GSD-2019-1885
Vulnerability from gsd - Updated: 2023-12-13 01:23Details
A vulnerability in the Redfish protocol of Cisco Integrated Management Controller (IMC) could allow an authenticated, remote attacker to inject and execute arbitrary commands with root privileges on an affected device. The vulnerability is due to insufficient validation of user-supplied input by the affected software. An attacker could exploit this vulnerability by sending crafted authenticated commands to the web-based management interface of the affected software. A successful exploit could allow the attacker to inject and execute arbitrary commands on an affected device with root privileges.
Aliases
Aliases
{
"GSD": {
"alias": "CVE-2019-1885",
"description": "A vulnerability in the Redfish protocol of Cisco Integrated Management Controller (IMC) could allow an authenticated, remote attacker to inject and execute arbitrary commands with root privileges on an affected device. The vulnerability is due to insufficient validation of user-supplied input by the affected software. An attacker could exploit this vulnerability by sending crafted authenticated commands to the web-based management interface of the affected software. A successful exploit could allow the attacker to inject and execute arbitrary commands on an affected device with root privileges.",
"id": "GSD-2019-1885"
},
"gsd": {
"metadata": {
"exploitCode": "unknown",
"remediation": "unknown",
"reportConfidence": "confirmed",
"type": "vulnerability"
},
"osvSchema": {
"aliases": [
"CVE-2019-1885"
],
"details": "A vulnerability in the Redfish protocol of Cisco Integrated Management Controller (IMC) could allow an authenticated, remote attacker to inject and execute arbitrary commands with root privileges on an affected device. The vulnerability is due to insufficient validation of user-supplied input by the affected software. An attacker could exploit this vulnerability by sending crafted authenticated commands to the web-based management interface of the affected software. A successful exploit could allow the attacker to inject and execute arbitrary commands on an affected device with root privileges.",
"id": "GSD-2019-1885",
"modified": "2023-12-13T01:23:51.740346Z",
"schema_version": "1.4.0"
}
},
"namespaces": {
"cve.org": {
"CVE_data_meta": {
"ASSIGNER": "psirt@cisco.com",
"DATE_PUBLIC": "2019-08-21T16:00:00-0700",
"ID": "CVE-2019-1885",
"STATE": "PUBLIC",
"TITLE": "Cisco Integrated Management Controller Command Injection Vulnerability"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Cisco Unified Computing System (Management Software) ",
"version": {
"version_data": [
{
"affected": "\u003c",
"version_value": "3.0(4k)"
}
]
}
}
]
},
"vendor_name": "Cisco"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability in the Redfish protocol of Cisco Integrated Management Controller (IMC) could allow an authenticated, remote attacker to inject and execute arbitrary commands with root privileges on an affected device. The vulnerability is due to insufficient validation of user-supplied input by the affected software. An attacker could exploit this vulnerability by sending crafted authenticated commands to the web-based management interface of the affected software. A successful exploit could allow the attacker to inject and execute arbitrary commands on an affected device with root privileges."
}
]
},
"exploit": [
{
"lang": "eng",
"value": "The Cisco Product Security Incident Response Team (PSIRT) is not aware of any public announcements or malicious use of the vulnerability that is described in this advisory. "
}
],
"impact": {
"cvss": {
"baseScore": "7.2",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H ",
"version": "3.0"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-78"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "20190821 Cisco Integrated Management Controller Command Injection Vulnerability",
"refsource": "CISCO",
"url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20190821-ucs-cimc"
}
]
},
"source": {
"advisory": "cisco-sa-20190821-ucs-cimc",
"defect": [
[
"CSCvo01180"
]
],
"discovery": "INTERNAL"
}
},
"nvd.nist.gov": {
"configurations": {
"CVE_data_version": "4.0",
"nodes": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:a:cisco:unified_computing_system:4.0\\(1c\\)hs3:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:a:cisco:integrated_management_controller_supervisor:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "3.0\\(4k\\)",
"versionStartIncluding": "3.0.0.0",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:cisco:integrated_management_controller_supervisor:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "4.0\\(4b\\)",
"versionStartIncluding": "4.0.0.0",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:cisco:ucs_c125_m5:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
},
{
"cpe23Uri": "cpe:2.3:h:cisco:ucs_c4200:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
},
{
"cpe23Uri": "cpe:2.3:h:cisco:ucs_s3260:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:a:cisco:integrated_management_controller_supervisor:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "4.0\\(2f\\)",
"versionStartIncluding": "4.0.0.0",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:cisco:ucs_c125_m5:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
},
{
"cpe23Uri": "cpe:2.3:h:cisco:ucs_c4200:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
},
{
"cpe23Uri": "cpe:2.3:h:cisco:ucs_s3260:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
}
]
},
"cve": {
"CVE_data_meta": {
"ASSIGNER": "psirt@cisco.com",
"ID": "CVE-2019-1885"
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "en",
"value": "A vulnerability in the Redfish protocol of Cisco Integrated Management Controller (IMC) could allow an authenticated, remote attacker to inject and execute arbitrary commands with root privileges on an affected device. The vulnerability is due to insufficient validation of user-supplied input by the affected software. An attacker could exploit this vulnerability by sending crafted authenticated commands to the web-based management interface of the affected software. A successful exploit could allow the attacker to inject and execute arbitrary commands on an affected device with root privileges."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "en",
"value": "CWE-78"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "20190821 Cisco Integrated Management Controller Command Injection Vulnerability",
"refsource": "CISCO",
"tags": [
"Vendor Advisory"
],
"url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20190821-ucs-cimc"
}
]
}
},
"impact": {
"baseMetricV2": {
"acInsufInfo": false,
"cvssV2": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"availabilityImpact": "COMPLETE",
"baseScore": 9.0,
"confidentialityImpact": "COMPLETE",
"integrityImpact": "COMPLETE",
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
},
"exploitabilityScore": 8.0,
"impactScore": 10.0,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "HIGH",
"userInteractionRequired": false
},
"baseMetricV3": {
"cvssV3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 1.2,
"impactScore": 5.9
}
},
"lastModifiedDate": "2023-03-31T15:57Z",
"publishedDate": "2019-08-21T19:15Z"
}
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…