cve-2024-36266
Vulnerability from cvelistv5
Published
2024-06-11 11:15
Modified
2024-08-02 03:37
Severity ?
9.3 (Critical) - CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H
8.5 (High) - CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:N/VC:N/VI:H/VA:N/SC:H/SI:H/SA:H
8.5 (High) - CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:N/VC:N/VI:H/VA:N/SC:H/SI:H/SA:H
EPSS score ?
Summary
A vulnerability has been identified in PowerSys (All versions < V3.11). The affected application insufficiently protects responses to authentication requests. This could allow a local attacker to bypass authentication, thereby gaining administrative privileges for the managed remote devices.
References
{ "containers": { "adp": [ { "affected": [ { "cpes": [ "cpe:2.3:a:siemens:powersys:v3.11:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "powersys", "vendor": "siemens", "versions": [ { "lessThan": "3.11", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2024-36266", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-06-11T13:11:44.819782Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-06-11T13:14:45.274Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" }, { "providerMetadata": { "dateUpdated": "2024-08-02T03:37:04.767Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/html/ssa-024584.html" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "PowerSys", "vendor": "Siemens", "versions": [ { "lessThan": "V3.11", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in PowerSys (All versions \u003c V3.11). The affected application insufficiently protects responses to authentication requests. This could allow a local attacker to bypass authentication, thereby gaining administrative privileges for the managed remote devices." } ], "metrics": [ { "cvssV3_1": { "baseScore": 9.3, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" } }, { "cvssV4_0": { "baseScore": 8.5, "baseSeverity": "HIGH", "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:N/VC:N/VI:H/VA:N/SC:H/SI:H/SA:H", "version": "4.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-287", "description": "CWE-287: Improper Authentication", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-06-11T14:20:59.711Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://cert-portal.siemens.com/productcert/html/ssa-024584.html" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2024-36266", "datePublished": "2024-06-11T11:15:59.201Z", "dateReserved": "2024-05-22T15:42:14.849Z", "dateUpdated": "2024-08-02T03:37:04.767Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2024-36266\",\"sourceIdentifier\":\"productcert@siemens.com\",\"published\":\"2024-06-11T12:15:18.657\",\"lastModified\":\"2024-06-11T13:54:12.057\",\"vulnStatus\":\"Awaiting Analysis\",\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability has been identified in PowerSys (All versions \u003c V3.11). The affected application insufficiently protects responses to authentication requests. This could allow a local attacker to bypass authentication, thereby gaining administrative privileges for the managed remote devices.\"},{\"lang\":\"es\",\"value\":\"Se ha identificado una vulnerabilidad en PowerSys (Todas las versiones \u0026lt; V3.11). La aplicaci\u00f3n afectada protege insuficientemente las respuestas a las solicitudes de autenticaci\u00f3n. Esto podr\u00eda permitir que un atacante local eluda la autenticaci\u00f3n y obtenga as\u00ed privilegios administrativos para los dispositivos remotos administrados.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"CHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\",\"baseScore\":9.3,\"baseSeverity\":\"CRITICAL\"},\"exploitabilityScore\":2.5,\"impactScore\":6.0}]},\"weaknesses\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-287\"}]}],\"references\":[{\"url\":\"https://cert-portal.siemens.com/productcert/html/ssa-024584.html\",\"source\":\"productcert@siemens.com\"}]}}" } }
Loading...
Loading...
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.