gsd-2019-1608
Vulnerability from gsd
Modified
2023-12-13 01:23
Details
A vulnerability in the CLI of Cisco NX-OS Software could allow an authenticated, local attacker to execute arbitrary commands on the underlying operating system of an affected device. The vulnerability is due to insufficient validation of arguments passed to certain CLI commands. An attacker could exploit this vulnerability by including malicious input as the argument of an affected command. A successful exploit could allow the attacker to execute arbitrary commands on the underlying operating system with elevated privileges. An attacker would need valid administrator credentials to exploit this vulnerability. MDS 9000 Series Multilayer Switches are affected in versions prior to 6.2(27), 8.1(1b), and 8.3(1). Nexus 7000 and 7700 Series Switches are affected in versions prior to 6.2(22), 7.3(3)D1(1), and 8.2(3).
Aliases
Aliases



{
  "GSD": {
    "alias": "CVE-2019-1608",
    "description": "A vulnerability in the CLI of Cisco NX-OS Software could allow an authenticated, local attacker to execute arbitrary commands on the underlying operating system of an affected device. The vulnerability is due to insufficient validation of arguments passed to certain CLI commands. An attacker could exploit this vulnerability by including malicious input as the argument of an affected command. A successful exploit could allow the attacker to execute arbitrary commands on the underlying operating system with elevated privileges. An attacker would need valid administrator credentials to exploit this vulnerability. MDS 9000 Series Multilayer Switches are affected in versions prior to 6.2(27), 8.1(1b), and 8.3(1). Nexus 7000 and 7700 Series Switches are affected in versions prior to 6.2(22), 7.3(3)D1(1), and 8.2(3).",
    "id": "GSD-2019-1608"
  },
  "gsd": {
    "metadata": {
      "exploitCode": "unknown",
      "remediation": "unknown",
      "reportConfidence": "confirmed",
      "type": "vulnerability"
    },
    "osvSchema": {
      "aliases": [
        "CVE-2019-1608"
      ],
      "details": "A vulnerability in the CLI of Cisco NX-OS Software could allow an authenticated, local attacker to execute arbitrary commands on the underlying operating system of an affected device. The vulnerability is due to insufficient validation of arguments passed to certain CLI commands. An attacker could exploit this vulnerability by including malicious input as the argument of an affected command. A successful exploit could allow the attacker to execute arbitrary commands on the underlying operating system with elevated privileges. An attacker would need valid administrator credentials to exploit this vulnerability. MDS 9000 Series Multilayer Switches are affected in versions prior to 6.2(27), 8.1(1b), and 8.3(1). Nexus 7000 and 7700 Series Switches are affected in versions prior to 6.2(22), 7.3(3)D1(1), and 8.2(3).",
      "id": "GSD-2019-1608",
      "modified": "2023-12-13T01:23:51.570891Z",
      "schema_version": "1.4.0"
    }
  },
  "namespaces": {
    "cve.org": {
      "CVE_data_meta": {
        "ASSIGNER": "psirt@cisco.com",
        "DATE_PUBLIC": "2019-03-06T16:00:00-0800",
        "ID": "CVE-2019-1608",
        "STATE": "PUBLIC",
        "TITLE": "Cisco NX-OS Software CLI Command Injection Vulnerability (CVE-2019-1608)"
      },
      "affects": {
        "vendor": {
          "vendor_data": [
            {
              "product": {
                "product_data": [
                  {
                    "product_name": "MDS 9000 Series Multilayer Switches",
                    "version": {
                      "version_data": [
                        {
                          "affected": "\u003c",
                          "version_value": "6.2(27)"
                        },
                        {
                          "affected": "\u003c",
                          "version_value": "8.1(1b)"
                        },
                        {
                          "affected": "\u003c",
                          "version_value": "8.3(1)"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "Nexus 7000 and 7700 Series Switches",
                    "version": {
                      "version_data": [
                        {
                          "affected": "\u003c",
                          "version_value": "6.2(22)"
                        },
                        {
                          "affected": "\u003c",
                          "version_value": "7.3(3)D1(1)"
                        },
                        {
                          "affected": "\u003c",
                          "version_value": "8.2(3)"
                        }
                      ]
                    }
                  }
                ]
              },
              "vendor_name": "Cisco"
            }
          ]
        }
      },
      "data_format": "MITRE",
      "data_type": "CVE",
      "data_version": "4.0",
      "description": {
        "description_data": [
          {
            "lang": "eng",
            "value": "A vulnerability in the CLI of Cisco NX-OS Software could allow an authenticated, local attacker to execute arbitrary commands on the underlying operating system of an affected device. The vulnerability is due to insufficient validation of arguments passed to certain CLI commands. An attacker could exploit this vulnerability by including malicious input as the argument of an affected command. A successful exploit could allow the attacker to execute arbitrary commands on the underlying operating system with elevated privileges. An attacker would need valid administrator credentials to exploit this vulnerability. MDS 9000 Series Multilayer Switches are affected in versions prior to 6.2(27), 8.1(1b), and 8.3(1). Nexus 7000 and 7700 Series Switches are affected in versions prior to 6.2(22), 7.3(3)D1(1), and 8.2(3)."
          }
        ]
      },
      "exploit": [
        {
          "lang": "eng",
          "value": "The Cisco Product Security Incident Response Team (PSIRT) is not aware of any public announcements or malicious use of the vulnerability that is described in this advisory. "
        }
      ],
      "impact": {
        "cvss": {
          "baseScore": "4.2",
          "vectorString": "CVSS:3.0/AV:L/AC:L/PR:H/UI:N/S:U/C:L/I:L/A:L ",
          "version": "3.0"
        }
      },
      "problemtype": {
        "problemtype_data": [
          {
            "description": [
              {
                "lang": "eng",
                "value": "CWE-77"
              }
            ]
          }
        ]
      },
      "references": {
        "reference_data": [
          {
            "name": "107386",
            "refsource": "BID",
            "url": "http://www.securityfocus.com/bid/107386"
          },
          {
            "name": "20190306 Cisco NX-OS Software CLI Command Injection Vulnerability (CVE-2019-1608)",
            "refsource": "CISCO",
            "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20190306-nxos-cmdinj-1608"
          }
        ]
      },
      "source": {
        "advisory": "cisco-sa-20190306-nxos-cmdinj-1608",
        "defect": [
          [
            "CSCvi01422"
          ]
        ],
        "discovery": "INTERNAL"
      }
    },
    "nvd.nist.gov": {
      "configurations": {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:cisco:nx-os:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "8.3\\(1\\)",
                    "versionStartIncluding": "8.2",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:cisco:mds_9000:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:cisco:nx-os:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "8.1\\(1b\\)",
                    "versionStartIncluding": "7.3",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:cisco:mds_9000:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:cisco:nx-os:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "6.2\\(27\\)",
                    "versionStartIncluding": "5.2",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:cisco:mds_9000:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:cisco:nx-os:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "8.2\\(3\\)",
                    "versionStartExcluding": "8.0",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:cisco:nexus_7700:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  },
                  {
                    "cpe23Uri": "cpe:2.3:h:cisco:nexus_7000:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:cisco:nx-os:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "7.3\\(3\\)d1\\(1\\)",
                    "versionStartExcluding": "7.2",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:cisco:nexus_7700:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  },
                  {
                    "cpe23Uri": "cpe:2.3:h:cisco:nexus_7000:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:cisco:nx-os:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "6.2\\(22\\)",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:cisco:nexus_7000:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  },
                  {
                    "cpe23Uri": "cpe:2.3:h:cisco:nexus_7700:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          }
        ]
      },
      "cve": {
        "CVE_data_meta": {
          "ASSIGNER": "psirt@cisco.com",
          "ID": "CVE-2019-1608"
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "en",
              "value": "A vulnerability in the CLI of Cisco NX-OS Software could allow an authenticated, local attacker to execute arbitrary commands on the underlying operating system of an affected device. The vulnerability is due to insufficient validation of arguments passed to certain CLI commands. An attacker could exploit this vulnerability by including malicious input as the argument of an affected command. A successful exploit could allow the attacker to execute arbitrary commands on the underlying operating system with elevated privileges. An attacker would need valid administrator credentials to exploit this vulnerability. MDS 9000 Series Multilayer Switches are affected in versions prior to 6.2(27), 8.1(1b), and 8.3(1). Nexus 7000 and 7700 Series Switches are affected in versions prior to 6.2(22), 7.3(3)D1(1), and 8.2(3)."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "en",
                  "value": "CWE-88"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "20190306 Cisco NX-OS Software CLI Command Injection Vulnerability (CVE-2019-1608)",
              "refsource": "CISCO",
              "tags": [
                "Vendor Advisory"
              ],
              "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20190306-nxos-cmdinj-1608"
            },
            {
              "name": "107386",
              "refsource": "BID",
              "tags": [
                "Third Party Advisory",
                "VDB Entry"
              ],
              "url": "http://www.securityfocus.com/bid/107386"
            }
          ]
        }
      },
      "impact": {
        "baseMetricV2": {
          "acInsufInfo": false,
          "cvssV2": {
            "accessComplexity": "LOW",
            "accessVector": "LOCAL",
            "authentication": "NONE",
            "availabilityImpact": "COMPLETE",
            "baseScore": 7.2,
            "confidentialityImpact": "COMPLETE",
            "integrityImpact": "COMPLETE",
            "vectorString": "AV:L/AC:L/Au:N/C:C/I:C/A:C",
            "version": "2.0"
          },
          "exploitabilityScore": 3.9,
          "impactScore": 10.0,
          "obtainAllPrivilege": false,
          "obtainOtherPrivilege": false,
          "obtainUserPrivilege": false,
          "severity": "HIGH",
          "userInteractionRequired": false
        },
        "baseMetricV3": {
          "cvssV3": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 6.7,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "exploitabilityScore": 0.8,
          "impactScore": 5.9
        }
      },
      "lastModifiedDate": "2020-10-05T19:51Z",
      "publishedDate": "2019-03-08T20:29Z"
    }
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading...

Loading...

Loading...

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.