gsd-2023-20048
Vulnerability from gsd
Modified
2023-12-13 01:20
Details
A vulnerability in the web services interface of Cisco Firepower Management Center (FMC) Software could allow an authenticated, remote attacker to execute certain unauthorized configuration commands on a Firepower Threat Defense (FTD) device that is managed by the FMC Software. This vulnerability is due to insufficient authorization of configuration commands that are sent through the web service interface. An attacker could exploit this vulnerability by authenticating to the FMC web services interface and sending a crafted HTTP request to an affected device. A successful exploit could allow the attacker to execute certain configuration commands on the targeted FTD device. To successfully exploit this vulnerability, an attacker would need valid credentials on the FMC Software.
Aliases
Aliases
{ "GSD": { "alias": "CVE-2023-20048", "id": "GSD-2023-20048" }, "gsd": { "metadata": { "exploitCode": "unknown", "remediation": "unknown", "reportConfidence": "confirmed", "type": "vulnerability" }, "osvSchema": { "aliases": [ "CVE-2023-20048" ], "details": "A vulnerability in the web services interface of Cisco Firepower Management Center (FMC) Software could allow an authenticated, remote attacker to execute certain unauthorized configuration commands on a Firepower Threat Defense (FTD) device that is managed by the FMC Software. This vulnerability is due to insufficient authorization of configuration commands that are sent through the web service interface. An attacker could exploit this vulnerability by authenticating to the FMC web services interface and sending a crafted HTTP request to an affected device. A successful exploit could allow the attacker to execute certain configuration commands on the targeted FTD device. To successfully exploit this vulnerability, an attacker would need valid credentials on the FMC Software.", "id": "GSD-2023-20048", "modified": "2023-12-13T01:20:29.322504Z", "schema_version": "1.4.0" } }, "namespaces": { "cve.org": { "CVE_data_meta": { "ASSIGNER": "psirt@cisco.com", "ID": "CVE-2023-20048", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "Cisco Firepower Management Center", "version": { "version_data": [ { "version_affected": "=", "version_value": "6.2.3" }, { "version_affected": "=", "version_value": "6.2.3.1" }, { "version_affected": "=", "version_value": "6.2.3.2" }, { "version_affected": "=", "version_value": "6.2.3.3" }, { "version_affected": "=", "version_value": "6.2.3.4" }, { "version_affected": "=", "version_value": "6.2.3.5" }, { "version_affected": "=", "version_value": "6.2.3.6" }, { "version_affected": "=", "version_value": "6.2.3.7" }, { "version_affected": "=", "version_value": "6.2.3.9" }, { "version_affected": "=", "version_value": "6.2.3.10" }, { "version_affected": "=", "version_value": "6.2.3.11" }, { "version_affected": "=", "version_value": "6.2.3.12" }, { "version_affected": "=", "version_value": "6.2.3.13" }, { "version_affected": "=", "version_value": "6.2.3.14" }, { "version_affected": "=", "version_value": "6.2.3.15" }, { "version_affected": "=", "version_value": "6.2.3.8" }, { "version_affected": "=", "version_value": "6.2.3.16" }, { "version_affected": "=", "version_value": "6.2.3.17" }, { "version_affected": "=", "version_value": "6.2.3.18" }, { "version_affected": "=", "version_value": "6.4.0" }, { "version_affected": "=", "version_value": "6.4.0.1" }, { "version_affected": "=", "version_value": "6.4.0.3" }, { "version_affected": "=", "version_value": "6.4.0.2" }, { "version_affected": "=", "version_value": "6.4.0.4" }, { "version_affected": "=", "version_value": "6.4.0.5" }, { "version_affected": "=", "version_value": "6.4.0.6" }, { "version_affected": "=", "version_value": "6.4.0.7" }, { "version_affected": "=", "version_value": "6.4.0.8" }, { "version_affected": "=", "version_value": "6.4.0.9" }, { "version_affected": "=", "version_value": "6.4.0.10" }, { "version_affected": "=", "version_value": "6.4.0.11" }, { "version_affected": "=", "version_value": "6.4.0.12" }, { "version_affected": "=", "version_value": "6.4.0.13" }, { "version_affected": "=", "version_value": "6.4.0.14" }, { "version_affected": "=", "version_value": "6.4.0.15" }, { "version_affected": "=", "version_value": "6.4.0.16" }, { "version_affected": "=", "version_value": "6.6.0" }, { "version_affected": "=", "version_value": "6.6.0.1" }, { "version_affected": "=", "version_value": "6.6.1" }, { "version_affected": "=", "version_value": "6.6.3" }, { "version_affected": "=", "version_value": "6.6.4" }, { "version_affected": "=", "version_value": "6.6.5" }, { "version_affected": "=", "version_value": "6.6.5.1" }, { "version_affected": "=", "version_value": "6.6.5.2" }, { "version_affected": "=", "version_value": "6.6.7" }, { "version_affected": "=", "version_value": "6.6.7.1" }, { "version_affected": "=", "version_value": "6.7.0" }, { "version_affected": "=", "version_value": "6.7.0.1" }, { "version_affected": "=", "version_value": "6.7.0.2" }, { "version_affected": "=", "version_value": "6.7.0.3" }, { "version_affected": "=", "version_value": "7.0.0" }, { "version_affected": "=", "version_value": "7.0.0.1" }, { "version_affected": "=", "version_value": "7.0.1" }, { "version_affected": "=", "version_value": "7.0.1.1" }, { "version_affected": "=", "version_value": "7.0.2" }, { "version_affected": "=", "version_value": "7.0.2.1" }, { "version_affected": "=", "version_value": "7.0.3" }, { "version_affected": "=", "version_value": "7.0.4" }, { "version_affected": "=", "version_value": "7.0.5" }, { "version_affected": "=", "version_value": "7.1.0" }, { "version_affected": "=", "version_value": "7.1.0.1" }, { "version_affected": "=", "version_value": "7.1.0.2" }, { "version_affected": "=", "version_value": "7.1.0.3" }, { "version_affected": "=", "version_value": "7.2.0" }, { "version_affected": "=", "version_value": "7.2.1" }, { "version_affected": "=", "version_value": "7.2.2" }, { "version_affected": "=", "version_value": "7.2.0.1" }, { "version_affected": "=", "version_value": "7.2.3" }, { "version_affected": "=", "version_value": "7.2.3.1" }, { "version_affected": "=", "version_value": "7.3.0" }, { "version_affected": "=", "version_value": "7.3.1" }, { "version_affected": "=", "version_value": "7.3.1.1" } ] } } ] }, "vendor_name": "Cisco" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability in the web services interface of Cisco Firepower Management Center (FMC) Software could allow an authenticated, remote attacker to execute certain unauthorized configuration commands on a Firepower Threat Defense (FTD) device that is managed by the FMC Software. This vulnerability is due to insufficient authorization of configuration commands that are sent through the web service interface. An attacker could exploit this vulnerability by authenticating to the FMC web services interface and sending a crafted HTTP request to an affected device. A successful exploit could allow the attacker to execute certain configuration commands on the targeted FTD device. To successfully exploit this vulnerability, an attacker would need valid credentials on the FMC Software." } ] }, "exploit": [ { "lang": "en", "value": "The Cisco Product Security Incident Response Team (PSIRT) is not aware of any public announcements or malicious use of the vulnerability that is described in this advisory." } ], "impact": { "cvss": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.9, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "LOW", "privilegesRequired": "LOW", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:L/A:H", "version": "3.1" } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "cweId": "CWE-269", "lang": "eng", "value": "Improper Privilege Management" } ] } ] }, "references": { "reference_data": [ { "name": "https://sec.cloudapps.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-fmc-cmd-inj-29MP49hN", "refsource": "MISC", "url": "https://sec.cloudapps.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-fmc-cmd-inj-29MP49hN" } ] }, "source": { "advisory": "cisco-sa-fmc-cmd-inj-29MP49hN", "defects": [ "CSCwd02925" ], "discovery": "INTERNAL" } }, "nvd.nist.gov": { "cve": { "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:cisco:firepower_management_center:*:*:*:*:*:*:*:*", "matchCriteriaId": "B6BF3D02-3BA0-4736-B78D-3634E3E91623", "versionEndIncluding": "6.2.3.18", "versionStartIncluding": "6.2.3", "vulnerable": true }, { "criteria": "cpe:2.3:a:cisco:firepower_management_center:*:*:*:*:*:*:*:*", "matchCriteriaId": "6FBA1598-02FE-4855-8449-E2FF06EF8276", "versionEndIncluding": "6.4.0.16", "versionStartIncluding": "6.4.0", "vulnerable": true }, { "criteria": "cpe:2.3:a:cisco:firepower_management_center:*:*:*:*:*:*:*:*", "matchCriteriaId": "AF3259C7-8F36-46B1-A1BA-C2F9AC165A2D", "versionEndIncluding": "6.6.7.1", "versionStartIncluding": "6.6.0", "vulnerable": true }, { "criteria": "cpe:2.3:a:cisco:firepower_management_center:*:*:*:*:*:*:*:*", "matchCriteriaId": "79C97BD3-D82A-493B-BCBB-9909ED80D084", "versionEndIncluding": "6.7.0.3", "versionStartIncluding": "6.7.0", "vulnerable": true }, { "criteria": "cpe:2.3:a:cisco:firepower_management_center:*:*:*:*:*:*:*:*", "matchCriteriaId": "0BE29E8B-5D64-4CF6-B8CB-A38E991A9BB9", "versionEndIncluding": "7.0.5", "versionStartIncluding": "7.0.0", "vulnerable": true }, { "criteria": "cpe:2.3:a:cisco:firepower_management_center:*:*:*:*:*:*:*:*", "matchCriteriaId": "749D90E8-9009-4F05-8C5E-2521A9BC7D32", "versionEndIncluding": "7.1.0.3", "versionStartIncluding": "7.1.0", "vulnerable": true }, { "criteria": "cpe:2.3:a:cisco:firepower_management_center:*:*:*:*:*:*:*:*", "matchCriteriaId": "D44E33FB-20A2-448B-A901-3BD383E45F2B", "versionEndIncluding": "7.2.3.1", "versionStartIncluding": "7.2.0", "vulnerable": true }, { "criteria": "cpe:2.3:a:cisco:firepower_management_center:*:*:*:*:*:*:*:*", "matchCriteriaId": "E355BD8E-18E7-4405-8F32-0A191DCE0774", "versionEndIncluding": "7.3.1.1", "versionStartIncluding": "7.3.0", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability in the web services interface of Cisco Firepower Management Center (FMC) Software could allow an authenticated, remote attacker to execute certain unauthorized configuration commands on a Firepower Threat Defense (FTD) device that is managed by the FMC Software. This vulnerability is due to insufficient authorization of configuration commands that are sent through the web service interface. An attacker could exploit this vulnerability by authenticating to the FMC web services interface and sending a crafted HTTP request to an affected device. A successful exploit could allow the attacker to execute certain configuration commands on the targeted FTD device. To successfully exploit this vulnerability, an attacker would need valid credentials on the FMC Software." }, { "lang": "es", "value": "Una vulnerabilidad en la interfaz de servicios web del software Cisco Firepower Management Center (FMC) podr\u00eda permitir que un atacante remoto autenticado ejecute ciertos comandos de configuraci\u00f3n no autorizados en un dispositivo Firepower Threat Defense (FTD) administrado por el software FMC. Esta vulnerabilidad se debe a una autorizaci\u00f3n insuficiente de los comandos de configuraci\u00f3n que se env\u00edan a trav\u00e9s de la interfaz del servicio web. Un atacante podr\u00eda aprovechar esta vulnerabilidad autentic\u00e1ndose en la interfaz de servicios web de FMC y enviando una solicitud HTTP manipulada a un dispositivo afectado. Un exploit exitoso podr\u00eda permitir al atacante ejecutar ciertos comandos de configuraci\u00f3n en el dispositivo FTD objetivo. Para explotar con \u00e9xito esta vulnerabilidad, un atacante necesitar\u00eda credenciales v\u00e1lidas en el software FMC." } ], "id": "CVE-2023-20048", "lastModified": "2024-01-25T17:15:27.633", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.9, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.1, "impactScore": 6.0, "source": "nvd@nist.gov", "type": "Primary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.9, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "LOW", "privilegesRequired": "LOW", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:L/A:H", "version": "3.1" }, "exploitabilityScore": 3.1, "impactScore": 6.0, "source": "ykramarz@cisco.com", "type": "Secondary" } ] }, "published": "2023-11-01T18:15:08.907", "references": [ { "source": "ykramarz@cisco.com", "tags": [ "Vendor Advisory" ], "url": "https://sec.cloudapps.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-fmc-cmd-inj-29MP49hN" } ], "sourceIdentifier": "ykramarz@cisco.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-863" } ], "source": "nvd@nist.gov", "type": "Primary" }, { "description": [ { "lang": "en", "value": "CWE-269" } ], "source": "ykramarz@cisco.com", "type": "Secondary" } ] } } } }
Loading...
Loading...
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.