VAR-202202-0243
Vulnerability from variot - Updated: 2023-12-18 11:56A CWE-862: Missing Authorization vulnerability exists that could cause information exposure when an attacker sends a specific message. Affected Product: Interactive Graphical SCADA System Data Server (V15.0.0.22020 and prior). This vulnerability allows remote attackers to disclose sensitive information on affected installations of Schneider Electric IGSS. Authentication is not required to exploit this vulnerability.The specific flaw exists within the IGSSDataServer process, which listens on TCP port 12401 by default. The issue results from the lack of authentication prior to allowing access to functionality. An attacker can leverage this vulnerability to disclose information from the IGSS application. Schneider Electric Interactive Graphical SCADA System (IGSS) is a set of SCADA (Data Acquisition and Supervisory Control System) systems used by Schneider Electric in France to monitor and control industrial processes
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202202-0243",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "interactive graphical scada system data server",
"scope": "lte",
"trust": 1.0,
"vendor": "schneider electric",
"version": "15.0.0.22020"
},
{
"model": "igss data server",
"scope": "eq",
"trust": 0.8,
"vendor": "schneider electric",
"version": null
},
{
"model": "igss data server",
"scope": "lte",
"trust": 0.8,
"vendor": "schneider electric",
"version": "15.0.0.22020 and earlier"
},
{
"model": "igss",
"scope": null,
"trust": 0.7,
"vendor": "schneider electric",
"version": null
},
{
"model": "electric interactive graphical scada system",
"scope": "lte",
"trust": 0.6,
"vendor": "schneider",
"version": "\u003c=15.0.0.22020"
}
],
"sources": [
{
"db": "ZDI",
"id": "ZDI-22-324"
},
{
"db": "CNVD",
"id": "CNVD-2022-13072"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-005333"
},
{
"db": "NVD",
"id": "CVE-2022-24317"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:a:schneider-electric:interactive_graphical_scada_system_data_server:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "15.0.0.22020",
"vulnerable": true
}
],
"operator": "OR"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2022-24317"
}
]
},
"credits": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/credits#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Vyacheslav Moskvin",
"sources": [
{
"db": "ZDI",
"id": "ZDI-22-324"
},
{
"db": "CNNVD",
"id": "CNNVD-202202-917"
}
],
"trust": 1.3
},
"cve": "CVE-2022-24317",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"acInsufInfo": false,
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "NVD",
"availabilityImpact": "NONE",
"baseScore": 5.0,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 10.0,
"impactScore": 2.9,
"integrityImpact": "NONE",
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "MEDIUM",
"trust": 1.0,
"userInteractionRequired": false,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
"version": "2.0"
},
{
"acInsufInfo": null,
"accessComplexity": "Low",
"accessVector": "Network",
"authentication": "None",
"author": "NVD",
"availabilityImpact": "None",
"baseScore": 5.0,
"confidentialityImpact": "Partial",
"exploitabilityScore": null,
"id": "CVE-2022-24317",
"impactScore": null,
"integrityImpact": "None",
"obtainAllPrivilege": null,
"obtainOtherPrivilege": null,
"obtainUserPrivilege": null,
"severity": "Medium",
"trust": 0.8,
"userInteractionRequired": null,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "NONE",
"baseScore": 5.0,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 10.0,
"id": "CNVD-2022-13072",
"impactScore": 2.9,
"integrityImpact": "NONE",
"severity": "MEDIUM",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "NVD",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 3.9,
"impactScore": 3.6,
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "None",
"baseScore": 7.5,
"baseSeverity": "High",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "CVE-2022-24317",
"impactScore": null,
"integrityImpact": "None",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.0"
},
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "ZDI",
"availabilityImpact": "NONE",
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"exploitabilityScore": 3.9,
"id": "CVE-2022-24317",
"impactScore": 1.4,
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 0.7,
"userInteraction": "NONE",
"vectorString": "AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
"version": "3.0"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2022-24317",
"trust": 1.8,
"value": "HIGH"
},
{
"author": "ZDI",
"id": "CVE-2022-24317",
"trust": 0.7,
"value": "MEDIUM"
},
{
"author": "CNVD",
"id": "CNVD-2022-13072",
"trust": 0.6,
"value": "MEDIUM"
},
{
"author": "CNNVD",
"id": "CNNVD-202202-917",
"trust": 0.6,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "ZDI",
"id": "ZDI-22-324"
},
{
"db": "CNVD",
"id": "CNVD-2022-13072"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-005333"
},
{
"db": "NVD",
"id": "CVE-2022-24317"
},
{
"db": "CNNVD",
"id": "CNNVD-202202-917"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "A CWE-862: Missing Authorization vulnerability exists that could cause information exposure when an attacker sends a specific message. Affected Product: Interactive Graphical SCADA System Data Server (V15.0.0.22020 and prior). This vulnerability allows remote attackers to disclose sensitive information on affected installations of Schneider Electric IGSS. Authentication is not required to exploit this vulnerability.The specific flaw exists within the IGSSDataServer process, which listens on TCP port 12401 by default. The issue results from the lack of authentication prior to allowing access to functionality. An attacker can leverage this vulnerability to disclose information from the IGSS application. Schneider Electric Interactive Graphical SCADA System (IGSS) is a set of SCADA (Data Acquisition and Supervisory Control System) systems used by Schneider Electric in France to monitor and control industrial processes",
"sources": [
{
"db": "NVD",
"id": "CVE-2022-24317"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-005333"
},
{
"db": "ZDI",
"id": "ZDI-22-324"
},
{
"db": "CNVD",
"id": "CNVD-2022-13072"
}
],
"trust": 2.79
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2022-24317",
"trust": 4.5
},
{
"db": "ZDI",
"id": "ZDI-22-324",
"trust": 3.1
},
{
"db": "SCHNEIDER",
"id": "SEVD-2022-039-01",
"trust": 2.2
},
{
"db": "ICS CERT",
"id": "ICSA-22-046-01",
"trust": 1.4
},
{
"db": "JVN",
"id": "JVNVU96061299",
"trust": 0.8
},
{
"db": "JVNDB",
"id": "JVNDB-2022-005333",
"trust": 0.8
},
{
"db": "ZDI_CAN",
"id": "ZDI-CAN-15193",
"trust": 0.7
},
{
"db": "CNVD",
"id": "CNVD-2022-13072",
"trust": 0.6
},
{
"db": "AUSCERT",
"id": "ESB-2022.0676",
"trust": 0.6
},
{
"db": "CS-HELP",
"id": "SB2022021405",
"trust": 0.6
},
{
"db": "CNNVD",
"id": "CNNVD-202202-917",
"trust": 0.6
}
],
"sources": [
{
"db": "ZDI",
"id": "ZDI-22-324"
},
{
"db": "CNVD",
"id": "CNVD-2022-13072"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-005333"
},
{
"db": "NVD",
"id": "CVE-2022-24317"
},
{
"db": "CNNVD",
"id": "CNNVD-202202-917"
}
]
},
"id": "VAR-202202-0243",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-13072"
}
],
"trust": 1.3829545300000001
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"ICS"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-13072"
}
]
},
"last_update_date": "2023-12-18T11:56:35.437000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "SEVD-2022-039-01",
"trust": 0.8,
"url": "https://download.schneider-electric.com/files?p_doc_ref=sevd-2022-039-01"
},
{
"title": "",
"trust": 0.7,
"url": "https://download.schneider-electric.com/files?p_doc_ref=sevd-2022-039-01https://www.cisa.gov/uscert/ics/advisories/icsa-22-046-01"
},
{
"title": "Patch for Schneider Electric Interactive Graphical SCADA System Authorization Issue Vulnerability",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchinfo/show/321161"
},
{
"title": "Schneider Electric Interactive Graphical SCADA System Security vulnerabilities",
"trust": 0.6,
"url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=182724"
}
],
"sources": [
{
"db": "ZDI",
"id": "ZDI-22-324"
},
{
"db": "CNVD",
"id": "CNVD-2022-13072"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-005333"
},
{
"db": "CNNVD",
"id": "CNNVD-202202-917"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-862",
"trust": 1.0
},
{
"problemtype": "Lack of authentication (CWE-862) [ others ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-005333"
},
{
"db": "NVD",
"id": "CVE-2022-24317"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 3.0,
"url": "https://www.zerodayinitiative.com/advisories/zdi-22-324/"
},
{
"trust": 2.2,
"url": "https://download.schneider-electric.com/files?p_doc_ref=sevd-2022-039-01"
},
{
"trust": 1.4,
"url": "https://nvd.nist.gov/vuln/detail/cve-2022-24317"
},
{
"trust": 0.8,
"url": "https://jvn.jp/vu/jvnvu96061299/"
},
{
"trust": 0.8,
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-22-046-01"
},
{
"trust": 0.7,
"url": "https://download.schneider-electric.com/files?p_doc_ref=sevd-2022-039-01https://www.cisa.gov/uscert/ics/advisories/icsa-22-046-01"
},
{
"trust": 0.6,
"url": "https://www.cybersecurity-help.cz/vdb/sb2022021405"
},
{
"trust": 0.6,
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-22-046-01"
},
{
"trust": 0.6,
"url": "https://www.auscert.org.au/bulletins/esb-2022.0676"
}
],
"sources": [
{
"db": "ZDI",
"id": "ZDI-22-324"
},
{
"db": "CNVD",
"id": "CNVD-2022-13072"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-005333"
},
{
"db": "NVD",
"id": "CVE-2022-24317"
},
{
"db": "CNNVD",
"id": "CNNVD-202202-917"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "ZDI",
"id": "ZDI-22-324"
},
{
"db": "CNVD",
"id": "CNVD-2022-13072"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-005333"
},
{
"db": "NVD",
"id": "CVE-2022-24317"
},
{
"db": "CNNVD",
"id": "CNNVD-202202-917"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2022-02-11T00:00:00",
"db": "ZDI",
"id": "ZDI-22-324"
},
{
"date": "2022-02-22T00:00:00",
"db": "CNVD",
"id": "CNVD-2022-13072"
},
{
"date": "2023-05-29T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2022-005333"
},
{
"date": "2022-02-09T23:15:19.990000",
"db": "NVD",
"id": "CVE-2022-24317"
},
{
"date": "2022-02-09T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202202-917"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2023-09-20T00:00:00",
"db": "ZDI",
"id": "ZDI-22-324"
},
{
"date": "2022-02-22T00:00:00",
"db": "CNVD",
"id": "CNVD-2022-13072"
},
{
"date": "2023-05-29T00:04:00",
"db": "JVNDB",
"id": "JVNDB-2022-005333"
},
{
"date": "2022-02-17T04:00:13.247000",
"db": "NVD",
"id": "CVE-2022-24317"
},
{
"date": "2022-03-10T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202202-917"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202202-917"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Interactive\u00a0Graphical\u00a0SCADA\u00a0System\u00a0Data\u00a0Server\u00a0 Vulnerability regarding lack of authentication in",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-005333"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "other",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202202-917"
}
],
"trust": 0.6
}
}
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.