SSA-663999

Vulnerability from csaf_siemens - Published: 2021-02-09 00:00 - Updated: 2021-05-17 00:00
Summary
SSA-663999: Multiple File Parsing Vulnerabilities in JT2Go and Teamcenter Visualization before V13.1.0.1

Notes

Summary
Siemens has released version V13.1.0.1 for JT2Go and Teamcenter Visualization to fix multiple vulnerabilities that could be triggered when the products read files in different file formats (BMP, TIFF, CGM, TGA, PCT, HPG, PLT, RAS, PAR, ASM, DXF, DWG). If a user is tricked to opening of a malicious file with the affected products, this could lead to application crash, or potentially arbitrary code execution or data extraction on the target host system. Siemens recommends to update to the latest versions and to limit opening of untrusted files from unknown sources in the affected products. Notes: - Previous versions of this advisory incorrectly listed the following vulnerabilities as being fixed in V13.1.0.1: CVE-2020-26991, CVE-2020-26998, CVE-2020-26999, CVE-2020-27001 and CVE-2020-27002. Those were fixed in V13.1.0.2 and are therefore addressed in advisory SSA-695540 [0] - The vulnerability CVE-2020-28383 was incorrectly listed in SSA-622830 [1] as being fixed in V13.1.0.0. This was fixed in V13.1.0.1 and therefore added here - The Open Design Alliance [2] recently disclosed an additional vulnerability (CVE-2021-31784) which is also covered in this advisory [0] https://cert-portal.siemens.com/productcert/pdf/ssa-622830.pdf [1] https://cert-portal.siemens.com/productcert/pdf/ssa-695540.pdf [2] https://www.opendesign.com/security-advisories
General Recommendations
As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity
Additional Resources
For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories
Terms of Use
Siemens Security Advisories are subject to the terms and conditions contained in Siemens' underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter "License Terms"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens' Global Website (https://www.siemens.com/terms_of_use, hereinafter "Terms of Use"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.

{
  "document": {
    "acknowledgments": [
      {
        "organization": "Trend Micro Zero Day Initiative",
        "summary": "coordinated disclosure"
      },
      {
        "organization": "Open Design Alliance",
        "summary": "coordination efforts"
      },
      {
        "organization": "Cybersecurity and Infrastructure Security Agency (CISA)",
        "summary": "coordination efforts"
      }
    ],
    "category": "Siemens Security Advisory",
    "csaf_version": "2.0",
    "distribution": {
      "text": "Disclosure is not limited.",
      "tlp": {
        "label": "WHITE"
      }
    },
    "notes": [
      {
        "category": "summary",
        "text": "Siemens has released version V13.1.0.1 for JT2Go and Teamcenter Visualization to fix multiple vulnerabilities that could be triggered when the products read files in different file formats (BMP, TIFF, CGM, TGA, PCT, HPG, PLT, RAS, PAR, ASM, DXF, DWG). If a user is tricked to opening of a malicious file with the affected products, this could lead to application crash, or potentially arbitrary code execution or data extraction on the target host system.\n\nSiemens recommends to update to the latest versions and to limit opening of untrusted files from unknown sources in the affected products.\n\nNotes:\n\n-   Previous versions of this advisory incorrectly listed the following vulnerabilities as being fixed in V13.1.0.1: CVE-2020-26991, CVE-2020-26998, CVE-2020-26999, CVE-2020-27001 and CVE-2020-27002. Those were fixed in V13.1.0.2 and are therefore addressed in advisory SSA-695540 [0]\n\n-   The vulnerability CVE-2020-28383 was incorrectly listed in SSA-622830 [1] as being fixed in V13.1.0.0. This was fixed in V13.1.0.1 and therefore added here\n\n-   The Open Design Alliance [2] recently disclosed an additional vulnerability (CVE-2021-31784) which is also covered in this advisory\n\n[0] https://cert-portal.siemens.com/productcert/pdf/ssa-622830.pdf\n\n[1] https://cert-portal.siemens.com/productcert/pdf/ssa-695540.pdf\n\n[2] https://www.opendesign.com/security-advisories",
        "title": "Summary"
      },
      {
        "category": "general",
        "text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity",
        "title": "General Recommendations"
      },
      {
        "category": "general",
        "text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories",
        "title": "Additional Resources"
      },
      {
        "category": "legal_disclaimer",
        "text": "Siemens Security Advisories are subject to the terms and conditions contained in Siemens\u0027 underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter \"License Terms\"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens\u0027 Global Website (https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.",
        "title": "Terms of Use"
      }
    ],
    "publisher": {
      "category": "vendor",
      "contact_details": "productcert@siemens.com",
      "name": "Siemens ProductCERT",
      "namespace": "https://www.siemens.com"
    },
    "references": [
      {
        "category": "self",
        "summary": "SSA-663999: Multiple File Parsing Vulnerabilities in JT2Go and Teamcenter Visualization before V13.1.0.1 - PDF Version",
        "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-663999.pdf"
      },
      {
        "category": "self",
        "summary": "SSA-663999: Multiple File Parsing Vulnerabilities in JT2Go and Teamcenter Visualization before V13.1.0.1 - TXT Version",
        "url": "https://cert-portal.siemens.com/productcert/txt/ssa-663999.txt"
      },
      {
        "category": "self",
        "summary": "SSA-663999: Multiple File Parsing Vulnerabilities in JT2Go and Teamcenter Visualization before V13.1.0.1 - CSAF Version",
        "url": "https://cert-portal.siemens.com/productcert/csaf/ssa-663999.json"
      }
    ],
    "title": "SSA-663999: Multiple File Parsing Vulnerabilities in JT2Go and Teamcenter Visualization before V13.1.0.1",
    "tracking": {
      "current_release_date": "2021-05-17T00:00:00Z",
      "generator": {
        "engine": {
          "name": "Siemens ProductCERT CSAF Generator",
          "version": "1"
        }
      },
      "id": "SSA-663999",
      "initial_release_date": "2021-02-09T00:00:00Z",
      "revision_history": [
        {
          "date": "2021-02-09T00:00:00Z",
          "legacy_version": "1.0",
          "number": "1",
          "summary": "Publication Date"
        },
        {
          "date": "2021-05-17T00:00:00Z",
          "legacy_version": "1.1",
          "number": "2",
          "summary": "Removed the vulnerabilities CVE-2020-26991, CVE-2020-26998, CVE-2020-26999, CVE-2020-27001, CVE-2020-27002, and added CVE-2020-28383, CVE-2021-31784 for the reasons described in the Summary"
        }
      ],
      "status": "final",
      "version": "2"
    }
  },
  "product_tree": {
    "branches": [
      {
        "branches": [
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "\u003c V13.1.0.1",
                "product": {
                  "name": "JT2Go",
                  "product_id": "1"
                }
              }
            ],
            "category": "product_name",
            "name": "JT2Go"
          },
          {
            "branches": [
              {
                "category": "product_version_range",
                "name": "\u003c V13.1.0.1",
                "product": {
                  "name": "Teamcenter Visualization",
                  "product_id": "2"
                }
              }
            ],
            "category": "product_name",
            "name": "Teamcenter Visualization"
          }
        ],
        "category": "vendor",
        "name": "Siemens"
      }
    ]
  },
  "vulnerabilities": [
    {
      "cve": "CVE-2020-26989",
      "cwe": {
        "id": "CWE-121",
        "name": "Stack-based Buffer Overflow"
      },
      "notes": [
        {
          "category": "summary",
          "text": "Affected applications lack proper validation of user-supplied data when parsing of PAR files. This could result in a stack based buffer overflow. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-11892)",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "1",
          "2"
        ]
      },
      "references": [
        {
          "summary": "CVE-2020-26989 - JT2Go",
          "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html"
        },
        {
          "summary": "CVE-2020-26989 Mitre 5.0 json",
          "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2020-26989.json"
        }
      ],
      "remediations": [
        {
          "category": "vendor_fix",
          "details": "Update to V13.1.0.1 or later version",
          "product_ids": [
            "1"
          ],
          "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html"
        },
        {
          "category": "vendor_fix",
          "details": "Update to V13.1.0.1 or later version",
          "product_ids": [
            "2"
          ]
        },
        {
          "category": "mitigation",
          "details": "Avoid to open untrusted files from unknown sources in JT2Go and Teamcenter Visualization",
          "product_ids": [
            "1",
            "2"
          ]
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          },
          "products": [
            "1",
            "2"
          ]
        }
      ],
      "title": "CVE-2020-26989"
    },
    {
      "cve": "CVE-2020-26990",
      "cwe": {
        "id": "CWE-843",
        "name": "Access of Resource Using Incompatible Type (\u0027Type Confusion\u0027)"
      },
      "notes": [
        {
          "category": "summary",
          "text": "Affected applications lack proper validation of user-supplied data when parsing ASM files. A crafted ASM file could trigger a type confusion condition. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-11897)",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "1",
          "2"
        ]
      },
      "references": [
        {
          "summary": "CVE-2020-26990 - JT2Go",
          "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html"
        },
        {
          "summary": "CVE-2020-26990 Mitre 5.0 json",
          "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2020-26990.json"
        }
      ],
      "remediations": [
        {
          "category": "vendor_fix",
          "details": "Update to V13.1.0.1 or later version",
          "product_ids": [
            "1"
          ],
          "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html"
        },
        {
          "category": "vendor_fix",
          "details": "Update to V13.1.0.1 or later version",
          "product_ids": [
            "2"
          ]
        },
        {
          "category": "mitigation",
          "details": "Avoid to open untrusted files from unknown sources in JT2Go and Teamcenter Visualization",
          "product_ids": [
            "1",
            "2"
          ]
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          },
          "products": [
            "1",
            "2"
          ]
        }
      ],
      "title": "CVE-2020-26990"
    },
    {
      "cve": "CVE-2020-27000",
      "cwe": {
        "id": "CWE-119",
        "name": "Improper Restriction of Operations within the Bounds of a Memory Buffer"
      },
      "notes": [
        {
          "category": "summary",
          "text": "Affected applications lack proper validation of user-supplied data when parsing BMP files. This can result in a memory corruption condition. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-12018)",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "1",
          "2"
        ]
      },
      "references": [
        {
          "summary": "CVE-2020-27000 - JT2Go",
          "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html"
        },
        {
          "summary": "CVE-2020-27000 Mitre 5.0 json",
          "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2020-27000.json"
        }
      ],
      "remediations": [
        {
          "category": "vendor_fix",
          "details": "Update to V13.1.0.1 or later version",
          "product_ids": [
            "1"
          ],
          "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html"
        },
        {
          "category": "vendor_fix",
          "details": "Update to V13.1.0.1 or later version",
          "product_ids": [
            "2"
          ]
        },
        {
          "category": "mitigation",
          "details": "Avoid to open untrusted files from unknown sources in JT2Go and Teamcenter Visualization",
          "product_ids": [
            "1",
            "2"
          ]
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          },
          "products": [
            "1",
            "2"
          ]
        }
      ],
      "title": "CVE-2020-27000"
    },
    {
      "cve": "CVE-2020-27003",
      "cwe": {
        "id": "CWE-822",
        "name": "Untrusted Pointer Dereference"
      },
      "notes": [
        {
          "category": "summary",
          "text": "Affected applications lack proper validation of user-supplied data when parsing TIFF files. This could lead to pointer dereferences of a value obtained from untrusted source. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-12158)",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "1",
          "2"
        ]
      },
      "references": [
        {
          "summary": "CVE-2020-27003 - JT2Go",
          "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html"
        },
        {
          "summary": "CVE-2020-27003 Mitre 5.0 json",
          "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2020-27003.json"
        }
      ],
      "remediations": [
        {
          "category": "vendor_fix",
          "details": "Update to V13.1.0.1 or later version",
          "product_ids": [
            "1"
          ],
          "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html"
        },
        {
          "category": "vendor_fix",
          "details": "Update to V13.1.0.1 or later version",
          "product_ids": [
            "2"
          ]
        },
        {
          "category": "mitigation",
          "details": "Avoid to open untrusted files from unknown sources in JT2Go and Teamcenter Visualization",
          "product_ids": [
            "1",
            "2"
          ]
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          },
          "products": [
            "1",
            "2"
          ]
        }
      ],
      "title": "CVE-2020-27003"
    },
    {
      "cve": "CVE-2020-27004",
      "cwe": {
        "id": "CWE-125",
        "name": "Out-of-bounds Read"
      },
      "notes": [
        {
          "category": "summary",
          "text": "Affected applications lack proper validation of user-supplied data when parsing of CGM files. This could result in a memory access past the end of an allocated buffer. An attacker could leverage this vulnerability to access data in the context of the current process. (ZDI-CAN-12163)",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "1",
          "2"
        ]
      },
      "references": [
        {
          "summary": "CVE-2020-27004 - JT2Go",
          "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html"
        },
        {
          "summary": "CVE-2020-27004 Mitre 5.0 json",
          "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2020-27004.json"
        }
      ],
      "remediations": [
        {
          "category": "vendor_fix",
          "details": "Update to V13.1.0.1 or later version",
          "product_ids": [
            "1"
          ],
          "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html"
        },
        {
          "category": "vendor_fix",
          "details": "Update to V13.1.0.1 or later version",
          "product_ids": [
            "2"
          ]
        },
        {
          "category": "mitigation",
          "details": "Avoid to open untrusted files from unknown sources in JT2Go and Teamcenter Visualization",
          "product_ids": [
            "1",
            "2"
          ]
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          },
          "products": [
            "1",
            "2"
          ]
        }
      ],
      "title": "CVE-2020-27004"
    },
    {
      "cve": "CVE-2020-27005",
      "cwe": {
        "id": "CWE-787",
        "name": "Out-of-bounds Write"
      },
      "notes": [
        {
          "category": "summary",
          "text": "Affected applications lack proper validation of user-supplied data when parsing of TGA files. This could result in an out of bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-12178)",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "1",
          "2"
        ]
      },
      "references": [
        {
          "summary": "CVE-2020-27005 - JT2Go",
          "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html"
        },
        {
          "summary": "CVE-2020-27005 Mitre 5.0 json",
          "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2020-27005.json"
        }
      ],
      "remediations": [
        {
          "category": "vendor_fix",
          "details": "Update to V13.1.0.1 or later version",
          "product_ids": [
            "1"
          ],
          "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html"
        },
        {
          "category": "vendor_fix",
          "details": "Update to V13.1.0.1 or later version",
          "product_ids": [
            "2"
          ]
        },
        {
          "category": "mitigation",
          "details": "Avoid to open untrusted files from unknown sources in JT2Go and Teamcenter Visualization",
          "product_ids": [
            "1",
            "2"
          ]
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          },
          "products": [
            "1",
            "2"
          ]
        }
      ],
      "title": "CVE-2020-27005"
    },
    {
      "cve": "CVE-2020-27006",
      "cwe": {
        "id": "CWE-119",
        "name": "Improper Restriction of Operations within the Bounds of a Memory Buffer"
      },
      "notes": [
        {
          "category": "summary",
          "text": "Affected applications lack proper validation of user-supplied data when parsing of PCT files. This could result in a memory corruption condition. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-12182)",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "1",
          "2"
        ]
      },
      "references": [
        {
          "summary": "CVE-2020-27006 - JT2Go",
          "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html"
        },
        {
          "summary": "CVE-2020-27006 Mitre 5.0 json",
          "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2020-27006.json"
        }
      ],
      "remediations": [
        {
          "category": "vendor_fix",
          "details": "Update to V13.1.0.1 or later version",
          "product_ids": [
            "1"
          ],
          "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html"
        },
        {
          "category": "vendor_fix",
          "details": "Update to V13.1.0.1 or later version",
          "product_ids": [
            "2"
          ]
        },
        {
          "category": "mitigation",
          "details": "Avoid to open untrusted files from unknown sources in JT2Go and Teamcenter Visualization",
          "product_ids": [
            "1",
            "2"
          ]
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          },
          "products": [
            "1",
            "2"
          ]
        }
      ],
      "title": "CVE-2020-27006"
    },
    {
      "cve": "CVE-2020-27007",
      "cwe": {
        "id": "CWE-125",
        "name": "Out-of-bounds Read"
      },
      "notes": [
        {
          "category": "summary",
          "text": "Affected applications lack proper validation of user-supplied data when parsing of HPG files. This could result in a memory access past the end of an allocated buffer. An attacker could leverage this vulnerability to access data in the context of the current process. (ZDI-CAN-12207)",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "1",
          "2"
        ]
      },
      "references": [
        {
          "summary": "CVE-2020-27007 - JT2Go",
          "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html"
        },
        {
          "summary": "CVE-2020-27007 Mitre 5.0 json",
          "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2020-27007.json"
        }
      ],
      "remediations": [
        {
          "category": "vendor_fix",
          "details": "Update to V13.1.0.1 or later version",
          "product_ids": [
            "1"
          ],
          "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html"
        },
        {
          "category": "vendor_fix",
          "details": "Update to V13.1.0.1 or later version",
          "product_ids": [
            "2"
          ]
        },
        {
          "category": "mitigation",
          "details": "Avoid to open untrusted files from unknown sources in JT2Go and Teamcenter Visualization",
          "product_ids": [
            "1",
            "2"
          ]
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          },
          "products": [
            "1",
            "2"
          ]
        }
      ],
      "title": "CVE-2020-27007"
    },
    {
      "cve": "CVE-2020-27008",
      "cwe": {
        "id": "CWE-125",
        "name": "Out-of-bounds Read"
      },
      "notes": [
        {
          "category": "summary",
          "text": "Affected applications lack proper validation of user-supplied data when parsing of PLT files. This could result in a memory access past the end of an allocated buffer. An attacker could leverage this vulnerability to access data in the context of the current process. (ZDI-CAN-12209)",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "1",
          "2"
        ]
      },
      "references": [
        {
          "summary": "CVE-2020-27008 - JT2Go",
          "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html"
        },
        {
          "summary": "CVE-2020-27008 Mitre 5.0 json",
          "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2020-27008.json"
        }
      ],
      "remediations": [
        {
          "category": "vendor_fix",
          "details": "Update to V13.1.0.1 or later version",
          "product_ids": [
            "1"
          ],
          "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html"
        },
        {
          "category": "vendor_fix",
          "details": "Update to V13.1.0.1 or later version",
          "product_ids": [
            "2"
          ]
        },
        {
          "category": "mitigation",
          "details": "Avoid to open untrusted files from unknown sources in JT2Go and Teamcenter Visualization",
          "product_ids": [
            "1",
            "2"
          ]
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          },
          "products": [
            "1",
            "2"
          ]
        }
      ],
      "title": "CVE-2020-27008"
    },
    {
      "cve": "CVE-2020-28383",
      "cwe": {
        "id": "CWE-787",
        "name": "Out-of-bounds Write"
      },
      "notes": [
        {
          "category": "summary",
          "text": "Affected applications lack proper validation of user-supplied data when parsing PAR files. This can result in an out of bounds write past the memory location that is a read only image address. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-11885)",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "1",
          "2"
        ]
      },
      "references": [
        {
          "summary": "CVE-2020-28383 - JT2Go",
          "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html"
        },
        {
          "summary": "CVE-2020-28383 Mitre 5.0 json",
          "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2020-28383.json"
        }
      ],
      "remediations": [
        {
          "category": "vendor_fix",
          "details": "Update to V13.1.0.1 or later version",
          "product_ids": [
            "1"
          ],
          "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html"
        },
        {
          "category": "vendor_fix",
          "details": "Update to V13.1.0.1 or later version",
          "product_ids": [
            "2"
          ]
        },
        {
          "category": "mitigation",
          "details": "Avoid to open untrusted files from unknown sources in JT2Go and Teamcenter Visualization",
          "product_ids": [
            "1",
            "2"
          ]
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          },
          "products": [
            "1",
            "2"
          ]
        }
      ],
      "title": "CVE-2020-28383"
    },
    {
      "cve": "CVE-2020-28394",
      "cwe": {
        "id": "CWE-125",
        "name": "Out-of-bounds Read"
      },
      "notes": [
        {
          "category": "summary",
          "text": "Affected applications lack proper validation of user-supplied data when parsing of RAS files. This could result in a memory access past the end of an allocated buffer. An attacker could leverage this vulnerability to access data in the context of the current process. (ZDI-CAN-12283)",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "1",
          "2"
        ]
      },
      "references": [
        {
          "summary": "CVE-2020-28394 - JT2Go",
          "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html"
        },
        {
          "summary": "CVE-2020-28394 Mitre 5.0 json",
          "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2020-28394.json"
        }
      ],
      "remediations": [
        {
          "category": "vendor_fix",
          "details": "Update to V13.1.0.1 or later version",
          "product_ids": [
            "1"
          ],
          "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html"
        },
        {
          "category": "vendor_fix",
          "details": "Update to V13.1.0.1 or later version",
          "product_ids": [
            "2"
          ]
        },
        {
          "category": "mitigation",
          "details": "Avoid to open untrusted files from unknown sources in JT2Go and Teamcenter Visualization",
          "product_ids": [
            "1",
            "2"
          ]
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          },
          "products": [
            "1",
            "2"
          ]
        }
      ],
      "title": "CVE-2020-28394"
    },
    {
      "cve": "CVE-2021-25173",
      "cwe": {
        "id": "CWE-789",
        "name": "Memory Allocation with Excessive Size Value"
      },
      "notes": [
        {
          "category": "summary",
          "text": "An issue was discovered in Open Design Alliance Drawings SDK before 2021.12. A memory allocation with excessive size vulnerability exists when reading malformed DGN files, which could allow attackers to cause a crash, potentially enabling denial of service (crash, exit, or restart). (ZDI-CAN-12019)",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "1",
          "2"
        ]
      },
      "references": [
        {
          "summary": "CVE-2021-25173 - JT2Go",
          "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html"
        },
        {
          "summary": "CVE-2021-25173 Mitre 5.0 json",
          "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-25173.json"
        }
      ],
      "remediations": [
        {
          "category": "vendor_fix",
          "details": "Update to V13.1.0.1 or later version",
          "product_ids": [
            "1"
          ],
          "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html"
        },
        {
          "category": "vendor_fix",
          "details": "Update to V13.1.0.1 or later version",
          "product_ids": [
            "2"
          ]
        },
        {
          "category": "mitigation",
          "details": "Avoid to open untrusted files from unknown sources in JT2Go and Teamcenter Visualization",
          "product_ids": [
            "1",
            "2"
          ]
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          },
          "products": [
            "1",
            "2"
          ]
        }
      ],
      "title": "CVE-2021-25173"
    },
    {
      "cve": "CVE-2021-25174",
      "cwe": {
        "id": "CWE-789",
        "name": "Memory Allocation with Excessive Size Value"
      },
      "notes": [
        {
          "category": "summary",
          "text": "An issue was discovered in Open Design Alliance Drawings SDK before 2021.12. A memory corruption vulnerability exists when reading malformed DGN files. It could allow attackers to cause a crash, potentially enabling denial of service (Crash, Exit, or Restart). (ZDI-CAN-12026)",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "1",
          "2"
        ]
      },
      "references": [
        {
          "summary": "CVE-2021-25174 - JT2Go",
          "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html"
        },
        {
          "summary": "CVE-2021-25174 Mitre 5.0 json",
          "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-25174.json"
        }
      ],
      "remediations": [
        {
          "category": "vendor_fix",
          "details": "Update to V13.1.0.1 or later version",
          "product_ids": [
            "1"
          ],
          "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html"
        },
        {
          "category": "vendor_fix",
          "details": "Update to V13.1.0.1 or later version",
          "product_ids": [
            "2"
          ]
        },
        {
          "category": "mitigation",
          "details": "Avoid to open untrusted files from unknown sources in JT2Go and Teamcenter Visualization",
          "product_ids": [
            "1",
            "2"
          ]
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          },
          "products": [
            "1",
            "2"
          ]
        }
      ],
      "title": "CVE-2021-25174"
    },
    {
      "cve": "CVE-2021-25175",
      "cwe": {
        "id": "CWE-822",
        "name": "Untrusted Pointer Dereference"
      },
      "notes": [
        {
          "category": "summary",
          "text": "An issue was discovered in Open Design Alliance Drawings SDK before 2021.11. A Type Conversion issue exists when rendering malformed .DXF and .DWG files. This could allow attackers to cause a crash, potentially enabling a denial of service attack (Crash, Exit, or Restart). (ZDI-CAN-11912, ZDI-CAN-11993, ZDI-CAN-11988)",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "1",
          "2"
        ]
      },
      "references": [
        {
          "summary": "CVE-2021-25175 - JT2Go",
          "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html"
        },
        {
          "summary": "CVE-2021-25175 Mitre 5.0 json",
          "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-25175.json"
        }
      ],
      "remediations": [
        {
          "category": "vendor_fix",
          "details": "Update to V13.1.0.1 or later version",
          "product_ids": [
            "1"
          ],
          "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html"
        },
        {
          "category": "vendor_fix",
          "details": "Update to V13.1.0.1 or later version",
          "product_ids": [
            "2"
          ]
        },
        {
          "category": "mitigation",
          "details": "Avoid to open untrusted files from unknown sources in JT2Go and Teamcenter Visualization",
          "product_ids": [
            "1",
            "2"
          ]
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          },
          "products": [
            "1",
            "2"
          ]
        }
      ],
      "title": "CVE-2021-25175"
    },
    {
      "cve": "CVE-2021-25176",
      "cwe": {
        "id": "CWE-822",
        "name": "Untrusted Pointer Dereference"
      },
      "notes": [
        {
          "category": "summary",
          "text": "An issue was discovered in Open Design Alliance Drawings SDK before 2021.11. A NULL pointer dereference exists when rendering malformed .DXF and .DWG files. This could allow attackers to cause a crash, potentially enabling a denial of service attack (Crash, Exit, or Restart). (ZDI-CAN-11913, ZDI-CAN-11989)",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "1",
          "2"
        ]
      },
      "references": [
        {
          "summary": "CVE-2021-25176 - JT2Go",
          "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html"
        },
        {
          "summary": "CVE-2021-25176 Mitre 5.0 json",
          "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-25176.json"
        }
      ],
      "remediations": [
        {
          "category": "vendor_fix",
          "details": "Update to V13.1.0.1 or later version",
          "product_ids": [
            "1"
          ],
          "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html"
        },
        {
          "category": "vendor_fix",
          "details": "Update to V13.1.0.1 or later version",
          "product_ids": [
            "2"
          ]
        },
        {
          "category": "mitigation",
          "details": "Avoid to open untrusted files from unknown sources in JT2Go and Teamcenter Visualization",
          "product_ids": [
            "1",
            "2"
          ]
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          },
          "products": [
            "1",
            "2"
          ]
        }
      ],
      "title": "CVE-2021-25176"
    },
    {
      "cve": "CVE-2021-25177",
      "cwe": {
        "id": "CWE-843",
        "name": "Access of Resource Using Incompatible Type (\u0027Type Confusion\u0027)"
      },
      "notes": [
        {
          "category": "summary",
          "text": "An issue was discovered in Open Design Alliance Drawings SDK before 2021.11. A Type Confusion issue exists when rendering malformed .DXF and .DWG files. (ZDI-CAN-11927)",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "1",
          "2"
        ]
      },
      "references": [
        {
          "summary": "CVE-2021-25177 - JT2Go",
          "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html"
        },
        {
          "summary": "CVE-2021-25177 Mitre 5.0 json",
          "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-25177.json"
        }
      ],
      "remediations": [
        {
          "category": "vendor_fix",
          "details": "Update to V13.1.0.1 or later version",
          "product_ids": [
            "1"
          ],
          "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html"
        },
        {
          "category": "vendor_fix",
          "details": "Update to V13.1.0.1 or later version",
          "product_ids": [
            "2"
          ]
        },
        {
          "category": "mitigation",
          "details": "Avoid to open untrusted files from unknown sources in JT2Go and Teamcenter Visualization",
          "product_ids": [
            "1",
            "2"
          ]
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          },
          "products": [
            "1",
            "2"
          ]
        }
      ],
      "title": "CVE-2021-25177"
    },
    {
      "cve": "CVE-2021-25178",
      "cwe": {
        "id": "CWE-121",
        "name": "Stack-based Buffer Overflow"
      },
      "notes": [
        {
          "category": "summary",
          "text": "An issue was discovered in Open Design Alliance Drawings SDK before 2021.11. A stack-based buffer overflow vulnerability exists when the recover operation is run with malformed .DXF and .DWG files. (ZDI-CAN-11901, ZDI-CAN-12165, ZDI-CAN-12166)",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "1",
          "2"
        ]
      },
      "references": [
        {
          "summary": "CVE-2021-25178 - JT2Go",
          "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html"
        },
        {
          "summary": "CVE-2021-25178 Mitre 5.0 json",
          "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-25178.json"
        }
      ],
      "remediations": [
        {
          "category": "vendor_fix",
          "details": "Update to V13.1.0.1 or later version",
          "product_ids": [
            "1"
          ],
          "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html"
        },
        {
          "category": "vendor_fix",
          "details": "Update to V13.1.0.1 or later version",
          "product_ids": [
            "2"
          ]
        },
        {
          "category": "mitigation",
          "details": "Avoid to open untrusted files from unknown sources in JT2Go and Teamcenter Visualization",
          "product_ids": [
            "1",
            "2"
          ]
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          },
          "products": [
            "1",
            "2"
          ]
        }
      ],
      "title": "CVE-2021-25178"
    },
    {
      "cve": "CVE-2021-31784",
      "cwe": {
        "id": "CWE-787",
        "name": "Out-of-bounds Write"
      },
      "notes": [
        {
          "category": "summary",
          "text": "An out-of-bounds write vulnerability exists in the file-reading procedure in Open Design Alliance Drawings SDK before 2021.6.\n\nThis could allow an attacker to cause a crash, potentially enabling a denial of service attack (Crash, Exit, or Restart) or possible code execution. (ZDI-CAN-11915)",
          "title": "Summary"
        }
      ],
      "product_status": {
        "known_affected": [
          "1",
          "2"
        ]
      },
      "references": [
        {
          "summary": "CVE-2021-31784 - JT2Go",
          "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html"
        },
        {
          "summary": "CVE-2021-31784 Mitre 5.0 json",
          "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-31784.json"
        }
      ],
      "remediations": [
        {
          "category": "vendor_fix",
          "details": "Update to V13.1.0.1 or later version",
          "product_ids": [
            "1"
          ],
          "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html"
        },
        {
          "category": "vendor_fix",
          "details": "Update to V13.1.0.1 or later version",
          "product_ids": [
            "2"
          ]
        },
        {
          "category": "mitigation",
          "details": "Avoid to open untrusted files from unknown sources in JT2Go and Teamcenter Visualization",
          "product_ids": [
            "1",
            "2"
          ]
        }
      ],
      "scores": [
        {
          "cvss_v3": {
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          },
          "products": [
            "1",
            "2"
          ]
        }
      ],
      "title": "CVE-2021-31784"
    }
  ]
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.


Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…