FKIE_CVE-2024-8306
Vulnerability from fkie_nvd - Published: 2024-09-11 15:15 - Updated: 2024-09-18 19:51
Severity ?
7.8 (High) - CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
7.8 (High) - CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
7.8 (High) - CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Summary
CWE-269: Improper Privilege Management vulnerability exists that could cause unauthorized
access, loss of confidentiality, integrity and availability of the workstation when non-admin
authenticated user tries to perform privilege escalation by tampering with the binaries.
References
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| schneider-electric | vijeo_designer | * | |
| schneider-electric | vijeo_designer | 6.3 | |
| schneider-electric | vijeo_designer_embedded_in_ecostruxure_machine_expert | * |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:schneider-electric:vijeo_designer:*:*:*:*:*:*:*:*",
"matchCriteriaId": "F4501EC7-939C-4E71-A5D3-3F1112D39190",
"versionEndExcluding": "6.3",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:schneider-electric:vijeo_designer:6.3:-:*:*:*:*:*:*",
"matchCriteriaId": "204A592B-1B28-43FC-878F-559BDF5A7944",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:schneider-electric:vijeo_designer_embedded_in_ecostruxure_machine_expert:*:*:*:*:*:*:*:*",
"matchCriteriaId": "99EBBD6F-0C97-493A-B708-60DD27733247",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "CWE-269: Improper Privilege Management vulnerability exists that could cause unauthorized\naccess, loss of confidentiality, integrity and availability of the workstation when non-admin\nauthenticated user tries to perform privilege escalation by tampering with the binaries."
},
{
"lang": "es",
"value": "CWE-269: Existe una vulnerabilidad de administraci\u00f3n inadecuada de privilegios que podr\u00eda causar acceso no autorizado, p\u00e9rdida de confidencialidad, integridad y disponibilidad de la estaci\u00f3n de trabajo cuando un usuario autenticado que no es administrador intenta realizar una escalada de privilegios alterando los binarios."
}
],
"id": "CVE-2024-8306",
"lastModified": "2024-09-18T19:51:14.850",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 1.8,
"impactScore": 5.9,
"source": "cybersecurity@se.com",
"type": "Secondary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 1.8,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2024-09-11T15:15:18.827",
"references": [
{
"source": "cybersecurity@se.com",
"tags": [
"Vendor Advisory"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-254-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-254-01.pdf"
}
],
"sourceIdentifier": "cybersecurity@se.com",
"vulnStatus": "Analyzed",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-269"
}
],
"source": "cybersecurity@se.com",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "NVD-CWE-noinfo"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.