icsa-24-193-02
Vulnerability from csaf_cisa
Published
2024-07-09 00:00
Modified
2024-12-10 00:00
Summary
Siemens RUGGEDCOM APE 1808

Notes

Summary
Fortinet has published information on vulnerabilities in FORTIOS. This advisory lists the related Siemens Industrial products. Siemens has released a new version of Fortigate NGFW for RUGGEDCOM APE1808 and recommends to update to the latest version. Siemens recommends to consult and implement the workarounds provided in Fortinet's upstream security notifications.
General Recommendations
As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity
Additional Resources
For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories
Terms of Use
The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use.
Legal Notice
All information products included in https://us-cert.cisa.gov/ics are provided "as is" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.
Advisory Conversion Disclaimer
This CISA CSAF advisory was converted from Siemens ProductCERT's CSAF advisory.
Critical infrastructure sectors
Communications, Critical Manufacturing, Energy, Transportation Systems
Countries/areas deployed
Worldwide
Company headquarters location
Germany
Recommended Practices
CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability.
Recommended Practices
Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.
Recommended Practices
Locate control system networks and remote devices behind firewalls and isolate them from business networks.
Recommended Practices
When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.
Recommended Practices
CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.
Recommended Practices
CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.
Recommended Practices
CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.
Recommended Practices
Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.



{
   document: {
      acknowledgments: [
         {
            organization: "Siemens ProductCERT",
            summary: "reporting these vulnerabilities to CISA.",
         },
      ],
      category: "csaf_security_advisory",
      csaf_version: "2.0",
      distribution: {
         text: "Disclosure is not limited",
         tlp: {
            label: "WHITE",
            url: "https://us-cert.cisa.gov/tlp/",
         },
      },
      lang: "en",
      notes: [
         {
            category: "summary",
            text: "Fortinet has published information on vulnerabilities in FORTIOS. This advisory lists the related Siemens Industrial products.\nSiemens has released a new version of Fortigate NGFW for RUGGEDCOM APE1808 and recommends to update to the latest version. Siemens recommends to consult and implement the workarounds provided in Fortinet's upstream security notifications.",
            title: "Summary",
         },
         {
            category: "general",
            text: "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity",
            title: "General Recommendations",
         },
         {
            category: "general",
            text: "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories",
            title: "Additional Resources",
         },
         {
            category: "legal_disclaimer",
            text: "The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use.",
            title: "Terms of Use",
         },
         {
            category: "legal_disclaimer",
            text: "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.",
            title: "Legal Notice",
         },
         {
            category: "other",
            text: "This CISA CSAF advisory was converted from Siemens ProductCERT's CSAF advisory.",
            title: "Advisory Conversion Disclaimer",
         },
         {
            category: "other",
            text: "Communications, Critical Manufacturing, Energy, Transportation Systems",
            title: "Critical infrastructure sectors",
         },
         {
            category: "other",
            text: "Worldwide",
            title: "Countries/areas deployed",
         },
         {
            category: "other",
            text: "Germany",
            title: "Company headquarters location",
         },
         {
            category: "general",
            text: "CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability.",
            title: "Recommended Practices",
         },
         {
            category: "general",
            text: "Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.",
            title: "Recommended Practices",
         },
         {
            category: "general",
            text: "Locate control system networks and remote devices behind firewalls and isolate them from business networks.",
            title: "Recommended Practices",
         },
         {
            category: "general",
            text: "When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.",
            title: "Recommended Practices",
         },
         {
            category: "general",
            text: "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.",
            title: "Recommended Practices",
         },
         {
            category: "general",
            text: "CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.",
            title: "Recommended Practices",
         },
         {
            category: "general",
            text: "CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.",
            title: "Recommended Practices",
         },
         {
            category: "general",
            text: "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.",
            title: "Recommended Practices",
         },
      ],
      publisher: {
         category: "other",
         contact_details: "central@cisa.dhs.gov",
         name: "CISA",
         namespace: "https://www.cisa.gov/",
      },
      references: [
         {
            category: "self",
            summary: "SSA-698820: Multiple Vulnerabilities in Fortigate NGFW Before V7.4.4 on RUGGEDCOM APE1808 Devices - CSAF Version",
            url: "https://cert-portal.siemens.com/productcert/csaf/ssa-698820.json",
         },
         {
            category: "self",
            summary: "SSA-698820: Multiple Vulnerabilities in Fortigate NGFW Before V7.4.4 on RUGGEDCOM APE1808 Devices - HTML Version",
            url: "https://cert-portal.siemens.com/productcert/html/ssa-698820.html",
         },
         {
            category: "self",
            summary: "ICS Advisory ICSA-24-193-02 JSON",
            url: "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2024/icsa-24-193-02.json",
         },
         {
            category: "self",
            summary: "ICS Advisory ICSA-24-193-02 - Web Version",
            url: "https://www.cisa.gov/news-events/ics-advisories/icsa-24-193-02",
         },
         {
            category: "external",
            summary: "Recommended Practices",
            url: "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01",
         },
         {
            category: "external",
            summary: "Recommended Practices",
            url: "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices",
         },
         {
            category: "external",
            summary: "Recommended Practices",
            url: "https://www.cisa.gov/topics/industrial-control-systems",
         },
         {
            category: "external",
            summary: "Recommended Practices",
            url: "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf",
         },
         {
            category: "external",
            summary: "Recommended Practices",
            url: "https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf",
         },
         {
            category: "external",
            summary: "Recommended Practices",
            url: "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B",
         },
      ],
      title: "Siemens RUGGEDCOM APE 1808",
      tracking: {
         current_release_date: "2024-12-10T00:00:00.000000Z",
         generator: {
            engine: {
               name: "CISA CSAF Generator",
               version: "1.0.0",
            },
         },
         id: "ICSA-24-193-02",
         initial_release_date: "2024-07-09T00:00:00.000000Z",
         revision_history: [
            {
               date: "2024-07-09T00:00:00.000000Z",
               legacy_version: "1.0",
               number: "1",
               summary: "Publication Date",
            },
            {
               date: "2024-08-13T00:00:00.000000Z",
               legacy_version: "1.1",
               number: "2",
               summary: "Updated CVE-2024-23111 description and added newly published CVE-2024-26006 and CVE-2024-26015",
            },
            {
               date: "2024-09-10T00:00:00.000000Z",
               legacy_version: "1.2",
               number: "3",
               summary: "Added newly published upstream vulnerability CVE-2024-36505",
            },
            {
               date: "2024-10-08T00:00:00.000000Z",
               legacy_version: "1.3",
               number: "4",
               summary: "Added fix for Fortinet NGFW as released from Siemens for RUGGEDCOM APE1808; added mitigations for CVE-2024-26006 and CVE-2024-26010",
            },
            {
               date: "2024-12-10T00:00:00.000000Z",
               legacy_version: "1.4",
               number: "5",
               summary: "Added newly published upstream vulnerabilities CVE-2024-33510, CVE-2023-50176, CVE-2024-26011",
            },
         ],
         status: "final",
         version: "5",
      },
   },
   product_tree: {
      branches: [
         {
            branches: [
               {
                  branches: [
                     {
                        category: "product_version_range",
                        name: "vers:all/*",
                        product: {
                           name: "RUGGEDCOM APE1808",
                           product_id: "CSAFPID-0001",
                        },
                     },
                  ],
                  category: "product_name",
                  name: "RUGGEDCOM APE1808",
               },
            ],
            category: "vendor",
            name: "Siemens",
         },
      ],
   },
   vulnerabilities: [
      {
         cve: "CVE-2023-46720",
         cwe: {
            id: "CWE-121",
            name: "Stack-based Buffer Overflow",
         },
         notes: [
            {
               category: "summary",
               text: "A stack-based buffer overflow in Fortinet FortiOS version 7.4.0 through 7.4.1 and 7.2.0 through 7.2.7 and 7.0.0 through 7.0.12 and 6.4.6 through 6.4.15 and 6.2.9 through 6.2.16 and 6.0.13 through 6.0.18 allows attacker to execute unauthorized code or commands via specially crafted CLI commands.",
               title: "Summary",
            },
         ],
         product_status: {
            known_affected: [
               "CSAFPID-0001",
            ],
         },
         remediations: [
            {
               category: "vendor_fix",
               details: "Update Fortigate NGFW to V7.4.4. Contact customer support to receive patch and update information.",
               product_ids: [
                  "CSAFPID-0001",
               ],
            },
         ],
         scores: [
            {
               cvss_v3: {
                  baseScore: 6.7,
                  baseSeverity: "MEDIUM",
                  vectorString: "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
                  version: "3.1",
               },
               products: [
                  "CSAFPID-0001",
               ],
            },
         ],
         title: "CVE-2023-46720",
      },
      {
         cve: "CVE-2023-50176",
         cwe: {
            id: "CWE-384",
            name: "Session Fixation",
         },
         notes: [
            {
               category: "summary",
               text: "A session fixation in Fortinet FortiOS version 7.4.0 through 7.4.3 and 7.2.0 through 7.2.7 and 7.0.0 through 7.0.13 allows attacker to execute unauthorized code or commands via phishing SAML authentication link.",
               title: "Summary",
            },
         ],
         product_status: {
            known_affected: [
               "CSAFPID-0001",
            ],
         },
         remediations: [
            {
               category: "vendor_fix",
               details: "Update Fortigate NGFW to V7.4.4. Contact customer support to receive patch and update information.",
               product_ids: [
                  "CSAFPID-0001",
               ],
            },
         ],
         scores: [
            {
               cvss_v3: {
                  baseScore: 7.5,
                  baseSeverity: "HIGH",
                  vectorString: "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P",
                  version: "3.1",
               },
               products: [
                  "CSAFPID-0001",
               ],
            },
         ],
         title: "CVE-2023-50176",
      },
      {
         cve: "CVE-2024-21754",
         cwe: {
            id: "CWE-916",
            name: "Use of Password Hash With Insufficient Computational Effort",
         },
         notes: [
            {
               category: "summary",
               text: "A use of password hash with insufficient computational effort vulnerability [CWE-916] affecting FortiOS version 7.4.3 and below, 7.2 all versions, 7.0 all versions, 6.4 all versions and FortiProxy version 7.4.2 and below, 7.2 all versions, 7.0 all versions, 2.0 all versions may allow a privileged attacker with super-admin profile and CLI access to decrypting the backup file.",
               title: "Summary",
            },
         ],
         product_status: {
            known_affected: [
               "CSAFPID-0001",
            ],
         },
         remediations: [
            {
               category: "vendor_fix",
               details: "Update Fortigate NGFW to V7.4.4. Contact customer support to receive patch and update information.",
               product_ids: [
                  "CSAFPID-0001",
               ],
            },
         ],
         scores: [
            {
               cvss_v3: {
                  baseScore: 1.8,
                  baseSeverity: "LOW",
                  vectorString: "CVSS:3.1/AV:L/AC:H/PR:H/UI:R/S:U/C:L/I:N/A:N/E:P/RL:O/RC:C",
                  version: "3.1",
               },
               products: [
                  "CSAFPID-0001",
               ],
            },
         ],
         title: "CVE-2024-21754",
      },
      {
         cve: "CVE-2024-23111",
         cwe: {
            id: "CWE-79",
            name: "Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')",
         },
         notes: [
            {
               category: "summary",
               text: "An improper neutralization of input during web page Generation ('Cross-site Scripting') vulnerability [CWE-79] in FortiOS version 7.4.3 and below, 7.2 all versions, 7.0 all versions, 6.4 all versions and FortiProxy version 7.4.2 and below, 7.2 all versions, 7.0 all versions, 2.0 all versions reboot page may allow a remote privileged attacker with super-admin access to execute JavaScript code via crafted HTTP GET requests.",
               title: "Summary",
            },
         ],
         product_status: {
            known_affected: [
               "CSAFPID-0001",
            ],
         },
         remediations: [
            {
               category: "vendor_fix",
               details: "Update Fortigate NGFW to V7.4.4. Contact customer support to receive patch and update information.",
               product_ids: [
                  "CSAFPID-0001",
               ],
            },
         ],
         scores: [
            {
               cvss_v3: {
                  baseScore: 6.8,
                  baseSeverity: "MEDIUM",
                  vectorString: "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
                  version: "3.1",
               },
               products: [
                  "CSAFPID-0001",
               ],
            },
         ],
         title: "CVE-2024-23111",
      },
      {
         cve: "CVE-2024-26006",
         cwe: {
            id: "CWE-79",
            name: "Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')",
         },
         notes: [
            {
               category: "summary",
               text: "An improper neutralization of input during web page Generation vulnerability [CWE-79] in FortiOS and FortiProxy's web SSL VPN UI may allow a remote unauthenticated attacker to perform a Cross-Site Scripting attack via social engineering the targeted user into bookmarking a malicious samba server, then opening the bookmark.",
               title: "Summary",
            },
         ],
         product_status: {
            known_affected: [
               "CSAFPID-0001",
            ],
         },
         remediations: [
            {
               category: "mitigation",
               details: "Disable SSL-VPN web-mode (see \nhttps://fortiguard.fortinet.com/psirt/FG-IR-23-485)",
               product_ids: [
                  "CSAFPID-0001",
               ],
            },
            {
               category: "vendor_fix",
               details: "Update Fortigate NGFW to V7.4.4. Contact customer support to receive patch and update information.",
               product_ids: [
                  "CSAFPID-0001",
               ],
            },
         ],
         scores: [
            {
               cvss_v3: {
                  baseScore: 7.5,
                  baseSeverity: "HIGH",
                  vectorString: "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
                  version: "3.1",
               },
               products: [
                  "CSAFPID-0001",
               ],
            },
         ],
         title: "CVE-2024-26006",
      },
      {
         cve: "CVE-2024-26010",
         cwe: {
            id: "CWE-121",
            name: "Stack-based Buffer Overflow",
         },
         notes: [
            {
               category: "summary",
               text: "A stack-based buffer overflow in Fortinet FortiPAM version 1.2.0, 1.1.0 through 1.1.2, 1.0.0 through 1.0.3, FortiWeb, FortiAuthenticator, FortiSwitchManager version 7.2.0 through 7.2.3, 7.0.1 through 7.0.3, FortiOS version 7.4.0 through 7.4.3, 7.2.0 through 7.2.7, 7.0.0 through 7.0.14, 6.4.0 through 6.4.15, 6.2.0 through 6.2.16, 6.0.0 through 6.0.18, FortiProxy version 7.4.0 through 7.4.2, 7.2.0 through 7.2.9, 7.0.0 through 7.0.15, 2.0.0 through 2.0.13, 1.2.0 through 1.2.13, 1.1.0 through 1.1.6, 1.0.0 through 1.0.7 allows attacker to execute unauthorized code or commands via specially crafted packets.",
               title: "Summary",
            },
         ],
         product_status: {
            known_affected: [
               "CSAFPID-0001",
            ],
         },
         remediations: [
            {
               category: "mitigation",
               details: "For each interface, remove the fgfm access (see \nhttps://www.fortiguard.com/psirt/FG-IR-24-036)",
               product_ids: [
                  "CSAFPID-0001",
               ],
            },
            {
               category: "vendor_fix",
               details: "Update Fortigate NGFW to V7.4.4. Contact customer support to receive patch and update information.",
               product_ids: [
                  "CSAFPID-0001",
               ],
            },
         ],
         scores: [
            {
               cvss_v3: {
                  baseScore: 7.5,
                  baseSeverity: "HIGH",
                  vectorString: "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
                  version: "3.1",
               },
               products: [
                  "CSAFPID-0001",
               ],
            },
         ],
         title: "CVE-2024-26010",
      },
      {
         cve: "CVE-2024-26011",
         cwe: {
            id: "CWE-306",
            name: "Missing Authentication for Critical Function",
         },
         notes: [
            {
               category: "summary",
               text: "A missing authentication for critical function in Fortinet FortiManager version 7.4.0 through 7.4.2, 7.2.0 through 7.2.4, 7.0.0 through 7.0.11, 6.4.0 through 6.4.14, FortiPAM version 1.2.0, 1.1.0 through 1.1.2, 1.0.0 through 1.0.3, FortiProxy version 7.4.0 through 7.4.2, 7.2.0 through 7.2.9, 7.0.0 through 7.0.17, 2.0.0 through 2.0.14, 1.2.0 through 1.2.13, 1.1.0 through 1.1.6, 1.0.0 through 1.0.7, FortiSwitchManager version 7.2.0 through 7.2.3, 7.0.0 through 7.0.3, FortiPortal version 6.0.0 through 6.0.14, FortiOS version 7.4.0 through 7.4.3, 7.2.0 through 7.2.7, 7.0.0 through 7.0.14, 6.4.0 through 6.4.15, 6.2.0 through 6.2.16, 6.0.0 through 6.0.18 allows attacker to execute unauthorized code or commands via specially crafted packets.",
               title: "Summary",
            },
         ],
         product_status: {
            known_affected: [
               "CSAFPID-0001",
            ],
         },
         remediations: [
            {
               category: "vendor_fix",
               details: "Update Fortigate NGFW to V7.4.4. Contact customer support to receive patch and update information.",
               product_ids: [
                  "CSAFPID-0001",
               ],
            },
         ],
         scores: [
            {
               cvss_v3: {
                  baseScore: 5.3,
                  baseSeverity: "MEDIUM",
                  vectorString: "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N/E:F/RL:U/RC:C",
                  version: "3.1",
               },
               products: [
                  "CSAFPID-0001",
               ],
            },
         ],
         title: "CVE-2024-26011",
      },
      {
         cve: "CVE-2024-26015",
         cwe: {
            id: "CWE-1389",
            name: "Incorrect Parsing of Numbers with Different Radices",
         },
         notes: [
            {
               category: "summary",
               text: "An incorrect parsing of numbers with different radices vulnerability [CWE-1389] in FortiProxy version 7.4.3 and below, version 7.2.10 and below, version 7.0.17 and below and FortiOS version 7.4.3 and below, version 7.2.8 and below, version 7.0.15 and below IP address validation feature may permit an unauthenticated attacker to bypass the IP blocklist via crafted requests.",
               title: "Summary",
            },
         ],
         product_status: {
            known_affected: [
               "CSAFPID-0001",
            ],
         },
         remediations: [
            {
               category: "vendor_fix",
               details: "Update Fortigate NGFW to V7.4.4. Contact customer support to receive patch and update information.",
               product_ids: [
                  "CSAFPID-0001",
               ],
            },
         ],
         scores: [
            {
               cvss_v3: {
                  baseScore: 3.4,
                  baseSeverity: "LOW",
                  vectorString: "CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:C/C:N/I:L/A:N/E:F/RL:W/RC:R",
                  version: "3.1",
               },
               products: [
                  "CSAFPID-0001",
               ],
            },
         ],
         title: "CVE-2024-26015",
      },
      {
         cve: "CVE-2024-33510",
         cwe: {
            id: "CWE-358",
            name: "Improperly Implemented Security Check for Standard",
         },
         notes: [
            {
               category: "summary",
               text: "An improper neutralization of special elements in output used by a downstream component ('Injection') vulnerability [CWE-74] in FortiOS version 7.4.3 and below, version 7.2.8 and below, version 7.0.16 and below; FortiProxy version 7.4.3 and below, version 7.2.9 and below, version 7.0.16 and below; FortiSASE version 24.2.b SSL-VPN web user interface may allow a remote unauthenticated attacker to perform phishing attempts via crafted requests.",
               title: "Summary",
            },
         ],
         product_status: {
            known_affected: [
               "CSAFPID-0001",
            ],
         },
         remediations: [
            {
               category: "vendor_fix",
               details: "Update Fortigate NGFW to V7.4.4. Contact customer support to receive patch and update information.",
               product_ids: [
                  "CSAFPID-0001",
               ],
            },
         ],
         scores: [
            {
               cvss_v3: {
                  baseScore: 4.3,
                  baseSeverity: "MEDIUM",
                  vectorString: "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:L/A:N/E:U/RL:O/RC:R",
                  version: "3.1",
               },
               products: [
                  "CSAFPID-0001",
               ],
            },
         ],
         title: "CVE-2024-33510",
      },
      {
         cve: "CVE-2024-36505",
         cwe: {
            id: "CWE-284",
            name: "Improper Access Control",
         },
         notes: [
            {
               category: "summary",
               text: "An improper access control vulnerability [CWE-284] in FortiOS 7.4.0 through 7.4.3, 7.2.5 through 7.2.7, 7.0.12 through 7.0.14 and 6.4.x may allow an attacker who has already successfully obtained write access to the underlying system (via another hypothetical exploit) to bypass the file integrity checking system.",
               title: "Summary",
            },
         ],
         product_status: {
            known_affected: [
               "CSAFPID-0001",
            ],
         },
         remediations: [
            {
               category: "vendor_fix",
               details: "Update Fortigate NGFW to V7.4.4. Contact customer support to receive patch and update information.",
               product_ids: [
                  "CSAFPID-0001",
               ],
            },
         ],
         scores: [
            {
               cvss_v3: {
                  baseScore: 5.1,
                  baseSeverity: "MEDIUM",
                  vectorString: "CVSS:3.1/AV:L/AC:H/PR:N/UI:N/S:U/C:N/I:H/A:N/E:P/RC:R",
                  version: "3.1",
               },
               products: [
                  "CSAFPID-0001",
               ],
            },
         ],
         title: "CVE-2024-36505",
      },
   ],
}


Log in or create an account to share your comment.

Security Advisory comment format.

This schema specifies the format of a comment related to a security advisory.

UUIDv4 of the comment
UUIDv4 of the Vulnerability-Lookup instance
When the comment was created originally
When the comment was last updated
Title of the comment
Description of the comment
The identifier of the vulnerability (CVE ID, GHSA-ID, PYSEC ID, etc.).



Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.