gsd-2022-4046
Vulnerability from gsd
Modified
2023-12-13 01:19
Details
In CODESYS Control in multiple versions a improper restriction of operations within the bounds of a memory buffer allow an remote attacker with user privileges to gain full access of the device.
Aliases
Aliases
{ "GSD": { "alias": "CVE-2022-4046", "id": "GSD-2022-4046" }, "gsd": { "metadata": { "exploitCode": "unknown", "remediation": "unknown", "reportConfidence": "confirmed", "type": "vulnerability" }, "osvSchema": { "aliases": [ "CVE-2022-4046" ], "details": "In CODESYS Control in multiple versions a improper restriction of operations within the bounds of a memory buffer allow an remote attacker with user privileges to gain full access of the device.", "id": "GSD-2022-4046", "modified": "2023-12-13T01:19:15.968962Z", "schema_version": "1.4.0" } }, "namespaces": { "cve.org": { "CVE_data_meta": { "ASSIGNER": "info@cert.vde.com", "ID": "CVE-2022-4046", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "CODESYS Control for BeagleBone SL", "version": { "version_data": [ { "version_value": "not down converted", "x_cve_json_5_version_data": { "defaultStatus": "affected", "versions": [ { "status": "affected", "version": "all" } ] } } ] } }, { "product_name": "CODESYS Control for emPC-A/iMX6 SL", "version": { "version_data": [ { "version_value": "not down converted", "x_cve_json_5_version_data": { "defaultStatus": "affected", "versions": [ { "status": "affected", "version": "all" } ] } } ] } }, { "product_name": "CODESYS Control for IOT2000 SL", "version": { "version_data": [ { "version_value": "not down converted", "x_cve_json_5_version_data": { "defaultStatus": "affected", "versions": [ { "status": "affected", "version": "all" } ] } } ] } }, { "product_name": "CODESYS Control for Linux SL", "version": { "version_data": [ { "version_value": "not down converted", "x_cve_json_5_version_data": { "defaultStatus": "affected", "versions": [ { "status": "affected", "version": "all" } ] } } ] } }, { "product_name": "CODESYS Control for PFC100 SL", "version": { "version_data": [ { "version_value": "not down converted", "x_cve_json_5_version_data": { "defaultStatus": "affected", "versions": [ { "status": "affected", "version": "all" } ] } } ] } }, { "product_name": "CODESYS Control for PFC200 SL", "version": { "version_data": [ { "version_value": "not down converted", "x_cve_json_5_version_data": { "defaultStatus": "affected", "versions": [ { "status": "affected", "version": "all" } ] } } ] } }, { "product_name": "CODESYS Control for PLCnext SL", "version": { "version_data": [ { "version_value": "not down converted", "x_cve_json_5_version_data": { "defaultStatus": "affected", "versions": [ { "status": "affected", "version": "all" } ] } } ] } }, { "product_name": "CODESYS Control for Raspberry Pi SL", "version": { "version_data": [ { "version_value": "not down converted", "x_cve_json_5_version_data": { "defaultStatus": "affected", "versions": [ { "status": "affected", "version": "all" } ] } } ] } }, { "product_name": "CODESYS Control for WAGO Touch Panels 600 SL", "version": { "version_data": [ { "version_value": "not down converted", "x_cve_json_5_version_data": { "defaultStatus": "affected", "versions": [ { "status": "affected", "version": "all" } ] } } ] } }, { "product_name": "CODESYS Control RTE (for Beckhoff CX) SL", "version": { "version_data": [ { "version_value": "not down converted", "x_cve_json_5_version_data": { "defaultStatus": "affected", "versions": [ { "status": "affected", "version": "all" } ] } } ] } }, { "product_name": "CODESYS Control RTE (SL)", "version": { "version_data": [ { "version_value": "not down converted", "x_cve_json_5_version_data": { "defaultStatus": "affected", "versions": [ { "status": "affected", "version": "all" } ] } } ] } }, { "product_name": "CODESYS Control Runtime System Toolkit", "version": { "version_data": [ { "version_value": "not down converted", "x_cve_json_5_version_data": { "defaultStatus": "affected", "versions": [ { "status": "affected", "version": "all" } ] } } ] } }, { "product_name": "CODESYS Control Win (SL)", "version": { "version_data": [ { "version_value": "not down converted", "x_cve_json_5_version_data": { "defaultStatus": "affected", "versions": [ { "status": "affected", "version": "all" } ] } } ] } }, { "product_name": "CODESYS HMI (SL)", "version": { "version_data": [ { "version_value": "not down converted", "x_cve_json_5_version_data": { "defaultStatus": "affected", "versions": [ { "status": "affected", "version": "all" } ] } } ] } } ] }, "vendor_name": "CODESYS" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "In CODESYS Control in multiple versions a improper restriction of operations within the bounds of a memory buffer allow an remote attacker with user privileges to gain full access of the device." } ] }, "generator": { "engine": "Vulnogram 0.1.0-dev" }, "impact": { "cvss": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "cweId": "CWE-119", "lang": "eng", "value": "CWE-119 Improper Restriction of Operations within the Bounds of a Memory Buffer" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert.vde.com/en/advisories/VDE-2023-025/", "refsource": "MISC", "url": "https://cert.vde.com/en/advisories/VDE-2023-025/" } ] }, "source": { "defect": [ "CERT@VDE#64299" ], "discovery": "EXTERNAL" } }, "nvd.nist.gov": { "configurations": { "CVE_data_version": "4.0", "nodes": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:a:codesys:control_for_beaglebone_sl:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:codesys:control_for_empc-a\\/imx6_sl:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:codesys:control_for_iot2000_sl:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:codesys:control_for_linux_sl:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:codesys:control_for_pfc100_sl:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:codesys:control_for_pfc200_sl:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:codesys:control_for_plcnext_sl:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:codesys:control_for_raspberry_pi_sl:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:codesys:control_for_wago_touch_panels_600_sl:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:codesys:control_rte_sl:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:codesys:control_rte_sl_\\(for_beckhoff_cx\\):*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:codesys:control_runtime_system_toolkit:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:codesys:control_win_sl:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:codesys:hmi_sl:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" } ] }, "cve": { "CVE_data_meta": { "ASSIGNER": "info@cert.vde.com", "ID": "CVE-2022-4046" }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "en", "value": "In CODESYS Control in multiple versions a improper restriction of operations within the bounds of a memory buffer allow an remote attacker with user privileges to gain full access of the device." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "en", "value": "CWE-119" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert.vde.com/en/advisories/VDE-2023-025/", "refsource": "MISC", "tags": [ "Mitigation", "Third Party Advisory" ], "url": "https://cert.vde.com/en/advisories/VDE-2023-025/" } ] } }, "impact": { "baseMetricV3": { "cvssV3": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9 } }, "lastModifiedDate": "2023-08-08T15:54Z", "publishedDate": "2023-08-03T13:15Z" } } }
Loading...
Loading...
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.