var-202107-0330
Vulnerability from variot
Insufficiently Protected Credentials vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), and SCADAPack RemoteConnect for x70, all versions, that could cause unauthorized access to a project file protected by a password when this file is shared with untrusted sources. An attacker may bypass the password protection and be able to view and modify a project file. EcoStruxure Control Expert , EcoStruxure Process Expert , SCADAPack RemoteConnect Exists in an inadequate protection of credentials.Information may be obtained and information may be tampered with. Pillow is a Python-based image processing library. There is currently no information about this vulnerability, please feel free to follow CNNVD or manufacturer announcements
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202107-0330", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "remoteconnect", "scope": "eq", "trust": 1.0, "vendor": "schneider electric", "version": "*" }, { "model": "ecostruxure control expert", "scope": "lt", "trust": 1.0, "vendor": "schneider electric", "version": "15.0" }, { "model": "ecostruxure process expert", "scope": "eq", "trust": 1.0, "vendor": "schneider electric", "version": "*" }, { "model": "ecostruxure control expert", "scope": "eq", "trust": 1.0, "vendor": "schneider electric", "version": "15.0" }, { "model": "ecostruxure control expert", "scope": null, "trust": 0.8, "vendor": "schneider electric", "version": null }, { "model": "ecostruxure process expert", "scope": null, "trust": 0.8, "vendor": "schneider electric", "version": null }, { "model": "remoteconnect", "scope": null, "trust": 0.8, "vendor": "schneider electric", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-009772" }, { "db": "NVD", "id": "CVE-2021-22780" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:a:schneider-electric:ecostruxure_control_expert:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "15.0", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:schneider-electric:ecostruxure_control_expert:15.0:-:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:schneider-electric:ecostruxure_process_expert:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:schneider-electric:remoteconnect:*:*:*:*:*:*:scadapack_x70:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2021-22780" } ] }, "cve": "CVE-2021-22780", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "LOW", "accessVector": "LOCAL", "authentication": "NONE", "author": "NVD", "availabilityImpact": "NONE", "baseScore": 3.6, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 3.9, "id": "CVE-2021-22780", "impactScore": 4.9, "integrityImpact": "PARTIAL", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "LOW", "trust": 1.9, "userInteractionRequired": false, "vectorString": "AV:L/AC:L/Au:N/C:P/I:P/A:N", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "LOCAL", "author": "NVD", "availabilityImpact": "NONE", "baseScore": 7.1, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 1.8, "id": "CVE-2021-22780", "impactScore": 5.2, "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Local", "author": "NVD", "availabilityImpact": "None", "baseScore": 7.1, "baseSeverity": "High", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2021-22780", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "Low", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2021-22780", "trust": 1.8, "value": "HIGH" }, { "author": "CNNVD", "id": "CNNVD-202104-975", "trust": 0.6, "value": "MEDIUM" }, { "author": "CNNVD", "id": "CNNVD-202107-1023", "trust": 0.6, "value": "HIGH" }, { "author": "VULMON", "id": "CVE-2021-22780", "trust": 0.1, "value": "LOW" } ] } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-22780" }, { "db": "JVNDB", "id": "JVNDB-2021-009772" }, { "db": "CNNVD", "id": "CNNVD-202104-975" }, { "db": "CNNVD", "id": "CNNVD-202107-1023" }, { "db": "NVD", "id": "CVE-2021-22780" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Insufficiently Protected Credentials vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), and SCADAPack RemoteConnect for x70, all versions, that could cause unauthorized access to a project file protected by a password when this file is shared with untrusted sources. An attacker may bypass the password protection and be able to view and modify a project file. EcoStruxure Control Expert , EcoStruxure Process Expert , SCADAPack RemoteConnect Exists in an inadequate protection of credentials.Information may be obtained and information may be tampered with. Pillow is a Python-based image processing library. \nThere is currently no information about this vulnerability, please feel free to follow CNNVD or manufacturer announcements", "sources": [ { "db": "NVD", "id": "CVE-2021-22780" }, { "db": "JVNDB", "id": "JVNDB-2021-009772" }, { "db": "CNNVD", "id": "CNNVD-202104-975" }, { "db": "VULMON", "id": "CVE-2021-22780" } ], "trust": 2.25 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2021-22780", "trust": 3.3 }, { "db": "SCHNEIDER", "id": "SEVD-2021-194-01", "trust": 1.7 }, { "db": "JVN", "id": "JVNVU97215148", "trust": 0.8 }, { "db": "JVNDB", "id": "JVNDB-2021-009772", "trust": 0.8 }, { "db": "CS-HELP", "id": "SB2021041363", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-202104-975", "trust": 0.6 }, { "db": "CS-HELP", "id": "SB2021071414", "trust": 0.6 }, { "db": "AUSCERT", "id": "ESB-2021.2406", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-202107-1023", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2021-22780", "trust": 0.1 } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-22780" }, { "db": "JVNDB", "id": "JVNDB-2021-009772" }, { "db": "CNNVD", "id": "CNNVD-202104-975" }, { "db": "CNNVD", "id": "CNNVD-202107-1023" }, { "db": "NVD", "id": "CVE-2021-22780" } ] }, "id": "VAR-202107-0330", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.7375 }, "last_update_date": "2022-05-21T20:57:03.209000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "SEVD-2021-194-01", "trust": 0.8, "url": "https://download.schneider-electric.com/files?p_doc_ref=sevd-2021-194-01" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-009772" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-522", "trust": 1.0 }, { "problemtype": "Inadequate protection of credentials (CWE-522) [ Other ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-009772" }, { "db": "NVD", "id": "CVE-2021-22780" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.7, "url": "http://download.schneider-electric.com/files?p_doc_ref=sevd-2021-194-01" }, { "trust": 0.8, "url": "https://jvn.jp/vu/jvnvu97215148/" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-22780" }, { "trust": 0.6, "url": "https://www.cybersecurity-help.cz/vdb/sb2021041363" }, { "trust": 0.6, "url": "https://www.cybersecurity-help.cz/vdb/sb2021071414" }, { "trust": 0.6, "url": "https://www.auscert.org.au/bulletins/esb-2021.2406" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/522.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-22780" }, { "db": "JVNDB", "id": "JVNDB-2021-009772" }, { "db": "CNNVD", "id": "CNNVD-202104-975" }, { "db": "CNNVD", "id": "CNNVD-202107-1023" }, { "db": "NVD", "id": "CVE-2021-22780" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULMON", "id": "CVE-2021-22780" }, { "db": "JVNDB", "id": "JVNDB-2021-009772" }, { "db": "CNNVD", "id": "CNNVD-202104-975" }, { "db": "CNNVD", "id": "CNNVD-202107-1023" }, { "db": "NVD", "id": "CVE-2021-22780" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-07-14T00:00:00", "db": "VULMON", "id": "CVE-2021-22780" }, { "date": "2022-05-19T00:00:00", "db": "JVNDB", "id": "JVNDB-2021-009772" }, { "date": "2021-04-13T00:00:00", "db": "CNNVD", "id": "CNNVD-202104-975" }, { "date": "2021-07-14T00:00:00", "db": "CNNVD", "id": "CNNVD-202107-1023" }, { "date": "2021-07-14T15:15:00", "db": "NVD", "id": "CVE-2021-22780" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-07-26T00:00:00", "db": "VULMON", "id": "CVE-2021-22780" }, { "date": "2022-05-19T08:45:00", "db": "JVNDB", "id": "JVNDB-2021-009772" }, { "date": "2021-04-14T00:00:00", "db": "CNNVD", "id": "CNNVD-202104-975" }, { "date": "2021-08-12T00:00:00", "db": "CNNVD", "id": "CNNVD-202107-1023" }, { "date": "2021-07-26T13:58:00", "db": "NVD", "id": "CVE-2021-22780" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "local", "sources": [ { "db": "CNNVD", "id": "CNNVD-202107-1023" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural \u00a0Schneider\u00a0Electric\u00a0 Inadequate protection of credentials in products", "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-009772" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "other", "sources": [ { "db": "CNNVD", "id": "CNNVD-202104-975" }, { "db": "CNNVD", "id": "CNNVD-202107-1023" } ], "trust": 1.2 } }
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.