SSA-390352
Vulnerability from csaf_siemens - Published: 2026-10-13 00:00 - Updated: 2026-10-13 00:00Affected applications do not properly validate filenames received from remote servers during ticket downloads. This could allow an attacker who can manipulate the ticket response to write arbitrary files outside the intended download directory and, when overwriting is enabled, replace existing files accessible to the application.
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
.NET Client Library for SIMATIC S7 Webserver API < V3.3.61
Siemens / .NET Client Library for SIMATIC S7 Webserver API
|
vers:intdot/<3.3.61 |
Vendor Fix
fix
|
Affected applications do not properly redact PLC restore passwords from HTTP error exception messages. This could allow an attacker with access to logs or other diagnostic output to obtain the plaintext restore password and potentially perform unauthorized operations on the PLC.
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
.NET Client Library for SIMATIC S7 Webserver API < V3.3.62
Siemens / .NET Client Library for SIMATIC S7 Webserver API
|
vers:intdot/<3.3.62 |
Vendor Fix
fix
|
{
"document": {
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Disclosure is not limited. (TLPv2: TLP:CLEAR)",
"tlp": {
"label": "WHITE"
}
},
"lang": "en",
"notes": [
{
"category": "summary",
"text": ".NET Client Library for SIMATIC S7 Webserver API contains multiple vulnerabilities that could allow an attacker to obtain sensitive information or write arbitrary files outside the intended download directory.\n\nSiemens has released a new version for .NET Client Library for SIMATIC S7 Webserver API and recommends to update to the latest version.",
"title": "Summary"
},
{
"category": "general",
"text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity",
"title": "General Recommendations"
},
{
"category": "general",
"text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories",
"title": "Additional Resources"
},
{
"category": "legal_disclaimer",
"text": "The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use.",
"title": "Terms of Use"
}
],
"publisher": {
"category": "vendor",
"contact_details": "productcert@siemens.com",
"name": "Siemens ProductCERT",
"namespace": "https://www.siemens.com"
},
"references": [
{
"category": "self",
"summary": "SSA-390352: Multiple Vulnerabilities in .NET Client Library for SIMATIC S7 Webserver API - HTML Version",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-390352.html"
},
{
"category": "self",
"summary": "SSA-390352: Multiple Vulnerabilities in .NET Client Library for SIMATIC S7 Webserver API - CSAF Version",
"url": "https://cert-portal.siemens.com/productcert/csaf/ssa-390352.json"
}
],
"title": "SSA-390352: Multiple Vulnerabilities in .NET Client Library for SIMATIC S7 Webserver API",
"tracking": {
"current_release_date": "2026-10-13T00:00:00.000Z",
"generator": {
"engine": {
"name": "Siemens ProductCERT CSAF Generator",
"version": "1"
}
},
"id": "SSA-390352",
"initial_release_date": "2026-10-13T00:00:00.000Z",
"revision_history": [
{
"date": "2026-10-13T00:00:00.000Z",
"legacy_version": "1.0",
"number": "1",
"summary": "Publication Date"
}
],
"status": "interim",
"version": "1"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c3.3.61",
"product": {
"name": ".NET Client Library for SIMATIC S7 Webserver API \u003c V3.3.61",
"product_id": "1"
}
},
{
"category": "product_version_range",
"name": "vers:intdot/\u003c3.3.62",
"product": {
"name": ".NET Client Library for SIMATIC S7 Webserver API \u003c V3.3.62",
"product_id": "2"
}
}
],
"category": "product_name",
"name": ".NET Client Library for SIMATIC S7 Webserver API"
}
],
"category": "vendor",
"name": "Siemens"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2026-85114",
"cwe": {
"id": "CWE-22",
"name": "Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)"
},
"notes": [
{
"category": "description",
"text": "Affected applications do not properly validate filenames received from remote servers during ticket downloads.\r\n\r\nThis could allow an attacker who can manipulate the ticket response to write arbitrary files outside the intended download directory and, when overwriting is enabled, replace existing files accessible to the application.",
"title": "CVE Description"
}
],
"product_status": {
"known_affected": [
"1"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V3.3.61 or later version",
"product_ids": [
"1"
],
"url": "https://github.com/siemens/simatic-s7-webserver-api/releases/tag/v3.3.61"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N",
"version": "3.1"
},
"products": [
"1"
]
}
],
"title": "CVE-2026-85114"
},
{
"cve": "CVE-2026-85115",
"cwe": {
"id": "CWE-209",
"name": "Generation of Error Message Containing Sensitive Information"
},
"notes": [
{
"category": "description",
"text": "Affected applications do not properly redact PLC restore passwords from HTTP error exception messages.\r\n\r\nThis could allow an attacker with access to logs or other diagnostic output to obtain the plaintext restore password and potentially perform unauthorized operations on the PLC.",
"title": "CVE Description"
}
],
"product_status": {
"known_affected": [
"2"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V3.3.62 or later version",
"product_ids": [
"2"
],
"url": "https://github.com/siemens/simatic-s7-webserver-api/releases/tag/v3.3.62"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 5.5,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"products": [
"2"
]
}
],
"title": "CVE-2026-85115"
}
]
}
Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline
Sightings and recorded dates, grouped by day · UTC
Loading timeline…
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
Related by attack behaviour
Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.