SSA-506569
Vulnerability from csaf_siemens - Published: 2022-11-08 00:00 - Updated: 2023-02-14 00:00Summary
SSA-506569: Multiple Vulnerabilities in SCALANCE W1750D
Notes
Summary
The SCALANCE W1750D device contains multiple vulnerabilities that could allow an attacker to inject commands or exploit buffer overflow vulnerabilities which could lead to denial of service, unauthenticated remote code execution or stored XSS.
Siemens has released updates for the affected products and recommends to update to the latest versions.
General Recommendations
As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download:
https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.
Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity
Additional Resources
For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories
Terms of Use
Siemens Security Advisories are subject to the terms and conditions contained in Siemens' underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter "License Terms"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens' Global Website (https://www.siemens.com/terms_of_use, hereinafter "Terms of Use"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.
{
"document": {
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Disclosure is not limited. (TLPv2: TLP:CLEAR)",
"tlp": {
"label": "WHITE"
}
},
"notes": [
{
"category": "summary",
"text": "The SCALANCE W1750D device contains multiple vulnerabilities that could allow an attacker to inject commands or exploit buffer overflow vulnerabilities which could lead to denial of service, unauthenticated remote code execution or stored XSS.\n\nSiemens has released updates for the affected products and recommends to update to the latest versions.",
"title": "Summary"
},
{
"category": "general",
"text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity",
"title": "General Recommendations"
},
{
"category": "general",
"text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories",
"title": "Additional Resources"
},
{
"category": "legal_disclaimer",
"text": "Siemens Security Advisories are subject to the terms and conditions contained in Siemens\u0027 underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter \"License Terms\"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens\u0027 Global Website (https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.",
"title": "Terms of Use"
}
],
"publisher": {
"category": "vendor",
"contact_details": "productcert@siemens.com",
"name": "Siemens ProductCERT",
"namespace": "https://www.siemens.com"
},
"references": [
{
"category": "self",
"summary": "SSA-506569: Multiple Vulnerabilities in SCALANCE W1750D - PDF Version",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-506569.pdf"
},
{
"category": "self",
"summary": "SSA-506569: Multiple Vulnerabilities in SCALANCE W1750D - TXT Version",
"url": "https://cert-portal.siemens.com/productcert/txt/ssa-506569.txt"
},
{
"category": "self",
"summary": "SSA-506569: Multiple Vulnerabilities in SCALANCE W1750D - CSAF Version",
"url": "https://cert-portal.siemens.com/productcert/csaf/ssa-506569.json"
}
],
"title": "SSA-506569: Multiple Vulnerabilities in SCALANCE W1750D",
"tracking": {
"current_release_date": "2023-02-14T00:00:00Z",
"generator": {
"engine": {
"name": "Siemens ProductCERT CSAF Generator",
"version": "1"
}
},
"id": "SSA-506569",
"initial_release_date": "2022-11-08T00:00:00Z",
"revision_history": [
{
"date": "2022-11-08T00:00:00Z",
"legacy_version": "1.0",
"number": "1",
"summary": "Publication Date"
},
{
"date": "2023-02-14T00:00:00Z",
"legacy_version": "1.1",
"number": "2",
"summary": "Added fix for SCALANCE W1750D"
}
],
"status": "final",
"version": "2"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c V8.7.1.11",
"product": {
"name": "SCALANCE W1750D (JP) (6GK5750-2HX01-1AD0)",
"product_id": "1",
"product_identification_helper": {
"model_numbers": [
"6GK5750-2HX01-1AD0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W1750D (JP) (6GK5750-2HX01-1AD0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c V8.7.1.11",
"product": {
"name": "SCALANCE W1750D (ROW) (6GK5750-2HX01-1AA0)",
"product_id": "2",
"product_identification_helper": {
"model_numbers": [
"6GK5750-2HX01-1AA0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W1750D (ROW) (6GK5750-2HX01-1AA0)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c V8.7.1.11",
"product": {
"name": "SCALANCE W1750D (USA) (6GK5750-2HX01-1AB0)",
"product_id": "3",
"product_identification_helper": {
"model_numbers": [
"6GK5750-2HX01-1AB0"
]
}
}
}
],
"category": "product_name",
"name": "SCALANCE W1750D (USA) (6GK5750-2HX01-1AB0)"
}
],
"category": "vendor",
"name": "Siemens"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2002-20001",
"cwe": {
"id": "CWE-400",
"name": "Uncontrolled Resource Consumption"
},
"notes": [
{
"category": "summary",
"text": "The Diffie-Hellman Key Agreement Protocol allows remote attackers (from the client side) to send arbitrary numbers that are actually not public keys, and trigger expensive server-side DHE modular-exponentiation calculations, aka a D(HE)ater attack. The client needs very little CPU resources and network bandwidth. The attack may be more disruptive in cases where a client can require a server to select its largest supported key size. The basic attack scenario is that the client must claim that it can only communicate with DHE, and the server must be configured to allow DHE. (ATLWL-266)",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"1",
"2",
"3"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V8.7.1.11 or later version",
"product_ids": [
"1",
"2",
"3"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109816886/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:T/RC:C",
"version": "3.1"
},
"products": [
"1",
"2",
"3"
]
}
],
"title": "CVE-2002-20001"
},
{
"cve": "CVE-2022-37885",
"cwe": {
"id": "CWE-120",
"name": "Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)"
},
"notes": [
{
"category": "summary",
"text": "A buffer overflow vulnerability in an underlying service could lead to unauthenticated remote code execution by sending specially crafted packets destined to the PAPI UDP port (8211). (ATLWL-253)",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"1",
"2",
"3"
]
},
"remediations": [
{
"category": "mitigation",
"details": "CVE-2022-37885, CVE-2022-37886, CVE-2022-37887, CVE-2022-37888, CVE-2022-37889: Enable CPSec via the cluster-security command",
"product_ids": [
"1",
"2",
"3"
]
},
{
"category": "vendor_fix",
"details": "Update to V8.7.1.11 or later version",
"product_ids": [
"1",
"2",
"3"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109816886/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:T/RC:C",
"version": "3.1"
},
"products": [
"1",
"2",
"3"
]
}
],
"title": "CVE-2022-37885"
},
{
"cve": "CVE-2022-37886",
"cwe": {
"id": "CWE-120",
"name": "Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)"
},
"notes": [
{
"category": "summary",
"text": "A buffer overflow vulnerability in an underlying service could lead to unauthenticated remote code execution by sending specially crafted packets destined to the PAPI UDP port (8211). (ATLWL-254)",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"1",
"2",
"3"
]
},
"remediations": [
{
"category": "mitigation",
"details": "CVE-2022-37885, CVE-2022-37886, CVE-2022-37887, CVE-2022-37888, CVE-2022-37889: Enable CPSec via the cluster-security command",
"product_ids": [
"1",
"2",
"3"
]
},
{
"category": "vendor_fix",
"details": "Update to V8.7.1.11 or later version",
"product_ids": [
"1",
"2",
"3"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109816886/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:T/RC:C",
"version": "3.1"
},
"products": [
"1",
"2",
"3"
]
}
],
"title": "CVE-2022-37886"
},
{
"cve": "CVE-2022-37887",
"cwe": {
"id": "CWE-120",
"name": "Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)"
},
"notes": [
{
"category": "summary",
"text": "A buffer overflow vulnerability in an underlying service could lead to unauthenticated remote code execution by sending specially crafted packets destined to the PAPI UDP port (8211). (ATLWL-299)",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"1",
"2",
"3"
]
},
"remediations": [
{
"category": "mitigation",
"details": "CVE-2022-37885, CVE-2022-37886, CVE-2022-37887, CVE-2022-37888, CVE-2022-37889: Enable CPSec via the cluster-security command",
"product_ids": [
"1",
"2",
"3"
]
},
{
"category": "vendor_fix",
"details": "Update to V8.7.1.11 or later version",
"product_ids": [
"1",
"2",
"3"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109816886/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:T/RC:C",
"version": "3.1"
},
"products": [
"1",
"2",
"3"
]
}
],
"title": "CVE-2022-37887"
},
{
"cve": "CVE-2022-37888",
"cwe": {
"id": "CWE-120",
"name": "Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)"
},
"notes": [
{
"category": "summary",
"text": "A buffer overflow vulnerability in an underlying service could lead to unauthenticated remote code execution by sending specially crafted packets destined to the PAPI UDP port (8211). (ATLWL-300)",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"1",
"2",
"3"
]
},
"remediations": [
{
"category": "mitigation",
"details": "CVE-2022-37885, CVE-2022-37886, CVE-2022-37887, CVE-2022-37888, CVE-2022-37889: Enable CPSec via the cluster-security command",
"product_ids": [
"1",
"2",
"3"
]
},
{
"category": "vendor_fix",
"details": "Update to V8.7.1.11 or later version",
"product_ids": [
"1",
"2",
"3"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109816886/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:T/RC:C",
"version": "3.1"
},
"products": [
"1",
"2",
"3"
]
}
],
"title": "CVE-2022-37888"
},
{
"cve": "CVE-2022-37889",
"cwe": {
"id": "CWE-120",
"name": "Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)"
},
"notes": [
{
"category": "summary",
"text": "A buffer overflow vulnerability in an underlying service could lead to unauthenticated remote code execution by sending specially crafted packets destined to the PAPI UDP port (8211). (ATLWL-302)",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"1",
"2",
"3"
]
},
"remediations": [
{
"category": "mitigation",
"details": "CVE-2022-37885, CVE-2022-37886, CVE-2022-37887, CVE-2022-37888, CVE-2022-37889: Enable CPSec via the cluster-security command",
"product_ids": [
"1",
"2",
"3"
]
},
{
"category": "vendor_fix",
"details": "Update to V8.7.1.11 or later version",
"product_ids": [
"1",
"2",
"3"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109816886/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:T/RC:C",
"version": "3.1"
},
"products": [
"1",
"2",
"3"
]
}
],
"title": "CVE-2022-37889"
},
{
"cve": "CVE-2022-37890",
"cwe": {
"id": "CWE-120",
"name": "Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)"
},
"notes": [
{
"category": "summary",
"text": "An unauthenticated buffer overflow vulnerability exists within the web management interface. Successful exploitation results in the execution of arbitrary commands on the underlying operating system. (ATLWL-102)",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"1",
"2",
"3"
]
},
"remediations": [
{
"category": "mitigation",
"details": "CVE-2022-37890, CVE-2022-37891, CVE-2022-37892, CVE-2022-37895, CVE-2022-37896: Restrict the web-based management interface to a dedicated layer 2 segment/VLAN and/or control the interface by firewall policies at layer 3 and above",
"product_ids": [
"1",
"2",
"3"
]
},
{
"category": "vendor_fix",
"details": "Update to V8.7.1.11 or later version",
"product_ids": [
"1",
"2",
"3"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109816886/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:T/RC:C",
"version": "3.1"
},
"products": [
"1",
"2",
"3"
]
}
],
"title": "CVE-2022-37890"
},
{
"cve": "CVE-2022-37891",
"cwe": {
"id": "CWE-120",
"name": "Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)"
},
"notes": [
{
"category": "summary",
"text": "An unauthenticated buffer overflow vulnerability exists within the web management interface. Successful exploitation results in the execution of arbitrary commands on the underlying operating system. (ATLWL-268)",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"1",
"2",
"3"
]
},
"remediations": [
{
"category": "mitigation",
"details": "CVE-2022-37890, CVE-2022-37891, CVE-2022-37892, CVE-2022-37895, CVE-2022-37896: Restrict the web-based management interface to a dedicated layer 2 segment/VLAN and/or control the interface by firewall policies at layer 3 and above",
"product_ids": [
"1",
"2",
"3"
]
},
{
"category": "vendor_fix",
"details": "Update to V8.7.1.11 or later version",
"product_ids": [
"1",
"2",
"3"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109816886/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:T/RC:C",
"version": "3.1"
},
"products": [
"1",
"2",
"3"
]
}
],
"title": "CVE-2022-37891"
},
{
"cve": "CVE-2022-37892",
"cwe": {
"id": "CWE-79",
"name": "Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)"
},
"notes": [
{
"category": "summary",
"text": "A vulnerability in the web management interface could allow an unauthenticated remote attacker to conduct a stored cross-site scripting (XSS) attack against a user of the interface. A successful exploit could allow an attacker to execute arbitrary script code in a victim\u2019s browser in the context of the affected interface. (ATLWL-168)",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"1",
"2",
"3"
]
},
"remediations": [
{
"category": "mitigation",
"details": "CVE-2022-37890, CVE-2022-37891, CVE-2022-37892, CVE-2022-37895, CVE-2022-37896: Restrict the web-based management interface to a dedicated layer 2 segment/VLAN and/or control the interface by firewall policies at layer 3 and above",
"product_ids": [
"1",
"2",
"3"
]
},
{
"category": "vendor_fix",
"details": "Update to V8.7.1.11 or later version",
"product_ids": [
"1",
"2",
"3"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109816886/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 5.4,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N/E:P/RL:T/RC:C",
"version": "3.1"
},
"products": [
"1",
"2",
"3"
]
}
],
"title": "CVE-2022-37892"
},
{
"cve": "CVE-2022-37893",
"cwe": {
"id": "CWE-77",
"name": "Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)"
},
"notes": [
{
"category": "summary",
"text": "An authenticated command injection vulnerability exists in the command line interface. Successful exploitation of this vulnerability results in the ability to execute arbitrary commands as a privileged user on the underlying operating system. (ATLWL-97)",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"1",
"2",
"3"
]
},
"remediations": [
{
"category": "mitigation",
"details": "CVE-2022-37893: Restrict the command line interface to a dedicated layer 2 segment/VLAN and/or control the interface by firewall policies at layer 3 and above",
"product_ids": [
"1",
"2",
"3"
]
},
{
"category": "vendor_fix",
"details": "Update to V8.7.1.11 or later version",
"product_ids": [
"1",
"2",
"3"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109816886/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:T/RC:C",
"version": "3.1"
},
"products": [
"1",
"2",
"3"
]
}
],
"title": "CVE-2022-37893"
},
{
"cve": "CVE-2022-37894",
"cwe": {
"id": "CWE-20",
"name": "Improper Input Validation"
},
"notes": [
{
"category": "summary",
"text": "An unauthenticated denial of service (DoS) vulnerability exists in the handling of certain SSID strings. Successful exploitation of this vulnerability results in the ability to interrupt the normal operation of the affected Access Point. (ATLWL-242)",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"1",
"2",
"3"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V8.7.1.11 or later version",
"product_ids": [
"1",
"2",
"3"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109816886/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:T/RC:C",
"version": "3.1"
},
"products": [
"1",
"2",
"3"
]
}
],
"title": "CVE-2022-37894"
},
{
"cve": "CVE-2022-37895",
"cwe": {
"id": "CWE-20",
"name": "Improper Input Validation"
},
"notes": [
{
"category": "summary",
"text": "An authenticated denial of service (DoS) vulnerability exists in the web management interface. Successful exploitation of this vulnerability results in the ability to interrupt the normal operation of the affected Access Point. (ATLWL-248)",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"1",
"2",
"3"
]
},
"remediations": [
{
"category": "mitigation",
"details": "CVE-2022-37890, CVE-2022-37891, CVE-2022-37892, CVE-2022-37895, CVE-2022-37896: Restrict the web-based management interface to a dedicated layer 2 segment/VLAN and/or control the interface by firewall policies at layer 3 and above",
"product_ids": [
"1",
"2",
"3"
]
},
{
"category": "vendor_fix",
"details": "Update to V8.7.1.11 or later version",
"product_ids": [
"1",
"2",
"3"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109816886/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 4.9,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:H/E:P/RL:T/RC:C",
"version": "3.1"
},
"products": [
"1",
"2",
"3"
]
}
],
"title": "CVE-2022-37895"
},
{
"cve": "CVE-2022-37896",
"cwe": {
"id": "CWE-79",
"name": "Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)"
},
"notes": [
{
"category": "summary",
"text": "A vulnerability in the web management interface could allow a remote attacker to conduct a reflected cross-site scripting (XSS) attack against a user of the interface. A successful exploit could allow an attacker to execute arbitrary script code in a victim\u2019s browser in the context of the affected interface. (ATLWL-234)",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"1",
"2",
"3"
]
},
"remediations": [
{
"category": "mitigation",
"details": "CVE-2022-37890, CVE-2022-37891, CVE-2022-37892, CVE-2022-37895, CVE-2022-37896: Restrict the web-based management interface to a dedicated layer 2 segment/VLAN and/or control the interface by firewall policies at layer 3 and above",
"product_ids": [
"1",
"2",
"3"
]
},
{
"category": "vendor_fix",
"details": "Update to V8.7.1.11 or later version",
"product_ids": [
"1",
"2",
"3"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109816886/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 6.1,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N/E:P/RL:T/RC:C",
"version": "3.1"
},
"products": [
"1",
"2",
"3"
]
}
],
"title": "CVE-2022-37896"
}
]
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…