var-202109-1929
Vulnerability from variot

This vulnerability allows remote attackers to execute arbitrary code on affected installations of Schneider Electric Struxureware Data Center Expert. Authentication is required to exploit this vulnerability.The specific flaw exists within the testRepository method. The issue results from the lack of proper validation of a user-supplied string before using it to execute a system call. An attacker can leverage this vulnerability to execute code in the context of root

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202109-1929",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "struxureware data center expert",
        "scope": null,
        "trust": 0.7,
        "vendor": "schneider electric",
        "version": null
      }
    ],
    "sources": [
      {
        "db": "ZDI",
        "id": "ZDI-21-1072"
      }
    ]
  },
  "credits": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/credits#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "David Yesland",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202109-989"
      },
      {
        "db": "ZDI",
        "id": "ZDI-21-1072"
      }
    ],
    "trust": 1.3
  },
  "cve": "CVE-2021-22795",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "ZDI",
            "availabilityImpact": "HIGH",
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 2.8,
            "id": "CVE-2021-22795",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "trust": 0.7,
            "userInteraction": "NONE",
            "vectorString": "AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "ZDI",
            "id": "CVE-2021-22795",
            "trust": 0.7,
            "value": "HIGH"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202109-989",
            "trust": 0.6,
            "value": "HIGH"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202109-989"
      },
      {
        "db": "ZDI",
        "id": "ZDI-21-1072"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "This vulnerability allows remote attackers to execute arbitrary code on affected installations of Schneider Electric Struxureware Data Center Expert. Authentication is required to exploit this vulnerability.The specific flaw exists within the testRepository method. The issue results from the lack of proper validation of a user-supplied string before using it to execute a system call. An attacker can leverage this vulnerability to execute code in the context of root",
    "sources": [
      {
        "db": "ZDI",
        "id": "ZDI-21-1072"
      },
      {
        "db": "VULMON",
        "id": "CVE-2021-22795"
      }
    ],
    "trust": 0.72
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2021-22795",
        "trust": 1.4
      },
      {
        "db": "ZDI",
        "id": "ZDI-21-1072",
        "trust": 1.4
      },
      {
        "db": "ZDI_CAN",
        "id": "ZDI-CAN-13553",
        "trust": 0.7
      },
      {
        "db": "MCAFEE",
        "id": "SB20210",
        "trust": 0.6
      },
      {
        "db": "AUSCERT",
        "id": "ESB-2021.3095",
        "trust": 0.6
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-21-257-03",
        "trust": 0.6
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202109-989",
        "trust": 0.6
      },
      {
        "db": "VULMON",
        "id": "CVE-2021-22795",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202109-989"
      },
      {
        "db": "VULMON",
        "id": "CVE-2021-22795"
      },
      {
        "db": "ZDI",
        "id": "ZDI-21-1072"
      }
    ]
  },
  "id": "VAR-202109-1929",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "VARIoT devices database",
        "id": null
      }
    ],
    "trust": 0.1196509
  },
  "last_update_date": "2021-12-18T15:40:54.171000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "Schneider Electric has issued an update to correct this vulnerability.",
        "trust": 0.7,
        "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-257-03"
      },
      {
        "title": "Schneider Electric Struxureware Data Center Expert Fixes for operating system command injection vulnerabilities",
        "trust": 0.6,
        "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=162791"
      }
    ],
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202109-989"
      },
      {
        "db": "ZDI",
        "id": "ZDI-21-1072"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 1.3,
        "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-257-03"
      },
      {
        "trust": 0.7,
        "url": "https://www.zerodayinitiative.com/advisories/zdi-21-1072/"
      },
      {
        "trust": 0.6,
        "url": "https://www.cybersecurity-help.cz/vdb/sb2021091511"
      },
      {
        "trust": 0.6,
        "url": "https://www.auscert.org.au/bulletins/esb-2021.3095"
      }
    ],
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202109-989"
      },
      {
        "db": "VULMON",
        "id": "CVE-2021-22795"
      },
      {
        "db": "ZDI",
        "id": "ZDI-21-1072"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202109-989"
      },
      {
        "db": "VULMON",
        "id": "CVE-2021-22795"
      },
      {
        "db": "ZDI",
        "id": "ZDI-21-1072"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2021-09-14T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202109-989"
      },
      {
        "date": null,
        "db": "VULMON",
        "id": "CVE-2021-22795"
      },
      {
        "date": "2021-09-15T00:00:00",
        "db": "ZDI",
        "id": "ZDI-21-1072"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2021-09-16T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202109-989"
      },
      {
        "date": null,
        "db": "VULMON",
        "id": "CVE-2021-22795"
      },
      {
        "date": "2021-09-15T00:00:00",
        "db": "ZDI",
        "id": "ZDI-21-1072"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202109-989"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Schneider Electric Struxureware Data Center Expert Command Injection Remote Code Execution Vulnerability",
    "sources": [
      {
        "db": "ZDI",
        "id": "ZDI-21-1072"
      }
    ],
    "trust": 0.7
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "operating system commend injection",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202109-989"
      }
    ],
    "trust": 0.6
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.