VAR-202103-0441
Vulnerability from variot - Updated: 2023-12-18 11:57A CWE-119:Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists in Interactive Graphical SCADA System (IGSS) Definition (Def.exe) V15.0.0.21041 and prior, which could cause remote code execution when malicious CGF (Configuration Group File) file is imported to IGSS Definition. Interactive Graphical SCADA System (IGSS) Is vulnerable to a buffer error.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Schneider Electric IGSS. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.The specific flaw exists within the parsing of CGF files. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a stack-based buffer. An attacker can leverage this vulnerability to execute code in the context of the current process. Schneider Electric Interactive Graphical SCADA System (IGSS) is a set of SCADA (data acquisition and monitoring system) system used to monitor and control industrial processes of Schneider Electric in France
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202103-0441",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "interactive graphical scada system",
"scope": "lte",
"trust": 1.0,
"vendor": "schneider electric",
"version": "15.0.0.21041"
},
{
"model": "interactive graphical scada system",
"scope": "lte",
"trust": 0.8,
"vendor": "schneider electric",
"version": "15.0.0.21041 and earlier"
},
{
"model": "interactive graphical scada system",
"scope": "eq",
"trust": 0.8,
"vendor": "schneider electric",
"version": null
},
{
"model": "igss",
"scope": null,
"trust": 0.7,
"vendor": "schneider electric",
"version": null
}
],
"sources": [
{
"db": "ZDI",
"id": "ZDI-21-271"
},
{
"db": "JVNDB",
"id": "JVNDB-2021-004462"
},
{
"db": "NVD",
"id": "CVE-2021-22710"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:a:schneider-electric:interactive_graphical_scada_system:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "15.0.0.21041",
"vulnerable": true
}
],
"operator": "OR"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2021-22710"
}
]
},
"credits": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/credits#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "kimiya",
"sources": [
{
"db": "ZDI",
"id": "ZDI-21-271"
}
],
"trust": 0.7
},
"cve": "CVE-2021-22710",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"acInsufInfo": false,
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "NVD",
"availabilityImpact": "COMPLETE",
"baseScore": 9.3,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 8.6,
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "HIGH",
"trust": 1.0,
"userInteractionRequired": true,
"vectorString": "AV:N/AC:M/Au:N/C:C/I:C/A:C",
"version": "2.0"
},
{
"acInsufInfo": null,
"accessComplexity": "Medium",
"accessVector": "Network",
"authentication": "None",
"author": "NVD",
"availabilityImpact": "Complete",
"baseScore": 9.3,
"confidentialityImpact": "Complete",
"exploitabilityScore": null,
"id": "CVE-2021-22710",
"impactScore": null,
"integrityImpact": "Complete",
"obtainAllPrivilege": null,
"obtainOtherPrivilege": null,
"obtainUserPrivilege": null,
"severity": "High",
"trust": 0.8,
"userInteractionRequired": null,
"vectorString": "AV:N/AC:M/Au:N/C:C/I:C/A:C",
"version": "2.0"
},
{
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "VULHUB",
"availabilityImpact": "COMPLETE",
"baseScore": 9.3,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 8.6,
"id": "VHN-381184",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.1,
"vectorString": "AV:N/AC:M/AU:N/C:C/I:C/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"author": "NVD",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 1.8,
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Local",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 7.8,
"baseSeverity": "High",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "CVE-2021-22710",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "Required",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.0"
},
{
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"author": "ZDI",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 1.8,
"id": "CVE-2021-22710",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 0.7,
"userInteraction": "REQUIRED",
"vectorString": "AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2021-22710",
"trust": 1.8,
"value": "HIGH"
},
{
"author": "ZDI",
"id": "CVE-2021-22710",
"trust": 0.7,
"value": "HIGH"
},
{
"author": "CNNVD",
"id": "CNNVD-202103-805",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "VULHUB",
"id": "VHN-381184",
"trust": 0.1,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "ZDI",
"id": "ZDI-21-271"
},
{
"db": "VULHUB",
"id": "VHN-381184"
},
{
"db": "JVNDB",
"id": "JVNDB-2021-004462"
},
{
"db": "NVD",
"id": "CVE-2021-22710"
},
{
"db": "CNNVD",
"id": "CNNVD-202103-805"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "A CWE-119:Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists in Interactive Graphical SCADA System (IGSS) Definition (Def.exe) V15.0.0.21041 and prior, which could cause remote code execution when malicious CGF (Configuration Group File) file is imported to IGSS Definition. Interactive Graphical SCADA System (IGSS) Is vulnerable to a buffer error.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Schneider Electric IGSS. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.The specific flaw exists within the parsing of CGF files. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a stack-based buffer. An attacker can leverage this vulnerability to execute code in the context of the current process. Schneider Electric Interactive Graphical SCADA System (IGSS) is a set of SCADA (data acquisition and monitoring system) system used to monitor and control industrial processes of Schneider Electric in France",
"sources": [
{
"db": "NVD",
"id": "CVE-2021-22710"
},
{
"db": "JVNDB",
"id": "JVNDB-2021-004462"
},
{
"db": "ZDI",
"id": "ZDI-21-271"
},
{
"db": "VULHUB",
"id": "VHN-381184"
}
],
"trust": 2.34
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2021-22710",
"trust": 3.2
},
{
"db": "SCHNEIDER",
"id": "SEVD-2021-068-01",
"trust": 1.7
},
{
"db": "ICS CERT",
"id": "ICSA-21-070-01",
"trust": 1.4
},
{
"db": "ZDI",
"id": "ZDI-21-271",
"trust": 1.3
},
{
"db": "JVN",
"id": "JVNVU92960744",
"trust": 0.8
},
{
"db": "JVNDB",
"id": "JVNDB-2021-004462",
"trust": 0.8
},
{
"db": "ZDI_CAN",
"id": "ZDI-CAN-12600",
"trust": 0.7
},
{
"db": "AUSCERT",
"id": "ESB-2021.0888",
"trust": 0.6
},
{
"db": "CNNVD",
"id": "CNNVD-202103-805",
"trust": 0.6
},
{
"db": "CNVD",
"id": "CNVD-2022-13075",
"trust": 0.1
},
{
"db": "VULHUB",
"id": "VHN-381184",
"trust": 0.1
}
],
"sources": [
{
"db": "ZDI",
"id": "ZDI-21-271"
},
{
"db": "VULHUB",
"id": "VHN-381184"
},
{
"db": "JVNDB",
"id": "JVNDB-2021-004462"
},
{
"db": "NVD",
"id": "CVE-2021-22710"
},
{
"db": "CNNVD",
"id": "CNNVD-202103-805"
}
]
},
"id": "VAR-202103-0441",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "VULHUB",
"id": "VHN-381184"
}
],
"trust": 0.01
},
"last_update_date": "2023-12-18T11:57:31.563000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Product\u00a0Documentation\u00a0\u0026\u00a0Software\u00a0downloads Schneider\u00a0Electric\u00a0Security\u00a0Notification",
"trust": 0.8,
"url": "https://www.se.com/ww/en/download/document/sevd-2021-068-01"
},
{
"title": "Schneider Electric has issued an update to correct this vulnerability.",
"trust": 0.7,
"url": "https://download.schneider-electric.com/files?p_doc_ref=sevd-2021-068-01"
},
{
"title": "Schneider Electric Interactive Graphical SCADA System Buffer error vulnerability fix",
"trust": 0.6,
"url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=144186"
}
],
"sources": [
{
"db": "ZDI",
"id": "ZDI-21-271"
},
{
"db": "JVNDB",
"id": "JVNDB-2021-004462"
},
{
"db": "CNNVD",
"id": "CNNVD-202103-805"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-119",
"trust": 1.1
},
{
"problemtype": "Buffer error (CWE-119) [ Other ]",
"trust": 0.8
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-381184"
},
{
"db": "JVNDB",
"id": "JVNDB-2021-004462"
},
{
"db": "NVD",
"id": "CVE-2021-22710"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.4,
"url": "https://download.schneider-electric.com/files?p_doc_ref=sevd-2021-068-01"
},
{
"trust": 1.7,
"url": "https://www.se.com/ww/en/download/document/sevd-2021-068-01"
},
{
"trust": 1.4,
"url": "https://nvd.nist.gov/vuln/detail/cve-2021-22710"
},
{
"trust": 1.4,
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-070-01"
},
{
"trust": 0.8,
"url": "http://jvn.jp/vu/jvnvu92960744/index.html"
},
{
"trust": 0.6,
"url": "https://www.auscert.org.au/bulletins/esb-2021.0888"
},
{
"trust": 0.6,
"url": "https://www.zerodayinitiative.com/advisories/zdi-21-271/"
}
],
"sources": [
{
"db": "ZDI",
"id": "ZDI-21-271"
},
{
"db": "VULHUB",
"id": "VHN-381184"
},
{
"db": "JVNDB",
"id": "JVNDB-2021-004462"
},
{
"db": "NVD",
"id": "CVE-2021-22710"
},
{
"db": "CNNVD",
"id": "CNNVD-202103-805"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "ZDI",
"id": "ZDI-21-271"
},
{
"db": "VULHUB",
"id": "VHN-381184"
},
{
"db": "JVNDB",
"id": "JVNDB-2021-004462"
},
{
"db": "NVD",
"id": "CVE-2021-22710"
},
{
"db": "CNNVD",
"id": "CNNVD-202103-805"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2021-03-11T00:00:00",
"db": "ZDI",
"id": "ZDI-21-271"
},
{
"date": "2021-03-11T00:00:00",
"db": "VULHUB",
"id": "VHN-381184"
},
{
"date": "2021-11-22T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2021-004462"
},
{
"date": "2021-03-11T21:15:12.170000",
"db": "NVD",
"id": "CVE-2021-22710"
},
{
"date": "2021-03-11T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202103-805"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2021-03-11T00:00:00",
"db": "ZDI",
"id": "ZDI-21-271"
},
{
"date": "2021-03-18T00:00:00",
"db": "VULHUB",
"id": "VHN-381184"
},
{
"date": "2021-11-22T08:59:00",
"db": "JVNDB",
"id": "JVNDB-2021-004462"
},
{
"date": "2021-03-18T19:31:00.227000",
"db": "NVD",
"id": "CVE-2021-22710"
},
{
"date": "2021-03-19T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202103-805"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "local",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202103-805"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Interactive\u00a0Graphical\u00a0SCADA\u00a0System\u00a0 Buffer Error Vulnerability",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2021-004462"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "buffer error",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202103-805"
}
],
"trust": 0.6
}
}
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.