsa-2024-386"
    }
  ],
  "sourceIdentifier": "security_alert@emc.com",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-77"
        }
      ],
      "source": "security_alert@emc.com",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-77"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.


Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…