var-202101-0304
Vulnerability from variot

A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions < V5.2.5), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.5.0). The web server of the affected devices contains a vulnerability that may lead to a buffer overflow condition. An attacker could cause this condition on the webserver by sending a specially crafted request. The webserver could stop and not recover anymore. SCALANCE X-200 and SCALANCE X-200IRT An out-of-bounds write vulnerability exists in the switch family.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. SCALANCE X is a switch used to connect industrial components, such as programmable logic controllers (plc) or human machine interfaces (HMIs)

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202101-0304",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "scalance xc216eec",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xb216",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xc206-2g poe eec",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xc216",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance x308-2lh\\+",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance x307-3",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xc206-2sfp g eec",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance x307-3ld",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xc224",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance x308-2m",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xc208g",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance x202-2pirt",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.5.0"
      },
      {
        "model": "scalance xf204-2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xc208g poe",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xc206-2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance x308-2ld",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance x200-4pirt",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.5.0"
      },
      {
        "model": "scalance xf201-3p irt",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xc216-4c",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xf204irt",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xb205-3ld",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xp216poe eec",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xc224-4c g \\",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xf206-1",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xc216-4c g eec",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xc206-2sfp g",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xp208poe eec",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance x320-1fe",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xf204 dna",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xp208 \\",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xf204-2ba dna",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance x202-2irt",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.5.0"
      },
      {
        "model": "scalance x310fe",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xf208",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance x308-2lh",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xc206-2sfp",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance x310",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance x320-3ldfe",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xb213-3ld",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance x308-2",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xc224-4c g",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xc224-4c g eec",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance x202-2pirt siplus net",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.5.0"
      },
      {
        "model": "scalance x308-2m ts",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xf204-2ba irt",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xc208g \\",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xc216-4c g \\",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xp208",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xp216",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xc206-2sfp g \\",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance x201-3pirt",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.5.0"
      },
      {
        "model": "scalance xb208",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xp216 \\",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xf204",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xb205-3",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xp216eec",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xc206-2g poe",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xb213-3",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xp208eec",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xc208eec",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance x204irt",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.5.0"
      },
      {
        "model": "scalance xc216-4c g",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xf202-2p irt",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xc208",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xc206-2sfp eec",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xc208g eec",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance x200-4pirt",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance x307-3ld",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance x202-2pirt",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance x308-2",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "siplus net scalance x202-2pirt",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance x204irt",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance x307-3",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance x201-3pirt",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance x202-2irt",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance x308-2ld",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance x-200irt switch family",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance switch family",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "x-200"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-02594"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-015533"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-25226"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x200-4pirt_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.5.0",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x200-4pirt:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x201-3pirt_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.5.0",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x201-3pirt:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x202-2irt_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.5.0",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x202-2irt:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x202-2pirt_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.5.0",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x202-2pirt:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x202-2pirt_siplus_net_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.5.0",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x202-2pirt_siplus_net:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x204irt_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.5.0",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x204irt:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x307-3_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x307-3:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x307-3ld_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x307-3ld:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x308-2_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x308-2:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x308-2ld_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x308-2ld:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x308-2lh_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x308-2lh:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x308-2lh\\+_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x308-2lh\\+:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x308-2m_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x308-2m:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x308-2m_ts_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x308-2m_ts:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x310_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x310:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x310fe_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x310fe:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x320-1fe_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x320-1fe:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x320-3ldfe_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x320-3ldfe:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xb205-3_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xb205-3:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xb205-3ld_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xb205-3ld:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xb208_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xb208:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xb213-3_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xb213-3:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xb213-3ld_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xb213-3ld:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xb216_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xb216:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xc206-2_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xc206-2:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xc206-2g_poe__firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xc206-2g_poe_:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xc206-2g_poe_eec_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xc206-2g_poe_eec:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xc206-2sfp_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xc206-2sfp:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xc206-2sfp_eec_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xc206-2sfp_eec:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xc206-2sfp_g_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xc206-2sfp_g:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xc206-2sfp_g_\\(e\\/ip\\)_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xc206-2sfp_g_\\(e\\/ip\\):-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xc206-2sfp_g_eec_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xc206-2sfp_g_eec:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xc208_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xc208:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xc208eec_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xc208eec:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xc208g_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xc208g:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xc208g_\\(e\\/ip\\)_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xc208g_\\(e\\/ip\\):-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xc208g_eec_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xc208g_eec:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xc208g_poe_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xc208g_poe:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xc216_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xc216:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xc216-4c_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xc216-4c:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xc216-4c_g_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xc216-4c_g:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xc216-4c_g_\\(e\\/ip\\)_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xc216-4c_g_\\(e\\/ip\\):-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xc216-4c_g_eec_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xc216-4c_g_eec:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xc216eec_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xc216eec:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xc224-4c_g__firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xc224-4c_g_:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xc224-4c_g_\\(e\\/ip\\)_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xc224-4c_g_\\(e\\/ip\\):-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xc224-4c_g_eec_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xc224-4c_g_eec:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xc224__firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xc224_:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xf201-3p_irt_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xf201-3p_irt:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xf202-2p_irt_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xf202-2p_irt:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xf204_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xf204:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xf204-2_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xf204-2:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xf204-2ba_dna_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xf204-2ba_dna:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xf204-2ba_irt_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xf204-2ba_irt:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xf204_dna_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xf204_dna:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xf204irt_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xf204irt:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xf206-1_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xf206-1:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xf208_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xf208:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xp208_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xp208:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xp208_\\(eip\\)_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xp208_\\(eip\\):-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xp208eec_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xp208eec:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xp208poe_eec_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xp208poe_eec:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xp216_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xp216:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xp216_\\(eip\\)_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xp216_\\(eip\\):-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xp216eec_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xp216eec:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xp216poe_eec_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xp216poe_eec:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2020-25226"
      }
    ]
  },
  "credits": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/credits#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Siemens reported these vulnerabilities to CISA.",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202101-917"
      }
    ],
    "trust": 0.6
  },
  "cve": "CVE-2020-25226",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "acInsufInfo": false,
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "NVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 10.0,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 10.0,
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "severity": "HIGH",
            "trust": 1.0,
            "userInteractionRequired": false,
            "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
            "version": "2.0"
          },
          {
            "acInsufInfo": null,
            "accessComplexity": "Low",
            "accessVector": "Network",
            "authentication": "None",
            "author": "NVD",
            "availabilityImpact": "Complete",
            "baseScore": 10.0,
            "confidentialityImpact": "Complete",
            "exploitabilityScore": null,
            "id": "CVE-2020-25226",
            "impactScore": null,
            "integrityImpact": "Complete",
            "obtainAllPrivilege": null,
            "obtainOtherPrivilege": null,
            "obtainUserPrivilege": null,
            "severity": "High",
            "trust": 0.8,
            "userInteractionRequired": null,
            "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 7.8,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 10.0,
            "id": "CNVD-2021-02594",
            "impactScore": 6.9,
            "integrityImpact": "NONE",
            "severity": "HIGH",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "NVD",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 9.8,
            "baseSeverity": "Critical",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "CVE-2020-25226",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "NVD",
            "id": "CVE-2020-25226",
            "trust": 1.8,
            "value": "CRITICAL"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2021-02594",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202101-917",
            "trust": 0.6,
            "value": "CRITICAL"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-02594"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-015533"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-25226"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202101-917"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions \u003c V5.2.5), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions \u003c V5.5.0). The web server of the affected devices contains a vulnerability that may lead to a buffer overflow condition. An attacker could cause this condition on the webserver by sending a specially crafted request. The webserver could stop and not recover anymore. SCALANCE X-200 and SCALANCE X-200IRT An out-of-bounds write vulnerability exists in the switch family.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. SCALANCE X is a switch used to connect industrial components, such as programmable logic controllers (plc) or human machine interfaces (HMIs)",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2020-25226"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-015533"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2021-02594"
      }
    ],
    "trust": 2.16
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2020-25226",
        "trust": 3.0
      },
      {
        "db": "SIEMENS",
        "id": "SSA-139628",
        "trust": 2.2
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-015533",
        "trust": 0.8
      },
      {
        "db": "CNVD",
        "id": "CNVD-2021-02594",
        "trust": 0.6
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-21-012-05",
        "trust": 0.6
      },
      {
        "db": "AUSCERT",
        "id": "ESB-2021.0127",
        "trust": 0.6
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202101-917",
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-02594"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-015533"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-25226"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202101-917"
      }
    ]
  },
  "id": "VAR-202101-0304",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-02594"
      }
    ],
    "trust": 1.2646204777777776
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "ICS"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-02594"
      }
    ]
  },
  "last_update_date": "2023-12-18T11:57:47.734000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "SSA-139628",
        "trust": 0.8,
        "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-139628.pdf"
      },
      {
        "title": "Patch for Scalance X Products heap buffer overflow vulnerability (CNVD-2021-02594)",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchinfo/show/244018"
      },
      {
        "title": "Multiple Siemens Product Buffer Error Vulnerability Fix",
        "trust": 0.6,
        "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=139392"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-02594"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-015533"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202101-917"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-122",
        "trust": 1.0
      },
      {
        "problemtype": "Out-of-bounds writing (CWE-787) [NVD Evaluation ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-015533"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-25226"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.2,
        "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-139628.pdf"
      },
      {
        "trust": 1.4,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2020-25226"
      },
      {
        "trust": 0.6,
        "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-012-05"
      },
      {
        "trust": 0.6,
        "url": "https://www.auscert.org.au/bulletins/esb-2021.0127/"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-02594"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-015533"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-25226"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202101-917"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-02594"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-015533"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-25226"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202101-917"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2021-01-13T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2021-02594"
      },
      {
        "date": "2021-10-01T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2020-015533"
      },
      {
        "date": "2021-01-12T21:15:16.543000",
        "db": "NVD",
        "id": "CVE-2020-25226"
      },
      {
        "date": "2021-01-12T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202101-917"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2021-02-04T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2021-02594"
      },
      {
        "date": "2021-10-01T08:45:00",
        "db": "JVNDB",
        "id": "JVNDB-2020-015533"
      },
      {
        "date": "2022-07-28T17:13:46.093000",
        "db": "NVD",
        "id": "CVE-2020-25226"
      },
      {
        "date": "2021-09-15T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202101-917"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202101-917"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "SCALANCE\u00a0X-200\u00a0 and \u00a0SCALANCE\u00a0X-200IRT\u00a0 Out-of-bounds write vulnerability in switch family",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-015533"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "buffer error",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202101-917"
      }
    ],
    "trust": 0.6
  }
}

var-202101-0486
Vulnerability from variot

A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions < V5.2.5), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.5.0), SCALANCE X-200RNA switch family (All versions < V3.2.7). Devices create a new unique key upon factory reset, except when used with C-PLUG. When used with C-PLUG the devices use the hardcoded private RSA-key shipped with the firmware-image. An attacker could leverage this situation to a man-in-the-middle situation and decrypt previously captured traffic. SCALANCE X is a switch used to connect industrial components, such as programmable logic controllers (plc) or human machine interfaces (HMIs)

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202101-0486",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "scalance xc216eec",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xb216",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xc206-2g poe eec",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xc216",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance x308-2lh\\+",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance x307-3",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xc206-2sfp g eec",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance x307-3ld",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xc224",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance x308-2m",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xc208g",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance x202-2pirt",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.5.0"
      },
      {
        "model": "scalance xf204-2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xc208g poe",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xc206-2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance x308-2ld",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance x200-4pirt",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.5.0"
      },
      {
        "model": "scalance xf201-3p irt",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xc216-4c",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xf204irt",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xb205-3ld",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xp216poe eec",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xc224-4c g \\",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xf206-1",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xc216-4c g eec",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xc206-2sfp g",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xp208poe eec",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance x320-1fe",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xf204 dna",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xp208 \\",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xf204-2ba dna",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance x202-2irt",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.5.0"
      },
      {
        "model": "scalance x310fe",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xf208",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance x308-2lh",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xc206-2sfp",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance x310",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance x320-3ldfe",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xb213-3ld",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance x308-2",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xc224-4c g",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xc224-4c g eec",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance x202-2pirt siplus net",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.5.0"
      },
      {
        "model": "scalance x308-2m ts",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xf204-2ba irt",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xc208g \\",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xc216-4c g \\",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xp208",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xp216",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xc206-2sfp g \\",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance x201-3pirt",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.5.0"
      },
      {
        "model": "scalance xb208",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xp216 \\",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xf204",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xb205-3",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xp216eec",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xc206-2g poe",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xb213-3",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xp208eec",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xc208eec",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance x204irt",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.5.0"
      },
      {
        "model": "scalance xc216-4c g",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xf202-2p irt",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xc208",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xc206-2sfp eec",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xc208g eec",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance x200-4pirt",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance x307-3ld",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance x202-2pirt",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance x308-2",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "siplus net scalance x202-2pirt",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance x204irt",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance x307-3",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance x201-3pirt",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance x202-2irt",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance x308-2ld",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance x-200irt switch family",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance switch family",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "x-200"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-02593"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-015531"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-28391"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x200-4pirt_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.5.0",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x200-4pirt:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x201-3pirt_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.5.0",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x201-3pirt:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x202-2irt_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.5.0",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x202-2irt:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x202-2pirt_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.5.0",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x202-2pirt:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x202-2pirt_siplus_net_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.5.0",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x202-2pirt_siplus_net:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x204irt_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.5.0",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x204irt:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x307-3_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x307-3:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x307-3ld_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x307-3ld:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x308-2_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x308-2:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x308-2ld_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x308-2ld:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x308-2lh_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x308-2lh:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x308-2lh\\+_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x308-2lh\\+:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x308-2m_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x308-2m:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x308-2m_ts_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x308-2m_ts:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x310_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x310:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x310fe_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x310fe:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x320-1fe_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x320-1fe:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x320-3ldfe_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x320-3ldfe:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xb205-3_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xb205-3:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xb205-3ld_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xb205-3ld:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xb208_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xb208:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xb213-3_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xb213-3:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xb213-3ld_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xb213-3ld:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xb216_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xb216:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xc206-2_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xc206-2:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xc206-2g_poe__firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xc206-2g_poe_:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xc206-2g_poe_eec_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xc206-2g_poe_eec:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xc206-2sfp_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xc206-2sfp:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xc206-2sfp_eec_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xc206-2sfp_eec:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xc206-2sfp_g_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xc206-2sfp_g:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xc206-2sfp_g_\\(e\\/ip\\)_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xc206-2sfp_g_\\(e\\/ip\\):-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xc206-2sfp_g_eec_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xc206-2sfp_g_eec:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xc208_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xc208:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xc208eec_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xc208eec:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xc208g_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xc208g:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xc208g_\\(e\\/ip\\)_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xc208g_\\(e\\/ip\\):-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xc208g_eec_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xc208g_eec:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xc208g_poe_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xc208g_poe:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xc216_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xc216:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xc216-4c_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xc216-4c:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xc216-4c_g_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xc216-4c_g:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xc216-4c_g_\\(e\\/ip\\)_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xc216-4c_g_\\(e\\/ip\\):-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xc216-4c_g_eec_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xc216-4c_g_eec:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xc216eec_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xc216eec:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xc224-4c_g__firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xc224-4c_g_:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xc224-4c_g_\\(e\\/ip\\)_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xc224-4c_g_\\(e\\/ip\\):-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xc224-4c_g_eec_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xc224-4c_g_eec:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xc224__firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xc224_:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xf201-3p_irt_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xf201-3p_irt:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xf202-2p_irt_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xf202-2p_irt:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xf204_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xf204:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xf204-2_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xf204-2:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xf204-2ba_dna_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xf204-2ba_dna:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xf204-2ba_irt_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xf204-2ba_irt:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xf204_dna_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xf204_dna:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xf204irt_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xf204irt:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xf206-1_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xf206-1:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xf208_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xf208:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xp208_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xp208:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xp208_\\(eip\\)_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xp208_\\(eip\\):-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xp208eec_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xp208eec:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xp208poe_eec_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xp208poe_eec:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xp216_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xp216:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xp216_\\(eip\\)_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xp216_\\(eip\\):-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xp216eec_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xp216eec:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xp216poe_eec_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xp216poe_eec:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2020-28391"
      }
    ]
  },
  "credits": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/credits#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Siemens ProductCERT reported these vulnerabilities to CISA.",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202101-834"
      }
    ],
    "trust": 0.6
  },
  "cve": "CVE-2020-28391",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "acInsufInfo": false,
            "accessComplexity": "MEDIUM",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "NVD",
            "availabilityImpact": "NONE",
            "baseScore": 4.3,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 8.6,
            "impactScore": 2.9,
            "integrityImpact": "NONE",
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "severity": "MEDIUM",
            "trust": 1.0,
            "userInteractionRequired": false,
            "vectorString": "AV:N/AC:M/Au:N/C:P/I:N/A:N",
            "version": "2.0"
          },
          {
            "acInsufInfo": null,
            "accessComplexity": "Medium",
            "accessVector": "Network",
            "authentication": "None",
            "author": "NVD",
            "availabilityImpact": "None",
            "baseScore": 4.3,
            "confidentialityImpact": "Partial",
            "exploitabilityScore": null,
            "id": "CVE-2020-28391",
            "impactScore": null,
            "integrityImpact": "None",
            "obtainAllPrivilege": null,
            "obtainOtherPrivilege": null,
            "obtainUserPrivilege": null,
            "severity": "Medium",
            "trust": 0.9,
            "userInteractionRequired": null,
            "vectorString": "AV:N/AC:M/Au:N/C:P/I:N/A:N",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "NONE",
            "baseScore": 9.4,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 10.0,
            "id": "CNVD-2021-02593",
            "impactScore": 9.2,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:N",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "HIGH",
            "attackVector": "NETWORK",
            "author": "NVD",
            "availabilityImpact": "NONE",
            "baseScore": 5.9,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 2.2,
            "impactScore": 3.6,
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.1"
          },
          {
            "attackComplexity": "High",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "None",
            "baseScore": 5.9,
            "baseSeverity": "Medium",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "CVE-2020-28391",
            "impactScore": null,
            "integrityImpact": "None",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "NVD",
            "id": "CVE-2020-28391",
            "trust": 1.8,
            "value": "MEDIUM"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2021-02593",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202101-834",
            "trust": 0.6,
            "value": "MEDIUM"
          },
          {
            "author": "VULMON",
            "id": "CVE-2020-28391",
            "trust": 0.1,
            "value": "MEDIUM"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-02593"
      },
      {
        "db": "VULMON",
        "id": "CVE-2020-28391"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-015531"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-28391"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202101-834"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions \u003c V5.2.5), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions \u003c V5.5.0), SCALANCE X-200RNA switch family (All versions \u003c V3.2.7). Devices create a new unique key upon factory reset, except when used with C-PLUG. When used with C-PLUG the devices use the hardcoded private RSA-key shipped with the firmware-image. An attacker could leverage this situation to a man-in-the-middle situation and decrypt previously captured traffic. SCALANCE X is a switch used to connect industrial components, such as programmable logic controllers (plc) or human machine interfaces (HMIs)",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2020-28391"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-015531"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2021-02593"
      },
      {
        "db": "VULMON",
        "id": "CVE-2020-28391"
      }
    ],
    "trust": 2.25
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2020-28391",
        "trust": 3.1
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-21-012-02",
        "trust": 2.5
      },
      {
        "db": "SIEMENS",
        "id": "SSA-274900",
        "trust": 2.3
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-015531",
        "trust": 0.8
      },
      {
        "db": "CNVD",
        "id": "CNVD-2021-02593",
        "trust": 0.6
      },
      {
        "db": "AUSCERT",
        "id": "ESB-2021.0124",
        "trust": 0.6
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202101-834",
        "trust": 0.6
      },
      {
        "db": "VULMON",
        "id": "CVE-2020-28391",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-02593"
      },
      {
        "db": "VULMON",
        "id": "CVE-2020-28391"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-015531"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-28391"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202101-834"
      }
    ]
  },
  "id": "VAR-202101-0486",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-02593"
      }
    ],
    "trust": 1.2646204777777776
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "ICS"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-02593"
      }
    ]
  },
  "last_update_date": "2023-12-18T11:23:59.016000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "SSA-274900",
        "trust": 0.8,
        "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-274900.pdf"
      },
      {
        "title": "Patch for Scalance X Products hard-coded encryption key vulnerability",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchinfo/show/244015"
      },
      {
        "title": "Multiple Siemens Product security vulnerabilities",
        "trust": 0.6,
        "url": "http://123.124.177.30/web/xxk/bdxqbyid.tag?id=139506"
      },
      {
        "title": "Siemens Security Advisories: Siemens Security Advisory",
        "trust": 0.1,
        "url": "https://vulmon.com/vendoradvisory?qidtp=siemens_security_advisories\u0026qid=16f5b7ec974eee0b50172f47db7b7ec5"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-02593"
      },
      {
        "db": "VULMON",
        "id": "CVE-2020-28391"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-015531"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202101-834"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-321",
        "trust": 1.0
      },
      {
        "problemtype": "Using hardcoded credentials (CWE-798) [NVD Evaluation ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-015531"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-28391"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 3.1,
        "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-012-02"
      },
      {
        "trust": 2.3,
        "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-274900.pdf"
      },
      {
        "trust": 1.4,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2020-28391"
      },
      {
        "trust": 0.6,
        "url": "https://www.auscert.org.au/bulletins/esb-2021.0124/"
      },
      {
        "trust": 0.1,
        "url": "https://cwe.mitre.org/data/definitions/321.html"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov"
      },
      {
        "trust": 0.1,
        "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-012-02"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-02593"
      },
      {
        "db": "VULMON",
        "id": "CVE-2020-28391"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-015531"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-28391"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202101-834"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-02593"
      },
      {
        "db": "VULMON",
        "id": "CVE-2020-28391"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-015531"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-28391"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202101-834"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2021-01-13T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2021-02593"
      },
      {
        "date": "2021-01-12T00:00:00",
        "db": "VULMON",
        "id": "CVE-2020-28391"
      },
      {
        "date": "2021-10-01T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2020-015531"
      },
      {
        "date": "2021-01-12T21:15:18.120000",
        "db": "NVD",
        "id": "CVE-2020-28391"
      },
      {
        "date": "2021-01-12T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202101-834"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2021-02-04T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2021-02593"
      },
      {
        "date": "2022-12-13T00:00:00",
        "db": "VULMON",
        "id": "CVE-2020-28391"
      },
      {
        "date": "2021-10-01T08:04:00",
        "db": "JVNDB",
        "id": "JVNDB-2020-015531"
      },
      {
        "date": "2022-12-13T17:15:13.113000",
        "db": "NVD",
        "id": "CVE-2020-28391"
      },
      {
        "date": "2022-12-14T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202101-834"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202101-834"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "SCALANCE\u00a0X-200\u00a0 and \u00a0SCALANCE\u00a0X-200IRT\u00a0 Vulnerability in using hard-coded credentials in switch families",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-015531"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "trust management problem",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202101-834"
      }
    ],
    "trust": 0.6
  }
}

var-202204-0500
Vulnerability from variot

A vulnerability has been identified in SCALANCE X302-7 EEC (230V), SCALANCE X302-7 EEC (230V, coated), SCALANCE X302-7 EEC (24V), SCALANCE X302-7 EEC (24V, coated), SCALANCE X302-7 EEC (2x 230V), SCALANCE X302-7 EEC (2x 230V, coated), SCALANCE X302-7 EEC (2x 24V), SCALANCE X302-7 EEC (2x 24V, coated), SCALANCE X304-2FE, SCALANCE X306-1LD FE, SCALANCE X307-2 EEC (230V), SCALANCE X307-2 EEC (230V, coated), SCALANCE X307-2 EEC (24V), SCALANCE X307-2 EEC (24V, coated), SCALANCE X307-2 EEC (2x 230V), SCALANCE X307-2 EEC (2x 230V, coated), SCALANCE X307-2 EEC (2x 24V), SCALANCE X307-2 EEC (2x 24V, coated), SCALANCE X307-3, SCALANCE X307-3, SCALANCE X307-3LD, SCALANCE X307-3LD, SCALANCE X308-2, SCALANCE X308-2, SCALANCE X308-2LD, SCALANCE X308-2LD, SCALANCE X308-2LH, SCALANCE X308-2LH, SCALANCE X308-2LH+, SCALANCE X308-2LH+, SCALANCE X308-2M, SCALANCE X308-2M, SCALANCE X308-2M PoE, SCALANCE X308-2M PoE, SCALANCE X308-2M TS, SCALANCE X308-2M TS, SCALANCE X310, SCALANCE X310, SCALANCE X310FE, SCALANCE X310FE, SCALANCE X320-1 FE, SCALANCE X320-1-2LD FE, SCALANCE X408-2, SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M TS (24V), SCALANCE XR324-12M TS (24V), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M PoE (230V, ports on front), SCALANCE XR324-4M PoE (230V, ports on rear), SCALANCE XR324-4M PoE (24V, ports on front), SCALANCE XR324-4M PoE (24V, ports on rear), SCALANCE XR324-4M PoE TS (24V, ports on front), SIPLUS NET SCALANCE X308-2. The webserver of an affected device is missing specific security headers. This could allow an remote attacker to extract confidential session information under certain circumstances. plural SCALANCE The product contains a vulnerability related to the leakage of resources to the wrong area.Information may be obtained. SCALANCE X switches are used to connect industrial components such as programmable logic controllers (PLC) or human machine interfaces (HMI). SIPLUS extreme is designed for reliable operation under extreme conditions

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202204-0500",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "scalance xr324-4m eec",
        "scope": "lt",
        "trust": 1.6,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance xr324-4m poe",
        "scope": "lt",
        "trust": 1.6,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance xr324-4m poe ts",
        "scope": "lt",
        "trust": 1.6,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance xr324-12m",
        "scope": "lt",
        "trust": 1.6,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance xr324-12m ts",
        "scope": "lt",
        "trust": 1.6,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance x308-2m",
        "scope": "lt",
        "trust": 1.6,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance x307-3ld",
        "scope": "lt",
        "trust": 1.6,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance x304-2fe",
        "scope": "lt",
        "trust": 1.6,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance x310fe",
        "scope": "lt",
        "trust": 1.6,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance x308-2m ts",
        "scope": "lt",
        "trust": 1.6,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance x308-2ld",
        "scope": "lt",
        "trust": 1.6,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance x308-2lh",
        "scope": "lt",
        "trust": 1.6,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance x320-1fe",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance x307-3",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance x302-7eec",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance x320-1-2ldfe",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "siplus net scalance x308-2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance x408-2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance x308-2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance x306-1ldfe",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance x308-2m poe",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance x308-2lh\\+",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance x310",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance x307-2eec",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance x304-2fe",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance x307-3ld",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance x307-3",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance x308-2",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance x307-2eec",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance x308-2ld",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance x308-2lh+",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance x308-2lh",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance x306-1ldfe",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance x302-7eec",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance fe",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "x320-1\u003c4.1.4"
      },
      {
        "model": "scalance x320-1-2ld fe",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "x408-2\u003c4.1.4"
      },
      {
        "model": "siplus net scalance",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "x308-2\u003c4.1.4"
      },
      {
        "model": "scalance",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "x307-3\u003c4.1.4"
      },
      {
        "model": "scalance eec",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "x307-2\u003c4.1.4"
      },
      {
        "model": "scalance x306-1ld fe",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance eec",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "x302-7\u003c4.1.4"
      },
      {
        "model": "scalance",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "x310\u003c4.1.4"
      },
      {
        "model": "scalance x308-2m poe",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "x308-2\u003c4.1.4"
      },
      {
        "model": "scalance x308-2lh+",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.1.4"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-28482"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-001594"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-25755"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x302-7eec_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x302-7eec:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x304-2fe_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x304-2fe:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x306-1ldfe_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x306-1ldfe:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x307-2eec_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x307-2eec:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x307-3_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x307-3:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x307-3ld_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x307-3ld:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x308-2_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x308-2:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x308-2ld_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x308-2ld:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x308-2lh_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x308-2lh:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x308-2lh\\+_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x308-2lh\\+:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x308-2m_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x308-2m:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x308-2m_poe_firmware:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x308-2m_poe:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x308-2m_ts_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x308-2m_ts:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x310_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x310:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x310fe_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x310fe:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x320-1fe_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x320-1fe:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x320-1-2ldfe_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x320-1-2ldfe:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x408-2_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x408-2:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xr324-4m_eec_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xr324-4m_eec:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xr324-4m_poe_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xr324-4m_poe:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xr324-4m_poe_ts_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xr324-4m_poe_ts:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xr324-12m_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xr324-12m:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xr324-12m_ts_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xr324-12m_ts:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:siplus_net_scalance_x308-2_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:siplus_net_scalance_x308-2:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2022-25755"
      }
    ]
  },
  "credits": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/credits#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Michael Messner and Abian Blome of Siemens Energy coordinated the disclosure of CVE-2022-25751 and CVE-2022-25756 to CISA.",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202204-3138"
      }
    ],
    "trust": 0.6
  },
  "cve": "CVE-2022-25755",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "acInsufInfo": false,
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "NVD",
            "availabilityImpact": "NONE",
            "baseScore": 5.0,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "impactScore": 2.9,
            "integrityImpact": "NONE",
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "severity": "MEDIUM",
            "trust": 1.0,
            "userInteractionRequired": false,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
            "version": "2.0"
          },
          {
            "acInsufInfo": null,
            "accessComplexity": "Low",
            "accessVector": "Network",
            "authentication": "None",
            "author": "NVD",
            "availabilityImpact": "None",
            "baseScore": 5.0,
            "confidentialityImpact": "Partial",
            "exploitabilityScore": null,
            "id": "CVE-2022-25755",
            "impactScore": null,
            "integrityImpact": "None",
            "obtainAllPrivilege": null,
            "obtainOtherPrivilege": null,
            "obtainUserPrivilege": null,
            "severity": "Medium",
            "trust": 0.9,
            "userInteractionRequired": null,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
            "version": "2.0"
          },
          {
            "accessComplexity": "HIGH",
            "accessVector": "ADJACENT_NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "NONE",
            "baseScore": 1.8,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 3.2,
            "id": "CNVD-2022-28482",
            "impactScore": 2.9,
            "integrityImpact": "NONE",
            "severity": "LOW",
            "trust": 0.6,
            "vectorString": "AV:A/AC:H/Au:N/C:P/I:N/A:N",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "NVD",
            "availabilityImpact": "NONE",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "impactScore": 3.6,
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "None",
            "baseScore": 7.5,
            "baseSeverity": "High",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "CVE-2022-25755",
            "impactScore": null,
            "integrityImpact": "None",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "NVD",
            "id": "CVE-2022-25755",
            "trust": 1.8,
            "value": "HIGH"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2022-28482",
            "trust": 0.6,
            "value": "LOW"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202204-3138",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "VULMON",
            "id": "CVE-2022-25755",
            "trust": 0.1,
            "value": "MEDIUM"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-28482"
      },
      {
        "db": "VULMON",
        "id": "CVE-2022-25755"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-001594"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-25755"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202204-3138"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "A vulnerability has been identified in SCALANCE X302-7 EEC (230V), SCALANCE X302-7 EEC (230V, coated), SCALANCE X302-7 EEC (24V), SCALANCE X302-7 EEC (24V, coated), SCALANCE X302-7 EEC (2x 230V), SCALANCE X302-7 EEC (2x 230V, coated), SCALANCE X302-7 EEC (2x 24V), SCALANCE X302-7 EEC (2x 24V, coated), SCALANCE X304-2FE, SCALANCE X306-1LD FE, SCALANCE X307-2 EEC (230V), SCALANCE X307-2 EEC (230V, coated), SCALANCE X307-2 EEC (24V), SCALANCE X307-2 EEC (24V, coated), SCALANCE X307-2 EEC (2x 230V), SCALANCE X307-2 EEC (2x 230V, coated), SCALANCE X307-2 EEC (2x 24V), SCALANCE X307-2 EEC (2x 24V, coated), SCALANCE X307-3, SCALANCE X307-3, SCALANCE X307-3LD, SCALANCE X307-3LD, SCALANCE X308-2, SCALANCE X308-2, SCALANCE X308-2LD, SCALANCE X308-2LD, SCALANCE X308-2LH, SCALANCE X308-2LH, SCALANCE X308-2LH+, SCALANCE X308-2LH+, SCALANCE X308-2M, SCALANCE X308-2M, SCALANCE X308-2M PoE, SCALANCE X308-2M PoE, SCALANCE X308-2M TS, SCALANCE X308-2M TS, SCALANCE X310, SCALANCE X310, SCALANCE X310FE, SCALANCE X310FE, SCALANCE X320-1 FE, SCALANCE X320-1-2LD FE, SCALANCE X408-2, SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M TS (24V), SCALANCE XR324-12M TS (24V), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M PoE (230V, ports on front), SCALANCE XR324-4M PoE (230V, ports on rear), SCALANCE XR324-4M PoE (24V, ports on front), SCALANCE XR324-4M PoE (24V, ports on rear), SCALANCE XR324-4M PoE TS (24V, ports on front), SIPLUS NET SCALANCE X308-2. The webserver of an affected device is missing specific security headers. This could allow an remote attacker to extract confidential session information under certain circumstances. plural  SCALANCE The product contains a vulnerability related to the leakage of resources to the wrong area.Information may be obtained. SCALANCE X switches are used to connect industrial components such as programmable logic controllers (PLC) or human machine interfaces (HMI). SIPLUS extreme is designed for reliable operation under extreme conditions",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2022-25755"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-001594"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2022-28482"
      },
      {
        "db": "VULMON",
        "id": "CVE-2022-25755"
      }
    ],
    "trust": 2.25
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2022-25755",
        "trust": 3.9
      },
      {
        "db": "SIEMENS",
        "id": "SSA-836527",
        "trust": 2.3
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-22-104-09",
        "trust": 1.5
      },
      {
        "db": "JVN",
        "id": "JVNVU91165555",
        "trust": 0.8
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-001594",
        "trust": 0.8
      },
      {
        "db": "CNVD",
        "id": "CNVD-2022-28482",
        "trust": 0.6
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202204-3138",
        "trust": 0.6
      },
      {
        "db": "VULMON",
        "id": "CVE-2022-25755",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-28482"
      },
      {
        "db": "VULMON",
        "id": "CVE-2022-25755"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-001594"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-25755"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202204-3138"
      }
    ]
  },
  "id": "VAR-202204-0500",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-28482"
      }
    ],
    "trust": 1.2919426426666667
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "ICS"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-28482"
      }
    ]
  },
  "last_update_date": "2023-12-18T11:56:15.042000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "SSA-836527",
        "trust": 0.8,
        "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-836527.pdf"
      },
      {
        "title": "Patch for Siemens SCALANCE X-300 Switch Family Devices Access Control Error Vulnerability",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchinfo/show/329321"
      },
      {
        "title": "Siemens SCALANCE Security vulnerabilities",
        "trust": 0.6,
        "url": "http://123.124.177.30/web/xxk/bdxqbyid.tag?id=245132"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-28482"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-001594"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202204-3138"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "NVD-CWE-Other",
        "trust": 1.0
      },
      {
        "problemtype": "Leakage of resources to the wrong area (CWE-668) [NVD Evaluation ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-001594"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-25755"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.3,
        "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-836527.pdf"
      },
      {
        "trust": 0.9,
        "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-104-09"
      },
      {
        "trust": 0.8,
        "url": "https://jvn.jp/vu/jvnvu91165555/"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2022-25755"
      },
      {
        "trust": 0.6,
        "url": "https://cxsecurity.com/cveshow/cve-2022-25755/"
      },
      {
        "trust": 0.6,
        "url": "https://us-cert.cisa.gov/ics/advisories/icsa-22-104-09"
      },
      {
        "trust": 0.1,
        "url": "https://cwe.mitre.org/data/definitions/668.html"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-28482"
      },
      {
        "db": "VULMON",
        "id": "CVE-2022-25755"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-001594"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-25755"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202204-3138"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-28482"
      },
      {
        "db": "VULMON",
        "id": "CVE-2022-25755"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-001594"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-25755"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202204-3138"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2022-04-13T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2022-28482"
      },
      {
        "date": "2022-04-12T00:00:00",
        "db": "VULMON",
        "id": "CVE-2022-25755"
      },
      {
        "date": "2022-04-26T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2022-001594"
      },
      {
        "date": "2022-04-12T09:15:14.793000",
        "db": "NVD",
        "id": "CVE-2022-25755"
      },
      {
        "date": "2022-04-12T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202204-3138"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2022-04-13T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2022-28482"
      },
      {
        "date": "2022-04-19T00:00:00",
        "db": "VULMON",
        "id": "CVE-2022-25755"
      },
      {
        "date": "2022-04-26T08:58:00",
        "db": "JVNDB",
        "id": "JVNDB-2022-001594"
      },
      {
        "date": "2023-07-10T19:40:16.493000",
        "db": "NVD",
        "id": "CVE-2022-25755"
      },
      {
        "date": "2023-07-11T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202204-3138"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202204-3138"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "plural \u00a0SCALANCE\u00a0 Vulnerability in leaking resources to the wrong area in the product",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-001594"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "other",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202204-3138"
      }
    ],
    "trust": 0.6
  }
}

var-202204-0494
Vulnerability from variot

A vulnerability has been identified in SCALANCE X302-7 EEC (230V), SCALANCE X302-7 EEC (230V, coated), SCALANCE X302-7 EEC (24V), SCALANCE X302-7 EEC (24V, coated), SCALANCE X302-7 EEC (2x 230V), SCALANCE X302-7 EEC (2x 230V, coated), SCALANCE X302-7 EEC (2x 24V), SCALANCE X302-7 EEC (2x 24V, coated), SCALANCE X304-2FE, SCALANCE X306-1LD FE, SCALANCE X307-2 EEC (230V), SCALANCE X307-2 EEC (230V, coated), SCALANCE X307-2 EEC (24V), SCALANCE X307-2 EEC (24V, coated), SCALANCE X307-2 EEC (2x 230V), SCALANCE X307-2 EEC (2x 230V, coated), SCALANCE X307-2 EEC (2x 24V), SCALANCE X307-2 EEC (2x 24V, coated), SCALANCE X307-3, SCALANCE X307-3, SCALANCE X307-3LD, SCALANCE X307-3LD, SCALANCE X308-2, SCALANCE X308-2, SCALANCE X308-2LD, SCALANCE X308-2LD, SCALANCE X308-2LH, SCALANCE X308-2LH, SCALANCE X308-2LH+, SCALANCE X308-2LH+, SCALANCE X308-2M, SCALANCE X308-2M, SCALANCE X308-2M PoE, SCALANCE X308-2M PoE, SCALANCE X308-2M TS, SCALANCE X308-2M TS, SCALANCE X310, SCALANCE X310, SCALANCE X310FE, SCALANCE X310FE, SCALANCE X320-1 FE, SCALANCE X320-1-2LD FE, SCALANCE X408-2, SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M TS (24V), SCALANCE XR324-12M TS (24V), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M PoE (230V, ports on front), SCALANCE XR324-4M PoE (230V, ports on rear), SCALANCE XR324-4M PoE (24V, ports on front), SCALANCE XR324-4M PoE (24V, ports on rear), SCALANCE XR324-4M PoE TS (24V, ports on front), SIPLUS NET SCALANCE X308-2. Affected devices do not properly validate the URI of incoming HTTP GET requests. This could allow an unauthenticated remote attacker to crash affected devices. SCALANCE X302-7EEC firmware, SCALANCE X304-2FE firmware, SCALANCE X306-1LDFE Multiple Siemens products, such as firmware, contain a classic buffer overflow vulnerability.Service operation interruption (DoS) It may be in a state. SCALANCE X switches are used to connect industrial components such as programmable logic controllers (PLC) or human machine interfaces (HMI). SIPLUS extreme is designed for reliable operation under extreme conditions.

A buffer overflow vulnerability exists in Siemens SCALANCE X-300 Switch Family Devices that could allow attackers to crash the device

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202204-0494",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "scalance xr324-4m eec",
        "scope": "lt",
        "trust": 1.6,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance xr324-4m poe",
        "scope": "lt",
        "trust": 1.6,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance xr324-4m poe ts",
        "scope": "lt",
        "trust": 1.6,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance xr324-12m",
        "scope": "lt",
        "trust": 1.6,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance xr324-12m ts",
        "scope": "lt",
        "trust": 1.6,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance x308-2m",
        "scope": "lt",
        "trust": 1.6,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance x307-3ld",
        "scope": "lt",
        "trust": 1.6,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance x304-2fe",
        "scope": "lt",
        "trust": 1.6,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance x310fe",
        "scope": "lt",
        "trust": 1.6,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance x308-2m ts",
        "scope": "lt",
        "trust": 1.6,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance x308-2ld",
        "scope": "lt",
        "trust": 1.6,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance x308-2lh",
        "scope": "lt",
        "trust": 1.6,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance x320-1fe",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance x307-3",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance x302-7eec",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance x320-1-2ldfe",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "siplus net scalance x308-2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance x408-2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance x308-2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance x306-1ldfe",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance x308-2m poe",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance x308-2lh\\+",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance x310",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance x307-2eec",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance x308-2lh",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance x308-2m",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance x408-2",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance x304-2fe",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance x308-2ld",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance x310fe",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance x308-2lh+",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance x306-1ldfe",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance xr324-4m eec",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance x308-2m ts",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance x302-7eec",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance x320-1fe",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance x307-3",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance x307-3ld",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance x320-1-2ldfe",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance x310",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance x308-2m poe",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance x308-2",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance xr324-4m poe",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance x307-2eec",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance fe",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "x320-1\u003c4.1.4"
      },
      {
        "model": "scalance x320-1-2ld fe",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "x408-2\u003c4.1.4"
      },
      {
        "model": "siplus net scalance",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "x308-2\u003c4.1.4"
      },
      {
        "model": "scalance",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "x307-3\u003c4.1.4"
      },
      {
        "model": "scalance eec",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "x307-2\u003c4.1.4"
      },
      {
        "model": "scalance x306-1ld fe",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance eec",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "x302-7\u003c4.1.4"
      },
      {
        "model": "scalance",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "x310\u003c4.1.4"
      },
      {
        "model": "scalance x308-2m poe",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "x308-2\u003c4.1.4"
      },
      {
        "model": "scalance x308-2lh+",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.1.4"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-28479"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-008106"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-26335"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x302-7eec_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x302-7eec:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x304-2fe_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x304-2fe:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x306-1ldfe_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x306-1ldfe:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x307-2eec_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x307-2eec:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x307-3_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x307-3:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x307-3ld_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x307-3ld:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x308-2_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x308-2:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x308-2ld_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x308-2ld:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x308-2lh_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x308-2lh:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x308-2lh\\+_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x308-2lh\\+:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x308-2m_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x308-2m:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x308-2m_poe_firmware:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x308-2m_poe:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x308-2m_ts_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x308-2m_ts:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x310_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x310:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x310fe_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x310fe:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x320-1fe_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x320-1fe:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x320-1-2ldfe_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x320-1-2ldfe:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x408-2_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x408-2:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xr324-4m_eec_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xr324-4m_eec:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xr324-4m_poe_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xr324-4m_poe:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xr324-4m_poe_ts_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xr324-4m_poe_ts:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xr324-12m_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xr324-12m:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xr324-12m_ts_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xr324-12m_ts:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:siplus_net_scalance_x308-2_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:siplus_net_scalance_x308-2:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2022-26335"
      }
    ]
  },
  "credits": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/credits#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Michael Messner and Abian Blome of Siemens Energy coordinated the disclosure of CVE-2022-25751 and CVE-2022-25756 to CISA.",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202204-3134"
      }
    ],
    "trust": 0.6
  },
  "cve": "CVE-2022-26335",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "acInsufInfo": false,
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "NVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 7.8,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 10.0,
            "impactScore": 6.9,
            "integrityImpact": "NONE",
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "severity": "HIGH",
            "trust": 1.0,
            "userInteractionRequired": false,
            "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
            "version": "2.0"
          },
          {
            "acInsufInfo": null,
            "accessComplexity": "Low",
            "accessVector": "Network",
            "authentication": "None",
            "author": "NVD",
            "availabilityImpact": "Complete",
            "baseScore": 7.8,
            "confidentialityImpact": "None",
            "exploitabilityScore": null,
            "id": "CVE-2022-26335",
            "impactScore": null,
            "integrityImpact": "None",
            "obtainAllPrivilege": null,
            "obtainOtherPrivilege": null,
            "obtainUserPrivilege": null,
            "severity": "High",
            "trust": 0.9,
            "userInteractionRequired": null,
            "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "ADJACENT_NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 8.3,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 6.5,
            "id": "CNVD-2022-28479",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 0.6,
            "vectorString": "AV:A/AC:L/Au:N/C:C/I:C/A:C",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "NVD",
            "availabilityImpact": "HIGH",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 3.9,
            "impactScore": 3.6,
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 7.5,
            "baseSeverity": "High",
            "confidentialityImpact": "None",
            "exploitabilityScore": null,
            "id": "CVE-2022-26335",
            "impactScore": null,
            "integrityImpact": "None",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "NVD",
            "id": "CVE-2022-26335",
            "trust": 1.8,
            "value": "HIGH"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2022-28479",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202204-3134",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "VULMON",
            "id": "CVE-2022-26335",
            "trust": 0.1,
            "value": "HIGH"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-28479"
      },
      {
        "db": "VULMON",
        "id": "CVE-2022-26335"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-008106"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-26335"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202204-3134"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "A vulnerability has been identified in SCALANCE X302-7 EEC (230V), SCALANCE X302-7 EEC (230V, coated), SCALANCE X302-7 EEC (24V), SCALANCE X302-7 EEC (24V, coated), SCALANCE X302-7 EEC (2x 230V), SCALANCE X302-7 EEC (2x 230V, coated), SCALANCE X302-7 EEC (2x 24V), SCALANCE X302-7 EEC (2x 24V, coated), SCALANCE X304-2FE, SCALANCE X306-1LD FE, SCALANCE X307-2 EEC (230V), SCALANCE X307-2 EEC (230V, coated), SCALANCE X307-2 EEC (24V), SCALANCE X307-2 EEC (24V, coated), SCALANCE X307-2 EEC (2x 230V), SCALANCE X307-2 EEC (2x 230V, coated), SCALANCE X307-2 EEC (2x 24V), SCALANCE X307-2 EEC (2x 24V, coated), SCALANCE X307-3, SCALANCE X307-3, SCALANCE X307-3LD, SCALANCE X307-3LD, SCALANCE X308-2, SCALANCE X308-2, SCALANCE X308-2LD, SCALANCE X308-2LD, SCALANCE X308-2LH, SCALANCE X308-2LH, SCALANCE X308-2LH+, SCALANCE X308-2LH+, SCALANCE X308-2M, SCALANCE X308-2M, SCALANCE X308-2M PoE, SCALANCE X308-2M PoE, SCALANCE X308-2M TS, SCALANCE X308-2M TS, SCALANCE X310, SCALANCE X310, SCALANCE X310FE, SCALANCE X310FE, SCALANCE X320-1 FE, SCALANCE X320-1-2LD FE, SCALANCE X408-2, SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M TS (24V), SCALANCE XR324-12M TS (24V), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M PoE (230V, ports on front), SCALANCE XR324-4M PoE (230V, ports on rear), SCALANCE XR324-4M PoE (24V, ports on front), SCALANCE XR324-4M PoE (24V, ports on rear), SCALANCE XR324-4M PoE TS (24V, ports on front), SIPLUS NET SCALANCE X308-2. Affected devices do not properly validate the URI of incoming HTTP GET requests. This could allow an unauthenticated remote attacker to crash affected devices. SCALANCE X302-7EEC firmware, SCALANCE X304-2FE firmware, SCALANCE X306-1LDFE Multiple Siemens products, such as firmware, contain a classic buffer overflow vulnerability.Service operation interruption (DoS) It may be in a state. SCALANCE X switches are used to connect industrial components such as programmable logic controllers (PLC) or human machine interfaces (HMI). SIPLUS extreme is designed for reliable operation under extreme conditions. \n\r\n\r\nA buffer overflow vulnerability exists in Siemens SCALANCE X-300 Switch Family Devices that could allow attackers to crash the device",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2022-26335"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-008106"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2022-28479"
      },
      {
        "db": "VULMON",
        "id": "CVE-2022-26335"
      }
    ],
    "trust": 2.25
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2022-26335",
        "trust": 3.9
      },
      {
        "db": "SIEMENS",
        "id": "SSA-836527",
        "trust": 3.1
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-22-104-09",
        "trust": 1.5
      },
      {
        "db": "JVN",
        "id": "JVNVU91165555",
        "trust": 0.8
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-008106",
        "trust": 0.8
      },
      {
        "db": "CNVD",
        "id": "CNVD-2022-28479",
        "trust": 0.6
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202204-3134",
        "trust": 0.6
      },
      {
        "db": "VULMON",
        "id": "CVE-2022-26335",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-28479"
      },
      {
        "db": "VULMON",
        "id": "CVE-2022-26335"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-008106"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-26335"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202204-3134"
      }
    ]
  },
  "id": "VAR-202204-0494",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-28479"
      }
    ],
    "trust": 1.2919426426666667
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "ICS"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-28479"
      }
    ]
  },
  "last_update_date": "2023-12-18T11:56:14.981000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "Patch for Siemens SCALANCE X-300 Switch Family Devices Buffer Overflow Vulnerability (CNVD-2022-28479)",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchinfo/show/329341"
      },
      {
        "title": "Multiple  Siemens Product security vulnerabilities",
        "trust": 0.6,
        "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=190125"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-28479"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202204-3134"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-120",
        "trust": 1.0
      },
      {
        "problemtype": "Classic buffer overflow (CWE-120) [NVD evaluation ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-008106"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-26335"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 3.1,
        "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-836527.pdf"
      },
      {
        "trust": 0.8,
        "url": "https://jvn.jp/vu/jvnvu91165555/"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2022-26335"
      },
      {
        "trust": 0.8,
        "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-22-104-09"
      },
      {
        "trust": 0.6,
        "url": "https://cxsecurity.com/cveshow/cve-2022-26335/"
      },
      {
        "trust": 0.6,
        "url": "https://us-cert.cisa.gov/ics/advisories/icsa-22-104-09"
      },
      {
        "trust": 0.1,
        "url": "https://cwe.mitre.org/data/definitions/120.html"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov"
      },
      {
        "trust": 0.1,
        "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-104-09"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-28479"
      },
      {
        "db": "VULMON",
        "id": "CVE-2022-26335"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-008106"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-26335"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202204-3134"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-28479"
      },
      {
        "db": "VULMON",
        "id": "CVE-2022-26335"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-008106"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-26335"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202204-3134"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2022-04-13T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2022-28479"
      },
      {
        "date": "2022-04-12T00:00:00",
        "db": "VULMON",
        "id": "CVE-2022-26335"
      },
      {
        "date": "2023-07-24T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2022-008106"
      },
      {
        "date": "2022-04-12T09:15:14.923000",
        "db": "NVD",
        "id": "CVE-2022-26335"
      },
      {
        "date": "2022-04-12T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202204-3134"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2022-04-13T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2022-28479"
      },
      {
        "date": "2022-04-19T00:00:00",
        "db": "VULMON",
        "id": "CVE-2022-26335"
      },
      {
        "date": "2023-07-24T08:22:00",
        "db": "JVNDB",
        "id": "JVNDB-2022-008106"
      },
      {
        "date": "2022-04-19T18:12:46.203000",
        "db": "NVD",
        "id": "CVE-2022-26335"
      },
      {
        "date": "2022-04-20T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202204-3134"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202204-3134"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Classic buffer overflow vulnerability in multiple Siemens products",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-008106"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "other",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202204-3134"
      }
    ],
    "trust": 0.6
  }
}

var-202204-0495
Vulnerability from variot

A vulnerability has been identified in SCALANCE X302-7 EEC (230V), SCALANCE X302-7 EEC (230V, coated), SCALANCE X302-7 EEC (24V), SCALANCE X302-7 EEC (24V, coated), SCALANCE X302-7 EEC (2x 230V), SCALANCE X302-7 EEC (2x 230V, coated), SCALANCE X302-7 EEC (2x 24V), SCALANCE X302-7 EEC (2x 24V, coated), SCALANCE X304-2FE, SCALANCE X306-1LD FE, SCALANCE X307-2 EEC (230V), SCALANCE X307-2 EEC (230V, coated), SCALANCE X307-2 EEC (24V), SCALANCE X307-2 EEC (24V, coated), SCALANCE X307-2 EEC (2x 230V), SCALANCE X307-2 EEC (2x 230V, coated), SCALANCE X307-2 EEC (2x 24V), SCALANCE X307-2 EEC (2x 24V, coated), SCALANCE X307-3, SCALANCE X307-3, SCALANCE X307-3LD, SCALANCE X307-3LD, SCALANCE X308-2, SCALANCE X308-2, SCALANCE X308-2LD, SCALANCE X308-2LD, SCALANCE X308-2LH, SCALANCE X308-2LH, SCALANCE X308-2LH+, SCALANCE X308-2LH+, SCALANCE X308-2M, SCALANCE X308-2M, SCALANCE X308-2M PoE, SCALANCE X308-2M PoE, SCALANCE X308-2M TS, SCALANCE X308-2M TS, SCALANCE X310, SCALANCE X310, SCALANCE X310FE, SCALANCE X310FE, SCALANCE X320-1 FE, SCALANCE X320-1-2LD FE, SCALANCE X408-2, SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M TS (24V), SCALANCE XR324-12M TS (24V), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M PoE (230V, ports on front), SCALANCE XR324-4M PoE (230V, ports on rear), SCALANCE XR324-4M PoE (24V, ports on front), SCALANCE XR324-4M PoE (24V, ports on rear), SCALANCE XR324-4M PoE TS (24V, ports on front), SIPLUS NET SCALANCE X308-2. The integrated web server of the affected device could allow remote attackers to perform actions with the permissions of a victim user, provided the victim user has an active session and is induced to trigger the malicious request. plural SCALANCE The product contains a cross-site request forgery vulnerability.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. SCALANCE X switches are used to connect industrial components such as programmable logic controllers (PLC) or human machine interfaces (HMI). SIPLUS extreme is designed for reliable operation under extreme conditions

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202204-0495",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "scalance xr324-4m eec",
        "scope": "lt",
        "trust": 1.6,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance xr324-4m poe",
        "scope": "lt",
        "trust": 1.6,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance xr324-4m poe ts",
        "scope": "lt",
        "trust": 1.6,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance xr324-12m",
        "scope": "lt",
        "trust": 1.6,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance xr324-12m ts",
        "scope": "lt",
        "trust": 1.6,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance x308-2m",
        "scope": "lt",
        "trust": 1.6,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance x307-3ld",
        "scope": "lt",
        "trust": 1.6,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance x304-2fe",
        "scope": "lt",
        "trust": 1.6,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance x310fe",
        "scope": "lt",
        "trust": 1.6,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance x308-2m ts",
        "scope": "lt",
        "trust": 1.6,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance x308-2ld",
        "scope": "lt",
        "trust": 1.6,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance x308-2lh",
        "scope": "lt",
        "trust": 1.6,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance x320-1fe",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance x307-3",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance x302-7eec",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance x320-1-2ldfe",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "siplus net scalance x308-2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance x408-2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance x308-2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance x306-1ldfe",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance x308-2m poe",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance x308-2lh\\+",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance x310",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance x307-2eec",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance x304-2fe",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance x307-3ld",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance x307-3",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance x308-2",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance x307-2eec",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance x308-2ld",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance x308-2lh+",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance x308-2lh",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance x306-1ldfe",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance x302-7eec",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance fe",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "x320-1\u003c4.1.4"
      },
      {
        "model": "scalance x320-1-2ld fe",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "x408-2\u003c4.1.4"
      },
      {
        "model": "siplus net scalance",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "x308-2\u003c4.1.4"
      },
      {
        "model": "scalance",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "x307-3\u003c4.1.4"
      },
      {
        "model": "scalance eec",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "x307-2\u003c4.1.4"
      },
      {
        "model": "scalance x306-1ld fe",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance eec",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "x302-7\u003c4.1.4"
      },
      {
        "model": "scalance",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "x310\u003c4.1.4"
      },
      {
        "model": "scalance x308-2m poe",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "x308-2\u003c4.1.4"
      },
      {
        "model": "scalance x308-2lh+",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.1.4"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-28483"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-001595"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-25754"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x302-7eec_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x302-7eec:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x304-2fe_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x304-2fe:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x306-1ldfe_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x306-1ldfe:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x307-2eec_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x307-2eec:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x307-3_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x307-3:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x307-3ld_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x307-3ld:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x308-2_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x308-2:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x308-2ld_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x308-2ld:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x308-2lh_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x308-2lh:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x308-2lh\\+_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x308-2lh\\+:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x308-2m_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x308-2m:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x308-2m_poe_firmware:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x308-2m_poe:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x308-2m_ts_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x308-2m_ts:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x310_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x310:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x310fe_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x310fe:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x320-1fe_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x320-1fe:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x320-1-2ldfe_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x320-1-2ldfe:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x408-2_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x408-2:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xr324-4m_eec_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xr324-4m_eec:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xr324-4m_poe_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xr324-4m_poe:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xr324-4m_poe_ts_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xr324-4m_poe_ts:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xr324-12m_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xr324-12m:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xr324-12m_ts_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xr324-12m_ts:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:siplus_net_scalance_x308-2_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:siplus_net_scalance_x308-2:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2022-25754"
      }
    ]
  },
  "credits": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/credits#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Michael Messner and Abian Blome of Siemens Energy coordinated the disclosure of CVE-2022-25751 and CVE-2022-25756 to CISA.",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202204-3139"
      }
    ],
    "trust": 0.6
  },
  "cve": "CVE-2022-25754",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "acInsufInfo": false,
            "accessComplexity": "MEDIUM",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "NVD",
            "availabilityImpact": "PARTIAL",
            "baseScore": 6.8,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 8.6,
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "severity": "MEDIUM",
            "trust": 1.0,
            "userInteractionRequired": true,
            "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          },
          {
            "acInsufInfo": null,
            "accessComplexity": "Medium",
            "accessVector": "Network",
            "authentication": "None",
            "author": "NVD",
            "availabilityImpact": "Partial",
            "baseScore": 6.8,
            "confidentialityImpact": "Partial",
            "exploitabilityScore": null,
            "id": "CVE-2022-25754",
            "impactScore": null,
            "integrityImpact": "Partial",
            "obtainAllPrivilege": null,
            "obtainOtherPrivilege": null,
            "obtainUserPrivilege": null,
            "severity": "Medium",
            "trust": 0.9,
            "userInteractionRequired": null,
            "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "ADJACENT_NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 7.8,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 6.5,
            "id": "CNVD-2022-28483",
            "impactScore": 9.2,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 0.6,
            "vectorString": "AV:A/AC:L/Au:N/C:N/I:C/A:C",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "NVD",
            "availabilityImpact": "HIGH",
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 2.8,
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 8.8,
            "baseSeverity": "High",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "CVE-2022-25754",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "Required",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "NVD",
            "id": "CVE-2022-25754",
            "trust": 1.8,
            "value": "HIGH"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2022-28483",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202204-3139",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "VULMON",
            "id": "CVE-2022-25754",
            "trust": 0.1,
            "value": "MEDIUM"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-28483"
      },
      {
        "db": "VULMON",
        "id": "CVE-2022-25754"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-001595"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-25754"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202204-3139"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "A vulnerability has been identified in SCALANCE X302-7 EEC (230V), SCALANCE X302-7 EEC (230V, coated), SCALANCE X302-7 EEC (24V), SCALANCE X302-7 EEC (24V, coated), SCALANCE X302-7 EEC (2x 230V), SCALANCE X302-7 EEC (2x 230V, coated), SCALANCE X302-7 EEC (2x 24V), SCALANCE X302-7 EEC (2x 24V, coated), SCALANCE X304-2FE, SCALANCE X306-1LD FE, SCALANCE X307-2 EEC (230V), SCALANCE X307-2 EEC (230V, coated), SCALANCE X307-2 EEC (24V), SCALANCE X307-2 EEC (24V, coated), SCALANCE X307-2 EEC (2x 230V), SCALANCE X307-2 EEC (2x 230V, coated), SCALANCE X307-2 EEC (2x 24V), SCALANCE X307-2 EEC (2x 24V, coated), SCALANCE X307-3, SCALANCE X307-3, SCALANCE X307-3LD, SCALANCE X307-3LD, SCALANCE X308-2, SCALANCE X308-2, SCALANCE X308-2LD, SCALANCE X308-2LD, SCALANCE X308-2LH, SCALANCE X308-2LH, SCALANCE X308-2LH+, SCALANCE X308-2LH+, SCALANCE X308-2M, SCALANCE X308-2M, SCALANCE X308-2M PoE, SCALANCE X308-2M PoE, SCALANCE X308-2M TS, SCALANCE X308-2M TS, SCALANCE X310, SCALANCE X310, SCALANCE X310FE, SCALANCE X310FE, SCALANCE X320-1 FE, SCALANCE X320-1-2LD FE, SCALANCE X408-2, SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M TS (24V), SCALANCE XR324-12M TS (24V), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M PoE (230V, ports on front), SCALANCE XR324-4M PoE (230V, ports on rear), SCALANCE XR324-4M PoE (24V, ports on front), SCALANCE XR324-4M PoE (24V, ports on rear), SCALANCE XR324-4M PoE TS (24V, ports on front), SIPLUS NET SCALANCE X308-2. The integrated web server of the affected device could allow remote attackers to perform actions with the permissions of a victim user, provided the victim user has an active session and is induced to trigger the malicious request. plural  SCALANCE The product contains a cross-site request forgery vulnerability.Information is obtained, information is tampered with, and service is disrupted  (DoS) It may be put into a state. SCALANCE X switches are used to connect industrial components such as programmable logic controllers (PLC) or human machine interfaces (HMI). SIPLUS extreme is designed for reliable operation under extreme conditions",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2022-25754"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-001595"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2022-28483"
      },
      {
        "db": "VULMON",
        "id": "CVE-2022-25754"
      }
    ],
    "trust": 2.25
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2022-25754",
        "trust": 3.9
      },
      {
        "db": "SIEMENS",
        "id": "SSA-836527",
        "trust": 2.3
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-22-104-09",
        "trust": 1.5
      },
      {
        "db": "JVN",
        "id": "JVNVU91165555",
        "trust": 0.8
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-001595",
        "trust": 0.8
      },
      {
        "db": "CNVD",
        "id": "CNVD-2022-28483",
        "trust": 0.6
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202204-3139",
        "trust": 0.6
      },
      {
        "db": "VULMON",
        "id": "CVE-2022-25754",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-28483"
      },
      {
        "db": "VULMON",
        "id": "CVE-2022-25754"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-001595"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-25754"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202204-3139"
      }
    ]
  },
  "id": "VAR-202204-0495",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-28483"
      }
    ],
    "trust": 1.2919426426666667
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-28483"
      }
    ]
  },
  "last_update_date": "2023-12-18T11:56:14.715000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "SSA-836527",
        "trust": 0.8,
        "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-836527.pdf"
      },
      {
        "title": "Patch for Siemens SCALANCE X-300 Switch Family Devices Cross-Site Request Forgery Vulnerability",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchinfo/show/329316"
      },
      {
        "title": "Multiple  Siemens Repair measures for product cross-site request forgery vulnerability",
        "trust": 0.6,
        "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=190129"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-28483"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-001595"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202204-3139"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-352",
        "trust": 1.0
      },
      {
        "problemtype": "Cross-site request forgery (CWE-352) [NVD Evaluation ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-001595"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-25754"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.3,
        "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-836527.pdf"
      },
      {
        "trust": 0.9,
        "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-104-09"
      },
      {
        "trust": 0.8,
        "url": "https://jvn.jp/vu/jvnvu91165555/"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2022-25754"
      },
      {
        "trust": 0.6,
        "url": "https://cxsecurity.com/cveshow/cve-2022-25754/"
      },
      {
        "trust": 0.6,
        "url": "https://us-cert.cisa.gov/ics/advisories/icsa-22-104-09"
      },
      {
        "trust": 0.1,
        "url": "https://cwe.mitre.org/data/definitions/352.html"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-28483"
      },
      {
        "db": "VULMON",
        "id": "CVE-2022-25754"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-001595"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-25754"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202204-3139"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-28483"
      },
      {
        "db": "VULMON",
        "id": "CVE-2022-25754"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-001595"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-25754"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202204-3139"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2022-04-13T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2022-28483"
      },
      {
        "date": "2022-04-12T00:00:00",
        "db": "VULMON",
        "id": "CVE-2022-25754"
      },
      {
        "date": "2022-04-26T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2022-001595"
      },
      {
        "date": "2022-04-12T09:15:14.747000",
        "db": "NVD",
        "id": "CVE-2022-25754"
      },
      {
        "date": "2022-04-12T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202204-3139"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2022-04-13T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2022-28483"
      },
      {
        "date": "2022-04-19T00:00:00",
        "db": "VULMON",
        "id": "CVE-2022-25754"
      },
      {
        "date": "2022-04-26T09:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2022-001595"
      },
      {
        "date": "2022-04-19T18:09:34.047000",
        "db": "NVD",
        "id": "CVE-2022-25754"
      },
      {
        "date": "2022-04-20T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202204-3139"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202204-3139"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "plural \u00a0SCALANCE\u00a0 Cross-site request forgery vulnerability in product",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-001595"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "cross-site request forgery",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202204-3139"
      }
    ],
    "trust": 0.6
  }
}

var-202204-0497
Vulnerability from variot

A vulnerability has been identified in SCALANCE X302-7 EEC (230V), SCALANCE X302-7 EEC (230V, coated), SCALANCE X302-7 EEC (24V), SCALANCE X302-7 EEC (24V, coated), SCALANCE X302-7 EEC (2x 230V), SCALANCE X302-7 EEC (2x 230V, coated), SCALANCE X302-7 EEC (2x 24V), SCALANCE X302-7 EEC (2x 24V, coated), SCALANCE X304-2FE, SCALANCE X306-1LD FE, SCALANCE X307-2 EEC (230V), SCALANCE X307-2 EEC (230V, coated), SCALANCE X307-2 EEC (24V), SCALANCE X307-2 EEC (24V, coated), SCALANCE X307-2 EEC (2x 230V), SCALANCE X307-2 EEC (2x 230V, coated), SCALANCE X307-2 EEC (2x 24V), SCALANCE X307-2 EEC (2x 24V, coated), SCALANCE X307-3, SCALANCE X307-3, SCALANCE X307-3LD, SCALANCE X307-3LD, SCALANCE X308-2, SCALANCE X308-2, SCALANCE X308-2LD, SCALANCE X308-2LD, SCALANCE X308-2LH, SCALANCE X308-2LH, SCALANCE X308-2LH+, SCALANCE X308-2LH+, SCALANCE X308-2M, SCALANCE X308-2M, SCALANCE X308-2M PoE, SCALANCE X308-2M PoE, SCALANCE X308-2M TS, SCALANCE X308-2M TS, SCALANCE X310, SCALANCE X310, SCALANCE X310FE, SCALANCE X310FE, SCALANCE X320-1 FE, SCALANCE X320-1-2LD FE, SCALANCE X408-2, SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M TS (24V), SCALANCE XR324-12M TS (24V), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M PoE (230V, ports on front), SCALANCE XR324-4M PoE (230V, ports on rear), SCALANCE XR324-4M PoE (24V, ports on front), SCALANCE XR324-4M PoE (24V, ports on rear), SCALANCE XR324-4M PoE TS (24V, ports on front), SIPLUS NET SCALANCE X308-2. Affected devices do not properly validate the GET parameter XNo of incoming HTTP requests. This could allow an unauthenticated remote attacker to crash affected devices. SCALANCE X302-7EEC firmware, SCALANCE X304-2FE firmware, SCALANCE X306-1LDFE Multiple Siemens products, such as firmware, contain a classic buffer overflow vulnerability.Service operation interruption (DoS) It may be in a state. SCALANCE X switches are used to connect industrial components such as programmable logic controllers (PLC) or human machine interfaces (HMI). SIPLUS extreme is designed for reliable operation under extreme conditions.

A buffer overflow vulnerability exists in Siemens SCALANCE X-300 Switch Family Devices that could allow attackers to crash the device

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202204-0497",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "scalance xr324-4m eec",
        "scope": "lt",
        "trust": 1.6,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance xr324-4m poe",
        "scope": "lt",
        "trust": 1.6,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance xr324-4m poe ts",
        "scope": "lt",
        "trust": 1.6,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance xr324-12m",
        "scope": "lt",
        "trust": 1.6,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance xr324-12m ts",
        "scope": "lt",
        "trust": 1.6,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance x308-2m",
        "scope": "lt",
        "trust": 1.6,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance x307-3ld",
        "scope": "lt",
        "trust": 1.6,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance x304-2fe",
        "scope": "lt",
        "trust": 1.6,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance x310fe",
        "scope": "lt",
        "trust": 1.6,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance x308-2m ts",
        "scope": "lt",
        "trust": 1.6,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance x308-2ld",
        "scope": "lt",
        "trust": 1.6,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance x308-2lh",
        "scope": "lt",
        "trust": 1.6,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance x320-1fe",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance x307-3",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance x302-7eec",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance x320-1-2ldfe",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "siplus net scalance x308-2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance x408-2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance x308-2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance x306-1ldfe",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance x308-2m poe",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance x308-2lh\\+",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance x310",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance x307-2eec",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance x308-2lh",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance x308-2m",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance x408-2",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance x304-2fe",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance x308-2ld",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance x310fe",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance x308-2lh+",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance x306-1ldfe",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance xr324-4m eec",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance x308-2m ts",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance x302-7eec",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance x320-1fe",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance x307-3",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance x307-3ld",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance x320-1-2ldfe",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance x310",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance x308-2m poe",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance x308-2",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance xr324-4m poe",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance x307-2eec",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance fe",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "x320-1\u003c4.1.4"
      },
      {
        "model": "scalance x320-1-2ld fe",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "x408-2\u003c4.1.4"
      },
      {
        "model": "siplus net scalance",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "x308-2\u003c4.1.4"
      },
      {
        "model": "scalance",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "x307-3\u003c4.1.4"
      },
      {
        "model": "scalance eec",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "x307-2\u003c4.1.4"
      },
      {
        "model": "scalance x306-1ld fe",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance eec",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "x302-7\u003c4.1.4"
      },
      {
        "model": "scalance",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "x310\u003c4.1.4"
      },
      {
        "model": "scalance x308-2m poe",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "x308-2\u003c4.1.4"
      },
      {
        "model": "scalance x308-2lh+",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.1.4"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-28480"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-008107"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-26334"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x302-7eec_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x302-7eec:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x304-2fe_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x304-2fe:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x306-1ldfe_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x306-1ldfe:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x307-2eec_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x307-2eec:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x307-3_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x307-3:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x307-3ld_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x307-3ld:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x308-2_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x308-2:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x308-2ld_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x308-2ld:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x308-2lh_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x308-2lh:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x308-2lh\\+_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x308-2lh\\+:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x308-2m_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x308-2m:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x308-2m_poe_firmware:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x308-2m_poe:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x308-2m_ts_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x308-2m_ts:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x310_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x310:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x310fe_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x310fe:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x320-1fe_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x320-1fe:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x320-1-2ldfe_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x320-1-2ldfe:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x408-2_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x408-2:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xr324-4m_eec_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xr324-4m_eec:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xr324-4m_poe_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xr324-4m_poe:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xr324-4m_poe_ts_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xr324-4m_poe_ts:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xr324-12m_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xr324-12m:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xr324-12m_ts_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xr324-12m_ts:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:siplus_net_scalance_x308-2_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:siplus_net_scalance_x308-2:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2022-26334"
      }
    ]
  },
  "credits": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/credits#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Michael Messner and Abian Blome of Siemens Energy coordinated the disclosure of CVE-2022-25751 and CVE-2022-25756 to CISA.",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202204-3135"
      }
    ],
    "trust": 0.6
  },
  "cve": "CVE-2022-26334",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "acInsufInfo": false,
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "NVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 7.8,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 10.0,
            "impactScore": 6.9,
            "integrityImpact": "NONE",
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "severity": "HIGH",
            "trust": 1.0,
            "userInteractionRequired": false,
            "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
            "version": "2.0"
          },
          {
            "acInsufInfo": null,
            "accessComplexity": "Low",
            "accessVector": "Network",
            "authentication": "None",
            "author": "NVD",
            "availabilityImpact": "Complete",
            "baseScore": 7.8,
            "confidentialityImpact": "None",
            "exploitabilityScore": null,
            "id": "CVE-2022-26334",
            "impactScore": null,
            "integrityImpact": "None",
            "obtainAllPrivilege": null,
            "obtainOtherPrivilege": null,
            "obtainUserPrivilege": null,
            "severity": "High",
            "trust": 0.9,
            "userInteractionRequired": null,
            "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "ADJACENT_NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 7.3,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 6.5,
            "id": "CNVD-2022-28480",
            "impactScore": 8.5,
            "integrityImpact": "PARTIAL",
            "severity": "HIGH",
            "trust": 0.6,
            "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:C",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "NVD",
            "availabilityImpact": "HIGH",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 3.9,
            "impactScore": 3.6,
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 7.5,
            "baseSeverity": "High",
            "confidentialityImpact": "None",
            "exploitabilityScore": null,
            "id": "CVE-2022-26334",
            "impactScore": null,
            "integrityImpact": "None",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "NVD",
            "id": "CVE-2022-26334",
            "trust": 1.8,
            "value": "HIGH"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2022-28480",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202204-3135",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "VULMON",
            "id": "CVE-2022-26334",
            "trust": 0.1,
            "value": "HIGH"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-28480"
      },
      {
        "db": "VULMON",
        "id": "CVE-2022-26334"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-008107"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-26334"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202204-3135"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "A vulnerability has been identified in SCALANCE X302-7 EEC (230V), SCALANCE X302-7 EEC (230V, coated), SCALANCE X302-7 EEC (24V), SCALANCE X302-7 EEC (24V, coated), SCALANCE X302-7 EEC (2x 230V), SCALANCE X302-7 EEC (2x 230V, coated), SCALANCE X302-7 EEC (2x 24V), SCALANCE X302-7 EEC (2x 24V, coated), SCALANCE X304-2FE, SCALANCE X306-1LD FE, SCALANCE X307-2 EEC (230V), SCALANCE X307-2 EEC (230V, coated), SCALANCE X307-2 EEC (24V), SCALANCE X307-2 EEC (24V, coated), SCALANCE X307-2 EEC (2x 230V), SCALANCE X307-2 EEC (2x 230V, coated), SCALANCE X307-2 EEC (2x 24V), SCALANCE X307-2 EEC (2x 24V, coated), SCALANCE X307-3, SCALANCE X307-3, SCALANCE X307-3LD, SCALANCE X307-3LD, SCALANCE X308-2, SCALANCE X308-2, SCALANCE X308-2LD, SCALANCE X308-2LD, SCALANCE X308-2LH, SCALANCE X308-2LH, SCALANCE X308-2LH+, SCALANCE X308-2LH+, SCALANCE X308-2M, SCALANCE X308-2M, SCALANCE X308-2M PoE, SCALANCE X308-2M PoE, SCALANCE X308-2M TS, SCALANCE X308-2M TS, SCALANCE X310, SCALANCE X310, SCALANCE X310FE, SCALANCE X310FE, SCALANCE X320-1 FE, SCALANCE X320-1-2LD FE, SCALANCE X408-2, SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M TS (24V), SCALANCE XR324-12M TS (24V), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M PoE (230V, ports on front), SCALANCE XR324-4M PoE (230V, ports on rear), SCALANCE XR324-4M PoE (24V, ports on front), SCALANCE XR324-4M PoE (24V, ports on rear), SCALANCE XR324-4M PoE TS (24V, ports on front), SIPLUS NET SCALANCE X308-2. Affected devices do not properly validate the GET parameter XNo of incoming HTTP requests. This could allow an unauthenticated remote attacker to crash affected devices. SCALANCE X302-7EEC firmware, SCALANCE X304-2FE firmware, SCALANCE X306-1LDFE Multiple Siemens products, such as firmware, contain a classic buffer overflow vulnerability.Service operation interruption (DoS) It may be in a state. SCALANCE X switches are used to connect industrial components such as programmable logic controllers (PLC) or human machine interfaces (HMI). SIPLUS extreme is designed for reliable operation under extreme conditions. \n\r\n\r\nA buffer overflow vulnerability exists in Siemens SCALANCE X-300 Switch Family Devices that could allow attackers to crash the device",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2022-26334"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-008107"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2022-28480"
      },
      {
        "db": "VULMON",
        "id": "CVE-2022-26334"
      }
    ],
    "trust": 2.25
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2022-26334",
        "trust": 3.9
      },
      {
        "db": "SIEMENS",
        "id": "SSA-836527",
        "trust": 3.1
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-22-104-09",
        "trust": 1.5
      },
      {
        "db": "JVN",
        "id": "JVNVU91165555",
        "trust": 0.8
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-008107",
        "trust": 0.8
      },
      {
        "db": "CNVD",
        "id": "CNVD-2022-28480",
        "trust": 0.6
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202204-3135",
        "trust": 0.6
      },
      {
        "db": "VULMON",
        "id": "CVE-2022-26334",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-28480"
      },
      {
        "db": "VULMON",
        "id": "CVE-2022-26334"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-008107"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-26334"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202204-3135"
      }
    ]
  },
  "id": "VAR-202204-0497",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-28480"
      }
    ],
    "trust": 1.2919426426666667
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "ICS"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-28480"
      }
    ]
  },
  "last_update_date": "2023-12-18T11:56:14.777000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "Patch for Siemens SCALANCE X-300 Switch Family Devices Buffer Overflow Vulnerability (CNVD-2022-28480)",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchinfo/show/329336"
      },
      {
        "title": "Siemens SCALANCE Security vulnerabilities",
        "trust": 0.6,
        "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=190126"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-28480"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202204-3135"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-120",
        "trust": 1.0
      },
      {
        "problemtype": "Classic buffer overflow (CWE-120) [NVD evaluation ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-008107"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-26334"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 3.1,
        "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-836527.pdf"
      },
      {
        "trust": 0.8,
        "url": "https://jvn.jp/vu/jvnvu91165555/"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2022-26334"
      },
      {
        "trust": 0.8,
        "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-22-104-09"
      },
      {
        "trust": 0.6,
        "url": "https://cxsecurity.com/cveshow/cve-2022-26334/"
      },
      {
        "trust": 0.6,
        "url": "https://us-cert.cisa.gov/ics/advisories/icsa-22-104-09"
      },
      {
        "trust": 0.1,
        "url": "https://cwe.mitre.org/data/definitions/120.html"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov"
      },
      {
        "trust": 0.1,
        "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-104-09"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-28480"
      },
      {
        "db": "VULMON",
        "id": "CVE-2022-26334"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-008107"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-26334"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202204-3135"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-28480"
      },
      {
        "db": "VULMON",
        "id": "CVE-2022-26334"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-008107"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-26334"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202204-3135"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2022-04-13T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2022-28480"
      },
      {
        "date": "2022-04-12T00:00:00",
        "db": "VULMON",
        "id": "CVE-2022-26334"
      },
      {
        "date": "2023-07-24T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2022-008107"
      },
      {
        "date": "2022-04-12T09:15:14.880000",
        "db": "NVD",
        "id": "CVE-2022-26334"
      },
      {
        "date": "2022-04-12T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202204-3135"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2022-04-13T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2022-28480"
      },
      {
        "date": "2022-04-19T00:00:00",
        "db": "VULMON",
        "id": "CVE-2022-26334"
      },
      {
        "date": "2023-07-24T08:22:00",
        "db": "JVNDB",
        "id": "JVNDB-2022-008107"
      },
      {
        "date": "2022-04-19T18:14:00.127000",
        "db": "NVD",
        "id": "CVE-2022-26334"
      },
      {
        "date": "2022-04-20T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202204-3135"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202204-3135"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Classic buffer overflow vulnerability in multiple Siemens products",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-008107"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "other",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202204-3135"
      }
    ],
    "trust": 0.6
  }
}

var-202204-0502
Vulnerability from variot

A vulnerability has been identified in SCALANCE X302-7 EEC (230V), SCALANCE X302-7 EEC (230V, coated), SCALANCE X302-7 EEC (24V), SCALANCE X302-7 EEC (24V, coated), SCALANCE X302-7 EEC (2x 230V), SCALANCE X302-7 EEC (2x 230V, coated), SCALANCE X302-7 EEC (2x 24V), SCALANCE X302-7 EEC (2x 24V, coated), SCALANCE X304-2FE, SCALANCE X306-1LD FE, SCALANCE X307-2 EEC (230V), SCALANCE X307-2 EEC (230V, coated), SCALANCE X307-2 EEC (24V), SCALANCE X307-2 EEC (24V, coated), SCALANCE X307-2 EEC (2x 230V), SCALANCE X307-2 EEC (2x 230V, coated), SCALANCE X307-2 EEC (2x 24V), SCALANCE X307-2 EEC (2x 24V, coated), SCALANCE X307-3, SCALANCE X307-3, SCALANCE X307-3LD, SCALANCE X307-3LD, SCALANCE X308-2, SCALANCE X308-2, SCALANCE X308-2LD, SCALANCE X308-2LD, SCALANCE X308-2LH, SCALANCE X308-2LH, SCALANCE X308-2LH+, SCALANCE X308-2LH+, SCALANCE X308-2M, SCALANCE X308-2M, SCALANCE X308-2M PoE, SCALANCE X308-2M PoE, SCALANCE X308-2M TS, SCALANCE X308-2M TS, SCALANCE X310, SCALANCE X310, SCALANCE X310FE, SCALANCE X310FE, SCALANCE X320-1 FE, SCALANCE X320-1-2LD FE, SCALANCE X408-2, SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M TS (24V), SCALANCE XR324-12M TS (24V), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M PoE (230V, ports on front), SCALANCE XR324-4M PoE (230V, ports on rear), SCALANCE XR324-4M PoE (24V, ports on front), SCALANCE XR324-4M PoE (24V, ports on rear), SCALANCE XR324-4M PoE TS (24V, ports on front), SIPLUS NET SCALANCE X308-2. Affected devices do not properly validate if a certain SNMP key exists. An attacker could use this to trigger a reboot of an affected device by requesting specific SNMP information from the device. SCALANCE X302-7EEC firmware, SCALANCE X304-2FE firmware, SCALANCE X306-1LDFE Multiple Siemens products, such as firmware, contain an out-of-bounds read vulnerability.Service operation interruption (DoS) It may be in a state. SCALANCE X switches are used to connect industrial components such as programmable logic controllers (PLC) or human machine interfaces (HMI). SIPLUS extreme is designed for reliable operation under extreme conditions

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202204-0502",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "scalance xr324-4m eec",
        "scope": "lt",
        "trust": 1.6,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance xr324-4m poe",
        "scope": "lt",
        "trust": 1.6,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance xr324-4m poe ts",
        "scope": "lt",
        "trust": 1.6,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance xr324-12m",
        "scope": "lt",
        "trust": 1.6,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance xr324-12m ts",
        "scope": "lt",
        "trust": 1.6,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance x308-2m",
        "scope": "lt",
        "trust": 1.6,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance x307-3ld",
        "scope": "lt",
        "trust": 1.6,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance x304-2fe",
        "scope": "lt",
        "trust": 1.6,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance x310fe",
        "scope": "lt",
        "trust": 1.6,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance x308-2m ts",
        "scope": "lt",
        "trust": 1.6,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance x308-2ld",
        "scope": "lt",
        "trust": 1.6,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance x308-2lh",
        "scope": "lt",
        "trust": 1.6,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance x320-1fe",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance x307-3",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance x302-7eec",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance x320-1-2ldfe",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "siplus net scalance x308-2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance x408-2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance x308-2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance x306-1ldfe",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance x308-2m poe",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance x308-2lh\\+",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance x310",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance x307-2eec",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance x308-2lh",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance x308-2m",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance x408-2",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance x304-2fe",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance x308-2ld",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance x310fe",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance x308-2lh+",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance x306-1ldfe",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance xr324-4m eec",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance x308-2m ts",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance x302-7eec",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance x320-1fe",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance x307-3",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance x307-3ld",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance x320-1-2ldfe",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance x310",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance x308-2m poe",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance x308-2",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance xr324-4m poe",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance x307-2eec",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance fe",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "x320-1\u003c4.1.4"
      },
      {
        "model": "scalance x320-1-2ld fe",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "x408-2\u003c4.1.4"
      },
      {
        "model": "siplus net scalance",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "x308-2\u003c4.1.4"
      },
      {
        "model": "scalance",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "x307-3\u003c4.1.4"
      },
      {
        "model": "scalance eec",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "x307-2\u003c4.1.4"
      },
      {
        "model": "scalance x306-1ld fe",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance eec",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "x302-7\u003c4.1.4"
      },
      {
        "model": "scalance",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "x310\u003c4.1.4"
      },
      {
        "model": "scalance x308-2m poe",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "x308-2\u003c4.1.4"
      },
      {
        "model": "scalance x308-2lh+",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.1.4"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-28478"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-008105"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-26380"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x302-7eec_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x302-7eec:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x304-2fe_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x304-2fe:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x306-1ldfe_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x306-1ldfe:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x307-2eec_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x307-2eec:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x307-3_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x307-3:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x307-3ld_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x307-3ld:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x308-2_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x308-2:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x308-2ld_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x308-2ld:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x308-2lh_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x308-2lh:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x308-2lh\\+_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x308-2lh\\+:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x308-2m_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x308-2m:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x308-2m_poe_firmware:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x308-2m_poe:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x308-2m_ts_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x308-2m_ts:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x310_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x310:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x310fe_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x310fe:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x320-1fe_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x320-1fe:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x320-1-2ldfe_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x320-1-2ldfe:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x408-2_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x408-2:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xr324-4m_eec_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xr324-4m_eec:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xr324-4m_poe_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xr324-4m_poe:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xr324-4m_poe_ts_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xr324-4m_poe_ts:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xr324-12m_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xr324-12m:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xr324-12m_ts_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xr324-12m_ts:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:siplus_net_scalance_x308-2_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:siplus_net_scalance_x308-2:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2022-26380"
      }
    ]
  },
  "credits": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/credits#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Michael Messner and Abian Blome of Siemens Energy coordinated the disclosure of CVE-2022-25751 and CVE-2022-25756 to CISA.",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202204-3133"
      }
    ],
    "trust": 0.6
  },
  "cve": "CVE-2022-26380",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "acInsufInfo": false,
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "NVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 7.8,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 10.0,
            "impactScore": 6.9,
            "integrityImpact": "NONE",
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "severity": "HIGH",
            "trust": 1.0,
            "userInteractionRequired": false,
            "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
            "version": "2.0"
          },
          {
            "acInsufInfo": null,
            "accessComplexity": "Low",
            "accessVector": "Network",
            "authentication": "None",
            "author": "NVD",
            "availabilityImpact": "Complete",
            "baseScore": 7.8,
            "confidentialityImpact": "None",
            "exploitabilityScore": null,
            "id": "CVE-2022-26380",
            "impactScore": null,
            "integrityImpact": "None",
            "obtainAllPrivilege": null,
            "obtainOtherPrivilege": null,
            "obtainUserPrivilege": null,
            "severity": "High",
            "trust": 0.9,
            "userInteractionRequired": null,
            "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "ADJACENT_NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 6.1,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 6.5,
            "id": "CNVD-2022-28478",
            "impactScore": 6.9,
            "integrityImpact": "NONE",
            "severity": "MEDIUM",
            "trust": 0.6,
            "vectorString": "AV:A/AC:L/Au:N/C:N/I:N/A:C",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "NVD",
            "availabilityImpact": "HIGH",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 3.9,
            "impactScore": 3.6,
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 7.5,
            "baseSeverity": "High",
            "confidentialityImpact": "None",
            "exploitabilityScore": null,
            "id": "CVE-2022-26380",
            "impactScore": null,
            "integrityImpact": "None",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "NVD",
            "id": "CVE-2022-26380",
            "trust": 1.8,
            "value": "HIGH"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2022-28478",
            "trust": 0.6,
            "value": "MEDIUM"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202204-3133",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "VULMON",
            "id": "CVE-2022-26380",
            "trust": 0.1,
            "value": "HIGH"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-28478"
      },
      {
        "db": "VULMON",
        "id": "CVE-2022-26380"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-008105"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-26380"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202204-3133"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "A vulnerability has been identified in SCALANCE X302-7 EEC (230V), SCALANCE X302-7 EEC (230V, coated), SCALANCE X302-7 EEC (24V), SCALANCE X302-7 EEC (24V, coated), SCALANCE X302-7 EEC (2x 230V), SCALANCE X302-7 EEC (2x 230V, coated), SCALANCE X302-7 EEC (2x 24V), SCALANCE X302-7 EEC (2x 24V, coated), SCALANCE X304-2FE, SCALANCE X306-1LD FE, SCALANCE X307-2 EEC (230V), SCALANCE X307-2 EEC (230V, coated), SCALANCE X307-2 EEC (24V), SCALANCE X307-2 EEC (24V, coated), SCALANCE X307-2 EEC (2x 230V), SCALANCE X307-2 EEC (2x 230V, coated), SCALANCE X307-2 EEC (2x 24V), SCALANCE X307-2 EEC (2x 24V, coated), SCALANCE X307-3, SCALANCE X307-3, SCALANCE X307-3LD, SCALANCE X307-3LD, SCALANCE X308-2, SCALANCE X308-2, SCALANCE X308-2LD, SCALANCE X308-2LD, SCALANCE X308-2LH, SCALANCE X308-2LH, SCALANCE X308-2LH+, SCALANCE X308-2LH+, SCALANCE X308-2M, SCALANCE X308-2M, SCALANCE X308-2M PoE, SCALANCE X308-2M PoE, SCALANCE X308-2M TS, SCALANCE X308-2M TS, SCALANCE X310, SCALANCE X310, SCALANCE X310FE, SCALANCE X310FE, SCALANCE X320-1 FE, SCALANCE X320-1-2LD FE, SCALANCE X408-2, SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M TS (24V), SCALANCE XR324-12M TS (24V), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M PoE (230V, ports on front), SCALANCE XR324-4M PoE (230V, ports on rear), SCALANCE XR324-4M PoE (24V, ports on front), SCALANCE XR324-4M PoE (24V, ports on rear), SCALANCE XR324-4M PoE TS (24V, ports on front), SIPLUS NET SCALANCE X308-2. Affected devices do not properly validate if a certain SNMP key exists. An attacker could use this to trigger a reboot of an affected device by requesting specific SNMP information from the device. SCALANCE X302-7EEC firmware, SCALANCE X304-2FE firmware, SCALANCE X306-1LDFE Multiple Siemens products, such as firmware, contain an out-of-bounds read vulnerability.Service operation interruption (DoS) It may be in a state. SCALANCE X switches are used to connect industrial components such as programmable logic controllers (PLC) or human machine interfaces (HMI). SIPLUS extreme is designed for reliable operation under extreme conditions",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2022-26380"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-008105"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2022-28478"
      },
      {
        "db": "VULMON",
        "id": "CVE-2022-26380"
      }
    ],
    "trust": 2.25
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2022-26380",
        "trust": 3.9
      },
      {
        "db": "SIEMENS",
        "id": "SSA-836527",
        "trust": 3.1
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-22-104-09",
        "trust": 1.5
      },
      {
        "db": "JVN",
        "id": "JVNVU91165555",
        "trust": 0.8
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-008105",
        "trust": 0.8
      },
      {
        "db": "CNVD",
        "id": "CNVD-2022-28478",
        "trust": 0.6
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202204-3133",
        "trust": 0.6
      },
      {
        "db": "VULMON",
        "id": "CVE-2022-26380",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-28478"
      },
      {
        "db": "VULMON",
        "id": "CVE-2022-26380"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-008105"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-26380"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202204-3133"
      }
    ]
  },
  "id": "VAR-202204-0502",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-28478"
      }
    ],
    "trust": 1.2919426426666667
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "ICS"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-28478"
      }
    ]
  },
  "last_update_date": "2023-12-18T11:56:14.685000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "Patch for Siemens SCALANCE X-300 Switch Family Devices Out-of-Bounds Read Vulnerability",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchinfo/show/329351"
      },
      {
        "title": "Multiple  Siemens Product Buffer Error Vulnerability Fix",
        "trust": 0.6,
        "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=190124"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-28478"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202204-3133"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-125",
        "trust": 1.0
      },
      {
        "problemtype": "Out-of-bounds read (CWE-125) [NVD evaluation ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-008105"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-26380"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 3.1,
        "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-836527.pdf"
      },
      {
        "trust": 0.8,
        "url": "https://jvn.jp/vu/jvnvu91165555/"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2022-26380"
      },
      {
        "trust": 0.8,
        "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-22-104-09"
      },
      {
        "trust": 0.6,
        "url": "https://cxsecurity.com/cveshow/cve-2022-26380/"
      },
      {
        "trust": 0.6,
        "url": "https://us-cert.cisa.gov/ics/advisories/icsa-22-104-09"
      },
      {
        "trust": 0.1,
        "url": "https://cwe.mitre.org/data/definitions/125.html"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov"
      },
      {
        "trust": 0.1,
        "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-104-09"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-28478"
      },
      {
        "db": "VULMON",
        "id": "CVE-2022-26380"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-008105"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-26380"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202204-3133"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-28478"
      },
      {
        "db": "VULMON",
        "id": "CVE-2022-26380"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-008105"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-26380"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202204-3133"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2022-04-13T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2022-28478"
      },
      {
        "date": "2022-04-12T00:00:00",
        "db": "VULMON",
        "id": "CVE-2022-26380"
      },
      {
        "date": "2023-07-24T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2022-008105"
      },
      {
        "date": "2022-04-12T09:15:14.970000",
        "db": "NVD",
        "id": "CVE-2022-26380"
      },
      {
        "date": "2022-04-12T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202204-3133"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2022-04-13T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2022-28478"
      },
      {
        "date": "2022-04-19T00:00:00",
        "db": "VULMON",
        "id": "CVE-2022-26380"
      },
      {
        "date": "2023-07-24T08:22:00",
        "db": "JVNDB",
        "id": "JVNDB-2022-008105"
      },
      {
        "date": "2022-04-19T18:15:38.797000",
        "db": "NVD",
        "id": "CVE-2022-26380"
      },
      {
        "date": "2022-04-20T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202204-3133"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202204-3133"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Out-of-bounds read vulnerabilities in multiple Siemens products",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-008105"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "buffer error",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202204-3133"
      }
    ],
    "trust": 0.6
  }
}

var-202204-0501
Vulnerability from variot

A vulnerability has been identified in SCALANCE X302-7 EEC (230V), SCALANCE X302-7 EEC (230V, coated), SCALANCE X302-7 EEC (24V), SCALANCE X302-7 EEC (24V, coated), SCALANCE X302-7 EEC (2x 230V), SCALANCE X302-7 EEC (2x 230V, coated), SCALANCE X302-7 EEC (2x 24V), SCALANCE X302-7 EEC (2x 24V, coated), SCALANCE X304-2FE, SCALANCE X306-1LD FE, SCALANCE X307-2 EEC (230V), SCALANCE X307-2 EEC (230V, coated), SCALANCE X307-2 EEC (24V), SCALANCE X307-2 EEC (24V, coated), SCALANCE X307-2 EEC (2x 230V), SCALANCE X307-2 EEC (2x 230V, coated), SCALANCE X307-2 EEC (2x 24V), SCALANCE X307-2 EEC (2x 24V, coated), SCALANCE X307-3, SCALANCE X307-3, SCALANCE X307-3LD, SCALANCE X307-3LD, SCALANCE X308-2, SCALANCE X308-2, SCALANCE X308-2LD, SCALANCE X308-2LD, SCALANCE X308-2LH, SCALANCE X308-2LH, SCALANCE X308-2LH+, SCALANCE X308-2LH+, SCALANCE X308-2M, SCALANCE X308-2M, SCALANCE X308-2M PoE, SCALANCE X308-2M PoE, SCALANCE X308-2M TS, SCALANCE X308-2M TS, SCALANCE X310, SCALANCE X310, SCALANCE X310FE, SCALANCE X310FE, SCALANCE X320-1 FE, SCALANCE X320-1-2LD FE, SCALANCE X408-2, SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M TS (24V), SCALANCE XR324-12M TS (24V), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M PoE (230V, ports on front), SCALANCE XR324-4M PoE (230V, ports on rear), SCALANCE XR324-4M PoE (24V, ports on front), SCALANCE XR324-4M PoE (24V, ports on rear), SCALANCE XR324-4M PoE TS (24V, ports on front), SIPLUS NET SCALANCE X308-2. Affected devices do not properly validate the HTTP headers of incoming requests. This could allow an unauthenticated remote attacker to crash affected devices. plural SCALANCE The product contains an input verification vulnerability.Denial of service (DoS) It may be put into a state. SCALANCE X switches are used to connect industrial components such as programmable logic controllers (PLC) or human machine interfaces (HMI). SIPLUS extreme is designed for reliable operation under extreme conditions

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202204-0501",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "scalance xr324-4m eec",
        "scope": "lt",
        "trust": 1.6,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance xr324-4m poe",
        "scope": "lt",
        "trust": 1.6,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance xr324-4m poe ts",
        "scope": "lt",
        "trust": 1.6,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance xr324-12m",
        "scope": "lt",
        "trust": 1.6,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance xr324-12m ts",
        "scope": "lt",
        "trust": 1.6,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance x308-2m",
        "scope": "lt",
        "trust": 1.6,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance x307-3ld",
        "scope": "lt",
        "trust": 1.6,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance x304-2fe",
        "scope": "lt",
        "trust": 1.6,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance x310fe",
        "scope": "lt",
        "trust": 1.6,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance x308-2m ts",
        "scope": "lt",
        "trust": 1.6,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance x308-2ld",
        "scope": "lt",
        "trust": 1.6,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance x308-2lh",
        "scope": "lt",
        "trust": 1.6,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance x320-1fe",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance x307-3",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance x302-7eec",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance x320-1-2ldfe",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "siplus net scalance x308-2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance x408-2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance x308-2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance x306-1ldfe",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance x308-2m poe",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance x308-2lh\\+",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance x310",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance x307-2eec",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance x304-2fe",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance x307-3ld",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance x307-3",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance x308-2",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance x307-2eec",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance x308-2ld",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance x308-2lh+",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance x308-2lh",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance x306-1ldfe",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance x302-7eec",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance fe",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "x320-1\u003c4.1.4"
      },
      {
        "model": "scalance x320-1-2ld fe",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "x408-2\u003c4.1.4"
      },
      {
        "model": "siplus net scalance",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "x308-2\u003c4.1.4"
      },
      {
        "model": "scalance",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "x307-3\u003c4.1.4"
      },
      {
        "model": "scalance eec",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "x307-2\u003c4.1.4"
      },
      {
        "model": "scalance x306-1ld fe",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance eec",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "x302-7\u003c4.1.4"
      },
      {
        "model": "scalance",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "x310\u003c4.1.4"
      },
      {
        "model": "scalance x308-2m poe",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "x308-2\u003c4.1.4"
      },
      {
        "model": "scalance x308-2lh+",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.1.4"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-28486"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-001578"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-25751"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x302-7eec_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x302-7eec:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x304-2fe_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x304-2fe:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x306-1ldfe_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x306-1ldfe:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x307-2eec_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x307-2eec:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x307-3_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x307-3:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x307-3ld_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x307-3ld:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x308-2_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x308-2:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x308-2ld_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x308-2ld:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x308-2lh_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x308-2lh:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x308-2lh\\+_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x308-2lh\\+:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x308-2m_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x308-2m:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x308-2m_poe_firmware:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x308-2m_poe:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x308-2m_ts_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x308-2m_ts:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x310_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x310:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x310fe_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x310fe:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x320-1fe_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x320-1fe:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x320-1-2ldfe_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x320-1-2ldfe:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x408-2_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x408-2:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xr324-4m_eec_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xr324-4m_eec:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xr324-4m_poe_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xr324-4m_poe:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xr324-4m_poe_ts_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xr324-4m_poe_ts:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xr324-12m_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xr324-12m:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xr324-12m_ts_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xr324-12m_ts:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:siplus_net_scalance_x308-2_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:siplus_net_scalance_x308-2:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2022-25751"
      }
    ]
  },
  "credits": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/credits#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Michael Messner and Abian Blome of Siemens Energy coordinated the disclosure of CVE-2022-25751 and CVE-2022-25756 to CISA.",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202204-3142"
      }
    ],
    "trust": 0.6
  },
  "cve": "CVE-2022-25751",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "acInsufInfo": false,
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "NVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 7.8,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 10.0,
            "impactScore": 6.9,
            "integrityImpact": "NONE",
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "severity": "HIGH",
            "trust": 1.0,
            "userInteractionRequired": false,
            "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
            "version": "2.0"
          },
          {
            "acInsufInfo": null,
            "accessComplexity": "Low",
            "accessVector": "Network",
            "authentication": "None",
            "author": "NVD",
            "availabilityImpact": "Complete",
            "baseScore": 7.8,
            "confidentialityImpact": "None",
            "exploitabilityScore": null,
            "id": "CVE-2022-25751",
            "impactScore": null,
            "integrityImpact": "None",
            "obtainAllPrivilege": null,
            "obtainOtherPrivilege": null,
            "obtainUserPrivilege": null,
            "severity": "High",
            "trust": 0.9,
            "userInteractionRequired": null,
            "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "ADJACENT_NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 6.8,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 6.5,
            "id": "CNVD-2022-28486",
            "impactScore": 7.8,
            "integrityImpact": "NONE",
            "severity": "MEDIUM",
            "trust": 0.6,
            "vectorString": "AV:A/AC:L/Au:N/C:P/I:N/A:C",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "NVD",
            "availabilityImpact": "HIGH",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 3.9,
            "impactScore": 3.6,
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 7.5,
            "baseSeverity": "High",
            "confidentialityImpact": "None",
            "exploitabilityScore": null,
            "id": "CVE-2022-25751",
            "impactScore": null,
            "integrityImpact": "None",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "NVD",
            "id": "CVE-2022-25751",
            "trust": 1.8,
            "value": "HIGH"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2022-28486",
            "trust": 0.6,
            "value": "MEDIUM"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202204-3142",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "VULMON",
            "id": "CVE-2022-25751",
            "trust": 0.1,
            "value": "HIGH"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-28486"
      },
      {
        "db": "VULMON",
        "id": "CVE-2022-25751"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-001578"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-25751"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202204-3142"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "A vulnerability has been identified in SCALANCE X302-7 EEC (230V), SCALANCE X302-7 EEC (230V, coated), SCALANCE X302-7 EEC (24V), SCALANCE X302-7 EEC (24V, coated), SCALANCE X302-7 EEC (2x 230V), SCALANCE X302-7 EEC (2x 230V, coated), SCALANCE X302-7 EEC (2x 24V), SCALANCE X302-7 EEC (2x 24V, coated), SCALANCE X304-2FE, SCALANCE X306-1LD FE, SCALANCE X307-2 EEC (230V), SCALANCE X307-2 EEC (230V, coated), SCALANCE X307-2 EEC (24V), SCALANCE X307-2 EEC (24V, coated), SCALANCE X307-2 EEC (2x 230V), SCALANCE X307-2 EEC (2x 230V, coated), SCALANCE X307-2 EEC (2x 24V), SCALANCE X307-2 EEC (2x 24V, coated), SCALANCE X307-3, SCALANCE X307-3, SCALANCE X307-3LD, SCALANCE X307-3LD, SCALANCE X308-2, SCALANCE X308-2, SCALANCE X308-2LD, SCALANCE X308-2LD, SCALANCE X308-2LH, SCALANCE X308-2LH, SCALANCE X308-2LH+, SCALANCE X308-2LH+, SCALANCE X308-2M, SCALANCE X308-2M, SCALANCE X308-2M PoE, SCALANCE X308-2M PoE, SCALANCE X308-2M TS, SCALANCE X308-2M TS, SCALANCE X310, SCALANCE X310, SCALANCE X310FE, SCALANCE X310FE, SCALANCE X320-1 FE, SCALANCE X320-1-2LD FE, SCALANCE X408-2, SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M TS (24V), SCALANCE XR324-12M TS (24V), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M PoE (230V, ports on front), SCALANCE XR324-4M PoE (230V, ports on rear), SCALANCE XR324-4M PoE (24V, ports on front), SCALANCE XR324-4M PoE (24V, ports on rear), SCALANCE XR324-4M PoE TS (24V, ports on front), SIPLUS NET SCALANCE X308-2. Affected devices do not properly validate the HTTP headers of incoming requests. This could allow an unauthenticated remote attacker to crash affected devices. plural  SCALANCE The product contains an input verification vulnerability.Denial of service  (DoS) It may be put into a state. SCALANCE X switches are used to connect industrial components such as programmable logic controllers (PLC) or human machine interfaces (HMI). SIPLUS extreme is designed for reliable operation under extreme conditions",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2022-25751"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-001578"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2022-28486"
      },
      {
        "db": "VULMON",
        "id": "CVE-2022-25751"
      }
    ],
    "trust": 2.25
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2022-25751",
        "trust": 3.9
      },
      {
        "db": "SIEMENS",
        "id": "SSA-836527",
        "trust": 2.3
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-22-104-09",
        "trust": 1.5
      },
      {
        "db": "JVN",
        "id": "JVNVU91165555",
        "trust": 0.8
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-001578",
        "trust": 0.8
      },
      {
        "db": "CNVD",
        "id": "CNVD-2022-28486",
        "trust": 0.6
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202204-3142",
        "trust": 0.6
      },
      {
        "db": "VULMON",
        "id": "CVE-2022-25751",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-28486"
      },
      {
        "db": "VULMON",
        "id": "CVE-2022-25751"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-001578"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-25751"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202204-3142"
      }
    ]
  },
  "id": "VAR-202204-0501",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-28486"
      }
    ],
    "trust": 1.2919426426666667
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-28486"
      }
    ]
  },
  "last_update_date": "2023-12-18T11:56:14.840000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "SSA-836527",
        "trust": 0.8,
        "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-836527.pdf"
      },
      {
        "title": "Patch for Siemens SCALANCE X-300 Switch Family Devices Input Validation Error Vulnerability",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchinfo/show/329281"
      },
      {
        "title": "Multiple  Siemens Product input verification error vulnerability fixes",
        "trust": 0.6,
        "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=190132"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-28486"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-001578"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202204-3142"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-20",
        "trust": 1.0
      },
      {
        "problemtype": "Incorrect input confirmation (CWE-20) [NVD Evaluation ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-001578"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-25751"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.3,
        "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-836527.pdf"
      },
      {
        "trust": 0.9,
        "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-104-09"
      },
      {
        "trust": 0.8,
        "url": "http://jvn.jp/vu/jvnvu91165555/index.html"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2022-25751"
      },
      {
        "trust": 0.6,
        "url": "https://cxsecurity.com/cveshow/cve-2022-25751/"
      },
      {
        "trust": 0.6,
        "url": "https://us-cert.cisa.gov/ics/advisories/icsa-22-104-09"
      },
      {
        "trust": 0.1,
        "url": "https://cwe.mitre.org/data/definitions/20.html"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-28486"
      },
      {
        "db": "VULMON",
        "id": "CVE-2022-25751"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-001578"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-25751"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202204-3142"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-28486"
      },
      {
        "db": "VULMON",
        "id": "CVE-2022-25751"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-001578"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-25751"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202204-3142"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2022-04-13T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2022-28486"
      },
      {
        "date": "2022-04-12T00:00:00",
        "db": "VULMON",
        "id": "CVE-2022-25751"
      },
      {
        "date": "2022-04-25T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2022-001578"
      },
      {
        "date": "2022-04-12T09:15:14.597000",
        "db": "NVD",
        "id": "CVE-2022-25751"
      },
      {
        "date": "2022-04-12T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202204-3142"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2022-04-13T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2022-28486"
      },
      {
        "date": "2022-04-19T00:00:00",
        "db": "VULMON",
        "id": "CVE-2022-25751"
      },
      {
        "date": "2022-04-25T08:16:00",
        "db": "JVNDB",
        "id": "JVNDB-2022-001578"
      },
      {
        "date": "2022-04-19T16:39:26.917000",
        "db": "NVD",
        "id": "CVE-2022-25751"
      },
      {
        "date": "2022-04-20T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202204-3142"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202204-3142"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "plural \u00a0SCALANCE\u00a0 Product input verification vulnerabilities",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-001578"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "input validation error",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202204-3142"
      }
    ],
    "trust": 0.6
  }
}

var-202204-0498
Vulnerability from variot

A vulnerability has been identified in SCALANCE X302-7 EEC (230V), SCALANCE X302-7 EEC (230V, coated), SCALANCE X302-7 EEC (24V), SCALANCE X302-7 EEC (24V, coated), SCALANCE X302-7 EEC (2x 230V), SCALANCE X302-7 EEC (2x 230V, coated), SCALANCE X302-7 EEC (2x 24V), SCALANCE X302-7 EEC (2x 24V, coated), SCALANCE X304-2FE, SCALANCE X306-1LD FE, SCALANCE X307-2 EEC (230V), SCALANCE X307-2 EEC (230V, coated), SCALANCE X307-2 EEC (24V), SCALANCE X307-2 EEC (24V, coated), SCALANCE X307-2 EEC (2x 230V), SCALANCE X307-2 EEC (2x 230V, coated), SCALANCE X307-2 EEC (2x 24V), SCALANCE X307-2 EEC (2x 24V, coated), SCALANCE X307-3, SCALANCE X307-3, SCALANCE X307-3LD, SCALANCE X307-3LD, SCALANCE X308-2, SCALANCE X308-2, SCALANCE X308-2LD, SCALANCE X308-2LD, SCALANCE X308-2LH, SCALANCE X308-2LH, SCALANCE X308-2LH+, SCALANCE X308-2LH+, SCALANCE X308-2M, SCALANCE X308-2M, SCALANCE X308-2M PoE, SCALANCE X308-2M PoE, SCALANCE X308-2M TS, SCALANCE X308-2M TS, SCALANCE X310, SCALANCE X310, SCALANCE X310FE, SCALANCE X310FE, SCALANCE X320-1 FE, SCALANCE X320-1-2LD FE, SCALANCE X408-2, SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M TS (24V), SCALANCE XR324-12M TS (24V), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M PoE (230V, ports on front), SCALANCE XR324-4M PoE (230V, ports on rear), SCALANCE XR324-4M PoE (24V, ports on front), SCALANCE XR324-4M PoE (24V, ports on rear), SCALANCE XR324-4M PoE TS (24V, ports on front), SIPLUS NET SCALANCE X308-2. The handling of arguments such as IP addresses in the CLI of affected devices is prone to buffer overflows. This could allow an authenticated remote attacker to execute arbitrary code on the device. plural SCALANCE The product contains a vulnerability related to out-of-bounds writing.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. SCALANCE X switches are used to connect industrial components such as programmable logic controllers (PLC) or human machine interfaces (HMI). SIPLUS extreme is designed for reliable operation under extreme conditions

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202204-0498",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "scalance xr324-4m eec",
        "scope": "lt",
        "trust": 1.6,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance xr324-4m poe",
        "scope": "lt",
        "trust": 1.6,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance xr324-4m poe ts",
        "scope": "lt",
        "trust": 1.6,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance xr324-12m",
        "scope": "lt",
        "trust": 1.6,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance xr324-12m ts",
        "scope": "lt",
        "trust": 1.6,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance x308-2m",
        "scope": "lt",
        "trust": 1.6,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance x307-3ld",
        "scope": "lt",
        "trust": 1.6,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance x304-2fe",
        "scope": "lt",
        "trust": 1.6,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance x310fe",
        "scope": "lt",
        "trust": 1.6,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance x308-2m ts",
        "scope": "lt",
        "trust": 1.6,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance x308-2ld",
        "scope": "lt",
        "trust": 1.6,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance x308-2lh",
        "scope": "lt",
        "trust": 1.6,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance x320-1fe",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance x307-3",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance x302-7eec",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance x320-1-2ldfe",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "siplus net scalance x308-2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance x408-2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance x308-2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance x306-1ldfe",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance x308-2m poe",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance x308-2lh\\+",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance x310",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance x307-2eec",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance x304-2fe",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance x307-3ld",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance x307-3",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance x308-2",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance x307-2eec",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance x308-2ld",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance x308-2lh+",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance x308-2lh",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance x306-1ldfe",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance x302-7eec",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance fe",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "x320-1\u003c4.1.4"
      },
      {
        "model": "scalance x320-1-2ld fe",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "x408-2\u003c4.1.4"
      },
      {
        "model": "siplus net scalance",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "x308-2\u003c4.1.4"
      },
      {
        "model": "scalance",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "x307-3\u003c4.1.4"
      },
      {
        "model": "scalance eec",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "x307-2\u003c4.1.4"
      },
      {
        "model": "scalance x306-1ld fe",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance eec",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "x302-7\u003c4.1.4"
      },
      {
        "model": "scalance",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "x310\u003c4.1.4"
      },
      {
        "model": "scalance x308-2m poe",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "x308-2\u003c4.1.4"
      },
      {
        "model": "scalance x308-2lh+",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.1.4"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-28484"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-001596"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-25753"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x302-7eec_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x302-7eec:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x304-2fe_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x304-2fe:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x306-1ldfe_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x306-1ldfe:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x307-2eec_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x307-2eec:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x307-3_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x307-3:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x307-3ld_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x307-3ld:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x308-2_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x308-2:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x308-2ld_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x308-2ld:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x308-2lh_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x308-2lh:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x308-2lh\\+_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x308-2lh\\+:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x308-2m_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x308-2m:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x308-2m_poe_firmware:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x308-2m_poe:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x308-2m_ts_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x308-2m_ts:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x310_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x310:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x310fe_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x310fe:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x320-1fe_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x320-1fe:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x320-1-2ldfe_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x320-1-2ldfe:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x408-2_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x408-2:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xr324-4m_eec_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xr324-4m_eec:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xr324-4m_poe_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xr324-4m_poe:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xr324-4m_poe_ts_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xr324-4m_poe_ts:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xr324-12m_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xr324-12m:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xr324-12m_ts_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xr324-12m_ts:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:siplus_net_scalance_x308-2_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:siplus_net_scalance_x308-2:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2022-25753"
      }
    ]
  },
  "credits": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/credits#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Michael Messner and Abian Blome of Siemens Energy coordinated the disclosure of CVE-2022-25751 and CVE-2022-25756 to CISA.",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202204-3141"
      }
    ],
    "trust": 0.6
  },
  "cve": "CVE-2022-25753",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "acInsufInfo": false,
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "SINGLE",
            "author": "NVD",
            "availabilityImpact": "PARTIAL",
            "baseScore": 6.5,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 8.0,
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "severity": "MEDIUM",
            "trust": 1.0,
            "userInteractionRequired": false,
            "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
            "version": "2.0"
          },
          {
            "acInsufInfo": null,
            "accessComplexity": "Low",
            "accessVector": "Network",
            "authentication": "Single",
            "author": "NVD",
            "availabilityImpact": "Partial",
            "baseScore": 6.5,
            "confidentialityImpact": "Partial",
            "exploitabilityScore": null,
            "id": "CVE-2022-25753",
            "impactScore": null,
            "integrityImpact": "Partial",
            "obtainAllPrivilege": null,
            "obtainOtherPrivilege": null,
            "obtainUserPrivilege": null,
            "severity": "Medium",
            "trust": 0.9,
            "userInteractionRequired": null,
            "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
            "version": "2.0"
          },
          {
            "accessComplexity": "HIGH",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 7.6,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 4.9,
            "id": "CNVD-2022-28484",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 0.6,
            "vectorString": "AV:N/AC:H/Au:N/C:C/I:C/A:C",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "NVD",
            "availabilityImpact": "HIGH",
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 2.8,
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 8.8,
            "baseSeverity": "High",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "CVE-2022-25753",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "Low",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "NVD",
            "id": "CVE-2022-25753",
            "trust": 1.8,
            "value": "HIGH"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2022-28484",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202204-3141",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "VULMON",
            "id": "CVE-2022-25753",
            "trust": 0.1,
            "value": "MEDIUM"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-28484"
      },
      {
        "db": "VULMON",
        "id": "CVE-2022-25753"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-001596"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-25753"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202204-3141"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "A vulnerability has been identified in SCALANCE X302-7 EEC (230V), SCALANCE X302-7 EEC (230V, coated), SCALANCE X302-7 EEC (24V), SCALANCE X302-7 EEC (24V, coated), SCALANCE X302-7 EEC (2x 230V), SCALANCE X302-7 EEC (2x 230V, coated), SCALANCE X302-7 EEC (2x 24V), SCALANCE X302-7 EEC (2x 24V, coated), SCALANCE X304-2FE, SCALANCE X306-1LD FE, SCALANCE X307-2 EEC (230V), SCALANCE X307-2 EEC (230V, coated), SCALANCE X307-2 EEC (24V), SCALANCE X307-2 EEC (24V, coated), SCALANCE X307-2 EEC (2x 230V), SCALANCE X307-2 EEC (2x 230V, coated), SCALANCE X307-2 EEC (2x 24V), SCALANCE X307-2 EEC (2x 24V, coated), SCALANCE X307-3, SCALANCE X307-3, SCALANCE X307-3LD, SCALANCE X307-3LD, SCALANCE X308-2, SCALANCE X308-2, SCALANCE X308-2LD, SCALANCE X308-2LD, SCALANCE X308-2LH, SCALANCE X308-2LH, SCALANCE X308-2LH+, SCALANCE X308-2LH+, SCALANCE X308-2M, SCALANCE X308-2M, SCALANCE X308-2M PoE, SCALANCE X308-2M PoE, SCALANCE X308-2M TS, SCALANCE X308-2M TS, SCALANCE X310, SCALANCE X310, SCALANCE X310FE, SCALANCE X310FE, SCALANCE X320-1 FE, SCALANCE X320-1-2LD FE, SCALANCE X408-2, SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M TS (24V), SCALANCE XR324-12M TS (24V), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M PoE (230V, ports on front), SCALANCE XR324-4M PoE (230V, ports on rear), SCALANCE XR324-4M PoE (24V, ports on front), SCALANCE XR324-4M PoE (24V, ports on rear), SCALANCE XR324-4M PoE TS (24V, ports on front), SIPLUS NET SCALANCE X308-2. The handling of arguments such as IP addresses in the CLI of affected devices is prone to buffer overflows. This could allow an authenticated remote attacker to execute arbitrary code on the device. plural  SCALANCE The product contains a vulnerability related to out-of-bounds writing.Information is obtained, information is tampered with, and service is disrupted  (DoS) It may be put into a state. SCALANCE X switches are used to connect industrial components such as programmable logic controllers (PLC) or human machine interfaces (HMI). SIPLUS extreme is designed for reliable operation under extreme conditions",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2022-25753"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-001596"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2022-28484"
      },
      {
        "db": "VULMON",
        "id": "CVE-2022-25753"
      }
    ],
    "trust": 2.25
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2022-25753",
        "trust": 3.9
      },
      {
        "db": "SIEMENS",
        "id": "SSA-836527",
        "trust": 2.3
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-22-104-09",
        "trust": 1.5
      },
      {
        "db": "JVN",
        "id": "JVNVU91165555",
        "trust": 0.8
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-001596",
        "trust": 0.8
      },
      {
        "db": "CNVD",
        "id": "CNVD-2022-28484",
        "trust": 0.6
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202204-3141",
        "trust": 0.6
      },
      {
        "db": "VULMON",
        "id": "CVE-2022-25753",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-28484"
      },
      {
        "db": "VULMON",
        "id": "CVE-2022-25753"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-001596"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-25753"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202204-3141"
      }
    ]
  },
  "id": "VAR-202204-0498",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-28484"
      }
    ],
    "trust": 1.2919426426666667
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-28484"
      }
    ]
  },
  "last_update_date": "2023-12-18T11:56:14.560000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "SSA-836527",
        "trust": 0.8,
        "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-836527.pdf"
      },
      {
        "title": "Patch for Siemens SCALANCE X-300 Switch Family Devices Buffer Overflow Vulnerability",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchinfo/show/329311"
      },
      {
        "title": "Multiple  Siemens product Buffer error vulnerability fix",
        "trust": 0.6,
        "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=190131"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-28484"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-001596"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202204-3141"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-787",
        "trust": 1.0
      },
      {
        "problemtype": "Out-of-bounds writing (CWE-787) [NVD Evaluation ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-001596"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-25753"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.3,
        "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-836527.pdf"
      },
      {
        "trust": 0.9,
        "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-104-09"
      },
      {
        "trust": 0.8,
        "url": "https://jvn.jp/vu/jvnvu91165555/"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2022-25753"
      },
      {
        "trust": 0.6,
        "url": "https://cxsecurity.com/cveshow/cve-2022-25753/"
      },
      {
        "trust": 0.6,
        "url": "https://us-cert.cisa.gov/ics/advisories/icsa-22-104-09"
      },
      {
        "trust": 0.1,
        "url": "https://cwe.mitre.org/data/definitions/787.html"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-28484"
      },
      {
        "db": "VULMON",
        "id": "CVE-2022-25753"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-001596"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-25753"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202204-3141"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-28484"
      },
      {
        "db": "VULMON",
        "id": "CVE-2022-25753"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-001596"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-25753"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202204-3141"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2022-04-13T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2022-28484"
      },
      {
        "date": "2022-04-12T00:00:00",
        "db": "VULMON",
        "id": "CVE-2022-25753"
      },
      {
        "date": "2022-04-26T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2022-001596"
      },
      {
        "date": "2022-04-12T09:15:14.700000",
        "db": "NVD",
        "id": "CVE-2022-25753"
      },
      {
        "date": "2022-04-12T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202204-3141"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2022-04-13T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2022-28484"
      },
      {
        "date": "2022-04-19T00:00:00",
        "db": "VULMON",
        "id": "CVE-2022-25753"
      },
      {
        "date": "2022-04-26T09:01:00",
        "db": "JVNDB",
        "id": "JVNDB-2022-001596"
      },
      {
        "date": "2022-04-19T18:11:33.317000",
        "db": "NVD",
        "id": "CVE-2022-25753"
      },
      {
        "date": "2022-04-20T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202204-3141"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202204-3141"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "plural \u00a0SCALANCE\u00a0 Out-of-bounds write vulnerabilities in the product",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-001596"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "buffer error",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202204-3141"
      }
    ],
    "trust": 0.6
  }
}

var-202107-1608
Vulnerability from variot

Affected devices contain a vulnerability that allows an unauthenticated attacker to trigger a denial-of-service condition. The vulnerability can be triggered if a large amount of DCP reset packets are sent to the device. Multiple Siemens products contain vulnerabilities in resource allocation without restrictions or throttling.Service operation interruption (DoS) It may be in a state. Pillow is a Python-based image processing library. There is currently no information about this vulnerability, please feel free to follow CNNVD or manufacturer announcements. Siemens SCALANCE S602是德国西门子(Siemens)公司的一款工业安全设备. Siemens多款产品 存在安全漏洞,该漏洞允许攻击者执行拒绝服务攻击。以下产品和版本受到影响:Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller (All versions), Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200 (All versions), Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P (All versions), RUGGEDCOM RM1224 (All Versions < 6.4), SCALANCE M-800 (All Versions < 6.4), SCALANCE S615 (All Versions < 6.4), SCALANCE W1700 IEEE 802.11ac (All versions), SCALANCE W700 IEEE 802.11n (All versions), SCALANCE X200-4 P IRT (All Versions < V5.5.0), SCALANCE X201-3P IRT (All Versions < V5.5.0), SCALANCE X201-3P IRT PRO (All Versions < V5.5.0), SCALANCE X202-2 IRT (All Versions < V5.5.0), SCALANCE X202-2P IRT (incl. SIPLUS NET variant) (All Versions < V5.5.0), SCALANCE X202-2P IRT PRO (All Versions < V5.5.0), SCALANCE X204 IRT (All Versions < V5.5.0), SCALANCE X204 IRT PRO (All Versions < V5.5.0), SCALANCE X204-2 (incl. SIPLUS NET variant) (All versions), SCALANCE X204-2FM (All versions), SCALANCE X204-2LD (incl. SIPLUS NET variant) (All versions), SCALANCE X204-2LD TS (All versions), SCALANCE X204-2TS (All versions), SCALANCE X206-1 (All versions), SCALANCE X206-1LD (incl. SIPLUS NET variant) (All versions), SCALANCE X208 (incl. SIPLUS NET variant) (All versions), SCALANCE X208PRO (All versions), SCALANCE X212-2 (All versions), SCALANCE X212-2LD (All versions), SCALANCE X216 (All versions), SCALANCE X224 (All versions), SCALANCE X302-7EEC (All versions), SCALANCE X304-2FE (All versions), SCALANCE X306-1LDFE (All versions), SCALANCE X307-2EEC (All versions), SCALANCE X307-3 (All versions), SCALANCE X307-3LD (All versions), SCALANCE X308-2 (incl. SIPLUS NET variant) (All versions), SCALANCE X308-2LD (All versions), SCALANCE X308-2LH (All versions), SCALANCE X308-2LH+ (All versions), SCALANCE X308-2M (All versions), SCALANCE X308-2M POE (All versions), SCALANCE X308-2M TS (All versions), SCALANCE X310 (All versions), SCALANCE X310FE (All versions), SCALANCE X320-1FE (All versions), SCALANCE X320-3LDFE (All versions), SCALANCE XB-200 (All versions), SCALANCE XC-200 (All versions), SCALANCE XF-200BA (All versions), SCALANCE XF201-3P IRT (All Versions < V5.5.0), SCALANCE XF202-2P IRT (All Versions < V5.5.0), SCALANCE XF204 (All versions), SCALANCE XF204 IRT (All Versions < V5.5.0), SCALANCE XF204-2 (incl. SIPLUS NET variant) (All versions), SCALANCE XF204-2BA IRT (All Versions < V5.5.0), SCALANCE XF206-1 (All versions), SCALANCE XF208 (All versions), SCALANCE XM400 (All versions < V6.3.1), SCALANCE XP-200 (All versions), SCALANCE XR-300WG (All versions), SCALANCE XR324-12M (All versions), SCALANCE XR324-12M TS (All versions), SCALANCE XR324-4M EEC (All versions), SCALANCE XR324-4M POE (All versions), SCALANCE XR324-4M POE TS (All versions), SCALANCE XR500 (All versions < V6.3.1), SIMATIC CFU PA (All versions), SIMATIC IE/PB-LINK V3 (All versions), SIMATIC MV500 family (All versions < V3.0), SIMATIC NET CM 1542-1 (All versions), SIMATIC NET CP1616/CP1604 (All Versions >= V2.7), SIMATIC NET CP1626 (All versions), SIMATIC NET DK-16xx PN IO (All Versions >= V2.7), SIMATIC PROFINET Driver (All versions), SIMATIC Power Line Booster PLB, Base Module (MLFB: 6ES7972-5AA10-0AB0) (All versions), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All Versions < V4.5), SIMOCODE proV Ethernet/IP (All versions < V1.1.3), SIMOCODE proV PROFINET (All versions < V2.1.3), SOFTNET-IE PNIO (All versions)

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202107-1608",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "scalance xf-200ba",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.3"
      },
      {
        "model": "scalance x308-2",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "simatic ie\\/pb-link v3",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "ek-ertec 200 evaulation kit",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xp-200",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.3"
      },
      {
        "model": "scalance x302-7eec",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance x204 irt",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.5.0"
      },
      {
        "model": "scalance x204-2ld",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "simatic power line booster plb",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance x208",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xr324-12m",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance s615",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "6.4"
      },
      {
        "model": "simatic net cp1604",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2.7"
      },
      {
        "model": "scalance x308-2m poe",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance x308-2lh\\+",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance x304-2fe",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xr-300wg",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.3"
      },
      {
        "model": "scalance x320-1fe",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance m-800",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "6.4"
      },
      {
        "model": "scalance x307-3",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance x202-2p irt pro",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.5.0"
      },
      {
        "model": "scalance x308-2ld",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "ruggedcom rm1224",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "6.4"
      },
      {
        "model": "scalance x308-2m",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance x204-2ts",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "simatic s7-1200",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.5"
      },
      {
        "model": "simatic cfu pa",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance x224",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xm400",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "6.3.1"
      },
      {
        "model": "scalance x306-1ldfe",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance x200-4 p irt",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.5.0"
      },
      {
        "model": "scalance xf201-3p irt",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.5.0"
      },
      {
        "model": "simocode prov ethernet\\/ip",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "1.1.3"
      },
      {
        "model": "scalance x307-3ld",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "softnet-ie pnio",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xc-200",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.3"
      },
      {
        "model": "scalance w1700",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance x204-2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance x212-2ld",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance x308-2m ts",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "simatic net cm 1542-1",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance x201-3p irt pro",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.5.0"
      },
      {
        "model": "scalance x308-2lh",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "simatic net cp1616",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2.7"
      },
      {
        "model": "scalance xr324-4m poe",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "simatic net cp1626",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xf204-2ba irt",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.5.0"
      },
      {
        "model": "scalance x212-2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance x201-3p irt",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.5.0"
      },
      {
        "model": "scalance w700",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xf206-1",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "dk standard ethernet controller evaluation kit",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "simatic profinet driver",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2.3"
      },
      {
        "model": "scalance xf204 irt",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.5.0"
      },
      {
        "model": "scalance x204-2ld ts",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xf204",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "simocode prov profinet",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2.1.3"
      },
      {
        "model": "ek-ertec 200p evaluation kit",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.7"
      },
      {
        "model": "scalance x202-2 irt",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.5.0"
      },
      {
        "model": "scalance xr500",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "6.3.1"
      },
      {
        "model": "scalance x307-2eec",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance x310fe",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance x204-2fm",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance x310",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xf204-2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xr324-4m poe ts",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xr324-4m eec",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance x206-1",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "simatic mv500",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "3.0"
      },
      {
        "model": "scalance x320-3ldfe",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xf208",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xf202-2p irt",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.5.0"
      },
      {
        "model": "simatic net dk-16xx pn io",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2.7"
      },
      {
        "model": "scalance xr324-12m ts",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance x216",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance x204 irt pro",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.5.0"
      },
      {
        "model": "scalance xb-200",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.3"
      },
      {
        "model": "scalance x208pro",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance x206-1ld",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance x200-4p irt",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "dk standard ethernet controller evaluation kit",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance w1700",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance s615",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "ek-ertec 200p evaluation kit",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance x201-3p irt",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "ek-ertec 200 evaluation kit",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance w700",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance m-800",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "ruggedcom rm1224",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-010133"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-28400"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:dk_standard_ethernet_controller_evaluation_kit_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:dk_standard_ethernet_controller_evaluation_kit:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:ek-ertec_200_evaulation_kit_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:ek-ertec_200_evaulation_kit:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:ek-ertec_200p_evaluation_kit_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.7",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:ek-ertec_200p_evaluation_kit:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:ruggedcom_rm1224_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "6.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:ruggedcom_rm1224:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_m-800_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "6.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_m-800:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_s615_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "6.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_s615:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_w700_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_w700:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_w1700_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_w1700:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x200-4_p_irt_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.5.0",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x200-4_p_irt:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x201-3p_irt_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.5.0",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x201-3p_irt:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x201-3p_irt_pro_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.5.0",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x201-3p_irt_pro:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x202-2_irt_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.5.0",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x202-2_irt:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x202-2p_irt_pro_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.5.0",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x202-2p_irt_pro:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x204_irt_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.5.0",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x204_irt:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x204_irt_pro_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.5.0",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x204_irt_pro:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x204-2_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x204-2_:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x204-2fm_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x204-2fm:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x204-2ld_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x204-2ld:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x204-2ld_ts_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x204-2ld_ts:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x204-2ts_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x204-2ts:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x206-1_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x206-1:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x206-1ld_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x206-1ld:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x208_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x208:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x208pro_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x208pro:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x212-2_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x212-2:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x212-2ld_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x212-2ld:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x216_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x216:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x224_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x224:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x302-7eec_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x302-7eec:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x304-2fe_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x304-2fe:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x306-1ldfe_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x306-1ldfe:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x307-2eec_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x307-2eec:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x307-3_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x307-3:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x307-3ld_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x307-3ld:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x308-2_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x308-2:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x308-2ld_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x308-2ld:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x308-2lh_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x308-2lh:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x308-2lh\\+_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x308-2lh\\+:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x308-2m_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x308-2m:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x308-2m_poe_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x308-2m_poe:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x308-2m_ts_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x308-2m_ts:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x310_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x310:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x310fe_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x310fe:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x320-1fe_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x320-1fe:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x320-3ldfe_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x320-3ldfe:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xb-200_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.3",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xb-200:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xc-200_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.3",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xc-200:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xf201-3p_irt_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.5.0",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xf201-3p_irt:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xf202-2p_irt_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.5.0",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xf202-2p_irt:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xf204_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xf204:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xf204_irt_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.5.0",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xf204_irt:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xf204-2_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xf204-2_:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xf204-2ba_irt_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.5.0",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xf204-2ba_irt:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xf206-1_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xf206-1:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xf208_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xf208:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xf-200ba_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.3",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xf-200ba:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xm400_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "6.3.1",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xm400:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xp-200_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.3",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xp-200:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xr324-4m_eec_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xr324-4m_eec:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xr324-4m_poe_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xr324-4m_poe:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xr324-4m_poe_ts_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xr324-4m_poe_ts:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xr324-12m_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xr324-12m:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xr324-12m_ts_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xr324-12m_ts:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xr500_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "6.3.1",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xr500:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xr-300wg_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.3",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xr-300wg:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_cfu_pa_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_cfu_pa:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_ie\\/pb-link_v3_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_ie\\/pb-link_v3:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_mv500_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "3.0",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_mv500:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_net_cm_1542-1_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_net_cm_1542-1:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_net_cp1616_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndIncluding": "2.7",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_net_cp1616:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_net_cp1604_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndIncluding": "2.7",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_net_cp1604:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_net_cp1626_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_net_cp1626:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [],
            "cpe_match": [
              {
                "cpe23Uri": "cpe:2.3:a:siemens:simatic_net_dk-16xx_pn_io:*:*:*:*:*:*:*:*",
                "cpe_name": [],
                "versionEndIncluding": "2.7",
                "vulnerable": true
              }
            ],
            "operator": "OR"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_power_line_booster_plb_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_power_line_booster_plb:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_profinet_driver_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "2.3",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_profinet_driver:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simatic_s7-1200_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simatic_s7-1200:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simocode_prov_ethernet\\/ip_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "1.1.3",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simocode_prov_ethernet\\/ip:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:simocode_prov_profinet_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "2.1.3",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:simocode_prov_profinet:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:softnet-ie_pnio_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:softnet-ie_pnio:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2020-28400"
      }
    ]
  },
  "credits": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/credits#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Siemens reported this vulnerability to CISA.",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202107-901"
      }
    ],
    "trust": 0.6
  },
  "cve": "CVE-2020-28400",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "acInsufInfo": false,
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "NVD",
            "availabilityImpact": "PARTIAL",
            "baseScore": 5.0,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 10.0,
            "impactScore": 2.9,
            "integrityImpact": "NONE",
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "severity": "MEDIUM",
            "trust": 1.0,
            "userInteractionRequired": false,
            "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
            "version": "2.0"
          },
          {
            "acInsufInfo": null,
            "accessComplexity": "Low",
            "accessVector": "Network",
            "authentication": "None",
            "author": "NVD",
            "availabilityImpact": "Partial",
            "baseScore": 5.0,
            "confidentialityImpact": "None",
            "exploitabilityScore": null,
            "id": "CVE-2020-28400",
            "impactScore": null,
            "integrityImpact": "None",
            "obtainAllPrivilege": null,
            "obtainOtherPrivilege": null,
            "obtainUserPrivilege": null,
            "severity": "Medium",
            "trust": 0.8,
            "userInteractionRequired": null,
            "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "NVD",
            "availabilityImpact": "HIGH",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 3.9,
            "impactScore": 3.6,
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 2.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 7.5,
            "baseSeverity": "High",
            "confidentialityImpact": "None",
            "exploitabilityScore": null,
            "id": "CVE-2020-28400",
            "impactScore": null,
            "integrityImpact": "None",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "NVD",
            "id": "CVE-2020-28400",
            "trust": 1.8,
            "value": "HIGH"
          },
          {
            "author": "productcert@siemens.com",
            "id": "CVE-2020-28400",
            "trust": 1.0,
            "value": "HIGH"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202104-975",
            "trust": 0.6,
            "value": "MEDIUM"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202107-901",
            "trust": 0.6,
            "value": "HIGH"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-010133"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202104-975"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202107-901"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-28400"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-28400"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Affected devices contain a vulnerability that allows an unauthenticated attacker to trigger a denial-of-service condition. The vulnerability can be triggered if a large amount of DCP reset packets are sent to the device. Multiple Siemens products contain vulnerabilities in resource allocation without restrictions or throttling.Service operation interruption (DoS) It may be in a state. Pillow is a Python-based image processing library. \nThere is currently no information about this vulnerability, please feel free to follow CNNVD or manufacturer announcements. Siemens SCALANCE S602\u662f\u5fb7\u56fd\u897f\u95e8\u5b50\uff08Siemens\uff09\u516c\u53f8\u7684\u4e00\u6b3e\u5de5\u4e1a\u5b89\u5168\u8bbe\u5907. \nSiemens\u591a\u6b3e\u4ea7\u54c1 \u5b58\u5728\u5b89\u5168\u6f0f\u6d1e\uff0c\u8be5\u6f0f\u6d1e\u5141\u8bb8\u653b\u51fb\u8005\u6267\u884c\u62d2\u7edd\u670d\u52a1\u653b\u51fb\u3002\u4ee5\u4e0b\u4ea7\u54c1\u548c\u7248\u672c\u53d7\u5230\u5f71\u54cd\uff1aDevelopment/Evaluation Kits for PROFINET IO\uff1a DK Standard Ethernet Controller (All versions), Development/Evaluation Kits for PROFINET IO\uff1a EK-ERTEC 200 (All versions), Development/Evaluation Kits for PROFINET IO\uff1a EK-ERTEC 200P (All versions), RUGGEDCOM RM1224 (All Versions \uff1c 6.4), SCALANCE M-800 (All Versions \uff1c 6.4), SCALANCE S615 (All Versions \uff1c 6.4), SCALANCE W1700 IEEE 802.11ac (All versions), SCALANCE W700 IEEE 802.11n (All versions), SCALANCE X200-4 P IRT (All Versions \uff1c V5.5.0), SCALANCE X201-3P IRT (All Versions \uff1c V5.5.0), SCALANCE X201-3P IRT PRO (All Versions \uff1c V5.5.0), SCALANCE X202-2 IRT (All Versions \uff1c V5.5.0), SCALANCE X202-2P IRT (incl. SIPLUS NET variant) (All Versions \uff1c V5.5.0), SCALANCE X202-2P IRT PRO (All Versions \uff1c V5.5.0), SCALANCE X204 IRT (All Versions \uff1c V5.5.0), SCALANCE X204 IRT PRO (All Versions \uff1c V5.5.0), SCALANCE X204-2 (incl. SIPLUS NET variant) (All versions), SCALANCE X204-2FM (All versions), SCALANCE X204-2LD (incl. SIPLUS NET variant) (All versions), SCALANCE X204-2LD TS (All versions), SCALANCE X204-2TS (All versions), SCALANCE X206-1 (All versions), SCALANCE X206-1LD (incl. SIPLUS NET variant) (All versions), SCALANCE X208 (incl. SIPLUS NET variant) (All versions), SCALANCE X208PRO (All versions), SCALANCE X212-2 (All versions), SCALANCE X212-2LD (All versions), SCALANCE X216 (All versions), SCALANCE X224 (All versions), SCALANCE X302-7EEC (All versions), SCALANCE X304-2FE (All versions), SCALANCE X306-1LDFE (All versions), SCALANCE X307-2EEC (All versions), SCALANCE X307-3 (All versions), SCALANCE X307-3LD (All versions), SCALANCE X308-2 (incl. SIPLUS NET variant) (All versions), SCALANCE X308-2LD (All versions), SCALANCE X308-2LH (All versions), SCALANCE X308-2LH+ (All versions), SCALANCE X308-2M (All versions), SCALANCE X308-2M POE (All versions), SCALANCE X308-2M TS (All versions), SCALANCE X310 (All versions), SCALANCE X310FE (All versions), SCALANCE X320-1FE (All versions), SCALANCE X320-3LDFE (All versions), SCALANCE XB-200 (All versions), SCALANCE XC-200 (All versions), SCALANCE XF-200BA (All versions), SCALANCE XF201-3P IRT (All Versions \uff1c V5.5.0), SCALANCE XF202-2P IRT (All Versions \uff1c V5.5.0), SCALANCE XF204 (All versions), SCALANCE XF204 IRT (All Versions \uff1c V5.5.0), SCALANCE XF204-2 (incl. SIPLUS NET variant) (All versions), SCALANCE XF204-2BA IRT (All Versions \uff1c V5.5.0), SCALANCE XF206-1 (All versions), SCALANCE XF208 (All versions), SCALANCE XM400 (All versions \uff1c V6.3.1), SCALANCE XP-200 (All versions), SCALANCE XR-300WG (All versions), SCALANCE XR324-12M (All versions), SCALANCE XR324-12M TS (All versions), SCALANCE XR324-4M EEC (All versions), SCALANCE XR324-4M POE (All versions), SCALANCE XR324-4M POE TS (All versions), SCALANCE XR500 (All versions \uff1c V6.3.1), SIMATIC CFU PA (All versions), SIMATIC IE/PB-LINK V3 (All versions), SIMATIC MV500 family (All versions \uff1c V3.0), SIMATIC NET CM 1542-1 (All versions), SIMATIC NET CP1616/CP1604 (All Versions \uff1e= V2.7), SIMATIC NET CP1626 (All versions), SIMATIC NET DK-16xx PN IO (All Versions \uff1e= V2.7), SIMATIC PROFINET Driver (All versions), SIMATIC Power Line Booster PLB, Base Module (MLFB\uff1a 6ES7972-5AA10-0AB0) (All versions), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All Versions \uff1c V4.5), SIMOCODE proV Ethernet/IP (All versions \uff1c V1.1.3), SIMOCODE proV PROFINET (All versions \uff1c V2.1.3), SOFTNET-IE PNIO (All versions)",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2020-28400"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-010133"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202104-975"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202107-901"
      },
      {
        "db": "VULMON",
        "id": "CVE-2020-28400"
      }
    ],
    "trust": 2.79
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2020-28400",
        "trust": 3.3
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-21-194-03",
        "trust": 2.4
      },
      {
        "db": "SIEMENS",
        "id": "SSA-599968",
        "trust": 1.7
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-010133",
        "trust": 0.8
      },
      {
        "db": "CS-HELP",
        "id": "SB2021041363",
        "trust": 0.6
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202104-975",
        "trust": 0.6
      },
      {
        "db": "AUSCERT",
        "id": "ESB-2021.2401",
        "trust": 0.6
      },
      {
        "db": "CS-HELP",
        "id": "SB2021071416",
        "trust": 0.6
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202107-901",
        "trust": 0.6
      },
      {
        "db": "VULMON",
        "id": "CVE-2020-28400",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "VULMON",
        "id": "CVE-2020-28400"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-010133"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202104-975"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202107-901"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-28400"
      }
    ]
  },
  "id": "VAR-202107-1608",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "VARIoT devices database",
        "id": null
      }
    ],
    "trust": 0.544597090967742
  },
  "last_update_date": "2024-06-11T21:23:54.270000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "SSA-599968",
        "trust": 0.8,
        "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-599968.pdf"
      },
      {
        "title": "Siemens Various product security vulnerabilities",
        "trust": 0.6,
        "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=156594"
      },
      {
        "title": "Siemens Security Advisories: Siemens Security Advisory",
        "trust": 0.1,
        "url": "https://vulmon.com/vendoradvisory?qidtp=siemens_security_advisories\u0026qid=77fc0ba2dcd8966c9a1f7eb47b8603ca"
      }
    ],
    "sources": [
      {
        "db": "VULMON",
        "id": "CVE-2020-28400"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-010133"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202107-901"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-770",
        "trust": 1.0
      },
      {
        "problemtype": "Allocation of resources without limits or throttling (CWE-770) [NVD evaluation ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-010133"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-28400"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.2,
        "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-194-03"
      },
      {
        "trust": 1.7,
        "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-599968.pdf"
      },
      {
        "trust": 1.0,
        "url": "https://cert-portal.siemens.com/productcert/html/ssa-599968.html"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2020-28400"
      },
      {
        "trust": 0.8,
        "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-194-03"
      },
      {
        "trust": 0.6,
        "url": "https://www.cybersecurity-help.cz/vdb/sb2021041363"
      },
      {
        "trust": 0.6,
        "url": "https://vigilance.fr/vulnerability/siemens-ruggedcom-simatic-denial-of-service-via-profinet-dcp-reset-35890"
      },
      {
        "trust": 0.6,
        "url": "https://www.cybersecurity-help.cz/vdb/sb2021071416"
      },
      {
        "trust": 0.6,
        "url": "https://www.auscert.org.au/bulletins/esb-2021.2401"
      },
      {
        "trust": 0.1,
        "url": "https://cwe.mitre.org/data/definitions/770.html"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov"
      },
      {
        "trust": 0.1,
        "url": "https://cert-portal.siemens.com/productcert/txt/ssa-599968.txt"
      }
    ],
    "sources": [
      {
        "db": "VULMON",
        "id": "CVE-2020-28400"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-010133"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202104-975"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202107-901"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-28400"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "VULMON",
        "id": "CVE-2020-28400"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-010133"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202104-975"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202107-901"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-28400"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2021-07-13T00:00:00",
        "db": "VULMON",
        "id": "CVE-2020-28400"
      },
      {
        "date": "2022-06-22T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2021-010133"
      },
      {
        "date": "2021-04-13T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202104-975"
      },
      {
        "date": "2021-07-13T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202107-901"
      },
      {
        "date": "2021-07-13T11:15:08.960000",
        "db": "NVD",
        "id": "CVE-2020-28400"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2021-07-13T00:00:00",
        "db": "VULMON",
        "id": "CVE-2020-28400"
      },
      {
        "date": "2022-06-22T02:38:00",
        "db": "JVNDB",
        "id": "JVNDB-2021-010133"
      },
      {
        "date": "2021-04-14T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202104-975"
      },
      {
        "date": "2022-04-13T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202107-901"
      },
      {
        "date": "2024-06-11T09:15:09.487000",
        "db": "NVD",
        "id": "CVE-2020-28400"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202107-901"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Vulnerability in limiting or non-slotting resource allocation in multiple Siemens products",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2021-010133"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "other",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202104-975"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202107-901"
      }
    ],
    "trust": 1.2
  }
}

var-202101-0138
Vulnerability from variot

A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions < V5.2.5), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.5.0). The vulnerability could allow an unauthenticated attacker to reboot the device over the network by using special urls from integrated web server of the affected products. SCALANCE X-200 and SCALANCE X-200IRT A vulnerability exists in the switch family regarding the lack of authentication for critical features.Denial of service (DoS) It may be put into a state. SCALANCE X is a switch used to connect industrial components, such as programmable logic controllers (plc) or human machine interfaces (HMIs)

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202101-0138",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "scalance xc216eec",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xb216",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xc206-2g poe eec",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xc216",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance x308-2lh\\+",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance x307-3",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xc206-2sfp g eec",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance x307-3ld",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xc224",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance x308-2m",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xc208g",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance x202-2pirt",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.5.0"
      },
      {
        "model": "scalance xf204-2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xc208g poe",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xc206-2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance x308-2ld",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance x200-4pirt",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.5.0"
      },
      {
        "model": "scalance xf201-3p irt",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xc216-4c",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xf204irt",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xb205-3ld",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xp216poe eec",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xc224-4c g \\",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xf206-1",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xc216-4c g eec",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xc206-2sfp g",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xp208poe eec",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance x320-1fe",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xf204 dna",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xp208 \\",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xf204-2ba dna",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance x202-2irt",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.5.0"
      },
      {
        "model": "scalance x310fe",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xf208",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance x308-2lh",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xc206-2sfp",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance x310",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance x320-3ldfe",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xb213-3ld",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance x308-2",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xc224-4c g",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xc224-4c g eec",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance x202-2pirt siplus net",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.5.0"
      },
      {
        "model": "scalance x308-2m ts",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xf204-2ba irt",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xc208g \\",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xc216-4c g \\",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xp208",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xp216",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xc206-2sfp g \\",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance x201-3pirt",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.5.0"
      },
      {
        "model": "scalance xb208",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xp216 \\",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xf204",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xb205-3",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xp216eec",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xc206-2g poe",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xb213-3",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xp208eec",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xc208eec",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance x204irt",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.5.0"
      },
      {
        "model": "scalance xc216-4c g",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xf202-2p irt",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xc208",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xc206-2sfp eec",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xc208g eec",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance x307-3ld",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance x201-3pirt",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance x200-4pirt",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance x202-2pirt",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance x204irt",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "siplus net scalance x202-2pirt",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance x308-2",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance x202-2irt",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance x308-2ld",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance x307-3",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance x-200irt switch family",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance switch family",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "x-200"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-02596"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-015540"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-15799"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x200-4pirt_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.5.0",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x200-4pirt:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x201-3pirt_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.5.0",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x201-3pirt:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x202-2irt_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.5.0",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x202-2irt:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x202-2pirt_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.5.0",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x202-2pirt:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x202-2pirt_siplus_net_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.5.0",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x202-2pirt_siplus_net:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x204irt_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.5.0",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x204irt:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x307-3_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x307-3:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x307-3ld_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x307-3ld:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x308-2_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x308-2:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x308-2ld_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x308-2ld:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x308-2lh_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x308-2lh:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x308-2lh\\+_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x308-2lh\\+:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x308-2m_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x308-2m:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x308-2m_ts_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x308-2m_ts:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x310_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x310:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x310fe_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x310fe:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x320-1fe_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x320-1fe:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x320-3ldfe_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x320-3ldfe:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xb205-3_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xb205-3:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xb205-3ld_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xb205-3ld:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xb208_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xb208:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xb213-3_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xb213-3:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xb213-3ld_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xb213-3ld:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xb216_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xb216:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xc206-2_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xc206-2:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xc206-2g_poe__firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xc206-2g_poe_:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xc206-2g_poe_eec_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xc206-2g_poe_eec:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xc206-2sfp_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xc206-2sfp:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xc206-2sfp_eec_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xc206-2sfp_eec:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xc206-2sfp_g_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xc206-2sfp_g:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xc206-2sfp_g_\\(e\\/ip\\)_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xc206-2sfp_g_\\(e\\/ip\\):-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xc206-2sfp_g_eec_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xc206-2sfp_g_eec:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xc208_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xc208:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xc208eec_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xc208eec:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xc208g_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xc208g:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xc208g_\\(e\\/ip\\)_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xc208g_\\(e\\/ip\\):-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xc208g_eec_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xc208g_eec:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xc208g_poe_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xc208g_poe:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xc216_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xc216:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xc216-4c_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xc216-4c:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xc216-4c_g_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xc216-4c_g:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xc216-4c_g_\\(e\\/ip\\)_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xc216-4c_g_\\(e\\/ip\\):-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xc216-4c_g_eec_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xc216-4c_g_eec:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xc216eec_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xc216eec:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xc224-4c_g__firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xc224-4c_g_:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xc224-4c_g_\\(e\\/ip\\)_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xc224-4c_g_\\(e\\/ip\\):-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xc224-4c_g_eec_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xc224-4c_g_eec:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xc224__firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xc224_:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xf201-3p_irt_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xf201-3p_irt:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xf202-2p_irt_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xf202-2p_irt:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xf204_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xf204:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xf204-2_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xf204-2:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xf204-2ba_dna_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xf204-2ba_dna:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xf204-2ba_irt_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xf204-2ba_irt:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xf204_dna_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xf204_dna:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xf204irt_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xf204irt:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xf206-1_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xf206-1:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xf208_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xf208:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xp208_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xp208:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xp208_\\(eip\\)_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xp208_\\(eip\\):-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xp208eec_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xp208eec:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xp208poe_eec_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xp208poe_eec:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xp216_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xp216:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xp216_\\(eip\\)_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xp216_\\(eip\\):-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xp216eec_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xp216eec:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xp216poe_eec_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xp216poe_eec:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2020-15799"
      }
    ]
  },
  "credits": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/credits#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Siemens reported these vulnerabilities to CISA.",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202101-856"
      }
    ],
    "trust": 0.6
  },
  "cve": "CVE-2020-15799",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "acInsufInfo": false,
            "accessComplexity": "MEDIUM",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "NVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 7.1,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 8.6,
            "impactScore": 6.9,
            "integrityImpact": "NONE",
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "severity": "HIGH",
            "trust": 1.0,
            "userInteractionRequired": true,
            "vectorString": "AV:N/AC:M/Au:N/C:N/I:N/A:C",
            "version": "2.0"
          },
          {
            "acInsufInfo": null,
            "accessComplexity": "Medium",
            "accessVector": "Network",
            "authentication": "None",
            "author": "NVD",
            "availabilityImpact": "Complete",
            "baseScore": 7.1,
            "confidentialityImpact": "None",
            "exploitabilityScore": null,
            "id": "CVE-2020-15799",
            "impactScore": null,
            "integrityImpact": "None",
            "obtainAllPrivilege": null,
            "obtainOtherPrivilege": null,
            "obtainUserPrivilege": null,
            "severity": "High",
            "trust": 0.8,
            "userInteractionRequired": null,
            "vectorString": "AV:N/AC:M/Au:N/C:N/I:N/A:C",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 7.8,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 10.0,
            "id": "CNVD-2021-02596",
            "impactScore": 6.9,
            "integrityImpact": "NONE",
            "severity": "HIGH",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "NVD",
            "availabilityImpact": "HIGH",
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 2.8,
            "impactScore": 3.6,
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 6.5,
            "baseSeverity": "Medium",
            "confidentialityImpact": "None",
            "exploitabilityScore": null,
            "id": "CVE-2020-15799",
            "impactScore": null,
            "integrityImpact": "None",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "Required",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "NVD",
            "id": "CVE-2020-15799",
            "trust": 1.8,
            "value": "MEDIUM"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2021-02596",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202101-856",
            "trust": 0.6,
            "value": "MEDIUM"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-02596"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-015540"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-15799"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202101-856"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions \u003c V5.2.5), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions \u003c V5.5.0). The vulnerability could allow an unauthenticated attacker to reboot the device over the network by using special urls from integrated web server of the affected products. SCALANCE X-200 and SCALANCE X-200IRT A vulnerability exists in the switch family regarding the lack of authentication for critical features.Denial of service (DoS) It may be put into a state. SCALANCE X is a switch used to connect industrial components, such as programmable logic controllers (plc) or human machine interfaces (HMIs)",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2020-15799"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-015540"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2021-02596"
      }
    ],
    "trust": 2.16
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2020-15799",
        "trust": 3.0
      },
      {
        "db": "SIEMENS",
        "id": "SSA-139628",
        "trust": 2.2
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-015540",
        "trust": 0.8
      },
      {
        "db": "CNVD",
        "id": "CNVD-2021-02596",
        "trust": 0.6
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-21-012-05",
        "trust": 0.6
      },
      {
        "db": "AUSCERT",
        "id": "ESB-2021.0127",
        "trust": 0.6
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202101-856",
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-02596"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-015540"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-15799"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202101-856"
      }
    ]
  },
  "id": "VAR-202101-0138",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-02596"
      }
    ],
    "trust": 1.2646204777777776
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "ICS"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-02596"
      }
    ]
  },
  "last_update_date": "2023-12-18T11:57:47.763000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "SSA-139628",
        "trust": 0.8,
        "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-139628.pdf"
      },
      {
        "title": "Patch for Scalance X Products key function certification missing vulnerability",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchinfo/show/244024"
      },
      {
        "title": "Multiple  Siemens SCALANCE Fixes for access control error vulnerabilities",
        "trust": 0.6,
        "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=139366"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-02596"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-015540"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202101-856"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-306",
        "trust": 1.0
      },
      {
        "problemtype": "Lack of authentication for important features (CWE-306) [NVD Evaluation ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-015540"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-15799"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.2,
        "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-139628.pdf"
      },
      {
        "trust": 1.4,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2020-15799"
      },
      {
        "trust": 0.6,
        "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-012-05"
      },
      {
        "trust": 0.6,
        "url": "https://www.auscert.org.au/bulletins/esb-2021.0127/"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-02596"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-015540"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-15799"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202101-856"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-02596"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-015540"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-15799"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202101-856"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2021-01-13T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2021-02596"
      },
      {
        "date": "2021-10-04T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2020-015540"
      },
      {
        "date": "2021-01-12T21:15:16.370000",
        "db": "NVD",
        "id": "CVE-2020-15799"
      },
      {
        "date": "2021-01-12T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202101-856"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2021-02-04T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2021-02596"
      },
      {
        "date": "2021-10-04T05:21:00",
        "db": "JVNDB",
        "id": "JVNDB-2020-015540"
      },
      {
        "date": "2022-07-28T14:34:20.493000",
        "db": "NVD",
        "id": "CVE-2020-15799"
      },
      {
        "date": "2021-09-15T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202101-856"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202101-856"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "SCALANCE\u00a0X-200\u00a0 and \u00a0SCALANCE\u00a0X-200IRT\u00a0 Vulnerability in lack of authentication for critical features in the switch family",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-015540"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "access control error",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202101-856"
      }
    ],
    "trust": 0.6
  }
}

var-202101-0139
Vulnerability from variot

A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions < V5.2.5), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.5.0), SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants) (All versions < V4.1.0). The webserver of the affected devices contains a vulnerability that may lead to a heap overflow condition. An attacker could cause this condition on the webserver by sending specially crafted requests. This could stop the webserver temporarily. SCALANCE X-200 and SCALANCE X-200IRT An out-of-bounds write vulnerability exists in the switch family.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. SCALANCE X is a switch used to connect industrial components, such as programmable logic controllers (plc) or human machine interfaces (HMIs)

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202101-0139",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "scalance xc216eec",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xb216",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xc206-2g poe eec",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xc216",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance x308-2lh\\+",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance x307-3",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xc206-2sfp g eec",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance x307-3ld",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xc224",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance x308-2m",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xc208g",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance x202-2pirt",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.5.0"
      },
      {
        "model": "scalance xf204-2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xc208g poe",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xc206-2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance x308-2ld",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance x200-4pirt",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.5.0"
      },
      {
        "model": "scalance xf201-3p irt",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xc216-4c",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xf204irt",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xb205-3ld",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xp216poe eec",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xc224-4c g \\",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xf206-1",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xc216-4c g eec",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xc206-2sfp g",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xp208poe eec",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance x320-1fe",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xf204 dna",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xp208 \\",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xf204-2ba dna",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance x202-2irt",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.5.0"
      },
      {
        "model": "scalance x310fe",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xf208",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance x308-2lh",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xc206-2sfp",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance x310",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance x320-3ldfe",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xb213-3ld",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance x308-2",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xc224-4c g",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xc224-4c g eec",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance x202-2pirt siplus net",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.5.0"
      },
      {
        "model": "scalance x308-2m ts",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance xf204-2ba irt",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xc208g \\",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xc216-4c g \\",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xp208",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xp216",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xc206-2sfp g \\",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance x201-3pirt",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.5.0"
      },
      {
        "model": "scalance xb208",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xp216 \\",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xf204",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xb205-3",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xp216eec",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xc206-2g poe",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xb213-3",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xp208eec",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xc208eec",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance x204irt",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.5.0"
      },
      {
        "model": "scalance xc216-4c g",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xf202-2p irt",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xc208",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xc206-2sfp eec",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance xc208g eec",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2.5"
      },
      {
        "model": "scalance x200-4pirt",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance x307-3ld",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance x202-2pirt",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance x308-2",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "siplus net scalance x202-2pirt",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance x204irt",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance x307-3",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance x201-3pirt",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance x202-2irt",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance x308-2ld",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance x-200irt switch family",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance switch family",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "x-200"
      },
      {
        "model": "scalance switch family",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "x-300x408\u003cv4.1.0"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-02595"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-015534"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-15800"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x200-4pirt_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.5.0",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x200-4pirt:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x201-3pirt_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.5.0",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x201-3pirt:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x202-2irt_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.5.0",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x202-2irt:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x202-2pirt_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.5.0",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x202-2pirt:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x202-2pirt_siplus_net_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.5.0",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x202-2pirt_siplus_net:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x204irt_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.5.0",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x204irt:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x307-3_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x307-3:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x307-3ld_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x307-3ld:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x308-2_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x308-2:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x308-2ld_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x308-2ld:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x308-2lh_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x308-2lh:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x308-2lh\\+_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x308-2lh\\+:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x308-2m_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x308-2m:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x308-2m_ts_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x308-2m_ts:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x310_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x310:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x310fe_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x310fe:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x320-1fe_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x320-1fe:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x320-3ldfe_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x320-3ldfe:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xb205-3_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xb205-3:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xb205-3ld_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xb205-3ld:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xb208_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xb208:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xb213-3_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xb213-3:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xb213-3ld_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xb213-3ld:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xb216_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xb216:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xc206-2_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xc206-2:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xc206-2g_poe__firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xc206-2g_poe_:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xc206-2g_poe_eec_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xc206-2g_poe_eec:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xc206-2sfp_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xc206-2sfp:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xc206-2sfp_eec_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xc206-2sfp_eec:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xc206-2sfp_g_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xc206-2sfp_g:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xc206-2sfp_g_\\(e\\/ip\\)_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xc206-2sfp_g_\\(e\\/ip\\):-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xc206-2sfp_g_eec_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xc206-2sfp_g_eec:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xc208_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xc208:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xc208eec_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xc208eec:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xc208g_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xc208g:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xc208g_\\(e\\/ip\\)_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xc208g_\\(e\\/ip\\):-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xc208g_eec_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xc208g_eec:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xc208g_poe_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xc208g_poe:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xc216_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xc216:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xc216-4c_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xc216-4c:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xc216-4c_g_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xc216-4c_g:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xc216-4c_g_\\(e\\/ip\\)_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xc216-4c_g_\\(e\\/ip\\):-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xc216-4c_g_eec_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xc216-4c_g_eec:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xc216eec_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xc216eec:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xc224-4c_g__firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xc224-4c_g_:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xc224-4c_g_\\(e\\/ip\\)_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xc224-4c_g_\\(e\\/ip\\):-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xc224-4c_g_eec_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xc224-4c_g_eec:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xc224__firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xc224_:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xf201-3p_irt_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xf201-3p_irt:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xf202-2p_irt_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xf202-2p_irt:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xf204_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xf204:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xf204-2_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xf204-2:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xf204-2ba_dna_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xf204-2ba_dna:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xf204-2ba_irt_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xf204-2ba_irt:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xf204_dna_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xf204_dna:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xf204irt_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xf204irt:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xf206-1_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xf206-1:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xf208_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xf208:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xp208_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xp208:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xp208_\\(eip\\)_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xp208_\\(eip\\):-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xp208eec_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xp208eec:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xp208poe_eec_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xp208poe_eec:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xp216_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xp216:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xp216_\\(eip\\)_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xp216_\\(eip\\):-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xp216eec_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xp216eec:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xp216poe_eec_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "5.2.5",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xp216poe_eec:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2020-15800"
      }
    ]
  },
  "credits": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/credits#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Siemens reported these vulnerabilities to CISA.",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202101-915"
      }
    ],
    "trust": 0.6
  },
  "cve": "CVE-2020-15800",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "acInsufInfo": false,
            "accessComplexity": "MEDIUM",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "NVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 9.3,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 8.6,
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "severity": "HIGH",
            "trust": 1.0,
            "userInteractionRequired": false,
            "vectorString": "AV:N/AC:M/Au:N/C:C/I:C/A:C",
            "version": "2.0"
          },
          {
            "acInsufInfo": null,
            "accessComplexity": "Medium",
            "accessVector": "Network",
            "authentication": "None",
            "author": "NVD",
            "availabilityImpact": "Complete",
            "baseScore": 9.3,
            "confidentialityImpact": "Complete",
            "exploitabilityScore": null,
            "id": "CVE-2020-15800",
            "impactScore": null,
            "integrityImpact": "Complete",
            "obtainAllPrivilege": null,
            "obtainOtherPrivilege": null,
            "obtainUserPrivilege": null,
            "severity": "High",
            "trust": 0.8,
            "userInteractionRequired": null,
            "vectorString": "AV:N/AC:M/Au:N/C:C/I:C/A:C",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 7.8,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 10.0,
            "id": "CNVD-2021-02595",
            "impactScore": 6.9,
            "integrityImpact": "NONE",
            "severity": "HIGH",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "NVD",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 9.8,
            "baseSeverity": "Critical",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "CVE-2020-15800",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "NVD",
            "id": "CVE-2020-15800",
            "trust": 1.8,
            "value": "CRITICAL"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2021-02595",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202101-915",
            "trust": 0.6,
            "value": "CRITICAL"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-02595"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-015534"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-15800"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202101-915"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions \u003c V5.2.5), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions \u003c V5.5.0), SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants) (All versions \u003c V4.1.0). The webserver of the affected devices contains a vulnerability that may lead to a heap overflow condition. An attacker could cause this condition on the webserver by sending specially crafted requests. This could stop the webserver temporarily. SCALANCE X-200 and SCALANCE X-200IRT An out-of-bounds write vulnerability exists in the switch family.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. SCALANCE X is a switch used to connect industrial components, such as programmable logic controllers (plc) or human machine interfaces (HMIs)",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2020-15800"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-015534"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2021-02595"
      }
    ],
    "trust": 2.16
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2020-15800",
        "trust": 3.0
      },
      {
        "db": "SIEMENS",
        "id": "SSA-139628",
        "trust": 2.2
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-015534",
        "trust": 0.8
      },
      {
        "db": "CNVD",
        "id": "CNVD-2021-02595",
        "trust": 0.6
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-21-012-05",
        "trust": 0.6
      },
      {
        "db": "AUSCERT",
        "id": "ESB-2021.0127",
        "trust": 0.6
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202101-915",
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-02595"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-015534"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-15800"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202101-915"
      }
    ]
  },
  "id": "VAR-202101-0139",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-02595"
      }
    ],
    "trust": 1.2646204777777776
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "ICS"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-02595"
      }
    ]
  },
  "last_update_date": "2023-12-18T11:57:47.704000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "SSA-139628",
        "trust": 0.8,
        "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-139628.pdf"
      },
      {
        "title": "Patch for Scalance X Products heap buffer overflow vulnerability",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchinfo/show/244021"
      },
      {
        "title": "Siemens SCALANCE X-200IRT Buffer error vulnerability fix",
        "trust": 0.6,
        "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=138843"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-02595"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-015534"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202101-915"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-122",
        "trust": 1.0
      },
      {
        "problemtype": "Out-of-bounds writing (CWE-787) [NVD Evaluation ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-015534"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-15800"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.2,
        "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-139628.pdf"
      },
      {
        "trust": 1.4,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2020-15800"
      },
      {
        "trust": 0.6,
        "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-012-05"
      },
      {
        "trust": 0.6,
        "url": "https://www.auscert.org.au/bulletins/esb-2021.0127/"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-02595"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-015534"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-15800"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202101-915"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-02595"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-015534"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-15800"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202101-915"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2021-01-13T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2021-02595"
      },
      {
        "date": "2021-10-01T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2020-015534"
      },
      {
        "date": "2021-01-12T21:15:16.480000",
        "db": "NVD",
        "id": "CVE-2020-15800"
      },
      {
        "date": "2021-01-12T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202101-915"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2021-02-04T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2021-02595"
      },
      {
        "date": "2021-10-01T08:52:00",
        "db": "JVNDB",
        "id": "JVNDB-2020-015534"
      },
      {
        "date": "2022-07-01T18:53:35.470000",
        "db": "NVD",
        "id": "CVE-2020-15800"
      },
      {
        "date": "2021-09-15T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202101-915"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202101-915"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "SCALANCE\u00a0X-200\u00a0 and \u00a0SCALANCE\u00a0X-200IRT\u00a0 Out-of-bounds write vulnerability in switch family",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-015534"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "buffer error",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202101-915"
      }
    ],
    "trust": 0.6
  }
}

var-202204-0496
Vulnerability from variot

A vulnerability has been identified in SCALANCE X302-7 EEC (230V), SCALANCE X302-7 EEC (230V, coated), SCALANCE X302-7 EEC (24V), SCALANCE X302-7 EEC (24V, coated), SCALANCE X302-7 EEC (2x 230V), SCALANCE X302-7 EEC (2x 230V, coated), SCALANCE X302-7 EEC (2x 24V), SCALANCE X302-7 EEC (2x 24V, coated), SCALANCE X304-2FE, SCALANCE X306-1LD FE, SCALANCE X307-2 EEC (230V), SCALANCE X307-2 EEC (230V, coated), SCALANCE X307-2 EEC (24V), SCALANCE X307-2 EEC (24V, coated), SCALANCE X307-2 EEC (2x 230V), SCALANCE X307-2 EEC (2x 230V, coated), SCALANCE X307-2 EEC (2x 24V), SCALANCE X307-2 EEC (2x 24V, coated), SCALANCE X307-3, SCALANCE X307-3, SCALANCE X307-3LD, SCALANCE X307-3LD, SCALANCE X308-2, SCALANCE X308-2, SCALANCE X308-2LD, SCALANCE X308-2LD, SCALANCE X308-2LH, SCALANCE X308-2LH, SCALANCE X308-2LH+, SCALANCE X308-2LH+, SCALANCE X308-2M, SCALANCE X308-2M, SCALANCE X308-2M PoE, SCALANCE X308-2M PoE, SCALANCE X308-2M TS, SCALANCE X308-2M TS, SCALANCE X310, SCALANCE X310, SCALANCE X310FE, SCALANCE X310FE, SCALANCE X320-1 FE, SCALANCE X320-1-2LD FE, SCALANCE X408-2, SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M TS (24V), SCALANCE XR324-12M TS (24V), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M PoE (230V, ports on front), SCALANCE XR324-4M PoE (230V, ports on rear), SCALANCE XR324-4M PoE (24V, ports on front), SCALANCE XR324-4M PoE (24V, ports on rear), SCALANCE XR324-4M PoE TS (24V, ports on front), SIPLUS NET SCALANCE X308-2. The webserver of affected devices calculates session ids and nonces in an insecure manner. This could allow an unauthenticated remote attacker to brute-force session ids and hijack existing sessions. plural SCALANCE The product is vulnerable to the use of inadequate random values.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. SCALANCE X switches are used to connect industrial components such as programmable logic controllers (PLC) or human machine interfaces (HMI). SIPLUS extreme is designed for reliable operation under extreme conditions

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202204-0496",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "scalance xr324-4m eec",
        "scope": "lt",
        "trust": 1.6,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance xr324-4m poe",
        "scope": "lt",
        "trust": 1.6,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance xr324-4m poe ts",
        "scope": "lt",
        "trust": 1.6,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance xr324-12m",
        "scope": "lt",
        "trust": 1.6,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance xr324-12m ts",
        "scope": "lt",
        "trust": 1.6,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance x308-2m",
        "scope": "lt",
        "trust": 1.6,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance x307-3ld",
        "scope": "lt",
        "trust": 1.6,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance x304-2fe",
        "scope": "lt",
        "trust": 1.6,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance x310fe",
        "scope": "lt",
        "trust": 1.6,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance x308-2m ts",
        "scope": "lt",
        "trust": 1.6,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance x308-2ld",
        "scope": "lt",
        "trust": 1.6,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance x308-2lh",
        "scope": "lt",
        "trust": 1.6,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance x320-1fe",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance x307-3",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance x302-7eec",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance x320-1-2ldfe",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "siplus net scalance x308-2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance x408-2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance x308-2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance x306-1ldfe",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance x308-2m poe",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance x308-2lh\\+",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance x310",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance x307-2eec",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance x304-2fe",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance x307-3ld",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance x307-3",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance x308-2",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance x307-2eec",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance x308-2ld",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance x308-2lh+",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance x308-2lh",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance x306-1ldfe",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance x302-7eec",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance fe",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "x320-1\u003c4.1.4"
      },
      {
        "model": "scalance x320-1-2ld fe",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "x408-2\u003c4.1.4"
      },
      {
        "model": "siplus net scalance",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "x308-2\u003c4.1.4"
      },
      {
        "model": "scalance",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "x307-3\u003c4.1.4"
      },
      {
        "model": "scalance eec",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "x307-2\u003c4.1.4"
      },
      {
        "model": "scalance x306-1ld fe",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance eec",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "x302-7\u003c4.1.4"
      },
      {
        "model": "scalance",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "x310\u003c4.1.4"
      },
      {
        "model": "scalance x308-2m poe",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "x308-2\u003c4.1.4"
      },
      {
        "model": "scalance x308-2lh+",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.1.4"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-28485"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-001597"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-25752"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x302-7eec_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x302-7eec:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x304-2fe_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x304-2fe:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x306-1ldfe_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x306-1ldfe:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x307-2eec_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x307-2eec:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x307-3_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x307-3:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x307-3ld_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x307-3ld:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x308-2_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x308-2:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x308-2ld_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x308-2ld:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x308-2lh_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x308-2lh:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x308-2lh\\+_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x308-2lh\\+:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x308-2m_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x308-2m:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x308-2m_poe_firmware:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x308-2m_poe:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x308-2m_ts_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x308-2m_ts:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x310_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x310:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x310fe_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x310fe:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x320-1fe_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x320-1fe:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x320-1-2ldfe_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x320-1-2ldfe:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x408-2_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x408-2:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xr324-4m_eec_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xr324-4m_eec:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xr324-4m_poe_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xr324-4m_poe:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xr324-4m_poe_ts_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xr324-4m_poe_ts:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xr324-12m_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xr324-12m:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xr324-12m_ts_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xr324-12m_ts:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:siplus_net_scalance_x308-2_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:siplus_net_scalance_x308-2:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2022-25752"
      }
    ]
  },
  "cve": "CVE-2022-25752",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "acInsufInfo": false,
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "NVD",
            "availabilityImpact": "PARTIAL",
            "baseScore": 7.5,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "severity": "HIGH",
            "trust": 1.0,
            "userInteractionRequired": false,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          },
          {
            "acInsufInfo": null,
            "accessComplexity": "Low",
            "accessVector": "Network",
            "authentication": "None",
            "author": "NVD",
            "availabilityImpact": "Partial",
            "baseScore": 7.5,
            "confidentialityImpact": "Partial",
            "exploitabilityScore": null,
            "id": "CVE-2022-25752",
            "impactScore": null,
            "integrityImpact": "Partial",
            "obtainAllPrivilege": null,
            "obtainOtherPrivilege": null,
            "obtainUserPrivilege": null,
            "severity": "High",
            "trust": 0.9,
            "userInteractionRequired": null,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 10.0,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 10.0,
            "id": "CNVD-2022-28485",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "NVD",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 9.8,
            "baseSeverity": "Critical",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "CVE-2022-25752",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "NVD",
            "id": "CVE-2022-25752",
            "trust": 1.8,
            "value": "CRITICAL"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2022-28485",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202204-3140",
            "trust": 0.6,
            "value": "CRITICAL"
          },
          {
            "author": "VULMON",
            "id": "CVE-2022-25752",
            "trust": 0.1,
            "value": "HIGH"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-28485"
      },
      {
        "db": "VULMON",
        "id": "CVE-2022-25752"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-001597"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-25752"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202204-3140"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "A vulnerability has been identified in SCALANCE X302-7 EEC (230V), SCALANCE X302-7 EEC (230V, coated), SCALANCE X302-7 EEC (24V), SCALANCE X302-7 EEC (24V, coated), SCALANCE X302-7 EEC (2x 230V), SCALANCE X302-7 EEC (2x 230V, coated), SCALANCE X302-7 EEC (2x 24V), SCALANCE X302-7 EEC (2x 24V, coated), SCALANCE X304-2FE, SCALANCE X306-1LD FE, SCALANCE X307-2 EEC (230V), SCALANCE X307-2 EEC (230V, coated), SCALANCE X307-2 EEC (24V), SCALANCE X307-2 EEC (24V, coated), SCALANCE X307-2 EEC (2x 230V), SCALANCE X307-2 EEC (2x 230V, coated), SCALANCE X307-2 EEC (2x 24V), SCALANCE X307-2 EEC (2x 24V, coated), SCALANCE X307-3, SCALANCE X307-3, SCALANCE X307-3LD, SCALANCE X307-3LD, SCALANCE X308-2, SCALANCE X308-2, SCALANCE X308-2LD, SCALANCE X308-2LD, SCALANCE X308-2LH, SCALANCE X308-2LH, SCALANCE X308-2LH+, SCALANCE X308-2LH+, SCALANCE X308-2M, SCALANCE X308-2M, SCALANCE X308-2M PoE, SCALANCE X308-2M PoE, SCALANCE X308-2M TS, SCALANCE X308-2M TS, SCALANCE X310, SCALANCE X310, SCALANCE X310FE, SCALANCE X310FE, SCALANCE X320-1 FE, SCALANCE X320-1-2LD FE, SCALANCE X408-2, SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M TS (24V), SCALANCE XR324-12M TS (24V), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M PoE (230V, ports on front), SCALANCE XR324-4M PoE (230V, ports on rear), SCALANCE XR324-4M PoE (24V, ports on front), SCALANCE XR324-4M PoE (24V, ports on rear), SCALANCE XR324-4M PoE TS (24V, ports on front), SIPLUS NET SCALANCE X308-2. The webserver of affected devices calculates session ids and nonces in an insecure manner. This could allow an unauthenticated remote attacker to brute-force session ids and hijack existing sessions. plural  SCALANCE The product is vulnerable to the use of inadequate random values.Information is obtained, information is tampered with, and service is disrupted  (DoS) It may be put into a state. SCALANCE X switches are used to connect industrial components such as programmable logic controllers (PLC) or human machine interfaces (HMI). SIPLUS extreme is designed for reliable operation under extreme conditions",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2022-25752"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-001597"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2022-28485"
      },
      {
        "db": "VULMON",
        "id": "CVE-2022-25752"
      }
    ],
    "trust": 2.25
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2022-25752",
        "trust": 3.9
      },
      {
        "db": "SIEMENS",
        "id": "SSA-836527",
        "trust": 2.3
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-22-104-09",
        "trust": 0.9
      },
      {
        "db": "JVN",
        "id": "JVNVU91165555",
        "trust": 0.8
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-001597",
        "trust": 0.8
      },
      {
        "db": "CNVD",
        "id": "CNVD-2022-28485",
        "trust": 0.6
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202204-3140",
        "trust": 0.6
      },
      {
        "db": "VULMON",
        "id": "CVE-2022-25752",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-28485"
      },
      {
        "db": "VULMON",
        "id": "CVE-2022-25752"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-001597"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-25752"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202204-3140"
      }
    ]
  },
  "id": "VAR-202204-0496",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-28485"
      }
    ],
    "trust": 1.2919426426666667
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-28485"
      }
    ]
  },
  "last_update_date": "2023-12-18T11:56:14.809000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "SSA-836527",
        "trust": 0.8,
        "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-836527.pdf"
      },
      {
        "title": "Patch for Unknown Vulnerability in Siemens SCALANCE X-300 Switch Family Devices",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchinfo/show/329306"
      },
      {
        "title": "Multiple  Siemens Repair measures for product security feature vulnerabilities",
        "trust": 0.6,
        "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=190130"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-28485"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-001597"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202204-3140"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-330",
        "trust": 1.0
      },
      {
        "problemtype": "Use of insufficient random values (CWE-330) [NVD Evaluation ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-001597"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-25752"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.3,
        "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-836527.pdf"
      },
      {
        "trust": 0.9,
        "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-104-09"
      },
      {
        "trust": 0.8,
        "url": "https://jvn.jp/vu/jvnvu91165555/"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2022-25752"
      },
      {
        "trust": 0.6,
        "url": "https://cxsecurity.com/cveshow/cve-2022-25752/"
      },
      {
        "trust": 0.1,
        "url": "https://cwe.mitre.org/data/definitions/330.html"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-28485"
      },
      {
        "db": "VULMON",
        "id": "CVE-2022-25752"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-001597"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-25752"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202204-3140"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-28485"
      },
      {
        "db": "VULMON",
        "id": "CVE-2022-25752"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-001597"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-25752"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202204-3140"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2022-04-13T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2022-28485"
      },
      {
        "date": "2022-04-12T00:00:00",
        "db": "VULMON",
        "id": "CVE-2022-25752"
      },
      {
        "date": "2022-04-26T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2022-001597"
      },
      {
        "date": "2022-04-12T09:15:14.650000",
        "db": "NVD",
        "id": "CVE-2022-25752"
      },
      {
        "date": "2022-04-12T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202204-3140"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2022-04-13T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2022-28485"
      },
      {
        "date": "2022-04-19T00:00:00",
        "db": "VULMON",
        "id": "CVE-2022-25752"
      },
      {
        "date": "2022-04-26T09:02:00",
        "db": "JVNDB",
        "id": "JVNDB-2022-001597"
      },
      {
        "date": "2022-04-19T18:07:50.140000",
        "db": "NVD",
        "id": "CVE-2022-25752"
      },
      {
        "date": "2022-04-20T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202204-3140"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202204-3140"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "plural \u00a0SCALANCE\u00a0 Insufficient random value usage vulnerability in product",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-001597"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "security feature problem",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202204-3140"
      }
    ],
    "trust": 0.6
  }
}

var-202204-0499
Vulnerability from variot

A vulnerability has been identified in SCALANCE X302-7 EEC (230V), SCALANCE X302-7 EEC (230V, coated), SCALANCE X302-7 EEC (24V), SCALANCE X302-7 EEC (24V, coated), SCALANCE X302-7 EEC (2x 230V), SCALANCE X302-7 EEC (2x 230V, coated), SCALANCE X302-7 EEC (2x 24V), SCALANCE X302-7 EEC (2x 24V, coated), SCALANCE X304-2FE, SCALANCE X306-1LD FE, SCALANCE X307-2 EEC (230V), SCALANCE X307-2 EEC (230V, coated), SCALANCE X307-2 EEC (24V), SCALANCE X307-2 EEC (24V, coated), SCALANCE X307-2 EEC (2x 230V), SCALANCE X307-2 EEC (2x 230V, coated), SCALANCE X307-2 EEC (2x 24V), SCALANCE X307-2 EEC (2x 24V, coated), SCALANCE X307-3, SCALANCE X307-3, SCALANCE X307-3LD, SCALANCE X307-3LD, SCALANCE X308-2, SCALANCE X308-2, SCALANCE X308-2LD, SCALANCE X308-2LD, SCALANCE X308-2LH, SCALANCE X308-2LH, SCALANCE X308-2LH+, SCALANCE X308-2LH+, SCALANCE X308-2M, SCALANCE X308-2M, SCALANCE X308-2M PoE, SCALANCE X308-2M PoE, SCALANCE X308-2M TS, SCALANCE X308-2M TS, SCALANCE X310, SCALANCE X310, SCALANCE X310FE, SCALANCE X310FE, SCALANCE X320-1 FE, SCALANCE X320-1-2LD FE, SCALANCE X408-2, SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M TS (24V), SCALANCE XR324-12M TS (24V), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M PoE (230V, ports on front), SCALANCE XR324-4M PoE (230V, ports on rear), SCALANCE XR324-4M PoE (24V, ports on front), SCALANCE XR324-4M PoE (24V, ports on rear), SCALANCE XR324-4M PoE TS (24V, ports on front), SIPLUS NET SCALANCE X308-2. The integrated web server could allow Cross-Site Scripting (XSS) attacks if unsuspecting users are tricked into accessing a malicious link. This can be used by an attacker to trigger a malicious request on the affected device. plural SCALANCE The product contains a cross-site scripting vulnerability.Information may be obtained and information may be tampered with. SCALANCE X switches are used to connect industrial components such as programmable logic controllers (PLC) or human machine interfaces (HMI). SIPLUS extreme is designed for reliable operation under extreme conditions

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202204-0499",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "scalance xr324-4m eec",
        "scope": "lt",
        "trust": 1.6,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance xr324-4m poe",
        "scope": "lt",
        "trust": 1.6,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance xr324-4m poe ts",
        "scope": "lt",
        "trust": 1.6,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance xr324-12m",
        "scope": "lt",
        "trust": 1.6,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance xr324-12m ts",
        "scope": "lt",
        "trust": 1.6,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance x308-2m",
        "scope": "lt",
        "trust": 1.6,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance x307-3ld",
        "scope": "lt",
        "trust": 1.6,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance x304-2fe",
        "scope": "lt",
        "trust": 1.6,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance x310fe",
        "scope": "lt",
        "trust": 1.6,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance x308-2m ts",
        "scope": "lt",
        "trust": 1.6,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance x308-2ld",
        "scope": "lt",
        "trust": 1.6,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance x308-2lh",
        "scope": "lt",
        "trust": 1.6,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance x320-1fe",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance x307-3",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance x302-7eec",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance x320-1-2ldfe",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "siplus net scalance x308-2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance x408-2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance x308-2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance x306-1ldfe",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance x308-2m poe",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance x308-2lh\\+",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance x310",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance x307-2eec",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance x304-2fe",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance x307-3ld",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance x307-3",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance x308-2",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance x307-2eec",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance x308-2ld",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance x308-2lh+",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance x308-2lh",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance x306-1ldfe",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance x302-7eec",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "scalance fe",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "x320-1\u003c4.1.4"
      },
      {
        "model": "scalance x320-1-2ld fe",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "x408-2\u003c4.1.4"
      },
      {
        "model": "siplus net scalance",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "x308-2\u003c4.1.4"
      },
      {
        "model": "scalance",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "x307-3\u003c4.1.4"
      },
      {
        "model": "scalance eec",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "x307-2\u003c4.1.4"
      },
      {
        "model": "scalance x306-1ld fe",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance eec",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "x302-7\u003c4.1.4"
      },
      {
        "model": "scalance",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "x310\u003c4.1.4"
      },
      {
        "model": "scalance x308-2m poe",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.1.4"
      },
      {
        "model": "scalance",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "x308-2\u003c4.1.4"
      },
      {
        "model": "scalance x308-2lh+",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "4.1.4"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-28481"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-001593"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-25756"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x302-7eec_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x302-7eec:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x304-2fe_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x304-2fe:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x306-1ldfe_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x306-1ldfe:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x307-2eec_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x307-2eec:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x307-3_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x307-3:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x307-3ld_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x307-3ld:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x308-2_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x308-2:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x308-2ld_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x308-2ld:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x308-2lh_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x308-2lh:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x308-2lh\\+_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x308-2lh\\+:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x308-2m_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x308-2m:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x308-2m_poe_firmware:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x308-2m_poe:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x308-2m_ts_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x308-2m_ts:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x310_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x310:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x310fe_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x310fe:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x320-1fe_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x320-1fe:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x320-1-2ldfe_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x320-1-2ldfe:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_x408-2_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_x408-2:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xr324-4m_eec_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xr324-4m_eec:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xr324-4m_poe_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xr324-4m_poe:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xr324-4m_poe_ts_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xr324-4m_poe_ts:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xr324-12m_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xr324-12m:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:scalance_xr324-12m_ts_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:scalance_xr324-12m_ts:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:siemens:siplus_net_scalance_x308-2_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "4.1.4",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:siemens:siplus_net_scalance_x308-2:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2022-25756"
      }
    ]
  },
  "credits": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/credits#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Michael Messner and Abian Blome of Siemens Energy coordinated the disclosure of CVE-2022-25751 and CVE-2022-25756 to CISA.",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202204-3137"
      }
    ],
    "trust": 0.6
  },
  "cve": "CVE-2022-25756",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "acInsufInfo": false,
            "accessComplexity": "MEDIUM",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "NVD",
            "availabilityImpact": "NONE",
            "baseScore": 4.3,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 8.6,
            "impactScore": 2.9,
            "integrityImpact": "PARTIAL",
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "severity": "MEDIUM",
            "trust": 1.0,
            "userInteractionRequired": true,
            "vectorString": "AV:N/AC:M/Au:N/C:N/I:P/A:N",
            "version": "2.0"
          },
          {
            "acInsufInfo": null,
            "accessComplexity": "Medium",
            "accessVector": "Network",
            "authentication": "None",
            "author": "NVD",
            "availabilityImpact": "None",
            "baseScore": 4.3,
            "confidentialityImpact": "None",
            "exploitabilityScore": null,
            "id": "CVE-2022-25756",
            "impactScore": null,
            "integrityImpact": "Partial",
            "obtainAllPrivilege": null,
            "obtainOtherPrivilege": null,
            "obtainUserPrivilege": null,
            "severity": "Medium",
            "trust": 0.9,
            "userInteractionRequired": null,
            "vectorString": "AV:N/AC:M/Au:N/C:N/I:P/A:N",
            "version": "2.0"
          },
          {
            "accessComplexity": "HIGH",
            "accessVector": "ADJACENT_NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 6.8,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 3.2,
            "id": "CNVD-2022-28481",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "MEDIUM",
            "trust": 0.6,
            "vectorString": "AV:A/AC:H/Au:N/C:C/I:C/A:C",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "NVD",
            "availabilityImpact": "NONE",
            "baseScore": 6.1,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "exploitabilityScore": 2.8,
            "impactScore": 2.7,
            "integrityImpact": "LOW",
            "privilegesRequired": "NONE",
            "scope": "CHANGED",
            "trust": 1.0,
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "None",
            "baseScore": 6.1,
            "baseSeverity": "Medium",
            "confidentialityImpact": "Low",
            "exploitabilityScore": null,
            "id": "CVE-2022-25756",
            "impactScore": null,
            "integrityImpact": "Low",
            "privilegesRequired": "None",
            "scope": "Changed",
            "trust": 0.8,
            "userInteraction": "Required",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "NVD",
            "id": "CVE-2022-25756",
            "trust": 1.8,
            "value": "MEDIUM"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2022-28481",
            "trust": 0.6,
            "value": "MEDIUM"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202204-3137",
            "trust": 0.6,
            "value": "MEDIUM"
          },
          {
            "author": "VULMON",
            "id": "CVE-2022-25756",
            "trust": 0.1,
            "value": "MEDIUM"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-28481"
      },
      {
        "db": "VULMON",
        "id": "CVE-2022-25756"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-001593"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-25756"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202204-3137"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "A vulnerability has been identified in SCALANCE X302-7 EEC (230V), SCALANCE X302-7 EEC (230V, coated), SCALANCE X302-7 EEC (24V), SCALANCE X302-7 EEC (24V, coated), SCALANCE X302-7 EEC (2x 230V), SCALANCE X302-7 EEC (2x 230V, coated), SCALANCE X302-7 EEC (2x 24V), SCALANCE X302-7 EEC (2x 24V, coated), SCALANCE X304-2FE, SCALANCE X306-1LD FE, SCALANCE X307-2 EEC (230V), SCALANCE X307-2 EEC (230V, coated), SCALANCE X307-2 EEC (24V), SCALANCE X307-2 EEC (24V, coated), SCALANCE X307-2 EEC (2x 230V), SCALANCE X307-2 EEC (2x 230V, coated), SCALANCE X307-2 EEC (2x 24V), SCALANCE X307-2 EEC (2x 24V, coated), SCALANCE X307-3, SCALANCE X307-3, SCALANCE X307-3LD, SCALANCE X307-3LD, SCALANCE X308-2, SCALANCE X308-2, SCALANCE X308-2LD, SCALANCE X308-2LD, SCALANCE X308-2LH, SCALANCE X308-2LH, SCALANCE X308-2LH+, SCALANCE X308-2LH+, SCALANCE X308-2M, SCALANCE X308-2M, SCALANCE X308-2M PoE, SCALANCE X308-2M PoE, SCALANCE X308-2M TS, SCALANCE X308-2M TS, SCALANCE X310, SCALANCE X310, SCALANCE X310FE, SCALANCE X310FE, SCALANCE X320-1 FE, SCALANCE X320-1-2LD FE, SCALANCE X408-2, SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M TS (24V), SCALANCE XR324-12M TS (24V), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M PoE (230V, ports on front), SCALANCE XR324-4M PoE (230V, ports on rear), SCALANCE XR324-4M PoE (24V, ports on front), SCALANCE XR324-4M PoE (24V, ports on rear), SCALANCE XR324-4M PoE TS (24V, ports on front), SIPLUS NET SCALANCE X308-2. The integrated web server could allow Cross-Site Scripting (XSS) attacks if unsuspecting users are tricked into accessing a malicious link. This can be used by an attacker to trigger a malicious request on the affected device. plural  SCALANCE The product contains a cross-site scripting vulnerability.Information may be obtained and information may be tampered with. SCALANCE X switches are used to connect industrial components such as programmable logic controllers (PLC) or human machine interfaces (HMI). SIPLUS extreme is designed for reliable operation under extreme conditions",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2022-25756"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-001593"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2022-28481"
      },
      {
        "db": "VULMON",
        "id": "CVE-2022-25756"
      }
    ],
    "trust": 2.25
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2022-25756",
        "trust": 3.9
      },
      {
        "db": "SIEMENS",
        "id": "SSA-836527",
        "trust": 2.3
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-22-104-09",
        "trust": 1.5
      },
      {
        "db": "JVN",
        "id": "JVNVU91165555",
        "trust": 0.8
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-001593",
        "trust": 0.8
      },
      {
        "db": "CNVD",
        "id": "CNVD-2022-28481",
        "trust": 0.6
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202204-3137",
        "trust": 0.6
      },
      {
        "db": "VULMON",
        "id": "CVE-2022-25756",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-28481"
      },
      {
        "db": "VULMON",
        "id": "CVE-2022-25756"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-001593"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-25756"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202204-3137"
      }
    ]
  },
  "id": "VAR-202204-0499",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-28481"
      }
    ],
    "trust": 1.2919426426666667
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "ICS"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-28481"
      }
    ]
  },
  "last_update_date": "2023-12-18T11:56:14.622000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "SSA-836527",
        "trust": 0.8,
        "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-836527.pdf"
      },
      {
        "title": "Patch for Siemens SCALANCE X-300 Switch Family Devices Cross-Site Scripting Vulnerability",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchinfo/show/329331"
      },
      {
        "title": "Multiple  Siemens Fixes for product cross-site scripting vulnerabilities",
        "trust": 0.6,
        "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=190127"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-28481"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-001593"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202204-3137"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-79",
        "trust": 1.0
      },
      {
        "problemtype": "Cross-site scripting (CWE-79) [NVD Evaluation ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-001593"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-25756"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.3,
        "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-836527.pdf"
      },
      {
        "trust": 0.9,
        "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-104-09"
      },
      {
        "trust": 0.8,
        "url": "https://jvn.jp/vu/jvnvu91165555/"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2022-25756"
      },
      {
        "trust": 0.6,
        "url": "https://cxsecurity.com/cveshow/cve-2022-25756/"
      },
      {
        "trust": 0.6,
        "url": "https://us-cert.cisa.gov/ics/advisories/icsa-22-104-09"
      },
      {
        "trust": 0.1,
        "url": "https://cwe.mitre.org/data/definitions/79.html"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-28481"
      },
      {
        "db": "VULMON",
        "id": "CVE-2022-25756"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-001593"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-25756"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202204-3137"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-28481"
      },
      {
        "db": "VULMON",
        "id": "CVE-2022-25756"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-001593"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-25756"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202204-3137"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2022-04-13T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2022-28481"
      },
      {
        "date": "2022-04-12T00:00:00",
        "db": "VULMON",
        "id": "CVE-2022-25756"
      },
      {
        "date": "2022-04-26T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2022-001593"
      },
      {
        "date": "2022-04-12T09:15:14.837000",
        "db": "NVD",
        "id": "CVE-2022-25756"
      },
      {
        "date": "2022-04-12T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202204-3137"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2022-04-13T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2022-28481"
      },
      {
        "date": "2022-04-19T00:00:00",
        "db": "VULMON",
        "id": "CVE-2022-25756"
      },
      {
        "date": "2022-04-26T08:55:00",
        "db": "JVNDB",
        "id": "JVNDB-2022-001593"
      },
      {
        "date": "2022-04-19T18:10:11.827000",
        "db": "NVD",
        "id": "CVE-2022-25756"
      },
      {
        "date": "2022-04-20T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202204-3137"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202204-3137"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "plural \u00a0SCALANCE\u00a0 Cross-site scripting vulnerabilities in products",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-001593"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "XSS",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202204-3137"
      }
    ],
    "trust": 0.6
  }
}

cve-2022-26335
Vulnerability from cvelistv5
Published
2022-04-12 09:07
Modified
2024-08-03 05:03
Severity
Summary
A vulnerability has been identified in SCALANCE X302-7 EEC (230V), SCALANCE X302-7 EEC (230V, coated), SCALANCE X302-7 EEC (24V), SCALANCE X302-7 EEC (24V, coated), SCALANCE X302-7 EEC (2x 230V), SCALANCE X302-7 EEC (2x 230V, coated), SCALANCE X302-7 EEC (2x 24V), SCALANCE X302-7 EEC (2x 24V, coated), SCALANCE X304-2FE, SCALANCE X306-1LD FE, SCALANCE X307-2 EEC (230V), SCALANCE X307-2 EEC (230V, coated), SCALANCE X307-2 EEC (24V), SCALANCE X307-2 EEC (24V, coated), SCALANCE X307-2 EEC (2x 230V), SCALANCE X307-2 EEC (2x 230V, coated), SCALANCE X307-2 EEC (2x 24V), SCALANCE X307-2 EEC (2x 24V, coated), SCALANCE X307-3, SCALANCE X307-3, SCALANCE X307-3LD, SCALANCE X307-3LD, SCALANCE X308-2, SCALANCE X308-2, SCALANCE X308-2LD, SCALANCE X308-2LD, SCALANCE X308-2LH, SCALANCE X308-2LH, SCALANCE X308-2LH+, SCALANCE X308-2LH+, SCALANCE X308-2M, SCALANCE X308-2M, SCALANCE X308-2M PoE, SCALANCE X308-2M PoE, SCALANCE X308-2M TS, SCALANCE X308-2M TS, SCALANCE X310, SCALANCE X310, SCALANCE X310FE, SCALANCE X310FE, SCALANCE X320-1 FE, SCALANCE X320-1-2LD FE, SCALANCE X408-2, SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M TS (24V), SCALANCE XR324-12M TS (24V), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M PoE (230V, ports on front), SCALANCE XR324-4M PoE (230V, ports on rear), SCALANCE XR324-4M PoE (24V, ports on front), SCALANCE XR324-4M PoE (24V, ports on rear), SCALANCE XR324-4M PoE TS (24V, ports on front), SIPLUS NET SCALANCE X308-2. Affected devices do not properly validate the URI of incoming HTTP GET requests. This could allow an unauthenticated remote attacker to crash affected devices.
Impacted products
VendorProduct
SiemensSCALANCE X302-7 EEC (230V)
SiemensSCALANCE X302-7 EEC (230V, coated)
SiemensSCALANCE X302-7 EEC (24V)
SiemensSCALANCE X302-7 EEC (24V, coated)
SiemensSCALANCE X302-7 EEC (2x 230V)
SiemensSCALANCE X302-7 EEC (2x 230V, coated)
SiemensSCALANCE X302-7 EEC (2x 24V)
SiemensSCALANCE X302-7 EEC (2x 24V, coated)
SiemensSCALANCE X304-2FE
SiemensSCALANCE X306-1LD FE
SiemensSCALANCE X307-2 EEC (230V)
SiemensSCALANCE X307-2 EEC (230V, coated)
SiemensSCALANCE X307-2 EEC (24V)
SiemensSCALANCE X307-2 EEC (24V, coated)
SiemensSCALANCE X307-2 EEC (2x 230V)
SiemensSCALANCE X307-2 EEC (2x 230V, coated)
SiemensSCALANCE X307-2 EEC (2x 24V)
SiemensSCALANCE X307-2 EEC (2x 24V, coated)
SiemensSCALANCE X307-3
SiemensSCALANCE X307-3
SiemensSCALANCE X307-3LD
SiemensSCALANCE X307-3LD
SiemensSCALANCE X308-2
SiemensSCALANCE X308-2
SiemensSCALANCE X308-2LD
SiemensSCALANCE X308-2LD
SiemensSCALANCE X308-2LH
SiemensSCALANCE X308-2LH
SiemensSCALANCE X308-2LH+
SiemensSCALANCE X308-2LH+
SiemensSCALANCE X308-2M
SiemensSCALANCE X308-2M
SiemensSCALANCE X308-2M PoE
SiemensSCALANCE X308-2M PoE
SiemensSCALANCE X308-2M TS
SiemensSCALANCE X308-2M TS
SiemensSCALANCE X310
SiemensSCALANCE X310
SiemensSCALANCE X310FE
SiemensSCALANCE X310FE
SiemensSCALANCE X320-1 FE
SiemensSCALANCE X320-1-2LD FE
SiemensSCALANCE X408-2
SiemensSCALANCE XR324-12M (230V, ports on front)
SiemensSCALANCE XR324-12M (230V, ports on front)
SiemensSCALANCE XR324-12M (230V, ports on rear)
SiemensSCALANCE XR324-12M (230V, ports on rear)
SiemensSCALANCE XR324-12M (24V, ports on front)
SiemensSCALANCE XR324-12M (24V, ports on front)
SiemensSCALANCE XR324-12M (24V, ports on rear)
SiemensSCALANCE XR324-12M (24V, ports on rear)
SiemensSCALANCE XR324-12M TS (24V)
SiemensSCALANCE XR324-12M TS (24V)
SiemensSCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)
SiemensSCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)
SiemensSCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)
SiemensSCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)
SiemensSCALANCE XR324-4M EEC (24V, ports on front)
SiemensSCALANCE XR324-4M EEC (24V, ports on front)
SiemensSCALANCE XR324-4M EEC (24V, ports on rear)
SiemensSCALANCE XR324-4M EEC (24V, ports on rear)
SiemensSCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)
SiemensSCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)
SiemensSCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)
SiemensSCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)
SiemensSCALANCE XR324-4M EEC (2x 24V, ports on front)
SiemensSCALANCE XR324-4M EEC (2x 24V, ports on front)
SiemensSCALANCE XR324-4M EEC (2x 24V, ports on rear)
SiemensSCALANCE XR324-4M EEC (2x 24V, ports on rear)
SiemensSCALANCE XR324-4M PoE (230V, ports on front)
SiemensSCALANCE XR324-4M PoE (230V, ports on rear)
SiemensSCALANCE XR324-4M PoE (24V, ports on front)
SiemensSCALANCE XR324-4M PoE (24V, ports on rear)
SiemensSCALANCE XR324-4M PoE TS (24V, ports on front)
SiemensSIPLUS NET SCALANCE X308-2
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T05:03:31.738Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-836527.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "SCALANCE X302-7 EEC (230V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X302-7 EEC (230V, coated)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X302-7 EEC (24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X302-7 EEC (24V, coated)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X302-7 EEC (2x 230V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X302-7 EEC (2x 230V, coated)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X302-7 EEC (2x 24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X302-7 EEC (2x 24V, coated)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X304-2FE",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X306-1LD FE",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X307-2 EEC (230V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X307-2 EEC (230V, coated)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X307-2 EEC (24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X307-2 EEC (24V, coated)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X307-2 EEC (2x 230V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X307-2 EEC (2x 230V, coated)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X307-2 EEC (2x 24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X307-2 EEC (2x 24V, coated)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X307-3",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X307-3",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X307-3LD",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X307-3LD",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2LD",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2LD",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2LH",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2LH",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2LH+",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2LH+",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2M",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2M",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2M PoE",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2M PoE",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2M TS",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2M TS",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X310",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X310",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X310FE",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X310FE",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X320-1 FE",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X320-1-2LD FE",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X408-2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-12M (230V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-12M (230V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-12M (230V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-12M (230V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-12M (24V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-12M (24V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-12M (24V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-12M (24V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-12M TS (24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-12M TS (24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (24V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (24V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (24V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (24V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (2x 24V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (2x 24V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (2x 24V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (2x 24V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M PoE (230V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M PoE (230V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M PoE (24V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M PoE (24V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M PoE TS (24V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SIPLUS NET SCALANCE X308-2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in SCALANCE X302-7 EEC (230V), SCALANCE X302-7 EEC (230V, coated), SCALANCE X302-7 EEC (24V), SCALANCE X302-7 EEC (24V, coated), SCALANCE X302-7 EEC (2x 230V), SCALANCE X302-7 EEC (2x 230V, coated), SCALANCE X302-7 EEC (2x 24V), SCALANCE X302-7 EEC (2x 24V, coated), SCALANCE X304-2FE, SCALANCE X306-1LD FE, SCALANCE X307-2 EEC (230V), SCALANCE X307-2 EEC (230V, coated), SCALANCE X307-2 EEC (24V), SCALANCE X307-2 EEC (24V, coated), SCALANCE X307-2 EEC (2x 230V), SCALANCE X307-2 EEC (2x 230V, coated), SCALANCE X307-2 EEC (2x 24V), SCALANCE X307-2 EEC (2x 24V, coated), SCALANCE X307-3, SCALANCE X307-3, SCALANCE X307-3LD, SCALANCE X307-3LD, SCALANCE X308-2, SCALANCE X308-2, SCALANCE X308-2LD, SCALANCE X308-2LD, SCALANCE X308-2LH, SCALANCE X308-2LH, SCALANCE X308-2LH+, SCALANCE X308-2LH+, SCALANCE X308-2M, SCALANCE X308-2M, SCALANCE X308-2M PoE, SCALANCE X308-2M PoE, SCALANCE X308-2M TS, SCALANCE X308-2M TS, SCALANCE X310, SCALANCE X310, SCALANCE X310FE, SCALANCE X310FE, SCALANCE X320-1 FE, SCALANCE X320-1-2LD FE, SCALANCE X408-2, SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M TS (24V), SCALANCE XR324-12M TS (24V), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M PoE (230V, ports on front), SCALANCE XR324-4M PoE (230V, ports on rear), SCALANCE XR324-4M PoE (24V, ports on front), SCALANCE XR324-4M PoE (24V, ports on rear), SCALANCE XR324-4M PoE TS (24V, ports on front), SIPLUS NET SCALANCE X308-2. Affected devices do not properly validate the URI of incoming HTTP GET requests. This could allow an unauthenticated remote attacker to crash affected devices."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-120",
              "description": "CWE-120: Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-04-12T09:07:55",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-836527.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2022-26335",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "SCALANCE X302-7 EEC (230V)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X302-7 EEC (230V, coated)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X302-7 EEC (24V)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X302-7 EEC (24V, coated)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X302-7 EEC (2x 230V)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X302-7 EEC (2x 230V, coated)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X302-7 EEC (2x 24V)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X302-7 EEC (2x 24V, coated)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X304-2FE",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X306-1LD FE",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X307-2 EEC (230V)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X307-2 EEC (230V, coated)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X307-2 EEC (24V)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X307-2 EEC (24V, coated)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X307-2 EEC (2x 230V)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X307-2 EEC (2x 230V, coated)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X307-2 EEC (2x 24V)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X307-2 EEC (2x 24V, coated)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X307-3",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X307-3",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X307-3LD",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X307-3LD",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2LD",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2LD",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2LH",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2LH",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2LH+",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2LH+",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2M",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2M",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2M PoE",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2M PoE",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2M TS",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2M TS",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X310",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X310",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X310FE",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X310FE",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X320-1 FE",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X320-1-2LD FE",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X408-2",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-12M (230V, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-12M (230V, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-12M (230V, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-12M (230V, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-12M (24V, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-12M (24V, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-12M (24V, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-12M (24V, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-12M TS (24V)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-12M TS (24V)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (24V, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (24V, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (24V, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (24V, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (2x 24V, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (2x 24V, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (2x 24V, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (2x 24V, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M PoE (230V, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M PoE (230V, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M PoE (24V, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M PoE (24V, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M PoE TS (24V, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIPLUS NET SCALANCE X308-2",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in SCALANCE X302-7 EEC (230V), SCALANCE X302-7 EEC (230V, coated), SCALANCE X302-7 EEC (24V), SCALANCE X302-7 EEC (24V, coated), SCALANCE X302-7 EEC (2x 230V), SCALANCE X302-7 EEC (2x 230V, coated), SCALANCE X302-7 EEC (2x 24V), SCALANCE X302-7 EEC (2x 24V, coated), SCALANCE X304-2FE, SCALANCE X306-1LD FE, SCALANCE X307-2 EEC (230V), SCALANCE X307-2 EEC (230V, coated), SCALANCE X307-2 EEC (24V), SCALANCE X307-2 EEC (24V, coated), SCALANCE X307-2 EEC (2x 230V), SCALANCE X307-2 EEC (2x 230V, coated), SCALANCE X307-2 EEC (2x 24V), SCALANCE X307-2 EEC (2x 24V, coated), SCALANCE X307-3, SCALANCE X307-3, SCALANCE X307-3LD, SCALANCE X307-3LD, SCALANCE X308-2, SCALANCE X308-2, SCALANCE X308-2LD, SCALANCE X308-2LD, SCALANCE X308-2LH, SCALANCE X308-2LH, SCALANCE X308-2LH+, SCALANCE X308-2LH+, SCALANCE X308-2M, SCALANCE X308-2M, SCALANCE X308-2M PoE, SCALANCE X308-2M PoE, SCALANCE X308-2M TS, SCALANCE X308-2M TS, SCALANCE X310, SCALANCE X310, SCALANCE X310FE, SCALANCE X310FE, SCALANCE X320-1 FE, SCALANCE X320-1-2LD FE, SCALANCE X408-2, SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M TS (24V), SCALANCE XR324-12M TS (24V), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M PoE (230V, ports on front), SCALANCE XR324-4M PoE (230V, ports on rear), SCALANCE XR324-4M PoE (24V, ports on front), SCALANCE XR324-4M PoE (24V, ports on rear), SCALANCE XR324-4M PoE TS (24V, ports on front), SIPLUS NET SCALANCE X308-2. Affected devices do not properly validate the URI of incoming HTTP GET requests. This could allow an unauthenticated remote attacker to crash affected devices."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-120: Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-836527.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-836527.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2022-26335",
    "datePublished": "2022-04-12T09:07:55",
    "dateReserved": "2022-03-01T00:00:00",
    "dateUpdated": "2024-08-03T05:03:31.738Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2019-13946
Vulnerability from cvelistv5
Published
2020-02-11 15:36
Modified
2024-08-05 00:05
Summary
Profinet-IO (PNIO) stack versions prior V06.00 do not properly limit internal resource allocation when multiple legitimate diagnostic package requests are sent to the DCE-RPC interface. This could lead to a denial of service condition due to lack of memory for devices that include a vulnerable version of the stack. The security vulnerability could be exploited by an attacker with network access to an affected device. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise the availability of the device.
Impacted products
VendorProduct
SiemensDevelopment/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller
SiemensDevelopment/Evaluation Kits for PROFINET IO: EK-ERTEC 200
SiemensDevelopment/Evaluation Kits for PROFINET IO: EK-ERTEC 200P
SiemensPROFINET Driver for Controller
SiemensRUGGEDCOM RM1224 family
SiemensSCALANCE M804PB
SiemensSCALANCE M812-1 ADSL-Router
SiemensSCALANCE M812-1 ADSL-Router
SiemensSCALANCE M816-1 ADSL-Router
SiemensSCALANCE M816-1 ADSL-Router
SiemensSCALANCE M826-2 SHDSL-Router
SiemensSCALANCE M874-2
SiemensSCALANCE M874-3
SiemensSCALANCE M876-3
SiemensSCALANCE M876-3 (ROK)
SiemensSCALANCE M876-4 (EU)
SiemensSCALANCE M876-4 (NAM)
SiemensSCALANCE S615 LAN-Router
SiemensSCALANCE W-700 IEEE 802.11n family
SiemensSCALANCE X200-4P IRT
SiemensSCALANCE X201-3P IRT
SiemensSCALANCE X201-3P IRT PRO
SiemensSCALANCE X202-2IRT
SiemensSCALANCE X202-2P IRT
SiemensSCALANCE X202-2P IRT PRO
SiemensSCALANCE X204-2
SiemensSCALANCE X204-2FM
SiemensSCALANCE X204-2LD
SiemensSCALANCE X204-2LD TS
SiemensSCALANCE X204-2TS
SiemensSCALANCE X204IRT
SiemensSCALANCE X204IRT PRO
SiemensSCALANCE X206-1
SiemensSCALANCE X206-1LD
SiemensSCALANCE X208
SiemensSCALANCE X208PRO
SiemensSCALANCE X212-2
SiemensSCALANCE X212-2LD
SiemensSCALANCE X216
SiemensSCALANCE X224
SiemensSCALANCE X302-7 EEC (230V, coated)
SiemensSCALANCE X302-7 EEC (230V)
SiemensSCALANCE X302-7 EEC (24V, coated)
SiemensSCALANCE X302-7 EEC (24V)
SiemensSCALANCE X302-7 EEC (2x 230V, coated)
SiemensSCALANCE X302-7 EEC (2x 230V)
SiemensSCALANCE X302-7 EEC (2x 24V, coated)
SiemensSCALANCE X302-7 EEC (2x 24V)
SiemensSCALANCE X304-2FE
SiemensSCALANCE X306-1LD FE
SiemensSCALANCE X307-2 EEC (230V, coated)
SiemensSCALANCE X307-2 EEC (230V)
SiemensSCALANCE X307-2 EEC (24V, coated)
SiemensSCALANCE X307-2 EEC (24V)
SiemensSCALANCE X307-2 EEC (2x 230V, coated)
SiemensSCALANCE X307-2 EEC (2x 230V)
SiemensSCALANCE X307-2 EEC (2x 24V, coated)
SiemensSCALANCE X307-2 EEC (2x 24V)
SiemensSCALANCE X307-3
SiemensSCALANCE X307-3
SiemensSCALANCE X307-3LD
SiemensSCALANCE X307-3LD
SiemensSCALANCE X308-2
SiemensSCALANCE X308-2
SiemensSCALANCE X308-2LD
SiemensSCALANCE X308-2LD
SiemensSCALANCE X308-2LH
SiemensSCALANCE X308-2LH
SiemensSCALANCE X308-2LH+
SiemensSCALANCE X308-2LH+
SiemensSCALANCE X308-2M
SiemensSCALANCE X308-2M
SiemensSCALANCE X308-2M PoE
SiemensSCALANCE X308-2M PoE
SiemensSCALANCE X308-2M TS
SiemensSCALANCE X308-2M TS
SiemensSCALANCE X310
SiemensSCALANCE X310
SiemensSCALANCE X310FE
SiemensSCALANCE X310FE
SiemensSCALANCE X320-1 FE
SiemensSCALANCE X320-1-2LD FE
SiemensSCALANCE X408-2
SiemensSCALANCE XB-200 family
SiemensSCALANCE XC-200
SiemensSCALANCE XF-200BA
SiemensSCALANCE XF201-3P IRT
SiemensSCALANCE XF202-2P IRT
SiemensSCALANCE XF204
SiemensSCALANCE XF204-2
SiemensSCALANCE XF204-2BA IRT
SiemensSCALANCE XF204IRT
SiemensSCALANCE XF206-1
SiemensSCALANCE XF208
SiemensSCALANCE XM-400 family
SiemensSCALANCE XP-200
SiemensSCALANCE XR-300WG family
SiemensSCALANCE XR-500 family
SiemensSCALANCE XR324-12M (230V, ports on front)
SiemensSCALANCE XR324-12M (230V, ports on front)
SiemensSCALANCE XR324-12M (230V, ports on rear)
SiemensSCALANCE XR324-12M (230V, ports on rear)
SiemensSCALANCE XR324-12M (24V, ports on front)
SiemensSCALANCE XR324-12M (24V, ports on front)
SiemensSCALANCE XR324-12M (24V, ports on rear)
SiemensSCALANCE XR324-12M (24V, ports on rear)
SiemensSCALANCE XR324-12M TS (24V)
SiemensSCALANCE XR324-12M TS (24V)
SiemensSCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)
SiemensSCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)
SiemensSCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)
SiemensSCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)
SiemensSCALANCE XR324-4M EEC (24V, ports on front)
SiemensSCALANCE XR324-4M EEC (24V, ports on front)
SiemensSCALANCE XR324-4M EEC (24V, ports on rear)
SiemensSCALANCE XR324-4M EEC (24V, ports on rear)
SiemensSCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)
SiemensSCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)
SiemensSCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)
SiemensSCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)
SiemensSCALANCE XR324-4M EEC (2x 24V, ports on front)
SiemensSCALANCE XR324-4M EEC (2x 24V, ports on front)
SiemensSCALANCE XR324-4M EEC (2x 24V, ports on rear)
SiemensSCALANCE XR324-4M EEC (2x 24V, ports on rear)
SiemensSCALANCE XR324-4M PoE (230V, ports on front)
SiemensSCALANCE XR324-4M PoE (230V, ports on rear)
SiemensSCALANCE XR324-4M PoE (24V, ports on front)
SiemensSCALANCE XR324-4M PoE (24V, ports on rear)
SiemensSCALANCE XR324-4M PoE TS (24V, ports on front)
SiemensSIMATIC CP 1616 and CP 1604
SiemensSIMATIC CP 343-1
SiemensSIMATIC CP 343-1 Advanced
SiemensSIMATIC CP 343-1 ERPC
SiemensSIMATIC CP 343-1 Lean
SiemensSIMATIC CP 443-1
SiemensSIMATIC CP 443-1
SiemensSIMATIC CP 443-1 Advanced
SiemensSIMATIC CP 443-1 OPC UA
SiemensSIMATIC ET 200AL IM 157-1 PN
SiemensSIMATIC ET 200M IM 153-4 PN IO HF (incl. SIPLUS variants)
SiemensSIMATIC ET 200M IM 153-4 PN IO ST (incl. SIPLUS variants)
SiemensSIMATIC ET 200MP IM 155-5 PN HF
SiemensSIMATIC ET 200MP IM 155-5 PN ST
SiemensSIMATIC ET 200pro IM 154-3 PN HF
SiemensSIMATIC ET 200pro IM 154-4 PN HF
SiemensSIMATIC ET 200SP IM 155-6 PN BA
SiemensSIMATIC ET 200SP IM 155-6 PN HF
SiemensSIMATIC ET 200SP IM 155-6 PN ST
SiemensSIMATIC ET 200SP IM 155-6 PN ST BA
SiemensSIMATIC ET200ecoPN, 16DI, DC24V, 8xM12
SiemensSIMATIC ET200ecoPN, 16DO DC24V/1,3A, 8xM12
SiemensSIMATIC ET200ecoPN, 4AO U/I 4xM12
SiemensSIMATIC ET200ecoPN, 8 DIO, DC24V/1,3A, 8xM12
SiemensSIMATIC ET200ecoPN, 8 DO, DC24V/2A, 8xM12
SiemensSIMATIC ET200ecoPN, 8AI RTD/TC 8xM12
SiemensSIMATIC ET200ecoPN, 8AI; 4 U/I; 4 RTD/TC 8xM12
SiemensSIMATIC ET200ecoPN, 8DI, DC24V, 4xM12
SiemensSIMATIC ET200ecoPN, 8DI, DC24V, 8xM12
SiemensSIMATIC ET200ecoPN, 8DO, DC24V/0,5A, 4xM12
SiemensSIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 4xM12
SiemensSIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 8xM12
SiemensSIMATIC ET200ecoPN: IO-Link Master
SiemensSIMATIC ET200S (incl. SIPLUS variants)
SiemensSIMATIC IPC Support, Package for VxWorks
SiemensSIMATIC MV420 SR-B
SiemensSIMATIC MV420 SR-B Body
SiemensSIMATIC MV420 SR-P
SiemensSIMATIC MV420 SR-P Body
SiemensSIMATIC MV440 HR
SiemensSIMATIC MV440 SR
SiemensSIMATIC MV440 UR
SiemensSIMATIC PN/PN Coupler (incl. SIPLUS NET variants)
SiemensSIMATIC RF180C
SiemensSIMATIC RF182C
SiemensSIMATIC RF600R family
SiemensSIMOTION C
SiemensSIMOTION D
SiemensSIMOTION P
SiemensSINAMICS DCP
SiemensSIPLUS ET 200MP IM 155-5 PN HF
SiemensSIPLUS ET 200MP IM 155-5 PN HF
SiemensSIPLUS ET 200MP IM 155-5 PN HF T1 RAIL
SiemensSIPLUS ET 200MP IM 155-5 PN ST
SiemensSIPLUS ET 200MP IM 155-5 PN ST TX RAIL
SiemensSIPLUS ET 200SP IM 155-6 PN HF
SiemensSIPLUS ET 200SP IM 155-6 PN HF
SiemensSIPLUS ET 200SP IM 155-6 PN HF T1 RAIL
SiemensSIPLUS ET 200SP IM 155-6 PN ST
SiemensSIPLUS ET 200SP IM 155-6 PN ST BA
SiemensSIPLUS ET 200SP IM 155-6 PN ST BA TX RAIL
SiemensSIPLUS ET 200SP IM 155-6 PN ST TX RAIL
SiemensSIPLUS NET CP 343-1
SiemensSIPLUS NET CP 343-1 Advanced
SiemensSIPLUS NET CP 343-1 Lean
SiemensSIPLUS NET CP 443-1
SiemensSIPLUS NET CP 443-1 Advanced
SiemensSIPLUS NET SCALANCE X308-2
SiemensSOFTNET-IE PNIO
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2019-13946",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-07-09T18:06:01.358486Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-07-09T18:06:09.778Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T00:05:44.023Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-780073.pdf"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/html/ssa-780073.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All Versions \u003c V4.5"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All Versions \u003c V4.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "PROFINET Driver for Controller",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All Versions \u003c V2.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RM1224 family",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M804PB",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M812-1 ADSL-Router",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M812-1 ADSL-Router",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M816-1 ADSL-Router",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M816-1 ADSL-Router",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M826-2 SHDSL-Router",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M874-2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M874-3",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M876-3",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M876-3 (ROK)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M876-4 (EU)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M876-4 (NAM)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE S615 LAN-Router",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W-700 IEEE 802.11n family",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c= V6.0.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X200-4P IRT",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All Versions \u003c V5.3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X201-3P IRT",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All Versions \u003c V5.3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X201-3P IRT PRO",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All Versions \u003c V5.3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X202-2IRT",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All Versions \u003c V5.3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X202-2P IRT",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All Versions \u003c V5.3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X202-2P IRT PRO",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All Versions \u003c V5.3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X204-2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.2.5"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X204-2FM",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.2.5"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X204-2LD",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.2.5"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X204-2LD TS",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.2.5"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X204-2TS",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.2.5"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X204IRT",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All Versions \u003c V5.3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X204IRT PRO",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All Versions \u003c V5.3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X206-1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.2.5"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X206-1LD",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.2.5"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X208",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.2.5"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X208PRO",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.2.5"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X212-2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.2.5"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X212-2LD",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.2.5"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X216",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.2.5"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X224",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.2.5"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X302-7 EEC (230V, coated)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X302-7 EEC (230V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X302-7 EEC (24V, coated)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X302-7 EEC (24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X302-7 EEC (2x 230V, coated)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X302-7 EEC (2x 230V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X302-7 EEC (2x 24V, coated)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X302-7 EEC (2x 24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X304-2FE",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X306-1LD FE",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X307-2 EEC (230V, coated)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X307-2 EEC (230V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X307-2 EEC (24V, coated)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X307-2 EEC (24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X307-2 EEC (2x 230V, coated)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X307-2 EEC (2x 230V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X307-2 EEC (2x 24V, coated)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X307-2 EEC (2x 24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X307-3",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X307-3",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X307-3LD",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X307-3LD",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X308-2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X308-2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X308-2LD",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X308-2LD",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X308-2LH",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X308-2LH",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X308-2LH+",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X308-2LH+",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X308-2M",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X308-2M",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X308-2M PoE",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X308-2M PoE",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X308-2M TS",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X308-2M TS",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X310",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X310",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X310FE",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X310FE",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X320-1 FE",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X320-1-2LD FE",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X408-2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB-200 family",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All Versions \u003c V3.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC-200",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All Versions \u003c V3.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XF-200BA",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All Versions \u003c V3.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XF201-3P IRT",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All Versions \u003c V5.3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XF202-2P IRT",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All Versions \u003c V5.3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XF204",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.2.5"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XF204-2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.2.5"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XF204-2BA IRT",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All Versions \u003c V5.3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XF204IRT",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All Versions \u003c V5.3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XF206-1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.2.5"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XF208",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.2.5"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XM-400 family",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All Versions \u003c V6.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XP-200",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All Versions \u003c V3.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR-300WG family",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All Versions \u003c V3.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR-500 family",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All Versions \u003c V6.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-12M (230V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-12M (230V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-12M (230V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-12M (230V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-12M (24V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-12M (24V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-12M (24V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-12M (24V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-12M TS (24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-12M TS (24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-4M EEC (24V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-4M EEC (24V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-4M EEC (24V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-4M EEC (24V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-4M EEC (2x 24V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-4M EEC (2x 24V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-4M EEC (2x 24V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-4M EEC (2x 24V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-4M PoE (230V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-4M PoE (230V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-4M PoE (24V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-4M PoE (24V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-4M PoE TS (24V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1616 and CP 1604",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All Versions \u003c V2.8"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 343-1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 343-1 Advanced",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 343-1 ERPC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 343-1 Lean",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 443-1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 443-1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 443-1 Advanced",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 443-1 OPC UA",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200AL IM 157-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200M IM 153-4 PN IO HF (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200M IM 153-4 PN IO ST (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200MP IM 155-5 PN HF",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.2.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200MP IM 155-5 PN ST",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200pro IM 154-3 PN HF",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200pro IM 154-4 PN HF",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200SP IM 155-6 PN BA",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200SP IM 155-6 PN HF",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.2.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200SP IM 155-6 PN ST",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200SP IM 155-6 PN ST BA",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET200ecoPN, 16DI, DC24V, 8xM12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET200ecoPN, 16DO DC24V/1,3A, 8xM12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET200ecoPN, 4AO U/I 4xM12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET200ecoPN, 8 DIO, DC24V/1,3A, 8xM12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET200ecoPN, 8 DO, DC24V/2A, 8xM12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET200ecoPN, 8AI RTD/TC 8xM12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET200ecoPN, 8AI; 4 U/I; 4 RTD/TC 8xM12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET200ecoPN, 8DI, DC24V, 4xM12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET200ecoPN, 8DI, DC24V, 8xM12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET200ecoPN, 8DO, DC24V/0,5A, 4xM12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 4xM12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 8xM12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET200ecoPN: IO-Link Master",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET200S (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC IPC Support, Package for VxWorks",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC MV420 SR-B",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.0.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC MV420 SR-B Body",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.0.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC MV420 SR-P",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.0.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC MV420 SR-P Body",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.0.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC MV440 HR",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.0.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC MV440 SR",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.0.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC MV440 UR",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.0.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC PN/PN Coupler (incl. SIPLUS NET variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All Versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC RF180C",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC RF182C",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC RF600R family",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMOTION C",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.5"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMOTION D",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.5"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMOTION P",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.5"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS DCP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All Versions \u003c V1.3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200MP IM 155-5 PN HF",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.2.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200MP IM 155-5 PN HF",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.2.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200MP IM 155-5 PN HF T1 RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.2.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200MP IM 155-5 PN ST",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200MP IM 155-5 PN ST TX RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP IM 155-6 PN HF",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.2.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP IM 155-6 PN HF",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.2.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP IM 155-6 PN HF T1 RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.2.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP IM 155-6 PN ST",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP IM 155-6 PN ST BA",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP IM 155-6 PN ST BA TX RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP IM 155-6 PN ST TX RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS NET CP 343-1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS NET CP 343-1 Advanced",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS NET CP 343-1 Lean",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS NET CP 443-1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS NET CP 443-1 Advanced",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS NET SCALANCE X308-2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SOFTNET-IE PNIO",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Profinet-IO (PNIO) stack versions prior V06.00 do not properly limit\ninternal resource allocation when multiple legitimate diagnostic package\nrequests are sent to the DCE-RPC interface.\nThis could lead to a denial of service condition due to lack of memory\nfor devices that include a vulnerable version of the stack.\n\nThe security vulnerability could be exploited by an attacker with network\naccess to an affected device. Successful exploitation requires no system\nprivileges and no user interaction. An attacker could use the vulnerability\nto compromise the availability of the device."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-400",
              "description": "CWE-400: Uncontrolled Resource Consumption",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-07-09T12:03:58.088Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-780073.pdf"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-780073.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2019-13946",
    "datePublished": "2020-02-11T15:36:10",
    "dateReserved": "2019-07-18T00:00:00",
    "dateUpdated": "2024-08-05T00:05:44.023Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2022-25753
Vulnerability from cvelistv5
Published
2022-04-12 09:07
Modified
2024-08-03 04:49
Severity
Summary
A vulnerability has been identified in SCALANCE X302-7 EEC (230V), SCALANCE X302-7 EEC (230V, coated), SCALANCE X302-7 EEC (24V), SCALANCE X302-7 EEC (24V, coated), SCALANCE X302-7 EEC (2x 230V), SCALANCE X302-7 EEC (2x 230V, coated), SCALANCE X302-7 EEC (2x 24V), SCALANCE X302-7 EEC (2x 24V, coated), SCALANCE X304-2FE, SCALANCE X306-1LD FE, SCALANCE X307-2 EEC (230V), SCALANCE X307-2 EEC (230V, coated), SCALANCE X307-2 EEC (24V), SCALANCE X307-2 EEC (24V, coated), SCALANCE X307-2 EEC (2x 230V), SCALANCE X307-2 EEC (2x 230V, coated), SCALANCE X307-2 EEC (2x 24V), SCALANCE X307-2 EEC (2x 24V, coated), SCALANCE X307-3, SCALANCE X307-3, SCALANCE X307-3LD, SCALANCE X307-3LD, SCALANCE X308-2, SCALANCE X308-2, SCALANCE X308-2LD, SCALANCE X308-2LD, SCALANCE X308-2LH, SCALANCE X308-2LH, SCALANCE X308-2LH+, SCALANCE X308-2LH+, SCALANCE X308-2M, SCALANCE X308-2M, SCALANCE X308-2M PoE, SCALANCE X308-2M PoE, SCALANCE X308-2M TS, SCALANCE X308-2M TS, SCALANCE X310, SCALANCE X310, SCALANCE X310FE, SCALANCE X310FE, SCALANCE X320-1 FE, SCALANCE X320-1-2LD FE, SCALANCE X408-2, SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M TS (24V), SCALANCE XR324-12M TS (24V), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M PoE (230V, ports on front), SCALANCE XR324-4M PoE (230V, ports on rear), SCALANCE XR324-4M PoE (24V, ports on front), SCALANCE XR324-4M PoE (24V, ports on rear), SCALANCE XR324-4M PoE TS (24V, ports on front), SIPLUS NET SCALANCE X308-2. The handling of arguments such as IP addresses in the CLI of affected devices is prone to buffer overflows. This could allow an authenticated remote attacker to execute arbitrary code on the device.
Impacted products
VendorProduct
SiemensSCALANCE X302-7 EEC (230V)
SiemensSCALANCE X302-7 EEC (230V, coated)
SiemensSCALANCE X302-7 EEC (24V)
SiemensSCALANCE X302-7 EEC (24V, coated)
SiemensSCALANCE X302-7 EEC (2x 230V)
SiemensSCALANCE X302-7 EEC (2x 230V, coated)
SiemensSCALANCE X302-7 EEC (2x 24V)
SiemensSCALANCE X302-7 EEC (2x 24V, coated)
SiemensSCALANCE X304-2FE
SiemensSCALANCE X306-1LD FE
SiemensSCALANCE X307-2 EEC (230V)
SiemensSCALANCE X307-2 EEC (230V, coated)
SiemensSCALANCE X307-2 EEC (24V)
SiemensSCALANCE X307-2 EEC (24V, coated)
SiemensSCALANCE X307-2 EEC (2x 230V)
SiemensSCALANCE X307-2 EEC (2x 230V, coated)
SiemensSCALANCE X307-2 EEC (2x 24V)
SiemensSCALANCE X307-2 EEC (2x 24V, coated)
SiemensSCALANCE X307-3
SiemensSCALANCE X307-3
SiemensSCALANCE X307-3LD
SiemensSCALANCE X307-3LD
SiemensSCALANCE X308-2
SiemensSCALANCE X308-2
SiemensSCALANCE X308-2LD
SiemensSCALANCE X308-2LD
SiemensSCALANCE X308-2LH
SiemensSCALANCE X308-2LH
SiemensSCALANCE X308-2LH+
SiemensSCALANCE X308-2LH+
SiemensSCALANCE X308-2M
SiemensSCALANCE X308-2M
SiemensSCALANCE X308-2M PoE
SiemensSCALANCE X308-2M PoE
SiemensSCALANCE X308-2M TS
SiemensSCALANCE X308-2M TS
SiemensSCALANCE X310
SiemensSCALANCE X310
SiemensSCALANCE X310FE
SiemensSCALANCE X310FE
SiemensSCALANCE X320-1 FE
SiemensSCALANCE X320-1-2LD FE
SiemensSCALANCE X408-2
SiemensSCALANCE XR324-12M (230V, ports on front)
SiemensSCALANCE XR324-12M (230V, ports on front)
SiemensSCALANCE XR324-12M (230V, ports on rear)
SiemensSCALANCE XR324-12M (230V, ports on rear)
SiemensSCALANCE XR324-12M (24V, ports on front)
SiemensSCALANCE XR324-12M (24V, ports on front)
SiemensSCALANCE XR324-12M (24V, ports on rear)
SiemensSCALANCE XR324-12M (24V, ports on rear)
SiemensSCALANCE XR324-12M TS (24V)
SiemensSCALANCE XR324-12M TS (24V)
SiemensSCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)
SiemensSCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)
SiemensSCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)
SiemensSCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)
SiemensSCALANCE XR324-4M EEC (24V, ports on front)
SiemensSCALANCE XR324-4M EEC (24V, ports on front)
SiemensSCALANCE XR324-4M EEC (24V, ports on rear)
SiemensSCALANCE XR324-4M EEC (24V, ports on rear)
SiemensSCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)
SiemensSCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)
SiemensSCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)
SiemensSCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)
SiemensSCALANCE XR324-4M EEC (2x 24V, ports on front)
SiemensSCALANCE XR324-4M EEC (2x 24V, ports on front)
SiemensSCALANCE XR324-4M EEC (2x 24V, ports on rear)
SiemensSCALANCE XR324-4M EEC (2x 24V, ports on rear)
SiemensSCALANCE XR324-4M PoE (230V, ports on front)
SiemensSCALANCE XR324-4M PoE (230V, ports on rear)
SiemensSCALANCE XR324-4M PoE (24V, ports on front)
SiemensSCALANCE XR324-4M PoE (24V, ports on rear)
SiemensSCALANCE XR324-4M PoE TS (24V, ports on front)
SiemensSIPLUS NET SCALANCE X308-2
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T04:49:43.901Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-836527.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "SCALANCE X302-7 EEC (230V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X302-7 EEC (230V, coated)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X302-7 EEC (24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X302-7 EEC (24V, coated)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X302-7 EEC (2x 230V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X302-7 EEC (2x 230V, coated)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X302-7 EEC (2x 24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X302-7 EEC (2x 24V, coated)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X304-2FE",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X306-1LD FE",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X307-2 EEC (230V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X307-2 EEC (230V, coated)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X307-2 EEC (24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X307-2 EEC (24V, coated)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X307-2 EEC (2x 230V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X307-2 EEC (2x 230V, coated)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X307-2 EEC (2x 24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X307-2 EEC (2x 24V, coated)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X307-3",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X307-3",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X307-3LD",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X307-3LD",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2LD",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2LD",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2LH",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2LH",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2LH+",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2LH+",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2M",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2M",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2M PoE",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2M PoE",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2M TS",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2M TS",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X310",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X310",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X310FE",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X310FE",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X320-1 FE",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X320-1-2LD FE",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X408-2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-12M (230V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-12M (230V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-12M (230V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-12M (230V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-12M (24V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-12M (24V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-12M (24V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-12M (24V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-12M TS (24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-12M TS (24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (24V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (24V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (24V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (24V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (2x 24V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (2x 24V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (2x 24V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (2x 24V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M PoE (230V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M PoE (230V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M PoE (24V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M PoE (24V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M PoE TS (24V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SIPLUS NET SCALANCE X308-2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in SCALANCE X302-7 EEC (230V), SCALANCE X302-7 EEC (230V, coated), SCALANCE X302-7 EEC (24V), SCALANCE X302-7 EEC (24V, coated), SCALANCE X302-7 EEC (2x 230V), SCALANCE X302-7 EEC (2x 230V, coated), SCALANCE X302-7 EEC (2x 24V), SCALANCE X302-7 EEC (2x 24V, coated), SCALANCE X304-2FE, SCALANCE X306-1LD FE, SCALANCE X307-2 EEC (230V), SCALANCE X307-2 EEC (230V, coated), SCALANCE X307-2 EEC (24V), SCALANCE X307-2 EEC (24V, coated), SCALANCE X307-2 EEC (2x 230V), SCALANCE X307-2 EEC (2x 230V, coated), SCALANCE X307-2 EEC (2x 24V), SCALANCE X307-2 EEC (2x 24V, coated), SCALANCE X307-3, SCALANCE X307-3, SCALANCE X307-3LD, SCALANCE X307-3LD, SCALANCE X308-2, SCALANCE X308-2, SCALANCE X308-2LD, SCALANCE X308-2LD, SCALANCE X308-2LH, SCALANCE X308-2LH, SCALANCE X308-2LH+, SCALANCE X308-2LH+, SCALANCE X308-2M, SCALANCE X308-2M, SCALANCE X308-2M PoE, SCALANCE X308-2M PoE, SCALANCE X308-2M TS, SCALANCE X308-2M TS, SCALANCE X310, SCALANCE X310, SCALANCE X310FE, SCALANCE X310FE, SCALANCE X320-1 FE, SCALANCE X320-1-2LD FE, SCALANCE X408-2, SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M TS (24V), SCALANCE XR324-12M TS (24V), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M PoE (230V, ports on front), SCALANCE XR324-4M PoE (230V, ports on rear), SCALANCE XR324-4M PoE (24V, ports on front), SCALANCE XR324-4M PoE (24V, ports on rear), SCALANCE XR324-4M PoE TS (24V, ports on front), SIPLUS NET SCALANCE X308-2. The handling of arguments such as IP addresses in the CLI of affected devices is prone to buffer overflows. This could allow an authenticated remote attacker to execute arbitrary code on the device."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "CWE-121: Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-04-12T09:07:47",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-836527.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2022-25753",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "SCALANCE X302-7 EEC (230V)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X302-7 EEC (230V, coated)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X302-7 EEC (24V)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X302-7 EEC (24V, coated)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X302-7 EEC (2x 230V)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X302-7 EEC (2x 230V, coated)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X302-7 EEC (2x 24V)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X302-7 EEC (2x 24V, coated)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X304-2FE",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X306-1LD FE",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X307-2 EEC (230V)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X307-2 EEC (230V, coated)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X307-2 EEC (24V)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X307-2 EEC (24V, coated)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X307-2 EEC (2x 230V)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X307-2 EEC (2x 230V, coated)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X307-2 EEC (2x 24V)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X307-2 EEC (2x 24V, coated)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X307-3",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X307-3",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X307-3LD",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X307-3LD",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2LD",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2LD",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2LH",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2LH",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2LH+",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2LH+",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2M",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2M",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2M PoE",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2M PoE",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2M TS",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2M TS",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X310",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X310",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X310FE",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X310FE",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X320-1 FE",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X320-1-2LD FE",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X408-2",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-12M (230V, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-12M (230V, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-12M (230V, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-12M (230V, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-12M (24V, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-12M (24V, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-12M (24V, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-12M (24V, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-12M TS (24V)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-12M TS (24V)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (24V, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (24V, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (24V, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (24V, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (2x 24V, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (2x 24V, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (2x 24V, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (2x 24V, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M PoE (230V, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M PoE (230V, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M PoE (24V, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M PoE (24V, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M PoE TS (24V, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIPLUS NET SCALANCE X308-2",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in SCALANCE X302-7 EEC (230V), SCALANCE X302-7 EEC (230V, coated), SCALANCE X302-7 EEC (24V), SCALANCE X302-7 EEC (24V, coated), SCALANCE X302-7 EEC (2x 230V), SCALANCE X302-7 EEC (2x 230V, coated), SCALANCE X302-7 EEC (2x 24V), SCALANCE X302-7 EEC (2x 24V, coated), SCALANCE X304-2FE, SCALANCE X306-1LD FE, SCALANCE X307-2 EEC (230V), SCALANCE X307-2 EEC (230V, coated), SCALANCE X307-2 EEC (24V), SCALANCE X307-2 EEC (24V, coated), SCALANCE X307-2 EEC (2x 230V), SCALANCE X307-2 EEC (2x 230V, coated), SCALANCE X307-2 EEC (2x 24V), SCALANCE X307-2 EEC (2x 24V, coated), SCALANCE X307-3, SCALANCE X307-3, SCALANCE X307-3LD, SCALANCE X307-3LD, SCALANCE X308-2, SCALANCE X308-2, SCALANCE X308-2LD, SCALANCE X308-2LD, SCALANCE X308-2LH, SCALANCE X308-2LH, SCALANCE X308-2LH+, SCALANCE X308-2LH+, SCALANCE X308-2M, SCALANCE X308-2M, SCALANCE X308-2M PoE, SCALANCE X308-2M PoE, SCALANCE X308-2M TS, SCALANCE X308-2M TS, SCALANCE X310, SCALANCE X310, SCALANCE X310FE, SCALANCE X310FE, SCALANCE X320-1 FE, SCALANCE X320-1-2LD FE, SCALANCE X408-2, SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M TS (24V), SCALANCE XR324-12M TS (24V), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M PoE (230V, ports on front), SCALANCE XR324-4M PoE (230V, ports on rear), SCALANCE XR324-4M PoE (24V, ports on front), SCALANCE XR324-4M PoE (24V, ports on rear), SCALANCE XR324-4M PoE TS (24V, ports on front), SIPLUS NET SCALANCE X308-2. The handling of arguments such as IP addresses in the CLI of affected devices is prone to buffer overflows. This could allow an authenticated remote attacker to execute arbitrary code on the device."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-121: Stack-based Buffer Overflow"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-836527.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-836527.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2022-25753",
    "datePublished": "2022-04-12T09:07:47",
    "dateReserved": "2022-02-22T00:00:00",
    "dateUpdated": "2024-08-03T04:49:43.901Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2020-28400
Vulnerability from cvelistv5
Published
2021-07-13 11:02
Modified
2024-08-04 16:33
Summary
Affected devices contain a vulnerability that allows an unauthenticated attacker to trigger a denial-of-service condition. The vulnerability can be triggered if a large amount of DCP reset packets are sent to the device.
Impacted products
VendorProduct
SiemensDevelopment/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller
SiemensDevelopment/Evaluation Kits for PROFINET IO: EK-ERTEC 200
SiemensDevelopment/Evaluation Kits for PROFINET IO: EK-ERTEC 200P
SiemensRUGGEDCOM RM1224 family
SiemensSCALANCE M804PB
SiemensSCALANCE M812-1 ADSL-Router (Annex A)
SiemensSCALANCE M812-1 ADSL-Router (Annex B)
SiemensSCALANCE M816-1 ADSL-Router (Annex A)
SiemensSCALANCE M816-1 ADSL-Router (Annex B)
SiemensSCALANCE M826-2 SHDSL-Router
SiemensSCALANCE M874-2
SiemensSCALANCE M874-3
SiemensSCALANCE M876-3 (EVDO)
SiemensSCALANCE M876-3 (ROK)
SiemensSCALANCE M876-4 (EU)
SiemensSCALANCE M876-4 (NAM)
SiemensSCALANCE S615
SiemensSCALANCE W-700 IEEE 802.11n family
SiemensSCALANCE W1748-1 M12
SiemensSCALANCE W1748-1 M12
SiemensSCALANCE W1788-1 M12
SiemensSCALANCE W1788-2 EEC M12
SiemensSCALANCE W1788-2 M12
SiemensSCALANCE W1788-2IA M12
SiemensSCALANCE X200-4P IRT
SiemensSCALANCE X201-3P IRT
SiemensSCALANCE X201-3P IRT PRO
SiemensSCALANCE X202-2IRT
SiemensSCALANCE X202-2P IRT
SiemensSCALANCE X202-2P IRT PRO
SiemensSCALANCE X204-2
SiemensSCALANCE X204-2FM
SiemensSCALANCE X204-2LD
SiemensSCALANCE X204-2LD TS
SiemensSCALANCE X204-2TS
SiemensSCALANCE X204IRT
SiemensSCALANCE X204IRT PRO
SiemensSCALANCE X206-1
SiemensSCALANCE X206-1LD (incl. SIPLUS NET variant)
SiemensSCALANCE X208 (incl. SIPLUS NET variant)
SiemensSCALANCE X208PRO
SiemensSCALANCE X212-2
SiemensSCALANCE X212-2LD
SiemensSCALANCE X216
SiemensSCALANCE X224
SiemensSCALANCE X302-7 EEC (230V, coated)
SiemensSCALANCE X302-7 EEC (230V)
SiemensSCALANCE X302-7 EEC (24V, coated)
SiemensSCALANCE X302-7 EEC (24V)
SiemensSCALANCE X302-7 EEC (2x 230V, coated)
SiemensSCALANCE X302-7 EEC (2x 230V)
SiemensSCALANCE X302-7 EEC (2x 24V, coated)
SiemensSCALANCE X302-7 EEC (2x 24V)
SiemensSCALANCE X304-2FE
SiemensSCALANCE X306-1LD FE
SiemensSCALANCE X307-2 EEC (230V, coated)
SiemensSCALANCE X307-2 EEC (230V)
SiemensSCALANCE X307-2 EEC (24V, coated)
SiemensSCALANCE X307-2 EEC (24V)
SiemensSCALANCE X307-2 EEC (2x 230V, coated)
SiemensSCALANCE X307-2 EEC (2x 230V)
SiemensSCALANCE X307-2 EEC (2x 24V, coated)
SiemensSCALANCE X307-2 EEC (2x 24V)
SiemensSCALANCE X307-3
SiemensSCALANCE X307-3
SiemensSCALANCE X307-3LD
SiemensSCALANCE X307-3LD
SiemensSCALANCE X308-2
SiemensSCALANCE X308-2
SiemensSCALANCE X308-2LD
SiemensSCALANCE X308-2LD
SiemensSCALANCE X308-2LH
SiemensSCALANCE X308-2LH
SiemensSCALANCE X308-2LH+
SiemensSCALANCE X308-2LH+
SiemensSCALANCE X308-2M
SiemensSCALANCE X308-2M
SiemensSCALANCE X308-2M PoE
SiemensSCALANCE X308-2M PoE
SiemensSCALANCE X308-2M TS
SiemensSCALANCE X308-2M TS
SiemensSCALANCE X310
SiemensSCALANCE X310
SiemensSCALANCE X310FE
SiemensSCALANCE X310FE
SiemensSCALANCE X320-1 FE
SiemensSCALANCE X320-1-2LD FE
SiemensSCALANCE X408-2
SiemensSCALANCE XB-200
SiemensSCALANCE XC-200
SiemensSCALANCE XF-200BA
SiemensSCALANCE XF201-3P IRT
SiemensSCALANCE XF202-2P IRT
SiemensSCALANCE XF204
SiemensSCALANCE XF204-2 (incl. SIPLUS NET variant)
SiemensSCALANCE XF204-2BA IRT
SiemensSCALANCE XF204IRT
SiemensSCALANCE XF206-1
SiemensSCALANCE XF208
SiemensSCALANCE XM-400 Family
SiemensSCALANCE XP-200
SiemensSCALANCE XR324-12M (230V, ports on front)
SiemensSCALANCE XR324-12M (230V, ports on front)
SiemensSCALANCE XR324-12M (230V, ports on rear)
SiemensSCALANCE XR324-12M (230V, ports on rear)
SiemensSCALANCE XR324-12M (24V, ports on front)
SiemensSCALANCE XR324-12M (24V, ports on front)
SiemensSCALANCE XR324-12M (24V, ports on rear)
SiemensSCALANCE XR324-12M (24V, ports on rear)
SiemensSCALANCE XR324-12M TS (24V)
SiemensSCALANCE XR324-12M TS (24V)
SiemensSCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)
SiemensSCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)
SiemensSCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)
SiemensSCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)
SiemensSCALANCE XR324-4M EEC (24V, ports on front)
SiemensSCALANCE XR324-4M EEC (24V, ports on front)
SiemensSCALANCE XR324-4M EEC (24V, ports on rear)
SiemensSCALANCE XR324-4M EEC (24V, ports on rear)
SiemensSCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)
SiemensSCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)
SiemensSCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)
SiemensSCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)
SiemensSCALANCE XR324-4M EEC (2x 24V, ports on front)
SiemensSCALANCE XR324-4M EEC (2x 24V, ports on front)
SiemensSCALANCE XR324-4M EEC (2x 24V, ports on rear)
SiemensSCALANCE XR324-4M EEC (2x 24V, ports on rear)
SiemensSCALANCE XR324-4M PoE (230V, ports on front)
SiemensSCALANCE XR324-4M PoE (230V, ports on rear)
SiemensSCALANCE XR324-4M PoE (24V, ports on front)
SiemensSCALANCE XR324-4M PoE (24V, ports on rear)
SiemensSCALANCE XR324-4M PoE TS (24V, ports on front)
SiemensSCALANCE XR500
SiemensSIMATIC CFU DIQ
SiemensSIMATIC CFU PA
SiemensSIMATIC CM 1542-1
SiemensSIMATIC CP 1626
SiemensSIMATIC CP1616/CP1604
SiemensSIMATIC IE/PB-LINK
SiemensSIMATIC MV540 H
SiemensSIMATIC MV540 S
SiemensSIMATIC MV550 H
SiemensSIMATIC MV550 S
SiemensSIMATIC MV560 U
SiemensSIMATIC MV560 X
SiemensSIMATIC NET DK-16xx PN IO
SiemensSIMATIC Power Line Booster PLB, Base Module
SiemensSIMATIC PROFINET Driver
SiemensSIMATIC S7-1200 CPU family (incl. SIPLUS variants)
SiemensSIMOCODE pro V Ethernet/IP (incl. SIPLUS variants)
SiemensSIMOCODE pro V PROFINET (incl. SIPLUS variants)
SiemensSIPLUS NET SCALANCE X308-2
SiemensSOFTNET-IE PNIO
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:seimens:scalance_m812-1_adsl-router_annex_b:0:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "scalance_m812-1_adsl-router_annex_b",
            "vendor": "seimens",
            "versions": [
              {
                "status": "affected",
                "version": "0"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:siemens:development_evaluation_kits_for_profinet_io_dk_standard_ethernet_controller:0:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "development_evaluation_kits_for_profinet_io_dk_standard_ethernet_controller",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:siemens:development_evaluation_kits_for_profinet_io_ek_ertec_200:0:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "development_evaluation_kits_for_profinet_io_ek_ertec_200",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:siemens:development_evaluation_kits_for_profinet_io_ek_ertec_200p:0:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "development_evaluation_kits_for_profinet_io_ek_ertec_200p",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v4.7",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:siemens:ruggedcom_rm1224:0:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ruggedcom_rm1224",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v6.4",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:siemens:scalance_m804pb:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "scalance_m804pb",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v6.4",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:seimens:scalance_m812-1_adsl-router_annex_a:0:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "scalance_m812-1_adsl-router_annex_a",
            "vendor": "seimens",
            "versions": [
              {
                "lessThan": "v6.4",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:seimens:scalance_m812-1_adsl-router_annex_b:0:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "scalance_m812-1_adsl-router_annex_b",
            "vendor": "seimens",
            "versions": [
              {
                "lessThan": "6.4",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:siemens:scalance_m816_1_adsl_router_annex_a:0:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "scalance_m816_1_adsl_router_annex_a",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v6.4",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:siemens:scalance_m816-1_adsl-router_annex_b:0:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "scalance_m816-1_adsl-router_annex_b",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v6.4",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:siemens:scalance_m826-2_shdsl-router:0:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "scalance_m826-2_shdsl-router",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v6.4",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:siemens:scalence_m874_2:0:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "scalence_m874_2",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v6.4",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:siemens:scalence_m874_3:0:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "scalence_m874_3",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v6.4",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:siemens:scalance_m876_3_evdo:0:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "scalance_m876_3_evdo",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v6.4",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:siemens:scalance_m876_3_rok:0:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "scalance_m876_3_rok",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "6.4",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:siemens:scalance_m876_4_eu:0:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "scalance_m876_4_eu",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "6.4",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:siemens:scalance_m876_4_nam:0:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "scalance_m876_4_nam",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v6.4",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:siemens:scalance_s615:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "scalance_s615",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v6.4",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:siemens:scalance_w700_ieee_802.11n_family:0:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "scalance_w700_ieee_802.11n_family",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:siemens:scalance_w1748_1_m12:0:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "scalance_w1748_1_m12",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v3.0.0",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:siemens:scalance_w1788_1_m12:0:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "scalance_w1788_1_m12",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v3.0.0",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:siemens:scalance_w1788_2_eec_m12:0:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "scalance_w1788_2_eec_m12",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v3.0.0",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:siemens:scalance_w1788_2_m12:0:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "scalance_w1788_2_m12",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v3.0.0",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:siemens:scalance_w1788_2ia_m12:0:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "scalance_w1788_2ia_m12",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v3.0.0",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:siemens:scalance_x200_4p_irt:0:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "scalance_x200_4p_irt",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v5.5.0",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:siemens:scalance_x201_3p_irt:0.0:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "scalance_x201_3p_irt",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v5.5.0",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:siemens:scalance_x201_3p_irt_pro:0:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "scalance_x201_3p_irt_pro",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v5.5.0",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:siemens:scalancce_x202_2p_irt:0:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "scalancce_x202_2p_irt",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v5.5.0",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:siemens:scalence_202_2p_irt_pro:0:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "scalence_202_2p_irt_pro",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v5.5.0",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:siemens:scalancce_x204_2:0:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "scalancce_x204_2",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v5.25",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:siemens:scalence_x204_2fm:0:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "scalence_x204_2fm",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v5.25",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:siemens:scalence_x204_2ld:0:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "scalence_x204_2ld",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v5.25",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:siemens:scalence_x204_2ld_ts:0:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "scalence_x204_2ld_ts",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v5.25",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:siemens:scalence_x204_2ts:0:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "scalence_x204_2ts",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v5.25",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2020-28400",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-06-13T18:59:11.953107Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-07-24T18:07:44.485Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T16:33:59.218Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-599968.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-194-03"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/html/ssa-599968.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RM1224 family",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All Versions \u003c V6.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M804PB",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All Versions \u003c V6.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M812-1 ADSL-Router (Annex A)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All Versions \u003c V6.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M812-1 ADSL-Router (Annex B)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All Versions \u003c V6.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M816-1 ADSL-Router (Annex A)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All Versions \u003c V6.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M816-1 ADSL-Router (Annex B)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All Versions \u003c V6.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M826-2 SHDSL-Router",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All Versions \u003c V6.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M874-2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All Versions \u003c V6.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M874-3",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All Versions \u003c V6.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M876-3 (EVDO)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All Versions \u003c V6.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M876-3 (ROK)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All Versions \u003c V6.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M876-4 (EU)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All Versions \u003c V6.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M876-4 (NAM)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All Versions \u003c V6.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE S615",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All Versions \u003c V6.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W-700 IEEE 802.11n family",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W1748-1 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W1748-1 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W1788-1 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W1788-2 EEC M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W1788-2 M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W1788-2IA M12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X200-4P IRT",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All Versions \u003c V5.5.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X201-3P IRT",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All Versions \u003c V5.5.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X201-3P IRT PRO",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All Versions \u003c V5.5.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X202-2IRT",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All Versions \u003c V5.5.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X202-2P IRT",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All Versions \u003c V5.5.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X202-2P IRT PRO",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All Versions \u003c V5.5.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X204-2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.2.5"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X204-2FM",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.2.5"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X204-2LD",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.2.5"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X204-2LD TS",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.2.5"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X204-2TS",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.2.5"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X204IRT",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All Versions \u003c V5.5.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X204IRT PRO",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All Versions \u003c V5.5.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X206-1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.2.5"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X206-1LD (incl. SIPLUS NET variant)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.2.5"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X208 (incl. SIPLUS NET variant)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.2.5"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X208PRO",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.2.5"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X212-2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.2.5"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X212-2LD",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.2.5"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X216",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.2.5"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X224",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.2.5"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X302-7 EEC (230V, coated)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X302-7 EEC (230V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X302-7 EEC (24V, coated)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X302-7 EEC (24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X302-7 EEC (2x 230V, coated)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X302-7 EEC (2x 230V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X302-7 EEC (2x 24V, coated)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X302-7 EEC (2x 24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X304-2FE",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X306-1LD FE",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X307-2 EEC (230V, coated)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X307-2 EEC (230V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X307-2 EEC (24V, coated)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X307-2 EEC (24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X307-2 EEC (2x 230V, coated)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X307-2 EEC (2x 230V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X307-2 EEC (2x 24V, coated)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X307-2 EEC (2x 24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X307-3",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X307-3",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X307-3LD",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X307-3LD",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X308-2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X308-2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X308-2LD",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X308-2LD",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X308-2LH",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X308-2LH",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X308-2LH+",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X308-2LH+",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X308-2M",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X308-2M",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X308-2M PoE",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X308-2M PoE",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X308-2M TS",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X308-2M TS",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X310",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X310",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X310FE",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X310FE",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X320-1 FE",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X320-1-2LD FE",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X408-2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XB-200",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XC-200",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XF-200BA",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XF201-3P IRT",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All Versions \u003c V5.5.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XF202-2P IRT",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All Versions \u003c V5.5.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XF204",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.2.5"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XF204-2 (incl. SIPLUS NET variant)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.2.5"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XF204-2BA IRT",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All Versions \u003c V5.5.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XF204IRT",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All Versions \u003c V5.5.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XF206-1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.2.5"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XF208",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.2.5"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XM-400 Family",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.3.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XP-200",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-12M (230V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-12M (230V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-12M (230V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-12M (230V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-12M (24V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-12M (24V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-12M (24V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-12M (24V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-12M TS (24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-12M TS (24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-4M EEC (24V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-4M EEC (24V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-4M EEC (24V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-4M EEC (24V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-4M EEC (2x 24V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-4M EEC (2x 24V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-4M EEC (2x 24V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-4M EEC (2x 24V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-4M PoE (230V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-4M PoE (230V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-4M PoE (24V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-4M PoE (24V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-4M PoE TS (24V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR500",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.3.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CFU DIQ",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.0.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CFU PA",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.0.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CM 1542-1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1626",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP1616/CP1604",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All Versions \u003e= V2.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC IE/PB-LINK",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "V3",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC MV540 H",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC MV540 S",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC MV550 H",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC MV550 S",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC MV560 U",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC MV560 X",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC NET DK-16xx PN IO",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All Versions \u003e= V2.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC Power Line Booster PLB, Base Module",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC PROFINET Driver",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1200 CPU family (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All Versions \u003c V4.5"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMOCODE pro V Ethernet/IP (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V1.1.3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMOCODE pro V PROFINET (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.1.3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS NET SCALANCE X308-2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SOFTNET-IE PNIO",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Affected devices contain a vulnerability that allows an unauthenticated attacker to trigger a denial-of-service condition. The vulnerability can be triggered if a large amount of DCP reset packets are sent to the device."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-770",
              "description": "CWE-770: Allocation of Resources Without Limits or Throttling",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-06-11T14:19:34.962Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-599968.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-194-03"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-599968.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2020-28400",
    "datePublished": "2021-07-13T11:02:49",
    "dateReserved": "2020-11-10T00:00:00",
    "dateUpdated": "2024-08-04T16:33:59.218Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2019-13933
Vulnerability from cvelistv5
Published
2020-01-16 00:00
Modified
2024-08-05 00:05
Severity
Summary
A vulnerability has been identified in SCALANCE X204RNA (HSR), SCALANCE X204RNA (PRP), SCALANCE X204RNA EEC (HSR), SCALANCE X204RNA EEC (PRP), SCALANCE X204RNA EEC (PRP/HSR), SCALANCE X302-7 EEC (230V), SCALANCE X302-7 EEC (230V, coated), SCALANCE X302-7 EEC (24V), SCALANCE X302-7 EEC (24V, coated), SCALANCE X302-7 EEC (2x 230V), SCALANCE X302-7 EEC (2x 230V, coated), SCALANCE X302-7 EEC (2x 24V), SCALANCE X302-7 EEC (2x 24V, coated), SCALANCE X304-2FE, SCALANCE X306-1LD FE, SCALANCE X307-2 EEC (230V), SCALANCE X307-2 EEC (230V, coated), SCALANCE X307-2 EEC (24V), SCALANCE X307-2 EEC (24V, coated), SCALANCE X307-2 EEC (2x 230V), SCALANCE X307-2 EEC (2x 230V, coated), SCALANCE X307-2 EEC (2x 24V), SCALANCE X307-2 EEC (2x 24V, coated), SCALANCE X307-3, SCALANCE X307-3, SCALANCE X307-3LD, SCALANCE X307-3LD, SCALANCE X308-2, SCALANCE X308-2, SCALANCE X308-2LD, SCALANCE X308-2LD, SCALANCE X308-2LH, SCALANCE X308-2LH, SCALANCE X308-2LH+, SCALANCE X308-2LH+, SCALANCE X308-2M, SCALANCE X308-2M, SCALANCE X308-2M PoE, SCALANCE X308-2M PoE, SCALANCE X308-2M TS, SCALANCE X308-2M TS, SCALANCE X310, SCALANCE X310, SCALANCE X310FE, SCALANCE X310FE, SCALANCE X320-1 FE, SCALANCE X320-1-2LD FE, SCALANCE X408-2, SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M TS (24V), SCALANCE XR324-12M TS (24V), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M PoE (230V, ports on front), SCALANCE XR324-4M PoE (230V, ports on rear), SCALANCE XR324-4M PoE (24V, ports on front), SCALANCE XR324-4M PoE (24V, ports on rear), SCALANCE XR324-4M PoE TS (24V, ports on front), SIPLUS NET SCALANCE X308-2. Affected devices contain a vulnerability that allows an unauthenticated attacker to violate access-control rules. The vulnerability can be triggered by sending GET request to specific uniform resource locator on the web configuration interface of the device. The security vulnerability could be exploited by an attacker with network access to the affected systems. An attacker could use the vulnerability to obtain sensitive information or change the device configuration. At the time of advisory publication no public exploitation of this security vulnerability was known.
Impacted products
VendorProduct
SiemensSCALANCE X204RNA (HSR)
SiemensSCALANCE X204RNA (PRP)
SiemensSCALANCE X204RNA EEC (HSR)
SiemensSCALANCE X204RNA EEC (PRP)
SiemensSCALANCE X204RNA EEC (PRP/HSR)
SiemensSCALANCE X302-7 EEC (230V)
SiemensSCALANCE X302-7 EEC (230V, coated)
SiemensSCALANCE X302-7 EEC (24V)
SiemensSCALANCE X302-7 EEC (24V, coated)
SiemensSCALANCE X302-7 EEC (2x 230V)
SiemensSCALANCE X302-7 EEC (2x 230V, coated)
SiemensSCALANCE X302-7 EEC (2x 24V)
SiemensSCALANCE X302-7 EEC (2x 24V, coated)
SiemensSCALANCE X304-2FE
SiemensSCALANCE X306-1LD FE
SiemensSCALANCE X307-2 EEC (230V)
SiemensSCALANCE X307-2 EEC (230V, coated)
SiemensSCALANCE X307-2 EEC (24V)
SiemensSCALANCE X307-2 EEC (24V, coated)
SiemensSCALANCE X307-2 EEC (2x 230V)
SiemensSCALANCE X307-2 EEC (2x 230V, coated)
SiemensSCALANCE X307-2 EEC (2x 24V)
SiemensSCALANCE X307-2 EEC (2x 24V, coated)
SiemensSCALANCE X307-3
SiemensSCALANCE X307-3
SiemensSCALANCE X307-3LD
SiemensSCALANCE X307-3LD
SiemensSCALANCE X308-2
SiemensSCALANCE X308-2
SiemensSCALANCE X308-2LD
SiemensSCALANCE X308-2LD
SiemensSCALANCE X308-2LH
SiemensSCALANCE X308-2LH
SiemensSCALANCE X308-2LH+
SiemensSCALANCE X308-2LH+
SiemensSCALANCE X308-2M
SiemensSCALANCE X308-2M
SiemensSCALANCE X308-2M PoE
SiemensSCALANCE X308-2M PoE
SiemensSCALANCE X308-2M TS
SiemensSCALANCE X308-2M TS
SiemensSCALANCE X310
SiemensSCALANCE X310
SiemensSCALANCE X310FE
SiemensSCALANCE X310FE
SiemensSCALANCE X320-1 FE
SiemensSCALANCE X320-1-2LD FE
SiemensSCALANCE X408-2
SiemensSCALANCE XR324-12M (230V, ports on front)
SiemensSCALANCE XR324-12M (230V, ports on front)
SiemensSCALANCE XR324-12M (230V, ports on rear)
SiemensSCALANCE XR324-12M (230V, ports on rear)
SiemensSCALANCE XR324-12M (24V, ports on front)
SiemensSCALANCE XR324-12M (24V, ports on front)
SiemensSCALANCE XR324-12M (24V, ports on rear)
SiemensSCALANCE XR324-12M (24V, ports on rear)
SiemensSCALANCE XR324-12M TS (24V)
SiemensSCALANCE XR324-12M TS (24V)
SiemensSCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)
SiemensSCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)
SiemensSCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)
SiemensSCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)
SiemensSCALANCE XR324-4M EEC (24V, ports on front)
SiemensSCALANCE XR324-4M EEC (24V, ports on front)
SiemensSCALANCE XR324-4M EEC (24V, ports on rear)
SiemensSCALANCE XR324-4M EEC (24V, ports on rear)
SiemensSCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)
SiemensSCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)
SiemensSCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)
SiemensSCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)
SiemensSCALANCE XR324-4M EEC (2x 24V, ports on front)
SiemensSCALANCE XR324-4M EEC (2x 24V, ports on front)
SiemensSCALANCE XR324-4M EEC (2x 24V, ports on rear)
SiemensSCALANCE XR324-4M EEC (2x 24V, ports on rear)
SiemensSCALANCE XR324-4M PoE (230V, ports on front)
SiemensSCALANCE XR324-4M PoE (230V, ports on rear)
SiemensSCALANCE XR324-4M PoE (24V, ports on front)
SiemensSCALANCE XR324-4M PoE (24V, ports on rear)
SiemensSCALANCE XR324-4M PoE TS (24V, ports on front)
SiemensSIPLUS NET SCALANCE X308-2
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T00:05:43.965Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-443566.pdf"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.us-cert.gov/ics/advisories/icsa-20-014-03"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "SCALANCE X204RNA (HSR)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.7"
            }
          ]
        },
        {
          "product": "SCALANCE X204RNA (PRP)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.7"
            }
          ]
        },
        {
          "product": "SCALANCE X204RNA EEC (HSR)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.7"
            }
          ]
        },
        {
          "product": "SCALANCE X204RNA EEC (PRP)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.7"
            }
          ]
        },
        {
          "product": "SCALANCE X204RNA EEC (PRP/HSR)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.7"
            }
          ]
        },
        {
          "product": "SCALANCE X302-7 EEC (230V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE X302-7 EEC (230V, coated)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE X302-7 EEC (24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE X302-7 EEC (24V, coated)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE X302-7 EEC (2x 230V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE X302-7 EEC (2x 230V, coated)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE X302-7 EEC (2x 24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE X302-7 EEC (2x 24V, coated)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE X304-2FE",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE X306-1LD FE",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE X307-2 EEC (230V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE X307-2 EEC (230V, coated)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE X307-2 EEC (24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE X307-2 EEC (24V, coated)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE X307-2 EEC (2x 230V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE X307-2 EEC (2x 230V, coated)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE X307-2 EEC (2x 24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE X307-2 EEC (2x 24V, coated)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE X307-3",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE X307-3",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE X307-3LD",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE X307-3LD",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2LD",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2LD",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2LH",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2LH",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2LH+",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2LH+",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2M",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2M",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2M PoE",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2M PoE",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2M TS",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2M TS",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE X310",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE X310",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE X310FE",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE X310FE",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE X320-1 FE",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE X320-1-2LD FE",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE X408-2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-12M (230V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-12M (230V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-12M (230V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-12M (230V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-12M (24V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-12M (24V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-12M (24V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-12M (24V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-12M TS (24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-12M TS (24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (24V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (24V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (24V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (24V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (2x 24V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (2x 24V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (2x 24V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (2x 24V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M PoE (230V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M PoE (230V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M PoE (24V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M PoE (24V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M PoE TS (24V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SIPLUS NET SCALANCE X308-2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in SCALANCE X204RNA (HSR), SCALANCE X204RNA (PRP), SCALANCE X204RNA EEC (HSR), SCALANCE X204RNA EEC (PRP), SCALANCE X204RNA EEC (PRP/HSR), SCALANCE X302-7 EEC (230V), SCALANCE X302-7 EEC (230V, coated), SCALANCE X302-7 EEC (24V), SCALANCE X302-7 EEC (24V, coated), SCALANCE X302-7 EEC (2x 230V), SCALANCE X302-7 EEC (2x 230V, coated), SCALANCE X302-7 EEC (2x 24V), SCALANCE X302-7 EEC (2x 24V, coated), SCALANCE X304-2FE, SCALANCE X306-1LD FE, SCALANCE X307-2 EEC (230V), SCALANCE X307-2 EEC (230V, coated), SCALANCE X307-2 EEC (24V), SCALANCE X307-2 EEC (24V, coated), SCALANCE X307-2 EEC (2x 230V), SCALANCE X307-2 EEC (2x 230V, coated), SCALANCE X307-2 EEC (2x 24V), SCALANCE X307-2 EEC (2x 24V, coated), SCALANCE X307-3, SCALANCE X307-3, SCALANCE X307-3LD, SCALANCE X307-3LD, SCALANCE X308-2, SCALANCE X308-2, SCALANCE X308-2LD, SCALANCE X308-2LD, SCALANCE X308-2LH, SCALANCE X308-2LH, SCALANCE X308-2LH+, SCALANCE X308-2LH+, SCALANCE X308-2M, SCALANCE X308-2M, SCALANCE X308-2M PoE, SCALANCE X308-2M PoE, SCALANCE X308-2M TS, SCALANCE X308-2M TS, SCALANCE X310, SCALANCE X310, SCALANCE X310FE, SCALANCE X310FE, SCALANCE X320-1 FE, SCALANCE X320-1-2LD FE, SCALANCE X408-2, SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M TS (24V), SCALANCE XR324-12M TS (24V), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M PoE (230V, ports on front), SCALANCE XR324-4M PoE (230V, ports on rear), SCALANCE XR324-4M PoE (24V, ports on front), SCALANCE XR324-4M PoE (24V, ports on rear), SCALANCE XR324-4M PoE TS (24V, ports on front), SIPLUS NET SCALANCE X308-2. Affected devices contain a vulnerability that allows an unauthenticated attacker to violate access-control rules. The vulnerability can be triggered by sending GET request to specific uniform resource locator on the web configuration interface of the device. The security vulnerability could be exploited by an attacker with network access to the affected systems. An attacker could use the vulnerability to obtain sensitive information or change the device configuration. At the time of advisory publication no public exploitation of this security vulnerability was known."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-306",
              "description": "CWE-306: Missing Authentication for Critical Function",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-12-13T00:00:00",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-443566.pdf"
        },
        {
          "url": "https://www.us-cert.gov/ics/advisories/icsa-20-014-03"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2019-13933",
    "datePublished": "2020-01-16T00:00:00",
    "dateReserved": "2019-07-18T00:00:00",
    "dateUpdated": "2024-08-05T00:05:43.965Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2022-25756
Vulnerability from cvelistv5
Published
2022-04-12 09:07
Modified
2024-08-03 04:49
Severity
Summary
A vulnerability has been identified in SCALANCE X302-7 EEC (230V), SCALANCE X302-7 EEC (230V, coated), SCALANCE X302-7 EEC (24V), SCALANCE X302-7 EEC (24V, coated), SCALANCE X302-7 EEC (2x 230V), SCALANCE X302-7 EEC (2x 230V, coated), SCALANCE X302-7 EEC (2x 24V), SCALANCE X302-7 EEC (2x 24V, coated), SCALANCE X304-2FE, SCALANCE X306-1LD FE, SCALANCE X307-2 EEC (230V), SCALANCE X307-2 EEC (230V, coated), SCALANCE X307-2 EEC (24V), SCALANCE X307-2 EEC (24V, coated), SCALANCE X307-2 EEC (2x 230V), SCALANCE X307-2 EEC (2x 230V, coated), SCALANCE X307-2 EEC (2x 24V), SCALANCE X307-2 EEC (2x 24V, coated), SCALANCE X307-3, SCALANCE X307-3, SCALANCE X307-3LD, SCALANCE X307-3LD, SCALANCE X308-2, SCALANCE X308-2, SCALANCE X308-2LD, SCALANCE X308-2LD, SCALANCE X308-2LH, SCALANCE X308-2LH, SCALANCE X308-2LH+, SCALANCE X308-2LH+, SCALANCE X308-2M, SCALANCE X308-2M, SCALANCE X308-2M PoE, SCALANCE X308-2M PoE, SCALANCE X308-2M TS, SCALANCE X308-2M TS, SCALANCE X310, SCALANCE X310, SCALANCE X310FE, SCALANCE X310FE, SCALANCE X320-1 FE, SCALANCE X320-1-2LD FE, SCALANCE X408-2, SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M TS (24V), SCALANCE XR324-12M TS (24V), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M PoE (230V, ports on front), SCALANCE XR324-4M PoE (230V, ports on rear), SCALANCE XR324-4M PoE (24V, ports on front), SCALANCE XR324-4M PoE (24V, ports on rear), SCALANCE XR324-4M PoE TS (24V, ports on front), SIPLUS NET SCALANCE X308-2. The integrated web server could allow Cross-Site Scripting (XSS) attacks if unsuspecting users are tricked into accessing a malicious link. This can be used by an attacker to trigger a malicious request on the affected device.
Impacted products
VendorProduct
SiemensSCALANCE X302-7 EEC (230V)
SiemensSCALANCE X302-7 EEC (230V, coated)
SiemensSCALANCE X302-7 EEC (24V)
SiemensSCALANCE X302-7 EEC (24V, coated)
SiemensSCALANCE X302-7 EEC (2x 230V)
SiemensSCALANCE X302-7 EEC (2x 230V, coated)
SiemensSCALANCE X302-7 EEC (2x 24V)
SiemensSCALANCE X302-7 EEC (2x 24V, coated)
SiemensSCALANCE X304-2FE
SiemensSCALANCE X306-1LD FE
SiemensSCALANCE X307-2 EEC (230V)
SiemensSCALANCE X307-2 EEC (230V, coated)
SiemensSCALANCE X307-2 EEC (24V)
SiemensSCALANCE X307-2 EEC (24V, coated)
SiemensSCALANCE X307-2 EEC (2x 230V)
SiemensSCALANCE X307-2 EEC (2x 230V, coated)
SiemensSCALANCE X307-2 EEC (2x 24V)
SiemensSCALANCE X307-2 EEC (2x 24V, coated)
SiemensSCALANCE X307-3
SiemensSCALANCE X307-3
SiemensSCALANCE X307-3LD
SiemensSCALANCE X307-3LD
SiemensSCALANCE X308-2
SiemensSCALANCE X308-2
SiemensSCALANCE X308-2LD
SiemensSCALANCE X308-2LD
SiemensSCALANCE X308-2LH
SiemensSCALANCE X308-2LH
SiemensSCALANCE X308-2LH+
SiemensSCALANCE X308-2LH+
SiemensSCALANCE X308-2M
SiemensSCALANCE X308-2M
SiemensSCALANCE X308-2M PoE
SiemensSCALANCE X308-2M PoE
SiemensSCALANCE X308-2M TS
SiemensSCALANCE X308-2M TS
SiemensSCALANCE X310
SiemensSCALANCE X310
SiemensSCALANCE X310FE
SiemensSCALANCE X310FE
SiemensSCALANCE X320-1 FE
SiemensSCALANCE X320-1-2LD FE
SiemensSCALANCE X408-2
SiemensSCALANCE XR324-12M (230V, ports on front)
SiemensSCALANCE XR324-12M (230V, ports on front)
SiemensSCALANCE XR324-12M (230V, ports on rear)
SiemensSCALANCE XR324-12M (230V, ports on rear)
SiemensSCALANCE XR324-12M (24V, ports on front)
SiemensSCALANCE XR324-12M (24V, ports on front)
SiemensSCALANCE XR324-12M (24V, ports on rear)
SiemensSCALANCE XR324-12M (24V, ports on rear)
SiemensSCALANCE XR324-12M TS (24V)
SiemensSCALANCE XR324-12M TS (24V)
SiemensSCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)
SiemensSCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)
SiemensSCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)
SiemensSCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)
SiemensSCALANCE XR324-4M EEC (24V, ports on front)
SiemensSCALANCE XR324-4M EEC (24V, ports on front)
SiemensSCALANCE XR324-4M EEC (24V, ports on rear)
SiemensSCALANCE XR324-4M EEC (24V, ports on rear)
SiemensSCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)
SiemensSCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)
SiemensSCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)
SiemensSCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)
SiemensSCALANCE XR324-4M EEC (2x 24V, ports on front)
SiemensSCALANCE XR324-4M EEC (2x 24V, ports on front)
SiemensSCALANCE XR324-4M EEC (2x 24V, ports on rear)
SiemensSCALANCE XR324-4M EEC (2x 24V, ports on rear)
SiemensSCALANCE XR324-4M PoE (230V, ports on front)
SiemensSCALANCE XR324-4M PoE (230V, ports on rear)
SiemensSCALANCE XR324-4M PoE (24V, ports on front)
SiemensSCALANCE XR324-4M PoE (24V, ports on rear)
SiemensSCALANCE XR324-4M PoE TS (24V, ports on front)
SiemensSIPLUS NET SCALANCE X308-2
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T04:49:43.497Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-836527.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "SCALANCE X302-7 EEC (230V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X302-7 EEC (230V, coated)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X302-7 EEC (24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X302-7 EEC (24V, coated)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X302-7 EEC (2x 230V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X302-7 EEC (2x 230V, coated)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X302-7 EEC (2x 24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X302-7 EEC (2x 24V, coated)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X304-2FE",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X306-1LD FE",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X307-2 EEC (230V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X307-2 EEC (230V, coated)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X307-2 EEC (24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X307-2 EEC (24V, coated)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X307-2 EEC (2x 230V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X307-2 EEC (2x 230V, coated)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X307-2 EEC (2x 24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X307-2 EEC (2x 24V, coated)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X307-3",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X307-3",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X307-3LD",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X307-3LD",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2LD",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2LD",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2LH",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2LH",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2LH+",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2LH+",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2M",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2M",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2M PoE",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2M PoE",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2M TS",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2M TS",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X310",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X310",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X310FE",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X310FE",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X320-1 FE",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X320-1-2LD FE",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X408-2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-12M (230V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-12M (230V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-12M (230V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-12M (230V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-12M (24V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-12M (24V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-12M (24V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-12M (24V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-12M TS (24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-12M TS (24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (24V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (24V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (24V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (24V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (2x 24V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (2x 24V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (2x 24V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (2x 24V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M PoE (230V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M PoE (230V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M PoE (24V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M PoE (24V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M PoE TS (24V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SIPLUS NET SCALANCE X308-2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in SCALANCE X302-7 EEC (230V), SCALANCE X302-7 EEC (230V, coated), SCALANCE X302-7 EEC (24V), SCALANCE X302-7 EEC (24V, coated), SCALANCE X302-7 EEC (2x 230V), SCALANCE X302-7 EEC (2x 230V, coated), SCALANCE X302-7 EEC (2x 24V), SCALANCE X302-7 EEC (2x 24V, coated), SCALANCE X304-2FE, SCALANCE X306-1LD FE, SCALANCE X307-2 EEC (230V), SCALANCE X307-2 EEC (230V, coated), SCALANCE X307-2 EEC (24V), SCALANCE X307-2 EEC (24V, coated), SCALANCE X307-2 EEC (2x 230V), SCALANCE X307-2 EEC (2x 230V, coated), SCALANCE X307-2 EEC (2x 24V), SCALANCE X307-2 EEC (2x 24V, coated), SCALANCE X307-3, SCALANCE X307-3, SCALANCE X307-3LD, SCALANCE X307-3LD, SCALANCE X308-2, SCALANCE X308-2, SCALANCE X308-2LD, SCALANCE X308-2LD, SCALANCE X308-2LH, SCALANCE X308-2LH, SCALANCE X308-2LH+, SCALANCE X308-2LH+, SCALANCE X308-2M, SCALANCE X308-2M, SCALANCE X308-2M PoE, SCALANCE X308-2M PoE, SCALANCE X308-2M TS, SCALANCE X308-2M TS, SCALANCE X310, SCALANCE X310, SCALANCE X310FE, SCALANCE X310FE, SCALANCE X320-1 FE, SCALANCE X320-1-2LD FE, SCALANCE X408-2, SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M TS (24V), SCALANCE XR324-12M TS (24V), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M PoE (230V, ports on front), SCALANCE XR324-4M PoE (230V, ports on rear), SCALANCE XR324-4M PoE (24V, ports on front), SCALANCE XR324-4M PoE (24V, ports on rear), SCALANCE XR324-4M PoE TS (24V, ports on front), SIPLUS NET SCALANCE X308-2. The integrated web server could allow Cross-Site Scripting (XSS) attacks if unsuspecting users are tricked into accessing a malicious link. This can be used by an attacker to trigger a malicious request on the affected device."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-80",
              "description": "CWE-80: Improper Neutralization of Script-Related HTML Tags in a Web Page (Basic XSS)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-04-12T09:07:52",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-836527.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2022-25756",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "SCALANCE X302-7 EEC (230V)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X302-7 EEC (230V, coated)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X302-7 EEC (24V)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X302-7 EEC (24V, coated)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X302-7 EEC (2x 230V)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X302-7 EEC (2x 230V, coated)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X302-7 EEC (2x 24V)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X302-7 EEC (2x 24V, coated)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X304-2FE",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X306-1LD FE",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X307-2 EEC (230V)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X307-2 EEC (230V, coated)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X307-2 EEC (24V)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X307-2 EEC (24V, coated)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X307-2 EEC (2x 230V)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X307-2 EEC (2x 230V, coated)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X307-2 EEC (2x 24V)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X307-2 EEC (2x 24V, coated)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X307-3",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X307-3",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X307-3LD",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X307-3LD",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2LD",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2LD",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2LH",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2LH",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2LH+",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2LH+",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2M",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2M",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2M PoE",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2M PoE",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2M TS",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2M TS",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X310",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X310",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X310FE",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X310FE",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X320-1 FE",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X320-1-2LD FE",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X408-2",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-12M (230V, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-12M (230V, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-12M (230V, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-12M (230V, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-12M (24V, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-12M (24V, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-12M (24V, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-12M (24V, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-12M TS (24V)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-12M TS (24V)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (24V, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (24V, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (24V, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (24V, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (2x 24V, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (2x 24V, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (2x 24V, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (2x 24V, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M PoE (230V, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M PoE (230V, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M PoE (24V, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M PoE (24V, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M PoE TS (24V, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIPLUS NET SCALANCE X308-2",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in SCALANCE X302-7 EEC (230V), SCALANCE X302-7 EEC (230V, coated), SCALANCE X302-7 EEC (24V), SCALANCE X302-7 EEC (24V, coated), SCALANCE X302-7 EEC (2x 230V), SCALANCE X302-7 EEC (2x 230V, coated), SCALANCE X302-7 EEC (2x 24V), SCALANCE X302-7 EEC (2x 24V, coated), SCALANCE X304-2FE, SCALANCE X306-1LD FE, SCALANCE X307-2 EEC (230V), SCALANCE X307-2 EEC (230V, coated), SCALANCE X307-2 EEC (24V), SCALANCE X307-2 EEC (24V, coated), SCALANCE X307-2 EEC (2x 230V), SCALANCE X307-2 EEC (2x 230V, coated), SCALANCE X307-2 EEC (2x 24V), SCALANCE X307-2 EEC (2x 24V, coated), SCALANCE X307-3, SCALANCE X307-3, SCALANCE X307-3LD, SCALANCE X307-3LD, SCALANCE X308-2, SCALANCE X308-2, SCALANCE X308-2LD, SCALANCE X308-2LD, SCALANCE X308-2LH, SCALANCE X308-2LH, SCALANCE X308-2LH+, SCALANCE X308-2LH+, SCALANCE X308-2M, SCALANCE X308-2M, SCALANCE X308-2M PoE, SCALANCE X308-2M PoE, SCALANCE X308-2M TS, SCALANCE X308-2M TS, SCALANCE X310, SCALANCE X310, SCALANCE X310FE, SCALANCE X310FE, SCALANCE X320-1 FE, SCALANCE X320-1-2LD FE, SCALANCE X408-2, SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M TS (24V), SCALANCE XR324-12M TS (24V), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M PoE (230V, ports on front), SCALANCE XR324-4M PoE (230V, ports on rear), SCALANCE XR324-4M PoE (24V, ports on front), SCALANCE XR324-4M PoE (24V, ports on rear), SCALANCE XR324-4M PoE TS (24V, ports on front), SIPLUS NET SCALANCE X308-2. The integrated web server could allow Cross-Site Scripting (XSS) attacks if unsuspecting users are tricked into accessing a malicious link. This can be used by an attacker to trigger a malicious request on the affected device."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-80: Improper Neutralization of Script-Related HTML Tags in a Web Page (Basic XSS)"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-836527.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-836527.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2022-25756",
    "datePublished": "2022-04-12T09:07:52",
    "dateReserved": "2022-02-22T00:00:00",
    "dateUpdated": "2024-08-03T04:49:43.497Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2022-25752
Vulnerability from cvelistv5
Published
2022-04-12 09:07
Modified
2024-08-03 04:49
Severity
Summary
A vulnerability has been identified in SCALANCE X302-7 EEC (230V), SCALANCE X302-7 EEC (230V, coated), SCALANCE X302-7 EEC (24V), SCALANCE X302-7 EEC (24V, coated), SCALANCE X302-7 EEC (2x 230V), SCALANCE X302-7 EEC (2x 230V, coated), SCALANCE X302-7 EEC (2x 24V), SCALANCE X302-7 EEC (2x 24V, coated), SCALANCE X304-2FE, SCALANCE X306-1LD FE, SCALANCE X307-2 EEC (230V), SCALANCE X307-2 EEC (230V, coated), SCALANCE X307-2 EEC (24V), SCALANCE X307-2 EEC (24V, coated), SCALANCE X307-2 EEC (2x 230V), SCALANCE X307-2 EEC (2x 230V, coated), SCALANCE X307-2 EEC (2x 24V), SCALANCE X307-2 EEC (2x 24V, coated), SCALANCE X307-3, SCALANCE X307-3, SCALANCE X307-3LD, SCALANCE X307-3LD, SCALANCE X308-2, SCALANCE X308-2, SCALANCE X308-2LD, SCALANCE X308-2LD, SCALANCE X308-2LH, SCALANCE X308-2LH, SCALANCE X308-2LH+, SCALANCE X308-2LH+, SCALANCE X308-2M, SCALANCE X308-2M, SCALANCE X308-2M PoE, SCALANCE X308-2M PoE, SCALANCE X308-2M TS, SCALANCE X308-2M TS, SCALANCE X310, SCALANCE X310, SCALANCE X310FE, SCALANCE X310FE, SCALANCE X320-1 FE, SCALANCE X320-1-2LD FE, SCALANCE X408-2, SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M TS (24V), SCALANCE XR324-12M TS (24V), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M PoE (230V, ports on front), SCALANCE XR324-4M PoE (230V, ports on rear), SCALANCE XR324-4M PoE (24V, ports on front), SCALANCE XR324-4M PoE (24V, ports on rear), SCALANCE XR324-4M PoE TS (24V, ports on front), SIPLUS NET SCALANCE X308-2. The webserver of affected devices calculates session ids and nonces in an insecure manner. This could allow an unauthenticated remote attacker to brute-force session ids and hijack existing sessions.
Impacted products
VendorProduct
SiemensSCALANCE X302-7 EEC (230V)
SiemensSCALANCE X302-7 EEC (230V, coated)
SiemensSCALANCE X302-7 EEC (24V)
SiemensSCALANCE X302-7 EEC (24V, coated)
SiemensSCALANCE X302-7 EEC (2x 230V)
SiemensSCALANCE X302-7 EEC (2x 230V, coated)
SiemensSCALANCE X302-7 EEC (2x 24V)
SiemensSCALANCE X302-7 EEC (2x 24V, coated)
SiemensSCALANCE X304-2FE
SiemensSCALANCE X306-1LD FE
SiemensSCALANCE X307-2 EEC (230V)
SiemensSCALANCE X307-2 EEC (230V, coated)
SiemensSCALANCE X307-2 EEC (24V)
SiemensSCALANCE X307-2 EEC (24V, coated)
SiemensSCALANCE X307-2 EEC (2x 230V)
SiemensSCALANCE X307-2 EEC (2x 230V, coated)
SiemensSCALANCE X307-2 EEC (2x 24V)
SiemensSCALANCE X307-2 EEC (2x 24V, coated)
SiemensSCALANCE X307-3
SiemensSCALANCE X307-3
SiemensSCALANCE X307-3LD
SiemensSCALANCE X307-3LD
SiemensSCALANCE X308-2
SiemensSCALANCE X308-2
SiemensSCALANCE X308-2LD
SiemensSCALANCE X308-2LD
SiemensSCALANCE X308-2LH
SiemensSCALANCE X308-2LH
SiemensSCALANCE X308-2LH+
SiemensSCALANCE X308-2LH+
SiemensSCALANCE X308-2M
SiemensSCALANCE X308-2M
SiemensSCALANCE X308-2M PoE
SiemensSCALANCE X308-2M PoE
SiemensSCALANCE X308-2M TS
SiemensSCALANCE X308-2M TS
SiemensSCALANCE X310
SiemensSCALANCE X310
SiemensSCALANCE X310FE
SiemensSCALANCE X310FE
SiemensSCALANCE X320-1 FE
SiemensSCALANCE X320-1-2LD FE
SiemensSCALANCE X408-2
SiemensSCALANCE XR324-12M (230V, ports on front)
SiemensSCALANCE XR324-12M (230V, ports on front)
SiemensSCALANCE XR324-12M (230V, ports on rear)
SiemensSCALANCE XR324-12M (230V, ports on rear)
SiemensSCALANCE XR324-12M (24V, ports on front)
SiemensSCALANCE XR324-12M (24V, ports on front)
SiemensSCALANCE XR324-12M (24V, ports on rear)
SiemensSCALANCE XR324-12M (24V, ports on rear)
SiemensSCALANCE XR324-12M TS (24V)
SiemensSCALANCE XR324-12M TS (24V)
SiemensSCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)
SiemensSCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)
SiemensSCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)
SiemensSCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)
SiemensSCALANCE XR324-4M EEC (24V, ports on front)
SiemensSCALANCE XR324-4M EEC (24V, ports on front)
SiemensSCALANCE XR324-4M EEC (24V, ports on rear)
SiemensSCALANCE XR324-4M EEC (24V, ports on rear)
SiemensSCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)
SiemensSCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)
SiemensSCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)
SiemensSCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)
SiemensSCALANCE XR324-4M EEC (2x 24V, ports on front)
SiemensSCALANCE XR324-4M EEC (2x 24V, ports on front)
SiemensSCALANCE XR324-4M EEC (2x 24V, ports on rear)
SiemensSCALANCE XR324-4M EEC (2x 24V, ports on rear)
SiemensSCALANCE XR324-4M PoE (230V, ports on front)
SiemensSCALANCE XR324-4M PoE (230V, ports on rear)
SiemensSCALANCE XR324-4M PoE (24V, ports on front)
SiemensSCALANCE XR324-4M PoE (24V, ports on rear)
SiemensSCALANCE XR324-4M PoE TS (24V, ports on front)
SiemensSIPLUS NET SCALANCE X308-2
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T04:49:43.562Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-836527.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "SCALANCE X302-7 EEC (230V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X302-7 EEC (230V, coated)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X302-7 EEC (24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X302-7 EEC (24V, coated)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X302-7 EEC (2x 230V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X302-7 EEC (2x 230V, coated)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X302-7 EEC (2x 24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X302-7 EEC (2x 24V, coated)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X304-2FE",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X306-1LD FE",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X307-2 EEC (230V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X307-2 EEC (230V, coated)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X307-2 EEC (24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X307-2 EEC (24V, coated)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X307-2 EEC (2x 230V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X307-2 EEC (2x 230V, coated)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X307-2 EEC (2x 24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X307-2 EEC (2x 24V, coated)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X307-3",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X307-3",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X307-3LD",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X307-3LD",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2LD",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2LD",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2LH",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2LH",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2LH+",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2LH+",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2M",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2M",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2M PoE",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2M PoE",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2M TS",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2M TS",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X310",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X310",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X310FE",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X310FE",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X320-1 FE",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X320-1-2LD FE",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X408-2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-12M (230V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-12M (230V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-12M (230V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-12M (230V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-12M (24V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-12M (24V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-12M (24V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-12M (24V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-12M TS (24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-12M TS (24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (24V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (24V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (24V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (24V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (2x 24V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (2x 24V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (2x 24V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (2x 24V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M PoE (230V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M PoE (230V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M PoE (24V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M PoE (24V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M PoE TS (24V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SIPLUS NET SCALANCE X308-2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in SCALANCE X302-7 EEC (230V), SCALANCE X302-7 EEC (230V, coated), SCALANCE X302-7 EEC (24V), SCALANCE X302-7 EEC (24V, coated), SCALANCE X302-7 EEC (2x 230V), SCALANCE X302-7 EEC (2x 230V, coated), SCALANCE X302-7 EEC (2x 24V), SCALANCE X302-7 EEC (2x 24V, coated), SCALANCE X304-2FE, SCALANCE X306-1LD FE, SCALANCE X307-2 EEC (230V), SCALANCE X307-2 EEC (230V, coated), SCALANCE X307-2 EEC (24V), SCALANCE X307-2 EEC (24V, coated), SCALANCE X307-2 EEC (2x 230V), SCALANCE X307-2 EEC (2x 230V, coated), SCALANCE X307-2 EEC (2x 24V), SCALANCE X307-2 EEC (2x 24V, coated), SCALANCE X307-3, SCALANCE X307-3, SCALANCE X307-3LD, SCALANCE X307-3LD, SCALANCE X308-2, SCALANCE X308-2, SCALANCE X308-2LD, SCALANCE X308-2LD, SCALANCE X308-2LH, SCALANCE X308-2LH, SCALANCE X308-2LH+, SCALANCE X308-2LH+, SCALANCE X308-2M, SCALANCE X308-2M, SCALANCE X308-2M PoE, SCALANCE X308-2M PoE, SCALANCE X308-2M TS, SCALANCE X308-2M TS, SCALANCE X310, SCALANCE X310, SCALANCE X310FE, SCALANCE X310FE, SCALANCE X320-1 FE, SCALANCE X320-1-2LD FE, SCALANCE X408-2, SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M TS (24V), SCALANCE XR324-12M TS (24V), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M PoE (230V, ports on front), SCALANCE XR324-4M PoE (230V, ports on rear), SCALANCE XR324-4M PoE (24V, ports on front), SCALANCE XR324-4M PoE (24V, ports on rear), SCALANCE XR324-4M PoE TS (24V, ports on front), SIPLUS NET SCALANCE X308-2. The webserver of affected devices calculates session ids and nonces in an insecure manner. This could allow an unauthenticated remote attacker to brute-force session ids and hijack existing sessions."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-330",
              "description": "CWE-330: Use of Insufficiently Random Values",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-04-12T09:07:46",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-836527.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2022-25752",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "SCALANCE X302-7 EEC (230V)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X302-7 EEC (230V, coated)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X302-7 EEC (24V)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X302-7 EEC (24V, coated)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X302-7 EEC (2x 230V)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X302-7 EEC (2x 230V, coated)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X302-7 EEC (2x 24V)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X302-7 EEC (2x 24V, coated)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X304-2FE",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X306-1LD FE",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X307-2 EEC (230V)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X307-2 EEC (230V, coated)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X307-2 EEC (24V)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X307-2 EEC (24V, coated)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X307-2 EEC (2x 230V)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X307-2 EEC (2x 230V, coated)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X307-2 EEC (2x 24V)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X307-2 EEC (2x 24V, coated)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X307-3",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X307-3",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X307-3LD",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X307-3LD",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2LD",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2LD",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2LH",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2LH",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2LH+",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2LH+",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2M",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2M",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2M PoE",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2M PoE",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2M TS",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2M TS",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X310",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X310",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X310FE",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X310FE",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X320-1 FE",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X320-1-2LD FE",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X408-2",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-12M (230V, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-12M (230V, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-12M (230V, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-12M (230V, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-12M (24V, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-12M (24V, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-12M (24V, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-12M (24V, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-12M TS (24V)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-12M TS (24V)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (24V, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (24V, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (24V, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (24V, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (2x 24V, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (2x 24V, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (2x 24V, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (2x 24V, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M PoE (230V, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M PoE (230V, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M PoE (24V, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M PoE (24V, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M PoE TS (24V, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIPLUS NET SCALANCE X308-2",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in SCALANCE X302-7 EEC (230V), SCALANCE X302-7 EEC (230V, coated), SCALANCE X302-7 EEC (24V), SCALANCE X302-7 EEC (24V, coated), SCALANCE X302-7 EEC (2x 230V), SCALANCE X302-7 EEC (2x 230V, coated), SCALANCE X302-7 EEC (2x 24V), SCALANCE X302-7 EEC (2x 24V, coated), SCALANCE X304-2FE, SCALANCE X306-1LD FE, SCALANCE X307-2 EEC (230V), SCALANCE X307-2 EEC (230V, coated), SCALANCE X307-2 EEC (24V), SCALANCE X307-2 EEC (24V, coated), SCALANCE X307-2 EEC (2x 230V), SCALANCE X307-2 EEC (2x 230V, coated), SCALANCE X307-2 EEC (2x 24V), SCALANCE X307-2 EEC (2x 24V, coated), SCALANCE X307-3, SCALANCE X307-3, SCALANCE X307-3LD, SCALANCE X307-3LD, SCALANCE X308-2, SCALANCE X308-2, SCALANCE X308-2LD, SCALANCE X308-2LD, SCALANCE X308-2LH, SCALANCE X308-2LH, SCALANCE X308-2LH+, SCALANCE X308-2LH+, SCALANCE X308-2M, SCALANCE X308-2M, SCALANCE X308-2M PoE, SCALANCE X308-2M PoE, SCALANCE X308-2M TS, SCALANCE X308-2M TS, SCALANCE X310, SCALANCE X310, SCALANCE X310FE, SCALANCE X310FE, SCALANCE X320-1 FE, SCALANCE X320-1-2LD FE, SCALANCE X408-2, SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M TS (24V), SCALANCE XR324-12M TS (24V), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M PoE (230V, ports on front), SCALANCE XR324-4M PoE (230V, ports on rear), SCALANCE XR324-4M PoE (24V, ports on front), SCALANCE XR324-4M PoE (24V, ports on rear), SCALANCE XR324-4M PoE TS (24V, ports on front), SIPLUS NET SCALANCE X308-2. The webserver of affected devices calculates session ids and nonces in an insecure manner. This could allow an unauthenticated remote attacker to brute-force session ids and hijack existing sessions."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-330: Use of Insufficiently Random Values"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-836527.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-836527.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2022-25752",
    "datePublished": "2022-04-12T09:07:46",
    "dateReserved": "2022-02-22T00:00:00",
    "dateUpdated": "2024-08-03T04:49:43.562Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2019-19301
Vulnerability from cvelistv5
Published
2020-04-14 19:50
Modified
2024-08-05 02:16
Summary
A vulnerability has been identified in SCALANCE X200-4P IRT, SCALANCE X201-3P IRT, SCALANCE X201-3P IRT PRO, SCALANCE X202-2IRT, SCALANCE X202-2P IRT, SCALANCE X202-2P IRT PRO, SCALANCE X204-2, SCALANCE X204-2FM, SCALANCE X204-2LD, SCALANCE X204-2LD TS, SCALANCE X204-2TS, SCALANCE X204IRT, SCALANCE X204IRT PRO, SCALANCE X206-1, SCALANCE X206-1LD, SCALANCE X208, SCALANCE X208PRO, SCALANCE X212-2, SCALANCE X212-2LD, SCALANCE X216, SCALANCE X224, SCALANCE X302-7 EEC (230V, coated), SCALANCE X302-7 EEC (230V), SCALANCE X302-7 EEC (24V, coated), SCALANCE X302-7 EEC (24V), SCALANCE X302-7 EEC (2x 230V, coated), SCALANCE X302-7 EEC (2x 230V), SCALANCE X302-7 EEC (2x 24V, coated), SCALANCE X302-7 EEC (2x 24V), SCALANCE X304-2FE, SCALANCE X306-1LD FE, SCALANCE X307-2 EEC (230V, coated), SCALANCE X307-2 EEC (230V), SCALANCE X307-2 EEC (24V, coated), SCALANCE X307-2 EEC (24V), SCALANCE X307-2 EEC (2x 230V, coated), SCALANCE X307-2 EEC (2x 230V), SCALANCE X307-2 EEC (2x 24V, coated), SCALANCE X307-2 EEC (2x 24V), SCALANCE X307-3, SCALANCE X307-3, SCALANCE X307-3LD, SCALANCE X307-3LD, SCALANCE X308-2, SCALANCE X308-2, SCALANCE X308-2LD, SCALANCE X308-2LD, SCALANCE X308-2LH, SCALANCE X308-2LH, SCALANCE X308-2LH+, SCALANCE X308-2LH+, SCALANCE X308-2M, SCALANCE X308-2M, SCALANCE X308-2M PoE, SCALANCE X308-2M PoE, SCALANCE X308-2M TS, SCALANCE X308-2M TS, SCALANCE X310, SCALANCE X310, SCALANCE X310FE, SCALANCE X310FE, SCALANCE X320-1 FE, SCALANCE X320-1-2LD FE, SCALANCE X408-2, SCALANCE XF201-3P IRT, SCALANCE XF202-2P IRT, SCALANCE XF204, SCALANCE XF204-2, SCALANCE XF204-2BA IRT, SCALANCE XF204IRT, SCALANCE XF206-1, SCALANCE XF208, SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M TS (24V), SCALANCE XR324-12M TS (24V), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M PoE (230V, ports on front), SCALANCE XR324-4M PoE (230V, ports on rear), SCALANCE XR324-4M PoE (24V, ports on front), SCALANCE XR324-4M PoE (24V, ports on rear), SCALANCE XR324-4M PoE TS (24V, ports on front), SIMATIC CP 343-1 Advanced, SIMATIC CP 442-1 RNA, SIMATIC CP 443-1, SIMATIC CP 443-1, SIMATIC CP 443-1 Advanced, SIMATIC CP 443-1 RNA, SIMATIC RF180C, SIMATIC RF182C, SIPLUS NET CP 343-1 Advanced, SIPLUS NET CP 443-1, SIPLUS NET CP 443-1 Advanced, SIPLUS NET SCALANCE X308-2. The VxWorks-based Profinet TCP Stack can be forced to make very expensive calls for every incoming packet which can lead to a denial of service.
Impacted products
VendorProduct
SiemensSCALANCE X200-4P IRT
SiemensSCALANCE X201-3P IRT
SiemensSCALANCE X201-3P IRT PRO
SiemensSCALANCE X202-2IRT
SiemensSCALANCE X202-2P IRT
SiemensSCALANCE X202-2P IRT PRO
SiemensSCALANCE X204-2
SiemensSCALANCE X204-2FM
SiemensSCALANCE X204-2LD
SiemensSCALANCE X204-2LD TS
SiemensSCALANCE X204-2TS
SiemensSCALANCE X204IRT
SiemensSCALANCE X204IRT PRO
SiemensSCALANCE X206-1
SiemensSCALANCE X206-1LD
SiemensSCALANCE X208
SiemensSCALANCE X208PRO
SiemensSCALANCE X212-2
SiemensSCALANCE X212-2LD
SiemensSCALANCE X216
SiemensSCALANCE X224
SiemensSCALANCE X302-7 EEC (230V, coated)
SiemensSCALANCE X302-7 EEC (230V)
SiemensSCALANCE X302-7 EEC (24V, coated)
SiemensSCALANCE X302-7 EEC (24V)
SiemensSCALANCE X302-7 EEC (2x 230V, coated)
SiemensSCALANCE X302-7 EEC (2x 230V)
SiemensSCALANCE X302-7 EEC (2x 24V, coated)
SiemensSCALANCE X302-7 EEC (2x 24V)
SiemensSCALANCE X304-2FE
SiemensSCALANCE X306-1LD FE
SiemensSCALANCE X307-2 EEC (230V, coated)
SiemensSCALANCE X307-2 EEC (230V)
SiemensSCALANCE X307-2 EEC (24V, coated)
SiemensSCALANCE X307-2 EEC (24V)
SiemensSCALANCE X307-2 EEC (2x 230V, coated)
SiemensSCALANCE X307-2 EEC (2x 230V)
SiemensSCALANCE X307-2 EEC (2x 24V, coated)
SiemensSCALANCE X307-2 EEC (2x 24V)
SiemensSCALANCE X307-3
SiemensSCALANCE X307-3
SiemensSCALANCE X307-3LD
SiemensSCALANCE X307-3LD
SiemensSCALANCE X308-2
SiemensSCALANCE X308-2
SiemensSCALANCE X308-2LD
SiemensSCALANCE X308-2LD
SiemensSCALANCE X308-2LH
SiemensSCALANCE X308-2LH
SiemensSCALANCE X308-2LH+
SiemensSCALANCE X308-2LH+
SiemensSCALANCE X308-2M
SiemensSCALANCE X308-2M
SiemensSCALANCE X308-2M PoE
SiemensSCALANCE X308-2M PoE
SiemensSCALANCE X308-2M TS
SiemensSCALANCE X308-2M TS
SiemensSCALANCE X310
SiemensSCALANCE X310
SiemensSCALANCE X310FE
SiemensSCALANCE X310FE
SiemensSCALANCE X320-1 FE
SiemensSCALANCE X320-1-2LD FE
SiemensSCALANCE X408-2
SiemensSCALANCE XF201-3P IRT
SiemensSCALANCE XF202-2P IRT
SiemensSCALANCE XF204
SiemensSCALANCE XF204-2
SiemensSCALANCE XF204-2BA IRT
SiemensSCALANCE XF204IRT
SiemensSCALANCE XF206-1
SiemensSCALANCE XF208
SiemensSCALANCE XR324-12M (230V, ports on front)
SiemensSCALANCE XR324-12M (230V, ports on front)
SiemensSCALANCE XR324-12M (230V, ports on rear)
SiemensSCALANCE XR324-12M (230V, ports on rear)
SiemensSCALANCE XR324-12M (24V, ports on front)
SiemensSCALANCE XR324-12M (24V, ports on front)
SiemensSCALANCE XR324-12M (24V, ports on rear)
SiemensSCALANCE XR324-12M (24V, ports on rear)
SiemensSCALANCE XR324-12M TS (24V)
SiemensSCALANCE XR324-12M TS (24V)
SiemensSCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)
SiemensSCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)
SiemensSCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)
SiemensSCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)
SiemensSCALANCE XR324-4M EEC (24V, ports on front)
SiemensSCALANCE XR324-4M EEC (24V, ports on front)
SiemensSCALANCE XR324-4M EEC (24V, ports on rear)
SiemensSCALANCE XR324-4M EEC (24V, ports on rear)
SiemensSCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)
SiemensSCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)
SiemensSCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)
SiemensSCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)
SiemensSCALANCE XR324-4M EEC (2x 24V, ports on front)
SiemensSCALANCE XR324-4M EEC (2x 24V, ports on front)
SiemensSCALANCE XR324-4M EEC (2x 24V, ports on rear)
SiemensSCALANCE XR324-4M EEC (2x 24V, ports on rear)
SiemensSCALANCE XR324-4M PoE (230V, ports on front)
SiemensSCALANCE XR324-4M PoE (230V, ports on rear)
SiemensSCALANCE XR324-4M PoE (24V, ports on front)
SiemensSCALANCE XR324-4M PoE (24V, ports on rear)
SiemensSCALANCE XR324-4M PoE TS (24V, ports on front)
SiemensSIMATIC CP 343-1 Advanced
SiemensSIMATIC CP 442-1 RNA
SiemensSIMATIC CP 443-1
SiemensSIMATIC CP 443-1
SiemensSIMATIC CP 443-1 Advanced
SiemensSIMATIC CP 443-1 RNA
SiemensSIMATIC RF180C
SiemensSIMATIC RF182C
SiemensSIPLUS NET CP 343-1 Advanced
SiemensSIPLUS NET CP 443-1
SiemensSIPLUS NET CP 443-1 Advanced
SiemensSIPLUS NET SCALANCE X308-2
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T02:16:46.705Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-102233.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X200-4P IRT",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.5.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X201-3P IRT",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.5.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X201-3P IRT PRO",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.5.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X202-2IRT",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.5.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X202-2P IRT",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.5.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X202-2P IRT PRO",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.5.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X204-2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.2.5"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X204-2FM",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.2.5"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X204-2LD",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.2.5"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X204-2LD TS",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.2.5"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X204-2TS",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.2.5"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X204IRT",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.5.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X204IRT PRO",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.5.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X206-1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.2.5"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X206-1LD",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.2.5"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X208",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.2.5"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X208PRO",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.2.5"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X212-2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.2.5"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X212-2LD",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.2.5"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X216",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.2.5"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X224",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.2.5"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X302-7 EEC (230V, coated)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X302-7 EEC (230V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X302-7 EEC (24V, coated)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X302-7 EEC (24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X302-7 EEC (2x 230V, coated)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X302-7 EEC (2x 230V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X302-7 EEC (2x 24V, coated)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X302-7 EEC (2x 24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X304-2FE",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X306-1LD FE",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X307-2 EEC (230V, coated)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X307-2 EEC (230V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X307-2 EEC (24V, coated)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X307-2 EEC (24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X307-2 EEC (2x 230V, coated)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X307-2 EEC (2x 230V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X307-2 EEC (2x 24V, coated)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X307-2 EEC (2x 24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X307-3",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X307-3",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X307-3LD",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X307-3LD",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X308-2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X308-2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X308-2LD",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X308-2LD",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X308-2LH",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X308-2LH",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X308-2LH+",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X308-2LH+",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X308-2M",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X308-2M",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X308-2M PoE",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X308-2M PoE",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X308-2M TS",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X308-2M TS",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X310",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X310",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X310FE",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X310FE",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X320-1 FE",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X320-1-2LD FE",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X408-2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XF201-3P IRT",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.5.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XF202-2P IRT",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.5.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XF204",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.2.5"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XF204-2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.2.5"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XF204-2BA IRT",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.5.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XF204IRT",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.5.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XF206-1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.2.5"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XF208",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.2.5"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-12M (230V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-12M (230V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-12M (230V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-12M (230V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-12M (24V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-12M (24V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-12M (24V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-12M (24V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-12M TS (24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-12M TS (24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-4M EEC (24V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-4M EEC (24V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-4M EEC (24V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-4M EEC (24V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-4M EEC (2x 24V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-4M EEC (2x 24V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-4M EEC (2x 24V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-4M EEC (2x 24V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-4M PoE (230V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-4M PoE (230V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-4M PoE (24V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-4M PoE (24V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR324-4M PoE TS (24V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 343-1 Advanced",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 442-1 RNA",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V1.5.18"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 443-1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 443-1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 443-1 Advanced",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 443-1 RNA",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V1.5.18"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC RF180C",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC RF182C",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS NET CP 343-1 Advanced",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS NET CP 443-1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS NET CP 443-1 Advanced",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS NET SCALANCE X308-2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in SCALANCE X200-4P IRT, SCALANCE X201-3P IRT, SCALANCE X201-3P IRT PRO, SCALANCE X202-2IRT, SCALANCE X202-2P IRT, SCALANCE X202-2P IRT PRO, SCALANCE X204-2, SCALANCE X204-2FM, SCALANCE X204-2LD, SCALANCE X204-2LD TS, SCALANCE X204-2TS, SCALANCE X204IRT, SCALANCE X204IRT PRO, SCALANCE X206-1, SCALANCE X206-1LD, SCALANCE X208, SCALANCE X208PRO, SCALANCE X212-2, SCALANCE X212-2LD, SCALANCE X216, SCALANCE X224, SCALANCE X302-7 EEC (230V, coated), SCALANCE X302-7 EEC (230V), SCALANCE X302-7 EEC (24V, coated), SCALANCE X302-7 EEC (24V), SCALANCE X302-7 EEC (2x 230V, coated), SCALANCE X302-7 EEC (2x 230V), SCALANCE X302-7 EEC (2x 24V, coated), SCALANCE X302-7 EEC (2x 24V), SCALANCE X304-2FE, SCALANCE X306-1LD FE, SCALANCE X307-2 EEC (230V, coated), SCALANCE X307-2 EEC (230V), SCALANCE X307-2 EEC (24V, coated), SCALANCE X307-2 EEC (24V), SCALANCE X307-2 EEC (2x 230V, coated), SCALANCE X307-2 EEC (2x 230V), SCALANCE X307-2 EEC (2x 24V, coated), SCALANCE X307-2 EEC (2x 24V), SCALANCE X307-3, SCALANCE X307-3, SCALANCE X307-3LD, SCALANCE X307-3LD, SCALANCE X308-2, SCALANCE X308-2, SCALANCE X308-2LD, SCALANCE X308-2LD, SCALANCE X308-2LH, SCALANCE X308-2LH, SCALANCE X308-2LH+, SCALANCE X308-2LH+, SCALANCE X308-2M, SCALANCE X308-2M, SCALANCE X308-2M PoE, SCALANCE X308-2M PoE, SCALANCE X308-2M TS, SCALANCE X308-2M TS, SCALANCE X310, SCALANCE X310, SCALANCE X310FE, SCALANCE X310FE, SCALANCE X320-1 FE, SCALANCE X320-1-2LD FE, SCALANCE X408-2, SCALANCE XF201-3P IRT, SCALANCE XF202-2P IRT, SCALANCE XF204, SCALANCE XF204-2, SCALANCE XF204-2BA IRT, SCALANCE XF204IRT, SCALANCE XF206-1, SCALANCE XF208, SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M TS (24V), SCALANCE XR324-12M TS (24V), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M PoE (230V, ports on front), SCALANCE XR324-4M PoE (230V, ports on rear), SCALANCE XR324-4M PoE (24V, ports on front), SCALANCE XR324-4M PoE (24V, ports on rear), SCALANCE XR324-4M PoE TS (24V, ports on front), SIMATIC CP 343-1 Advanced, SIMATIC CP 442-1 RNA, SIMATIC CP 443-1, SIMATIC CP 443-1, SIMATIC CP 443-1 Advanced, SIMATIC CP 443-1 RNA, SIMATIC RF180C, SIMATIC RF182C, SIPLUS NET CP 343-1 Advanced, SIPLUS NET CP 443-1, SIPLUS NET CP 443-1 Advanced, SIPLUS NET SCALANCE X308-2. The VxWorks-based Profinet TCP Stack can be forced to make very expensive calls for every incoming packet which can lead to a denial of service."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:U/RC:C",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-400",
              "description": "CWE-400: Uncontrolled Resource Consumption",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-04-11T09:01:51.207Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-102233.pdf"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2019-19301",
    "datePublished": "2020-04-14T19:50:54",
    "dateReserved": "2019-11-26T00:00:00",
    "dateUpdated": "2024-08-05T02:16:46.705Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2022-26380
Vulnerability from cvelistv5
Published
2022-04-12 09:07
Modified
2024-08-03 05:03
Severity
Summary
A vulnerability has been identified in SCALANCE X302-7 EEC (230V), SCALANCE X302-7 EEC (230V, coated), SCALANCE X302-7 EEC (24V), SCALANCE X302-7 EEC (24V, coated), SCALANCE X302-7 EEC (2x 230V), SCALANCE X302-7 EEC (2x 230V, coated), SCALANCE X302-7 EEC (2x 24V), SCALANCE X302-7 EEC (2x 24V, coated), SCALANCE X304-2FE, SCALANCE X306-1LD FE, SCALANCE X307-2 EEC (230V), SCALANCE X307-2 EEC (230V, coated), SCALANCE X307-2 EEC (24V), SCALANCE X307-2 EEC (24V, coated), SCALANCE X307-2 EEC (2x 230V), SCALANCE X307-2 EEC (2x 230V, coated), SCALANCE X307-2 EEC (2x 24V), SCALANCE X307-2 EEC (2x 24V, coated), SCALANCE X307-3, SCALANCE X307-3, SCALANCE X307-3LD, SCALANCE X307-3LD, SCALANCE X308-2, SCALANCE X308-2, SCALANCE X308-2LD, SCALANCE X308-2LD, SCALANCE X308-2LH, SCALANCE X308-2LH, SCALANCE X308-2LH+, SCALANCE X308-2LH+, SCALANCE X308-2M, SCALANCE X308-2M, SCALANCE X308-2M PoE, SCALANCE X308-2M PoE, SCALANCE X308-2M TS, SCALANCE X308-2M TS, SCALANCE X310, SCALANCE X310, SCALANCE X310FE, SCALANCE X310FE, SCALANCE X320-1 FE, SCALANCE X320-1-2LD FE, SCALANCE X408-2, SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M TS (24V), SCALANCE XR324-12M TS (24V), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M PoE (230V, ports on front), SCALANCE XR324-4M PoE (230V, ports on rear), SCALANCE XR324-4M PoE (24V, ports on front), SCALANCE XR324-4M PoE (24V, ports on rear), SCALANCE XR324-4M PoE TS (24V, ports on front), SIPLUS NET SCALANCE X308-2. Affected devices do not properly validate if a certain SNMP key exists. An attacker could use this to trigger a reboot of an affected device by requesting specific SNMP information from the device.
Impacted products
VendorProduct
SiemensSCALANCE X302-7 EEC (230V)
SiemensSCALANCE X302-7 EEC (230V, coated)
SiemensSCALANCE X302-7 EEC (24V)
SiemensSCALANCE X302-7 EEC (24V, coated)
SiemensSCALANCE X302-7 EEC (2x 230V)
SiemensSCALANCE X302-7 EEC (2x 230V, coated)
SiemensSCALANCE X302-7 EEC (2x 24V)
SiemensSCALANCE X302-7 EEC (2x 24V, coated)
SiemensSCALANCE X304-2FE
SiemensSCALANCE X306-1LD FE
SiemensSCALANCE X307-2 EEC (230V)
SiemensSCALANCE X307-2 EEC (230V, coated)
SiemensSCALANCE X307-2 EEC (24V)
SiemensSCALANCE X307-2 EEC (24V, coated)
SiemensSCALANCE X307-2 EEC (2x 230V)
SiemensSCALANCE X307-2 EEC (2x 230V, coated)
SiemensSCALANCE X307-2 EEC (2x 24V)
SiemensSCALANCE X307-2 EEC (2x 24V, coated)
SiemensSCALANCE X307-3
SiemensSCALANCE X307-3
SiemensSCALANCE X307-3LD
SiemensSCALANCE X307-3LD
SiemensSCALANCE X308-2
SiemensSCALANCE X308-2
SiemensSCALANCE X308-2LD
SiemensSCALANCE X308-2LD
SiemensSCALANCE X308-2LH
SiemensSCALANCE X308-2LH
SiemensSCALANCE X308-2LH+
SiemensSCALANCE X308-2LH+
SiemensSCALANCE X308-2M
SiemensSCALANCE X308-2M
SiemensSCALANCE X308-2M PoE
SiemensSCALANCE X308-2M PoE
SiemensSCALANCE X308-2M TS
SiemensSCALANCE X308-2M TS
SiemensSCALANCE X310
SiemensSCALANCE X310
SiemensSCALANCE X310FE
SiemensSCALANCE X310FE
SiemensSCALANCE X320-1 FE
SiemensSCALANCE X320-1-2LD FE
SiemensSCALANCE X408-2
SiemensSCALANCE XR324-12M (230V, ports on front)
SiemensSCALANCE XR324-12M (230V, ports on front)
SiemensSCALANCE XR324-12M (230V, ports on rear)
SiemensSCALANCE XR324-12M (230V, ports on rear)
SiemensSCALANCE XR324-12M (24V, ports on front)
SiemensSCALANCE XR324-12M (24V, ports on front)
SiemensSCALANCE XR324-12M (24V, ports on rear)
SiemensSCALANCE XR324-12M (24V, ports on rear)
SiemensSCALANCE XR324-12M TS (24V)
SiemensSCALANCE XR324-12M TS (24V)
SiemensSCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)
SiemensSCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)
SiemensSCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)
SiemensSCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)
SiemensSCALANCE XR324-4M EEC (24V, ports on front)
SiemensSCALANCE XR324-4M EEC (24V, ports on front)
SiemensSCALANCE XR324-4M EEC (24V, ports on rear)
SiemensSCALANCE XR324-4M EEC (24V, ports on rear)
SiemensSCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)
SiemensSCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)
SiemensSCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)
SiemensSCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)
SiemensSCALANCE XR324-4M EEC (2x 24V, ports on front)
SiemensSCALANCE XR324-4M EEC (2x 24V, ports on front)
SiemensSCALANCE XR324-4M EEC (2x 24V, ports on rear)
SiemensSCALANCE XR324-4M EEC (2x 24V, ports on rear)
SiemensSCALANCE XR324-4M PoE (230V, ports on front)
SiemensSCALANCE XR324-4M PoE (230V, ports on rear)
SiemensSCALANCE XR324-4M PoE (24V, ports on front)
SiemensSCALANCE XR324-4M PoE (24V, ports on rear)
SiemensSCALANCE XR324-4M PoE TS (24V, ports on front)
SiemensSIPLUS NET SCALANCE X308-2
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T05:03:32.784Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-836527.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "SCALANCE X302-7 EEC (230V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X302-7 EEC (230V, coated)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X302-7 EEC (24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X302-7 EEC (24V, coated)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X302-7 EEC (2x 230V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X302-7 EEC (2x 230V, coated)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X302-7 EEC (2x 24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X302-7 EEC (2x 24V, coated)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X304-2FE",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X306-1LD FE",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X307-2 EEC (230V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X307-2 EEC (230V, coated)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X307-2 EEC (24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X307-2 EEC (24V, coated)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X307-2 EEC (2x 230V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X307-2 EEC (2x 230V, coated)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X307-2 EEC (2x 24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X307-2 EEC (2x 24V, coated)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X307-3",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X307-3",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X307-3LD",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X307-3LD",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2LD",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2LD",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2LH",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2LH",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2LH+",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2LH+",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2M",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2M",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2M PoE",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2M PoE",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2M TS",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2M TS",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X310",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X310",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X310FE",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X310FE",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X320-1 FE",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X320-1-2LD FE",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X408-2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-12M (230V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-12M (230V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-12M (230V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-12M (230V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-12M (24V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-12M (24V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-12M (24V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-12M (24V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-12M TS (24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-12M TS (24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (24V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (24V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (24V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (24V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (2x 24V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (2x 24V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (2x 24V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (2x 24V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M PoE (230V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M PoE (230V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M PoE (24V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M PoE (24V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M PoE TS (24V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SIPLUS NET SCALANCE X308-2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in SCALANCE X302-7 EEC (230V), SCALANCE X302-7 EEC (230V, coated), SCALANCE X302-7 EEC (24V), SCALANCE X302-7 EEC (24V, coated), SCALANCE X302-7 EEC (2x 230V), SCALANCE X302-7 EEC (2x 230V, coated), SCALANCE X302-7 EEC (2x 24V), SCALANCE X302-7 EEC (2x 24V, coated), SCALANCE X304-2FE, SCALANCE X306-1LD FE, SCALANCE X307-2 EEC (230V), SCALANCE X307-2 EEC (230V, coated), SCALANCE X307-2 EEC (24V), SCALANCE X307-2 EEC (24V, coated), SCALANCE X307-2 EEC (2x 230V), SCALANCE X307-2 EEC (2x 230V, coated), SCALANCE X307-2 EEC (2x 24V), SCALANCE X307-2 EEC (2x 24V, coated), SCALANCE X307-3, SCALANCE X307-3, SCALANCE X307-3LD, SCALANCE X307-3LD, SCALANCE X308-2, SCALANCE X308-2, SCALANCE X308-2LD, SCALANCE X308-2LD, SCALANCE X308-2LH, SCALANCE X308-2LH, SCALANCE X308-2LH+, SCALANCE X308-2LH+, SCALANCE X308-2M, SCALANCE X308-2M, SCALANCE X308-2M PoE, SCALANCE X308-2M PoE, SCALANCE X308-2M TS, SCALANCE X308-2M TS, SCALANCE X310, SCALANCE X310, SCALANCE X310FE, SCALANCE X310FE, SCALANCE X320-1 FE, SCALANCE X320-1-2LD FE, SCALANCE X408-2, SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M TS (24V), SCALANCE XR324-12M TS (24V), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M PoE (230V, ports on front), SCALANCE XR324-4M PoE (230V, ports on rear), SCALANCE XR324-4M PoE (24V, ports on front), SCALANCE XR324-4M PoE (24V, ports on rear), SCALANCE XR324-4M PoE TS (24V, ports on front), SIPLUS NET SCALANCE X308-2. Affected devices do not properly validate if a certain SNMP key exists. An attacker could use this to trigger a reboot of an affected device by requesting specific SNMP information from the device."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-125",
              "description": "CWE-125: Out-of-bounds Read",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-04-12T09:07:57",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-836527.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2022-26380",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "SCALANCE X302-7 EEC (230V)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X302-7 EEC (230V, coated)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X302-7 EEC (24V)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X302-7 EEC (24V, coated)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X302-7 EEC (2x 230V)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X302-7 EEC (2x 230V, coated)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X302-7 EEC (2x 24V)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X302-7 EEC (2x 24V, coated)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X304-2FE",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X306-1LD FE",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X307-2 EEC (230V)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X307-2 EEC (230V, coated)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X307-2 EEC (24V)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X307-2 EEC (24V, coated)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X307-2 EEC (2x 230V)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X307-2 EEC (2x 230V, coated)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X307-2 EEC (2x 24V)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X307-2 EEC (2x 24V, coated)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X307-3",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X307-3",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X307-3LD",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X307-3LD",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2LD",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2LD",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2LH",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2LH",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2LH+",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2LH+",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2M",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2M",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2M PoE",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2M PoE",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2M TS",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2M TS",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X310",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X310",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X310FE",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X310FE",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X320-1 FE",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X320-1-2LD FE",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X408-2",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-12M (230V, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-12M (230V, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-12M (230V, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-12M (230V, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-12M (24V, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-12M (24V, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-12M (24V, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-12M (24V, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-12M TS (24V)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-12M TS (24V)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (24V, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (24V, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (24V, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (24V, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (2x 24V, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (2x 24V, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (2x 24V, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (2x 24V, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M PoE (230V, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M PoE (230V, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M PoE (24V, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M PoE (24V, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M PoE TS (24V, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIPLUS NET SCALANCE X308-2",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in SCALANCE X302-7 EEC (230V), SCALANCE X302-7 EEC (230V, coated), SCALANCE X302-7 EEC (24V), SCALANCE X302-7 EEC (24V, coated), SCALANCE X302-7 EEC (2x 230V), SCALANCE X302-7 EEC (2x 230V, coated), SCALANCE X302-7 EEC (2x 24V), SCALANCE X302-7 EEC (2x 24V, coated), SCALANCE X304-2FE, SCALANCE X306-1LD FE, SCALANCE X307-2 EEC (230V), SCALANCE X307-2 EEC (230V, coated), SCALANCE X307-2 EEC (24V), SCALANCE X307-2 EEC (24V, coated), SCALANCE X307-2 EEC (2x 230V), SCALANCE X307-2 EEC (2x 230V, coated), SCALANCE X307-2 EEC (2x 24V), SCALANCE X307-2 EEC (2x 24V, coated), SCALANCE X307-3, SCALANCE X307-3, SCALANCE X307-3LD, SCALANCE X307-3LD, SCALANCE X308-2, SCALANCE X308-2, SCALANCE X308-2LD, SCALANCE X308-2LD, SCALANCE X308-2LH, SCALANCE X308-2LH, SCALANCE X308-2LH+, SCALANCE X308-2LH+, SCALANCE X308-2M, SCALANCE X308-2M, SCALANCE X308-2M PoE, SCALANCE X308-2M PoE, SCALANCE X308-2M TS, SCALANCE X308-2M TS, SCALANCE X310, SCALANCE X310, SCALANCE X310FE, SCALANCE X310FE, SCALANCE X320-1 FE, SCALANCE X320-1-2LD FE, SCALANCE X408-2, SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M TS (24V), SCALANCE XR324-12M TS (24V), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M PoE (230V, ports on front), SCALANCE XR324-4M PoE (230V, ports on rear), SCALANCE XR324-4M PoE (24V, ports on front), SCALANCE XR324-4M PoE (24V, ports on rear), SCALANCE XR324-4M PoE TS (24V, ports on front), SIPLUS NET SCALANCE X308-2. Affected devices do not properly validate if a certain SNMP key exists. An attacker could use this to trigger a reboot of an affected device by requesting specific SNMP information from the device."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-125: Out-of-bounds Read"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-836527.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-836527.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2022-26380",
    "datePublished": "2022-04-12T09:07:57",
    "dateReserved": "2022-03-03T00:00:00",
    "dateUpdated": "2024-08-03T05:03:32.784Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2022-25751
Vulnerability from cvelistv5
Published
2022-04-12 09:07
Modified
2024-08-03 04:49
Severity
Summary
A vulnerability has been identified in SCALANCE X302-7 EEC (230V), SCALANCE X302-7 EEC (230V, coated), SCALANCE X302-7 EEC (24V), SCALANCE X302-7 EEC (24V, coated), SCALANCE X302-7 EEC (2x 230V), SCALANCE X302-7 EEC (2x 230V, coated), SCALANCE X302-7 EEC (2x 24V), SCALANCE X302-7 EEC (2x 24V, coated), SCALANCE X304-2FE, SCALANCE X306-1LD FE, SCALANCE X307-2 EEC (230V), SCALANCE X307-2 EEC (230V, coated), SCALANCE X307-2 EEC (24V), SCALANCE X307-2 EEC (24V, coated), SCALANCE X307-2 EEC (2x 230V), SCALANCE X307-2 EEC (2x 230V, coated), SCALANCE X307-2 EEC (2x 24V), SCALANCE X307-2 EEC (2x 24V, coated), SCALANCE X307-3, SCALANCE X307-3, SCALANCE X307-3LD, SCALANCE X307-3LD, SCALANCE X308-2, SCALANCE X308-2, SCALANCE X308-2LD, SCALANCE X308-2LD, SCALANCE X308-2LH, SCALANCE X308-2LH, SCALANCE X308-2LH+, SCALANCE X308-2LH+, SCALANCE X308-2M, SCALANCE X308-2M, SCALANCE X308-2M PoE, SCALANCE X308-2M PoE, SCALANCE X308-2M TS, SCALANCE X308-2M TS, SCALANCE X310, SCALANCE X310, SCALANCE X310FE, SCALANCE X310FE, SCALANCE X320-1 FE, SCALANCE X320-1-2LD FE, SCALANCE X408-2, SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M TS (24V), SCALANCE XR324-12M TS (24V), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M PoE (230V, ports on front), SCALANCE XR324-4M PoE (230V, ports on rear), SCALANCE XR324-4M PoE (24V, ports on front), SCALANCE XR324-4M PoE (24V, ports on rear), SCALANCE XR324-4M PoE TS (24V, ports on front), SIPLUS NET SCALANCE X308-2. Affected devices do not properly validate the HTTP headers of incoming requests. This could allow an unauthenticated remote attacker to crash affected devices.
Impacted products
VendorProduct
SiemensSCALANCE X302-7 EEC (230V)
SiemensSCALANCE X302-7 EEC (230V, coated)
SiemensSCALANCE X302-7 EEC (24V)
SiemensSCALANCE X302-7 EEC (24V, coated)
SiemensSCALANCE X302-7 EEC (2x 230V)
SiemensSCALANCE X302-7 EEC (2x 230V, coated)
SiemensSCALANCE X302-7 EEC (2x 24V)
SiemensSCALANCE X302-7 EEC (2x 24V, coated)
SiemensSCALANCE X304-2FE
SiemensSCALANCE X306-1LD FE
SiemensSCALANCE X307-2 EEC (230V)
SiemensSCALANCE X307-2 EEC (230V, coated)
SiemensSCALANCE X307-2 EEC (24V)
SiemensSCALANCE X307-2 EEC (24V, coated)
SiemensSCALANCE X307-2 EEC (2x 230V)
SiemensSCALANCE X307-2 EEC (2x 230V, coated)
SiemensSCALANCE X307-2 EEC (2x 24V)
SiemensSCALANCE X307-2 EEC (2x 24V, coated)
SiemensSCALANCE X307-3
SiemensSCALANCE X307-3
SiemensSCALANCE X307-3LD
SiemensSCALANCE X307-3LD
SiemensSCALANCE X308-2
SiemensSCALANCE X308-2
SiemensSCALANCE X308-2LD
SiemensSCALANCE X308-2LD
SiemensSCALANCE X308-2LH
SiemensSCALANCE X308-2LH
SiemensSCALANCE X308-2LH+
SiemensSCALANCE X308-2LH+
SiemensSCALANCE X308-2M
SiemensSCALANCE X308-2M
SiemensSCALANCE X308-2M PoE
SiemensSCALANCE X308-2M PoE
SiemensSCALANCE X308-2M TS
SiemensSCALANCE X308-2M TS
SiemensSCALANCE X310
SiemensSCALANCE X310
SiemensSCALANCE X310FE
SiemensSCALANCE X310FE
SiemensSCALANCE X320-1 FE
SiemensSCALANCE X320-1-2LD FE
SiemensSCALANCE X408-2
SiemensSCALANCE XR324-12M (230V, ports on front)
SiemensSCALANCE XR324-12M (230V, ports on front)
SiemensSCALANCE XR324-12M (230V, ports on rear)
SiemensSCALANCE XR324-12M (230V, ports on rear)
SiemensSCALANCE XR324-12M (24V, ports on front)
SiemensSCALANCE XR324-12M (24V, ports on front)
SiemensSCALANCE XR324-12M (24V, ports on rear)
SiemensSCALANCE XR324-12M (24V, ports on rear)
SiemensSCALANCE XR324-12M TS (24V)
SiemensSCALANCE XR324-12M TS (24V)
SiemensSCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)
SiemensSCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)
SiemensSCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)
SiemensSCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)
SiemensSCALANCE XR324-4M EEC (24V, ports on front)
SiemensSCALANCE XR324-4M EEC (24V, ports on front)
SiemensSCALANCE XR324-4M EEC (24V, ports on rear)
SiemensSCALANCE XR324-4M EEC (24V, ports on rear)
SiemensSCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)
SiemensSCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)
SiemensSCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)
SiemensSCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)
SiemensSCALANCE XR324-4M EEC (2x 24V, ports on front)
SiemensSCALANCE XR324-4M EEC (2x 24V, ports on front)
SiemensSCALANCE XR324-4M EEC (2x 24V, ports on rear)
SiemensSCALANCE XR324-4M EEC (2x 24V, ports on rear)
SiemensSCALANCE XR324-4M PoE (230V, ports on front)
SiemensSCALANCE XR324-4M PoE (230V, ports on rear)
SiemensSCALANCE XR324-4M PoE (24V, ports on front)
SiemensSCALANCE XR324-4M PoE (24V, ports on rear)
SiemensSCALANCE XR324-4M PoE TS (24V, ports on front)
SiemensSIPLUS NET SCALANCE X308-2
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T04:49:43.841Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-836527.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "SCALANCE X302-7 EEC (230V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X302-7 EEC (230V, coated)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X302-7 EEC (24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X302-7 EEC (24V, coated)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X302-7 EEC (2x 230V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X302-7 EEC (2x 230V, coated)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X302-7 EEC (2x 24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X302-7 EEC (2x 24V, coated)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X304-2FE",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X306-1LD FE",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X307-2 EEC (230V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X307-2 EEC (230V, coated)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X307-2 EEC (24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X307-2 EEC (24V, coated)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X307-2 EEC (2x 230V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X307-2 EEC (2x 230V, coated)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X307-2 EEC (2x 24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X307-2 EEC (2x 24V, coated)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X307-3",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X307-3",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X307-3LD",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X307-3LD",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2LD",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2LD",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2LH",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2LH",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2LH+",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2LH+",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2M",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2M",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2M PoE",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2M PoE",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2M TS",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2M TS",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X310",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X310",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X310FE",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X310FE",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X320-1 FE",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X320-1-2LD FE",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X408-2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-12M (230V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-12M (230V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-12M (230V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-12M (230V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-12M (24V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-12M (24V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-12M (24V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-12M (24V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-12M TS (24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-12M TS (24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (24V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (24V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (24V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (24V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (2x 24V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (2x 24V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (2x 24V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (2x 24V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M PoE (230V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M PoE (230V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M PoE (24V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M PoE (24V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M PoE TS (24V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SIPLUS NET SCALANCE X308-2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in SCALANCE X302-7 EEC (230V), SCALANCE X302-7 EEC (230V, coated), SCALANCE X302-7 EEC (24V), SCALANCE X302-7 EEC (24V, coated), SCALANCE X302-7 EEC (2x 230V), SCALANCE X302-7 EEC (2x 230V, coated), SCALANCE X302-7 EEC (2x 24V), SCALANCE X302-7 EEC (2x 24V, coated), SCALANCE X304-2FE, SCALANCE X306-1LD FE, SCALANCE X307-2 EEC (230V), SCALANCE X307-2 EEC (230V, coated), SCALANCE X307-2 EEC (24V), SCALANCE X307-2 EEC (24V, coated), SCALANCE X307-2 EEC (2x 230V), SCALANCE X307-2 EEC (2x 230V, coated), SCALANCE X307-2 EEC (2x 24V), SCALANCE X307-2 EEC (2x 24V, coated), SCALANCE X307-3, SCALANCE X307-3, SCALANCE X307-3LD, SCALANCE X307-3LD, SCALANCE X308-2, SCALANCE X308-2, SCALANCE X308-2LD, SCALANCE X308-2LD, SCALANCE X308-2LH, SCALANCE X308-2LH, SCALANCE X308-2LH+, SCALANCE X308-2LH+, SCALANCE X308-2M, SCALANCE X308-2M, SCALANCE X308-2M PoE, SCALANCE X308-2M PoE, SCALANCE X308-2M TS, SCALANCE X308-2M TS, SCALANCE X310, SCALANCE X310, SCALANCE X310FE, SCALANCE X310FE, SCALANCE X320-1 FE, SCALANCE X320-1-2LD FE, SCALANCE X408-2, SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M TS (24V), SCALANCE XR324-12M TS (24V), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M PoE (230V, ports on front), SCALANCE XR324-4M PoE (230V, ports on rear), SCALANCE XR324-4M PoE (24V, ports on front), SCALANCE XR324-4M PoE (24V, ports on rear), SCALANCE XR324-4M PoE TS (24V, ports on front), SIPLUS NET SCALANCE X308-2. Affected devices do not properly validate the HTTP headers of incoming requests. This could allow an unauthenticated remote attacker to crash affected devices."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-20",
              "description": "CWE-20: Improper Input Validation",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-04-12T09:07:43",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-836527.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2022-25751",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "SCALANCE X302-7 EEC (230V)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X302-7 EEC (230V, coated)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X302-7 EEC (24V)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X302-7 EEC (24V, coated)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X302-7 EEC (2x 230V)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X302-7 EEC (2x 230V, coated)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X302-7 EEC (2x 24V)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X302-7 EEC (2x 24V, coated)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X304-2FE",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X306-1LD FE",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X307-2 EEC (230V)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X307-2 EEC (230V, coated)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X307-2 EEC (24V)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X307-2 EEC (24V, coated)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X307-2 EEC (2x 230V)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X307-2 EEC (2x 230V, coated)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X307-2 EEC (2x 24V)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X307-2 EEC (2x 24V, coated)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X307-3",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X307-3",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X307-3LD",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X307-3LD",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2LD",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2LD",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2LH",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2LH",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2LH+",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2LH+",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2M",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2M",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2M PoE",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2M PoE",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2M TS",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2M TS",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X310",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X310",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X310FE",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X310FE",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X320-1 FE",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X320-1-2LD FE",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X408-2",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-12M (230V, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-12M (230V, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-12M (230V, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-12M (230V, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-12M (24V, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-12M (24V, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-12M (24V, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-12M (24V, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-12M TS (24V)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-12M TS (24V)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (24V, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (24V, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (24V, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (24V, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (2x 24V, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (2x 24V, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (2x 24V, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (2x 24V, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M PoE (230V, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M PoE (230V, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M PoE (24V, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M PoE (24V, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M PoE TS (24V, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIPLUS NET SCALANCE X308-2",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in SCALANCE X302-7 EEC (230V), SCALANCE X302-7 EEC (230V, coated), SCALANCE X302-7 EEC (24V), SCALANCE X302-7 EEC (24V, coated), SCALANCE X302-7 EEC (2x 230V), SCALANCE X302-7 EEC (2x 230V, coated), SCALANCE X302-7 EEC (2x 24V), SCALANCE X302-7 EEC (2x 24V, coated), SCALANCE X304-2FE, SCALANCE X306-1LD FE, SCALANCE X307-2 EEC (230V), SCALANCE X307-2 EEC (230V, coated), SCALANCE X307-2 EEC (24V), SCALANCE X307-2 EEC (24V, coated), SCALANCE X307-2 EEC (2x 230V), SCALANCE X307-2 EEC (2x 230V, coated), SCALANCE X307-2 EEC (2x 24V), SCALANCE X307-2 EEC (2x 24V, coated), SCALANCE X307-3, SCALANCE X307-3, SCALANCE X307-3LD, SCALANCE X307-3LD, SCALANCE X308-2, SCALANCE X308-2, SCALANCE X308-2LD, SCALANCE X308-2LD, SCALANCE X308-2LH, SCALANCE X308-2LH, SCALANCE X308-2LH+, SCALANCE X308-2LH+, SCALANCE X308-2M, SCALANCE X308-2M, SCALANCE X308-2M PoE, SCALANCE X308-2M PoE, SCALANCE X308-2M TS, SCALANCE X308-2M TS, SCALANCE X310, SCALANCE X310, SCALANCE X310FE, SCALANCE X310FE, SCALANCE X320-1 FE, SCALANCE X320-1-2LD FE, SCALANCE X408-2, SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M TS (24V), SCALANCE XR324-12M TS (24V), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M PoE (230V, ports on front), SCALANCE XR324-4M PoE (230V, ports on rear), SCALANCE XR324-4M PoE (24V, ports on front), SCALANCE XR324-4M PoE (24V, ports on rear), SCALANCE XR324-4M PoE TS (24V, ports on front), SIPLUS NET SCALANCE X308-2. Affected devices do not properly validate the HTTP headers of incoming requests. This could allow an unauthenticated remote attacker to crash affected devices."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-20: Improper Input Validation"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-836527.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-836527.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2022-25751",
    "datePublished": "2022-04-12T09:07:43",
    "dateReserved": "2022-02-22T00:00:00",
    "dateUpdated": "2024-08-03T04:49:43.841Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2022-25755
Vulnerability from cvelistv5
Published
2022-04-12 09:07
Modified
2024-08-03 04:49
Severity
Summary
A vulnerability has been identified in SCALANCE X302-7 EEC (230V), SCALANCE X302-7 EEC (230V, coated), SCALANCE X302-7 EEC (24V), SCALANCE X302-7 EEC (24V, coated), SCALANCE X302-7 EEC (2x 230V), SCALANCE X302-7 EEC (2x 230V, coated), SCALANCE X302-7 EEC (2x 24V), SCALANCE X302-7 EEC (2x 24V, coated), SCALANCE X304-2FE, SCALANCE X306-1LD FE, SCALANCE X307-2 EEC (230V), SCALANCE X307-2 EEC (230V, coated), SCALANCE X307-2 EEC (24V), SCALANCE X307-2 EEC (24V, coated), SCALANCE X307-2 EEC (2x 230V), SCALANCE X307-2 EEC (2x 230V, coated), SCALANCE X307-2 EEC (2x 24V), SCALANCE X307-2 EEC (2x 24V, coated), SCALANCE X307-3, SCALANCE X307-3, SCALANCE X307-3LD, SCALANCE X307-3LD, SCALANCE X308-2, SCALANCE X308-2, SCALANCE X308-2LD, SCALANCE X308-2LD, SCALANCE X308-2LH, SCALANCE X308-2LH, SCALANCE X308-2LH+, SCALANCE X308-2LH+, SCALANCE X308-2M, SCALANCE X308-2M, SCALANCE X308-2M PoE, SCALANCE X308-2M PoE, SCALANCE X308-2M TS, SCALANCE X308-2M TS, SCALANCE X310, SCALANCE X310, SCALANCE X310FE, SCALANCE X310FE, SCALANCE X320-1 FE, SCALANCE X320-1-2LD FE, SCALANCE X408-2, SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M TS (24V), SCALANCE XR324-12M TS (24V), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M PoE (230V, ports on front), SCALANCE XR324-4M PoE (230V, ports on rear), SCALANCE XR324-4M PoE (24V, ports on front), SCALANCE XR324-4M PoE (24V, ports on rear), SCALANCE XR324-4M PoE TS (24V, ports on front), SIPLUS NET SCALANCE X308-2. The webserver of an affected device is missing specific security headers. This could allow an remote attacker to extract confidential session information under certain circumstances.
Impacted products
VendorProduct
SiemensSCALANCE X302-7 EEC (230V)
SiemensSCALANCE X302-7 EEC (230V, coated)
SiemensSCALANCE X302-7 EEC (24V)
SiemensSCALANCE X302-7 EEC (24V, coated)
SiemensSCALANCE X302-7 EEC (2x 230V)
SiemensSCALANCE X302-7 EEC (2x 230V, coated)
SiemensSCALANCE X302-7 EEC (2x 24V)
SiemensSCALANCE X302-7 EEC (2x 24V, coated)
SiemensSCALANCE X304-2FE
SiemensSCALANCE X306-1LD FE
SiemensSCALANCE X307-2 EEC (230V)
SiemensSCALANCE X307-2 EEC (230V, coated)
SiemensSCALANCE X307-2 EEC (24V)
SiemensSCALANCE X307-2 EEC (24V, coated)
SiemensSCALANCE X307-2 EEC (2x 230V)
SiemensSCALANCE X307-2 EEC (2x 230V, coated)
SiemensSCALANCE X307-2 EEC (2x 24V)
SiemensSCALANCE X307-2 EEC (2x 24V, coated)
SiemensSCALANCE X307-3
SiemensSCALANCE X307-3
SiemensSCALANCE X307-3LD
SiemensSCALANCE X307-3LD
SiemensSCALANCE X308-2
SiemensSCALANCE X308-2
SiemensSCALANCE X308-2LD
SiemensSCALANCE X308-2LD
SiemensSCALANCE X308-2LH
SiemensSCALANCE X308-2LH
SiemensSCALANCE X308-2LH+
SiemensSCALANCE X308-2LH+
SiemensSCALANCE X308-2M
SiemensSCALANCE X308-2M
SiemensSCALANCE X308-2M PoE
SiemensSCALANCE X308-2M PoE
SiemensSCALANCE X308-2M TS
SiemensSCALANCE X308-2M TS
SiemensSCALANCE X310
SiemensSCALANCE X310
SiemensSCALANCE X310FE
SiemensSCALANCE X310FE
SiemensSCALANCE X320-1 FE
SiemensSCALANCE X320-1-2LD FE
SiemensSCALANCE X408-2
SiemensSCALANCE XR324-12M (230V, ports on front)
SiemensSCALANCE XR324-12M (230V, ports on front)
SiemensSCALANCE XR324-12M (230V, ports on rear)
SiemensSCALANCE XR324-12M (230V, ports on rear)
SiemensSCALANCE XR324-12M (24V, ports on front)
SiemensSCALANCE XR324-12M (24V, ports on front)
SiemensSCALANCE XR324-12M (24V, ports on rear)
SiemensSCALANCE XR324-12M (24V, ports on rear)
SiemensSCALANCE XR324-12M TS (24V)
SiemensSCALANCE XR324-12M TS (24V)
SiemensSCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)
SiemensSCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)
SiemensSCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)
SiemensSCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)
SiemensSCALANCE XR324-4M EEC (24V, ports on front)
SiemensSCALANCE XR324-4M EEC (24V, ports on front)
SiemensSCALANCE XR324-4M EEC (24V, ports on rear)
SiemensSCALANCE XR324-4M EEC (24V, ports on rear)
SiemensSCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)
SiemensSCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)
SiemensSCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)
SiemensSCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)
SiemensSCALANCE XR324-4M EEC (2x 24V, ports on front)
SiemensSCALANCE XR324-4M EEC (2x 24V, ports on front)
SiemensSCALANCE XR324-4M EEC (2x 24V, ports on rear)
SiemensSCALANCE XR324-4M EEC (2x 24V, ports on rear)
SiemensSCALANCE XR324-4M PoE (230V, ports on front)
SiemensSCALANCE XR324-4M PoE (230V, ports on rear)
SiemensSCALANCE XR324-4M PoE (24V, ports on front)
SiemensSCALANCE XR324-4M PoE (24V, ports on rear)
SiemensSCALANCE XR324-4M PoE TS (24V, ports on front)
SiemensSIPLUS NET SCALANCE X308-2
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T04:49:43.216Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-836527.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "SCALANCE X302-7 EEC (230V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X302-7 EEC (230V, coated)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X302-7 EEC (24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X302-7 EEC (24V, coated)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X302-7 EEC (2x 230V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X302-7 EEC (2x 230V, coated)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X302-7 EEC (2x 24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X302-7 EEC (2x 24V, coated)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X304-2FE",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X306-1LD FE",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X307-2 EEC (230V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X307-2 EEC (230V, coated)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X307-2 EEC (24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X307-2 EEC (24V, coated)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X307-2 EEC (2x 230V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X307-2 EEC (2x 230V, coated)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X307-2 EEC (2x 24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X307-2 EEC (2x 24V, coated)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X307-3",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X307-3",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X307-3LD",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X307-3LD",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2LD",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2LD",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2LH",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2LH",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2LH+",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2LH+",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2M",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2M",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2M PoE",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2M PoE",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2M TS",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2M TS",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X310",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X310",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X310FE",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X310FE",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X320-1 FE",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X320-1-2LD FE",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X408-2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-12M (230V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-12M (230V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-12M (230V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-12M (230V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-12M (24V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-12M (24V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-12M (24V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-12M (24V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-12M TS (24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-12M TS (24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (24V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (24V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (24V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (24V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (2x 24V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (2x 24V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (2x 24V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (2x 24V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M PoE (230V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M PoE (230V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M PoE (24V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M PoE (24V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M PoE TS (24V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SIPLUS NET SCALANCE X308-2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in SCALANCE X302-7 EEC (230V), SCALANCE X302-7 EEC (230V, coated), SCALANCE X302-7 EEC (24V), SCALANCE X302-7 EEC (24V, coated), SCALANCE X302-7 EEC (2x 230V), SCALANCE X302-7 EEC (2x 230V, coated), SCALANCE X302-7 EEC (2x 24V), SCALANCE X302-7 EEC (2x 24V, coated), SCALANCE X304-2FE, SCALANCE X306-1LD FE, SCALANCE X307-2 EEC (230V), SCALANCE X307-2 EEC (230V, coated), SCALANCE X307-2 EEC (24V), SCALANCE X307-2 EEC (24V, coated), SCALANCE X307-2 EEC (2x 230V), SCALANCE X307-2 EEC (2x 230V, coated), SCALANCE X307-2 EEC (2x 24V), SCALANCE X307-2 EEC (2x 24V, coated), SCALANCE X307-3, SCALANCE X307-3, SCALANCE X307-3LD, SCALANCE X307-3LD, SCALANCE X308-2, SCALANCE X308-2, SCALANCE X308-2LD, SCALANCE X308-2LD, SCALANCE X308-2LH, SCALANCE X308-2LH, SCALANCE X308-2LH+, SCALANCE X308-2LH+, SCALANCE X308-2M, SCALANCE X308-2M, SCALANCE X308-2M PoE, SCALANCE X308-2M PoE, SCALANCE X308-2M TS, SCALANCE X308-2M TS, SCALANCE X310, SCALANCE X310, SCALANCE X310FE, SCALANCE X310FE, SCALANCE X320-1 FE, SCALANCE X320-1-2LD FE, SCALANCE X408-2, SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M TS (24V), SCALANCE XR324-12M TS (24V), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M PoE (230V, ports on front), SCALANCE XR324-4M PoE (230V, ports on rear), SCALANCE XR324-4M PoE (24V, ports on front), SCALANCE XR324-4M PoE (24V, ports on rear), SCALANCE XR324-4M PoE TS (24V, ports on front), SIPLUS NET SCALANCE X308-2. The webserver of an affected device is missing specific security headers. This could allow an remote attacker to extract confidential session information under certain circumstances."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-284",
              "description": "CWE-284: Improper Access Control",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-04-12T09:07:50",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-836527.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2022-25755",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "SCALANCE X302-7 EEC (230V)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X302-7 EEC (230V, coated)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X302-7 EEC (24V)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X302-7 EEC (24V, coated)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X302-7 EEC (2x 230V)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X302-7 EEC (2x 230V, coated)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X302-7 EEC (2x 24V)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X302-7 EEC (2x 24V, coated)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X304-2FE",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X306-1LD FE",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X307-2 EEC (230V)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X307-2 EEC (230V, coated)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X307-2 EEC (24V)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X307-2 EEC (24V, coated)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X307-2 EEC (2x 230V)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X307-2 EEC (2x 230V, coated)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X307-2 EEC (2x 24V)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X307-2 EEC (2x 24V, coated)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X307-3",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X307-3",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X307-3LD",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X307-3LD",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2LD",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2LD",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2LH",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2LH",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2LH+",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2LH+",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2M",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2M",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2M PoE",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2M PoE",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2M TS",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2M TS",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X310",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X310",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X310FE",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X310FE",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X320-1 FE",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X320-1-2LD FE",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X408-2",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-12M (230V, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-12M (230V, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-12M (230V, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-12M (230V, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-12M (24V, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-12M (24V, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-12M (24V, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-12M (24V, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-12M TS (24V)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-12M TS (24V)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (24V, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (24V, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (24V, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (24V, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (2x 24V, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (2x 24V, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (2x 24V, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (2x 24V, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M PoE (230V, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M PoE (230V, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M PoE (24V, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M PoE (24V, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M PoE TS (24V, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIPLUS NET SCALANCE X308-2",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in SCALANCE X302-7 EEC (230V), SCALANCE X302-7 EEC (230V, coated), SCALANCE X302-7 EEC (24V), SCALANCE X302-7 EEC (24V, coated), SCALANCE X302-7 EEC (2x 230V), SCALANCE X302-7 EEC (2x 230V, coated), SCALANCE X302-7 EEC (2x 24V), SCALANCE X302-7 EEC (2x 24V, coated), SCALANCE X304-2FE, SCALANCE X306-1LD FE, SCALANCE X307-2 EEC (230V), SCALANCE X307-2 EEC (230V, coated), SCALANCE X307-2 EEC (24V), SCALANCE X307-2 EEC (24V, coated), SCALANCE X307-2 EEC (2x 230V), SCALANCE X307-2 EEC (2x 230V, coated), SCALANCE X307-2 EEC (2x 24V), SCALANCE X307-2 EEC (2x 24V, coated), SCALANCE X307-3, SCALANCE X307-3, SCALANCE X307-3LD, SCALANCE X307-3LD, SCALANCE X308-2, SCALANCE X308-2, SCALANCE X308-2LD, SCALANCE X308-2LD, SCALANCE X308-2LH, SCALANCE X308-2LH, SCALANCE X308-2LH+, SCALANCE X308-2LH+, SCALANCE X308-2M, SCALANCE X308-2M, SCALANCE X308-2M PoE, SCALANCE X308-2M PoE, SCALANCE X308-2M TS, SCALANCE X308-2M TS, SCALANCE X310, SCALANCE X310, SCALANCE X310FE, SCALANCE X310FE, SCALANCE X320-1 FE, SCALANCE X320-1-2LD FE, SCALANCE X408-2, SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M TS (24V), SCALANCE XR324-12M TS (24V), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M PoE (230V, ports on front), SCALANCE XR324-4M PoE (230V, ports on rear), SCALANCE XR324-4M PoE (24V, ports on front), SCALANCE XR324-4M PoE (24V, ports on rear), SCALANCE XR324-4M PoE TS (24V, ports on front), SIPLUS NET SCALANCE X308-2. The webserver of an affected device is missing specific security headers. This could allow an remote attacker to extract confidential session information under certain circumstances."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-284: Improper Access Control"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-836527.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-836527.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2022-25755",
    "datePublished": "2022-04-12T09:07:50",
    "dateReserved": "2022-02-22T00:00:00",
    "dateUpdated": "2024-08-03T04:49:43.216Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2022-25754
Vulnerability from cvelistv5
Published
2022-04-12 09:07
Modified
2024-08-03 04:49
Severity
Summary
A vulnerability has been identified in SCALANCE X302-7 EEC (230V), SCALANCE X302-7 EEC (230V, coated), SCALANCE X302-7 EEC (24V), SCALANCE X302-7 EEC (24V, coated), SCALANCE X302-7 EEC (2x 230V), SCALANCE X302-7 EEC (2x 230V, coated), SCALANCE X302-7 EEC (2x 24V), SCALANCE X302-7 EEC (2x 24V, coated), SCALANCE X304-2FE, SCALANCE X306-1LD FE, SCALANCE X307-2 EEC (230V), SCALANCE X307-2 EEC (230V, coated), SCALANCE X307-2 EEC (24V), SCALANCE X307-2 EEC (24V, coated), SCALANCE X307-2 EEC (2x 230V), SCALANCE X307-2 EEC (2x 230V, coated), SCALANCE X307-2 EEC (2x 24V), SCALANCE X307-2 EEC (2x 24V, coated), SCALANCE X307-3, SCALANCE X307-3, SCALANCE X307-3LD, SCALANCE X307-3LD, SCALANCE X308-2, SCALANCE X308-2, SCALANCE X308-2LD, SCALANCE X308-2LD, SCALANCE X308-2LH, SCALANCE X308-2LH, SCALANCE X308-2LH+, SCALANCE X308-2LH+, SCALANCE X308-2M, SCALANCE X308-2M, SCALANCE X308-2M PoE, SCALANCE X308-2M PoE, SCALANCE X308-2M TS, SCALANCE X308-2M TS, SCALANCE X310, SCALANCE X310, SCALANCE X310FE, SCALANCE X310FE, SCALANCE X320-1 FE, SCALANCE X320-1-2LD FE, SCALANCE X408-2, SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M TS (24V), SCALANCE XR324-12M TS (24V), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M PoE (230V, ports on front), SCALANCE XR324-4M PoE (230V, ports on rear), SCALANCE XR324-4M PoE (24V, ports on front), SCALANCE XR324-4M PoE (24V, ports on rear), SCALANCE XR324-4M PoE TS (24V, ports on front), SIPLUS NET SCALANCE X308-2. The integrated web server of the affected device could allow remote attackers to perform actions with the permissions of a victim user, provided the victim user has an active session and is induced to trigger the malicious request.
Impacted products
VendorProduct
SiemensSCALANCE X302-7 EEC (230V)
SiemensSCALANCE X302-7 EEC (230V, coated)
SiemensSCALANCE X302-7 EEC (24V)
SiemensSCALANCE X302-7 EEC (24V, coated)
SiemensSCALANCE X302-7 EEC (2x 230V)
SiemensSCALANCE X302-7 EEC (2x 230V, coated)
SiemensSCALANCE X302-7 EEC (2x 24V)
SiemensSCALANCE X302-7 EEC (2x 24V, coated)
SiemensSCALANCE X304-2FE
SiemensSCALANCE X306-1LD FE
SiemensSCALANCE X307-2 EEC (230V)
SiemensSCALANCE X307-2 EEC (230V, coated)
SiemensSCALANCE X307-2 EEC (24V)
SiemensSCALANCE X307-2 EEC (24V, coated)
SiemensSCALANCE X307-2 EEC (2x 230V)
SiemensSCALANCE X307-2 EEC (2x 230V, coated)
SiemensSCALANCE X307-2 EEC (2x 24V)
SiemensSCALANCE X307-2 EEC (2x 24V, coated)
SiemensSCALANCE X307-3
SiemensSCALANCE X307-3
SiemensSCALANCE X307-3LD
SiemensSCALANCE X307-3LD
SiemensSCALANCE X308-2
SiemensSCALANCE X308-2
SiemensSCALANCE X308-2LD
SiemensSCALANCE X308-2LD
SiemensSCALANCE X308-2LH
SiemensSCALANCE X308-2LH
SiemensSCALANCE X308-2LH+
SiemensSCALANCE X308-2LH+
SiemensSCALANCE X308-2M
SiemensSCALANCE X308-2M
SiemensSCALANCE X308-2M PoE
SiemensSCALANCE X308-2M PoE
SiemensSCALANCE X308-2M TS
SiemensSCALANCE X308-2M TS
SiemensSCALANCE X310
SiemensSCALANCE X310
SiemensSCALANCE X310FE
SiemensSCALANCE X310FE
SiemensSCALANCE X320-1 FE
SiemensSCALANCE X320-1-2LD FE
SiemensSCALANCE X408-2
SiemensSCALANCE XR324-12M (230V, ports on front)
SiemensSCALANCE XR324-12M (230V, ports on front)
SiemensSCALANCE XR324-12M (230V, ports on rear)
SiemensSCALANCE XR324-12M (230V, ports on rear)
SiemensSCALANCE XR324-12M (24V, ports on front)
SiemensSCALANCE XR324-12M (24V, ports on front)
SiemensSCALANCE XR324-12M (24V, ports on rear)
SiemensSCALANCE XR324-12M (24V, ports on rear)
SiemensSCALANCE XR324-12M TS (24V)
SiemensSCALANCE XR324-12M TS (24V)
SiemensSCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)
SiemensSCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)
SiemensSCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)
SiemensSCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)
SiemensSCALANCE XR324-4M EEC (24V, ports on front)
SiemensSCALANCE XR324-4M EEC (24V, ports on front)
SiemensSCALANCE XR324-4M EEC (24V, ports on rear)
SiemensSCALANCE XR324-4M EEC (24V, ports on rear)
SiemensSCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)
SiemensSCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)
SiemensSCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)
SiemensSCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)
SiemensSCALANCE XR324-4M EEC (2x 24V, ports on front)
SiemensSCALANCE XR324-4M EEC (2x 24V, ports on front)
SiemensSCALANCE XR324-4M EEC (2x 24V, ports on rear)
SiemensSCALANCE XR324-4M EEC (2x 24V, ports on rear)
SiemensSCALANCE XR324-4M PoE (230V, ports on front)
SiemensSCALANCE XR324-4M PoE (230V, ports on rear)
SiemensSCALANCE XR324-4M PoE (24V, ports on front)
SiemensSCALANCE XR324-4M PoE (24V, ports on rear)
SiemensSCALANCE XR324-4M PoE TS (24V, ports on front)
SiemensSIPLUS NET SCALANCE X308-2
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T04:49:43.242Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-836527.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "SCALANCE X302-7 EEC (230V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X302-7 EEC (230V, coated)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X302-7 EEC (24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X302-7 EEC (24V, coated)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X302-7 EEC (2x 230V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X302-7 EEC (2x 230V, coated)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X302-7 EEC (2x 24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X302-7 EEC (2x 24V, coated)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X304-2FE",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X306-1LD FE",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X307-2 EEC (230V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X307-2 EEC (230V, coated)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X307-2 EEC (24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X307-2 EEC (24V, coated)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X307-2 EEC (2x 230V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X307-2 EEC (2x 230V, coated)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X307-2 EEC (2x 24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X307-2 EEC (2x 24V, coated)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X307-3",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X307-3",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X307-3LD",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X307-3LD",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2LD",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2LD",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2LH",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2LH",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2LH+",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2LH+",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2M",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2M",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2M PoE",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2M PoE",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2M TS",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2M TS",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X310",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X310",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X310FE",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X310FE",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X320-1 FE",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X320-1-2LD FE",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X408-2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-12M (230V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-12M (230V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-12M (230V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-12M (230V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-12M (24V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-12M (24V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-12M (24V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-12M (24V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-12M TS (24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-12M TS (24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (24V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (24V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (24V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (24V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (2x 24V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (2x 24V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (2x 24V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (2x 24V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M PoE (230V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M PoE (230V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M PoE (24V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M PoE (24V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M PoE TS (24V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SIPLUS NET SCALANCE X308-2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in SCALANCE X302-7 EEC (230V), SCALANCE X302-7 EEC (230V, coated), SCALANCE X302-7 EEC (24V), SCALANCE X302-7 EEC (24V, coated), SCALANCE X302-7 EEC (2x 230V), SCALANCE X302-7 EEC (2x 230V, coated), SCALANCE X302-7 EEC (2x 24V), SCALANCE X302-7 EEC (2x 24V, coated), SCALANCE X304-2FE, SCALANCE X306-1LD FE, SCALANCE X307-2 EEC (230V), SCALANCE X307-2 EEC (230V, coated), SCALANCE X307-2 EEC (24V), SCALANCE X307-2 EEC (24V, coated), SCALANCE X307-2 EEC (2x 230V), SCALANCE X307-2 EEC (2x 230V, coated), SCALANCE X307-2 EEC (2x 24V), SCALANCE X307-2 EEC (2x 24V, coated), SCALANCE X307-3, SCALANCE X307-3, SCALANCE X307-3LD, SCALANCE X307-3LD, SCALANCE X308-2, SCALANCE X308-2, SCALANCE X308-2LD, SCALANCE X308-2LD, SCALANCE X308-2LH, SCALANCE X308-2LH, SCALANCE X308-2LH+, SCALANCE X308-2LH+, SCALANCE X308-2M, SCALANCE X308-2M, SCALANCE X308-2M PoE, SCALANCE X308-2M PoE, SCALANCE X308-2M TS, SCALANCE X308-2M TS, SCALANCE X310, SCALANCE X310, SCALANCE X310FE, SCALANCE X310FE, SCALANCE X320-1 FE, SCALANCE X320-1-2LD FE, SCALANCE X408-2, SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M TS (24V), SCALANCE XR324-12M TS (24V), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M PoE (230V, ports on front), SCALANCE XR324-4M PoE (230V, ports on rear), SCALANCE XR324-4M PoE (24V, ports on front), SCALANCE XR324-4M PoE (24V, ports on rear), SCALANCE XR324-4M PoE TS (24V, ports on front), SIPLUS NET SCALANCE X308-2. The integrated web server of the affected device could allow remote attackers to perform actions with the permissions of a victim user, provided the victim user has an active session and is induced to trigger the malicious request."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-352",
              "description": "CWE-352: Cross-Site Request Forgery (CSRF)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-04-12T09:07:49",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-836527.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2022-25754",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "SCALANCE X302-7 EEC (230V)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X302-7 EEC (230V, coated)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X302-7 EEC (24V)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X302-7 EEC (24V, coated)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X302-7 EEC (2x 230V)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X302-7 EEC (2x 230V, coated)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X302-7 EEC (2x 24V)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X302-7 EEC (2x 24V, coated)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X304-2FE",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X306-1LD FE",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X307-2 EEC (230V)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X307-2 EEC (230V, coated)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X307-2 EEC (24V)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X307-2 EEC (24V, coated)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X307-2 EEC (2x 230V)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X307-2 EEC (2x 230V, coated)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X307-2 EEC (2x 24V)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X307-2 EEC (2x 24V, coated)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X307-3",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X307-3",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X307-3LD",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X307-3LD",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2LD",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2LD",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2LH",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2LH",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2LH+",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2LH+",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2M",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2M",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2M PoE",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2M PoE",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2M TS",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2M TS",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X310",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X310",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X310FE",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X310FE",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X320-1 FE",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X320-1-2LD FE",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X408-2",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-12M (230V, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-12M (230V, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-12M (230V, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-12M (230V, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-12M (24V, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-12M (24V, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-12M (24V, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-12M (24V, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-12M TS (24V)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-12M TS (24V)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (24V, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (24V, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (24V, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (24V, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (2x 24V, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (2x 24V, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (2x 24V, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (2x 24V, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M PoE (230V, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M PoE (230V, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M PoE (24V, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M PoE (24V, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M PoE TS (24V, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIPLUS NET SCALANCE X308-2",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in SCALANCE X302-7 EEC (230V), SCALANCE X302-7 EEC (230V, coated), SCALANCE X302-7 EEC (24V), SCALANCE X302-7 EEC (24V, coated), SCALANCE X302-7 EEC (2x 230V), SCALANCE X302-7 EEC (2x 230V, coated), SCALANCE X302-7 EEC (2x 24V), SCALANCE X302-7 EEC (2x 24V, coated), SCALANCE X304-2FE, SCALANCE X306-1LD FE, SCALANCE X307-2 EEC (230V), SCALANCE X307-2 EEC (230V, coated), SCALANCE X307-2 EEC (24V), SCALANCE X307-2 EEC (24V, coated), SCALANCE X307-2 EEC (2x 230V), SCALANCE X307-2 EEC (2x 230V, coated), SCALANCE X307-2 EEC (2x 24V), SCALANCE X307-2 EEC (2x 24V, coated), SCALANCE X307-3, SCALANCE X307-3, SCALANCE X307-3LD, SCALANCE X307-3LD, SCALANCE X308-2, SCALANCE X308-2, SCALANCE X308-2LD, SCALANCE X308-2LD, SCALANCE X308-2LH, SCALANCE X308-2LH, SCALANCE X308-2LH+, SCALANCE X308-2LH+, SCALANCE X308-2M, SCALANCE X308-2M, SCALANCE X308-2M PoE, SCALANCE X308-2M PoE, SCALANCE X308-2M TS, SCALANCE X308-2M TS, SCALANCE X310, SCALANCE X310, SCALANCE X310FE, SCALANCE X310FE, SCALANCE X320-1 FE, SCALANCE X320-1-2LD FE, SCALANCE X408-2, SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M TS (24V), SCALANCE XR324-12M TS (24V), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M PoE (230V, ports on front), SCALANCE XR324-4M PoE (230V, ports on rear), SCALANCE XR324-4M PoE (24V, ports on front), SCALANCE XR324-4M PoE (24V, ports on rear), SCALANCE XR324-4M PoE TS (24V, ports on front), SIPLUS NET SCALANCE X308-2. The integrated web server of the affected device could allow remote attackers to perform actions with the permissions of a victim user, provided the victim user has an active session and is induced to trigger the malicious request."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-352: Cross-Site Request Forgery (CSRF)"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-836527.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-836527.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2022-25754",
    "datePublished": "2022-04-12T09:07:49",
    "dateReserved": "2022-02-22T00:00:00",
    "dateUpdated": "2024-08-03T04:49:43.242Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2022-26334
Vulnerability from cvelistv5
Published
2022-04-12 09:07
Modified
2024-08-03 05:03
Severity
Summary
A vulnerability has been identified in SCALANCE X302-7 EEC (230V), SCALANCE X302-7 EEC (230V, coated), SCALANCE X302-7 EEC (24V), SCALANCE X302-7 EEC (24V, coated), SCALANCE X302-7 EEC (2x 230V), SCALANCE X302-7 EEC (2x 230V, coated), SCALANCE X302-7 EEC (2x 24V), SCALANCE X302-7 EEC (2x 24V, coated), SCALANCE X304-2FE, SCALANCE X306-1LD FE, SCALANCE X307-2 EEC (230V), SCALANCE X307-2 EEC (230V, coated), SCALANCE X307-2 EEC (24V), SCALANCE X307-2 EEC (24V, coated), SCALANCE X307-2 EEC (2x 230V), SCALANCE X307-2 EEC (2x 230V, coated), SCALANCE X307-2 EEC (2x 24V), SCALANCE X307-2 EEC (2x 24V, coated), SCALANCE X307-3, SCALANCE X307-3, SCALANCE X307-3LD, SCALANCE X307-3LD, SCALANCE X308-2, SCALANCE X308-2, SCALANCE X308-2LD, SCALANCE X308-2LD, SCALANCE X308-2LH, SCALANCE X308-2LH, SCALANCE X308-2LH+, SCALANCE X308-2LH+, SCALANCE X308-2M, SCALANCE X308-2M, SCALANCE X308-2M PoE, SCALANCE X308-2M PoE, SCALANCE X308-2M TS, SCALANCE X308-2M TS, SCALANCE X310, SCALANCE X310, SCALANCE X310FE, SCALANCE X310FE, SCALANCE X320-1 FE, SCALANCE X320-1-2LD FE, SCALANCE X408-2, SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M TS (24V), SCALANCE XR324-12M TS (24V), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M PoE (230V, ports on front), SCALANCE XR324-4M PoE (230V, ports on rear), SCALANCE XR324-4M PoE (24V, ports on front), SCALANCE XR324-4M PoE (24V, ports on rear), SCALANCE XR324-4M PoE TS (24V, ports on front), SIPLUS NET SCALANCE X308-2. Affected devices do not properly validate the GET parameter XNo of incoming HTTP requests. This could allow an unauthenticated remote attacker to crash affected devices.
Impacted products
VendorProduct
SiemensSCALANCE X302-7 EEC (230V)
SiemensSCALANCE X302-7 EEC (230V, coated)
SiemensSCALANCE X302-7 EEC (24V)
SiemensSCALANCE X302-7 EEC (24V, coated)
SiemensSCALANCE X302-7 EEC (2x 230V)
SiemensSCALANCE X302-7 EEC (2x 230V, coated)
SiemensSCALANCE X302-7 EEC (2x 24V)
SiemensSCALANCE X302-7 EEC (2x 24V, coated)
SiemensSCALANCE X304-2FE
SiemensSCALANCE X306-1LD FE
SiemensSCALANCE X307-2 EEC (230V)
SiemensSCALANCE X307-2 EEC (230V, coated)
SiemensSCALANCE X307-2 EEC (24V)
SiemensSCALANCE X307-2 EEC (24V, coated)
SiemensSCALANCE X307-2 EEC (2x 230V)
SiemensSCALANCE X307-2 EEC (2x 230V, coated)
SiemensSCALANCE X307-2 EEC (2x 24V)
SiemensSCALANCE X307-2 EEC (2x 24V, coated)
SiemensSCALANCE X307-3
SiemensSCALANCE X307-3
SiemensSCALANCE X307-3LD
SiemensSCALANCE X307-3LD
SiemensSCALANCE X308-2
SiemensSCALANCE X308-2
SiemensSCALANCE X308-2LD
SiemensSCALANCE X308-2LD
SiemensSCALANCE X308-2LH
SiemensSCALANCE X308-2LH
SiemensSCALANCE X308-2LH+
SiemensSCALANCE X308-2LH+
SiemensSCALANCE X308-2M
SiemensSCALANCE X308-2M
SiemensSCALANCE X308-2M PoE
SiemensSCALANCE X308-2M PoE
SiemensSCALANCE X308-2M TS
SiemensSCALANCE X308-2M TS
SiemensSCALANCE X310
SiemensSCALANCE X310
SiemensSCALANCE X310FE
SiemensSCALANCE X310FE
SiemensSCALANCE X320-1 FE
SiemensSCALANCE X320-1-2LD FE
SiemensSCALANCE X408-2
SiemensSCALANCE XR324-12M (230V, ports on front)
SiemensSCALANCE XR324-12M (230V, ports on front)
SiemensSCALANCE XR324-12M (230V, ports on rear)
SiemensSCALANCE XR324-12M (230V, ports on rear)
SiemensSCALANCE XR324-12M (24V, ports on front)
SiemensSCALANCE XR324-12M (24V, ports on front)
SiemensSCALANCE XR324-12M (24V, ports on rear)
SiemensSCALANCE XR324-12M (24V, ports on rear)
SiemensSCALANCE XR324-12M TS (24V)
SiemensSCALANCE XR324-12M TS (24V)
SiemensSCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)
SiemensSCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)
SiemensSCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)
SiemensSCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)
SiemensSCALANCE XR324-4M EEC (24V, ports on front)
SiemensSCALANCE XR324-4M EEC (24V, ports on front)
SiemensSCALANCE XR324-4M EEC (24V, ports on rear)
SiemensSCALANCE XR324-4M EEC (24V, ports on rear)
SiemensSCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)
SiemensSCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)
SiemensSCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)
SiemensSCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)
SiemensSCALANCE XR324-4M EEC (2x 24V, ports on front)
SiemensSCALANCE XR324-4M EEC (2x 24V, ports on front)
SiemensSCALANCE XR324-4M EEC (2x 24V, ports on rear)
SiemensSCALANCE XR324-4M EEC (2x 24V, ports on rear)
SiemensSCALANCE XR324-4M PoE (230V, ports on front)
SiemensSCALANCE XR324-4M PoE (230V, ports on rear)
SiemensSCALANCE XR324-4M PoE (24V, ports on front)
SiemensSCALANCE XR324-4M PoE (24V, ports on rear)
SiemensSCALANCE XR324-4M PoE TS (24V, ports on front)
SiemensSIPLUS NET SCALANCE X308-2
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T05:03:32.480Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-836527.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "SCALANCE X302-7 EEC (230V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X302-7 EEC (230V, coated)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X302-7 EEC (24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X302-7 EEC (24V, coated)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X302-7 EEC (2x 230V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X302-7 EEC (2x 230V, coated)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X302-7 EEC (2x 24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X302-7 EEC (2x 24V, coated)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X304-2FE",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X306-1LD FE",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X307-2 EEC (230V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X307-2 EEC (230V, coated)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X307-2 EEC (24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X307-2 EEC (24V, coated)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X307-2 EEC (2x 230V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X307-2 EEC (2x 230V, coated)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X307-2 EEC (2x 24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X307-2 EEC (2x 24V, coated)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X307-3",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X307-3",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X307-3LD",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X307-3LD",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2LD",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2LD",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2LH",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2LH",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2LH+",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2LH+",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2M",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2M",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2M PoE",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2M PoE",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2M TS",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2M TS",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X310",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X310",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X310FE",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X310FE",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X320-1 FE",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X320-1-2LD FE",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X408-2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-12M (230V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-12M (230V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-12M (230V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-12M (230V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-12M (24V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-12M (24V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-12M (24V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-12M (24V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-12M TS (24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-12M TS (24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (24V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (24V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (24V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (24V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (2x 24V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (2x 24V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (2x 24V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (2x 24V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M PoE (230V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M PoE (230V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M PoE (24V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M PoE (24V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M PoE TS (24V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SIPLUS NET SCALANCE X308-2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in SCALANCE X302-7 EEC (230V), SCALANCE X302-7 EEC (230V, coated), SCALANCE X302-7 EEC (24V), SCALANCE X302-7 EEC (24V, coated), SCALANCE X302-7 EEC (2x 230V), SCALANCE X302-7 EEC (2x 230V, coated), SCALANCE X302-7 EEC (2x 24V), SCALANCE X302-7 EEC (2x 24V, coated), SCALANCE X304-2FE, SCALANCE X306-1LD FE, SCALANCE X307-2 EEC (230V), SCALANCE X307-2 EEC (230V, coated), SCALANCE X307-2 EEC (24V), SCALANCE X307-2 EEC (24V, coated), SCALANCE X307-2 EEC (2x 230V), SCALANCE X307-2 EEC (2x 230V, coated), SCALANCE X307-2 EEC (2x 24V), SCALANCE X307-2 EEC (2x 24V, coated), SCALANCE X307-3, SCALANCE X307-3, SCALANCE X307-3LD, SCALANCE X307-3LD, SCALANCE X308-2, SCALANCE X308-2, SCALANCE X308-2LD, SCALANCE X308-2LD, SCALANCE X308-2LH, SCALANCE X308-2LH, SCALANCE X308-2LH+, SCALANCE X308-2LH+, SCALANCE X308-2M, SCALANCE X308-2M, SCALANCE X308-2M PoE, SCALANCE X308-2M PoE, SCALANCE X308-2M TS, SCALANCE X308-2M TS, SCALANCE X310, SCALANCE X310, SCALANCE X310FE, SCALANCE X310FE, SCALANCE X320-1 FE, SCALANCE X320-1-2LD FE, SCALANCE X408-2, SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M TS (24V), SCALANCE XR324-12M TS (24V), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M PoE (230V, ports on front), SCALANCE XR324-4M PoE (230V, ports on rear), SCALANCE XR324-4M PoE (24V, ports on front), SCALANCE XR324-4M PoE (24V, ports on rear), SCALANCE XR324-4M PoE TS (24V, ports on front), SIPLUS NET SCALANCE X308-2. Affected devices do not properly validate the GET parameter XNo of incoming HTTP requests. This could allow an unauthenticated remote attacker to crash affected devices."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-120",
              "description": "CWE-120: Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-04-12T09:07:54",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-836527.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2022-26334",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "SCALANCE X302-7 EEC (230V)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X302-7 EEC (230V, coated)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X302-7 EEC (24V)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X302-7 EEC (24V, coated)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X302-7 EEC (2x 230V)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X302-7 EEC (2x 230V, coated)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X302-7 EEC (2x 24V)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X302-7 EEC (2x 24V, coated)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X304-2FE",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X306-1LD FE",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X307-2 EEC (230V)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X307-2 EEC (230V, coated)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X307-2 EEC (24V)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X307-2 EEC (24V, coated)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X307-2 EEC (2x 230V)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X307-2 EEC (2x 230V, coated)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X307-2 EEC (2x 24V)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X307-2 EEC (2x 24V, coated)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X307-3",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X307-3",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X307-3LD",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X307-3LD",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2LD",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2LD",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2LH",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2LH",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2LH+",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2LH+",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2M",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2M",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2M PoE",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2M PoE",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2M TS",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2M TS",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X310",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X310",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X310FE",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X310FE",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X320-1 FE",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X320-1-2LD FE",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X408-2",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-12M (230V, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-12M (230V, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-12M (230V, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-12M (230V, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-12M (24V, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-12M (24V, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-12M (24V, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-12M (24V, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-12M TS (24V)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-12M TS (24V)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (24V, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (24V, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (24V, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (24V, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (2x 24V, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (2x 24V, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (2x 24V, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (2x 24V, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M PoE (230V, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M PoE (230V, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M PoE (24V, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M PoE (24V, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M PoE TS (24V, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIPLUS NET SCALANCE X308-2",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in SCALANCE X302-7 EEC (230V), SCALANCE X302-7 EEC (230V, coated), SCALANCE X302-7 EEC (24V), SCALANCE X302-7 EEC (24V, coated), SCALANCE X302-7 EEC (2x 230V), SCALANCE X302-7 EEC (2x 230V, coated), SCALANCE X302-7 EEC (2x 24V), SCALANCE X302-7 EEC (2x 24V, coated), SCALANCE X304-2FE, SCALANCE X306-1LD FE, SCALANCE X307-2 EEC (230V), SCALANCE X307-2 EEC (230V, coated), SCALANCE X307-2 EEC (24V), SCALANCE X307-2 EEC (24V, coated), SCALANCE X307-2 EEC (2x 230V), SCALANCE X307-2 EEC (2x 230V, coated), SCALANCE X307-2 EEC (2x 24V), SCALANCE X307-2 EEC (2x 24V, coated), SCALANCE X307-3, SCALANCE X307-3, SCALANCE X307-3LD, SCALANCE X307-3LD, SCALANCE X308-2, SCALANCE X308-2, SCALANCE X308-2LD, SCALANCE X308-2LD, SCALANCE X308-2LH, SCALANCE X308-2LH, SCALANCE X308-2LH+, SCALANCE X308-2LH+, SCALANCE X308-2M, SCALANCE X308-2M, SCALANCE X308-2M PoE, SCALANCE X308-2M PoE, SCALANCE X308-2M TS, SCALANCE X308-2M TS, SCALANCE X310, SCALANCE X310, SCALANCE X310FE, SCALANCE X310FE, SCALANCE X320-1 FE, SCALANCE X320-1-2LD FE, SCALANCE X408-2, SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M TS (24V), SCALANCE XR324-12M TS (24V), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M PoE (230V, ports on front), SCALANCE XR324-4M PoE (230V, ports on rear), SCALANCE XR324-4M PoE (24V, ports on front), SCALANCE XR324-4M PoE (24V, ports on rear), SCALANCE XR324-4M PoE TS (24V, ports on front), SIPLUS NET SCALANCE X308-2. Affected devices do not properly validate the GET parameter XNo of incoming HTTP requests. This could allow an unauthenticated remote attacker to crash affected devices."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-120: Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-836527.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-836527.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2022-26334",
    "datePublished": "2022-04-12T09:07:54",
    "dateReserved": "2022-03-01T00:00:00",
    "dateUpdated": "2024-08-03T05:03:32.480Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2019-6569
Vulnerability from cvelistv5
Published
2019-03-26 21:12
Modified
2024-08-04 20:23
Severity
Summary
The monitor barrier of the affected products insufficiently blocks data from being forwarded over the mirror port into the mirrored network. An attacker could use this behavior to transmit malicious packets to systems in the mirrored network, possibly influencing their configuration and runtime behavior.
Impacted products
VendorProduct
SiemensSCALANCE X204-2
SiemensSCALANCE X204-2FM
SiemensSCALANCE X204-2LD
SiemensSCALANCE X204-2LD TS
SiemensSCALANCE X204-2TS
SiemensSCALANCE X206-1
SiemensSCALANCE X206-1LD
SiemensSCALANCE X208
SiemensSCALANCE X208PRO
SiemensSCALANCE X212-2
SiemensSCALANCE X212-2LD
SiemensSCALANCE X216
SiemensSCALANCE X224
SiemensSCALANCE X302-7 EEC (230V)
SiemensSCALANCE X302-7 EEC (230V, coated)
SiemensSCALANCE X302-7 EEC (24V)
SiemensSCALANCE X302-7 EEC (24V, coated)
SiemensSCALANCE X302-7 EEC (2x 230V)
SiemensSCALANCE X302-7 EEC (2x 230V, coated)
SiemensSCALANCE X302-7 EEC (2x 24V)
SiemensSCALANCE X302-7 EEC (2x 24V, coated)
SiemensSCALANCE X304-2FE
SiemensSCALANCE X306-1LD FE
SiemensSCALANCE X307-2 EEC (230V)
SiemensSCALANCE X307-2 EEC (230V, coated)
SiemensSCALANCE X307-2 EEC (24V)
SiemensSCALANCE X307-2 EEC (24V, coated)
SiemensSCALANCE X307-2 EEC (2x 230V)
SiemensSCALANCE X307-2 EEC (2x 230V, coated)
SiemensSCALANCE X307-2 EEC (2x 24V)
SiemensSCALANCE X307-2 EEC (2x 24V, coated)
SiemensSCALANCE X307-3
SiemensSCALANCE X307-3
SiemensSCALANCE X307-3LD
SiemensSCALANCE X307-3LD
SiemensSCALANCE X308-2
SiemensSCALANCE X308-2
SiemensSCALANCE X308-2LD
SiemensSCALANCE X308-2LD
SiemensSCALANCE X308-2LH
SiemensSCALANCE X308-2LH
SiemensSCALANCE X308-2LH+
SiemensSCALANCE X308-2LH+
SiemensSCALANCE X308-2M
SiemensSCALANCE X308-2M
SiemensSCALANCE X308-2M PoE
SiemensSCALANCE X308-2M PoE
SiemensSCALANCE X308-2M TS
SiemensSCALANCE X308-2M TS
SiemensSCALANCE X310
SiemensSCALANCE X310
SiemensSCALANCE X310FE
SiemensSCALANCE X310FE
SiemensSCALANCE X320-1 FE
SiemensSCALANCE X320-1-2LD FE
SiemensSCALANCE X408-2
SiemensSCALANCE XB205-3 (SC)
SiemensSCALANCE XB205-3 (SC)
SiemensSCALANCE XB205-3 (ST/BFOC)
SiemensSCALANCE XB205-3 (ST/BFOC)
SiemensSCALANCE XB205-3LD
SiemensSCALANCE XB205-3LD
SiemensSCALANCE XB208
SiemensSCALANCE XB208
SiemensSCALANCE XB213-3 (SC)
SiemensSCALANCE XB213-3 (SC)
SiemensSCALANCE XB213-3 (ST/BFOC)
SiemensSCALANCE XB213-3 (ST/BFOC)
SiemensSCALANCE XB213-3LD
SiemensSCALANCE XB213-3LD
SiemensSCALANCE XB216
SiemensSCALANCE XB216
SiemensSCALANCE XC206-2 (SC)
SiemensSCALANCE XC206-2 (ST/BFOC)
SiemensSCALANCE XC206-2SFP
SiemensSCALANCE XC206-2SFP EEC
SiemensSCALANCE XC206-2SFP G
SiemensSCALANCE XC206-2SFP G
SiemensSCALANCE XC206-2SFP G EEC
SiemensSCALANCE XC208
SiemensSCALANCE XC208EEC
SiemensSCALANCE XC208G
SiemensSCALANCE XC208G
SiemensSCALANCE XC208G EEC
SiemensSCALANCE XC216
SiemensSCALANCE XC216-4C
SiemensSCALANCE XC216-4C G
SiemensSCALANCE XC216-4C G (EIP Def.)
SiemensSCALANCE XC216-4C G EEC
SiemensSCALANCE XC216EEC
SiemensSCALANCE XC224
SiemensSCALANCE XC224-4C G
SiemensSCALANCE XC224-4C G (EIP Def.)
SiemensSCALANCE XC224-4C G EEC
SiemensSCALANCE XF204
SiemensSCALANCE XF204
SiemensSCALANCE XF204 DNA
SiemensSCALANCE XF204-2
SiemensSCALANCE XF204-2BA
SiemensSCALANCE XF204-2BA DNA
SiemensSCALANCE XF206-1
SiemensSCALANCE XF208
SiemensSCALANCE XP208
SiemensSCALANCE XP208
SiemensSCALANCE XP208EEC
SiemensSCALANCE XP208PoE EEC
SiemensSCALANCE XP216
SiemensSCALANCE XP216
SiemensSCALANCE XP216EEC
SiemensSCALANCE XP216POE EEC
SiemensSCALANCE XR324-12M (230V, ports on front)
SiemensSCALANCE XR324-12M (230V, ports on front)
SiemensSCALANCE XR324-12M (230V, ports on rear)
SiemensSCALANCE XR324-12M (230V, ports on rear)
SiemensSCALANCE XR324-12M (24V, ports on front)
SiemensSCALANCE XR324-12M (24V, ports on front)
SiemensSCALANCE XR324-12M (24V, ports on rear)
SiemensSCALANCE XR324-12M (24V, ports on rear)
SiemensSCALANCE XR324-12M TS (24V)
SiemensSCALANCE XR324-12M TS (24V)
SiemensSCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)
SiemensSCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)
SiemensSCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)
SiemensSCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)
SiemensSCALANCE XR324-4M EEC (24V, ports on front)
SiemensSCALANCE XR324-4M EEC (24V, ports on front)
SiemensSCALANCE XR324-4M EEC (24V, ports on rear)
SiemensSCALANCE XR324-4M EEC (24V, ports on rear)
SiemensSCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)
SiemensSCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)
SiemensSCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)
SiemensSCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)
SiemensSCALANCE XR324-4M EEC (2x 24V, ports on front)
SiemensSCALANCE XR324-4M EEC (2x 24V, ports on front)
SiemensSCALANCE XR324-4M EEC (2x 24V, ports on rear)
SiemensSCALANCE XR324-4M EEC (2x 24V, ports on rear)
SiemensSCALANCE XR324-4M PoE (230V, ports on front)
SiemensSCALANCE XR324-4M PoE (230V, ports on front)
SiemensSCALANCE XR324-4M PoE (230V, ports on rear)
SiemensSCALANCE XR324-4M PoE (230V, ports on rear)
SiemensSCALANCE XR324-4M PoE (24V, ports on front)
SiemensSCALANCE XR324-4M PoE (24V, ports on front)
SiemensSCALANCE XR324-4M PoE (24V, ports on rear)
SiemensSCALANCE XR324-4M PoE (24V, ports on rear)
SiemensSCALANCE XR324-4M PoE TS (24V, ports on front)
SiemensSCALANCE XR324-4M PoE TS (24V, ports on front)
SiemensSCALANCE XR324WG (24 X FE, DC 24V)
SiemensSCALANCE XR324WG (24 x FE, AC 230V)
SiemensSCALANCE XR328-4C WG (24XFE, 4XGE, 24V)
SiemensSCALANCE XR328-4C WG (24xFE, 4xGE,DC24V)
SiemensSCALANCE XR328-4C WG (24xFE,4xGE,AC230V)
SiemensSCALANCE XR328-4C WG (24xFE,4xGE,AC230V)
SiemensSCALANCE XR328-4C WG (28xGE, AC 230V)
SiemensSCALANCE XR328-4C WG (28xGE, DC 24V)
SiemensSIPLUS NET SCALANCE X308-2
SiemensSIPLUS NET SCALANCE XC206-2
SiemensSIPLUS NET SCALANCE XC206-2SFP
SiemensSIPLUS NET SCALANCE XC208
SiemensSIPLUS NET SCALANCE XC216-4C
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T20:23:22.201Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-557804.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "SCALANCE X204-2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.2.6"
            }
          ]
        },
        {
          "product": "SCALANCE X204-2FM",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.2.6"
            }
          ]
        },
        {
          "product": "SCALANCE X204-2LD",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.2.6"
            }
          ]
        },
        {
          "product": "SCALANCE X204-2LD TS",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.2.6"
            }
          ]
        },
        {
          "product": "SCALANCE X204-2TS",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.2.6"
            }
          ]
        },
        {
          "product": "SCALANCE X206-1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.2.6"
            }
          ]
        },
        {
          "product": "SCALANCE X206-1LD",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.2.6"
            }
          ]
        },
        {
          "product": "SCALANCE X208",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.2.6"
            }
          ]
        },
        {
          "product": "SCALANCE X208PRO",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.2.6"
            }
          ]
        },
        {
          "product": "SCALANCE X212-2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.2.6"
            }
          ]
        },
        {
          "product": "SCALANCE X212-2LD",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.2.6"
            }
          ]
        },
        {
          "product": "SCALANCE X216",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.2.6"
            }
          ]
        },
        {
          "product": "SCALANCE X224",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.2.6"
            }
          ]
        },
        {
          "product": "SCALANCE X302-7 EEC (230V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE X302-7 EEC (230V, coated)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE X302-7 EEC (24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE X302-7 EEC (24V, coated)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE X302-7 EEC (2x 230V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE X302-7 EEC (2x 230V, coated)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE X302-7 EEC (2x 24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE X302-7 EEC (2x 24V, coated)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE X304-2FE",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE X306-1LD FE",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE X307-2 EEC (230V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE X307-2 EEC (230V, coated)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE X307-2 EEC (24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE X307-2 EEC (24V, coated)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE X307-2 EEC (2x 230V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE X307-2 EEC (2x 230V, coated)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE X307-2 EEC (2x 24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE X307-2 EEC (2x 24V, coated)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE X307-3",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE X307-3",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE X307-3LD",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE X307-3LD",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2LD",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2LD",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2LH",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2LH",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2LH+",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2LH+",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2M",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2M",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2M PoE",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2M PoE",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2M TS",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2M TS",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE X310",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE X310",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE X310FE",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE X310FE",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE X320-1 FE",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE X320-1-2LD FE",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE X408-2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE XB205-3 (SC)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1"
            }
          ]
        },
        {
          "product": "SCALANCE XB205-3 (SC)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1"
            }
          ]
        },
        {
          "product": "SCALANCE XB205-3 (ST/BFOC)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1"
            }
          ]
        },
        {
          "product": "SCALANCE XB205-3 (ST/BFOC)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1"
            }
          ]
        },
        {
          "product": "SCALANCE XB205-3LD",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1"
            }
          ]
        },
        {
          "product": "SCALANCE XB205-3LD",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1"
            }
          ]
        },
        {
          "product": "SCALANCE XB208",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1"
            }
          ]
        },
        {
          "product": "SCALANCE XB208",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1"
            }
          ]
        },
        {
          "product": "SCALANCE XB213-3 (SC)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1"
            }
          ]
        },
        {
          "product": "SCALANCE XB213-3 (SC)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1"
            }
          ]
        },
        {
          "product": "SCALANCE XB213-3 (ST/BFOC)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1"
            }
          ]
        },
        {
          "product": "SCALANCE XB213-3 (ST/BFOC)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1"
            }
          ]
        },
        {
          "product": "SCALANCE XB213-3LD",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1"
            }
          ]
        },
        {
          "product": "SCALANCE XB213-3LD",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1"
            }
          ]
        },
        {
          "product": "SCALANCE XB216",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1"
            }
          ]
        },
        {
          "product": "SCALANCE XB216",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1"
            }
          ]
        },
        {
          "product": "SCALANCE XC206-2 (SC)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1"
            }
          ]
        },
        {
          "product": "SCALANCE XC206-2 (ST/BFOC)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1"
            }
          ]
        },
        {
          "product": "SCALANCE XC206-2SFP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1"
            }
          ]
        },
        {
          "product": "SCALANCE XC206-2SFP EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1"
            }
          ]
        },
        {
          "product": "SCALANCE XC206-2SFP G",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1"
            }
          ]
        },
        {
          "product": "SCALANCE XC206-2SFP G",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1"
            }
          ]
        },
        {
          "product": "SCALANCE XC206-2SFP G EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1"
            }
          ]
        },
        {
          "product": "SCALANCE XC208",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1"
            }
          ]
        },
        {
          "product": "SCALANCE XC208EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1"
            }
          ]
        },
        {
          "product": "SCALANCE XC208G",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1"
            }
          ]
        },
        {
          "product": "SCALANCE XC208G",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1"
            }
          ]
        },
        {
          "product": "SCALANCE XC208G EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1"
            }
          ]
        },
        {
          "product": "SCALANCE XC216",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1"
            }
          ]
        },
        {
          "product": "SCALANCE XC216-4C",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1"
            }
          ]
        },
        {
          "product": "SCALANCE XC216-4C G",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1"
            }
          ]
        },
        {
          "product": "SCALANCE XC216-4C G (EIP Def.)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1"
            }
          ]
        },
        {
          "product": "SCALANCE XC216-4C G EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1"
            }
          ]
        },
        {
          "product": "SCALANCE XC216EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1"
            }
          ]
        },
        {
          "product": "SCALANCE XC224",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1"
            }
          ]
        },
        {
          "product": "SCALANCE XC224-4C G",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1"
            }
          ]
        },
        {
          "product": "SCALANCE XC224-4C G (EIP Def.)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1"
            }
          ]
        },
        {
          "product": "SCALANCE XC224-4C G EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1"
            }
          ]
        },
        {
          "product": "SCALANCE XF204",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.2.6"
            }
          ]
        },
        {
          "product": "SCALANCE XF204",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1"
            }
          ]
        },
        {
          "product": "SCALANCE XF204 DNA",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1"
            }
          ]
        },
        {
          "product": "SCALANCE XF204-2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.2.6"
            }
          ]
        },
        {
          "product": "SCALANCE XF204-2BA",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1"
            }
          ]
        },
        {
          "product": "SCALANCE XF204-2BA DNA",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1"
            }
          ]
        },
        {
          "product": "SCALANCE XF206-1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.2.6"
            }
          ]
        },
        {
          "product": "SCALANCE XF208",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.2.6"
            }
          ]
        },
        {
          "product": "SCALANCE XP208",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1"
            }
          ]
        },
        {
          "product": "SCALANCE XP208",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1"
            }
          ]
        },
        {
          "product": "SCALANCE XP208EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1"
            }
          ]
        },
        {
          "product": "SCALANCE XP208PoE EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1"
            }
          ]
        },
        {
          "product": "SCALANCE XP216",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1"
            }
          ]
        },
        {
          "product": "SCALANCE XP216",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1"
            }
          ]
        },
        {
          "product": "SCALANCE XP216EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1"
            }
          ]
        },
        {
          "product": "SCALANCE XP216POE EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-12M (230V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-12M (230V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-12M (230V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-12M (230V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-12M (24V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-12M (24V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-12M (24V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-12M (24V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-12M TS (24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-12M TS (24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (24V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (24V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (24V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (24V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (2x 24V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (2x 24V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (2x 24V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (2x 24V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M PoE (230V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M PoE (230V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M PoE (230V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M PoE (230V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M PoE (24V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M PoE (24V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M PoE (24V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M PoE (24V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M PoE TS (24V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M PoE TS (24V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SCALANCE XR324WG (24 X FE, DC 24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1"
            }
          ]
        },
        {
          "product": "SCALANCE XR324WG (24 x FE, AC 230V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1"
            }
          ]
        },
        {
          "product": "SCALANCE XR328-4C WG (24XFE, 4XGE, 24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1"
            }
          ]
        },
        {
          "product": "SCALANCE XR328-4C WG (24xFE, 4xGE,DC24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1"
            }
          ]
        },
        {
          "product": "SCALANCE XR328-4C WG (24xFE,4xGE,AC230V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1"
            }
          ]
        },
        {
          "product": "SCALANCE XR328-4C WG (24xFE,4xGE,AC230V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1"
            }
          ]
        },
        {
          "product": "SCALANCE XR328-4C WG (28xGE, AC 230V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1"
            }
          ]
        },
        {
          "product": "SCALANCE XR328-4C WG (28xGE, DC 24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1"
            }
          ]
        },
        {
          "product": "SIPLUS NET SCALANCE X308-2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "product": "SIPLUS NET SCALANCE XC206-2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1"
            }
          ]
        },
        {
          "product": "SIPLUS NET SCALANCE XC206-2SFP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1"
            }
          ]
        },
        {
          "product": "SIPLUS NET SCALANCE XC208",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1"
            }
          ]
        },
        {
          "product": "SIPLUS NET SCALANCE XC216-4C",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1"
            }
          ]
        }
      ],
      "datePublic": "2019-03-12T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "The monitor barrier of the affected products insufficiently blocks data from being forwarded over the mirror port into the mirrored network. An attacker could use this behavior to transmit malicious packets to systems in the mirrored network, possibly influencing their configuration and runtime behavior."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-440",
              "description": "CWE-440: Expected Behavior Violation",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-07-12T10:06:21",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-557804.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2019-6569",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "SCALANCE X204-2",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V5.2.6"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X204-2FM",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V5.2.6"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X204-2LD",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V5.2.6"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X204-2LD TS",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V5.2.6"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X204-2TS",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V5.2.6"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X206-1",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V5.2.6"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X206-1LD",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V5.2.6"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X208",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V5.2.6"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X208PRO",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V5.2.6"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X212-2",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V5.2.6"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X212-2LD",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V5.2.6"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X216",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V5.2.6"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X224",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V5.2.6"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X302-7 EEC (230V)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X302-7 EEC (230V, coated)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X302-7 EEC (24V)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X302-7 EEC (24V, coated)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X302-7 EEC (2x 230V)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X302-7 EEC (2x 230V, coated)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X302-7 EEC (2x 24V)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X302-7 EEC (2x 24V, coated)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X304-2FE",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X306-1LD FE",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X307-2 EEC (230V)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X307-2 EEC (230V, coated)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X307-2 EEC (24V)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X307-2 EEC (24V, coated)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X307-2 EEC (2x 230V)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X307-2 EEC (2x 230V, coated)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X307-2 EEC (2x 24V)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X307-2 EEC (2x 24V, coated)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X307-3",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X307-3",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X307-3LD",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X307-3LD",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2LD",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2LD",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2LH",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2LH",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2LH+",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2LH+",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2M",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2M",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2M PoE",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2M PoE",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2M TS",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2M TS",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X310",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X310",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X310FE",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X310FE",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X320-1 FE",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X320-1-2LD FE",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X408-2",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XB205-3 (SC)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XB205-3 (SC)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XB205-3 (ST/BFOC)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XB205-3 (ST/BFOC)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XB205-3LD",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XB205-3LD",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XB208",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XB208",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XB213-3 (SC)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XB213-3 (SC)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XB213-3 (ST/BFOC)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XB213-3 (ST/BFOC)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XB213-3LD",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XB213-3LD",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XB216",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XB216",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XC206-2 (SC)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XC206-2 (ST/BFOC)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XC206-2SFP",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XC206-2SFP EEC",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XC206-2SFP G",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XC206-2SFP G",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XC206-2SFP G EEC",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XC208",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XC208EEC",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XC208G",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XC208G",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XC208G EEC",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XC216",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XC216-4C",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XC216-4C G",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XC216-4C G (EIP Def.)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XC216-4C G EEC",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XC216EEC",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XC224",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XC224-4C G",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XC224-4C G (EIP Def.)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XC224-4C G EEC",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XF204",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V5.2.6"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XF204",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XF204 DNA",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XF204-2",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V5.2.6"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XF204-2BA",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XF204-2BA DNA",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XF206-1",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V5.2.6"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XF208",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V5.2.6"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XP208",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XP208",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XP208EEC",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XP208PoE EEC",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XP216",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XP216",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XP216EEC",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XP216POE EEC",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-12M (230V, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-12M (230V, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-12M (230V, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-12M (230V, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-12M (24V, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-12M (24V, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-12M (24V, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-12M (24V, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-12M TS (24V)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-12M TS (24V)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (24V, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (24V, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (24V, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (24V, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (2x 24V, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (2x 24V, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (2x 24V, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (2x 24V, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M PoE (230V, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M PoE (230V, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M PoE (230V, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M PoE (230V, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M PoE (24V, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M PoE (24V, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M PoE (24V, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M PoE (24V, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M PoE TS (24V, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M PoE TS (24V, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324WG (24 X FE, DC 24V)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324WG (24 x FE, AC 230V)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR328-4C WG (24XFE, 4XGE, 24V)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR328-4C WG (24xFE, 4xGE,DC24V)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR328-4C WG (24xFE,4xGE,AC230V)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR328-4C WG (24xFE,4xGE,AC230V)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR328-4C WG (28xGE, AC 230V)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR328-4C WG (28xGE, DC 24V)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIPLUS NET SCALANCE X308-2",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIPLUS NET SCALANCE XC206-2",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIPLUS NET SCALANCE XC206-2SFP",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIPLUS NET SCALANCE XC208",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIPLUS NET SCALANCE XC216-4C",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "The monitor barrier of the affected products insufficiently blocks data from being forwarded over the mirror port into the mirrored network. An attacker could use this behavior to transmit malicious packets to systems in the mirrored network, possibly influencing their configuration and runtime behavior."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-440: Expected Behavior Violation"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-557804.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-557804.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2019-6569",
    "datePublished": "2019-03-26T21:12:43",
    "dateReserved": "2019-01-22T00:00:00",
    "dateUpdated": "2024-08-04T20:23:22.201Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",