var-202406-0183
Vulnerability from variot
A vulnerability has been identified in PowerSys (All versions < V3.11). The affected application insufficiently protects responses to authentication requests. This could allow a local attacker to bypass authentication, thereby gaining administrative privileges for the managed remote devices. PowerSys is a service program used for debugging, maintenance and diagnosis of PowerLink 50/100 or SWT 3000 devices
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202406-0183", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "powersys", "scope": "lt", "trust": 0.6, "vendor": "siemens", "version": "3.11" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-26702" } ] }, "cve": "CVE-2024-36266", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "LOCAL", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "COMPLETE", "baseScore": 7.2, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 3.9, "id": "CNVD-2024-26702", "impactScore": 10.0, "integrityImpact": "COMPLETE", "severity": "HIGH", "trust": 0.6, "vectorString": "AV:L/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "LOCAL", "author": "productcert@siemens.com", "availabilityImpact": "HIGH", "baseScore": 9.3, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.5, "impactScore": 6.0, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" } ], "severity": [ { "author": "productcert@siemens.com", "id": "CVE-2024-36266", "trust": 1.0, "value": "CRITICAL" }, { "author": "CNVD", "id": "CNVD-2024-26702", "trust": 0.6, "value": "HIGH" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-26702" }, { "db": "NVD", "id": "CVE-2024-36266" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "A vulnerability has been identified in PowerSys (All versions \u003c V3.11). The affected application insufficiently protects responses to authentication requests. This could allow a local attacker to bypass authentication, thereby gaining administrative privileges for the managed remote devices. PowerSys is a service program used for debugging, maintenance and diagnosis of PowerLink 50/100 or SWT 3000 devices", "sources": [ { "db": "NVD", "id": "CVE-2024-36266" }, { "db": "CNVD", "id": "CNVD-2024-26702" } ], "trust": 1.44 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "SIEMENS", "id": "SSA-024584", "trust": 1.6 }, { "db": "NVD", "id": "CVE-2024-36266", "trust": 1.6 }, { "db": "CNVD", "id": "CNVD-2024-26702", "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-26702" }, { "db": "NVD", "id": "CVE-2024-36266" } ] }, "id": "VAR-202406-0183", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2024-26702" } ], "trust": 0.06 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "ICS" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-26702" } ] }, "last_update_date": "2024-07-04T23:09:12.292000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Patch for Siemens PowerSys Authentication Error Vulnerability", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchinfo/show/555071" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-26702" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-287", "trust": 1.0 } ], "sources": [ { "db": "NVD", "id": "CVE-2024-36266" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.6, "url": "https://cert-portal.siemens.com/productcert/html/ssa-024584.html" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-26702" }, { "db": "NVD", "id": "CVE-2024-36266" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2024-26702" }, { "db": "NVD", "id": "CVE-2024-36266" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2024-06-11T00:00:00", "db": "CNVD", "id": "CNVD-2024-26702" }, { "date": "2024-06-11T12:15:18.657000", "db": "NVD", "id": "CVE-2024-36266" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2024-06-12T00:00:00", "db": "CNVD", "id": "CNVD-2024-26702" }, { "date": "2024-06-11T13:54:12.057000", "db": "NVD", "id": "CVE-2024-36266" } ] }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Siemens PowerSys Authentication Error Vulnerability", "sources": [ { "db": "CNVD", "id": "CNVD-2024-26702" } ], "trust": 0.6 } }
Loading...
Loading...
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.