GHSA-PQR7-274X-7PXJ
Vulnerability from github – Published: 2022-05-24 17:42 – Updated: 2022-05-24 17:42A vulnerability in ICMP Version 6 (ICMPv6) processing in Cisco NX-OS Software could allow an unauthenticated, remote attacker to cause a slow system memory leak, which over time could lead to a denial of service (DoS) condition. This vulnerability is due to improper error handling when an IPv6-configured interface receives a specific type of ICMPv6 packet. An attacker could exploit this vulnerability by sending a sustained rate of crafted ICMPv6 packets to a local IPv6 address on a targeted device. A successful exploit could allow the attacker to cause a system memory leak in the ICMPv6 process on the device. As a result, the ICMPv6 process could run out of system memory and stop processing traffic. The device could then drop all ICMPv6 packets, causing traffic instability on the device. Restoring device functionality would require a device reboot.
{
"affected": [],
"aliases": [
"CVE-2021-1229"
],
"database_specific": {
"cwe_ids": [
"CWE-401"
],
"github_reviewed": false,
"github_reviewed_at": null,
"nvd_published_at": "2021-02-24T20:15:00Z",
"severity": "MODERATE"
},
"details": "A vulnerability in ICMP Version 6 (ICMPv6) processing in Cisco NX-OS Software could allow an unauthenticated, remote attacker to cause a slow system memory leak, which over time could lead to a denial of service (DoS) condition. This vulnerability is due to improper error handling when an IPv6-configured interface receives a specific type of ICMPv6 packet. An attacker could exploit this vulnerability by sending a sustained rate of crafted ICMPv6 packets to a local IPv6 address on a targeted device. A successful exploit could allow the attacker to cause a system memory leak in the ICMPv6 process on the device. As a result, the ICMPv6 process could run out of system memory and stop processing traffic. The device could then drop all ICMPv6 packets, causing traffic instability on the device. Restoring device functionality would require a device reboot.",
"id": "GHSA-pqr7-274x-7pxj",
"modified": "2022-05-24T17:42:59Z",
"published": "2022-05-24T17:42:59Z",
"references": [
{
"type": "ADVISORY",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2021-1229"
},
{
"type": "WEB",
"url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-fxos-nxos-icmpv6-dos-YD55jVCq"
}
],
"schema_version": "1.4.0",
"severity": []
}
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.