GSD-2020-12527
Vulnerability from gsd - Updated: 2023-12-13 01:21Details
An issue was discovered in MB connect line mymbCONNECT24, mbCONNECT24 and Helmholz myREX24 and myREX24.virtual in all versions through v2.11.2. Improper access validation allows a logged in user to shutdown or reboot devices in his account without having corresponding permissions.
Aliases
Aliases
{
"GSD": {
"alias": "CVE-2020-12527",
"description": "An issue was discovered in MB connect line mymbCONNECT24 and mbCONNECT24 software in all versions through V2.6.2. Improper use of access validation allows a logged in user to interact with devices in the account he should not have access to.",
"id": "GSD-2020-12527"
},
"gsd": {
"metadata": {
"exploitCode": "unknown",
"remediation": "unknown",
"reportConfidence": "confirmed",
"type": "vulnerability"
},
"osvSchema": {
"aliases": [
"CVE-2020-12527"
],
"details": "An issue was discovered in MB connect line mymbCONNECT24, mbCONNECT24 and Helmholz myREX24 and myREX24.virtual in all versions through v2.11.2. Improper access validation allows a logged in user to shutdown or reboot devices in his account without having corresponding permissions.",
"id": "GSD-2020-12527",
"modified": "2023-12-13T01:21:49.611473Z",
"schema_version": "1.4.0"
}
},
"namespaces": {
"cve.org": {
"CVE_data_meta": {
"ASSIGNER": "info@cert.vde.com",
"DATE_PUBLIC": "2022-09-07T12:50:00.000Z",
"ID": "CVE-2020-12527",
"STATE": "PUBLIC",
"TITLE": "Improper Access Validation in products of MB connect line and Helmholz"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "mymbCONNECT24",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_name": "2.6.2",
"version_value": "2.11.2"
}
]
}
},
{
"product_name": "mbCONNECT24",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_name": "2.6.2",
"version_value": "2.11.2"
}
]
}
}
]
},
"vendor_name": "MB connect line"
},
{
"product": {
"product_data": [
{
"product_name": "myREX24",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_name": "2",
"version_value": "2.11.2"
}
]
}
},
{
"product_name": "myREX24.virtual",
"version": {
"version_data": [
{
"version_name": "2",
"version_value": "2.11.2"
}
]
}
}
]
},
"vendor_name": "Helmholz"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "OTORIO reported the vulnerabilities to MB connect line. CERT@VDE coordinated."
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "An issue was discovered in MB connect line mymbCONNECT24, mbCONNECT24 and Helmholz myREX24 and myREX24.virtual in all versions through v2.11.2. Improper access validation allows a logged in user to shutdown or reboot devices in his account without having corresponding permissions."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-269 Improper Privilege Management"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://cert.vde.com/en/advisories/VDE-2021-003",
"refsource": "CONFIRM",
"url": "https://cert.vde.com/en/advisories/VDE-2021-003"
},
{
"name": "https://cert.vde.com/en/advisories/VDE-2022-039",
"refsource": "CONFIRM",
"url": "https://cert.vde.com/en/advisories/VDE-2022-039"
}
]
},
"solution": [
{
"lang": "eng",
"value": "Update to v2.12.1"
}
],
"source": {
"advisory": "VDE-2021-003",
"discovery": "EXTERNAL"
}
},
"nvd.nist.gov": {
"configurations": {
"CVE_data_version": "4.0",
"nodes": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:a:mbconnectline:mbconnect24:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "2.11.2",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:mbconnectline:mymbconnect24:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "2.11.2",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:a:helmholz:myrex24.virtual:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "2.11.2",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:helmholz:myrex24:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "2.11.2",
"vulnerable": true
}
],
"operator": "OR"
}
]
},
"cve": {
"CVE_data_meta": {
"ASSIGNER": "info@cert.vde.com",
"ID": "CVE-2020-12527"
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "en",
"value": "An issue was discovered in MB connect line mymbCONNECT24, mbCONNECT24 and Helmholz myREX24 and myREX24.virtual in all versions through v2.11.2. Improper access validation allows a logged in user to shutdown or reboot devices in his account without having corresponding permissions."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "en",
"value": "CWE-269"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://cert.vde.com/en/advisories/VDE-2022-039",
"refsource": "CONFIRM",
"tags": [
"Third Party Advisory"
],
"url": "https://cert.vde.com/en/advisories/VDE-2022-039"
},
{
"name": "https://cert.vde.com/en/advisories/VDE-2021-003",
"refsource": "CONFIRM",
"tags": [
"Third Party Advisory"
],
"url": "https://cert.vde.com/en/advisories/VDE-2021-003"
}
]
}
},
"impact": {
"baseMetricV2": {
"acInsufInfo": false,
"cvssV2": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"availabilityImpact": "COMPLETE",
"baseScore": 6.8,
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"vectorString": "AV:N/AC:L/Au:S/C:N/I:N/A:C",
"version": "2.0"
},
"exploitabilityScore": 8.0,
"impactScore": 6.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "MEDIUM",
"userInteractionRequired": false
},
"baseMetricV3": {
"cvssV3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 3.6
}
},
"lastModifiedDate": "2023-02-10T18:03Z",
"publishedDate": "2021-03-02T22:15Z"
}
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…