A CWE-119 Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists in IGSS Definition (Def.exe) version 14.0.0.20247 and prior that could cause Remote Code Execution when malicious CGF (Configuration Group File) file is imported to IGSS Definition. Interactive Graphical SCADA System (IGSS) Is Schneider Electric Software for monitoring and controlling control systems provided by the company. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Schneider Electric IGSS. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.The specific flaw exists within the parsing of CGF files. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a stack-based buffer. An attacker can leverage this vulnerability to execute code in the context of the current process.

IGSS version 14.0.0.20247 and earlier have a buffer overflow vulnerability. The vulnerability stems from inappropriate restrictions on operations within the memory buffer boundary

Show details on source website

{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202011-1286",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "interactive graphical scada system",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "schneider electric",
        "version": "14.0.0.20247"
      },
      {
        "model": "interactive graphical scada system",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "schneider electric",
        "version": "version 14.0.0.20247"
      },
      {
        "model": "igss",
        "scope": null,
        "trust": 0.7,
        "vendor": "schneider electric",
        "version": null
      },
      {
        "model": "electric interactive graphical scada system",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "schneider",
        "version": "14.0.0.20247"
      }
    ],
    "sources": [
      {
        "db": "ZDI",
        "id": "ZDI-21-092"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2020-70530"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-009593"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-7550"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "children": [],
            "cpe_match": [
              {
                "cpe23Uri": "cpe:2.3:a:schneider-electric:interactive_graphical_scada_system:*:*:*:*:*:*:*:*",
                "cpe_name": [],
                "versionEndIncluding": "14.0.0.20247",
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2020-7550"
      }
    ]
  },
  "credits": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/credits#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "kimiya",
    "sources": [
      {
        "db": "ZDI",
        "id": "ZDI-21-092"
      }
    ],
    "trust": 0.7
  },
  "cve": "CVE-2020-7550",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "acInsufInfo": false,
            "accessComplexity": "MEDIUM",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "NVD",
            "availabilityImpact": "PARTIAL",
            "baseScore": 6.8,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 8.6,
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "severity": "MEDIUM",
            "trust": 1.0,
            "userInteractionRequired": true,
            "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          },
          {
            "accessComplexity": "MEDIUM",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "PARTIAL",
            "baseScore": 6.8,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 8.6,
            "id": "CNVD-2020-70530",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "MEDIUM",
            "trust": 0.6,
            "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          },
          {
            "accessComplexity": "MEDIUM",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "VULHUB",
            "availabilityImpact": "PARTIAL",
            "baseScore": 6.8,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 8.6,
            "id": "VHN-185675",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "MEDIUM",
            "trust": 0.1,
            "vectorString": "AV:N/AC:M/AU:N/C:P/I:P/A:P",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "Low",
            "attackVector": "Local",
            "author": "IPA score",
            "availabilityImpact": "High",
            "baseScore": 7.8,
            "baseSeverity": "High",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "JVNDB-2020-009593",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 7.2,
            "userInteraction": "Required",
            "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.0"
          },
          {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "author": "NVD",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 1.8,
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "author": "ZDI",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 1.8,
            "id": "CVE-2020-7550",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 0.7,
            "userInteraction": "REQUIRED",
            "vectorString": "AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "IPA",
            "id": "JVNDB-2020-009593",
            "trust": 7.2,
            "value": "High"
          },
          {
            "author": "NVD",
            "id": "CVE-2020-7550",
            "trust": 1.0,
            "value": "HIGH"
          },
          {
            "author": "ZDI",
            "id": "CVE-2020-7550",
            "trust": 0.7,
            "value": "HIGH"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2020-70530",
            "trust": 0.6,
            "value": "MEDIUM"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202011-1567",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "VULHUB",
            "id": "VHN-185675",
            "trust": 0.1,
            "value": "MEDIUM"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "ZDI",
        "id": "ZDI-21-092"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2020-70530"
      },
      {
        "db": "VULHUB",
        "id": "VHN-185675"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-009593"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-009593"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-009593"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-009593"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-009593"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-009593"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-009593"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-009593"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-009593"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-7550"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202011-1567"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "A CWE-119 Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists in IGSS Definition (Def.exe) version 14.0.0.20247 and prior that could cause Remote Code Execution when malicious CGF (Configuration Group File) file is imported to IGSS Definition. Interactive Graphical SCADA System (IGSS) Is Schneider Electric Software for monitoring and controlling control systems provided by the company. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Schneider Electric IGSS. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.The specific flaw exists within the parsing of CGF files. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a stack-based buffer. An attacker can leverage this vulnerability to execute code in the context of the current process. \n\r\n\r\nIGSS version 14.0.0.20247 and earlier have a buffer overflow vulnerability. The vulnerability stems from inappropriate restrictions on operations within the memory buffer boundary",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2020-7550"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-009593"
      },
      {
        "db": "ZDI",
        "id": "ZDI-21-092"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2020-70530"
      },
      {
        "db": "VULHUB",
        "id": "VHN-185675"
      }
    ],
    "trust": 2.88
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2020-7550",
        "trust": 3.8
      },
      {
        "db": "ZDI",
        "id": "ZDI-21-092",
        "trust": 2.4
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-20-324-04",
        "trust": 2.0
      },
      {
        "db": "SCHNEIDER",
        "id": "SEVD-2020-315-03",
        "trust": 1.7
      },
      {
        "db": "JVN",
        "id": "JVNVU99979220",
        "trust": 0.8
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-009593",
        "trust": 0.8
      },
      {
        "db": "ZDI_CAN",
        "id": "ZDI-CAN-11168",
        "trust": 0.7
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202011-1567",
        "trust": 0.7
      },
      {
        "db": "CNVD",
        "id": "CNVD-2020-70530",
        "trust": 0.6
      },
      {
        "db": "AUSCERT",
        "id": "ESB-2020.4088",
        "trust": 0.6
      },
      {
        "db": "VULHUB",
        "id": "VHN-185675",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "ZDI",
        "id": "ZDI-21-092"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2020-70530"
      },
      {
        "db": "VULHUB",
        "id": "VHN-185675"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-009593"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-7550"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202011-1567"
      }
    ]
  },
  "id": "VAR-202011-1286",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2020-70530"
      },
      {
        "db": "VULHUB",
        "id": "VHN-185675"
      }
    ],
    "trust": 1.6749999999999998
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "ICS"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2020-70530"
      }
    ]
  },
  "last_update_date": "2023-12-18T12:16:42.926000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "Security Notification - Interactive Graphical SCADA System (IGSS)",
        "trust": 0.8,
        "url": "https://www.se.com/ww/en/download/document/sevd-2020-315-03"
      },
      {
        "title": "IGSS Licensed Versions",
        "trust": 0.8,
        "url": "https://igss.schneider-electric.com/licensed-versions"
      },
      {
        "title": "Schneider Electric has issued an update to correct this vulnerability.",
        "trust": 0.7,
        "url": "https://www.se.com/ww/en/download/document/sevd-2020-315-03/"
      },
      {
        "title": "Patch for Schneider Electric Interactive Graphical SCADA System buffer overflow vulnerability (CNVD-2020-70530)",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchinfo/show/241747"
      },
      {
        "title": "Schneider Electric Interactive Graphical SCADA System Buffer error vulnerability fix",
        "trust": 0.6,
        "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=135155"
      }
    ],
    "sources": [
      {
        "db": "ZDI",
        "id": "ZDI-21-092"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2020-70530"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-009593"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202011-1567"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-119",
        "trust": 1.9
      },
      {
        "problemtype": "CWE-787",
        "trust": 0.8
      },
      {
        "problemtype": "CWE-125",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-185675"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-009593"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-7550"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.4,
        "url": "https://www.se.com/ww/en/download/document/sevd-2020-315-03/"
      },
      {
        "trust": 2.0,
        "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-324-04"
      },
      {
        "trust": 1.7,
        "url": "https://www.zerodayinitiative.com/advisories/zdi-21-092/"
      },
      {
        "trust": 0.8,
        "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2020-7550"
      },
      {
        "trust": 0.8,
        "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2020-7558"
      },
      {
        "trust": 0.8,
        "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2020-7551"
      },
      {
        "trust": 0.8,
        "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2020-7552"
      },
      {
        "trust": 0.8,
        "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2020-7553"
      },
      {
        "trust": 0.8,
        "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2020-7554"
      },
      {
        "trust": 0.8,
        "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2020-7555"
      },
      {
        "trust": 0.8,
        "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2020-7556"
      },
      {
        "trust": 0.8,
        "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2020-7557"
      },
      {
        "trust": 0.8,
        "url": "https://jvn.jp/vu/jvnvu99979220"
      },
      {
        "trust": 0.6,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2020-7550"
      },
      {
        "trust": 0.6,
        "url": "https://www.auscert.org.au/bulletins/esb-2020.4088/"
      }
    ],
    "sources": [
      {
        "db": "ZDI",
        "id": "ZDI-21-092"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2020-70530"
      },
      {
        "db": "VULHUB",
        "id": "VHN-185675"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-009593"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-7550"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202011-1567"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "ZDI",
        "id": "ZDI-21-092"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2020-70530"
      },
      {
        "db": "VULHUB",
        "id": "VHN-185675"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-009593"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-7550"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202011-1567"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2021-01-29T00:00:00",
        "db": "ZDI",
        "id": "ZDI-21-092"
      },
      {
        "date": "2020-11-17T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2020-70530"
      },
      {
        "date": "2020-11-19T00:00:00",
        "db": "VULHUB",
        "id": "VHN-185675"
      },
      {
        "date": "2020-11-19T08:46:47",
        "db": "JVNDB",
        "id": "JVNDB-2020-009593"
      },
      {
        "date": "2020-11-19T22:15:14.177000",
        "db": "NVD",
        "id": "CVE-2020-7550"
      },
      {
        "date": "2020-11-17T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202011-1567"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2021-01-29T00:00:00",
        "db": "ZDI",
        "id": "ZDI-21-092"
      },
      {
        "date": "2020-12-10T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2020-70530"
      },
      {
        "date": "2021-02-01T00:00:00",
        "db": "VULHUB",
        "id": "VHN-185675"
      },
      {
        "date": "2020-11-19T08:46:47",
        "db": "JVNDB",
        "id": "JVNDB-2020-009593"
      },
      {
        "date": "2021-02-01T17:38:31.087000",
        "db": "NVD",
        "id": "CVE-2020-7550"
      },
      {
        "date": "2021-02-01T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202011-1567"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "local",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202011-1567"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Schneider Electric Made  Interactive Graphical SCADA System Multiple vulnerabilities in",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-009593"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "buffer error",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202011-1567"
      }
    ],
    "trust": 0.6
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.


Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…