gsd-2020-7484
Vulnerability from gsd
Modified
2023-12-13 01:21
Details
**VERSION NOT SUPPORTED WHEN ASSIGNED** A vulnerability with the former 'password' feature could allow a denial of service attack if the user is not following documented guidelines pertaining to dedicated TriStation connection and key-switch protection. This vulnerability was discovered and remediated in versions v4.9.1 and v4.10.1 on May 30, 2013. This feature is not present in version v4.9.1 and v4.10.1 through current. Therefore, the vulnerability is not present in these versions.
Aliases
Aliases
{ "GSD": { "alias": "CVE-2020-7484", "description": "**VERSION NOT SUPPORTED WHEN ASSIGNED** A vulnerability with the former \u0027password\u0027 feature could allow a denial of service attack if the user is not following documented guidelines pertaining to dedicated TriStation connection and key-switch protection. This vulnerability was discovered and remediated in versions v4.9.1 and v4.10.1 on May 30, 2013. This feature is not present in version v4.9.1 and v4.10.1 through current. Therefore, the vulnerability is not present in these versions.", "id": "GSD-2020-7484" }, "gsd": { "metadata": { "exploitCode": "unknown", "remediation": "unknown", "reportConfidence": "confirmed", "type": "vulnerability" }, "osvSchema": { "aliases": [ "CVE-2020-7484" ], "details": "**VERSION NOT SUPPORTED WHEN ASSIGNED** A vulnerability with the former \u0027password\u0027 feature could allow a denial of service attack if the user is not following documented guidelines pertaining to dedicated TriStation connection and key-switch protection. This vulnerability was discovered and remediated in versions v4.9.1 and v4.10.1 on May 30, 2013. This feature is not present in version v4.9.1 and v4.10.1 through current. Therefore, the vulnerability is not present in these versions.", "id": "GSD-2020-7484", "modified": "2023-12-13T01:21:52.269937Z", "schema_version": "1.4.0" } }, "namespaces": { "cve.org": { "CVE_data_meta": { "ASSIGNER": "cybersecurity@schneider-electric.com", "ID": "CVE-2020-7484", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "TriStation TS1131 (v4.0.0 to v4.9.0, v4.10.0)", "version": { "version_data": [ { "version_value": "TriStation TS1131 (v4.0.0 to v4.9.0, v4.10.0)" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "**VERSION NOT SUPPORTED WHEN ASSIGNED** A vulnerability with the former \u0027password\u0027 feature could allow a denial of service attack if the user is not following documented guidelines pertaining to dedicated TriStation connection and key-switch protection. This vulnerability was discovered and remediated in versions v4.9.1 and v4.10.1 on May 30, 2013. This feature is not present in version v4.9.1 and v4.10.1 through current. Therefore, the vulnerability is not present in these versions." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "denial of service" } ] } ] }, "references": { "reference_data": [ { "name": "https://www.se.com/ww/en/download/document/SESB-2020-105-01", "refsource": "MISC", "url": "https://www.se.com/ww/en/download/document/SESB-2020-105-01" }, { "name": "https://us-cert.cisa.gov/ics/advisories/icsa-20-205-01", "refsource": "MISC", "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-205-01" } ] } }, "nvd.nist.gov": { "configurations": { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:a:schneider-electric:tristation_1131:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "4.13.0", "versionStartIncluding": "1.0", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:microsoft:windows_7:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false }, { "cpe23Uri": "cpe:2.3:o:microsoft:windows_nt:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false }, { "cpe23Uri": "cpe:2.3:o:microsoft:windows_xp:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] }, "cve": { "CVE_data_meta": { "ASSIGNER": "cybersecurity@schneider-electric.com", "ID": "CVE-2020-7484" }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "en", "value": "**VERSION NOT SUPPORTED WHEN ASSIGNED** A vulnerability with the former \u0027password\u0027 feature could allow a denial of service attack if the user is not following documented guidelines pertaining to dedicated TriStation connection and key-switch protection. This vulnerability was discovered and remediated in versions v4.9.1 and v4.10.1 on May 30, 2013. This feature is not present in version v4.9.1 and v4.10.1 through current. Therefore, the vulnerability is not present in these versions." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "en", "value": "NVD-CWE-noinfo" } ] } ] }, "references": { "reference_data": [ { "name": "https://www.se.com/ww/en/download/document/SESB-2020-105-01", "refsource": "MISC", "tags": [ "Vendor Advisory" ], "url": "https://www.se.com/ww/en/download/document/SESB-2020-105-01" }, { "name": "https://us-cert.cisa.gov/ics/advisories/icsa-20-205-01", "refsource": "MISC", "tags": [ "Third Party Advisory", "US Government Resource" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-205-01" } ] } }, "impact": { "baseMetricV2": { "acInsufInfo": false, "cvssV2": { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 4.3, "confidentialityImpact": "NONE", "integrityImpact": "NONE", "vectorString": "AV:N/AC:M/Au:N/C:N/I:N/A:P", "version": "2.0" }, "exploitabilityScore": 8.6, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "MEDIUM", "userInteractionRequired": false }, "baseMetricV3": { "cvssV3": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 3.6 } }, "lastModifiedDate": "2021-11-10T17:11Z", "publishedDate": "2020-04-16T19:15Z" } } }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.