GHSA-QG8X-2GCC-V7RF
Vulnerability from github – Published: 2023-02-23 21:30 – Updated: 2023-03-08 00:30A vulnerability in the Link Layer Discovery Protocol (LLDP) feature for Cisco Nexus 9000 Series Fabric Switches in Application Centric Infrastructure (ACI) Mode could allow an unauthenticated, adjacent attacker to cause a memory leak, which could result in an unexpected reload of the device. This vulnerability is due to incorrect error checking when parsing ingress LLDP packets. An attacker could exploit this vulnerability by sending a steady stream of crafted LLDP packets to an affected device. A successful exploit could allow the attacker to cause a memory leak, which could result in a denial of service (DoS) condition when the device unexpectedly reloads. Note: This vulnerability cannot be exploited by transit traffic through the device. The crafted LLDP packet must be targeted to a directly connected interface, and the attacker must be in the same broadcast domain as the affected device (Layer 2 adjacent). In addition, the attack surface for this vulnerability can be reduced by disabling LLDP on interfaces where it is not required.
{
"affected": [],
"aliases": [
"CVE-2023-20089"
],
"database_specific": {
"cwe_ids": [
"CWE-401"
],
"github_reviewed": false,
"github_reviewed_at": null,
"nvd_published_at": "2023-02-23T20:15:00Z",
"severity": "MODERATE"
},
"details": "A vulnerability in the Link Layer Discovery Protocol (LLDP) feature for Cisco Nexus 9000 Series Fabric Switches in Application Centric Infrastructure (ACI) Mode could allow an unauthenticated, adjacent attacker to cause a memory leak, which could result in an unexpected reload of the device. This vulnerability is due to incorrect error checking when parsing ingress LLDP packets. An attacker could exploit this vulnerability by sending a steady stream of crafted LLDP packets to an affected device. A successful exploit could allow the attacker to cause a memory leak, which could result in a denial of service (DoS) condition when the device unexpectedly reloads. Note: This vulnerability cannot be exploited by transit traffic through the device. The crafted LLDP packet must be targeted to a directly connected interface, and the attacker must be in the same broadcast domain as the affected device (Layer 2 adjacent). In addition, the attack surface for this vulnerability can be reduced by disabling LLDP on interfaces where it is not required.",
"id": "GHSA-qg8x-2gcc-v7rf",
"modified": "2023-03-08T00:30:34Z",
"published": "2023-02-23T21:30:16Z",
"references": [
{
"type": "ADVISORY",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2023-20089"
},
{
"type": "WEB",
"url": "https://sec.cloudapps.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-aci-lldp-dos-ySCNZOpX"
}
],
"schema_version": "1.4.0",
"severity": [
{
"score": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"type": "CVSS_V3"
}
]
}
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.