Summary
Siemens JT Open, JT Utilities, and Parasolid

Notes

CISA Disclaimer
This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov
Legal Notice
All information products included in https://us-cert.cisa.gov/ics are provided "as is" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.
Risk evaluation
Successful exploitation of these vulnerabilities could allow an attacker to trick a user in to opening a malicious JT file with any of the affected products, which could cause the application to crash or lead to arbitrary code execution.
Critical infrastructure sectors
Multiple Sectors
Countries/areas deployed
Worldwide
Company headquarters location
Germany
Recommended Practices
CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.
Recommended Practices
CISA also provides a section for control systems security recommended practices on the ICS webpage at cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.
Recommended Practices
Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.
Recommended Practices
Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.
Recommended Practices
No known public exploits specifically target these vulnerabilities. These vulnerabilities are not exploitable remotely.
Additional Resources
For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories



{
  "document": {
    "acknowledgments": [
      {
        "names": [
          "Michael Heinzl"
        ],
        "summary": "reporting these vulnerabilities to Siemens"
      }
    ],
    "category": "csaf_security_advisory",
    "csaf_version": "2.0",
    "distribution": {
      "text": "Disclosure is not limited",
      "tlp": {
        "label": "WHITE",
        "url": "https://us-cert.cisa.gov/tlp/"
      }
    },
    "lang": "en-US",
    "notes": [
      {
        "category": "general",
        "text": "This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov",
        "title": "CISA Disclaimer"
      },
      {
        "category": "legal_disclaimer",
        "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.",
        "title": "Legal Notice"
      },
      {
        "category": "summary",
        "text": "Successful exploitation of these vulnerabilities could allow an attacker to trick a user in to opening a malicious JT file with any of the affected products, which could cause the application to crash or lead to arbitrary code execution.",
        "title": "Risk evaluation"
      },
      {
        "category": "other",
        "text": "Multiple Sectors",
        "title": "Critical infrastructure sectors"
      },
      {
        "category": "other",
        "text": "Worldwide",
        "title": "Countries/areas deployed"
      },
      {
        "category": "other",
        "text": "Germany",
        "title": "Company headquarters location"
      },
      {
        "category": "general",
        "text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.",
        "title": "Recommended Practices"
      },
      {
        "category": "general",
        "text": "CISA also provides a section for control systems security recommended practices on the ICS webpage at cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.",
        "title": "Recommended Practices"
      },
      {
        "category": "general",
        "text": "Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.",
        "title": "Recommended Practices"
      },
      {
        "category": "general",
        "text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.",
        "title": "Recommended Practices"
      },
      {
        "category": "general",
        "text": "No known public exploits specifically target these vulnerabilities. These vulnerabilities are not exploitable remotely.",
        "title": "Recommended Practices"
      },
      {
        "category": "general",
        "text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories",
        "title": "Additional Resources"
      }
    ],
    "publisher": {
      "category": "coordinator",
      "contact_details": "Email: CISAservicedesk@cisa.dhs.gov;\n Toll Free: 1-888-282-0870",
      "name": "CISA",
      "namespace": "https://www.cisa.gov/"
    },
    "references": [
      {
        "category": "external",
        "summary": "SSA-836777: JT File Parsing Vulnerabilities in JT Open, JT Utilities and Parasolid - CSAF Version",
        "url": "https://cert-portal.siemens.com/productcert/csaf/ssa-836777.json"
      },
      {
        "category": "self",
        "summary": "ICS Advisory ICSA-23-047-12 JSON",
        "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2023/icsa-23-047-12.json"
      },
      {
        "category": "self",
        "summary": "ICS Advisory ICSA-23-047-12 Web Version",
        "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-047-12"
      },
      {
        "category": "external",
        "summary": "SSA-836777: JT File Parsing Vulnerabilities in JT Open, JT Utilities and Parasolid - PDF Version",
        "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-836777.pdf"
      },
      {
        "category": "external",
        "summary": "SSA-836777: JT File Parsing Vulnerabilities in JT Open, JT Utilities and Parasolid - TXT Version",
        "url": "https://cert-portal.siemens.com/productcert/txt/ssa-836777.txt"
      }
    ],
    "title": "Siemens JT Open, JT Utilities, and Parasolid",
    "tracking": {
      "current_release_date": "2023-02-20T16:14:40.053999Z",
      "generator": {
        "engine": {
          "name": "CISA CSAF Generator",
          "version": "1.0.0"
        }
      },
      "id": "ICSA-23-047-12",
      "initial_release_date": "2023-02-20T16:14:40.053999Z",
      "revision_history": [
        {
          "date": "2023-02-20T16:14:40.053999Z",
          "legacy_version": "1",
          "number": "1",
          "summary": "CSAF Creation Date"
        }
      ],
      "status": "final",
      "version": "1"
    }
  },
  "product_tree": {
    "branches": [
      {
        "branches": [
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "\u003c V11.2.3.0",
                "product": {
                  "name": "JT Open",
                  "product_id": "CSAFPID-0001"
                }
              }
            ],
            "category": "product_name",
            "name": "JT Open"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "\u003c V13.2.3.0",
                "product": {
                  "name": "JT Utilities",
                  "product_id": "CSAFPID-0002"
                }
              }
            ],
            "category": "product_name",
            "name": "JT Utilities"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "\u003c V34.0.252",
                "product": {
                  "name": "Parasolid V34.0",
                  "product_id": "CSAFPID-0003"
                }
              },
              {
                "category": "product_version_range",
                "name": "\u003c V34.0.254",
                "product": {
                  "name": "Parasolid V34.0",
                  "product_id": "CSAFPID-0004"
                }
              }
            ],
            "category": "product_name",
            "name": "Parasolid V34.0"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "\u003c V34.1.242",
                "product": {
                  "name": "Parasolid V34.1",
                  "product_id": "CSAFPID-0005"
                }
              }
            ],
            "category": "product_name",
            "name": "Parasolid V34.1"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "\u003c V35.0.170",
                "product": {
                  "name": "Parasolid V35.0",
                  "product_id": "CSAFPID-0006"
                }
              }
            ],
            "category": "product_name",
            "name": "Parasolid V35.0"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "\u003c V35.1.150",
                "product": {
                  "name": "Parasolid V35.1",
                  "product_id": "CSAFPID-0007"
                }
              }
            ],
            "category": "product_name",
            "name": "Parasolid V35.1"
          }
        ],
        "category": "vendor",
        "name": "Siemens"
      }
    ]
  },
  "vulnerabilities": [
    {
      "cve": "CVE-2022-47936",
      "cwe": {
        "id": "CWE-121",
        "name": "Stack-based Buffer Overflow"
      },
      "notes": [
        {
          "category": "summary",
          "text": "The affected application contains a stack overflow vulnerability while parsing specially crafted JT files. This could allow an attacker to execute code in the context of the current process.",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "CSAFPID-0001",
          "CSAFPID-0002",
          "CSAFPID-0003",
          "CSAFPID-0005",
          "CSAFPID-0006",
          "CSAFPID-0007"
        ]
      },
      "references": [
        {
          "category": "external",
          "summary": "web.nvd.nist.gov",
          "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-47936"
        },
        {
          "category": "external",
          "summary": "www.first.org",
          "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H"
        }
      ],
      "remediations": [
        {
          "category": "vendor_fix",
          "details": "Update to V11.2.3.0 or later version",
          "product_ids": [
            "CSAFPID-0001"
          ],
          "url": "https://support.sw.siemens.com/"
        },
        {
          "category": "vendor_fix",
          "details": "Update to V13.2.3.0 or later version",
          "product_ids": [
            "CSAFPID-0002"
          ],
          "url": "https://support.sw.siemens.com/"
        },
        {
          "category": "vendor_fix",
          "details": "Update to V34.0.252 or later version",
          "product_ids": [
            "CSAFPID-0003"
          ],
          "url": "https://support.sw.siemens.com/"
        },
        {
          "category": "vendor_fix",
          "details": "Update to V34.1.242 or later version",
          "product_ids": [
            "CSAFPID-0005"
          ],
          "url": "https://support.sw.siemens.com/"
        },
        {
          "category": "vendor_fix",
          "details": "Update to V35.0.170 or later version",
          "product_ids": [
            "CSAFPID-0006"
          ],
          "url": "https://support.sw.siemens.com/"
        },
        {
          "category": "vendor_fix",
          "details": "Update to V35.1.150 or later version",
          "product_ids": [
            "CSAFPID-0007"
          ],
          "url": "https://support.sw.siemens.com/"
        },
        {
          "category": "workaround",
          "details": "Do not open untrusted files using Parasolid, JT Open Toolkit or JT Utilities",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002",
            "CSAFPID-0003",
            "CSAFPID-0005",
            "CSAFPID-0006",
            "CSAFPID-0007"
          ]
        },
        {
          "category": "mitigation",
          "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002",
            "CSAFPID-0003",
            "CSAFPID-0005",
            "CSAFPID-0006",
            "CSAFPID-0007"
          ]
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          },
          "products": [
            "CSAFPID-0001",
            "CSAFPID-0002",
            "CSAFPID-0003",
            "CSAFPID-0005",
            "CSAFPID-0006",
            "CSAFPID-0007"
          ]
        }
      ],
      "title": "CVE-2022-47936"
    },
    {
      "cve": "CVE-2022-47977",
      "cwe": {
        "id": "CWE-119",
        "name": "Improper Restriction of Operations within the Bounds of a Memory Buffer"
      },
      "notes": [
        {
          "category": "summary",
          "text": "The affected application contains a memory corruption vulnerability while parsing specially crafted JT files. This could allow an attacker to execute code in the context of the current process.",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "CSAFPID-0001",
          "CSAFPID-0002"
        ]
      },
      "references": [
        {
          "category": "external",
          "summary": "web.nvd.nist.gov",
          "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-47977"
        },
        {
          "category": "external",
          "summary": "www.first.org",
          "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H"
        }
      ],
      "remediations": [
        {
          "category": "vendor_fix",
          "details": "Update to V11.2.3.0 or later version",
          "product_ids": [
            "CSAFPID-0001"
          ],
          "url": "https://support.sw.siemens.com/"
        },
        {
          "category": "vendor_fix",
          "details": "Update to V13.2.3.0 or later version",
          "product_ids": [
            "CSAFPID-0002"
          ],
          "url": "https://support.sw.siemens.com/"
        },
        {
          "category": "workaround",
          "details": "Do not open untrusted files using Parasolid, JT Open Toolkit or JT Utilities",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002"
          ]
        },
        {
          "category": "mitigation",
          "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity",
          "product_ids": [
            "CSAFPID-0001",
            "CSAFPID-0002"
          ]
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          },
          "products": [
            "CSAFPID-0001",
            "CSAFPID-0002"
          ]
        }
      ],
      "title": "CVE-2022-47977"
    },
    {
      "cve": "CVE-2023-25140",
      "cwe": {
        "id": "CWE-125",
        "name": "Out-of-bounds Read"
      },
      "notes": [
        {
          "category": "summary",
          "text": "The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process.",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "CSAFPID-0004",
          "CSAFPID-0005",
          "CSAFPID-0006",
          "CSAFPID-0007"
        ]
      },
      "references": [
        {
          "category": "external",
          "summary": "web.nvd.nist.gov",
          "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2023-25140"
        },
        {
          "category": "external",
          "summary": "www.first.org",
          "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H"
        }
      ],
      "remediations": [
        {
          "category": "vendor_fix",
          "details": "Update to V34.0.254 or later version",
          "product_ids": [
            "CSAFPID-0004"
          ],
          "url": "https://support.sw.siemens.com/"
        },
        {
          "category": "vendor_fix",
          "details": "Update to V34.1.242 or later version",
          "product_ids": [
            "CSAFPID-0005"
          ],
          "url": "https://support.sw.siemens.com/"
        },
        {
          "category": "vendor_fix",
          "details": "Update to V35.0.170 or later version",
          "product_ids": [
            "CSAFPID-0006"
          ],
          "url": "https://support.sw.siemens.com/"
        },
        {
          "category": "vendor_fix",
          "details": "Update to V35.1.150 or later version",
          "product_ids": [
            "CSAFPID-0007"
          ],
          "url": "https://support.sw.siemens.com/"
        },
        {
          "category": "workaround",
          "details": "Do not open untrusted files using Parasolid, JT Open Toolkit or JT Utilities",
          "product_ids": [
            "CSAFPID-0004",
            "CSAFPID-0005",
            "CSAFPID-0006",
            "CSAFPID-0007"
          ]
        },
        {
          "category": "mitigation",
          "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity",
          "product_ids": [
            "CSAFPID-0004",
            "CSAFPID-0005",
            "CSAFPID-0006",
            "CSAFPID-0007"
          ]
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          },
          "products": [
            "CSAFPID-0004",
            "CSAFPID-0005",
            "CSAFPID-0006",
            "CSAFPID-0007"
          ]
        }
      ],
      "title": "CVE-2023-25140"
    }
  ]
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading...

Loading...

Loading...

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.