A CWE-311: Missing Encryption of Sensitive Data vulnerability exists in Easergy T300 (firmware 2.7 and older), that would allow an attacker to read network traffic over HTTP protocol. Easergy T300 There is a vulnerability in the lack of encryption of critical data.Information may be obtained. Easergy T300 is a new generation of distribution network automation intelligent terminal, adhering to the "modularity, flexibility, application-oriented" design concept, can be widely used in medium voltage distribution network management, fault location, isolation and recovery (FLISR), distributed energy integration Internet, energy growth and asset management.

Easergy T300 2.7 and earlier versions have security vulnerabilities

Show details on source website

{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202012-0817",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "easergy t300",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "schneider electric",
        "version": "2.7"
      },
      {
        "model": "easergy t300",
        "scope": "lte",
        "trust": 0.8,
        "vendor": "schneider electric",
        "version": "easergy t300  firmware  2.7  and earlier"
      },
      {
        "model": "easergy t300",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "schneider electric",
        "version": null
      },
      {
        "model": "electric easergy t300",
        "scope": "lte",
        "trust": 0.6,
        "vendor": "schneider",
        "version": "\u003c=2.7"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-19763"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-014345"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-28217"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:schneider-electric:easergy_t300_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndIncluding": "2.7",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:schneider-electric:easergy_t300:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2020-28217"
      }
    ]
  },
  "cve": "CVE-2020-28217",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "acInsufInfo": false,
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "NVD",
            "availabilityImpact": "NONE",
            "baseScore": 5.0,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "impactScore": 2.9,
            "integrityImpact": "NONE",
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "severity": "MEDIUM",
            "trust": 1.0,
            "userInteractionRequired": false,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
            "version": "2.0"
          },
          {
            "acInsufInfo": null,
            "accessComplexity": "Low",
            "accessVector": "Network",
            "authentication": "None",
            "author": "NVD",
            "availabilityImpact": "None",
            "baseScore": 5.0,
            "confidentialityImpact": "Partial",
            "exploitabilityScore": null,
            "id": "CVE-2020-28217",
            "impactScore": null,
            "integrityImpact": "None",
            "obtainAllPrivilege": null,
            "obtainOtherPrivilege": null,
            "obtainUserPrivilege": null,
            "severity": "Medium",
            "trust": 0.8,
            "userInteractionRequired": null,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "NONE",
            "baseScore": 5.0,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "id": "CNVD-2021-19763",
            "impactScore": 2.9,
            "integrityImpact": "NONE",
            "severity": "MEDIUM",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "NVD",
            "availabilityImpact": "NONE",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "impactScore": 3.6,
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "None",
            "baseScore": 7.5,
            "baseSeverity": "High",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "CVE-2020-28217",
            "impactScore": null,
            "integrityImpact": "None",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "NVD",
            "id": "CVE-2020-28217",
            "trust": 1.8,
            "value": "HIGH"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2021-19763",
            "trust": 0.6,
            "value": "MEDIUM"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202012-725",
            "trust": 0.6,
            "value": "HIGH"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-19763"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-014345"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-28217"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202012-725"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "A CWE-311: Missing Encryption of Sensitive Data vulnerability exists in Easergy T300 (firmware 2.7 and older), that would allow an attacker to read network traffic over HTTP protocol. Easergy T300 There is a vulnerability in the lack of encryption of critical data.Information may be obtained. Easergy T300 is a new generation of distribution network automation intelligent terminal, adhering to the \"modularity, flexibility, application-oriented\" design concept, can be widely used in medium voltage distribution network management, fault location, isolation and recovery (FLISR), distributed energy integration Internet, energy growth and asset management. \n\r\n\r\nEasergy T300 2.7 and earlier versions have security vulnerabilities",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2020-28217"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-014345"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2021-19763"
      }
    ],
    "trust": 2.16
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2020-28217",
        "trust": 3.0
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-20-343-03",
        "trust": 3.0
      },
      {
        "db": "SCHNEIDER",
        "id": "SEVD-2020-315-06",
        "trust": 1.6
      },
      {
        "db": "JVN",
        "id": "JVNVU91936841",
        "trust": 0.8
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-014345",
        "trust": 0.8
      },
      {
        "db": "CNVD",
        "id": "CNVD-2021-19763",
        "trust": 0.6
      },
      {
        "db": "AUSCERT",
        "id": "ESB-2020.4360",
        "trust": 0.6
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202012-725",
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-19763"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-014345"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-28217"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202012-725"
      }
    ]
  },
  "id": "VAR-202012-0817",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-19763"
      }
    ],
    "trust": 1.6
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "IoT"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-19763"
      }
    ]
  },
  "last_update_date": "2023-12-18T12:27:06.016000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "SEVD-2020-315-06",
        "trust": 0.8,
        "url": "https://www.se.com/ww/en/download/document/sevd-2020-315-06/"
      },
      {
        "title": "Patch for Schneider Electric Easergy T300 has an unspecified vulnerability (CNVD-2021-19763)",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchinfo/show/253996"
      },
      {
        "title": "Schneider Electric Easergy T300 Fixes for access control error vulnerabilities",
        "trust": 0.6,
        "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=137260"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-19763"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-014345"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202012-725"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-311",
        "trust": 1.0
      },
      {
        "problemtype": "Lack of encryption of critical data (CWE-311) [ Other ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-014345"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-28217"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 3.6,
        "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-343-03"
      },
      {
        "trust": 1.6,
        "url": "https://www.se.com/ww/en/download/document/sevd-2020-315-06/"
      },
      {
        "trust": 1.4,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2020-28217"
      },
      {
        "trust": 0.8,
        "url": "https://jvn.jp/vu/jvnvu91936841/"
      },
      {
        "trust": 0.6,
        "url": "https://www.auscert.org.au/bulletins/esb-2020.4360/"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-19763"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-014345"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-28217"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202012-725"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-19763"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-014345"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-28217"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202012-725"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2021-03-22T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2021-19763"
      },
      {
        "date": "2021-08-13T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2020-014345"
      },
      {
        "date": "2020-12-11T01:15:11.707000",
        "db": "NVD",
        "id": "CVE-2020-28217"
      },
      {
        "date": "2020-12-08T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202012-725"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2021-03-22T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2021-19763"
      },
      {
        "date": "2021-08-13T09:04:00",
        "db": "JVNDB",
        "id": "JVNDB-2020-014345"
      },
      {
        "date": "2020-12-14T14:51:06.997000",
        "db": "NVD",
        "id": "CVE-2020-28217"
      },
      {
        "date": "2020-12-16T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202012-725"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202012-725"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Easergy\u00a0T300\u00a0 Vulnerability regarding lack of encryption of critical data in",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-014345"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "access control error",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202012-725"
      }
    ],
    "trust": 0.6
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.


Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…