All information products included in https://us-cert.cisa.gov/ics are provided "as is" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.
Risk evaluation
Successful exploitation of these vulnerabilities could allow an attacker to stop the device and prevent charging, execute arbitrary commands, and access the web interface with full privileges.
Critical infrastructure sectors
Transportation
Countries/areas deployed
Worldwide
Company headquarters location
France
Recommended Practices
NCCIC reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.
Recommended Practices
NCCIC also provides a section for control systems security recommended practices on the ICS-CERT web page. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.
Recommended Practices
Additional mitigation guidance and recommended practices are publicly available on the ICS-CERT website in the Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.Organizations observing any suspected malicious activity should follow their established internal procedures and report their findings to NCCIC for tracking and correlation against other incidents.
Exploitability
No known public exploits specifically target these vulnerabilities.
{
"document": {
"acknowledgments": [
{
"names": [
"Vladimir Kononovich",
"Vyacheslav Moskvin"
],
"organization": "Positive Technologies",
"summary": "reporting these vulnerabilities to Schneider Electric"
}
],
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Disclosure is not limited",
"tlp": {
"label": "WHITE",
"url": "https://us-cert.cisa.gov/tlp/"
}
},
"lang": "en-US",
"notes": [
{
"category": "general",
"text": "This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov",
"title": "CISA Disclaimer"
},
{
"category": "legal_disclaimer",
"text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.",
"title": "Legal Notice"
},
{
"category": "summary",
"text": "Successful exploitation of these vulnerabilities could allow an attacker to stop the device and prevent charging, execute arbitrary commands, and access the web interface with full privileges.",
"title": "Risk evaluation"
},
{
"category": "other",
"text": "Transportation",
"title": "Critical infrastructure sectors"
},
{
"category": "other",
"text": "Worldwide",
"title": "Countries/areas deployed"
},
{
"category": "other",
"text": "France",
"title": "Company headquarters location"
},
{
"category": "general",
"text": "NCCIC reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "NCCIC also provides a section for control systems security recommended practices on the ICS-CERT web page. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Additional mitigation guidance and recommended practices are publicly available on the ICS-CERT website in the Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.Organizations observing any suspected malicious activity should follow their established internal procedures and report their findings to NCCIC for tracking and correlation against other incidents.",
"title": "Recommended Practices"
},
{
"category": "other",
"text": "No known public exploits specifically target these vulnerabilities.",
"title": "Exploitability"
}
],
"publisher": {
"category": "coordinator",
"contact_details": "Email: CISAservicedesk@cisa.dhs.gov;\n Toll Free: 1-888-282-0870",
"name": "CISA",
"namespace": "https://www.cisa.gov/"
},
"references": [
{
"category": "self",
"summary": "ICS Advisory ICSA-19-031-01 JSON",
"url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2019/icsa-19-031-01.json"
},
{
"category": "self",
"summary": "ICS Advisory ICSA-19-031-01 Web Version",
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-19-031-01"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-19-031-01"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/uscert/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B"
}
],
"title": "Schneider Electric EVLink Parking",
"tracking": {
"current_release_date": "2019-01-31T00:00:00.000000Z",
"generator": {
"engine": {
"name": "CISA CSAF Generator",
"version": "1.0.0"
}
},
"id": "ICSA-19-031-01",
"initial_release_date": "2019-01-31T00:00:00.000000Z",
"revision_history": [
{
"date": "2019-01-31T00:00:00.000000Z",
"legacy_version": "Initial",
"number": "1",
"summary": "ICSA-19-031-01 Schneider Electric EVLink Parking"
}
],
"status": "final",
"version": "1"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c= 3.2.0-12_v1",
"product": {
"name": "EVLink Parking: Versions 3.2.0-12_v1 and prior",
"product_id": "CSAFPID-0001"
}
}
],
"category": "product_name",
"name": "EVLink Parking"
}
],
"category": "vendor",
"name": "Schneider Electric Software, LLC"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2018-7800",
"cwe": {
"id": "CWE-798",
"name": "Use of Hard-coded Credentials"
},
"notes": [
{
"category": "summary",
"text": "A hard-coded credentials vulnerability exists that could enable an attacker to gain access to the device.CVE-2018-7800 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H).",
"title": "Vulnerability Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"references": [
{
"category": "external",
"summary": "web.nvd.nist.gov",
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2018-7800"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Schneider Electric recommends users setup a firewall to restrict remote access to the charging stations by unauthorized users. A software update is also available for download to mitigate these vulnerabilities",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://www.schneider-electric.com/en/download/range/60850-EVlink%20Parking/?docTypeGroup=3541958-Software/Firmware"
},
{
"category": "mitigation",
"details": "For more information see Schneider Electric\u0027s security notification",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2018-354-01/"
},
{
"category": "mitigation",
"details": "Locate control and safety system networks and remote devices behind firewalls, and isolate them from the business network.",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "Physical controls should be in place so that no unauthorized person would have access to the ICS and safety controllers, peripheral equipment or the ICS and safety networks.",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "All controllers should reside in locked cabinets and never be left in the \u201cProgram\u201d mode.",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "All programming software should be kept in locked cabinets and should never be connected to any network other than the network for the devices that it is intended.",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "All methods of mobile data exchange with the isolated network such as CDs, USB drives, etc. should be scanned before use in the terminals or any node connected to these networks.",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "Laptops that have connected to any other network besides the intended network should never be allowed to connect to the safety or control networks without proper sanitation.",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "Minimize network exposure for all control system devices and/or systems, and ensure that they are not accessible from the Internet.",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "When remote access is required, use secure methods, such as virtual private networks (VPNs), recognizing that VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize that VPN is only as secure as the connected devices.",
"product_ids": [
"CSAFPID-0001"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"products": [
"CSAFPID-0001"
]
}
]
},
{
"cve": "CVE-2018-7801",
"cwe": {
"id": "CWE-94",
"name": "Improper Control of Generation of Code (\u0027Code Injection\u0027)"
},
"notes": [
{
"category": "summary",
"text": "A code injection vulnerability exists that could allow remote code execution with maximum privileges.CVE-2018-7801 has been assigned to this vulnerability. A CVSS v3 base score of 8.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).",
"title": "Vulnerability Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"references": [
{
"category": "external",
"summary": "web.nvd.nist.gov",
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2018-7801"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Schneider Electric recommends users setup a firewall to restrict remote access to the charging stations by unauthorized users. A software update is also available for download to mitigate these vulnerabilities",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://www.schneider-electric.com/en/download/range/60850-EVlink%20Parking/?docTypeGroup=3541958-Software/Firmware"
},
{
"category": "mitigation",
"details": "For more information see Schneider Electric\u0027s security notification",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2018-354-01/"
},
{
"category": "mitigation",
"details": "Locate control and safety system networks and remote devices behind firewalls, and isolate them from the business network.",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "Physical controls should be in place so that no unauthorized person would have access to the ICS and safety controllers, peripheral equipment or the ICS and safety networks.",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "All controllers should reside in locked cabinets and never be left in the \u201cProgram\u201d mode.",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "All programming software should be kept in locked cabinets and should never be connected to any network other than the network for the devices that it is intended.",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "All methods of mobile data exchange with the isolated network such as CDs, USB drives, etc. should be scanned before use in the terminals or any node connected to these networks.",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "Laptops that have connected to any other network besides the intended network should never be allowed to connect to the safety or control networks without proper sanitation.",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "Minimize network exposure for all control system devices and/or systems, and ensure that they are not accessible from the Internet.",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "When remote access is required, use secure methods, such as virtual private networks (VPNs), recognizing that VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize that VPN is only as secure as the connected devices.",
"product_ids": [
"CSAFPID-0001"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"products": [
"CSAFPID-0001"
]
}
]
},
{
"cve": "CVE-2018-7802",
"cwe": {
"id": "CWE-89",
"name": "Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)"
},
"notes": [
{
"category": "summary",
"text": "A SQL injection vulnerability exists that could give an attacker access to the web interface with full privileges.CVE-2018-7802 has been assigned to this vulnerability. A CVSS v3 base score of 6.4 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:L/UI:N/S:C/C:L/I:L/A:N).",
"title": "Vulnerability Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"references": [
{
"category": "external",
"summary": "web.nvd.nist.gov",
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2018-7802"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:C/C:L/I:L/A:N"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Schneider Electric recommends users setup a firewall to restrict remote access to the charging stations by unauthorized users. A software update is also available for download to mitigate these vulnerabilities",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://www.schneider-electric.com/en/download/range/60850-EVlink%20Parking/?docTypeGroup=3541958-Software/Firmware"
},
{
"category": "mitigation",
"details": "For more information see Schneider Electric\u0027s security notification",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2018-354-01/"
},
{
"category": "mitigation",
"details": "Locate control and safety system networks and remote devices behind firewalls, and isolate them from the business network.",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "Physical controls should be in place so that no unauthorized person would have access to the ICS and safety controllers, peripheral equipment or the ICS and safety networks.",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "All controllers should reside in locked cabinets and never be left in the \u201cProgram\u201d mode.",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "All programming software should be kept in locked cabinets and should never be connected to any network other than the network for the devices that it is intended.",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "All methods of mobile data exchange with the isolated network such as CDs, USB drives, etc. should be scanned before use in the terminals or any node connected to these networks.",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "Laptops that have connected to any other network besides the intended network should never be allowed to connect to the safety or control networks without proper sanitation.",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "Minimize network exposure for all control system devices and/or systems, and ensure that they are not accessible from the Internet.",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "mitigation",
"details": "When remote access is required, use secure methods, such as virtual private networks (VPNs), recognizing that VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize that VPN is only as secure as the connected devices.",
"product_ids": [
"CSAFPID-0001"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 6.4,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:C/C:L/I:L/A:N",
"version": "3.0"
},
"products": [
"CSAFPID-0001"
]
}
]
}
]
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…