SSA-744259
Vulnerability from csaf_siemens - Published: 2023-02-14 00:00 - Updated: 2023-02-14 00:00Summary
SSA-744259: Golang Vulnerabilities in Brownfield Connectivity - Gateway before V1.10.1
Notes
Summary
Siemens has released a new version for Brownfield Connectivity - Gateway that contains fixes for multiple vulnerabilities in the underlying Golang implementation. Successful exploitation of these vulnerabilities could lead to Denial of Service (DoS).
Siemens has released an update for Brownfield Connectivity - Gateway and recommends to update to the latest version.
General Recommendations
As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download:
https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.
Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity
Additional Resources
For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories
Terms of Use
Siemens Security Advisories are subject to the terms and conditions contained in Siemens' underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter "License Terms"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens' Global Website (https://www.siemens.com/terms_of_use, hereinafter "Terms of Use"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.
{
"document": {
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Disclosure is not limited. (TLPv2: TLP:CLEAR)",
"tlp": {
"label": "WHITE"
}
},
"notes": [
{
"category": "summary",
"text": "Siemens has released a new version for Brownfield Connectivity - Gateway that contains fixes for multiple vulnerabilities in the underlying Golang implementation. Successful exploitation of these vulnerabilities could lead to Denial of Service (DoS).\n\nSiemens has released an update for Brownfield Connectivity - Gateway and recommends to update to the latest version.",
"title": "Summary"
},
{
"category": "general",
"text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity",
"title": "General Recommendations"
},
{
"category": "general",
"text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories",
"title": "Additional Resources"
},
{
"category": "legal_disclaimer",
"text": "Siemens Security Advisories are subject to the terms and conditions contained in Siemens\u0027 underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter \"License Terms\"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens\u0027 Global Website (https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.",
"title": "Terms of Use"
}
],
"publisher": {
"category": "vendor",
"contact_details": "productcert@siemens.com",
"name": "Siemens ProductCERT",
"namespace": "https://www.siemens.com"
},
"references": [
{
"category": "self",
"summary": "SSA-744259: Golang Vulnerabilities in Brownfield Connectivity - Gateway before V1.10.1 - PDF Version",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-744259.pdf"
},
{
"category": "self",
"summary": "SSA-744259: Golang Vulnerabilities in Brownfield Connectivity - Gateway before V1.10.1 - TXT Version",
"url": "https://cert-portal.siemens.com/productcert/txt/ssa-744259.txt"
},
{
"category": "self",
"summary": "SSA-744259: Golang Vulnerabilities in Brownfield Connectivity - Gateway before V1.10.1 - CSAF Version",
"url": "https://cert-portal.siemens.com/productcert/csaf/ssa-744259.json"
}
],
"title": "SSA-744259: Golang Vulnerabilities in Brownfield Connectivity - Gateway before V1.10.1",
"tracking": {
"current_release_date": "2023-02-14T00:00:00Z",
"generator": {
"engine": {
"name": "Siemens ProductCERT CSAF Generator",
"version": "1"
}
},
"id": "SSA-744259",
"initial_release_date": "2023-02-14T00:00:00Z",
"revision_history": [
{
"date": "2023-02-14T00:00:00Z",
"legacy_version": "1.0",
"number": "1",
"summary": "Publication Date"
}
],
"status": "final",
"version": "1"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c V1.10",
"product": {
"name": "Brownfield Connectivity - Gateway",
"product_id": "1"
}
},
{
"category": "product_version_range",
"name": "V1.10.1",
"product": {
"name": "Brownfield Connectivity - Gateway",
"product_id": "2"
}
}
],
"category": "product_name",
"name": "Brownfield Connectivity - Gateway"
}
],
"category": "vendor",
"name": "Siemens"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2021-41771",
"cwe": {
"id": "CWE-119",
"name": "Improper Restriction of Operations within the Bounds of a Memory Buffer"
},
"notes": [
{
"category": "summary",
"text": "ImportedSymbols in debug/macho (for Open or OpenFat) in Go before 1.16.10 and 1.17.x before 1.17.3 Accesses a Memory Location After the End of a Buffer, aka an out-of-bounds slice situation.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"1"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V1.11 or later version\nContact customer support to obtain the update \u003chttps://support.industry.siemens.com/cs/de/de/view/109801700\u003e",
"product_ids": [
"1"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"1"
]
}
],
"title": "CVE-2021-41771"
},
{
"cve": "CVE-2021-41772",
"cwe": {
"id": "CWE-20",
"name": "Improper Input Validation"
},
"notes": [
{
"category": "summary",
"text": "Go before 1.16.10 and 1.17.x before 1.17.3 allows an archive/zip Reader.Open panic via a crafted ZIP archive containing an invalid name or an empty filename field.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"1"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V1.11 or later version\nContact customer support to obtain the update \u003chttps://support.industry.siemens.com/cs/de/de/view/109801700\u003e",
"product_ids": [
"1"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"1"
]
}
],
"title": "CVE-2021-41772"
},
{
"cve": "CVE-2021-44716",
"cwe": {
"id": "CWE-400",
"name": "Uncontrolled Resource Consumption"
},
"notes": [
{
"category": "summary",
"text": "net/http in Go before 1.16.12 and 1.17.x before 1.17.5 allows uncontrolled memory consumption in the header canonicalization cache via HTTP/2 requests.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"1"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V1.11 or later version\nContact customer support to obtain the update \u003chttps://support.industry.siemens.com/cs/de/de/view/109801700\u003e",
"product_ids": [
"1"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"1"
]
}
],
"title": "CVE-2021-44716"
},
{
"cve": "CVE-2021-44717",
"cwe": {
"id": "CWE-668",
"name": "Exposure of Resource to Wrong Sphere"
},
"notes": [
{
"category": "summary",
"text": "Go before 1.16.12 and 1.17.x before 1.17.5 on UNIX allows write operations to an unintended file or unintended network connection as a consequence of erroneous closing of file descriptor 0 after file-descriptor exhaustion.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"1"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V1.11 or later version\nContact customer support to obtain the update \u003chttps://support.industry.siemens.com/cs/de/de/view/109801700\u003e",
"product_ids": [
"1"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 4.8,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:L/A:N/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"1"
]
}
],
"title": "CVE-2021-44717"
},
{
"cve": "CVE-2022-24675",
"cwe": {
"id": "CWE-770",
"name": "Allocation of Resources Without Limits or Throttling"
},
"notes": [
{
"category": "summary",
"text": "encoding/pem in Go before 1.17.9 and 1.18.x before 1.18.1 has a Decode stack overflow via a large amount of PEM data.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"1",
"2"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V1.11 or later version\nContact customer support to obtain the update \u003chttps://support.industry.siemens.com/cs/de/de/view/109801700\u003e",
"product_ids": [
"1",
"2"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"1",
"2"
]
}
],
"title": "CVE-2022-24675"
},
{
"cve": "CVE-2022-24921",
"cwe": {
"id": "CWE-400",
"name": "Uncontrolled Resource Consumption"
},
"notes": [
{
"category": "summary",
"text": "regexp.Compile in Go before 1.16.15 and 1.17.x before 1.17.8 allows stack exhaustion via a deeply nested expression.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"1"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V1.11 or later version\nContact customer support to obtain the update \u003chttps://support.industry.siemens.com/cs/de/de/view/109801700\u003e",
"product_ids": [
"1"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"1"
]
}
],
"title": "CVE-2022-24921"
},
{
"cve": "CVE-2022-27536",
"cwe": {
"id": "CWE-295",
"name": "Improper Certificate Validation"
},
"notes": [
{
"category": "summary",
"text": "Certificate.Verify in crypto/x509 in Go 1.18.x before 1.18.1 can be caused to panic on macOS when presented with certain malformed certificates. This allows a remote TLS server to cause a TLS client to panic.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"1",
"2"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V1.11 or later version\nContact customer support to obtain the update \u003chttps://support.industry.siemens.com/cs/de/de/view/109801700\u003e",
"product_ids": [
"1",
"2"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"1",
"2"
]
}
],
"title": "CVE-2022-27536"
},
{
"cve": "CVE-2022-28327",
"cwe": {
"id": "CWE-20",
"name": "Improper Input Validation"
},
"notes": [
{
"category": "summary",
"text": "The generic P-256 feature in crypto/elliptic in Go before 1.17.9 and 1.18.x before 1.18.1 allows a panic via long scalar input.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"1",
"2"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Update to V1.11 or later version\nContact customer support to obtain the update \u003chttps://support.industry.siemens.com/cs/de/de/view/109801700\u003e",
"product_ids": [
"1",
"2"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"1",
"2"
]
}
],
"title": "CVE-2022-28327"
}
]
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…