gsd-2019-1732
Vulnerability from gsd
Modified
2023-12-13 01:23
Details
A vulnerability in the Remote Package Manager (RPM) subsystem of Cisco NX-OS Software could allow an authenticated, local attacker with administrator credentials to leverage a time-of-check, time-of-use (TOCTOU) race condition to corrupt local variables, which could lead to arbitrary command injection. The vulnerability is due to the lack of a proper locking mechanism on critical variables that need to stay static until used. An attacker could exploit this vulnerability by authenticating to an affected device and issuing a set of RPM-related CLI commands. A successful exploit could allow the attacker to perform arbitrary command injection. The attacker would need administrator credentials for the targeted device.
Aliases
Aliases



{
  "GSD": {
    "alias": "CVE-2019-1732",
    "description": "A vulnerability in the Remote Package Manager (RPM) subsystem of Cisco NX-OS Software could allow an authenticated, local attacker with administrator credentials to leverage a time-of-check, time-of-use (TOCTOU) race condition to corrupt local variables, which could lead to arbitrary command injection. The vulnerability is due to the lack of a proper locking mechanism on critical variables that need to stay static until used. An attacker could exploit this vulnerability by authenticating to an affected device and issuing a set of RPM-related CLI commands. A successful exploit could allow the attacker to perform arbitrary command injection. The attacker would need administrator credentials for the targeted device.",
    "id": "GSD-2019-1732"
  },
  "gsd": {
    "metadata": {
      "exploitCode": "unknown",
      "remediation": "unknown",
      "reportConfidence": "confirmed",
      "type": "vulnerability"
    },
    "osvSchema": {
      "aliases": [
        "CVE-2019-1732"
      ],
      "details": "A vulnerability in the Remote Package Manager (RPM) subsystem of Cisco NX-OS Software could allow an authenticated, local attacker with administrator credentials to leverage a time-of-check, time-of-use (TOCTOU) race condition to corrupt local variables, which could lead to arbitrary command injection. The vulnerability is due to the lack of a proper locking mechanism on critical variables that need to stay static until used. An attacker could exploit this vulnerability by authenticating to an affected device and issuing a set of RPM-related CLI commands. A successful exploit could allow the attacker to perform arbitrary command injection. The attacker would need administrator credentials for the targeted device.",
      "id": "GSD-2019-1732",
      "modified": "2023-12-13T01:23:51.368583Z",
      "schema_version": "1.4.0"
    }
  },
  "namespaces": {
    "cve.org": {
      "CVE_data_meta": {
        "ASSIGNER": "psirt@cisco.com",
        "DATE_PUBLIC": "2019-05-15T16:00:00-0700",
        "ID": "CVE-2019-1732",
        "STATE": "PUBLIC",
        "TITLE": "Cisco NX-OS Software Remote Package Manager Command Injection Vulnerability"
      },
      "affects": {
        "vendor": {
          "vendor_data": [
            {
              "product": {
                "product_data": [
                  {
                    "product_name": "Cisco NX-OS Software",
                    "version": {
                      "version_data": [
                        {
                          "affected": "\u003c",
                          "version_value": "8.3(1)"
                        }
                      ]
                    }
                  }
                ]
              },
              "vendor_name": "Cisco"
            }
          ]
        }
      },
      "data_format": "MITRE",
      "data_type": "CVE",
      "data_version": "4.0",
      "description": {
        "description_data": [
          {
            "lang": "eng",
            "value": "A vulnerability in the Remote Package Manager (RPM) subsystem of Cisco NX-OS Software could allow an authenticated, local attacker with administrator credentials to leverage a time-of-check, time-of-use (TOCTOU) race condition to corrupt local variables, which could lead to arbitrary command injection. The vulnerability is due to the lack of a proper locking mechanism on critical variables that need to stay static until used. An attacker could exploit this vulnerability by authenticating to an affected device and issuing a set of RPM-related CLI commands. A successful exploit could allow the attacker to perform arbitrary command injection. The attacker would need administrator credentials for the targeted device."
          }
        ]
      },
      "exploit": [
        {
          "lang": "eng",
          "value": "The Cisco Product Security Incident Response Team (PSIRT) is not aware of any public announcements or malicious use of the vulnerability that is described in this advisory. "
        }
      ],
      "impact": {
        "cvss": {
          "baseScore": "6.4",
          "vectorString": "CVSS:3.0/AV:L/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H ",
          "version": "3.0"
        }
      },
      "problemtype": {
        "problemtype_data": [
          {
            "description": [
              {
                "lang": "eng",
                "value": "CWE-78"
              }
            ]
          }
        ]
      },
      "references": {
        "reference_data": [
          {
            "name": "20190515 Cisco NX-OS Software Remote Package Manager Command Injection Vulnerability",
            "refsource": "CISCO",
            "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20190515-nxos-rpm-injec"
          },
          {
            "name": "108361",
            "refsource": "BID",
            "url": "http://www.securityfocus.com/bid/108361"
          }
        ]
      },
      "source": {
        "advisory": "cisco-sa-20190515-nxos-rpm-injec",
        "defect": [
          [
            "CSCvi01453",
            "CSCvj00550"
          ]
        ],
        "discovery": "INTERNAL"
      }
    },
    "nvd.nist.gov": {
      "configurations": {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:cisco:nx-os:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "7.0\\(3\\)i7\\(4\\)",
                    "versionStartIncluding": "7.0\\(3\\)i4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:cisco:nexus_3400:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  },
                  {
                    "cpe23Uri": "cpe:2.3:h:cisco:nexus_3524-x:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  },
                  {
                    "cpe23Uri": "cpe:2.3:h:cisco:nexus_9200:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  },
                  {
                    "cpe23Uri": "cpe:2.3:h:cisco:nexus_9500:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  },
                  {
                    "cpe23Uri": "cpe:2.3:h:cisco:nexus_3524-xl:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  },
                  {
                    "cpe23Uri": "cpe:2.3:h:cisco:nexus_3548-x:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  },
                  {
                    "cpe23Uri": "cpe:2.3:h:cisco:nexus_3548-xl:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  },
                  {
                    "cpe23Uri": "cpe:2.3:h:cisco:nexus_9000:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  },
                  {
                    "cpe23Uri": "cpe:2.3:h:cisco:nexus_3000:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  },
                  {
                    "cpe23Uri": "cpe:2.3:h:cisco:nexus_3100:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  },
                  {
                    "cpe23Uri": "cpe:2.3:h:cisco:nexus_3100-z:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  },
                  {
                    "cpe23Uri": "cpe:2.3:h:cisco:nexus_3100v:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  },
                  {
                    "cpe23Uri": "cpe:2.3:h:cisco:nexus_3200:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  },
                  {
                    "cpe23Uri": "cpe:2.3:h:cisco:nexus_3500:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  },
                  {
                    "cpe23Uri": "cpe:2.3:h:cisco:nexus_9300:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:cisco:nx_os:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "7.0\\(3\\)f3\\(5\\)",
                    "versionStartIncluding": "7.0\\(3\\)",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:cisco:nexus_3600:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          }
        ]
      },
      "cve": {
        "CVE_data_meta": {
          "ASSIGNER": "psirt@cisco.com",
          "ID": "CVE-2019-1732"
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "en",
              "value": "A vulnerability in the Remote Package Manager (RPM) subsystem of Cisco NX-OS Software could allow an authenticated, local attacker with administrator credentials to leverage a time-of-check, time-of-use (TOCTOU) race condition to corrupt local variables, which could lead to arbitrary command injection. The vulnerability is due to the lack of a proper locking mechanism on critical variables that need to stay static until used. An attacker could exploit this vulnerability by authenticating to an affected device and issuing a set of RPM-related CLI commands. A successful exploit could allow the attacker to perform arbitrary command injection. The attacker would need administrator credentials for the targeted device."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "en",
                  "value": "CWE-667"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "20190515 Cisco NX-OS Software Remote Package Manager Command Injection Vulnerability",
              "refsource": "CISCO",
              "tags": [
                "Vendor Advisory"
              ],
              "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20190515-nxos-rpm-injec"
            },
            {
              "name": "108361",
              "refsource": "BID",
              "tags": [
                "Third Party Advisory",
                "VDB Entry"
              ],
              "url": "http://www.securityfocus.com/bid/108361"
            }
          ]
        }
      },
      "impact": {
        "baseMetricV2": {
          "acInsufInfo": false,
          "cvssV2": {
            "accessComplexity": "MEDIUM",
            "accessVector": "LOCAL",
            "authentication": "NONE",
            "availabilityImpact": "COMPLETE",
            "baseScore": 6.9,
            "confidentialityImpact": "COMPLETE",
            "integrityImpact": "COMPLETE",
            "vectorString": "AV:L/AC:M/Au:N/C:C/I:C/A:C",
            "version": "2.0"
          },
          "exploitabilityScore": 3.4,
          "impactScore": 10.0,
          "obtainAllPrivilege": false,
          "obtainOtherPrivilege": false,
          "obtainUserPrivilege": false,
          "severity": "MEDIUM",
          "userInteractionRequired": false
        },
        "baseMetricV3": {
          "cvssV3": {
            "attackComplexity": "HIGH",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 6.4,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "exploitabilityScore": 0.5,
          "impactScore": 5.9
        }
      },
      "lastModifiedDate": "2021-11-03T15:23Z",
      "publishedDate": "2019-05-15T17:29Z"
    }
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading...

Loading...

Loading...

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.