CVE-2022-47936
Vulnerability from cvelistv5
Published
2023-02-14 10:36
Modified
2024-08-03 15:02
Severity
Summary
A vulnerability has been identified in JT Open (All versions < V11.2.3.0), JT Utilities (All versions < V13.2.3.0), Parasolid V34.0 (All versions < V34.0.252), Parasolid V34.1 (All versions < V34.1.242), Parasolid V35.0 (All versions < V35.0.170), Parasolid V35.1 (All versions < V35.1.150). The affected application contains a stack overflow vulnerability while parsing specially crafted JT files. This could allow an attacker to execute code in the context of the current process.
References
Source | URL | Tags |
---|---|---|
productcert@siemens.com | https://cert-portal.siemens.com/productcert/pdf/ssa-836777.pdf | Vendor Advisory |
Impacted products
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T15:02:36.549Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-836777.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "JT Open", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V11.2.3.0" } ] }, { "defaultStatus": "unknown", "product": "JT Utilities", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V13.2.3.0" } ] }, { "defaultStatus": "unknown", "product": "Parasolid V34.0", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V34.0.252" } ] }, { "defaultStatus": "unknown", "product": "Parasolid V34.1", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V34.1.242" } ] }, { "defaultStatus": "unknown", "product": "Parasolid V35.0", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V35.0.170" } ] }, { "defaultStatus": "unknown", "product": "Parasolid V35.1", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V35.1.150" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in JT Open (All versions \u003c V11.2.3.0), JT Utilities (All versions \u003c V13.2.3.0), Parasolid V34.0 (All versions \u003c V34.0.252), Parasolid V34.1 (All versions \u003c V34.1.242), Parasolid V35.0 (All versions \u003c V35.0.170), Parasolid V35.1 (All versions \u003c V35.1.150). The affected application contains a stack overflow vulnerability while parsing specially crafted JT files. This could allow an attacker to execute code in the context of the current process." } ], "metrics": [ { "cvssV3_1": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-121", "description": "CWE-121: Stack-based Buffer Overflow", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-02-15T09:24:56.841Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-836777.pdf" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2022-47936", "datePublished": "2023-02-14T10:36:21.369Z", "dateReserved": "2022-12-23T11:29:16.433Z", "dateUpdated": "2024-08-03T15:02:36.549Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2022-47936\",\"sourceIdentifier\":\"productcert@siemens.com\",\"published\":\"2023-02-14T11:15:14.473\",\"lastModified\":\"2023-02-22T16:12:32.210\",\"vulnStatus\":\"Analyzed\",\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability has been identified in JT Open (All versions \u003c V11.2.3.0), JT Utilities (All versions \u003c V13.2.3.0), Parasolid V34.0 (All versions \u003c V34.0.252), Parasolid V34.1 (All versions \u003c V34.1.242), Parasolid V35.0 (All versions \u003c V35.0.170), Parasolid V35.1 (All versions \u003c V35.1.150). The affected application contains a stack overflow vulnerability while parsing specially crafted JT files. This could allow an attacker to execute code in the context of the current process.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\",\"baseScore\":7.8,\"baseSeverity\":\"HIGH\"},\"exploitabilityScore\":1.8,\"impactScore\":5.9},{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\",\"baseScore\":7.8,\"baseSeverity\":\"HIGH\"},\"exploitabilityScore\":1.8,\"impactScore\":5.9}]},\"weaknesses\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-121\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:jt_open_toolkit:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"11.2.3.0\",\"matchCriteriaId\":\"33C7875E-FA42-4163-9395-B5A06E698328\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:jt_utilities:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"11.2.3.0\",\"matchCriteriaId\":\"7300A3A0-744A-4D5A-A1CD-D83A1FE97A0B\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:parasolid:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"34.0\",\"versionEndExcluding\":\"34.0.252\",\"matchCriteriaId\":\"F0D9079D-6138-4602-A982-9BC4ECBC35E7\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:parasolid:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"34.1\",\"versionEndExcluding\":\"34.1.242\",\"matchCriteriaId\":\"4C486991-A1C0-4815-AAD6-163464D711AA\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:parasolid:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"35.0\",\"versionEndExcluding\":\"35.0.170\",\"matchCriteriaId\":\"EA2114FD-BB07-4C24-98B1-928A510565BB\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:parasolid:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"35.1\",\"versionEndExcluding\":\"35.1.150\",\"matchCriteriaId\":\"5C98612B-63DF-473C-AF6E-CF3740356D5B\"}]}]}],\"references\":[{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-836777.pdf\",\"source\":\"productcert@siemens.com\",\"tags\":[\"Vendor Advisory\"]}]}}" } }
Loading...