A CWE-269: Improper Privilege Management vulnerability exists that could cause a local user to perform a denial of service through the console server service that is part of EcoStruxure Control Expert. Affected Products: EcoStruxure Control Expert (V15.1 and above). Schneider Electric of EcoStruxure Control Expert Exists in a permission management vulnerability.Service operation interruption (DoS) It may be in a state. This vulnerability is caused by improper rights management

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202304-1280",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ecostruxure control expert",
        "scope": "gte",
        "trust": 1.0,
        "vendor": "schneider electric",
        "version": "15.1"
      },
      {
        "model": "ecostruxure control expert",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "schneider electric",
        "version": "15.1  that\u0027s all"
      },
      {
        "model": "ecostruxure control expert",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "schneider electric",
        "version": null
      },
      {
        "model": "ecostruxure control expert",
        "scope": null,
        "trust": 0.8,
        "vendor": "schneider electric",
        "version": null
      },
      {
        "model": "electric ecostruxure control expert",
        "scope": "lte",
        "trust": 0.6,
        "vendor": "schneider",
        "version": "\u003c=15.1"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-40177"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-008916"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-1548"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "children": [],
            "cpe_match": [
              {
                "cpe23Uri": "cpe:2.3:a:schneider-electric:ecostruxure_control_expert:*:*:*:*:*:*:*:*",
                "cpe_name": [],
                "versionStartIncluding": "15.1",
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2023-1548"
      }
    ]
  },
  "cve": "CVE-2023-1548",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "LOCAL",
            "authentication": "SINGLE",
            "author": "CNVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 4.6,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 3.1,
            "id": "CNVD-2023-40177",
            "impactScore": 6.9,
            "integrityImpact": "NONE",
            "severity": "MEDIUM",
            "trust": 0.6,
            "vectorString": "AV:L/AC:L/Au:S/C:N/I:N/A:C",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "author": "NVD",
            "availabilityImpact": "HIGH",
            "baseScore": 5.5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 1.8,
            "impactScore": 3.6,
            "integrityImpact": "NONE",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "trust": 2.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Local",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 5.5,
            "baseSeverity": "Medium",
            "confidentialityImpact": "None",
            "exploitabilityScore": null,
            "id": "CVE-2023-1548",
            "impactScore": null,
            "integrityImpact": "None",
            "privilegesRequired": "Low",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "NVD",
            "id": "CVE-2023-1548",
            "trust": 1.8,
            "value": "MEDIUM"
          },
          {
            "author": "cybersecurity@se.com",
            "id": "CVE-2023-1548",
            "trust": 1.0,
            "value": "MEDIUM"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2023-40177",
            "trust": 0.6,
            "value": "MEDIUM"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202304-1427",
            "trust": 0.6,
            "value": "MEDIUM"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-40177"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-008916"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-1548"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-1548"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202304-1427"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "\nA CWE-269: Improper Privilege Management vulnerability exists that could cause a local user to\nperform a denial of service through the console server service that is part of EcoStruxure Control Expert. Affected Products:\u00a0EcoStruxure Control Expert (V15.1 and above). Schneider Electric of EcoStruxure Control Expert Exists in a permission management vulnerability.Service operation interruption (DoS) It may be in a state. This vulnerability is caused by improper rights management",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2023-1548"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-008916"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2023-40177"
      },
      {
        "db": "VULMON",
        "id": "CVE-2023-1548"
      }
    ],
    "trust": 2.25
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2023-1548",
        "trust": 3.9
      },
      {
        "db": "SCHNEIDER",
        "id": "SEVD-2023-101-03",
        "trust": 2.5
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-008916",
        "trust": 0.8
      },
      {
        "db": "CNVD",
        "id": "CNVD-2023-40177",
        "trust": 0.6
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202304-1427",
        "trust": 0.6
      },
      {
        "db": "VULMON",
        "id": "CVE-2023-1548",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-40177"
      },
      {
        "db": "VULMON",
        "id": "CVE-2023-1548"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-008916"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-1548"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202304-1427"
      }
    ]
  },
  "id": "VAR-202304-1280",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-40177"
      }
    ],
    "trust": 1.2287037
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "ICS"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-40177"
      }
    ]
  },
  "last_update_date": "2023-12-18T12:54:25.795000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "Patch for Schneider Electric EcoStruxure Control Expert Denial of Service Vulnerability",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchinfo/show/428641"
      },
      {
        "title": "Schneider Electric EcoStruxure Control Expert Security vulnerabilities",
        "trust": 0.6,
        "url": "http://123.124.177.30/web/xxk/bdxqbyid.tag?id=235097"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-40177"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202304-1427"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-269",
        "trust": 1.0
      },
      {
        "problemtype": "Improper authority management (CWE-269) [ others ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-008916"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-1548"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.4,
        "url": "https://download.schneider-electric.com/files?p_doc_ref=sevd-2023-101-03\u0026p_endoctype=security+and+safety+notice\u0026p_file_name=sevd-2023-101-03.pdf"
      },
      {
        "trust": 1.4,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2023-1548"
      },
      {
        "trust": 0.6,
        "url": "https://cxsecurity.com/cveshow/cve-2023-1548/"
      },
      {
        "trust": 0.1,
        "url": "https://cwe.mitre.org/data/definitions/269.html"
      },
      {
        "trust": 0.1,
        "url": "https://https://download.schneider-electric.com/files?p_doc_ref=sevd-2023-101-03\u0026p_endoctype=security+and+safety+notice\u0026p_file_name=sevd-2023-101-03.pdf"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-40177"
      },
      {
        "db": "VULMON",
        "id": "CVE-2023-1548"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-008916"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-1548"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202304-1427"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-40177"
      },
      {
        "db": "VULMON",
        "id": "CVE-2023-1548"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-008916"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-1548"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202304-1427"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2023-05-25T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2023-40177"
      },
      {
        "date": "2023-04-18T00:00:00",
        "db": "VULMON",
        "id": "CVE-2023-1548"
      },
      {
        "date": "2023-12-04T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2023-008916"
      },
      {
        "date": "2023-04-18T17:15:07.130000",
        "db": "NVD",
        "id": "CVE-2023-1548"
      },
      {
        "date": "2023-04-18T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202304-1427"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2023-05-24T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2023-40177"
      },
      {
        "date": "2023-04-18T00:00:00",
        "db": "VULMON",
        "id": "CVE-2023-1548"
      },
      {
        "date": "2023-12-04T04:49:00",
        "db": "JVNDB",
        "id": "JVNDB-2023-008916"
      },
      {
        "date": "2023-05-12T05:15:16.530000",
        "db": "NVD",
        "id": "CVE-2023-1548"
      },
      {
        "date": "2023-04-27T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202304-1427"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "local",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202304-1427"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Schneider\u00a0Electric\u00a0 of \u00a0EcoStruxure\u00a0Control\u00a0Expert\u00a0 Vulnerability in privilege management in",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-008916"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "other",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202304-1427"
      }
    ],
    "trust": 0.6
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading...

Loading...

Loading...

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.