var-202101-0318
Vulnerability from variot
Dell EMC Isilon OneFS versions 8.1 and later and Dell EMC PowerScale OneFS version 9.0.0 contain a privilege escalation vulnerability on a SmartLock Compliance mode cluster. The compadmin user connecting using ISI PRIV LOGIN SSH or ISI PRIV LOGIN CONSOLE can elevate privileges to the root user if they have ISI PRIV HARDENING privileges
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202101-0318", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "emc powerscale onefs", "scope": "eq", "trust": 1.0, "vendor": "dell", "version": "9.0.0" }, { "model": "emc isilon onefs", "scope": "lte", "trust": 1.0, "vendor": "dell", "version": "8.1.0.0" }, { "model": "dell emc isilon onefs", "scope": null, "trust": 0.8, "vendor": "\u30c7\u30eb", "version": null }, { "model": "emc powerscale onefs", "scope": null, "trust": 0.8, "vendor": "\u30c7\u30eb", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-015136" }, { "db": "NVD", "id": "CVE-2020-26181" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:a:dell:emc_isilon_onefs:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndIncluding": "8.1.0.0", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:o:dell:emc_powerscale_onefs:9.0.0:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2020-26181" } ] }, "cve": "CVE-2020-26181", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "LOW", "accessVector": "LOCAL", "authentication": "NONE", "author": "NVD", "availabilityImpact": "COMPLETE", "baseScore": 7.2, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 3.9, "impactScore": 10.0, "integrityImpact": "COMPLETE", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "HIGH", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:L/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Local", "authentication": "None", "author": "NVD", "availabilityImpact": "Complete", "baseScore": 7.2, "confidentialityImpact": "Complete", "exploitabilityScore": null, "id": "CVE-2020-26181", "impactScore": null, "integrityImpact": "Complete", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "High", "trust": 0.8, "userInteractionRequired": null, "vectorString": "AV:L/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "LOCAL", "authentication": "NONE", "author": "VULHUB", "availabilityImpact": "COMPLETE", "baseScore": 7.2, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 3.9, "id": "VHN-180234", "impactScore": 10.0, "integrityImpact": "COMPLETE", "severity": "HIGH", "trust": 0.1, "vectorString": "AV:L/AC:L/AU:N/C:C/I:C/A:C", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "LOCAL", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 1.8, "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "HIGH", "attackVector": "LOCAL", "author": "security_alert@emc.com", "availabilityImpact": "HIGH", "baseScore": 7.0, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 1.0, "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Local", "author": "NVD", "availabilityImpact": "High", "baseScore": 7.8, "baseSeverity": "High", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2020-26181", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "Low", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2020-26181", "trust": 1.8, "value": "HIGH" }, { "author": "security_alert@emc.com", "id": "CVE-2020-26181", "trust": 1.0, "value": "HIGH" }, { "author": "CNNVD", "id": "CNNVD-202101-233", "trust": 0.6, "value": "HIGH" }, { "author": "VULHUB", "id": "VHN-180234", "trust": 0.1, "value": "HIGH" } ] } ], "sources": [ { "db": "VULHUB", "id": "VHN-180234" }, { "db": "JVNDB", "id": "JVNDB-2020-015136" }, { "db": "NVD", "id": "CVE-2020-26181" }, { "db": "NVD", "id": "CVE-2020-26181" }, { "db": "CNNVD", "id": "CNNVD-202101-233" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Dell EMC Isilon OneFS versions 8.1 and later and Dell EMC PowerScale OneFS version 9.0.0 contain a privilege escalation vulnerability on a SmartLock Compliance mode cluster. The compadmin user connecting using ISI PRIV LOGIN SSH or ISI PRIV LOGIN CONSOLE can elevate privileges to the root user if they have ISI PRIV HARDENING privileges", "sources": [ { "db": "NVD", "id": "CVE-2020-26181" }, { "db": "JVNDB", "id": "JVNDB-2020-015136" }, { "db": "VULHUB", "id": "VHN-180234" } ], "trust": 1.71 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2020-26181", "trust": 2.5 }, { "db": "JVNDB", "id": "JVNDB-2020-015136", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-202101-233", "trust": 0.6 }, { "db": "VULHUB", "id": "VHN-180234", "trust": 0.1 } ], "sources": [ { "db": "VULHUB", "id": "VHN-180234" }, { "db": "JVNDB", "id": "JVNDB-2020-015136" }, { "db": "NVD", "id": "CVE-2020-26181" }, { "db": "CNNVD", "id": "CNNVD-202101-233" } ] }, "id": "VAR-202101-0318", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VULHUB", "id": "VHN-180234" } ], "trust": 0.01 }, "last_update_date": "2023-12-18T12:27:04.329000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "DSA-2020-227", "trust": 0.8, "url": "https://www.dell.com/support/kbdoc/ja-jp/000180922/dsa-2020-227-dell-emc-powerscale-onefs-and-dell-emc-isilon-onefs-security-update-for-smartlock-compliance-mode-privilege-escalation-vulnerability" }, { "title": "Dell EMC Isilon OneFS and Dell EMC PowerScale Security vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=138389" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-015136" }, { "db": "CNNVD", "id": "CNNVD-202101-233" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "NVD-CWE-noinfo", "trust": 1.0 }, { "problemtype": "Improper authority management (CWE-269) [NVD Evaluation ]", "trust": 0.8 }, { "problemtype": "CWE-269", "trust": 0.1 } ], "sources": [ { "db": "VULHUB", "id": "VHN-180234" }, { "db": "JVNDB", "id": "JVNDB-2020-015136" }, { "db": "NVD", "id": "CVE-2020-26181" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.7, "url": "https://www.dell.com/support/security/en-us/details/546720/dsa-2020-227-dell-emc-powerscale-onefs-and-dell-emc-isilon-onefs-security-update-for-smartlock-co" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2020-26181" } ], "sources": [ { "db": "VULHUB", "id": "VHN-180234" }, { "db": "JVNDB", "id": "JVNDB-2020-015136" }, { "db": "NVD", "id": "CVE-2020-26181" }, { "db": "CNNVD", "id": "CNNVD-202101-233" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULHUB", "id": "VHN-180234" }, { "db": "JVNDB", "id": "JVNDB-2020-015136" }, { "db": "NVD", "id": "CVE-2020-26181" }, { "db": "CNNVD", "id": "CNNVD-202101-233" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-01-05T00:00:00", "db": "VULHUB", "id": "VHN-180234" }, { "date": "2021-09-10T00:00:00", "db": "JVNDB", "id": "JVNDB-2020-015136" }, { "date": "2021-01-05T22:15:13.673000", "db": "NVD", "id": "CVE-2020-26181" }, { "date": "2021-01-05T00:00:00", "db": "CNNVD", "id": "CNNVD-202101-233" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-10-04T00:00:00", "db": "VULHUB", "id": "VHN-180234" }, { "date": "2021-09-10T08:55:00", "db": "JVNDB", "id": "JVNDB-2020-015136" }, { "date": "2021-10-04T17:31:34.703000", "db": "NVD", "id": "CVE-2020-26181" }, { "date": "2021-10-08T00:00:00", "db": "CNNVD", "id": "CNNVD-202101-233" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "local", "sources": [ { "db": "CNNVD", "id": "CNNVD-202101-233" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Dell\u00a0EMC\u00a0Isilon\u00a0OneFS\u00a0 and \u00a0Dell\u00a0EMC\u00a0PowerScale\u00a0OneFS\u00a0 Vulnerability in privilege management", "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-015136" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "other", "sources": [ { "db": "CNNVD", "id": "CNNVD-202101-233" } ], "trust": 0.6 } }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.