GSD-2022-38743
Vulnerability from gsd - Updated: 2023-12-13 01:19Details
Rockwell Automation FactoryTalk VantagePoint versions 8.0, 8.10, 8.20, 8.30, 8.31 are vulnerable to an improper access control vulnerability. The FactoryTalk VantagePoint SQL Server account could allow a malicious user with read-only privileges to execute SQL statements in the back-end database. If successfully exploited, this could allow the attacker to execute arbitrary code and gain access to restricted data.
Aliases
Aliases
{
"GSD": {
"alias": "CVE-2022-38743",
"description": "Rockwell Automation FactoryTalk VantagePoint versions 8.0, 8.10, 8.20, 8.30, 8.31 are vulnerable to an improper access control vulnerability. The FactoryTalk VantagePoint SQL Server account could allow a malicious user with read-only privileges to execute SQL statements in the back-end database. If successfully exploited, this could allow the attacker to execute arbitrary code and gain access to restricted data.",
"id": "GSD-2022-38743"
},
"gsd": {
"metadata": {
"exploitCode": "unknown",
"remediation": "unknown",
"reportConfidence": "confirmed",
"type": "vulnerability"
},
"osvSchema": {
"aliases": [
"CVE-2022-38743"
],
"details": "Rockwell Automation FactoryTalk VantagePoint versions 8.0, 8.10, 8.20, 8.30, 8.31 are vulnerable to an improper access control vulnerability. The FactoryTalk VantagePoint SQL Server account could allow a malicious user with read-only privileges to execute SQL statements in the back-end database. If successfully exploited, this could allow the attacker to execute arbitrary code and gain access to restricted data.",
"id": "GSD-2022-38743",
"modified": "2023-12-13T01:19:22.471207Z",
"schema_version": "1.4.0"
}
},
"namespaces": {
"cve.org": {
"CVE_data_meta": {
"ASSIGNER": "PSIRT@rockwellautomation.com",
"ID": "CVE-2022-38743",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "FactoryTalk VantagePoint",
"version": {
"version_data": [
{
"version_value": "8.0, 8.10, 8.20, 8.30, 8.31"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Rockwell Automation FactoryTalk VantagePoint versions 8.0, 8.10, 8.20, 8.30, 8.31 are vulnerable to an improper access control vulnerability. The FactoryTalk VantagePoint SQL Server account could allow a malicious user with read-only privileges to execute SQL statements in the back-end database. If successfully exploited, this could allow the attacker to execute arbitrary code and gain access to restricted data."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-284 Improper Access Control"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1137043",
"refsource": "MISC",
"url": "https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1137043"
}
]
}
},
"nvd.nist.gov": {
"configurations": {
"CVE_data_version": "4.0",
"nodes": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:a:rockwellautomation:factorytalk_vantagepoint:8.0:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:rockwellautomation:factorytalk_vantagepoint:8.10:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:rockwellautomation:factorytalk_vantagepoint:8.20:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:rockwellautomation:factorytalk_vantagepoint:8.30:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:rockwellautomation:factorytalk_vantagepoint:8.31:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
}
]
},
"cve": {
"CVE_data_meta": {
"ASSIGNER": "PSIRT@rockwellautomation.com",
"ID": "CVE-2022-38743"
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "en",
"value": "Rockwell Automation FactoryTalk VantagePoint versions 8.0, 8.10, 8.20, 8.30, 8.31 are vulnerable to an improper access control vulnerability. The FactoryTalk VantagePoint SQL Server account could allow a malicious user with read-only privileges to execute SQL statements in the back-end database. If successfully exploited, this could allow the attacker to execute arbitrary code and gain access to restricted data."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "en",
"value": "NVD-CWE-Other"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1137043",
"refsource": "MISC",
"tags": [
"Permissions Required",
"Vendor Advisory"
],
"url": "https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1137043"
}
]
}
},
"impact": {
"baseMetricV3": {
"cvssV3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 5.9
}
},
"lastModifiedDate": "2022-10-19T17:55Z",
"publishedDate": "2022-10-17T21:15Z"
}
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…