gsd-2019-1890
Vulnerability from gsd
Modified
2023-12-13 01:23
Details
A vulnerability in the fabric infrastructure VLAN connection establishment of the Cisco Nexus 9000 Series Application Centric Infrastructure (ACI) Mode Switch Software could allow an unauthenticated, adjacent attacker to bypass security validations and connect an unauthorized server to the infrastructure VLAN. The vulnerability is due to insufficient security requirements during the Link Layer Discovery Protocol (LLDP) setup phase of the infrastructure VLAN. An attacker could exploit this vulnerability by sending a malicious LLDP packet on the adjacent subnet to the Cisco Nexus 9000 Series Switch in ACI mode. A successful exploit could allow the attacker to connect an unauthorized server to the infrastructure VLAN, which is highly privileged. With a connection to the infrastructure VLAN, the attacker can make unauthorized connections to Cisco Application Policy Infrastructure Controller (APIC) services or join other host endpoints.
Aliases
Aliases
{ "GSD": { "alias": "CVE-2019-1890", "description": "A vulnerability in the fabric infrastructure VLAN connection establishment of the Cisco Nexus 9000 Series Application Centric Infrastructure (ACI) Mode Switch Software could allow an unauthenticated, adjacent attacker to bypass security validations and connect an unauthorized server to the infrastructure VLAN. The vulnerability is due to insufficient security requirements during the Link Layer Discovery Protocol (LLDP) setup phase of the infrastructure VLAN. An attacker could exploit this vulnerability by sending a malicious LLDP packet on the adjacent subnet to the Cisco Nexus 9000 Series Switch in ACI mode. A successful exploit could allow the attacker to connect an unauthorized server to the infrastructure VLAN, which is highly privileged. With a connection to the infrastructure VLAN, the attacker can make unauthorized connections to Cisco Application Policy Infrastructure Controller (APIC) services or join other host endpoints.", "id": "GSD-2019-1890" }, "gsd": { "metadata": { "exploitCode": "unknown", "remediation": "unknown", "reportConfidence": "confirmed", "type": "vulnerability" }, "osvSchema": { "aliases": [ "CVE-2019-1890" ], "details": "A vulnerability in the fabric infrastructure VLAN connection establishment of the Cisco Nexus 9000 Series Application Centric Infrastructure (ACI) Mode Switch Software could allow an unauthenticated, adjacent attacker to bypass security validations and connect an unauthorized server to the infrastructure VLAN. The vulnerability is due to insufficient security requirements during the Link Layer Discovery Protocol (LLDP) setup phase of the infrastructure VLAN. An attacker could exploit this vulnerability by sending a malicious LLDP packet on the adjacent subnet to the Cisco Nexus 9000 Series Switch in ACI mode. A successful exploit could allow the attacker to connect an unauthorized server to the infrastructure VLAN, which is highly privileged. With a connection to the infrastructure VLAN, the attacker can make unauthorized connections to Cisco Application Policy Infrastructure Controller (APIC) services or join other host endpoints.", "id": "GSD-2019-1890", "modified": "2023-12-13T01:23:51.624184Z", "schema_version": "1.4.0" } }, "namespaces": { "cve.org": { "CVE_data_meta": { "ASSIGNER": "psirt@cisco.com", "DATE_PUBLIC": "2019-07-03T16:00:00-0700", "ID": "CVE-2019-1890", "STATE": "PUBLIC", "TITLE": "Cisco Nexus 9000 Series Fabric Switches ACI Mode Fabric Infrastructure VLAN Unauthorized Access Vulnerability" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "Cisco NX-OS System Software in ACI Mode 11.0.1b", "version": { "version_data": [ { "affected": "\u003c", "version_value": "14.1(2g)" } ] } } ] }, "vendor_name": "Cisco" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability in the fabric infrastructure VLAN connection establishment of the Cisco Nexus 9000 Series Application Centric Infrastructure (ACI) Mode Switch Software could allow an unauthenticated, adjacent attacker to bypass security validations and connect an unauthorized server to the infrastructure VLAN. The vulnerability is due to insufficient security requirements during the Link Layer Discovery Protocol (LLDP) setup phase of the infrastructure VLAN. An attacker could exploit this vulnerability by sending a malicious LLDP packet on the adjacent subnet to the Cisco Nexus 9000 Series Switch in ACI mode. A successful exploit could allow the attacker to connect an unauthorized server to the infrastructure VLAN, which is highly privileged. With a connection to the infrastructure VLAN, the attacker can make unauthorized connections to Cisco Application Policy Infrastructure Controller (APIC) services or join other host endpoints." } ] }, "exploit": [ { "lang": "eng", "value": "The Cisco Product Security Incident Response Team (PSIRT) is not aware of any public announcements or malicious use of the vulnerability that is described in this advisory. " } ], "impact": { "cvss": { "baseScore": "7.4", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:C/C:N/I:H/A:N ", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-284" } ] } ] }, "references": { "reference_data": [ { "name": "20190703 Cisco Nexus 9000 Series Fabric Switches ACI Mode Fabric Infrastructure VLAN Unauthorized Access Vulnerability", "refsource": "CISCO", "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20190703-n9kaci-bypass" }, { "name": "109052", "refsource": "BID", "url": "http://www.securityfocus.com/bid/109052" } ] }, "source": { "advisory": "cisco-sa-20190703-n9kaci-bypass", "defect": [ [ "CSCvp64280" ] ], "discovery": "INTERNAL" } }, "nvd.nist.gov": { "configurations": { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:a:cisco:application_policy_infrastructure_controller:7.3\\(0\\)zn\\(0.113\\):*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:cisco:n9k-x9432c-s:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false }, { "cpe23Uri": "cpe:2.3:h:cisco:n9k-x9464tx2:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false }, { "cpe23Uri": "cpe:2.3:h:cisco:n9k-x9732c-fx:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false }, { "cpe23Uri": "cpe:2.3:h:cisco:n9k-x9736c-fx:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false }, { "cpe23Uri": "cpe:2.3:h:cisco:nexus_93120tx:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false }, { "cpe23Uri": "cpe:2.3:h:cisco:nexus_93180yc-ex:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false }, { "cpe23Uri": "cpe:2.3:h:cisco:nexus_9348gc-fxp:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false }, { "cpe23Uri": "cpe:2.3:h:cisco:nexus_9364c:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false }, { "cpe23Uri": "cpe:2.3:h:cisco:n9k-x9564px:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false }, { "cpe23Uri": "cpe:2.3:h:cisco:n9k-x9564tx:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false }, { "cpe23Uri": "cpe:2.3:h:cisco:n9k-x9636c-r:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false }, { "cpe23Uri": "cpe:2.3:h:cisco:n9k-x9636c-rx:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false }, { "cpe23Uri": "cpe:2.3:h:cisco:n9k-x97160yc-ex:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false }, { "cpe23Uri": "cpe:2.3:h:cisco:nexus_93216tc-fx2:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false }, { "cpe23Uri": "cpe:2.3:h:cisco:nexus_93240yc-fx2:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false }, { "cpe23Uri": "cpe:2.3:h:cisco:nexus_9332c:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false }, { "cpe23Uri": "cpe:2.3:h:cisco:nexus_93360yc-fx2:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false }, { "cpe23Uri": "cpe:2.3:h:cisco:9432pq:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false }, { "cpe23Uri": "cpe:2.3:h:cisco:9536pq:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false }, { "cpe23Uri": "cpe:2.3:h:cisco:9636pq:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false }, { "cpe23Uri": "cpe:2.3:h:cisco:n9k-x9788tc-fx:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false }, { "cpe23Uri": "cpe:2.3:h:cisco:nexus_92160yc-x:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false }, { "cpe23Uri": "cpe:2.3:h:cisco:nexus_93108tc-ex:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false }, { "cpe23Uri": "cpe:2.3:h:cisco:nexus_93108tc-fx:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false }, { "cpe23Uri": "cpe:2.3:h:cisco:x9636q-r:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false }, { "cpe23Uri": "cpe:2.3:h:cisco:9736pq:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false }, { "cpe23Uri": "cpe:2.3:h:cisco:n9k-x9464px:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false }, { "cpe23Uri": "cpe:2.3:h:cisco:n9k-x9732c-ex:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false }, { "cpe23Uri": "cpe:2.3:h:cisco:n9k-x9736c-ex:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false }, { "cpe23Uri": "cpe:2.3:h:cisco:nexus_9316d-gx:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false }, { "cpe23Uri": "cpe:2.3:h:cisco:nexus_93180yc-fx:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false }, { "cpe23Uri": "cpe:2.3:h:cisco:nexus_9336c-fx2:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false }, { "cpe23Uri": "cpe:2.3:h:cisco:nexus_93600cd-gx:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] }, "cve": { "CVE_data_meta": { "ASSIGNER": "psirt@cisco.com", "ID": "CVE-2019-1890" }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "en", "value": "A vulnerability in the fabric infrastructure VLAN connection establishment of the Cisco Nexus 9000 Series Application Centric Infrastructure (ACI) Mode Switch Software could allow an unauthenticated, adjacent attacker to bypass security validations and connect an unauthorized server to the infrastructure VLAN. The vulnerability is due to insufficient security requirements during the Link Layer Discovery Protocol (LLDP) setup phase of the infrastructure VLAN. An attacker could exploit this vulnerability by sending a malicious LLDP packet on the adjacent subnet to the Cisco Nexus 9000 Series Switch in ACI mode. A successful exploit could allow the attacker to connect an unauthorized server to the infrastructure VLAN, which is highly privileged. With a connection to the infrastructure VLAN, the attacker can make unauthorized connections to Cisco Application Policy Infrastructure Controller (APIC) services or join other host endpoints." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "en", "value": "NVD-CWE-Other" } ] } ] }, "references": { "reference_data": [ { "name": "20190703 Cisco Nexus 9000 Series Fabric Switches ACI Mode Fabric Infrastructure VLAN Unauthorized Access Vulnerability", "refsource": "CISCO", "tags": [ "Vendor Advisory" ], "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20190703-n9kaci-bypass" }, { "name": "109052", "refsource": "BID", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "http://www.securityfocus.com/bid/109052" } ] } }, "impact": { "baseMetricV2": { "acInsufInfo": false, "cvssV2": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "availabilityImpact": "NONE", "baseScore": 3.3, "confidentialityImpact": "NONE", "integrityImpact": "PARTIAL", "vectorString": "AV:A/AC:L/Au:N/C:N/I:P/A:N", "version": "2.0" }, "exploitabilityScore": 6.5, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "LOW", "userInteractionRequired": false }, "baseMetricV3": { "cvssV3": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "NONE", "baseScore": 6.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 3.6 } }, "lastModifiedDate": "2020-10-16T15:09Z", "publishedDate": "2019-07-04T20:15Z" } } }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.