SEVD-2021-040-01

Vulnerability from csaf_se - Published: 2021-02-08 00:00 - Updated: 2021-02-08 00:00
Summary
PowerLogic Power Metering Products

Notes

General Security Recommendations
We strongly recommend the following industry cybersecurity best practices. https://www.se.com/us/en/download/document/7EN52-0390/ * Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network. * Install physical controls so no unauthorized personnel can access your industrial control and safety systems, components, peripheral equipment, and networks. * Place all controllers in locked cabinets and never leave them in the “Program” mode. * Never connect programming software to any network other than the network intended for that device. * Scan all methods of mobile data exchange with the isolated network such as CDs, USB drives, etc. before use in the terminals or any node connected to these networks. * Never allow mobile devices that have connected to any other network besides the intended network to connect to the safety or control networks without proper sanitation. * Minimize network exposure for all control system devices and systems and ensure that they are not accessible from the Internet. * When remote access is required, use secure methods, such as Virtual Private Networks (VPNs). Recognize that VPNs may have vulnerabilities and should be updated to the most current version available. Also, understand that VPNs are only as secure as the connected devices. For more information refer to the Schneider Electric Recommended Cybersecurity Best Practices document.
For More Information
This document provides an overview of the identified vulnerability or vulnerabilities and actions required to mitigate. For more details and assistance on how to protect your installation, contact your local Schneider Electric representative or Schneider Electric Industrial Cybersecurity Services: https://www.se.com/ww/en/work/solutions/cybersecurity/. These organizations will be fully aware of this situation and can support you through the process. For further information related to cybersecurity in Schneider Electric’s products, visit the company’s cybersecurity support portal page: https://www.se.com/ww/en/work/support/cybersecurity/overview.jsp
LEGAL DISCLAIMER
THIS NOTIFICATION DOCUMENT, THE INFORMATION CONTAINED HEREIN, AND ANY MATERIALS LINKED FROM IT (COLLECTIVELY, THIS “NOTIFICATION”) ARE INTENDED TO HELP PROVIDE AN OVERVIEW OF THE IDENTIFIED SITUATION AND SUGGESTED MITIGATION ACTIONS, REMEDIATION, FIX, AND/OR GENERAL SECURITY RECOMMENDATIONS AND IS PROVIDED ON AN “AS-IS” BASIS WITHOUT WARRANTY OR GUARANTEE OF ANY KIND. SCHNEIDER ELECTRIC DISCLAIMS ALL WARRANTIES RELATING TO THIS NOTIFICATION, EITHER EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. SCHNEIDER ELECTRIC MAKES NO WARRANTY THAT THE NOTIFICATION WILL RESOLVE THE IDENTIFIED SITUATION. IN NO EVENT SHALL SCHNEIDER ELECTRIC BE LIABLE FOR ANY DAMAGES OR LOSSES WHATSOEVER IN CONNECTION WITH THIS NOTIFICATION, INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF SCHNEIDER ELECTRIC HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. YOUR USE OF THIS NOTIFICATION IS AT YOUR OWN RISK, AND YOU ARE SOLELY LIABLE FOR ANY DAMAGES TO YOUR SYSTEMS OR ASSETS OR OTHER LOSSES THAT MAY RESULT FROM YOUR USE OF THIS NOTIFICATION. SCHNEIDER ELECTRIC RESERVES THE RIGHT TO UPDATE OR CHANGE THIS NOTIFICATION AT ANY TIME AND IN ITS SOLE DISCRETION
About Schneider Electric
At Schneider, we believe access to energy and digital is a basic human right. We empower all to do more with less, ensuring Life Is On everywhere, for everyone, at every moment. We provide energy and automation digital solutions for efficiency and sustainability. We combine world-leading energy technologies, real-time automation, software and services into integrated solutions for Homes, Buildings, Data Centers, Infrastructure and Industries. We are committed to unleash the infinite possibilities of an open, global, innovative community that is passionate with our Meaningful Purpose, Inclusive and Empowered values. www.se.com
Overview
Schneider Electric is aware of multiple vulnerabilities in its PowerLogic ION7400, ION7650, ION7700/73xx, ION83xx/84xx/85xx/8600, ION8650, ION8800, ION9000 and PM8000 products. The PowerLogic metering products are revenue and power quality meters for utility and industrial electrical network monitoring. Failure to apply the mitigations/remediations provided below may risk disclosure of user credentials when using HTTP or Telnet protocol or cause a user to perform an unintended action on a target device when using HTTP, which could result in unintended device behavior.
Overview
Customers should use appropriate methodologies when applying these upgrades to their devices. We strongly recommend evaluating the impact of these updates in a test and development environment prior to deployment. Contact Schneider Electric's Customer Care Center if you need assistance reverting to an older version of firmware.

{
  "document": {
    "category": "csaf_security_advisory",
    "csaf_version": "2.0",
    "distribution": {
      "text": "Public",
      "tlp": {
        "label": "WHITE"
      }
    },
    "lang": "en-US",
    "notes": [
      {
        "category": "general",
        "text": "We strongly recommend the following industry cybersecurity best practices.\n\nhttps://www.se.com/us/en/download/document/7EN52-0390/\n* Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network.\n* Install physical controls so no unauthorized personnel can access your industrial control and safety systems, components, peripheral equipment, and networks.\n* Place all controllers in locked cabinets and never leave them in the \u201cProgram\u201d mode.\n* Never connect programming software to any network other than the network intended for that device.\n* Scan all methods of mobile data exchange with the isolated network such as CDs, USB drives, etc. before use in the terminals or any node connected to these networks.\n* Never allow mobile devices that have connected to any other network besides the intended network to connect to the safety or control networks without proper sanitation.\n* Minimize network exposure for all control system devices and systems and ensure that they are not accessible from the Internet.\n* When remote access is required, use secure methods, such as Virtual Private Networks (VPNs). Recognize that VPNs may have vulnerabilities and should be updated to the most current version available. Also, understand that VPNs are only as secure as the connected devices.\nFor more information refer to the Schneider Electric Recommended Cybersecurity Best Practices document. \n",
        "title": "General Security Recommendations"
      },
      {
        "category": "general",
        "text": "This document provides an overview of the identified vulnerability or vulnerabilities and actions required to mitigate. For more details and assistance on how to protect your installation, contact your local Schneider Electric representative or Schneider Electric Industrial Cybersecurity Services: https://www.se.com/ww/en/work/solutions/cybersecurity/. These organizations will be fully aware of this situation and can support you through the process.\nFor further information related to cybersecurity in Schneider Electric\u2019s products, visit the company\u2019s cybersecurity support portal page: https://www.se.com/ww/en/work/support/cybersecurity/overview.jsp",
        "title": "For More Information"
      },
      {
        "category": "legal_disclaimer",
        "text": "THIS NOTIFICATION DOCUMENT, THE INFORMATION CONTAINED HEREIN, AND ANY MATERIALS LINKED FROM IT (COLLECTIVELY, THIS \u201cNOTIFICATION\u201d) ARE INTENDED TO HELP PROVIDE AN OVERVIEW OF THE IDENTIFIED SITUATION AND SUGGESTED MITIGATION ACTIONS, REMEDIATION, FIX, AND/OR GENERAL SECURITY RECOMMENDATIONS AND IS PROVIDED ON AN \u201cAS-IS\u201d BASIS WITHOUT WARRANTY OR GUARANTEE OF ANY KIND.  SCHNEIDER ELECTRIC DISCLAIMS ALL WARRANTIES RELATING TO THIS NOTIFICATION, EITHER EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. SCHNEIDER ELECTRIC MAKES NO WARRANTY THAT THE NOTIFICATION WILL RESOLVE THE IDENTIFIED SITUATION. IN NO EVENT SHALL SCHNEIDER ELECTRIC BE LIABLE FOR ANY DAMAGES OR LOSSES WHATSOEVER IN CONNECTION WITH THIS NOTIFICATION, INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF SCHNEIDER ELECTRIC HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. YOUR USE OF THIS NOTIFICATION IS AT YOUR OWN RISK, AND YOU ARE SOLELY LIABLE FOR ANY DAMAGES TO YOUR SYSTEMS OR ASSETS OR OTHER LOSSES THAT MAY RESULT FROM YOUR USE OF THIS NOTIFICATION. SCHNEIDER ELECTRIC RESERVES THE RIGHT TO UPDATE OR CHANGE THIS NOTIFICATION AT ANY TIME AND IN ITS SOLE DISCRETION",
        "title": "LEGAL DISCLAIMER"
      },
      {
        "category": "general",
        "text": "At Schneider, we believe access to energy and digital is a basic human right. We empower all to do more with less, ensuring Life Is On everywhere, for everyone, at every moment.\n\nWe provide energy and automation digital solutions for efficiency and sustainability. We combine world-leading energy technologies, real-time automation, software and services into integrated solutions for Homes, Buildings, Data Centers, Infrastructure and Industries.\n\nWe are committed to unleash the infinite possibilities of an open, global, innovative community that is passionate with our Meaningful Purpose, Inclusive and Empowered values.\n\nwww.se.com ",
        "title": "About Schneider Electric"
      },
      {
        "category": "summary",
        "text": "Schneider Electric is aware of multiple vulnerabilities in its PowerLogic ION7400, ION7650, \r\nION7700/73xx, ION83xx/84xx/85xx/8600, ION8650, ION8800, ION9000 and PM8000 products. \r\nThe PowerLogic metering products are revenue and power quality meters for utility and \r\nindustrial electrical network monitoring. \r\nFailure to apply the mitigations/remediations provided below may risk disclosure of user \r\ncredentials when using HTTP or Telnet protocol or cause a user to perform an unintended \r\naction on a target device when using HTTP, which could result in unintended device behavior.",
        "title": "Overview"
      },
      {
        "category": "summary",
        "text": "Customers should use appropriate methodologies when applying these upgrades to their devices. We strongly recommend evaluating the impact of these updates in a test and development environment prior to deployment. Contact Schneider Electric\u0027s Customer Care Center if you need assistance reverting to an older version of firmware.",
        "title": "Overview"
      }
    ],
    "publisher": {
      "category": "vendor",
      "contact_details": "cpcert@se.com",
      "name": "Schneider Electric CPCERT",
      "namespace": "https://www.se.com/ww/en/work/support/cybersecurity/security-notifications.jsp"
    },
    "references": [
      {
        "category": "self",
        "summary": "PowerLogic Power Metering Products - SEVD-2021-040-01 PDF Version",
        "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-040-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2021-040-01_PowerLogic_Power_Metering_Security_Notification.pdf"
      },
      {
        "category": "self",
        "summary": "PowerLogic Power Metering Products - SEVD-2021-040-01 CSAF Version",
        "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-040-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=sevd-2021-040-01.json"
      },
      {
        "category": "external",
        "summary": "Recommended Cybersecurity Best Practices",
        "url": "https://www.se.com/us/en/download/document/7EN52-0390/"
      }
    ],
    "title": "PowerLogic Power Metering Products",
    "tracking": {
      "current_release_date": "2021-02-08T00:00:00.000Z",
      "generator": {
        "date": "2021-02-08T00:00:00Z",
        "engine": {
          "name": "Schneider Electric CSAF Generator",
          "version": "1.2"
        }
      },
      "id": "SEVD-2021-040-01",
      "initial_release_date": "2021-02-08T00:00:00.000Z",
      "revision_history": [
        {
          "date": "2021-02-08T00:00:00.000Z",
          "number": "1.0.0",
          "summary": "Original Release"
        }
      ],
      "status": "final",
      "version": "1.0.0"
    }
  },
  "product_tree": {
    "branches": [
      {
        "branches": [
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "\u003c3.0.0",
                "product": {
                  "name": "Schneider Electric ION7400 All versions prior to V3.0.0",
                  "product_id": "1"
                }
              }
            ],
            "category": "product_name",
            "name": "ION7400"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "vers:all/*",
                "product": {
                  "name": "Schneider Electric ION7650 All versions",
                  "product_id": "2"
                }
              }
            ],
            "category": "product_name",
            "name": "ION7650"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "vers:all/*",
                "product": {
                  "name": "Schneider Electric ION7700/73xx All versions. Note: Only affected by CVE-2021-22702 as these products do not support HTTP web functionality.",
                  "product_id": "3"
                }
              }
            ],
            "category": "product_name",
            "name": "ION7700/73xx"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "vers:all/*",
                "product": {
                  "name": "Schneider Electric ION83xx/84xx/85xx/8600 All versions",
                  "product_id": "4"
                }
              }
            ],
            "category": "product_name",
            "name": "ION83xx/84xx/85xx/8600"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "\u003c=4.31.2",
                "product": {
                  "name": "Schneider Electric ION8650 V 4.31.2 and prior",
                  "product_id": "5"
                }
              }
            ],
            "category": "product_name",
            "name": "ION8650"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "vers:all/*",
                "product": {
                  "name": "Schneider Electric ION8800 All versions",
                  "product_id": "6"
                }
              }
            ],
            "category": "product_name",
            "name": "ION8800"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "\u003c3.0.0",
                "product": {
                  "name": "Schneider Electric ION9000 All versions prior to V3.0.0",
                  "product_id": "7"
                }
              }
            ],
            "category": "product_name",
            "name": "ION9000"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "\u003c3.0.0",
                "product": {
                  "name": "Schneider Electric PM8000 All versions prior to V3.0.0",
                  "product_id": "8"
                }
              }
            ],
            "category": "product_name",
            "name": "PM8000"
          },
          {
            "branches": [
              {
                "category": "product_version",
                "name": "3.0.0",
                "product": {
                  "name": "Schneider Electric PowerLogic ION7400 V3.0.0",
                  "product_id": "9"
                }
              }
            ],
            "category": "product_name",
            "name": "PowerLogic ION7400"
          },
          {
            "branches": [
              {
                "category": "product_version",
                "name": "4.40.1",
                "product": {
                  "name": "Schneider Electric PowerLogic ION8650 V4.40.1",
                  "product_id": "10"
                }
              }
            ],
            "category": "product_name",
            "name": "PowerLogic ION8650"
          },
          {
            "branches": [
              {
                "category": "product_version",
                "name": "3.0.0",
                "product": {
                  "name": "Schneider Electric PowerLogic ION9000 V3.0.0",
                  "product_id": "11"
                }
              }
            ],
            "category": "product_name",
            "name": "PowerLogic ION9000"
          },
          {
            "branches": [
              {
                "category": "product_version",
                "name": "3.0.0",
                "product": {
                  "name": "Schneider Electric PowerLogic PM8000 V3.0.0",
                  "product_id": "12"
                }
              }
            ],
            "category": "product_name",
            "name": "PowerLogic PM8000"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "\u003c2.1.0|\u003e2.2.1",
                "product": {
                  "name": "Schneider Electric ION7400 v2.1.0 to V2.2.1",
                  "product_id": "13"
                }
              }
            ],
            "category": "product_name",
            "name": "ION7400"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "\u003c2.1.0|\u003e2.2.1",
                "product": {
                  "name": "Schneider Electric PM8000 V2.1.0 to V2.2.1",
                  "product_id": "14"
                }
              }
            ],
            "category": "product_name",
            "name": "PM8000"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "\u003c2.1.0",
                "product": {
                  "name": "Schneider Electric ION7400 prior to V2.1.0",
                  "product_id": "15"
                }
              }
            ],
            "category": "product_name",
            "name": "ION7400"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "\u003c2.1.0",
                "product": {
                  "name": "Schneider Electric PM8000 prior to V2.1.0",
                  "product_id": "16"
                }
              }
            ],
            "category": "product_name",
            "name": "PM8000"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "\u003c4.20.1|\u003e4.31.2",
                "product": {
                  "name": "Schneider Electric ION8650 V4.20.1 to 4.31.2",
                  "product_id": "17"
                }
              }
            ],
            "category": "product_name",
            "name": "ION8650"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "\u003e=415",
                "product": {
                  "name": "Schneider Electric ION7650 V415 or later",
                  "product_id": "18"
                }
              }
            ],
            "category": "product_name",
            "name": "ION7650"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "\u003e= 362",
                "product": {
                  "name": "Schneider Electric ION8800 V362 or later",
                  "product_id": "19"
                }
              }
            ],
            "category": "product_name",
            "name": "ION8800"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "\u003c4.20.1",
                "product": {
                  "name": "Schneider Electric ION8650 prior to V4.20.1",
                  "product_id": "20"
                }
              }
            ],
            "category": "product_name",
            "name": "ION8650"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "\u003c415",
                "product": {
                  "name": "Schneider Electric ION7650 prior to V415",
                  "product_id": "21"
                }
              }
            ],
            "category": "product_name",
            "name": "ION7650"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "\u003c362",
                "product": {
                  "name": "Schneider Electric ION8800 prior to V362",
                  "product_id": "22"
                }
              }
            ],
            "category": "product_name",
            "name": "ION8800"
          }
        ],
        "category": "vendor",
        "name": "Schneider Electric"
      }
    ]
  },
  "vulnerabilities": [
    {
      "cve": "CVE-2021-22701",
      "cwe": {
        "id": "CWE-352",
        "name": "Cross-Site Request Forgery (CSRF)"
      },
      "notes": [
        {
          "category": "description",
          "text": "CWE-352: Cross-Site Request Forgery vulnerability exists that could cause a user to perform \r\nan unintended action on the target device when using the HTTP web interface.",
          "title": "CVE Description"
        }
      ],
      "product_status": {
        "fixed": [
          "9",
          "10",
          "11",
          "12"
        ],
        "known_affected": [
          "1",
          "2",
          "4",
          "5",
          "6",
          "7",
          "8"
        ]
      },
      "remediations": [
        {
          "category": "vendor_fix",
          "details": "V3.0.0 of the PowerLogic ION7400 firmware includes fixes\r\nfor these vulnerabilities by replacing Telnet functionality \r\nwith SSH. Additionally, HTTP web interface was removed \r\n(only HTTPS mode now supported). The version update \r\nfiles are available for download here:\r\nhttps://www.se.com/ww/en/download/document/ION7400_\r\nmeter_FW_v003.000.000/\r\nNote: There may be newer versions of the firmware \r\navailable for download, please check the ION7400 https://www.se.com/us/en/product-range-download/63502-powerlogic-ion7400-series/#/software-firmware-tab product \r\npage on se.com before upgrading.\r\nCustomers who do not wish to apply this remediation \r\nshould refer to the mitigations below.",
          "product_ids": [
            "1"
          ],
          "restart_required": {
            "category": "none"
          },
          "url": "https://www.se.com/ww/en/download/document/ION7400_meter_FW_v003.000.000/"
        },
        {
          "category": "vendor_fix",
          "details": "V4.40.1 of the PowerLogic ION8650 firmware includes fixes\r\nfor these vulnerabilities by replacing Telnet functionality \r\nwith SSH and making web pages read only. The version \r\nupdate files are available for download here: \r\nhttps://www.se.com/ww/en/download/document/ION8650_\r\nmeter_FW_V004.040.001/\r\nNote: There may be newer versions of the firmware \r\navailable for download, please check the ION8650 https://www.se.com/us/en/product-range-download/61053-powerlogic-ion8650-series/?selected-node-id=12144491661#/software-firmware-tab product \r\npage on se.com before upgrading.\r\nCustomers who do not wish to apply this remediation \r\nshould refer to the mitigations below.",
          "product_ids": [
            "5"
          ],
          "restart_required": {
            "category": "none"
          },
          "url": "https://www.se.com/ww/en/download/document/ION8650_meter_FW_V004.040.001/"
        },
        {
          "category": "vendor_fix",
          "details": "V3.0.0 of the PowerLogic ION9000 firmware includes fixes\r\nfor these vulnerabilities by replacing telnet functionality with \r\nSSH. Additionally, HTTP web interface was removed (only \r\nHTTPS mode now supported). The version update files are\r\navailable for download here:\r\nhttps://www.se.com/ww/en/download/document/ION9000_\r\nmeter_FW_v003.000.000/\r\nNote: There may be newer versions of the firmware \r\navailable for download, please check the ION9000 https://www.se.com/us/en/product-range-download/64241-powerlogic-ion9000-series/#/software-firmware-tab product \r\npage on se.com before upgrading.\r\nCustomers who do not wish to apply this remediation \r\nshould refer to the mitigations below.",
          "product_ids": [
            "7"
          ],
          "restart_required": {
            "category": "none"
          },
          "url": "https://www.se.com/ww/en/download/document/ION9000_meter_FW_v003.000.000/"
        },
        {
          "category": "vendor_fix",
          "details": "V3.0.0 of the PowerLogic PM8000 firmware includes fixes\r\nfor these vulnerabilities by replacing telnet functionality with \r\nSSH. Additionally, HTTP web interface was removed (only \r\nHTTPS mode now supported). The version update files are\r\navailable for download here:\r\nhttps://www.se.com/ww/en/download/document/PM8000_m\r\neter_FW_v003.000.000/ \r\nNote: There may be newer versions of the firmware \r\navailable for download, please check the ION8000 https://www.se.com/us/en/product-range-download/62252-powerlogic-pm8000-series/#/software-firmware-tab product \r\npage on se.com before upgrading.\r\nCustomers who do not wish to apply this remediation \r\nshould refer to the mitigations below.",
          "product_ids": [
            "8"
          ],
          "restart_required": {
            "category": "none"
          },
          "url": "https://www.se.com/ww/en/download/document/PM8000_meter_FW_v003.000.000/"
        },
        {
          "category": "mitigation",
          "details": "A remediation does not exist for these products, please \r\nrefer to the Mitigations section below for information on how \r\nto reduce the risk of exploit. ",
          "product_ids": [
            "2",
            "4",
            "6"
          ],
          "restart_required": {
            "category": "none"
          }
        },
        {
          "category": "mitigation",
          "details": "Customers should immediately apply the following mitigations \r\nto reduce the risk of exploit:\r\n\u2022 Disable Telnet functionality\r\n\u2022 To mitigate plain text HTTP, ensure HTTPS is enabled\r\n\u2022 To mitigate Cross-Site request forgery, disable HTTP\r\nand HTTPS web functionality",
          "product_ids": [
            "7"
          ],
          "restart_required": {
            "category": "none"
          }
        },
        {
          "category": "mitigation",
          "details": "Customers should immediately apply the following mitigations \r\nto reduce the risk of exploit:\r\n\u2022 Disable Telnet functionality\r\n\u2022 To mitigate plain text HTTP, ensure HTTPS is enabled\r\n\u2022 To mitigate Cross-Site request forgery, disable HTTP\r\nand HTTPS web functionality",
          "product_ids": [
            "7",
            "13",
            "14"
          ],
          "restart_required": {
            "category": "none"
          }
        },
        {
          "category": "mitigation",
          "details": "Customers should immediately apply the following mitigations \r\nto reduce the risk of exploit:\r\n\u2022 Disable Telnet functionality\r\n\u2022 Disable HTTP functionality",
          "product_ids": [
            "15",
            "16"
          ],
          "restart_required": {
            "category": "none"
          }
        },
        {
          "category": "mitigation",
          "details": "Customers should immediately apply the following mitigations \r\nto reduce the risk of exploit:\r\n\u2022 Disable Telnet functionality\r\n\u2022 Disable HTTP web functionality",
          "product_ids": [
            "17",
            "18",
            "19"
          ],
          "restart_required": {
            "category": "none"
          }
        },
        {
          "category": "mitigation",
          "details": "Customers should immediately apply the following mitigations \r\nto reduce the risk of exploit:\r\n\u2022 Disable HTTP web functionality\r\nA mitigation does not exist for Telnet access. Please upgrade \r\nto a newer firmware version and apply the appropriate \r\nmitigation.",
          "product_ids": [
            "20",
            "21",
            "22"
          ],
          "restart_required": {
            "category": "none"
          }
        },
        {
          "category": "mitigation",
          "details": "These products are no longer within a support period. \r\nCustomers should immediately apply the following mitigations \r\nto reduce the risk of exploit:\r\n\u2022 Disable HTTP web functionality\r\nA mitigation does not exist for Telnet access. Customers \r\nshould also consider upgrading to the latest product offering \r\nPowerLogic ION8650 https://www.se.com/ww/en/product-range/61053-powerlogic-ion8650/  to resolve these vulnerabilities. \r\n",
          "product_ids": [
            "4"
          ],
          "restart_required": {
            "category": "none"
          },
          "url": "https://www.se.com/ww/en/product-range/61053-powerlogic-ion8650/"
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 6.1,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:R/S:U/C:N/I:H/A:H",
            "version": "3.0"
          },
          "products": [
            "1",
            "2",
            "4",
            "5",
            "6",
            "7",
            "8"
          ]
        }
      ],
      "title": "CVE-2021-22701"
    },
    {
      "cve": "CVE-2021-22702",
      "cwe": {
        "id": "CWE-319",
        "name": "Cleartext Transmission of Sensitive Information"
      },
      "notes": [
        {
          "category": "description",
          "text": "CWE-319: Cleartext transmission of sensitive information vulnerability exists that could \r\ncause disclosure of user credentials when a malicious actor intercepts Telnet network traffic \r\nbetween a user and the device.",
          "title": "CVE Description"
        }
      ],
      "product_status": {
        "fixed": [
          "9",
          "10",
          "11",
          "12"
        ],
        "known_affected": [
          "1",
          "2",
          "3",
          "4",
          "5",
          "6",
          "7",
          "8"
        ]
      },
      "remediations": [
        {
          "category": "vendor_fix",
          "details": "V3.0.0 of the PowerLogic ION7400 firmware includes fixes\r\nfor these vulnerabilities by replacing Telnet functionality \r\nwith SSH. Additionally, HTTP web interface was removed \r\n(only HTTPS mode now supported). The version update \r\nfiles are available for download here:\r\nhttps://www.se.com/ww/en/download/document/ION7400_\r\nmeter_FW_v003.000.000/\r\nNote: There may be newer versions of the firmware \r\navailable for download, please check the ION7400 https://www.se.com/us/en/product-range-download/63502-powerlogic-ion7400-series/#/software-firmware-tab product \r\npage on se.com before upgrading.\r\nCustomers who do not wish to apply this remediation \r\nshould refer to the mitigations below.",
          "product_ids": [
            "1"
          ],
          "restart_required": {
            "category": "none"
          },
          "url": "https://www.se.com/ww/en/download/document/ION7400_meter_FW_v003.000.000/"
        },
        {
          "category": "vendor_fix",
          "details": "V4.40.1 of the PowerLogic ION8650 firmware includes fixes\r\nfor these vulnerabilities by replacing Telnet functionality \r\nwith SSH and making web pages read only. The version \r\nupdate files are available for download here: \r\nhttps://www.se.com/ww/en/download/document/ION8650_\r\nmeter_FW_V004.040.001/\r\nNote: There may be newer versions of the firmware \r\navailable for download, please check the ION8650 https://www.se.com/us/en/product-range-download/61053-powerlogic-ion8650-series/?selected-node-id=12144491661#/software-firmware-tab product \r\npage on se.com before upgrading.\r\nCustomers who do not wish to apply this remediation \r\nshould refer to the mitigations below.",
          "product_ids": [
            "5"
          ],
          "restart_required": {
            "category": "none"
          },
          "url": "https://www.se.com/ww/en/download/document/ION8650_meter_FW_V004.040.001/"
        },
        {
          "category": "vendor_fix",
          "details": "V3.0.0 of the PowerLogic ION9000 firmware includes fixes\r\nfor these vulnerabilities by replacing telnet functionality with \r\nSSH. Additionally, HTTP web interface was removed (only \r\nHTTPS mode now supported). The version update files are\r\navailable for download here:\r\nhttps://www.se.com/ww/en/download/document/ION9000_\r\nmeter_FW_v003.000.000/\r\nNote: There may be newer versions of the firmware \r\navailable for download, please check the ION9000 https://www.se.com/us/en/product-range-download/64241-powerlogic-ion9000-series/#/software-firmware-tab product \r\npage on se.com before upgrading.\r\nCustomers who do not wish to apply this remediation \r\nshould refer to the mitigations below.",
          "product_ids": [
            "7"
          ],
          "restart_required": {
            "category": "none"
          },
          "url": "https://www.se.com/ww/en/download/document/ION9000_meter_FW_v003.000.000/"
        },
        {
          "category": "vendor_fix",
          "details": "V3.0.0 of the PowerLogic PM8000 firmware includes fixes\r\nfor these vulnerabilities by replacing telnet functionality with \r\nSSH. Additionally, HTTP web interface was removed (only \r\nHTTPS mode now supported). The version update files are\r\navailable for download here:\r\nhttps://www.se.com/ww/en/download/document/PM8000_m\r\neter_FW_v003.000.000/ \r\nNote: There may be newer versions of the firmware \r\navailable for download, please check the ION8000 https://www.se.com/us/en/product-range-download/62252-powerlogic-pm8000-series/#/software-firmware-tab product \r\npage on se.com before upgrading.\r\nCustomers who do not wish to apply this remediation \r\nshould refer to the mitigations below.",
          "product_ids": [
            "8"
          ],
          "restart_required": {
            "category": "none"
          },
          "url": "https://www.se.com/ww/en/download/document/PM8000_meter_FW_v003.000.000/"
        },
        {
          "category": "mitigation",
          "details": "A remediation does not exist for these products, please \r\nrefer to the Mitigations section below for information on how \r\nto reduce the risk of exploit. ",
          "product_ids": [
            "2",
            "3",
            "4",
            "6"
          ],
          "restart_required": {
            "category": "none"
          }
        },
        {
          "category": "mitigation",
          "details": "Customers should immediately apply the following mitigations \r\nto reduce the risk of exploit:\r\n\u2022 Disable Telnet functionality\r\n\u2022 To mitigate plain text HTTP, ensure HTTPS is enabled\r\n\u2022 To mitigate Cross-Site request forgery, disable HTTP\r\nand HTTPS web functionality",
          "product_ids": [
            "7"
          ],
          "restart_required": {
            "category": "none"
          }
        },
        {
          "category": "mitigation",
          "details": "Customers should immediately apply the following mitigations \r\nto reduce the risk of exploit:\r\n\u2022 Disable Telnet functionality\r\n\u2022 To mitigate plain text HTTP, ensure HTTPS is enabled\r\n\u2022 To mitigate Cross-Site request forgery, disable HTTP\r\nand HTTPS web functionality",
          "product_ids": [
            "7",
            "13",
            "14"
          ],
          "restart_required": {
            "category": "none"
          }
        },
        {
          "category": "mitigation",
          "details": "Customers should immediately apply the following mitigations \r\nto reduce the risk of exploit:\r\n\u2022 Disable Telnet functionality\r\n\u2022 Disable HTTP functionality",
          "product_ids": [
            "15",
            "16"
          ],
          "restart_required": {
            "category": "none"
          }
        },
        {
          "category": "mitigation",
          "details": "Customers should immediately apply the following mitigations \r\nto reduce the risk of exploit:\r\n\u2022 Disable Telnet functionality\r\n\u2022 Disable HTTP web functionality",
          "product_ids": [
            "17",
            "18",
            "19"
          ],
          "restart_required": {
            "category": "none"
          }
        },
        {
          "category": "mitigation",
          "details": "Customers should immediately apply the following mitigations \r\nto reduce the risk of exploit:\r\n\u2022 Disable HTTP web functionality\r\nA mitigation does not exist for Telnet access. Please upgrade \r\nto a newer firmware version and apply the appropriate \r\nmitigation.",
          "product_ids": [
            "20",
            "21",
            "22"
          ],
          "restart_required": {
            "category": "none"
          }
        },
        {
          "category": "mitigation",
          "details": "These products are no longer within a support period. \r\nCustomers should immediately apply the following mitigations \r\nto reduce the risk of exploit:\r\n\u2022 Disable HTTP web functionality\r\nA mitigation does not exist for Telnet access. Customers \r\nshould also consider upgrading to the latest product offering \r\nPowerLogic ION8650 https://www.se.com/ww/en/product-range/61053-powerlogic-ion8650/  to resolve these vulnerabilities. \r\n",
          "product_ids": [
            "4"
          ],
          "restart_required": {
            "category": "none"
          },
          "url": "https://www.se.com/ww/en/product-range/61053-powerlogic-ion8650/"
        },
        {
          "category": "mitigation",
          "details": "These products are no longer within a support period.\r\nA mitigation does not exist for Telnet access. Customers \r\nshould consider upgrading to the latest product offering \r\nPowerLogic ION9000 https://www.se.com/ww/en/product-range/64241-powerlogic%E2%84%A2-ion9000/ , PowerLogic PM8000 https://www.se.com/ww/en/product-range/62252-powerlogic-pm8000-series/ , or PowerLogic \r\nION7400 https://www.se.com/ww/en/product-range/63502-powerlogic-ion7400/  to resolve these vulnerabilities.",
          "product_ids": [
            "3"
          ],
          "restart_required": {
            "category": "none"
          },
          "url": "https://www.se.com/ww/en/product-range/64241-powerlogic-ion9000/#products,https://www.se.com/ww/en/product-range/62252-powerlogic-pm8000-series/,https://www.se.com/ww/en/product-range/63502-powerlogic-ion7400/"
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.0"
          },
          "products": [
            "1",
            "2",
            "3",
            "4",
            "5",
            "6",
            "7",
            "8"
          ]
        }
      ],
      "title": "CVE-2021-22702"
    },
    {
      "cve": "CVE-2021-22703",
      "cwe": {
        "id": "CWE-319",
        "name": "Cleartext Transmission of Sensitive Information"
      },
      "notes": [
        {
          "category": "description",
          "text": "CWE-319: Cleartext transmission of sensitive information vulnerability exists that could \r\ncause disclosure of user credentials when a malicious actor intercepts HTTP network traffic \r\nbetween a user and the device.",
          "title": "CVE Description"
        }
      ],
      "product_status": {
        "fixed": [
          "9",
          "10",
          "11",
          "12"
        ],
        "known_affected": [
          "1",
          "2",
          "4",
          "5",
          "6",
          "7",
          "8"
        ]
      },
      "remediations": [
        {
          "category": "vendor_fix",
          "details": "V3.0.0 of the PowerLogic ION7400 firmware includes fixes\r\nfor these vulnerabilities by replacing Telnet functionality \r\nwith SSH. Additionally, HTTP web interface was removed \r\n(only HTTPS mode now supported). The version update \r\nfiles are available for download here:\r\nhttps://www.se.com/ww/en/download/document/ION7400_\r\nmeter_FW_v003.000.000/\r\nNote: There may be newer versions of the firmware \r\navailable for download, please check the ION7400 https://www.se.com/us/en/product-range-download/63502-powerlogic-ion7400-series/#/software-firmware-tab product \r\npage on se.com before upgrading.\r\nCustomers who do not wish to apply this remediation \r\nshould refer to the mitigations below.",
          "product_ids": [
            "1"
          ],
          "restart_required": {
            "category": "none"
          },
          "url": "https://www.se.com/ww/en/download/document/ION7400_meter_FW_v003.000.000/"
        },
        {
          "category": "vendor_fix",
          "details": "V4.40.1 of the PowerLogic ION8650 firmware includes fixes\r\nfor these vulnerabilities by replacing Telnet functionality \r\nwith SSH and making web pages read only. The version \r\nupdate files are available for download here: \r\nhttps://www.se.com/ww/en/download/document/ION8650_\r\nmeter_FW_V004.040.001/\r\nNote: There may be newer versions of the firmware \r\navailable for download, please check the ION8650 https://www.se.com/us/en/product-range-download/61053-powerlogic-ion8650-series/?selected-node-id=12144491661#/software-firmware-tab product \r\npage on se.com before upgrading.\r\nCustomers who do not wish to apply this remediation \r\nshould refer to the mitigations below.",
          "product_ids": [
            "5"
          ],
          "restart_required": {
            "category": "none"
          },
          "url": "https://www.se.com/ww/en/download/document/ION8650_meter_FW_V004.040.001/"
        },
        {
          "category": "vendor_fix",
          "details": "V3.0.0 of the PowerLogic ION9000 firmware includes fixes\r\nfor these vulnerabilities by replacing telnet functionality with \r\nSSH. Additionally, HTTP web interface was removed (only \r\nHTTPS mode now supported). The version update files are\r\navailable for download here:\r\nhttps://www.se.com/ww/en/download/document/ION9000_\r\nmeter_FW_v003.000.000/\r\nNote: There may be newer versions of the firmware \r\navailable for download, please check the ION9000 https://www.se.com/us/en/product-range-download/64241-powerlogic-ion9000-series/#/software-firmware-tab product \r\npage on se.com before upgrading.\r\nCustomers who do not wish to apply this remediation \r\nshould refer to the mitigations below.",
          "product_ids": [
            "7"
          ],
          "restart_required": {
            "category": "none"
          },
          "url": "https://www.se.com/ww/en/download/document/ION9000_meter_FW_v003.000.000/"
        },
        {
          "category": "vendor_fix",
          "details": "V3.0.0 of the PowerLogic PM8000 firmware includes fixes\r\nfor these vulnerabilities by replacing telnet functionality with \r\nSSH. Additionally, HTTP web interface was removed (only \r\nHTTPS mode now supported). The version update files are\r\navailable for download here:\r\nhttps://www.se.com/ww/en/download/document/PM8000_m\r\neter_FW_v003.000.000/ \r\nNote: There may be newer versions of the firmware \r\navailable for download, please check the ION8000 https://www.se.com/us/en/product-range-download/62252-powerlogic-pm8000-series/#/software-firmware-tab product \r\npage on se.com before upgrading.\r\nCustomers who do not wish to apply this remediation \r\nshould refer to the mitigations below.",
          "product_ids": [
            "8"
          ],
          "restart_required": {
            "category": "none"
          },
          "url": "https://www.se.com/ww/en/download/document/PM8000_meter_FW_v003.000.000/"
        },
        {
          "category": "mitigation",
          "details": "A remediation does not exist for these products, please \r\nrefer to the Mitigations section below for information on how \r\nto reduce the risk of exploit. ",
          "product_ids": [
            "2",
            "4",
            "6"
          ],
          "restart_required": {
            "category": "none"
          }
        },
        {
          "category": "mitigation",
          "details": "Customers should immediately apply the following mitigations \r\nto reduce the risk of exploit:\r\n\u2022 Disable Telnet functionality\r\n\u2022 To mitigate plain text HTTP, ensure HTTPS is enabled\r\n\u2022 To mitigate Cross-Site request forgery, disable HTTP\r\nand HTTPS web functionality",
          "product_ids": [
            "7"
          ],
          "restart_required": {
            "category": "none"
          }
        },
        {
          "category": "mitigation",
          "details": "Customers should immediately apply the following mitigations \r\nto reduce the risk of exploit:\r\n\u2022 Disable Telnet functionality\r\n\u2022 To mitigate plain text HTTP, ensure HTTPS is enabled\r\n\u2022 To mitigate Cross-Site request forgery, disable HTTP\r\nand HTTPS web functionality",
          "product_ids": [
            "7",
            "13",
            "14"
          ],
          "restart_required": {
            "category": "none"
          }
        },
        {
          "category": "mitigation",
          "details": "Customers should immediately apply the following mitigations \r\nto reduce the risk of exploit:\r\n\u2022 Disable Telnet functionality\r\n\u2022 Disable HTTP functionality",
          "product_ids": [
            "15",
            "16"
          ],
          "restart_required": {
            "category": "none"
          }
        },
        {
          "category": "mitigation",
          "details": "Customers should immediately apply the following mitigations \r\nto reduce the risk of exploit:\r\n\u2022 Disable Telnet functionality\r\n\u2022 Disable HTTP web functionality",
          "product_ids": [
            "17",
            "18",
            "19"
          ],
          "restart_required": {
            "category": "none"
          }
        },
        {
          "category": "mitigation",
          "details": "Customers should immediately apply the following mitigations \r\nto reduce the risk of exploit:\r\n\u2022 Disable HTTP web functionality\r\nA mitigation does not exist for Telnet access. Please upgrade \r\nto a newer firmware version and apply the appropriate \r\nmitigation.",
          "product_ids": [
            "20",
            "21",
            "22"
          ],
          "restart_required": {
            "category": "none"
          }
        },
        {
          "category": "mitigation",
          "details": "These products are no longer within a support period. \r\nCustomers should immediately apply the following mitigations \r\nto reduce the risk of exploit:\r\n\u2022 Disable HTTP web functionality\r\nA mitigation does not exist for Telnet access. Customers \r\nshould also consider upgrading to the latest product offering \r\nPowerLogic ION8650 https://www.se.com/ww/en/product-range/61053-powerlogic-ion8650/  to resolve these vulnerabilities. \r\n",
          "product_ids": [
            "4"
          ],
          "restart_required": {
            "category": "none"
          },
          "url": "https://www.se.com/ww/en/product-range/61053-powerlogic-ion8650/"
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.0"
          },
          "products": [
            "1",
            "2",
            "4",
            "5",
            "6",
            "7",
            "8"
          ]
        }
      ],
      "title": "CVE-2021-22703"
    }
  ]
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.


Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…