GCVE Workshop - 22 September 2026 (14:00-18:00), Luxembourg Before The Vulnopticon Conference - Registration

GSD-2023-2373

Vulnerability from gsd - Updated: 2023-12-13 01:20
Details
A vulnerability, which was classified as critical, was found in Ubiquiti EdgeRouter X up to 2.0.9-hotfix.6. This affects an unknown part of the component Web Management Interface. The manipulation of the argument ecn-up leads to command injection. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-227649 was assigned to this vulnerability.
Aliases
Aliases

{
  "GSD": {
    "alias": "CVE-2023-2373",
    "id": "GSD-2023-2373"
  },
  "gsd": {
    "metadata": {
      "exploitCode": "unknown",
      "remediation": "unknown",
      "reportConfidence": "confirmed",
      "type": "vulnerability"
    },
    "osvSchema": {
      "aliases": [
        "CVE-2023-2373"
      ],
      "details": "A vulnerability, which was classified as critical, was found in Ubiquiti EdgeRouter X up to 2.0.9-hotfix.6. This affects an unknown part of the component Web Management Interface. The manipulation of the argument ecn-up leads to command injection. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-227649 was assigned to this vulnerability.",
      "id": "GSD-2023-2373",
      "modified": "2023-12-13T01:20:32.252822Z",
      "schema_version": "1.4.0"
    }
  },
  "namespaces": {
    "cve.org": {
      "CVE_data_meta": {
        "ASSIGNER": "cna@vuldb.com",
        "ID": "CVE-2023-2373",
        "STATE": "PUBLIC"
      },
      "affects": {
        "vendor": {
          "vendor_data": [
            {
              "product": {
                "product_data": [
                  {
                    "product_name": "EdgeRouter X",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "=",
                          "version_value": "2.0.9-hotfix.0"
                        },
                        {
                          "version_affected": "=",
                          "version_value": "2.0.9-hotfix.1"
                        },
                        {
                          "version_affected": "=",
                          "version_value": "2.0.9-hotfix.2"
                        },
                        {
                          "version_affected": "=",
                          "version_value": "2.0.9-hotfix.3"
                        },
                        {
                          "version_affected": "=",
                          "version_value": "2.0.9-hotfix.4"
                        },
                        {
                          "version_affected": "=",
                          "version_value": "2.0.9-hotfix.5"
                        },
                        {
                          "version_affected": "=",
                          "version_value": "2.0.9-hotfix.6"
                        }
                      ]
                    }
                  }
                ]
              },
              "vendor_name": "Ubiquiti"
            }
          ]
        }
      },
      "credits": [
        {
          "lang": "en",
          "value": "leetmoon (VulDB User)"
        }
      ],
      "data_format": "MITRE",
      "data_type": "CVE",
      "data_version": "4.0",
      "description": {
        "description_data": [
          {
            "lang": "eng",
            "value": "A vulnerability, which was classified as critical, was found in Ubiquiti EdgeRouter X up to 2.0.9-hotfix.6. This affects an unknown part of the component Web Management Interface. The manipulation of the argument ecn-up leads to command injection. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-227649 was assigned to this vulnerability."
          },
          {
            "lang": "deu",
            "value": "Es wurde eine kritische Schwachstelle in Ubiquiti EdgeRouter X bis 2.0.9-hotfix.6 gefunden. Betroffen hiervon ist ein unbekannter Ablauf der Komponente Web Management Interface. Durch Manipulation des Arguments ecn-up mit unbekannten Daten kann eine command injection-Schwachstelle ausgenutzt werden. Umgesetzt werden kann der Angriff \u00fcber das Netzwerk. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
          }
        ]
      },
      "impact": {
        "cvss": [
          {
            "baseScore": 6.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
            "version": "3.1"
          },
          {
            "baseScore": 6.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
            "version": "3.0"
          },
          {
            "baseScore": 6.5,
            "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
            "version": "2.0"
          }
        ]
      },
      "problemtype": {
        "problemtype_data": [
          {
            "description": [
              {
                "cweId": "CWE-77",
                "lang": "eng",
                "value": "CWE-77 Command Injection"
              }
            ]
          }
        ]
      },
      "references": {
        "reference_data": [
          {
            "name": "https://vuldb.com/?id.227649",
            "refsource": "MISC",
            "url": "https://vuldb.com/?id.227649"
          },
          {
            "name": "https://vuldb.com/?ctiid.227649",
            "refsource": "MISC",
            "url": "https://vuldb.com/?ctiid.227649"
          },
          {
            "name": "https://github.com/leetsun/IoT/tree/main/EdgeRouterX/CI/5",
            "refsource": "MISC",
            "url": "https://github.com/leetsun/IoT/tree/main/EdgeRouterX/CI/5"
          }
        ]
      }
    },
    "nvd.nist.gov": {
      "cve": {
        "configurations": [
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:ui:edgemax_edgerouter_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "1D3FE42C-7A01-420B-BD79-60992B4DC90F",
                    "versionEndExcluding": "2.0.9",
                    "vulnerable": true
                  },
                  {
                    "criteria": "cpe:2.3:o:ui:edgemax_edgerouter_firmware:2.0.9:-:*:*:*:*:*:*",
                    "matchCriteriaId": "DD084B6E-95B1-43EC-B44D-067F84857006",
                    "vulnerable": true
                  },
                  {
                    "criteria": "cpe:2.3:o:ui:edgemax_edgerouter_firmware:2.0.9:hotfix1:*:*:*:*:*:*",
                    "matchCriteriaId": "C0CE2156-E44D-4137-B823-E29E9B504090",
                    "vulnerable": true
                  },
                  {
                    "criteria": "cpe:2.3:o:ui:edgemax_edgerouter_firmware:2.0.9:hotfix2:*:*:*:*:*:*",
                    "matchCriteriaId": "D674905D-1E0B-428D-826A-CB75E5E0313C",
                    "vulnerable": true
                  },
                  {
                    "criteria": "cpe:2.3:o:ui:edgemax_edgerouter_firmware:2.0.9:hotfix4:*:*:*:*:*:*",
                    "matchCriteriaId": "ACD593F1-F9C4-40F1-AE07-82015E69429F",
                    "vulnerable": true
                  },
                  {
                    "criteria": "cpe:2.3:o:ui:edgemax_edgerouter_firmware:2.0.9:hotfix5:*:*:*:*:*:*",
                    "matchCriteriaId": "643B67AA-ED41-4716-8449-E010B44F1900",
                    "vulnerable": true
                  },
                  {
                    "criteria": "cpe:2.3:o:ui:edgemax_edgerouter_firmware:2.0.9:hotfix6:*:*:*:*:*:*",
                    "matchCriteriaId": "ADEBD144-84BF-4A6C-B18F-4DBC6261D0D1",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:ui:er-x:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "91B9AD72-BF39-4731-85B9-26036F7C425B",
                    "vulnerable": false
                  },
                  {
                    "criteria": "cpe:2.3:h:ui:er-x-sfp:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "4F922D6E-7C6D-4984-A0DF-6EDC0C7A9900",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          }
        ],
        "descriptions": [
          {
            "lang": "en",
            "value": "A vulnerability, which was classified as critical, was found in Ubiquiti EdgeRouter X up to 2.0.9-hotfix.6. This affects an unknown part of the component Web Management Interface. The manipulation of the argument ecn-up leads to command injection. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-227649 was assigned to this vulnerability."
          }
        ],
        "id": "CVE-2023-2373",
        "lastModified": "2024-04-11T01:19:45.967",
        "metrics": {
          "cvssMetricV2": [
            {
              "acInsufInfo": false,
              "baseSeverity": "MEDIUM",
              "cvssData": {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "SINGLE",
                "availabilityImpact": "PARTIAL",
                "baseScore": 6.5,
                "confidentialityImpact": "PARTIAL",
                "integrityImpact": "PARTIAL",
                "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
                "version": "2.0"
              },
              "exploitabilityScore": 8.0,
              "impactScore": 6.4,
              "obtainAllPrivilege": false,
              "obtainOtherPrivilege": false,
              "obtainUserPrivilege": false,
              "source": "cna@vuldb.com",
              "type": "Secondary",
              "userInteractionRequired": false
            }
          ],
          "cvssMetricV31": [
            {
              "cvssData": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "exploitabilityScore": 2.8,
              "impactScore": 5.9,
              "source": "nvd@nist.gov",
              "type": "Primary"
            },
            {
              "cvssData": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "LOW",
                "baseScore": 6.3,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "LOW",
                "integrityImpact": "LOW",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
                "version": "3.1"
              },
              "exploitabilityScore": 2.8,
              "impactScore": 3.4,
              "source": "cna@vuldb.com",
              "type": "Secondary"
            }
          ]
        },
        "published": "2023-04-28T14:15:10.977",
        "references": [
          {
            "source": "cna@vuldb.com",
            "tags": [
              "Exploit",
              "Third Party Advisory"
            ],
            "url": "https://github.com/leetsun/IoT/tree/main/EdgeRouterX/CI/5"
          },
          {
            "source": "cna@vuldb.com",
            "tags": [
              "Permissions Required",
              "Third Party Advisory"
            ],
            "url": "https://vuldb.com/?ctiid.227649"
          },
          {
            "source": "cna@vuldb.com",
            "tags": [
              "Third Party Advisory"
            ],
            "url": "https://vuldb.com/?id.227649"
          }
        ],
        "sourceIdentifier": "cna@vuldb.com",
        "vulnStatus": "Modified",
        "weaknesses": [
          {
            "description": [
              {
                "lang": "en",
                "value": "CWE-77"
              }
            ],
            "source": "cna@vuldb.com",
            "type": "Primary"
          }
        ]
      }
    }
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…

Related by attack behaviour

Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.