103 vulnerabilities found for SIMATIC WinCC by Siemens
VAR-202402-1390
Vulnerability from variot - Updated: 2024-06-11 23:02A vulnerability has been identified in OpenPCS 7 V9.1 (All versions), SIMATIC BATCH V9.1 (All versions), SIMATIC PCS 7 V9.1 (All versions), SIMATIC Route Control V9.1 (All versions), SIMATIC WinCC Runtime Professional V18 (All versions), SIMATIC WinCC Runtime Professional V19 (All versions < V19 Update 2), SIMATIC WinCC V7.4 (All versions), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 15), SIMATIC WinCC V8.0 (All versions < V8.0 Update 4). The implementation of the RPC (Remote Procedure call) communication protocol in the affected products do not properly handle certain unorganized RPC messages. An attacker could use this vulnerability to cause a denial of service condition in the RPC server. SIMATIC PCS 7 is a distributed control system (DCS) that integrates SIMATIC WinCC, SIMATIC Batch, SIMATIC Route control, OpenPCS 7 and other components. SIMATIC WinCC is a supervisory control and data acquisition (SCADA) system. SIMATIC WinCC Runtime Professional is a visual runtime platform for operator control and monitoring of machines and plants
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202402-1390",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "simatic wincc",
"scope": "eq",
"trust": 0.6,
"vendor": "siemens",
"version": "v7.4"
},
{
"model": "simatic pcs",
"scope": "eq",
"trust": 0.6,
"vendor": "siemens",
"version": "7v9.1"
},
{
"model": "openpcs",
"scope": "eq",
"trust": 0.6,
"vendor": "siemens",
"version": "79.1"
},
{
"model": "simatic batch",
"scope": "eq",
"trust": 0.6,
"vendor": "siemens",
"version": "9.1"
},
{
"model": "simatic route control",
"scope": "eq",
"trust": 0.6,
"vendor": "siemens",
"version": "9.1"
},
{
"model": "simatic wincc runtime professional",
"scope": "eq",
"trust": 0.6,
"vendor": "siemens",
"version": "v18"
},
{
"model": "simatic wincc runtime professional",
"scope": "eq",
"trust": 0.6,
"vendor": "siemens",
"version": "v19"
},
{
"model": "simatic wincc sp2 update",
"scope": "lt",
"trust": 0.6,
"vendor": "siemens",
"version": "7.515"
},
{
"model": "simatic wincc sp4",
"scope": "lt",
"trust": 0.6,
"vendor": "siemens",
"version": "8.0"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-09315"
}
]
},
"cve": "CVE-2023-48363",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "ADJACENT_NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 6.1,
"confidentialityImpact": "NONE",
"exploitabilityScore": 6.5,
"id": "CNVD-2024-09315",
"impactScore": 6.9,
"integrityImpact": "NONE",
"severity": "MEDIUM",
"trust": 0.6,
"vectorString": "AV:A/AC:L/Au:N/C:N/I:N/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"author": "productcert@siemens.com",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"exploitabilityScore": 2.8,
"impactScore": 3.6,
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
}
],
"severity": [
{
"author": "productcert@siemens.com",
"id": "CVE-2023-48363",
"trust": 1.0,
"value": "MEDIUM"
},
{
"author": "CNVD",
"id": "CNVD-2024-09315",
"trust": 0.6,
"value": "MEDIUM"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-09315"
},
{
"db": "NVD",
"id": "CVE-2023-48363"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "A vulnerability has been identified in OpenPCS 7 V9.1 (All versions), SIMATIC BATCH V9.1 (All versions), SIMATIC PCS 7 V9.1 (All versions), SIMATIC Route Control V9.1 (All versions), SIMATIC WinCC Runtime Professional V18 (All versions), SIMATIC WinCC Runtime Professional V19 (All versions \u003c V19 Update 2), SIMATIC WinCC V7.4 (All versions), SIMATIC WinCC V7.5 (All versions \u003c V7.5 SP2 Update 15), SIMATIC WinCC V8.0 (All versions \u003c V8.0 Update 4). The implementation of the RPC (Remote Procedure call) \r\ncommunication protocol in the affected products do not \r\nproperly handle certain unorganized RPC messages. An \r\nattacker could use this vulnerability to cause a denial of service \r\ncondition in the RPC server. SIMATIC PCS 7 is a distributed control system (DCS) that integrates SIMATIC WinCC, SIMATIC Batch, SIMATIC Route control, OpenPCS 7 and other components. SIMATIC WinCC is a supervisory control and data acquisition (SCADA) system. SIMATIC WinCC Runtime Professional is a visual runtime platform for operator control and monitoring of machines and plants",
"sources": [
{
"db": "NVD",
"id": "CVE-2023-48363"
},
{
"db": "CNVD",
"id": "CNVD-2024-09315"
},
{
"db": "VULMON",
"id": "CVE-2023-48363"
}
],
"trust": 1.53
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2023-48363",
"trust": 1.7
},
{
"db": "SIEMENS",
"id": "SSA-753746",
"trust": 1.7
},
{
"db": "CNVD",
"id": "CNVD-2024-09315",
"trust": 0.6
},
{
"db": "ICS CERT",
"id": "ICSA-24-046-12",
"trust": 0.1
},
{
"db": "VULMON",
"id": "CVE-2023-48363",
"trust": 0.1
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-09315"
},
{
"db": "VULMON",
"id": "CVE-2023-48363"
},
{
"db": "NVD",
"id": "CVE-2023-48363"
}
]
},
"id": "VAR-202402-1390",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-09315"
}
],
"trust": 1.2508139042857143
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"ICS"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-09315"
}
]
},
"last_update_date": "2024-06-11T23:02:21.168000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Patch for Null pointer dereference vulnerabilities in multiple Siemens products",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchinfo/show/526511"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-09315"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-476",
"trust": 1.0
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2023-48363"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.7,
"url": "https://cert-portal.siemens.com/productcert/html/ssa-753746.html"
},
{
"trust": 0.1,
"url": "https://cwe.mitre.org/data/definitions/476.html"
},
{
"trust": 0.1,
"url": "https://nvd.nist.gov"
},
{
"trust": 0.1,
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-046-12"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-09315"
},
{
"db": "VULMON",
"id": "CVE-2023-48363"
},
{
"db": "NVD",
"id": "CVE-2023-48363"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2024-09315"
},
{
"db": "VULMON",
"id": "CVE-2023-48363"
},
{
"db": "NVD",
"id": "CVE-2023-48363"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2024-02-23T00:00:00",
"db": "CNVD",
"id": "CNVD-2024-09315"
},
{
"date": "2024-02-13T00:00:00",
"db": "VULMON",
"id": "CVE-2023-48363"
},
{
"date": "2024-02-13T09:15:45.763000",
"db": "NVD",
"id": "CVE-2023-48363"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2024-02-21T00:00:00",
"db": "CNVD",
"id": "CNVD-2024-09315"
},
{
"date": "2024-02-13T00:00:00",
"db": "VULMON",
"id": "CVE-2023-48363"
},
{
"date": "2024-06-11T12:15:13.450000",
"db": "NVD",
"id": "CVE-2023-48363"
}
]
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Null pointer dereference vulnerabilities in multiple Siemens products",
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-09315"
}
],
"trust": 0.6
}
}
VAR-202402-1389
Vulnerability from variot - Updated: 2024-06-11 23:02A vulnerability has been identified in OpenPCS 7 V9.1 (All versions), SIMATIC BATCH V9.1 (All versions), SIMATIC PCS 7 V9.1 (All versions), SIMATIC Route Control V9.1 (All versions), SIMATIC WinCC Runtime Professional V18 (All versions), SIMATIC WinCC Runtime Professional V19 (All versions < V19 Update 2), SIMATIC WinCC V7.4 (All versions), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 15), SIMATIC WinCC V8.0 (All versions < V8.0 Update 4). The implementation of the RPC (Remote Procedure call) communication protocol in the affected products do not properly handle certain malformed RPC messages. An attacker could use this vulnerability to cause a denial of service condition in the RPC server. SIMATIC PCS 7 is a distributed control system (DCS) that integrates SIMATIC WinCC, SIMATIC Batch, SIMATIC Route control, OpenPCS 7 and other components. SIMATIC WinCC is a supervisory control and data acquisition (SCADA) system. SIMATIC WinCC Runtime Professional is a visual runtime platform for operator control and monitoring of machines and plants
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202402-1389",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "simatic wincc",
"scope": "eq",
"trust": 0.6,
"vendor": "siemens",
"version": "v7.4"
},
{
"model": "simatic pcs",
"scope": "eq",
"trust": 0.6,
"vendor": "siemens",
"version": "7v9.1"
},
{
"model": "openpcs",
"scope": "eq",
"trust": 0.6,
"vendor": "siemens",
"version": "79.1"
},
{
"model": "simatic batch",
"scope": "eq",
"trust": 0.6,
"vendor": "siemens",
"version": "9.1"
},
{
"model": "simatic route control",
"scope": "eq",
"trust": 0.6,
"vendor": "siemens",
"version": "9.1"
},
{
"model": "simatic wincc runtime professional",
"scope": "eq",
"trust": 0.6,
"vendor": "siemens",
"version": "v18"
},
{
"model": "simatic wincc runtime professional",
"scope": "eq",
"trust": 0.6,
"vendor": "siemens",
"version": "v19"
},
{
"model": "simatic wincc sp2 update",
"scope": "lt",
"trust": 0.6,
"vendor": "siemens",
"version": "7.515"
},
{
"model": "simatic wincc sp4",
"scope": "lt",
"trust": 0.6,
"vendor": "siemens",
"version": "8.0"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-09314"
}
]
},
"cve": "CVE-2023-48364",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "ADJACENT_NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 6.1,
"confidentialityImpact": "NONE",
"exploitabilityScore": 6.5,
"id": "CNVD-2024-09314",
"impactScore": 6.9,
"integrityImpact": "NONE",
"severity": "MEDIUM",
"trust": 0.6,
"vectorString": "AV:A/AC:L/Au:N/C:N/I:N/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"author": "productcert@siemens.com",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"exploitabilityScore": 2.8,
"impactScore": 3.6,
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
}
],
"severity": [
{
"author": "productcert@siemens.com",
"id": "CVE-2023-48364",
"trust": 1.0,
"value": "MEDIUM"
},
{
"author": "CNVD",
"id": "CNVD-2024-09314",
"trust": 0.6,
"value": "MEDIUM"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-09314"
},
{
"db": "NVD",
"id": "CVE-2023-48364"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "A vulnerability has been identified in OpenPCS 7 V9.1 (All versions), SIMATIC BATCH V9.1 (All versions), SIMATIC PCS 7 V9.1 (All versions), SIMATIC Route Control V9.1 (All versions), SIMATIC WinCC Runtime Professional V18 (All versions), SIMATIC WinCC Runtime Professional V19 (All versions \u003c V19 Update 2), SIMATIC WinCC V7.4 (All versions), SIMATIC WinCC V7.5 (All versions \u003c V7.5 SP2 Update 15), SIMATIC WinCC V8.0 (All versions \u003c V8.0 Update 4). The implementation of the RPC (Remote Procedure call) communication protocol in the affected products do not properly handle certain malformed RPC messages. An attacker could use this vulnerability to cause a denial of service condition in the RPC server. SIMATIC PCS 7 is a distributed control system (DCS) that integrates SIMATIC WinCC, SIMATIC Batch, SIMATIC Route control, OpenPCS 7 and other components. SIMATIC WinCC is a supervisory control and data acquisition (SCADA) system. SIMATIC WinCC Runtime Professional is a visual runtime platform for operator control and monitoring of machines and plants",
"sources": [
{
"db": "NVD",
"id": "CVE-2023-48364"
},
{
"db": "CNVD",
"id": "CNVD-2024-09314"
},
{
"db": "VULMON",
"id": "CVE-2023-48364"
}
],
"trust": 1.53
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2023-48364",
"trust": 1.7
},
{
"db": "SIEMENS",
"id": "SSA-753746",
"trust": 1.7
},
{
"db": "CNVD",
"id": "CNVD-2024-09314",
"trust": 0.6
},
{
"db": "ICS CERT",
"id": "ICSA-24-046-12",
"trust": 0.1
},
{
"db": "VULMON",
"id": "CVE-2023-48364",
"trust": 0.1
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-09314"
},
{
"db": "VULMON",
"id": "CVE-2023-48364"
},
{
"db": "NVD",
"id": "CVE-2023-48364"
}
]
},
"id": "VAR-202402-1389",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-09314"
}
],
"trust": 1.2508139042857143
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"ICS"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-09314"
}
]
},
"last_update_date": "2024-06-11T23:02:19.962000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Patch for Null pointer dereference vulnerability (CNVD-2024-09314) in multiple Siemens products",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchinfo/show/526516"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-09314"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-476",
"trust": 1.0
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2023-48364"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.7,
"url": "https://cert-portal.siemens.com/productcert/html/ssa-753746.html"
},
{
"trust": 0.1,
"url": "https://nvd.nist.gov"
},
{
"trust": 0.1,
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-046-12"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-09314"
},
{
"db": "VULMON",
"id": "CVE-2023-48364"
},
{
"db": "NVD",
"id": "CVE-2023-48364"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2024-09314"
},
{
"db": "VULMON",
"id": "CVE-2023-48364"
},
{
"db": "NVD",
"id": "CVE-2023-48364"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2024-02-23T00:00:00",
"db": "CNVD",
"id": "CNVD-2024-09314"
},
{
"date": "2024-02-13T00:00:00",
"db": "VULMON",
"id": "CVE-2023-48364"
},
{
"date": "2024-02-13T09:15:45.980000",
"db": "NVD",
"id": "CVE-2023-48364"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2024-02-21T00:00:00",
"db": "CNVD",
"id": "CNVD-2024-09314"
},
{
"date": "2024-02-13T00:00:00",
"db": "VULMON",
"id": "CVE-2023-48364"
},
{
"date": "2024-06-11T12:15:13.600000",
"db": "NVD",
"id": "CVE-2023-48364"
}
]
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Null pointer dereference vulnerability (CNVD-2024-09314) in multiple Siemens products",
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-09314"
}
],
"trust": 0.6
}
}
VAR-202405-0210
Vulnerability from variot - Updated: 2024-05-31 19:15A vulnerability has been identified in S7-PCT (All versions), Security Configuration Tool (SCT) (All versions), SIMATIC Automation Tool (All versions), SIMATIC BATCH V9.1 (All versions), SIMATIC NET PC Software (All versions), SIMATIC PCS 7 V9.1 (All versions), SIMATIC PDM V9.2 (All versions), SIMATIC Route Control V9.1 (All versions), SIMATIC STEP 7 V5 (All versions), SIMATIC WinCC OA V3.17 (All versions), SIMATIC WinCC OA V3.18 (All versions < V3.18 P025), SIMATIC WinCC OA V3.19 (All versions < V3.19 P010), SIMATIC WinCC Runtime Advanced (All versions), SIMATIC WinCC Runtime Professional V16 (All versions), SIMATIC WinCC Runtime Professional V17 (All versions), SIMATIC WinCC Runtime Professional V18 (All versions), SIMATIC WinCC Runtime Professional V19 (All versions), SIMATIC WinCC Unified PC Runtime (All versions), SIMATIC WinCC V7.4 (All versions), SIMATIC WinCC V7.5 (All versions), SIMATIC WinCC V8.0 (All versions), SINAMICS Startdrive (All versions < V19 SP1), SINUMERIK ONE virtual (All versions < V6.23), SINUMERIK PLC Programming Tool (All versions), TIA Portal Cloud Connector (All versions < V2.0), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions), Totally Integrated Automation Portal (TIA Portal) V18 (All versions), Totally Integrated Automation Portal (TIA Portal) V19 (All versions < V19 Update 2). The affected applications contain an out of bounds read vulnerability. This could allow an attacker to cause a Blue Screen of Death (BSOD) crash of the underlying Windows kernel. S7 PCT (Port Configuration Tool) is a PC-based software for parameterizing Siemens IO-Link master modules and third-party IO-Link devices. Security Configuration Tool (SCT) is an engineering software for safety devices such as SCALANCE-S or CP 443-1Advanced. SIMATIC Automation Tool allows commissioning, adjustment and service in combination with S7-1200 and S7-1500 controllers without an engineering framework. SIMATIC NET PC software is a separately sold software product for implementing communication products for SIMATIC.NET. SIMATIC PCS 7 is a distributed control system (DCS) that integrates SIMATIC WinCC, SIMATIC Batch, SIMATIC Route control, OpenPCS 7 and other components. SIMATIC PDM (Process Device Manager) is a universal, manufacturer-independent tool for configuration, parameter assignment, commissioning, diagnostics and maintenance of intelligent process devices (actuators, sensors) and automation components (remote I/O, multiplexers, process control units, compact controllers). SIMATIC STEP 7 V5 is the classic engineering software for configuring and programming SIMATIC S7-300/S7-400/C7/WinAC controllers. SIMATIC WinCC is a Supervisory Control and Data Acquisition (SCADA) system. SIMATIC WinCC Open Architecture (OA) is part of the SIMATIC HMI family. It is designed for applications that require a high degree of customer-specific adaptability, large or complex applications, and projects that impose specific system requirements or functions. SIMATIC WinCC Runtime Advanced is a visualization runtime platform for operator control and monitoring of machines and plants. SIMATIC WinCC Runtime Professional is a visualization runtime platform for operator control and monitoring of machines and plants. SIMATIC WinCC Unified PC Runtime is a new visualization runtime platform for operator control and monitoring of machines and plants. SINAMICS Startdrive commissioning software is the engineering tool for integrating SINAMICS drives in the TIA Portal. SINUMERIK CNC provides automation solutions for workshops, shop floors and large serial production environments. SINUMERIK ONE is a digital native CNC system. Totally Integrated Automation Portal (TIA Portal) is a PC software that provides the complete range of Siemens digital automation services, from digital planning and integrated engineering to transparent operation. TIA Portal Cloud Connector enables access to local PG/PC interfaces and connected SIMATIC hardware from TIA Portal Engineering when engineering via remote desktop on a private cloud server
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202405-0210",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "security configuration tool",
"scope": null,
"trust": 0.6,
"vendor": "siemens",
"version": null
},
{
"model": "simatic automation tool",
"scope": null,
"trust": 0.6,
"vendor": "siemens",
"version": null
},
{
"model": "simatic net pc software",
"scope": null,
"trust": 0.6,
"vendor": "siemens",
"version": null
},
{
"model": "simatic wincc runtime advanced",
"scope": null,
"trust": 0.6,
"vendor": "siemens",
"version": null
},
{
"model": "simatic wincc oa",
"scope": "eq",
"trust": 0.6,
"vendor": "siemens",
"version": "v3.17"
},
{
"model": "totally integrated automation portal",
"scope": "eq",
"trust": 0.6,
"vendor": "siemens",
"version": "v16"
},
{
"model": "totally integrated automation portal",
"scope": "eq",
"trust": 0.6,
"vendor": "siemens",
"version": "v17"
},
{
"model": "totally integrated automation portal",
"scope": "eq",
"trust": 0.6,
"vendor": "siemens",
"version": "v18"
},
{
"model": "totally integrated automation portal",
"scope": "eq",
"trust": 0.6,
"vendor": "siemens",
"version": "v15.1"
},
{
"model": "simatic pcs",
"scope": "eq",
"trust": 0.6,
"vendor": "siemens",
"version": "7v9.1"
},
{
"model": "simatic wincc runtime professional",
"scope": "eq",
"trust": 0.6,
"vendor": "siemens",
"version": "v17"
},
{
"model": "simatic wincc runtime professional",
"scope": "eq",
"trust": 0.6,
"vendor": "siemens",
"version": "v18"
},
{
"model": "simatic wincc runtime professional",
"scope": "eq",
"trust": 0.6,
"vendor": "siemens",
"version": "v19"
},
{
"model": "simatic wincc",
"scope": "eq",
"trust": 0.6,
"vendor": "siemens",
"version": "v8.0"
},
{
"model": "totally integrated automation portal update",
"scope": "eq",
"trust": 0.6,
"vendor": "siemens",
"version": "v19\u003cv192"
},
{
"model": "tia portal cloud connector",
"scope": "lt",
"trust": 0.6,
"vendor": "siemens",
"version": "v2.0"
},
{
"model": "sinumerik plc programming tool",
"scope": null,
"trust": 0.6,
"vendor": "siemens",
"version": null
},
{
"model": "sinumerik one virtual",
"scope": "lt",
"trust": 0.6,
"vendor": "siemens",
"version": "v6.23"
},
{
"model": "sinamics startdrive sp1",
"scope": "lt",
"trust": 0.6,
"vendor": "siemens",
"version": "v19"
},
{
"model": "simatic wincc",
"scope": "eq",
"trust": 0.6,
"vendor": "siemens",
"version": "v7.5"
},
{
"model": "simatic wincc",
"scope": "eq",
"trust": 0.6,
"vendor": "siemens",
"version": "v7.4"
},
{
"model": "simatic wincc unified pc runtime",
"scope": null,
"trust": 0.6,
"vendor": "siemens",
"version": null
},
{
"model": "simatic wincc runtime professional",
"scope": "eq",
"trust": 0.6,
"vendor": "siemens",
"version": "v16"
},
{
"model": "simatic wincc oa p010",
"scope": "eq",
"trust": 0.6,
"vendor": "siemens",
"version": "v3.19\u003cv3.19"
},
{
"model": "simatic wincc oa p025",
"scope": "eq",
"trust": 0.6,
"vendor": "siemens",
"version": "v3.18\u003cv3.18"
},
{
"model": "simatic step",
"scope": "eq",
"trust": 0.6,
"vendor": "siemens",
"version": "7v5"
},
{
"model": "simatic route control",
"scope": "eq",
"trust": 0.6,
"vendor": "siemens",
"version": "v9.1"
},
{
"model": "simatic pdm",
"scope": "eq",
"trust": 0.6,
"vendor": "siemens",
"version": "v9.2"
},
{
"model": "simatic batch",
"scope": "eq",
"trust": 0.6,
"vendor": "siemens",
"version": "v9.1"
},
{
"model": "s7-pct",
"scope": null,
"trust": 0.6,
"vendor": "siemens",
"version": null
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-24524"
}
]
},
"cve": "CVE-2023-46280",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "LOCAL",
"authentication": "SINGLE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 4.6,
"confidentialityImpact": "NONE",
"exploitabilityScore": 3.1,
"id": "CNVD-2024-24524",
"impactScore": 6.9,
"integrityImpact": "NONE",
"severity": "MEDIUM",
"trust": 0.6,
"vectorString": "AV:L/AC:L/Au:S/C:N/I:N/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"author": "productcert@siemens.com",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"exploitabilityScore": 2.0,
"impactScore": 4.0,
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:N/I:N/A:H",
"version": "3.1"
}
],
"severity": [
{
"author": "productcert@siemens.com",
"id": "CVE-2023-46280",
"trust": 1.0,
"value": "MEDIUM"
},
{
"author": "CNVD",
"id": "CNVD-2024-24524",
"trust": 0.6,
"value": "MEDIUM"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-24524"
},
{
"db": "NVD",
"id": "CVE-2023-46280"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "A vulnerability has been identified in S7-PCT (All versions), Security Configuration Tool (SCT) (All versions), SIMATIC Automation Tool (All versions), SIMATIC BATCH V9.1 (All versions), SIMATIC NET PC Software (All versions), SIMATIC PCS 7 V9.1 (All versions), SIMATIC PDM V9.2 (All versions), SIMATIC Route Control V9.1 (All versions), SIMATIC STEP 7 V5 (All versions), SIMATIC WinCC OA V3.17 (All versions), SIMATIC WinCC OA V3.18 (All versions \u003c V3.18 P025), SIMATIC WinCC OA V3.19 (All versions \u003c V3.19 P010), SIMATIC WinCC Runtime Advanced (All versions), SIMATIC WinCC Runtime Professional V16 (All versions), SIMATIC WinCC Runtime Professional V17 (All versions), SIMATIC WinCC Runtime Professional V18 (All versions), SIMATIC WinCC Runtime Professional V19 (All versions), SIMATIC WinCC Unified PC Runtime (All versions), SIMATIC WinCC V7.4 (All versions), SIMATIC WinCC V7.5 (All versions), SIMATIC WinCC V8.0 (All versions), SINAMICS Startdrive (All versions \u003c V19 SP1), SINUMERIK ONE virtual (All versions \u003c V6.23), SINUMERIK PLC Programming Tool (All versions), TIA Portal Cloud Connector (All versions \u003c V2.0), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions), Totally Integrated Automation Portal (TIA Portal) V18 (All versions), Totally Integrated Automation Portal (TIA Portal) V19 (All versions \u003c V19 Update 2). The affected applications contain an out of bounds read vulnerability. This could allow an attacker to cause a Blue Screen of Death (BSOD) crash of the underlying Windows kernel. S7 PCT (Port Configuration Tool) is a PC-based software for parameterizing Siemens IO-Link master modules and third-party IO-Link devices. Security Configuration Tool (SCT) is an engineering software for safety devices such as SCALANCE-S or CP 443-1Advanced. SIMATIC Automation Tool allows commissioning, adjustment and service in combination with S7-1200 and S7-1500 controllers without an engineering framework. SIMATIC NET PC software is a separately sold software product for implementing communication products for SIMATIC.NET. SIMATIC PCS 7 is a distributed control system (DCS) that integrates SIMATIC WinCC, SIMATIC Batch, SIMATIC Route control, OpenPCS 7 and other components. SIMATIC PDM (Process Device Manager) is a universal, manufacturer-independent tool for configuration, parameter assignment, commissioning, diagnostics and maintenance of intelligent process devices (actuators, sensors) and automation components (remote I/O, multiplexers, process control units, compact controllers). SIMATIC STEP 7 V5 is the classic engineering software for configuring and programming SIMATIC S7-300/S7-400/C7/WinAC controllers. SIMATIC WinCC is a Supervisory Control and Data Acquisition (SCADA) system. SIMATIC WinCC Open Architecture (OA) is part of the SIMATIC HMI family. It is designed for applications that require a high degree of customer-specific adaptability, large or complex applications, and projects that impose specific system requirements or functions. SIMATIC WinCC Runtime Advanced is a visualization runtime platform for operator control and monitoring of machines and plants. SIMATIC WinCC Runtime Professional is a visualization runtime platform for operator control and monitoring of machines and plants. SIMATIC WinCC Unified PC Runtime is a new visualization runtime platform for operator control and monitoring of machines and plants. SINAMICS Startdrive commissioning software is the engineering tool for integrating SINAMICS drives in the TIA Portal. SINUMERIK CNC provides automation solutions for workshops, shop floors and large serial production environments. SINUMERIK ONE is a digital native CNC system. Totally Integrated Automation Portal (TIA Portal) is a PC software that provides the complete range of Siemens digital automation services, from digital planning and integrated engineering to transparent operation. TIA Portal Cloud Connector enables access to local PG/PC interfaces and connected SIMATIC hardware from TIA Portal Engineering when engineering via remote desktop on a private cloud server",
"sources": [
{
"db": "NVD",
"id": "CVE-2023-46280"
},
{
"db": "CNVD",
"id": "CNVD-2024-24524"
}
],
"trust": 1.44
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "SIEMENS",
"id": "SSA-962515",
"trust": 1.6
},
{
"db": "NVD",
"id": "CVE-2023-46280",
"trust": 1.6
},
{
"db": "CNVD",
"id": "CNVD-2024-24524",
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-24524"
},
{
"db": "NVD",
"id": "CVE-2023-46280"
}
]
},
"id": "VAR-202405-0210",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-24524"
}
],
"trust": 1.1959388363636363
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"ICS"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-24524"
}
]
},
"last_update_date": "2024-05-31T19:15:21.586000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Patch for Siemens Industrial Products Out-of-Bounds Read Vulnerability",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchinfo/show/547666"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-24524"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-125",
"trust": 1.0
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2023-46280"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.6,
"url": "https://cert-portal.siemens.com/productcert/html/ssa-962515.html"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-24524"
},
{
"db": "NVD",
"id": "CVE-2023-46280"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2024-24524"
},
{
"db": "NVD",
"id": "CVE-2023-46280"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2024-05-30T00:00:00",
"db": "CNVD",
"id": "CNVD-2024-24524"
},
{
"date": "2024-05-14T16:15:40.800000",
"db": "NVD",
"id": "CVE-2023-46280"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2024-05-28T00:00:00",
"db": "CNVD",
"id": "CNVD-2024-24524"
},
{
"date": "2024-05-14T19:18:31.490000",
"db": "NVD",
"id": "CVE-2023-46280"
}
]
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Siemens Industrial Products Out-of-Bounds Read Vulnerability",
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-24524"
}
],
"trust": 0.6
}
}
VAR-202404-0165
Vulnerability from variot - Updated: 2024-04-20 23:23SIMATIC PCS 7 is a process control system. SIMATIC WinCC is an automated supervisory control and data acquisition (SCADA) system. SIMATIC WinCC Runtime Professional is a visualization runtime platform for operators to control and monitor machines and equipment.
Siemens SIMATIC WinCC has a denial of service vulnerability, which is caused by the affected product failing to properly validate the input provided in the login dialog box. An attacker could exploit this vulnerability to cause a denial of service.
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202404-0165",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "simatic pcs sp2 uc04",
"scope": "eq",
"trust": 0.6,
"vendor": "siemens",
"version": "7v9.1\u003cv9.1"
},
{
"model": "simatic wincc runtime professional",
"scope": "eq",
"trust": 0.6,
"vendor": "siemens",
"version": "v17"
},
{
"model": "simatic wincc runtime professional",
"scope": "eq",
"trust": 0.6,
"vendor": "siemens",
"version": "v18"
},
{
"model": "simatic wincc runtime professional",
"scope": "eq",
"trust": 0.6,
"vendor": "siemens",
"version": "v19"
},
{
"model": "simatic wincc sp2 update",
"scope": "eq",
"trust": 0.6,
"vendor": "siemens",
"version": "v7.5\u003cv7.516"
},
{
"model": "simatic wincc",
"scope": "eq",
"trust": 0.6,
"vendor": "siemens",
"version": "v8.0"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-17302"
}
]
},
"cve": "CVE-2023-50821",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "LOCAL",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 4.9,
"confidentialityImpact": "NONE",
"exploitabilityScore": 3.9,
"id": "CNVD-2024-17302",
"impactScore": 6.9,
"integrityImpact": "NONE",
"severity": "MEDIUM",
"trust": 0.6,
"vectorString": "AV:L/AC:L/Au:N/C:N/I:N/A:C",
"version": "2.0"
}
],
"cvssV3": [],
"severity": [
{
"author": "CNVD",
"id": "CNVD-2024-17302",
"trust": 0.6,
"value": "MEDIUM"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-17302"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "SIMATIC PCS 7 is a process control system. SIMATIC WinCC is an automated supervisory control and data acquisition (SCADA) system. SIMATIC WinCC Runtime Professional is a visualization runtime platform for operators to control and monitor machines and equipment.\n\nSiemens SIMATIC WinCC has a denial of service vulnerability, which is caused by the affected product failing to properly validate the input provided in the login dialog box. An attacker could exploit this vulnerability to cause a denial of service.",
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-17302"
}
],
"trust": 0.6
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "SIEMENS",
"id": "SSA-730482",
"trust": 0.6
},
{
"db": "NVD",
"id": "CVE-2023-50821",
"trust": 0.6
},
{
"db": "CNVD",
"id": "CNVD-2024-17302",
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-17302"
}
]
},
"id": "VAR-202404-0165",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-17302"
}
],
"trust": 1.2521127766666666
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"ICS"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-17302"
}
]
},
"last_update_date": "2024-04-20T23:23:18.968000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Patch for Siemens SIMATIC WinCC Denial of Service Vulnerability (CNVD-2024-17302)",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchinfo/show/540266"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-17302"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 0.6,
"url": "https://cert-portal.siemens.com/productcert/html/ssa-730482.html"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-17302"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2024-17302"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2024-04-10T00:00:00",
"db": "CNVD",
"id": "CNVD-2024-17302"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2024-04-10T00:00:00",
"db": "CNVD",
"id": "CNVD-2024-17302"
}
]
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Siemens SIMATIC WinCC Denial of Service Vulnerability (CNVD-2024-17302)",
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-17302"
}
],
"trust": 0.6
}
}
VAR-201007-0198
Vulnerability from variot - Updated: 2024-03-01 22:55Siemens Simatic WinCC and PCS 7 SCADA system uses a hard-coded password, which allows local users to access a back-end database and gain privileges, as demonstrated in the wild in July 2010 by the Stuxnet worm, a different vulnerability than CVE-2010-2568. Siemens SIMATIC WinCC is a multi-user system that provides complete monitoring and data acquisition (SCADA) functionality for the industrial sector, from single-user systems to redundant server and remote web client solutions. The Siemens SIMATIC WinCC data uses the built-in user name and password and does not inform the user that it needs to be modified. An attacker can use this information to read database data or inject code into a database. Siemens SIMATIC WinCC is affected by a vulnerability that allows attackers to bypass security. Successfully exploiting this issue may lead to further attacks. ----------------------------------------------------------------------
"From 2007 to 2009 vulnerabilities in a typical end-user PC almost doubled from about 220 to 420."
Non-Microsoft software to blame for increase in vulnerabilities affecting typical Windows end-users, read more:
http://secunia.com/gfx/pdf/Secunia_Half_Year_Report_2010.pdf
TITLE: Siemens SIMATIC WinCC Undocumented Database User Account
SECUNIA ADVISORY ID: SA40682
VERIFY ADVISORY: Secunia.com http://secunia.com/advisories/40682/ Customer Area (Credentials Required) https://ca.secunia.com/?page=viewadvisory&vuln_id=40682
RELEASE DATE: 2010-07-24
DISCUSS ADVISORY: http://secunia.com/advisories/40682/#comments
AVAILABLE ON SITE AND IN CUSTOMER AREA: * Last Update * Popularity * Comments * Criticality Level * Impact * Where * Solution Status * Operating System / Software * CVE Reference(s)
http://secunia.com/advisories/40682/
ONLY AVAILABLE IN CUSTOMER AREA: * Authentication Level * Report Reliability * Secunia PoC * Secunia Analysis * Systems Affected * Approve Distribution * Remediation Status * Secunia CVSS Score * CVSS
https://ca.secunia.com/?page=viewadvisory&vuln_id=40682
ONLY AVAILABLE WITH SECUNIA CSI AND SECUNIA PSI: * AUTOMATED SCANNING
http://secunia.com/vulnerability_scanning/personal/ http://secunia.com/vulnerability_scanning/corporate/wsus_sccm_3rd_third_party_patching/
DESCRIPTION: A security issue has been reported in Siemens SIMATIC WinCC, which can be exploited by malicious people to gain unauthorised access.
SOLUTION: Restrict network access to the database to trusted users only.
PROVIDED AND/OR DISCOVERED BY: Discovered in the wild.
ORIGINAL ADVISORY: http://www.wilderssecurity.com/showpost.php?p=1712134&postcount=22 http://www.f-secure.com/weblog/archives/00001987.html
OTHER REFERENCES: Further details available in Customer Area: http://secunia.com/products/corporate/EVM/
DEEP LINKS: Further details available in Customer Area: http://secunia.com/products/corporate/EVM/
EXTENDED DESCRIPTION: Further details available in Customer Area: http://secunia.com/products/corporate/EVM/
EXTENDED SOLUTION: Further details available in Customer Area: http://secunia.com/products/corporate/EVM/
EXPLOIT: Further details available in Customer Area: http://secunia.com/products/corporate/EVM/
About: This Advisory was delivered by Secunia as a free service to help private users keeping their systems up to date against the latest vulnerabilities.
Subscribe: http://secunia.com/advisories/secunia_security_advisories/
Definitions: (Criticality, Where etc.) http://secunia.com/advisories/about_secunia_advisories/
Please Note: Secunia recommends that you verify all advisories you receive by clicking the link. Secunia NEVER sends attached files with advisories. Secunia does not advise people to install third party patches, only use those supplied by the vendor.
Unsubscribe: Secunia Security Advisories http://secunia.com/sec_adv_unsubscribe/?email=packet%40packetstormsecurity.org
Show details on source website
{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-201007-0198",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "simatic wincc",
"scope": "eq",
"trust": 2.5,
"vendor": "siemens",
"version": "6.2"
},
{
"model": "simatic pcs 7",
"scope": "eq",
"trust": 1.6,
"vendor": "siemens",
"version": "6.0"
},
{
"model": "simatic pcs 7",
"scope": "eq",
"trust": 1.6,
"vendor": "siemens",
"version": "6.1"
},
{
"model": "simatic pcs 7",
"scope": "eq",
"trust": 1.6,
"vendor": "siemens",
"version": "7.1"
},
{
"model": "simatic wincc",
"scope": "eq",
"trust": 1.6,
"vendor": "siemens",
"version": "7.0"
},
{
"model": "simatic pcs 7",
"scope": "eq",
"trust": 1.6,
"vendor": "siemens",
"version": "7.0"
},
{
"model": null,
"scope": "eq",
"trust": 1.2,
"vendor": "simatic pcs 7",
"version": "7.0"
},
{
"model": null,
"scope": "eq",
"trust": 1.2,
"vendor": "simatic pcs 7",
"version": "7.1"
},
{
"model": "simatic wincc",
"scope": null,
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": null
},
{
"model": "simatic pcs 7",
"scope": null,
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": null
},
{
"model": null,
"scope": "eq",
"trust": 0.6,
"vendor": "simatic wincc",
"version": "*"
},
{
"model": null,
"scope": "eq",
"trust": 0.6,
"vendor": "simatic wincc",
"version": "6.2"
},
{
"model": null,
"scope": "eq",
"trust": 0.6,
"vendor": "simatic wincc",
"version": "7.0"
},
{
"model": null,
"scope": "eq",
"trust": 0.6,
"vendor": "simatic pcs 7",
"version": "*"
},
{
"model": null,
"scope": "eq",
"trust": 0.6,
"vendor": "simatic pcs 7",
"version": "6.0"
},
{
"model": null,
"scope": "eq",
"trust": 0.6,
"vendor": "simatic pcs 7",
"version": "6.1"
},
{
"model": "simatic wincc",
"scope": null,
"trust": 0.6,
"vendor": "siemens",
"version": null
},
{
"model": "simatic pcs 7",
"scope": null,
"trust": 0.6,
"vendor": "siemens",
"version": null
},
{
"model": "simatic wincc",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "0"
}
],
"sources": [
{
"db": "IVD",
"id": "06a89dde-2356-11e6-abef-000c29c66e3d"
},
{
"db": "IVD",
"id": "7d70cfdf-463f-11e9-ad83-000c29342cb1"
},
{
"db": "IVD",
"id": "407e95f0-1fb3-11e6-abef-000c29c66e3d"
},
{
"db": "CNVD",
"id": "CNVD-2010-1369"
},
{
"db": "BID",
"id": "41753"
},
{
"db": "JVNDB",
"id": "JVNDB-2010-001829"
},
{
"db": "CNNVD",
"id": "CNNVD-201007-241"
},
{
"db": "NVD",
"id": "CVE-2010-2772"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:a:siemens:simatic_wincc:6.2:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:simatic_wincc:7.0:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:simatic_wincc:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:a:siemens:simatic_pcs_7:7.0:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:simatic_pcs_7:7.0:sp1:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:simatic_pcs_7:6.1:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:simatic_pcs_7:6.0:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:simatic_pcs_7:7.1:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:simatic_pcs_7:7.1:sp1:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:simatic_pcs_7:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2010-2772"
}
]
},
"credits": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/credits#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Siemens",
"sources": [
{
"db": "BID",
"id": "41753"
}
],
"trust": 0.3
},
"cve": "CVE-2010-2772",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"acInsufInfo": false,
"accessComplexity": "MEDIUM",
"accessVector": "LOCAL",
"authentication": "NONE",
"author": "NVD",
"availabilityImpact": "COMPLETE",
"baseScore": 6.9,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 3.4,
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"obtainAllPrivilege": true,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "MEDIUM",
"trust": 1.0,
"userInteractionRequired": true,
"vectorString": "AV:L/AC:M/Au:N/C:C/I:C/A:C",
"version": "2.0"
},
{
"acInsufInfo": null,
"accessComplexity": "Medium",
"accessVector": "Local",
"authentication": "None",
"author": "NVD",
"availabilityImpact": "Complete",
"baseScore": 6.9,
"confidentialityImpact": "Complete",
"exploitabilityScore": null,
"id": "CVE-2010-2772",
"impactScore": null,
"integrityImpact": "Complete",
"obtainAllPrivilege": null,
"obtainOtherPrivilege": null,
"obtainUserPrivilege": null,
"severity": "Medium",
"trust": 0.9,
"userInteractionRequired": null,
"vectorString": "AV:L/AC:M/Au:N/C:C/I:C/A:C",
"version": "2.0"
},
{
"accessComplexity": "MEDIUM",
"accessVector": "LOCAL",
"authentication": "NONE",
"author": "IVD",
"availabilityImpact": "COMPLETE",
"baseScore": 6.9,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 3.4,
"id": "06a89dde-2356-11e6-abef-000c29c66e3d",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "MEDIUM",
"trust": 0.2,
"vectorString": "AV:L/AC:M/Au:N/C:C/I:C/A:C",
"version": "2.9 [IVD]"
},
{
"accessComplexity": "MEDIUM",
"accessVector": "LOCAL",
"authentication": "NONE",
"author": "IVD",
"availabilityImpact": "COMPLETE",
"baseScore": 6.9,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 3.4,
"id": "7d70cfdf-463f-11e9-ad83-000c29342cb1",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "MEDIUM",
"trust": 0.2,
"vectorString": "AV:L/AC:M/Au:N/C:C/I:C/A:C",
"version": "2.9 [IVD]"
},
{
"accessComplexity": "MEDIUM",
"accessVector": "LOCAL",
"authentication": "NONE",
"author": "IVD",
"availabilityImpact": "COMPLETE",
"baseScore": 6.9,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 3.4,
"id": "407e95f0-1fb3-11e6-abef-000c29c66e3d",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "MEDIUM",
"trust": 0.2,
"vectorString": "AV:L/AC:M/Au:N/C:C/I:C/A:C",
"version": "2.9 [IVD]"
},
{
"accessComplexity": "MEDIUM",
"accessVector": "LOCAL",
"authentication": "NONE",
"author": "VULHUB",
"availabilityImpact": "COMPLETE",
"baseScore": 6.9,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 3.4,
"id": "VHN-45377",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "MEDIUM",
"trust": 0.1,
"vectorString": "AV:L/AC:M/AU:N/C:C/I:C/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"author": "NVD",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 1.8,
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Local",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 7.8,
"baseSeverity": "High",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "CVE-2010-2772",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "Low",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2010-2772",
"trust": 1.8,
"value": "HIGH"
},
{
"author": "CNNVD",
"id": "CNNVD-201007-241",
"trust": 0.6,
"value": "MEDIUM"
},
{
"author": "IVD",
"id": "06a89dde-2356-11e6-abef-000c29c66e3d",
"trust": 0.2,
"value": "MEDIUM"
},
{
"author": "IVD",
"id": "7d70cfdf-463f-11e9-ad83-000c29342cb1",
"trust": 0.2,
"value": "MEDIUM"
},
{
"author": "IVD",
"id": "407e95f0-1fb3-11e6-abef-000c29c66e3d",
"trust": 0.2,
"value": "MEDIUM"
},
{
"author": "VULHUB",
"id": "VHN-45377",
"trust": 0.1,
"value": "MEDIUM"
},
{
"author": "VULMON",
"id": "CVE-2010-2772",
"trust": 0.1,
"value": "MEDIUM"
}
]
}
],
"sources": [
{
"db": "IVD",
"id": "06a89dde-2356-11e6-abef-000c29c66e3d"
},
{
"db": "IVD",
"id": "7d70cfdf-463f-11e9-ad83-000c29342cb1"
},
{
"db": "IVD",
"id": "407e95f0-1fb3-11e6-abef-000c29c66e3d"
},
{
"db": "VULHUB",
"id": "VHN-45377"
},
{
"db": "VULMON",
"id": "CVE-2010-2772"
},
{
"db": "JVNDB",
"id": "JVNDB-2010-001829"
},
{
"db": "CNNVD",
"id": "CNNVD-201007-241"
},
{
"db": "NVD",
"id": "CVE-2010-2772"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Siemens Simatic WinCC and PCS 7 SCADA system uses a hard-coded password, which allows local users to access a back-end database and gain privileges, as demonstrated in the wild in July 2010 by the Stuxnet worm, a different vulnerability than CVE-2010-2568. Siemens SIMATIC WinCC is a multi-user system that provides complete monitoring and data acquisition (SCADA) functionality for the industrial sector, from single-user systems to redundant server and remote web client solutions. The Siemens SIMATIC WinCC data uses the built-in user name and password and does not inform the user that it needs to be modified. An attacker can use this information to read database data or inject code into a database. Siemens SIMATIC WinCC is affected by a vulnerability that allows attackers to bypass security. Successfully exploiting this issue may lead to further attacks. ----------------------------------------------------------------------\n\n\n\"From 2007 to 2009 vulnerabilities in a typical end-user PC almost doubled from about 220 to 420.\"\n\nNon-Microsoft software to blame for increase in vulnerabilities affecting typical Windows end-users, read more:\n\nhttp://secunia.com/gfx/pdf/Secunia_Half_Year_Report_2010.pdf\n\n\n----------------------------------------------------------------------\n\nTITLE:\nSiemens SIMATIC WinCC Undocumented Database User Account\n\nSECUNIA ADVISORY ID:\nSA40682\n\nVERIFY ADVISORY:\nSecunia.com\nhttp://secunia.com/advisories/40682/\nCustomer Area (Credentials Required)\nhttps://ca.secunia.com/?page=viewadvisory\u0026vuln_id=40682\n\nRELEASE DATE:\n2010-07-24\n\nDISCUSS ADVISORY:\nhttp://secunia.com/advisories/40682/#comments\n\nAVAILABLE ON SITE AND IN CUSTOMER AREA:\n * Last Update\n * Popularity\n * Comments\n * Criticality Level\n * Impact\n * Where\n * Solution Status\n * Operating System / Software\n * CVE Reference(s)\n\nhttp://secunia.com/advisories/40682/\n\nONLY AVAILABLE IN CUSTOMER AREA:\n * Authentication Level\n * Report Reliability\n * Secunia PoC\n * Secunia Analysis\n * Systems Affected\n * Approve Distribution\n * Remediation Status\n * Secunia CVSS Score\n * CVSS\n\nhttps://ca.secunia.com/?page=viewadvisory\u0026vuln_id=40682\n\nONLY AVAILABLE WITH SECUNIA CSI AND SECUNIA PSI:\n * AUTOMATED SCANNING\n\nhttp://secunia.com/vulnerability_scanning/personal/\nhttp://secunia.com/vulnerability_scanning/corporate/wsus_sccm_3rd_third_party_patching/\n\nDESCRIPTION:\nA security issue has been reported in Siemens SIMATIC WinCC, which\ncan be exploited by malicious people to gain unauthorised access. \n\nSOLUTION:\nRestrict network access to the database to trusted users only. \n\nPROVIDED AND/OR DISCOVERED BY:\nDiscovered in the wild. \n\nORIGINAL ADVISORY:\nhttp://www.wilderssecurity.com/showpost.php?p=1712134\u0026postcount=22\nhttp://www.f-secure.com/weblog/archives/00001987.html\n\nOTHER REFERENCES:\nFurther details available in Customer Area:\nhttp://secunia.com/products/corporate/EVM/\n\nDEEP LINKS:\nFurther details available in Customer Area:\nhttp://secunia.com/products/corporate/EVM/\n\nEXTENDED DESCRIPTION:\nFurther details available in Customer Area:\nhttp://secunia.com/products/corporate/EVM/\n\nEXTENDED SOLUTION:\nFurther details available in Customer Area:\nhttp://secunia.com/products/corporate/EVM/\n\nEXPLOIT:\nFurther details available in Customer Area:\nhttp://secunia.com/products/corporate/EVM/\n\n----------------------------------------------------------------------\n\nAbout:\nThis Advisory was delivered by Secunia as a free service to help\nprivate users keeping their systems up to date against the latest\nvulnerabilities. \n\nSubscribe:\nhttp://secunia.com/advisories/secunia_security_advisories/\n\nDefinitions: (Criticality, Where etc.)\nhttp://secunia.com/advisories/about_secunia_advisories/\n\n\nPlease Note:\nSecunia recommends that you verify all advisories you receive by\nclicking the link. \nSecunia NEVER sends attached files with advisories. \nSecunia does not advise people to install third party patches, only\nuse those supplied by the vendor. \n\n----------------------------------------------------------------------\n\nUnsubscribe: Secunia Security Advisories\nhttp://secunia.com/sec_adv_unsubscribe/?email=packet%40packetstormsecurity.org\n\n----------------------------------------------------------------------\n\n\n",
"sources": [
{
"db": "NVD",
"id": "CVE-2010-2772"
},
{
"db": "JVNDB",
"id": "JVNDB-2010-001829"
},
{
"db": "CNVD",
"id": "CNVD-2010-1369"
},
{
"db": "BID",
"id": "41753"
},
{
"db": "IVD",
"id": "06a89dde-2356-11e6-abef-000c29c66e3d"
},
{
"db": "IVD",
"id": "7d70cfdf-463f-11e9-ad83-000c29342cb1"
},
{
"db": "IVD",
"id": "407e95f0-1fb3-11e6-abef-000c29c66e3d"
},
{
"db": "VULHUB",
"id": "VHN-45377"
},
{
"db": "VULMON",
"id": "CVE-2010-2772"
},
{
"db": "PACKETSTORM",
"id": "92130"
}
],
"trust": 3.24
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2010-2772",
"trust": 4.3
},
{
"db": "BID",
"id": "41753",
"trust": 2.9
},
{
"db": "SECUNIA",
"id": "40682",
"trust": 2.1
},
{
"db": "ICS CERT",
"id": "ICSA-12-205-01",
"trust": 2.0
},
{
"db": "VUPEN",
"id": "ADV-2010-1893",
"trust": 1.9
},
{
"db": "CNNVD",
"id": "CNNVD-201007-241",
"trust": 1.3
},
{
"db": "CNVD",
"id": "CNVD-2010-1369",
"trust": 1.0
},
{
"db": "XF",
"id": "60587",
"trust": 0.8
},
{
"db": "JVNDB",
"id": "JVNDB-2010-001829",
"trust": 0.8
},
{
"db": "IVD",
"id": "06A89DDE-2356-11E6-ABEF-000C29C66E3D",
"trust": 0.2
},
{
"db": "IVD",
"id": "7D70CFDF-463F-11E9-AD83-000C29342CB1",
"trust": 0.2
},
{
"db": "IVD",
"id": "407E95F0-1FB3-11E6-ABEF-000C29C66E3D",
"trust": 0.2
},
{
"db": "VULHUB",
"id": "VHN-45377",
"trust": 0.1
},
{
"db": "VUPEN",
"id": "2010/1893",
"trust": 0.1
},
{
"db": "VULMON",
"id": "CVE-2010-2772",
"trust": 0.1
},
{
"db": "PACKETSTORM",
"id": "92130",
"trust": 0.1
}
],
"sources": [
{
"db": "IVD",
"id": "06a89dde-2356-11e6-abef-000c29c66e3d"
},
{
"db": "IVD",
"id": "7d70cfdf-463f-11e9-ad83-000c29342cb1"
},
{
"db": "IVD",
"id": "407e95f0-1fb3-11e6-abef-000c29c66e3d"
},
{
"db": "CNVD",
"id": "CNVD-2010-1369"
},
{
"db": "VULHUB",
"id": "VHN-45377"
},
{
"db": "VULMON",
"id": "CVE-2010-2772"
},
{
"db": "BID",
"id": "41753"
},
{
"db": "JVNDB",
"id": "JVNDB-2010-001829"
},
{
"db": "PACKETSTORM",
"id": "92130"
},
{
"db": "CNNVD",
"id": "CNNVD-201007-241"
},
{
"db": "NVD",
"id": "CVE-2010-2772"
}
]
},
"id": "VAR-201007-0198",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "IVD",
"id": "06a89dde-2356-11e6-abef-000c29c66e3d"
},
{
"db": "IVD",
"id": "7d70cfdf-463f-11e9-ad83-000c29342cb1"
},
{
"db": "IVD",
"id": "407e95f0-1fb3-11e6-abef-000c29c66e3d"
},
{
"db": "CNVD",
"id": "CNVD-2010-1369"
},
{
"db": "VULHUB",
"id": "VHN-45377"
}
],
"trust": 1.909197615
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"ICS"
],
"sub_category": null,
"trust": 1.2
}
],
"sources": [
{
"db": "IVD",
"id": "06a89dde-2356-11e6-abef-000c29c66e3d"
},
{
"db": "IVD",
"id": "7d70cfdf-463f-11e9-ad83-000c29342cb1"
},
{
"db": "IVD",
"id": "407e95f0-1fb3-11e6-abef-000c29c66e3d"
},
{
"db": "CNVD",
"id": "CNVD-2010-1369"
}
]
},
"last_update_date": "2024-03-01T22:55:17.916000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Product\u00a0Support",
"trust": 0.8,
"url": "http://support.automation.siemens.com/ww/llisapi.dll?func=cslib.csinfo\u0026aktprim=0\u0026siteid=cseus\u0026lang=en\u0026siteid=cseus\u0026groupid=4000003\u0026groupid=4000003\u0026groupid=4000003\u0026extranet=standard\u0026viewreg=ww\u0026nodeid0=10805583"
},
{
"title": "Siemens SIMATIC WinCC default password security bypass vulnerability patch",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchinfo/show/81338"
},
{
"title": "win32-stuxnet",
"trust": 0.1,
"url": "https://github.com/uraninite/win32-stuxnet "
},
{
"title": "welivesecurity",
"trust": 0.1,
"url": "https://www.welivesecurity.com/2016/06/07/infrastructure-attacks-next-generation/"
},
{
"title": "Threatpost",
"trust": 0.1,
"url": "https://threatpost.com/kelihos-update-includes-new-tld-and-usb-infection-capabilities-121112/77299/"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2010-1369"
},
{
"db": "VULMON",
"id": "CVE-2010-2772"
},
{
"db": "JVNDB",
"id": "JVNDB-2010-001829"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-798",
"trust": 1.0
},
{
"problemtype": "Use hard-coded credentials (CWE-798) [NVD evaluation ]",
"trust": 0.8
},
{
"problemtype": "CWE-255",
"trust": 0.1
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-45377"
},
{
"db": "JVNDB",
"id": "JVNDB-2010-001829"
},
{
"db": "NVD",
"id": "CVE-2010-2772"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.0,
"url": "http://www.securityfocus.com/bid/41753"
},
{
"trust": 2.0,
"url": "http://ics-cert.us-cert.gov/advisories/icsa-12-205-01"
},
{
"trust": 2.0,
"url": "http://secunia.com/advisories/40682"
},
{
"trust": 2.0,
"url": "http://www.vupen.com/english/advisories/2010/1893"
},
{
"trust": 1.8,
"url": "http://www.sea.siemens.com/us/news/industrial/pages/wincc_update.aspx"
},
{
"trust": 1.8,
"url": "http://infoworld.com/d/security-central/new-weaponized-virus-targets-industrial-secrets-725"
},
{
"trust": 1.8,
"url": "http://infoworld.com/d/security-central/siemens-warns-users-dont-change-passwords-after-worm-attack-915?sourcefssr"
},
{
"trust": 1.8,
"url": "http://krebsonsecurity.com/2010/07/experts-warn-of-new-windows-shortcut-flaw/"
},
{
"trust": 1.8,
"url": "http://www.wired.com/threatlevel/2010/07/siemens-scada/"
},
{
"trust": 1.7,
"url": "http://www.automation.siemens.com/forum/guests/postshow.aspx?postid=16127\u002616127\u0026language=en\u0026pageindex=1"
},
{
"trust": 1.4,
"url": "http://support.automation.siemens.com/ww/llisapi.dll?func=cslib.csinfo\u0026lang=en\u0026objid=43876783\u0026caller=viewhttp://support.automation.siemens.com/ww/llisapi.dll?func=cslib.csinfo\u0026lang=en\u0026objid=43876783\u0026c"
},
{
"trust": 1.3,
"url": "http://www.f-secure.com/weblog/archives/00001987.html"
},
{
"trust": 1.2,
"url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/60587"
},
{
"trust": 1.2,
"url": "http://www.wilderssecurity.com/showpost.php?p=1712134\u0026postcount=22"
},
{
"trust": 0.8,
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnid=cve-2010-2772"
},
{
"trust": 0.8,
"url": "http://xforce.iss.net/xforce/xfdb/60587"
},
{
"trust": 0.6,
"url": "http://it.slashdot.org/comments.pl?sid=1721020"
},
{
"trust": 0.3,
"url": "http://it.slashdot.org/comments.pl?sid=1721020\u0026cid=32920758"
},
{
"trust": 0.3,
"url": "http://aunz.siemens.com/newscentre/productreleases/pages/iac_pr_simaticwinccv62.aspx"
},
{
"trust": 0.3,
"url": "https://www.automation.siemens.com/forum/guests/postshow.aspx?postid=16127\u0026language=en\u0026pageindex=2"
},
{
"trust": 0.1,
"url": "http://support.automation.siemens.com/ww/llisapi.dll?func=cslib.csinfo\u0026amp;lang=en\u0026amp;objid=43876783\u0026amp;caller=viewhttp://support.automation.siemens.com/ww/llisapi.dll?func=cslib.csinfo\u0026amp;lang=en\u0026amp;objid=43876783\u0026amp;c"
},
{
"trust": 0.1,
"url": "http://www.automation.siemens.com/forum/guests/postshow.aspx?postid=16127\u0026amp;16127\u0026amp;language=en\u0026amp;pageindex=1"
},
{
"trust": 0.1,
"url": "http://www.wilderssecurity.com/showpost.php?p=1712134\u0026amp;postcount=22"
},
{
"trust": 0.1,
"url": "https://cwe.mitre.org/data/definitions/255.html"
},
{
"trust": 0.1,
"url": "https://github.com/uraninite/win32-stuxnet"
},
{
"trust": 0.1,
"url": "http://tools.cisco.com/security/center/viewalert.x?alertid=20969"
},
{
"trust": 0.1,
"url": "https://nvd.nist.gov"
},
{
"trust": 0.1,
"url": "https://threatpost.com/kelihos-update-includes-new-tld-and-usb-infection-capabilities-121112/77299/"
},
{
"trust": 0.1,
"url": "https://ca.secunia.com/?page=viewadvisory\u0026vuln_id=40682"
},
{
"trust": 0.1,
"url": "http://secunia.com/products/corporate/evm/"
},
{
"trust": 0.1,
"url": "http://secunia.com/advisories/secunia_security_advisories/"
},
{
"trust": 0.1,
"url": "http://secunia.com/vulnerability_scanning/corporate/wsus_sccm_3rd_third_party_patching/"
},
{
"trust": 0.1,
"url": "http://secunia.com/advisories/40682/#comments"
},
{
"trust": 0.1,
"url": "http://secunia.com/vulnerability_scanning/personal/"
},
{
"trust": 0.1,
"url": "http://secunia.com/advisories/40682/"
},
{
"trust": 0.1,
"url": "http://secunia.com/sec_adv_unsubscribe/?email=packet%40packetstormsecurity.org"
},
{
"trust": 0.1,
"url": "http://secunia.com/gfx/pdf/secunia_half_year_report_2010.pdf"
},
{
"trust": 0.1,
"url": "http://secunia.com/advisories/about_secunia_advisories/"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2010-1369"
},
{
"db": "VULHUB",
"id": "VHN-45377"
},
{
"db": "VULMON",
"id": "CVE-2010-2772"
},
{
"db": "BID",
"id": "41753"
},
{
"db": "JVNDB",
"id": "JVNDB-2010-001829"
},
{
"db": "PACKETSTORM",
"id": "92130"
},
{
"db": "CNNVD",
"id": "CNNVD-201007-241"
},
{
"db": "NVD",
"id": "CVE-2010-2772"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "IVD",
"id": "06a89dde-2356-11e6-abef-000c29c66e3d"
},
{
"db": "IVD",
"id": "7d70cfdf-463f-11e9-ad83-000c29342cb1"
},
{
"db": "IVD",
"id": "407e95f0-1fb3-11e6-abef-000c29c66e3d"
},
{
"db": "CNVD",
"id": "CNVD-2010-1369"
},
{
"db": "VULHUB",
"id": "VHN-45377"
},
{
"db": "VULMON",
"id": "CVE-2010-2772"
},
{
"db": "BID",
"id": "41753"
},
{
"db": "JVNDB",
"id": "JVNDB-2010-001829"
},
{
"db": "PACKETSTORM",
"id": "92130"
},
{
"db": "CNNVD",
"id": "CNNVD-201007-241"
},
{
"db": "NVD",
"id": "CVE-2010-2772"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2010-07-23T00:00:00",
"db": "IVD",
"id": "06a89dde-2356-11e6-abef-000c29c66e3d"
},
{
"date": "2010-07-18T00:00:00",
"db": "IVD",
"id": "7d70cfdf-463f-11e9-ad83-000c29342cb1"
},
{
"date": "2010-07-18T00:00:00",
"db": "IVD",
"id": "407e95f0-1fb3-11e6-abef-000c29c66e3d"
},
{
"date": "2010-07-18T00:00:00",
"db": "CNVD",
"id": "CNVD-2010-1369"
},
{
"date": "2010-07-22T00:00:00",
"db": "VULHUB",
"id": "VHN-45377"
},
{
"date": "2010-07-22T00:00:00",
"db": "VULMON",
"id": "CVE-2010-2772"
},
{
"date": "2010-07-16T00:00:00",
"db": "BID",
"id": "41753"
},
{
"date": "2010-08-16T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2010-001829"
},
{
"date": "2010-07-26T12:08:47",
"db": "PACKETSTORM",
"id": "92130"
},
{
"date": "2010-07-23T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201007-241"
},
{
"date": "2010-07-22T05:43:58.250000",
"db": "NVD",
"id": "CVE-2010-2772"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2016-09-13T00:00:00",
"db": "CNVD",
"id": "CNVD-2010-1369"
},
{
"date": "2017-08-17T00:00:00",
"db": "VULHUB",
"id": "VHN-45377"
},
{
"date": "2017-08-17T00:00:00",
"db": "VULMON",
"id": "CVE-2010-2772"
},
{
"date": "2015-03-19T09:27:00",
"db": "BID",
"id": "41753"
},
{
"date": "2024-03-01T04:05:00",
"db": "JVNDB",
"id": "JVNDB-2010-001829"
},
{
"date": "2010-07-23T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201007-241"
},
{
"date": "2024-02-13T16:44:42.830000",
"db": "NVD",
"id": "CVE-2010-2772"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "local",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201007-241"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Siemens SIMATIC WinCC Default Password Security Bypass Vulnerability",
"sources": [
{
"db": "IVD",
"id": "7d70cfdf-463f-11e9-ad83-000c29342cb1"
},
{
"db": "IVD",
"id": "407e95f0-1fb3-11e6-abef-000c29c66e3d"
},
{
"db": "CNVD",
"id": "CNVD-2010-1369"
},
{
"db": "BID",
"id": "41753"
}
],
"trust": 1.3
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Trust management",
"sources": [
{
"db": "IVD",
"id": "06a89dde-2356-11e6-abef-000c29c66e3d"
},
{
"db": "IVD",
"id": "7d70cfdf-463f-11e9-ad83-000c29342cb1"
},
{
"db": "IVD",
"id": "407e95f0-1fb3-11e6-abef-000c29c66e3d"
},
{
"db": "CNNVD",
"id": "CNNVD-201007-241"
}
],
"trust": 1.2
}
}
VAR-202306-0974
Vulnerability from variot - Updated: 2023-12-24 19:17A vulnerability has been identified in SIMATIC NET PC Software V14 (All versions), SIMATIC NET PC Software V15 (All versions), SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions), SIMATIC PCS 7 V9.1 (All versions), SIMATIC WinCC (All versions < V8.0), SINAUT Software ST7sc (All versions). Before SIMATIC WinCC V8, legacy OPC services (OPC DA (Data Access), OPC HDA (Historical Data Access), and OPC AE (Alarms & Events)) were used per default. These services were designed on top of the Windows ActiveX and DCOM mechanisms and do not implement state-of-the-art security mechanisms for authentication and encryption of contents. simatic net pc software , SIMATIC PCS 7 , SIMATIC WinCC Unspecified vulnerabilities exist in multiple Siemens products.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202306-0974",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "simatic pcs 7",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "8.2"
},
{
"model": "simatic wincc",
"scope": "lt",
"trust": 1.0,
"vendor": "siemens",
"version": "8.0"
},
{
"model": "simatic pcs 7",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "9.0"
},
{
"model": "sinaut st7sc",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "*"
},
{
"model": "simatic net pc software",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "15.0"
},
{
"model": "simatic pcs 7",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "9.1"
},
{
"model": "simatic net pc software",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "14.0"
},
{
"model": "simatic pcs 7",
"scope": null,
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": null
},
{
"model": "simatic wincc",
"scope": null,
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": null
},
{
"model": "simatic net pc software",
"scope": null,
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": null
},
{
"model": "sinaut st7sc",
"scope": null,
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": null
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-014286"
},
{
"db": "NVD",
"id": "CVE-2023-28829"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:a:siemens:simatic_pcs_7:9.0:-:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:simatic_pcs_7:9.1:-:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:simatic_pcs_7:8.2:-:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:simatic_net_pc_software:15.0:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:simatic_net_pc_software:14.0:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:simatic_wincc:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "8.0",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:sinaut_st7sc:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2023-28829"
}
]
},
"cve": "CVE-2023-28829",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "NVD",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 2.8,
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "HIGH",
"attackVector": "ADJACENT_NETWORK",
"author": "productcert@siemens.com",
"availabilityImpact": "LOW",
"baseScore": 3.9,
"baseSeverity": "LOW",
"confidentialityImpact": "LOW",
"exploitabilityScore": 0.5,
"impactScore": 3.4,
"integrityImpact": "LOW",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:H/PR:H/UI:N/S:U/C:L/I:L/A:L",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 8.8,
"baseSeverity": "High",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "CVE-2023-28829",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "Low",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2023-28829",
"trust": 1.8,
"value": "HIGH"
},
{
"author": "productcert@siemens.com",
"id": "CVE-2023-28829",
"trust": 1.0,
"value": "LOW"
},
{
"author": "CNNVD",
"id": "CNNVD-202306-882",
"trust": 0.6,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-014286"
},
{
"db": "NVD",
"id": "CVE-2023-28829"
},
{
"db": "NVD",
"id": "CVE-2023-28829"
},
{
"db": "CNNVD",
"id": "CNNVD-202306-882"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "A vulnerability has been identified in SIMATIC NET PC Software V14 (All versions), SIMATIC NET PC Software V15 (All versions), SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions), SIMATIC PCS 7 V9.1 (All versions), SIMATIC WinCC (All versions \u003c V8.0), SINAUT Software ST7sc (All versions). Before SIMATIC WinCC V8, legacy OPC services (OPC DA (Data Access), OPC HDA (Historical Data Access), and OPC AE (Alarms \u0026 Events)) were used per default. These\r\nservices were designed on top of the Windows ActiveX and DCOM mechanisms and do not implement state-of-the-art security mechanisms for authentication and encryption of contents. simatic net pc software , SIMATIC PCS 7 , SIMATIC WinCC Unspecified vulnerabilities exist in multiple Siemens products.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state",
"sources": [
{
"db": "NVD",
"id": "CVE-2023-28829"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-014286"
},
{
"db": "VULMON",
"id": "CVE-2023-28829"
}
],
"trust": 1.71
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2023-28829",
"trust": 3.3
},
{
"db": "SIEMENS",
"id": "SSA-508677",
"trust": 2.5
},
{
"db": "JVN",
"id": "JVNVU99464755",
"trust": 0.8
},
{
"db": "ICS CERT",
"id": "ICSA-23-166-05",
"trust": 0.8
},
{
"db": "JVNDB",
"id": "JVNDB-2023-014286",
"trust": 0.8
},
{
"db": "CNNVD",
"id": "CNNVD-202306-882",
"trust": 0.6
},
{
"db": "VULMON",
"id": "CVE-2023-28829",
"trust": 0.1
}
],
"sources": [
{
"db": "VULMON",
"id": "CVE-2023-28829"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-014286"
},
{
"db": "NVD",
"id": "CVE-2023-28829"
},
{
"db": "CNNVD",
"id": "CNNVD-202306-882"
}
]
},
"id": "VAR-202306-0974",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "VARIoT devices database",
"id": null
}
],
"trust": 0.609197615
},
"last_update_date": "2023-12-24T19:17:59.466000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Siemens SIMATIC PCS 7 Security vulnerabilities",
"trust": 0.6,
"url": "http://123.124.177.30/web/xxk/bdxqbyid.tag?id=244458"
}
],
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202306-882"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "NVD-CWE-noinfo",
"trust": 1.0
},
{
"problemtype": "Lack of information (CWE-noinfo) [NVD evaluation ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-014286"
},
{
"db": "NVD",
"id": "CVE-2023-28829"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.5,
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-508677.pdf"
},
{
"trust": 0.8,
"url": "https://jvn.jp/vu/jvnvu99464755/"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2023-28829"
},
{
"trust": 0.8,
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-166-05"
},
{
"trust": 0.6,
"url": "https://cxsecurity.com/cveshow/cve-2023-28829/"
},
{
"trust": 0.1,
"url": "https://nvd.nist.gov"
}
],
"sources": [
{
"db": "VULMON",
"id": "CVE-2023-28829"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-014286"
},
{
"db": "NVD",
"id": "CVE-2023-28829"
},
{
"db": "CNNVD",
"id": "CNNVD-202306-882"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "VULMON",
"id": "CVE-2023-28829"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-014286"
},
{
"db": "NVD",
"id": "CVE-2023-28829"
},
{
"db": "CNNVD",
"id": "CNNVD-202306-882"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2023-06-13T00:00:00",
"db": "VULMON",
"id": "CVE-2023-28829"
},
{
"date": "2023-12-22T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2023-014286"
},
{
"date": "2023-06-13T09:15:16.707000",
"db": "NVD",
"id": "CVE-2023-28829"
},
{
"date": "2023-06-13T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202306-882"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2023-06-13T00:00:00",
"db": "VULMON",
"id": "CVE-2023-28829"
},
{
"date": "2023-12-22T08:15:00",
"db": "JVNDB",
"id": "JVNDB-2023-014286"
},
{
"date": "2023-07-05T17:36:45.750000",
"db": "NVD",
"id": "CVE-2023-28829"
},
{
"date": "2023-07-06T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202306-882"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202306-882"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Vulnerabilities in multiple Siemens products",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-014286"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "other",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202306-882"
}
],
"trust": 0.6
}
}
VAR-201702-0669
Vulnerability from variot - Updated: 2023-12-18 13:57Siemens SIMATIC Logon prior to V1.5 SP3 Update 2 could allow an attacker with knowledge of a valid user name, and physical or network access to the affected system, to bypass the application-level authentication. SIMATIC WinCC, SIMATIC PCS 7, SIMATIC PDM and SIMATIC IT are all industrial automation products from Siemens AG.
There is a certification bypass vulnerability in SIEMENS SIMATIC Logon. An attacker could exploit the vulnerability to bypass authentication mechanisms and perform unauthorized operations. This may aid in further attacks. Siemens SIMATIC WinCC, etc. Siemens SIMATIC WinCC is an automated data acquisition and monitoring (SCADA) system; SIMATIC PCS 7 is a distributed process control system using WinCC. A security vulnerability exists in versions prior to SIMATIC Logon 1.5 SP3 Update 2 in several Siemens SIMATIC products. The following products and versions are affected: Siemens SIMATIC WinCC Version 7.x; SIMATIC WinCC Runtime Professional; SIMATIC PCS 7; SIMATIC PDM; SIMATIC IT
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-201702-0669",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "simatic logon",
"scope": "lte",
"trust": 1.0,
"vendor": "siemens",
"version": "1.5"
},
{
"model": "simatic logon",
"scope": "lt",
"trust": 0.8,
"vendor": "siemens",
"version": "1.5 sp3 update 2"
},
{
"model": "simatic wincc",
"scope": "eq",
"trust": 0.6,
"vendor": "siemens",
"version": "7.x"
},
{
"model": "simatic wincc runtime professional",
"scope": null,
"trust": 0.6,
"vendor": "siemens",
"version": null
},
{
"model": "simatic pcs",
"scope": "eq",
"trust": 0.6,
"vendor": "siemens",
"version": "7"
},
{
"model": "simatic pdm",
"scope": null,
"trust": 0.6,
"vendor": "siemens",
"version": null
},
{
"model": "simatic it",
"scope": null,
"trust": 0.6,
"vendor": "siemens",
"version": null
},
{
"model": "simatic logon",
"scope": "eq",
"trust": 0.6,
"vendor": "siemens",
"version": "1.5"
},
{
"model": "simatic wincc runtime professional",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "0"
},
{
"model": "simatic wincc update",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "7.41"
},
{
"model": "simatic wincc",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "7.4"
},
{
"model": "simatic wincc update",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "7.32"
},
{
"model": "simatic wincc update",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "7.310"
},
{
"model": "simatic wincc update",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "7.31"
},
{
"model": "simatic wincc upd4",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "7.3"
},
{
"model": "simatic wincc",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "7.3"
},
{
"model": "simatic wincc update",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "7.29"
},
{
"model": "simatic wincc update",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "7.28"
},
{
"model": "simatic wincc update",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "7.21"
},
{
"model": "simatic wincc upd4",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "7.2"
},
{
"model": "simatic wincc upd11",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "7.2"
},
{
"model": "simatic wincc",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "7.2"
},
{
"model": "simatic wincc sp3 upd",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "7.08"
},
{
"model": "simatic wincc sp3",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "7.0"
},
{
"model": "simatic wincc sp2 upd",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "7.012"
},
{
"model": "simatic wincc sp2",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "7.0"
},
{
"model": "simatic wincc sp",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "7.03"
},
{
"model": "simatic wincc sp",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "7.02"
},
{
"model": "simatic wincc",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "7.0"
},
{
"model": "simatic pdm",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "0"
},
{
"model": "simatic pcs",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "78.2"
},
{
"model": "simatic pcs sp1",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "78.1"
},
{
"model": "simatic pcs",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "78.1"
},
{
"model": "simatic pcs sp1",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "78.0"
},
{
"model": "simatic pcs",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "78.0"
},
{
"model": "simatic pcs",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "78"
},
{
"model": "simatic pcs sp4",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "77.1"
},
{
"model": "simatic pcs",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "77.1"
},
{
"model": "simatic pcs",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "77"
},
{
"model": "simatic logon",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "0"
},
{
"model": "simatic it",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "0"
},
{
"model": "simatic logon sp3 update",
"scope": "ne",
"trust": 0.3,
"vendor": "siemens",
"version": "1.52"
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "simatic logon",
"version": "*"
}
],
"sources": [
{
"db": "IVD",
"id": "9bc72032-e004-41ac-bce6-0e6ff85b8945"
},
{
"db": "CNVD",
"id": "CNVD-2017-01343"
},
{
"db": "BID",
"id": "96208"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-002227"
},
{
"db": "NVD",
"id": "CVE-2017-2684"
},
{
"db": "CNNVD",
"id": "CNNVD-201702-612"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:a:siemens:simatic_logon:*:sp3_update_1:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "1.5",
"vulnerable": true
}
],
"operator": "OR"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2017-2684"
}
]
},
"credits": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/credits#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "The vendor reported the issue.",
"sources": [
{
"db": "BID",
"id": "96208"
}
],
"trust": 0.3
},
"cve": "CVE-2017-2684",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"acInsufInfo": false,
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "NVD",
"availabilityImpact": "PARTIAL",
"baseScore": 6.8,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 8.6,
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "MEDIUM",
"trust": 1.0,
"userInteractionRequired": false,
"vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
{
"acInsufInfo": null,
"accessComplexity": "Medium",
"accessVector": "Network",
"authentication": "None",
"author": "NVD",
"availabilityImpact": "Partial",
"baseScore": 6.8,
"confidentialityImpact": "Partial",
"exploitabilityScore": null,
"id": "CVE-2017-2684",
"impactScore": null,
"integrityImpact": "Partial",
"obtainAllPrivilege": null,
"obtainOtherPrivilege": null,
"obtainUserPrivilege": null,
"severity": "Medium",
"trust": 0.8,
"userInteractionRequired": null,
"vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
{
"accessComplexity": "HIGH",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 7.6,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 4.9,
"id": "CNVD-2017-01343",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:H/Au:N/C:C/I:C/A:C",
"version": "2.0"
},
{
"accessComplexity": "HIGH",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "IVD",
"availabilityImpact": "COMPLETE",
"baseScore": 7.6,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 4.9,
"id": "9bc72032-e004-41ac-bce6-0e6ff85b8945",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.2,
"vectorString": "AV:N/AC:H/Au:N/C:C/I:C/A:C",
"version": "2.9 [IVD]"
},
{
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "VULHUB",
"availabilityImpact": "PARTIAL",
"baseScore": 6.8,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 8.6,
"id": "VHN-110887",
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"severity": "MEDIUM",
"trust": 0.1,
"vectorString": "AV:N/AC:M/AU:N/C:P/I:P/A:P",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"author": "NVD",
"availabilityImpact": "HIGH",
"baseScore": 9.0,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 2.2,
"impactScore": 6.0,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:C/C:H/I:H/A:H",
"version": "3.0"
},
{
"attackComplexity": "High",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 9.0,
"baseSeverity": "Critical",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "CVE-2017-2684",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "None",
"scope": "Changed",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:C/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2017-2684",
"trust": 1.8,
"value": "CRITICAL"
},
{
"author": "CNVD",
"id": "CNVD-2017-01343",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "CNNVD",
"id": "CNNVD-201702-612",
"trust": 0.6,
"value": "CRITICAL"
},
{
"author": "IVD",
"id": "9bc72032-e004-41ac-bce6-0e6ff85b8945",
"trust": 0.2,
"value": "CRITICAL"
},
{
"author": "VULHUB",
"id": "VHN-110887",
"trust": 0.1,
"value": "MEDIUM"
}
]
}
],
"sources": [
{
"db": "IVD",
"id": "9bc72032-e004-41ac-bce6-0e6ff85b8945"
},
{
"db": "CNVD",
"id": "CNVD-2017-01343"
},
{
"db": "VULHUB",
"id": "VHN-110887"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-002227"
},
{
"db": "NVD",
"id": "CVE-2017-2684"
},
{
"db": "CNNVD",
"id": "CNNVD-201702-612"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Siemens SIMATIC Logon prior to V1.5 SP3 Update 2 could allow an attacker with knowledge of a valid user name, and physical or network access to the affected system, to bypass the application-level authentication. SIMATIC WinCC, SIMATIC PCS 7, SIMATIC PDM and SIMATIC IT are all industrial automation products from Siemens AG. \n\nThere is a certification bypass vulnerability in SIEMENS SIMATIC Logon. An attacker could exploit the vulnerability to bypass authentication mechanisms and perform unauthorized operations. This may aid in further attacks. Siemens SIMATIC WinCC, etc. Siemens SIMATIC WinCC is an automated data acquisition and monitoring (SCADA) system; SIMATIC PCS 7 is a distributed process control system using WinCC. A security vulnerability exists in versions prior to SIMATIC Logon 1.5 SP3 Update 2 in several Siemens SIMATIC products. The following products and versions are affected: Siemens SIMATIC WinCC Version 7.x; SIMATIC WinCC Runtime Professional; SIMATIC PCS 7; SIMATIC PDM; SIMATIC IT",
"sources": [
{
"db": "NVD",
"id": "CVE-2017-2684"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-002227"
},
{
"db": "CNVD",
"id": "CNVD-2017-01343"
},
{
"db": "BID",
"id": "96208"
},
{
"db": "IVD",
"id": "9bc72032-e004-41ac-bce6-0e6ff85b8945"
},
{
"db": "VULHUB",
"id": "VHN-110887"
}
],
"trust": 2.7
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2017-2684",
"trust": 3.6
},
{
"db": "SIEMENS",
"id": "SSA-931064",
"trust": 2.3
},
{
"db": "BID",
"id": "96208",
"trust": 2.0
},
{
"db": "ICS CERT",
"id": "ICSA-17-045-03",
"trust": 1.1
},
{
"db": "CNNVD",
"id": "CNNVD-201702-612",
"trust": 0.9
},
{
"db": "CNVD",
"id": "CNVD-2017-01343",
"trust": 0.8
},
{
"db": "JVNDB",
"id": "JVNDB-2017-002227",
"trust": 0.8
},
{
"db": "IVD",
"id": "9BC72032-E004-41AC-BCE6-0E6FF85B8945",
"trust": 0.2
},
{
"db": "VULHUB",
"id": "VHN-110887",
"trust": 0.1
}
],
"sources": [
{
"db": "IVD",
"id": "9bc72032-e004-41ac-bce6-0e6ff85b8945"
},
{
"db": "CNVD",
"id": "CNVD-2017-01343"
},
{
"db": "VULHUB",
"id": "VHN-110887"
},
{
"db": "BID",
"id": "96208"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-002227"
},
{
"db": "NVD",
"id": "CVE-2017-2684"
},
{
"db": "CNNVD",
"id": "CNNVD-201702-612"
}
]
},
"id": "VAR-201702-0669",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "IVD",
"id": "9bc72032-e004-41ac-bce6-0e6ff85b8945"
},
{
"db": "CNVD",
"id": "CNVD-2017-01343"
},
{
"db": "VULHUB",
"id": "VHN-110887"
}
],
"trust": 1.545470526
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"ICS"
],
"sub_category": null,
"trust": 0.8
}
],
"sources": [
{
"db": "IVD",
"id": "9bc72032-e004-41ac-bce6-0e6ff85b8945"
},
{
"db": "CNVD",
"id": "CNVD-2017-01343"
}
]
},
"last_update_date": "2023-12-18T13:57:27.176000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "SSA-931064",
"trust": 0.8,
"url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-931064.pdf"
},
{
"title": "Patch for SIEMENS SIMATIC Logon Certification Bypass Vulnerability",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchinfo/show/176385"
},
{
"title": "Multiple Siemens SIMATIC Product security vulnerabilities",
"trust": 0.6,
"url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=68203"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2017-01343"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-002227"
},
{
"db": "CNNVD",
"id": "CNNVD-201702-612"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "NVD-CWE-noinfo",
"trust": 1.0
},
{
"problemtype": "CWE-284",
"trust": 0.9
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-110887"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-002227"
},
{
"db": "NVD",
"id": "CVE-2017-2684"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.3,
"url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-931064.pdf"
},
{
"trust": 1.7,
"url": "http://www.securityfocus.com/bid/96208"
},
{
"trust": 1.1,
"url": "https://ics-cert.us-cert.gov/advisories/icsa-17-045-03"
},
{
"trust": 0.8,
"url": "http://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2017-2684"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2017-2684"
},
{
"trust": 0.6,
"url": "http://www.siemens.com/cert/en/cert-security-advisories.htm"
},
{
"trust": 0.3,
"url": "http://www.siemens.com/"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2017-01343"
},
{
"db": "VULHUB",
"id": "VHN-110887"
},
{
"db": "BID",
"id": "96208"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-002227"
},
{
"db": "NVD",
"id": "CVE-2017-2684"
},
{
"db": "CNNVD",
"id": "CNNVD-201702-612"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "IVD",
"id": "9bc72032-e004-41ac-bce6-0e6ff85b8945"
},
{
"db": "CNVD",
"id": "CNVD-2017-01343"
},
{
"db": "VULHUB",
"id": "VHN-110887"
},
{
"db": "BID",
"id": "96208"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-002227"
},
{
"db": "NVD",
"id": "CVE-2017-2684"
},
{
"db": "CNNVD",
"id": "CNNVD-201702-612"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2017-02-14T00:00:00",
"db": "IVD",
"id": "9bc72032-e004-41ac-bce6-0e6ff85b8945"
},
{
"date": "2017-02-14T00:00:00",
"db": "CNVD",
"id": "CNVD-2017-01343"
},
{
"date": "2017-02-22T00:00:00",
"db": "VULHUB",
"id": "VHN-110887"
},
{
"date": "2017-02-14T00:00:00",
"db": "BID",
"id": "96208"
},
{
"date": "2017-04-05T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2017-002227"
},
{
"date": "2017-02-22T02:59:00.153000",
"db": "NVD",
"id": "CVE-2017-2684"
},
{
"date": "2017-02-20T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201702-612"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2019-08-22T00:00:00",
"db": "CNVD",
"id": "CNVD-2017-01343"
},
{
"date": "2019-10-09T00:00:00",
"db": "VULHUB",
"id": "VHN-110887"
},
{
"date": "2017-03-07T04:02:00",
"db": "BID",
"id": "96208"
},
{
"date": "2017-09-11T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2017-002227"
},
{
"date": "2019-10-09T23:27:06.587000",
"db": "NVD",
"id": "CVE-2017-2684"
},
{
"date": "2019-10-17T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201702-612"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201702-612"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Siemens SIMATIC Logon Vulnerabilities that bypass application-level authentication",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2017-002227"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "lack of information",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201702-612"
}
],
"trust": 0.6
}
}
VAR-201708-0476
Vulnerability from variot - Updated: 2023-12-18 13:24An XXE vulnerability has been identified in OPC Foundation UA .NET Sample Code before 2017-03-21 and Local Discovery Server (LDS) before 1.03.367. Among the affected products are Siemens SIMATIC PCS7 (All versions V8.1 and earlier), SIMATIC WinCC (All versions < V7.4 SP1), SIMATIC WinCC Runtime Professional (All versions < V14 SP1), SIMATIC NET PC Software, and SIMATIC IT Production Suite. By sending specially crafted packets to the OPC Discovery Server at port 4840/tcp, an attacker might cause the system to access various resources chosen by the attacker. Siemens industrial products are based on the OPC UAP protocol based on OPC to discover and configure LAN device information.
The Siemens OPC UA protocol has an XML external entity vulnerability. Attackers can exploit this issue to gain access to sensitive information or cause denial-of-service conditions. Siemens SIMATIC PCS and so on are all products of German Siemens (Siemens). Siemens SIMATIC PCS is a process control system. SIMATIC WinCC is a set of automatic data acquisition and monitoring (SCADA) system
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-201708-0476",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "simatic pcs7",
"scope": "lte",
"trust": 1.0,
"vendor": "siemens",
"version": "8.1"
},
{
"model": "local discovery server",
"scope": "lte",
"trust": 1.0,
"vendor": "ocpfoundation",
"version": "1.01.333.0"
},
{
"model": "wincc",
"scope": "lte",
"trust": 1.0,
"vendor": "siemens",
"version": "7.4"
},
{
"model": "ua .net",
"scope": "lte",
"trust": 1.0,
"vendor": "ocpfoundation",
"version": "2017-03-21"
},
{
"model": "simatic pcs",
"scope": "eq",
"trust": 0.9,
"vendor": "siemens",
"version": "78.0"
},
{
"model": "simatic pcs",
"scope": "eq",
"trust": 0.9,
"vendor": "siemens",
"version": "78.1"
},
{
"model": "simatic wincc",
"scope": "eq",
"trust": 0.9,
"vendor": "siemens",
"version": "7.0"
},
{
"model": "simatic wincc",
"scope": "eq",
"trust": 0.9,
"vendor": "siemens",
"version": "7.2"
},
{
"model": "simatic wincc",
"scope": "eq",
"trust": 0.9,
"vendor": "siemens",
"version": "7.3"
},
{
"model": "local discovery server",
"scope": "lt",
"trust": 0.8,
"vendor": "opc",
"version": "1.03.367"
},
{
"model": "ua .net",
"scope": "eq",
"trust": 0.8,
"vendor": "opc",
"version": "2017-03-21"
},
{
"model": "simatic it production suite",
"scope": null,
"trust": 0.8,
"vendor": "siemens",
"version": null
},
{
"model": "simatic net pc software",
"scope": null,
"trust": 0.8,
"vendor": "siemens",
"version": null
},
{
"model": "simatic pcs 7",
"scope": null,
"trust": 0.8,
"vendor": "siemens",
"version": null
},
{
"model": "simatic wincc",
"scope": null,
"trust": 0.8,
"vendor": "siemens",
"version": null
},
{
"model": "simatic wincc runtime professional",
"scope": null,
"trust": 0.8,
"vendor": "siemens",
"version": null
},
{
"model": "simatic it production suite all",
"scope": null,
"trust": 0.6,
"vendor": "siemens",
"version": null
},
{
"model": "simatic net pc-software",
"scope": null,
"trust": 0.6,
"vendor": "siemens",
"version": null
},
{
"model": "simatic pcs",
"scope": "eq",
"trust": 0.6,
"vendor": "siemens",
"version": "7\u003c=7.1"
},
{
"model": "simatic wincc sp1",
"scope": "lt",
"trust": 0.6,
"vendor": "siemens",
"version": "v7.4"
},
{
"model": "simatic wincc runtime professional",
"scope": "lt",
"trust": 0.6,
"vendor": "siemens",
"version": "v13"
},
{
"model": "simatic wincc runtime professional sp1",
"scope": "lt",
"trust": 0.6,
"vendor": "siemens",
"version": "v14"
},
{
"model": "local discovery server",
"scope": "eq",
"trust": 0.6,
"vendor": "ocpfoundation",
"version": "1.01.333.0"
},
{
"model": "ua .net",
"scope": "eq",
"trust": 0.6,
"vendor": "ocpfoundation",
"version": "2017-03-21"
},
{
"model": "simatic wincc runtime professional",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "14"
},
{
"model": "simatic wincc runtime professional",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "13"
},
{
"model": "simatic wincc",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "7.4"
},
{
"model": "simatic pcs",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "77.1"
},
{
"model": "simatic net pc-software",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "14"
},
{
"model": "simatic net pc-software sp2",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "13"
},
{
"model": "simatic net pc-software hf1",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "13"
},
{
"model": "simatic net pc-software",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "13"
},
{
"model": "simatic net pc-software sp2 hf3",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "12"
},
{
"model": "simatic net pc-software",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "12"
},
{
"model": "simatic it production suite",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "0"
},
{
"model": "plant connectivity",
"scope": "eq",
"trust": 0.3,
"vendor": "sap",
"version": "15.0"
},
{
"model": "simatic wincc runtime professional sp1",
"scope": "ne",
"trust": 0.3,
"vendor": "siemens",
"version": "14"
},
{
"model": "simatic wincc sp1",
"scope": "ne",
"trust": 0.3,
"vendor": "siemens",
"version": "7.4"
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "simatic pcs7",
"version": "*"
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "wincc",
"version": "*"
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "local discovery server",
"version": "*"
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "ua net",
"version": "*"
}
],
"sources": [
{
"db": "IVD",
"id": "e3c681f4-90be-4763-9ea0-9bf8b55433bb"
},
{
"db": "CNVD",
"id": "CNVD-2017-24363"
},
{
"db": "BID",
"id": "100559"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-008019"
},
{
"db": "NVD",
"id": "CVE-2017-12069"
},
{
"db": "CNNVD",
"id": "CNNVD-201708-1273"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:a:siemens:wincc:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "7.4",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:simatic_pcs7:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "8.1",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:a:ocpfoundation:ua_.net:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "2017-03-21",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:ocpfoundation:local_discovery_server:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "1.01.333.0",
"vulnerable": true
}
],
"operator": "OR"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2017-12069"
}
]
},
"credits": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/credits#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Sergey Temnikov of Kaspersky Lab.",
"sources": [
{
"db": "BID",
"id": "100559"
}
],
"trust": 0.3
},
"cve": "CVE-2017-12069",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"acInsufInfo": true,
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "NVD",
"availabilityImpact": "PARTIAL",
"baseScore": 6.4,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 10.0,
"impactScore": 4.9,
"integrityImpact": "NONE",
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "MEDIUM",
"trust": 1.0,
"userInteractionRequired": false,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:P",
"version": "2.0"
},
{
"acInsufInfo": null,
"accessComplexity": "Low",
"accessVector": "Network",
"authentication": "None",
"author": "NVD",
"availabilityImpact": "Partial",
"baseScore": 6.4,
"confidentialityImpact": "Partial",
"exploitabilityScore": null,
"id": "CVE-2017-12069",
"impactScore": null,
"integrityImpact": "None",
"obtainAllPrivilege": null,
"obtainOtherPrivilege": null,
"obtainUserPrivilege": null,
"severity": "Medium",
"trust": 0.9,
"userInteractionRequired": null,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:P",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 8.5,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 10.0,
"id": "CNVD-2017-24363",
"impactScore": 7.8,
"integrityImpact": "NONE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:C",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "IVD",
"availabilityImpact": "COMPLETE",
"baseScore": 8.5,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 10.0,
"id": "e3c681f4-90be-4763-9ea0-9bf8b55433bb",
"impactScore": 7.8,
"integrityImpact": "NONE",
"severity": "HIGH",
"trust": 0.2,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:C",
"version": "2.9 [IVD]"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "VULHUB",
"availabilityImpact": "PARTIAL",
"baseScore": 6.4,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 10.0,
"id": "VHN-102554",
"impactScore": 4.9,
"integrityImpact": "NONE",
"severity": "MEDIUM",
"trust": 0.1,
"vectorString": "AV:N/AC:L/AU:N/C:P/I:N/A:P",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "NVD",
"availabilityImpact": "HIGH",
"baseScore": 8.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "LOW",
"exploitabilityScore": 3.9,
"impactScore": 4.2,
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:H",
"version": "3.0"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 8.2,
"baseSeverity": "High",
"confidentialityImpact": "Low",
"exploitabilityScore": null,
"id": "CVE-2017-12069",
"impactScore": null,
"integrityImpact": "None",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2017-12069",
"trust": 1.8,
"value": "HIGH"
},
{
"author": "CNVD",
"id": "CNVD-2017-24363",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "CNNVD",
"id": "CNNVD-201708-1273",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "IVD",
"id": "e3c681f4-90be-4763-9ea0-9bf8b55433bb",
"trust": 0.2,
"value": "MEDIUM"
},
{
"author": "VULHUB",
"id": "VHN-102554",
"trust": 0.1,
"value": "MEDIUM"
},
{
"author": "VULMON",
"id": "CVE-2017-12069",
"trust": 0.1,
"value": "MEDIUM"
}
]
}
],
"sources": [
{
"db": "IVD",
"id": "e3c681f4-90be-4763-9ea0-9bf8b55433bb"
},
{
"db": "CNVD",
"id": "CNVD-2017-24363"
},
{
"db": "VULHUB",
"id": "VHN-102554"
},
{
"db": "VULMON",
"id": "CVE-2017-12069"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-008019"
},
{
"db": "NVD",
"id": "CVE-2017-12069"
},
{
"db": "CNNVD",
"id": "CNNVD-201708-1273"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "An XXE vulnerability has been identified in OPC Foundation UA .NET Sample Code before 2017-03-21 and Local Discovery Server (LDS) before 1.03.367. Among the affected products are Siemens SIMATIC PCS7 (All versions V8.1 and earlier), SIMATIC WinCC (All versions \u003c V7.4 SP1), SIMATIC WinCC Runtime Professional (All versions \u003c V14 SP1), SIMATIC NET PC Software, and SIMATIC IT Production Suite. By sending specially crafted packets to the OPC Discovery Server at port 4840/tcp, an attacker might cause the system to access various resources chosen by the attacker. Siemens industrial products are based on the OPC UAP protocol based on OPC to discover and configure LAN device information. \n\nThe Siemens OPC UA protocol has an XML external entity vulnerability. \nAttackers can exploit this issue to gain access to sensitive information or cause denial-of-service conditions. Siemens SIMATIC PCS and so on are all products of German Siemens (Siemens). Siemens SIMATIC PCS is a process control system. SIMATIC WinCC is a set of automatic data acquisition and monitoring (SCADA) system",
"sources": [
{
"db": "NVD",
"id": "CVE-2017-12069"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-008019"
},
{
"db": "CNVD",
"id": "CNVD-2017-24363"
},
{
"db": "BID",
"id": "100559"
},
{
"db": "IVD",
"id": "e3c681f4-90be-4763-9ea0-9bf8b55433bb"
},
{
"db": "VULHUB",
"id": "VHN-102554"
},
{
"db": "VULMON",
"id": "CVE-2017-12069"
}
],
"trust": 2.79
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2017-12069",
"trust": 3.7
},
{
"db": "SIEMENS",
"id": "SSA-535640",
"trust": 1.8
},
{
"db": "ICS CERT",
"id": "ICSA-17-243-01",
"trust": 1.6
},
{
"db": "BID",
"id": "100559",
"trust": 1.5
},
{
"db": "SECTRACK",
"id": "1039510",
"trust": 1.2
},
{
"db": "CNNVD",
"id": "CNNVD-201708-1273",
"trust": 0.9
},
{
"db": "CNVD",
"id": "CNVD-2017-24363",
"trust": 0.8
},
{
"db": "ICS CERT",
"id": "ICSA-17-243-01B",
"trust": 0.8
},
{
"db": "JVNDB",
"id": "JVNDB-2017-008019",
"trust": 0.8
},
{
"db": "IVD",
"id": "E3C681F4-90BE-4763-9EA0-9BF8B55433BB",
"trust": 0.2
},
{
"db": "VULHUB",
"id": "VHN-102554",
"trust": 0.1
},
{
"db": "VULMON",
"id": "CVE-2017-12069",
"trust": 0.1
}
],
"sources": [
{
"db": "IVD",
"id": "e3c681f4-90be-4763-9ea0-9bf8b55433bb"
},
{
"db": "CNVD",
"id": "CNVD-2017-24363"
},
{
"db": "VULHUB",
"id": "VHN-102554"
},
{
"db": "VULMON",
"id": "CVE-2017-12069"
},
{
"db": "BID",
"id": "100559"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-008019"
},
{
"db": "NVD",
"id": "CVE-2017-12069"
},
{
"db": "CNNVD",
"id": "CNNVD-201708-1273"
}
]
},
"id": "VAR-201708-0476",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "IVD",
"id": "e3c681f4-90be-4763-9ea0-9bf8b55433bb"
},
{
"db": "CNVD",
"id": "CNVD-2017-24363"
},
{
"db": "VULHUB",
"id": "VHN-102554"
}
],
"trust": 1.4807013
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"ICS"
],
"sub_category": null,
"trust": 0.8
}
],
"sources": [
{
"db": "IVD",
"id": "e3c681f4-90be-4763-9ea0-9bf8b55433bb"
},
{
"db": "CNVD",
"id": "CNVD-2017-24363"
}
]
},
"last_update_date": "2023-12-18T13:24:20.856000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Security Update for the OPC UA .NET Sample Code",
"trust": 0.8,
"url": "https://opcfoundation-onlineapplications.org/faq/securitybulletins/opc_foundation_security_bulletin_cve-2017-12069.pdf"
},
{
"title": "SSA-535640",
"trust": 0.8,
"url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-535640.pdf"
},
{
"title": "Patch for Siemens OPC UA Protocol XML External Entity Vulnerability",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchinfo/show/176381"
},
{
"title": "Multiple Siemens product OPC Foundation UA .NET Sample Code and Local Discovery Server Security vulnerabilities",
"trust": 0.6,
"url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=74833"
},
{
"title": "Siemens Security Advisories: Siemens Security Advisory",
"trust": 0.1,
"url": "https://vulmon.com/vendoradvisory?qidtp=siemens_security_advisories\u0026qid=0561e5e7e515f186e8a5589cf02f38a8"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2017-24363"
},
{
"db": "VULMON",
"id": "CVE-2017-12069"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-008019"
},
{
"db": "CNNVD",
"id": "CNNVD-201708-1273"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-611",
"trust": 1.9
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-102554"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-008019"
},
{
"db": "NVD",
"id": "CVE-2017-12069"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.8,
"url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-535640.pdf"
},
{
"trust": 1.5,
"url": "https://opcfoundation-onlineapplications.org/faq/securitybulletins/opc_foundation_security_bulletin_cve-2017-12069.pdf"
},
{
"trust": 1.2,
"url": "http://www.securityfocus.com/bid/100559"
},
{
"trust": 1.2,
"url": "http://www.securitytracker.com/id/1039510"
},
{
"trust": 0.9,
"url": "https://ics-cert.us-cert.gov/advisories/icsa-17-243-01"
},
{
"trust": 0.8,
"url": "http://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2017-12069"
},
{
"trust": 0.8,
"url": "https://ics-cert.us-cert.gov/advisories/icsa-17-243-01b"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2017-12069"
},
{
"trust": 0.6,
"url": "https://support.industry.siemens.com/cs/ww/en/view/109746038"
},
{
"trust": 0.6,
"url": "https://support.industry.siemens.com/cs/ww/en/view/109746276"
},
{
"trust": 0.6,
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-17-243-01-0"
},
{
"trust": 0.3,
"url": "http://subscriber.communications.siemens.com/"
},
{
"trust": 0.3,
"url": "https://wiki.scn.sap.com/wiki/pages/viewpage.action?pageid=500633095"
},
{
"trust": 0.3,
"url": "https://wiki.scn.sap.com/wiki/pages/viewpage.action?pageid=499356993"
},
{
"trust": 0.1,
"url": "https://cwe.mitre.org/data/definitions/611.html"
},
{
"trust": 0.1,
"url": "https://tools.cisco.com/security/center/viewalert.x?alertid=55504"
},
{
"trust": 0.1,
"url": "https://nvd.nist.gov"
},
{
"trust": 0.1,
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-17-243-01-0"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2017-24363"
},
{
"db": "VULHUB",
"id": "VHN-102554"
},
{
"db": "VULMON",
"id": "CVE-2017-12069"
},
{
"db": "BID",
"id": "100559"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-008019"
},
{
"db": "NVD",
"id": "CVE-2017-12069"
},
{
"db": "CNNVD",
"id": "CNNVD-201708-1273"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "IVD",
"id": "e3c681f4-90be-4763-9ea0-9bf8b55433bb"
},
{
"db": "CNVD",
"id": "CNVD-2017-24363"
},
{
"db": "VULHUB",
"id": "VHN-102554"
},
{
"db": "VULMON",
"id": "CVE-2017-12069"
},
{
"db": "BID",
"id": "100559"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-008019"
},
{
"db": "NVD",
"id": "CVE-2017-12069"
},
{
"db": "CNNVD",
"id": "CNNVD-201708-1273"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2017-09-02T00:00:00",
"db": "IVD",
"id": "e3c681f4-90be-4763-9ea0-9bf8b55433bb"
},
{
"date": "2017-09-01T00:00:00",
"db": "CNVD",
"id": "CNVD-2017-24363"
},
{
"date": "2017-08-30T00:00:00",
"db": "VULHUB",
"id": "VHN-102554"
},
{
"date": "2017-08-30T00:00:00",
"db": "VULMON",
"id": "CVE-2017-12069"
},
{
"date": "2017-08-31T00:00:00",
"db": "BID",
"id": "100559"
},
{
"date": "2017-10-05T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2017-008019"
},
{
"date": "2017-08-30T19:29:00.210000",
"db": "NVD",
"id": "CVE-2017-12069"
},
{
"date": "2017-08-30T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201708-1273"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2019-08-28T00:00:00",
"db": "CNVD",
"id": "CNVD-2017-24363"
},
{
"date": "2017-10-06T00:00:00",
"db": "VULHUB",
"id": "VHN-102554"
},
{
"date": "2017-10-06T00:00:00",
"db": "VULMON",
"id": "CVE-2017-12069"
},
{
"date": "2018-10-12T04:00:00",
"db": "BID",
"id": "100559"
},
{
"date": "2017-10-05T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2017-008019"
},
{
"date": "2017-10-06T01:29:00.443000",
"db": "NVD",
"id": "CVE-2017-12069"
},
{
"date": "2020-08-12T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201708-1273"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201708-1273"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Siemens OPC UA protocol XML External entity vulnerability",
"sources": [
{
"db": "IVD",
"id": "e3c681f4-90be-4763-9ea0-9bf8b55433bb"
},
{
"db": "CNVD",
"id": "CNVD-2017-24363"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "code problem",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201708-1273"
}
],
"trust": 0.6
}
}
VAR-201812-0345
Vulnerability from variot - Updated: 2023-12-18 13:18A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V14), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions < V14), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V14), SIMATIC WinCC Runtime Advanced (All versions < V14), SIMATIC WinCC Runtime Professional (All versions < V14), SIMATIC WinCC (TIA Portal) (All versions < V14), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). The integrated web server (port 80/tcp and port 443/tcp) of the affected devices could allow an attacker to inject HTTP headers. An attacker must trick a valid user who is authenticated to the device into clicking on a malicious link to exploit the vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known. plural SIMATIC The product contains an input validation vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. Siemens SIMATIC Panels and SIMATIC WinCC (TIA Portal) are products of Siemens AG, Germany. Siemens SIMATIC Panels is a human interface panel. SIMATIC WinCC is an automated data acquisition and monitoring (SCADA) system. A code injection vulnerability exists in Siemens SIMATIC Panels and SIMATIC WinCC (TIA Portal), which can be exploited by an attacker to inject HTTP headers with malicious links. Multiple Siemens Products are prone to an HTTP header-injection vulnerability because it fails to sufficiently sanitize user input. This may aid in further attacks
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-201812-0345",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "simatic hmi ktp mobile panels ktp900f",
"scope": "lt",
"trust": 1.0,
"vendor": "siemens",
"version": "14.0"
},
{
"model": "simatic wincc runtime",
"scope": "lt",
"trust": 1.0,
"vendor": "siemens",
"version": "14.0"
},
{
"model": "simatic hmi op",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "*"
},
{
"model": "simatic hmi ktp mobile panels ktp700f",
"scope": "lt",
"trust": 1.0,
"vendor": "siemens",
"version": "14.0"
},
{
"model": "simatic hmi ktp mobile panels ktp400f",
"scope": "lt",
"trust": 1.0,
"vendor": "siemens",
"version": "14.0"
},
{
"model": "simatic wincc \\",
"scope": "lt",
"trust": 1.0,
"vendor": "siemens",
"version": "14.0"
},
{
"model": "simatic hmi ktp mobile panels ktp900",
"scope": "lt",
"trust": 1.0,
"vendor": "siemens",
"version": "14.0"
},
{
"model": "simatic hmi tp",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "*"
},
{
"model": "simatic hmi comfort panels",
"scope": "lt",
"trust": 1.0,
"vendor": "siemens",
"version": "14.0"
},
{
"model": "simatic hmi mp",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "*"
},
{
"model": "simatic hmi comfort outdoor panels",
"scope": "lt",
"trust": 1.0,
"vendor": "siemens",
"version": "14.0"
},
{
"model": "simatic hmi ktp mobile panels ktp700",
"scope": "lt",
"trust": 1.0,
"vendor": "siemens",
"version": "14.0"
},
{
"model": "simatic hmi comfort outdoor panels",
"scope": null,
"trust": 0.8,
"vendor": "siemens",
"version": null
},
{
"model": "simatic hmi comfort panels",
"scope": null,
"trust": 0.8,
"vendor": "siemens",
"version": null
},
{
"model": "simatic hmi ktp mobile panels ktp400f",
"scope": null,
"trust": 0.8,
"vendor": "siemens",
"version": null
},
{
"model": "simatic hmi ktp mobile panels ktp700",
"scope": null,
"trust": 0.8,
"vendor": "siemens",
"version": null
},
{
"model": "simatic hmi ktp mobile panels ktp700f",
"scope": null,
"trust": 0.8,
"vendor": "siemens",
"version": null
},
{
"model": "simatic hmi ktp mobile panels ktp900",
"scope": null,
"trust": 0.8,
"vendor": "siemens",
"version": null
},
{
"model": "simatic hmi ktp mobile panels ktp900f",
"scope": null,
"trust": 0.8,
"vendor": "siemens",
"version": null
},
{
"model": "simatic wincc",
"scope": null,
"trust": 0.8,
"vendor": "siemens",
"version": null
},
{
"model": "simatic wincc runtime advanced",
"scope": null,
"trust": 0.8,
"vendor": "siemens",
"version": null
},
{
"model": "simatic wincc runtime professional",
"scope": null,
"trust": 0.8,
"vendor": "siemens",
"version": null
},
{
"model": "simatic hmi comfort panels 4\" 22\"",
"scope": "eq",
"trust": 0.6,
"vendor": "siemens",
"version": "-\u003c14"
},
{
"model": "simatic hmi comfort outdoor panels 7\\\" and 15\\\"",
"scope": "lt",
"trust": 0.6,
"vendor": "siemens",
"version": "14"
},
{
"model": "simatic hmi ktp mobile panels",
"scope": "lt",
"trust": 0.6,
"vendor": "siemens",
"version": "14"
},
{
"model": "simatic wincc runtime advanced",
"scope": "lt",
"trust": 0.6,
"vendor": "siemens",
"version": "14"
},
{
"model": "simatic wincc runtime professional",
"scope": "lt",
"trust": 0.6,
"vendor": "siemens",
"version": "14"
},
{
"model": "simatic wincc",
"scope": "lt",
"trust": 0.6,
"vendor": "siemens",
"version": "14"
},
{
"model": null,
"scope": "eq",
"trust": 0.4,
"vendor": "simatic wincc runtime",
"version": "*"
},
{
"model": "simatic wincc runtime professional",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "13"
},
{
"model": "simatic wincc runtime professional",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "0"
},
{
"model": "simatic wincc runtime advanced",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "13"
},
{
"model": "simatic wincc runtime advanced",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "12"
},
{
"model": "simatic wincc runtime advanced",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "0"
},
{
"model": "simatic wincc",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "v120"
},
{
"model": "simatic wincc",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "v110"
},
{
"model": "simatic wincc",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "v13"
},
{
"model": "simatic wincc",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "v10"
},
{
"model": "simatic hmi ktp mobile panels",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "0"
},
{
"model": "simatic hmi comfort panels",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "4"
},
{
"model": "simatic hmi comfort panels",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "22"
},
{
"model": "simatic hmi comfort panels",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "13"
},
{
"model": "simatic hmi comfort panels",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "12"
},
{
"model": "simatic hmi comfort panels",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "0"
},
{
"model": "simatic hmi comfort outdoor panels",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "0"
},
{
"model": "simatic hmi classic devices",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "0"
},
{
"model": "simatic wincc runtime professional",
"scope": "ne",
"trust": 0.3,
"vendor": "siemens",
"version": "14"
},
{
"model": "simatic wincc runtime advanced",
"scope": "ne",
"trust": 0.3,
"vendor": "siemens",
"version": "v14"
},
{
"model": "simatic wincc",
"scope": "ne",
"trust": 0.3,
"vendor": "siemens",
"version": "v14"
},
{
"model": "simatic hmi ktp mobile panels update",
"scope": "ne",
"trust": 0.3,
"vendor": "siemens",
"version": "154"
},
{
"model": "simatic hmi comfort panels",
"scope": "ne",
"trust": 0.3,
"vendor": "siemens",
"version": "14"
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "simatic hmi comfort panels",
"version": "*"
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "simatic hmi mp",
"version": "*"
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "simatic hmi op",
"version": "*"
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "simatic hmi comfort outdoor panels",
"version": "*"
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "simatic hmi ktp mobile panels ktp400f",
"version": "*"
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "simatic hmi ktp mobile panels ktp700",
"version": "*"
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "simatic hmi ktp mobile panels ktp700f",
"version": "*"
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "simatic hmi ktp mobile panels ktp900",
"version": "*"
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "simatic hmi ktp mobile panels ktp900f",
"version": "*"
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "simatic wincc tia portal",
"version": "*"
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "simatic hmi tp",
"version": "*"
}
],
"sources": [
{
"db": "IVD",
"id": "7d80ae62-463f-11e9-b905-000c29342cb1"
},
{
"db": "CNVD",
"id": "CNVD-2018-25432"
},
{
"db": "BID",
"id": "105931"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-014527"
},
{
"db": "NVD",
"id": "CVE-2018-13814"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "14.0",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:simatic_hmi_comfort_panels:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "14.0",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:simatic_hmi_comfort_outdoor_panels:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "14.0",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp400f:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "14.0",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp700:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "14.0",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp700f:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "14.0",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp900:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "14.0",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp900f:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:a:siemens:simatic_wincc_\\(tia_portal\\):*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "14.0",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:simatic_wincc_runtime:*:*:*:*:advanced:*:*:*",
"cpe_name": [],
"versionEndExcluding": "14.0",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:simatic_wincc_runtime:*:*:*:*:professional:*:*:*",
"cpe_name": [],
"versionEndExcluding": "14.0",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:simatic_hmi_tp_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:simatic_hmi_tp:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:simatic_hmi_mp_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:simatic_hmi_mp:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:simatic_hmi_op_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:simatic_hmi_op:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2018-13814"
}
]
},
"credits": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/credits#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "The vendor reported this issue.",
"sources": [
{
"db": "BID",
"id": "105931"
}
],
"trust": 0.3
},
"cve": "CVE-2018-13814",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"acInsufInfo": false,
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "NVD",
"availabilityImpact": "PARTIAL",
"baseScore": 6.8,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 8.6,
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "MEDIUM",
"trust": 1.0,
"userInteractionRequired": true,
"vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
{
"acInsufInfo": null,
"accessComplexity": "Medium",
"accessVector": "Network",
"authentication": "None",
"author": "NVD",
"availabilityImpact": "Partial",
"baseScore": 6.8,
"confidentialityImpact": "Partial",
"exploitabilityScore": null,
"id": "CVE-2018-13814",
"impactScore": null,
"integrityImpact": "Partial",
"obtainAllPrivilege": null,
"obtainOtherPrivilege": null,
"obtainUserPrivilege": null,
"severity": "Medium",
"trust": 0.8,
"userInteractionRequired": null,
"vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "NONE",
"baseScore": 5.0,
"confidentialityImpact": "NONE",
"exploitabilityScore": 10.0,
"id": "CNVD-2018-25432",
"impactScore": 2.9,
"integrityImpact": "PARTIAL",
"severity": "MEDIUM",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:N/I:P/A:N",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "IVD",
"availabilityImpact": "NONE",
"baseScore": 5.0,
"confidentialityImpact": "NONE",
"exploitabilityScore": 10.0,
"id": "7d80ae62-463f-11e9-b905-000c29342cb1",
"impactScore": 2.9,
"integrityImpact": "PARTIAL",
"severity": "MEDIUM",
"trust": 0.2,
"vectorString": "AV:N/AC:L/Au:N/C:N/I:P/A:N",
"version": "2.9 [IVD]"
},
{
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "VULHUB",
"availabilityImpact": "PARTIAL",
"baseScore": 6.8,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 8.6,
"id": "VHN-123911",
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"severity": "MEDIUM",
"trust": 0.1,
"vectorString": "AV:N/AC:M/AU:N/C:P/I:P/A:P",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "NVD",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 2.8,
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.0"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 8.8,
"baseSeverity": "High",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "CVE-2018-13814",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "Required",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2018-13814",
"trust": 1.8,
"value": "HIGH"
},
{
"author": "CNVD",
"id": "CNVD-2018-25432",
"trust": 0.6,
"value": "MEDIUM"
},
{
"author": "CNNVD",
"id": "CNNVD-201811-488",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "IVD",
"id": "7d80ae62-463f-11e9-b905-000c29342cb1",
"trust": 0.2,
"value": "HIGH"
},
{
"author": "VULHUB",
"id": "VHN-123911",
"trust": 0.1,
"value": "MEDIUM"
}
]
}
],
"sources": [
{
"db": "IVD",
"id": "7d80ae62-463f-11e9-b905-000c29342cb1"
},
{
"db": "CNVD",
"id": "CNVD-2018-25432"
},
{
"db": "VULHUB",
"id": "VHN-123911"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-014527"
},
{
"db": "NVD",
"id": "CVE-2018-13814"
},
{
"db": "CNNVD",
"id": "CNNVD-201811-488"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "A vulnerability has been identified in SIMATIC HMI Comfort Panels 4\" - 22\" (All versions \u003c V14), SIMATIC HMI Comfort Outdoor Panels 7\" \u0026 15\" (All versions \u003c V14), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V14), SIMATIC WinCC Runtime Advanced (All versions \u003c V14), SIMATIC WinCC Runtime Professional (All versions \u003c V14), SIMATIC WinCC (TIA Portal) (All versions \u003c V14), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). The integrated web server (port 80/tcp and port 443/tcp) of the affected devices could allow an attacker to inject HTTP headers. An attacker must trick a valid user who is authenticated to the device into clicking on a malicious link to exploit the vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known. plural SIMATIC The product contains an input validation vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. Siemens SIMATIC Panels and SIMATIC WinCC (TIA Portal) are products of Siemens AG, Germany. Siemens SIMATIC Panels is a human interface panel. SIMATIC WinCC is an automated data acquisition and monitoring (SCADA) system. A code injection vulnerability exists in Siemens SIMATIC Panels and SIMATIC WinCC (TIA Portal), which can be exploited by an attacker to inject HTTP headers with malicious links. Multiple Siemens Products are prone to an HTTP header-injection vulnerability because it fails to sufficiently sanitize user input. This may aid in further attacks",
"sources": [
{
"db": "NVD",
"id": "CVE-2018-13814"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-014527"
},
{
"db": "CNVD",
"id": "CNVD-2018-25432"
},
{
"db": "BID",
"id": "105931"
},
{
"db": "IVD",
"id": "7d80ae62-463f-11e9-b905-000c29342cb1"
},
{
"db": "VULHUB",
"id": "VHN-123911"
}
],
"trust": 2.7
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2018-13814",
"trust": 3.6
},
{
"db": "ICS CERT",
"id": "ICSA-18-317-03",
"trust": 2.3
},
{
"db": "BID",
"id": "105931",
"trust": 2.0
},
{
"db": "SIEMENS",
"id": "SSA-944083",
"trust": 1.7
},
{
"db": "CNNVD",
"id": "CNNVD-201811-488",
"trust": 0.9
},
{
"db": "CNVD",
"id": "CNVD-2018-25432",
"trust": 0.8
},
{
"db": "JVNDB",
"id": "JVNDB-2018-014527",
"trust": 0.8
},
{
"db": "IVD",
"id": "7D80AE62-463F-11E9-B905-000C29342CB1",
"trust": 0.2
},
{
"db": "SEEBUG",
"id": "SSVID-98853",
"trust": 0.1
},
{
"db": "VULHUB",
"id": "VHN-123911",
"trust": 0.1
}
],
"sources": [
{
"db": "IVD",
"id": "7d80ae62-463f-11e9-b905-000c29342cb1"
},
{
"db": "CNVD",
"id": "CNVD-2018-25432"
},
{
"db": "VULHUB",
"id": "VHN-123911"
},
{
"db": "BID",
"id": "105931"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-014527"
},
{
"db": "NVD",
"id": "CVE-2018-13814"
},
{
"db": "CNNVD",
"id": "CNNVD-201811-488"
}
]
},
"id": "VAR-201812-0345",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "IVD",
"id": "7d80ae62-463f-11e9-b905-000c29342cb1"
},
{
"db": "CNVD",
"id": "CNVD-2018-25432"
},
{
"db": "VULHUB",
"id": "VHN-123911"
}
],
"trust": 1.5135283022222223
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"ICS"
],
"sub_category": null,
"trust": 0.8
}
],
"sources": [
{
"db": "IVD",
"id": "7d80ae62-463f-11e9-b905-000c29342cb1"
},
{
"db": "CNVD",
"id": "CNVD-2018-25432"
}
]
},
"last_update_date": "2023-12-18T13:18:52.655000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "SSA-944083",
"trust": 0.8,
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-944083.pdf"
},
{
"title": "Patch for Siemens SIMATIC Panels and SIMATIC WinCC code injection vulnerability",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchinfo/show/147353"
},
{
"title": "Siemens SIMATIC Panels and SIMATIC WinCC Fixes for code injection vulnerabilities",
"trust": 0.6,
"url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=86889"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2018-25432"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-014527"
},
{
"db": "CNNVD",
"id": "CNNVD-201811-488"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-20",
"trust": 1.9
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-123911"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-014527"
},
{
"db": "NVD",
"id": "CVE-2018-13814"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.3,
"url": "https://ics-cert.us-cert.gov/advisories/icsa-18-317-03"
},
{
"trust": 1.7,
"url": "http://www.securityfocus.com/bid/105931"
},
{
"trust": 1.7,
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-944083.pdf"
},
{
"trust": 0.8,
"url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2018-13814"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2018-13814"
},
{
"trust": 0.3,
"url": "http://subscriber.communications.siemens.com/"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2018-25432"
},
{
"db": "VULHUB",
"id": "VHN-123911"
},
{
"db": "BID",
"id": "105931"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-014527"
},
{
"db": "NVD",
"id": "CVE-2018-13814"
},
{
"db": "CNNVD",
"id": "CNNVD-201811-488"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "IVD",
"id": "7d80ae62-463f-11e9-b905-000c29342cb1"
},
{
"db": "CNVD",
"id": "CNVD-2018-25432"
},
{
"db": "VULHUB",
"id": "VHN-123911"
},
{
"db": "BID",
"id": "105931"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-014527"
},
{
"db": "NVD",
"id": "CVE-2018-13814"
},
{
"db": "CNNVD",
"id": "CNNVD-201811-488"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2018-12-14T00:00:00",
"db": "IVD",
"id": "7d80ae62-463f-11e9-b905-000c29342cb1"
},
{
"date": "2018-12-14T00:00:00",
"db": "CNVD",
"id": "CNVD-2018-25432"
},
{
"date": "2018-12-13T00:00:00",
"db": "VULHUB",
"id": "VHN-123911"
},
{
"date": "2018-11-13T00:00:00",
"db": "BID",
"id": "105931"
},
{
"date": "2019-03-26T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2018-014527"
},
{
"date": "2018-12-13T16:29:00.350000",
"db": "NVD",
"id": "CVE-2018-13814"
},
{
"date": "2018-11-15T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201811-488"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2018-12-14T00:00:00",
"db": "CNVD",
"id": "CNVD-2018-25432"
},
{
"date": "2019-10-09T00:00:00",
"db": "VULHUB",
"id": "VHN-123911"
},
{
"date": "2018-11-13T00:00:00",
"db": "BID",
"id": "105931"
},
{
"date": "2019-03-26T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2018-014527"
},
{
"date": "2019-10-09T23:34:33.873000",
"db": "NVD",
"id": "CVE-2018-13814"
},
{
"date": "2019-10-17T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201811-488"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201811-488"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Siemens SIMATIC Panels and SIMATIC WinCC code injection vulnerability",
"sources": [
{
"db": "CNVD",
"id": "CNVD-2018-25432"
},
{
"db": "CNNVD",
"id": "CNNVD-201811-488"
}
],
"trust": 1.2
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Input validation error",
"sources": [
{
"db": "IVD",
"id": "7d80ae62-463f-11e9-b905-000c29342cb1"
},
{
"db": "BID",
"id": "105931"
},
{
"db": "CNNVD",
"id": "CNNVD-201811-488"
}
],
"trust": 1.1
}
}
VAR-201907-1455
Vulnerability from variot - Updated: 2023-12-18 13:18A vulnerability has been identified in SIMATIC PCS 7 V8.0 and earlier (All versions), SIMATIC PCS 7 V8.1 (All versions < V8.1 with WinCC V7.3 Upd 19), SIMATIC PCS 7 V8.2 (All versions < V8.2 SP1 with WinCC V7.4 SP1 Upd 11), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP2 with WinCC V7.4 SP1 Upd11), SIMATIC WinCC Professional (TIA Portal V13) (All versions), SIMATIC WinCC Professional (TIA Portal V14) (All versions < V14 SP1 Upd 9), SIMATIC WinCC Professional (TIA Portal V15) (All versions < V15.1 Upd 3), SIMATIC WinCC Runtime Professional V13 (All versions), SIMATIC WinCC Runtime Professional V14 (All versions < V14.1 Upd 8), SIMATIC WinCC Runtime Professional V15 (All versions < V15.1 Upd 3), SIMATIC WinCC V7.2 and earlier (All versions), SIMATIC WinCC V7.3 (All versions < V7.3 Upd 19), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Upd 11), SIMATIC WinCC V7.5 (All versions < V7.5 Upd 3). The SIMATIC WinCC DataMonitor web application of the affected products allows to upload arbitrary ASPX code. The security vulnerability could be exploited by an authenticated attacker with network access to the WinCC DataMonitor application. No user interaction is required to exploit this vulnerability. The vulnerability impacts confidentiality, integrity, and availability of the affected device. At the stage of publishing this security advisory no public exploitation is known. plural SIMATIC The product contains a vulnerability related to unlimited uploads of dangerous types of files.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. Siemens SIMATIC PCS 7 and SIMATIC WinCC are products of Siemens AG, Germany. SIMATIC PCS 7 is a process control system. SIMATIC WinCC is an automated data acquisition and monitoring (SCADA) system. The SIMATIC WinCC DataMonitor web is one of the data analysis and display components.
A security vulnerability exists in the SIMATIC WinCC DataMonitor web in several Siemens products. Siemens SIMATIC WinCC and SIMATIC PCS 7 are prone to an arbitrary file-upload vulnerability
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-201907-1455",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "simatic wincc",
"scope": "eq",
"trust": 1.3,
"vendor": "siemens",
"version": "7.5"
},
{
"model": "simatic wincc",
"scope": "eq",
"trust": 1.3,
"vendor": "siemens",
"version": "7.4"
},
{
"model": "simatic wincc",
"scope": "eq",
"trust": 1.3,
"vendor": "siemens",
"version": "7.3"
},
{
"model": "simatic pcs 7",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "8.2"
},
{
"model": "simatic pcs 7",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "8.0"
},
{
"model": "simatic wincc",
"scope": "lte",
"trust": 1.0,
"vendor": "siemens",
"version": "7.2"
},
{
"model": "simatic wincc runtime",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "15"
},
{
"model": "simatic wincc runtime",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "14"
},
{
"model": "simatic wincc runtime",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "15.1"
},
{
"model": "simatic wincc",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "15"
},
{
"model": "simatic wincc",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "14"
},
{
"model": "simatic wincc runtime",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "13"
},
{
"model": "simatic pcs 7",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "9.0"
},
{
"model": "simatic wincc",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "13"
},
{
"model": "simatic pcs 7",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "8.1"
},
{
"model": "simatic pcs",
"scope": "eq",
"trust": 0.8,
"vendor": "siemens",
"version": "7v8.0"
},
{
"model": "simatic pcs",
"scope": "eq",
"trust": 0.8,
"vendor": "siemens",
"version": "7v8.1"
},
{
"model": "simatic pcs",
"scope": "eq",
"trust": 0.8,
"vendor": "siemens",
"version": "7v9.0"
},
{
"model": "simatic wincc",
"scope": "eq",
"trust": 0.8,
"vendor": "siemens",
"version": "v7.3"
},
{
"model": "simatic wincc runtime professional",
"scope": "eq",
"trust": 0.8,
"vendor": "siemens",
"version": "v13"
},
{
"model": "simatic wincc runtime professional",
"scope": "eq",
"trust": 0.8,
"vendor": "siemens",
"version": "v14"
},
{
"model": "simatic pcs 7",
"scope": null,
"trust": 0.8,
"vendor": "siemens",
"version": null
},
{
"model": "simatic wincc",
"scope": null,
"trust": 0.8,
"vendor": "siemens",
"version": null
},
{
"model": "simatic wincc runtime professional",
"scope": null,
"trust": 0.8,
"vendor": "siemens",
"version": null
},
{
"model": "simatic pcs",
"scope": "eq",
"trust": 0.6,
"vendor": "siemens",
"version": "7\u003c=v8.0"
},
{
"model": "simatic wincc runtime professional",
"scope": "eq",
"trust": 0.6,
"vendor": "siemens",
"version": "v15"
},
{
"model": "simatic wincc",
"scope": "eq",
"trust": 0.6,
"vendor": "siemens",
"version": "v7.4"
},
{
"model": "simatic wincc",
"scope": "lte",
"trust": 0.6,
"vendor": "siemens",
"version": "\u003c=v7.2"
},
{
"model": "simatic wincc professional (tia portal",
"scope": "eq",
"trust": 0.6,
"vendor": "siemens",
"version": "v13)"
},
{
"model": "simatic wincc professional (tia portal",
"scope": "eq",
"trust": 0.6,
"vendor": "siemens",
"version": "v14)"
},
{
"model": "simatic wincc professional (tia portal",
"scope": "eq",
"trust": 0.6,
"vendor": "siemens",
"version": "v15)"
},
{
"model": "simatic wincc",
"scope": "eq",
"trust": 0.6,
"vendor": "siemens",
"version": "v7.5"
},
{
"model": "simatic wincc runtime professional update",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "v15.11"
},
{
"model": "simatic wincc runtime professional",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "15.1"
},
{
"model": "simatic wincc runtime professional update",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "154"
},
{
"model": "simatic wincc runtime professional",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "15"
},
{
"model": "simatic wincc runtime professional sp1",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "14"
},
{
"model": "simatic wincc runtime professional",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "14"
},
{
"model": "simatic wincc runtime professional sp2",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "13"
},
{
"model": "simatic wincc runtime professional sp1 upd2",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "13"
},
{
"model": "simatic wincc runtime professional sp update",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "1319"
},
{
"model": "simatic wincc runtime professional",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "13"
},
{
"model": "simatic wincc professional",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "15"
},
{
"model": "simatic wincc professional sp1",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "14"
},
{
"model": "simatic wincc professional",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "14"
},
{
"model": "simatic wincc professional sp2",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "13"
},
{
"model": "simatic wincc professional",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "13"
},
{
"model": "simatic wincc update",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "7.41"
},
{
"model": "simatic wincc sp1",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "7.4"
},
{
"model": "simatic wincc update",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "7.32"
},
{
"model": "simatic wincc update",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "7.313"
},
{
"model": "simatic wincc update",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "7.311"
},
{
"model": "simatic wincc update",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "7.310"
},
{
"model": "simatic wincc update",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "7.31"
},
{
"model": "simatic wincc upd4",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "7.3"
},
{
"model": "simatic wincc update",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "7.29"
},
{
"model": "simatic wincc",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "7.2"
},
{
"model": "simatic wincc sp3 upd",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "7.08"
},
{
"model": "simatic wincc",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "7.0"
},
{
"model": "simatic wincc",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "6.2"
},
{
"model": "simatic pcs",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "79.0"
},
{
"model": "simatic pcs",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "78.2"
},
{
"model": "simatic pcs",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "78.1"
},
{
"model": "simatic pcs",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "78.0"
},
{
"model": "simatic wincc update",
"scope": "ne",
"trust": 0.3,
"vendor": "siemens",
"version": "7.53"
},
{
"model": "simatic wincc sp-1 upd-11",
"scope": "ne",
"trust": 0.3,
"vendor": "siemens",
"version": "7.4"
},
{
"model": "simatic pcs sp-2",
"scope": "ne",
"trust": 0.3,
"vendor": "siemens",
"version": "79.0"
},
{
"model": "simatic pcs sp-1",
"scope": "ne",
"trust": 0.3,
"vendor": "siemens",
"version": "78.2"
},
{
"model": "simatic pcs siemens simatic wincc",
"scope": "eq",
"trust": 0.2,
"vendor": "siemens",
"version": "7\u003c=v8.0\u003c=v7.2"
},
{
"model": "simatic wincc siemens simatic wincc professional (tia portal siemens simatic wincc professional (tia portal siemens simatic w",
"scope": "eq",
"trust": 0.2,
"vendor": "siemens",
"version": "v7.4v15)v14)"
},
{
"model": "simatic wincc runtime professional siemens simatic wincc",
"scope": "eq",
"trust": 0.2,
"vendor": "siemens",
"version": "v15v7.5"
}
],
"sources": [
{
"db": "IVD",
"id": "69364700-0a59-4c18-a969-e06b68873d4f"
},
{
"db": "CNVD",
"id": "CNVD-2019-22244"
},
{
"db": "BID",
"id": "109127"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-006590"
},
{
"db": "NVD",
"id": "CVE-2019-10935"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:a:siemens:simatic_pcs_7:8.2:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:simatic_pcs_7:8.0:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:simatic_pcs_7:8.1:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:simatic_pcs_7:9.0:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:a:siemens:simatic_wincc:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "7.2",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:simatic_wincc:7.3:-:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:simatic_wincc:7.3:update_4:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:simatic_wincc:7.3:update_1:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:simatic_wincc:7.4:sp1:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:simatic_wincc:7.4:update_1:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:simatic_wincc:7.5:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:simatic_wincc:7.3:update_11:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:simatic_wincc:7.4:-:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:simatic_wincc:7.3:update_10:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:simatic_wincc:7.3:update_13:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:a:siemens:simatic_wincc:14:sp1:*:*:professional:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:simatic_wincc:15:*:*:*:professional:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:simatic_wincc:13:-:*:*:professional:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:simatic_wincc:14:*:*:*:professional:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:simatic_wincc:13:sp2:*:*:professional:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:simatic_wincc:14:-:*:*:professional:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:a:siemens:simatic_wincc_runtime:13:-:*:*:professional:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:simatic_wincc_runtime:14:-:*:*:professional:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:simatic_wincc_runtime:14:sp1:*:*:professional:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:simatic_wincc_runtime:15:-:*:*:professional:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:simatic_wincc_runtime:15:update_4:*:*:professional:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:simatic_wincc_runtime:15.1:-:*:*:professional:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:simatic_wincc_runtime:13:sp1:update_9:*:professional:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:simatic_wincc_runtime:13:*:*:*:professional:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:simatic_wincc_runtime:13:sp1:update_2:*:professional:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:simatic_wincc_runtime:13:sp2:*:*:professional:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:simatic_wincc_runtime:15.1:update_1:*:*:professional:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2019-10935"
}
]
},
"credits": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/credits#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Xuchen Zhu from ZheJiang Guoli Security Technology CNCERT/CC",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201907-609"
}
],
"trust": 0.6
},
"cve": "CVE-2019-10935",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"acInsufInfo": false,
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"author": "NVD",
"availabilityImpact": "PARTIAL",
"baseScore": 6.5,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 8.0,
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "MEDIUM",
"trust": 1.0,
"userInteractionRequired": false,
"vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
"version": "2.0"
},
{
"acInsufInfo": null,
"accessComplexity": "Low",
"accessVector": "Network",
"authentication": "Single",
"author": "NVD",
"availabilityImpact": "Partial",
"baseScore": 6.5,
"confidentialityImpact": "Partial",
"exploitabilityScore": null,
"id": "CVE-2019-10935",
"impactScore": null,
"integrityImpact": "Partial",
"obtainAllPrivilege": null,
"obtainOtherPrivilege": null,
"obtainUserPrivilege": null,
"severity": "Medium",
"trust": 0.9,
"userInteractionRequired": null,
"vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 10.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 10.0,
"id": "CNVD-2019-22244",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "IVD",
"availabilityImpact": "COMPLETE",
"baseScore": 10.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 10.0,
"id": "69364700-0a59-4c18-a969-e06b68873d4f",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.2,
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.9 [IVD]"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"author": "VULHUB",
"availabilityImpact": "PARTIAL",
"baseScore": 6.5,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 8.0,
"id": "VHN-142531",
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"severity": "MEDIUM",
"trust": 0.1,
"vectorString": "AV:N/AC:L/AU:S/C:P/I:P/A:P",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "NVD",
"availabilityImpact": "HIGH",
"baseScore": 7.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 1.2,
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 7.2,
"baseSeverity": "High",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "CVE-2019-10935",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "High",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2019-10935",
"trust": 1.8,
"value": "HIGH"
},
{
"author": "CNVD",
"id": "CNVD-2019-22244",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "CNNVD",
"id": "CNNVD-201907-609",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "IVD",
"id": "69364700-0a59-4c18-a969-e06b68873d4f",
"trust": 0.2,
"value": "HIGH"
},
{
"author": "VULHUB",
"id": "VHN-142531",
"trust": 0.1,
"value": "MEDIUM"
},
{
"author": "VULMON",
"id": "CVE-2019-10935",
"trust": 0.1,
"value": "MEDIUM"
}
]
}
],
"sources": [
{
"db": "IVD",
"id": "69364700-0a59-4c18-a969-e06b68873d4f"
},
{
"db": "CNVD",
"id": "CNVD-2019-22244"
},
{
"db": "VULHUB",
"id": "VHN-142531"
},
{
"db": "VULMON",
"id": "CVE-2019-10935"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-006590"
},
{
"db": "NVD",
"id": "CVE-2019-10935"
},
{
"db": "CNNVD",
"id": "CNNVD-201907-609"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "A vulnerability has been identified in SIMATIC PCS 7 V8.0 and earlier (All versions), SIMATIC PCS 7 V8.1 (All versions \u003c V8.1 with WinCC V7.3 Upd 19), SIMATIC PCS 7 V8.2 (All versions \u003c V8.2 SP1 with WinCC V7.4 SP1 Upd 11), SIMATIC PCS 7 V9.0 (All versions \u003c V9.0 SP2 with WinCC V7.4 SP1 Upd11), SIMATIC WinCC Professional (TIA Portal V13) (All versions), SIMATIC WinCC Professional (TIA Portal V14) (All versions \u003c V14 SP1 Upd 9), SIMATIC WinCC Professional (TIA Portal V15) (All versions \u003c V15.1 Upd 3), SIMATIC WinCC Runtime Professional V13 (All versions), SIMATIC WinCC Runtime Professional V14 (All versions \u003c V14.1 Upd 8), SIMATIC WinCC Runtime Professional V15 (All versions \u003c V15.1 Upd 3), SIMATIC WinCC V7.2 and earlier (All versions), SIMATIC WinCC V7.3 (All versions \u003c V7.3 Upd 19), SIMATIC WinCC V7.4 (All versions \u003c V7.4 SP1 Upd 11), SIMATIC WinCC V7.5 (All versions \u003c V7.5 Upd 3). The SIMATIC WinCC DataMonitor web application of the affected products allows to upload arbitrary ASPX code. The security vulnerability could be exploited by an authenticated attacker with network access to the WinCC DataMonitor application. No user interaction is required to exploit this vulnerability. The vulnerability impacts confidentiality, integrity, and availability of the affected device. At the stage of publishing this security advisory no public exploitation is known. plural SIMATIC The product contains a vulnerability related to unlimited uploads of dangerous types of files.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. Siemens SIMATIC PCS 7 and SIMATIC WinCC are products of Siemens AG, Germany. SIMATIC PCS 7 is a process control system. SIMATIC WinCC is an automated data acquisition and monitoring (SCADA) system. The SIMATIC WinCC DataMonitor web is one of the data analysis and display components. \n\nA security vulnerability exists in the SIMATIC WinCC DataMonitor web in several Siemens products. Siemens SIMATIC WinCC and SIMATIC PCS 7 are prone to an arbitrary file-upload vulnerability",
"sources": [
{
"db": "NVD",
"id": "CVE-2019-10935"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-006590"
},
{
"db": "CNVD",
"id": "CNVD-2019-22244"
},
{
"db": "BID",
"id": "109127"
},
{
"db": "IVD",
"id": "69364700-0a59-4c18-a969-e06b68873d4f"
},
{
"db": "VULHUB",
"id": "VHN-142531"
},
{
"db": "VULMON",
"id": "CVE-2019-10935"
}
],
"trust": 2.79
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2019-10935",
"trust": 2.9
},
{
"db": "SIEMENS",
"id": "SSA-121293",
"trust": 2.4
},
{
"db": "ICS CERT",
"id": "ICSA-19-192-02",
"trust": 1.7
},
{
"db": "BID",
"id": "109127",
"trust": 1.1
},
{
"db": "CNVD",
"id": "CNVD-2019-22244",
"trust": 0.8
},
{
"db": "JVNDB",
"id": "JVNDB-2019-006590",
"trust": 0.8
},
{
"db": "CNNVD",
"id": "CNNVD-201907-609",
"trust": 0.7
},
{
"db": "AUSCERT",
"id": "ESB-2019.2574",
"trust": 0.6
},
{
"db": "IVD",
"id": "69364700-0A59-4C18-A969-E06B68873D4F",
"trust": 0.2
},
{
"db": "VULHUB",
"id": "VHN-142531",
"trust": 0.1
},
{
"db": "VULMON",
"id": "CVE-2019-10935",
"trust": 0.1
}
],
"sources": [
{
"db": "IVD",
"id": "69364700-0a59-4c18-a969-e06b68873d4f"
},
{
"db": "CNVD",
"id": "CNVD-2019-22244"
},
{
"db": "VULHUB",
"id": "VHN-142531"
},
{
"db": "VULMON",
"id": "CVE-2019-10935"
},
{
"db": "BID",
"id": "109127"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-006590"
},
{
"db": "NVD",
"id": "CVE-2019-10935"
},
{
"db": "CNNVD",
"id": "CNNVD-201907-609"
}
]
},
"id": "VAR-201907-1455",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "IVD",
"id": "69364700-0a59-4c18-a969-e06b68873d4f"
},
{
"db": "CNVD",
"id": "CNVD-2019-22244"
},
{
"db": "VULHUB",
"id": "VHN-142531"
}
],
"trust": 1.589081636
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"ICS"
],
"sub_category": null,
"trust": 0.8
}
],
"sources": [
{
"db": "IVD",
"id": "69364700-0a59-4c18-a969-e06b68873d4f"
},
{
"db": "CNVD",
"id": "CNVD-2019-22244"
}
]
},
"last_update_date": "2023-12-18T13:18:40.068000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "SSA-121293",
"trust": 0.8,
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-121293.pdf"
},
{
"title": "Patch for Multiple Siemens product code upload vulnerabilities",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchinfo/show/168509"
},
{
"title": "Siemens Security Advisories: Siemens Security Advisory",
"trust": 0.1,
"url": "https://vulmon.com/vendoradvisory?qidtp=siemens_security_advisories\u0026qid=9f83ea9c05726639cd4642c3972ec527"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2019-22244"
},
{
"db": "VULMON",
"id": "CVE-2019-10935"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-006590"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-434",
"trust": 1.9
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-142531"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-006590"
},
{
"db": "NVD",
"id": "CVE-2019-10935"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.4,
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-121293.pdf"
},
{
"trust": 1.7,
"url": "https://www.us-cert.gov/ics/advisories/icsa-19-192-02"
},
{
"trust": 1.4,
"url": "https://nvd.nist.gov/vuln/detail/cve-2019-10935"
},
{
"trust": 1.3,
"url": "https://www.securityfocus.com/bid/109127"
},
{
"trust": 0.9,
"url": "http://subscriber.communications.siemens.com/"
},
{
"trust": 0.9,
"url": "https://new.siemens.com/global/en/products/services/cert.html#securitypublications"
},
{
"trust": 0.8,
"url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2019-10935"
},
{
"trust": 0.6,
"url": "https://www.auscert.org.au/bulletins/esb-2019.2574/"
},
{
"trust": 0.6,
"url": "https://vigilance.fr/vulnerability/siemens-simatic-pcs7-wincc-file-upload-via-datamonitor-29733"
},
{
"trust": 0.1,
"url": "https://cwe.mitre.org/data/definitions/434.html"
},
{
"trust": 0.1,
"url": "https://nvd.nist.gov"
},
{
"trust": 0.1,
"url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/163660"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2019-22244"
},
{
"db": "VULHUB",
"id": "VHN-142531"
},
{
"db": "VULMON",
"id": "CVE-2019-10935"
},
{
"db": "BID",
"id": "109127"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-006590"
},
{
"db": "NVD",
"id": "CVE-2019-10935"
},
{
"db": "CNNVD",
"id": "CNNVD-201907-609"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "IVD",
"id": "69364700-0a59-4c18-a969-e06b68873d4f"
},
{
"db": "CNVD",
"id": "CNVD-2019-22244"
},
{
"db": "VULHUB",
"id": "VHN-142531"
},
{
"db": "VULMON",
"id": "CVE-2019-10935"
},
{
"db": "BID",
"id": "109127"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-006590"
},
{
"db": "NVD",
"id": "CVE-2019-10935"
},
{
"db": "CNNVD",
"id": "CNNVD-201907-609"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2019-07-12T00:00:00",
"db": "IVD",
"id": "69364700-0a59-4c18-a969-e06b68873d4f"
},
{
"date": "2019-07-12T00:00:00",
"db": "CNVD",
"id": "CNVD-2019-22244"
},
{
"date": "2019-07-11T00:00:00",
"db": "VULHUB",
"id": "VHN-142531"
},
{
"date": "2019-07-11T00:00:00",
"db": "VULMON",
"id": "CVE-2019-10935"
},
{
"date": "2019-07-09T00:00:00",
"db": "BID",
"id": "109127"
},
{
"date": "2019-07-24T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2019-006590"
},
{
"date": "2019-07-11T22:15:11.797000",
"db": "NVD",
"id": "CVE-2019-10935"
},
{
"date": "2019-07-10T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201907-609"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2019-10-15T00:00:00",
"db": "CNVD",
"id": "CNVD-2019-22244"
},
{
"date": "2019-10-10T00:00:00",
"db": "VULHUB",
"id": "VHN-142531"
},
{
"date": "2019-10-10T00:00:00",
"db": "VULMON",
"id": "CVE-2019-10935"
},
{
"date": "2019-07-09T00:00:00",
"db": "BID",
"id": "109127"
},
{
"date": "2019-07-24T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2019-006590"
},
{
"date": "2019-10-10T14:15:14.580000",
"db": "NVD",
"id": "CVE-2019-10935"
},
{
"date": "2019-10-14T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201907-609"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201907-609"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "plural SIMATIC Product unrestricted upload vulnerability",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2019-006590"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "code problem",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201907-609"
}
],
"trust": 0.6
}
}
VAR-202306-0965
Vulnerability from variot - Updated: 2023-12-18 13:16A vulnerability has been identified in SIMATIC WinCC (All versions < V7.5.2.13). Affected applications fail to set proper access rights for their installation folder if a non-default installation path was chosen during installation.
This could allow an authenticated local attacker to inject arbitrary code and escalate privileges. SIMATIC WinCC is a supervisory control and data acquisition (SCADA) system
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202306-0965",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "wincc",
"scope": "lt",
"trust": 1.0,
"vendor": "siemens",
"version": "7.5.2.13"
},
{
"model": "simatic wincc",
"scope": "lt",
"trust": 0.6,
"vendor": "siemens",
"version": "7.5.2.13"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2023-48549"
},
{
"db": "NVD",
"id": "CVE-2023-30897"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:a:siemens:wincc:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "7.5.2.13",
"vulnerable": true
}
],
"operator": "OR"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2023-30897"
}
]
},
"cve": "CVE-2023-30897",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "LOCAL",
"authentication": "SINGLE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 6.8,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 3.1,
"id": "CNVD-2023-48549",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "MEDIUM",
"trust": 0.6,
"vectorString": "AV:L/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"author": "NVD",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 1.8,
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"trust": 2.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2023-30897",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "productcert@siemens.com",
"id": "CVE-2023-30897",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "CNVD",
"id": "CNVD-2023-48549",
"trust": 0.6,
"value": "MEDIUM"
},
{
"author": "CNNVD",
"id": "CNNVD-202306-880",
"trust": 0.6,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2023-48549"
},
{
"db": "NVD",
"id": "CVE-2023-30897"
},
{
"db": "NVD",
"id": "CVE-2023-30897"
},
{
"db": "CNNVD",
"id": "CNNVD-202306-880"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "A vulnerability has been identified in SIMATIC WinCC (All versions \u003c V7.5.2.13). Affected applications fail to set proper access rights for their installation folder if a non-default installation path was chosen during installation. \r\n\r\nThis could allow an authenticated local attacker to inject arbitrary code and escalate privileges. SIMATIC WinCC is a supervisory control and data acquisition (SCADA) system",
"sources": [
{
"db": "NVD",
"id": "CVE-2023-30897"
},
{
"db": "CNVD",
"id": "CNVD-2023-48549"
},
{
"db": "VULMON",
"id": "CVE-2023-30897"
}
],
"trust": 1.53
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2023-30897",
"trust": 2.3
},
{
"db": "SIEMENS",
"id": "SSA-914026",
"trust": 2.3
},
{
"db": "CNVD",
"id": "CNVD-2023-48549",
"trust": 0.6
},
{
"db": "CNNVD",
"id": "CNNVD-202306-880",
"trust": 0.6
},
{
"db": "VULMON",
"id": "CVE-2023-30897",
"trust": 0.1
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2023-48549"
},
{
"db": "VULMON",
"id": "CVE-2023-30897"
},
{
"db": "NVD",
"id": "CVE-2023-30897"
},
{
"db": "CNNVD",
"id": "CNNVD-202306-880"
}
]
},
"id": "VAR-202306-0965",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2023-48549"
}
],
"trust": 1.181947215
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"ICS"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2023-48549"
}
]
},
"last_update_date": "2023-12-18T13:16:38.895000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Patch for Siemens SIMATIC WinCC Native Code Execution Vulnerability",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchinfo/show/433506"
},
{
"title": "Siemens SIMATIC WinCC Security vulnerabilities",
"trust": 0.6,
"url": "http://123.124.177.30/web/xxk/bdxqbyid.tag?id=243027"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2023-48549"
},
{
"db": "CNNVD",
"id": "CNNVD-202306-880"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-732",
"trust": 1.0
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2023-30897"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.7,
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-914026.pdf"
},
{
"trust": 0.6,
"url": "https://cert-portal.siemens.com/productcert/html/ssa-914026.html"
},
{
"trust": 0.6,
"url": "https://cxsecurity.com/cveshow/cve-2023-30897/"
},
{
"trust": 0.1,
"url": "https://nvd.nist.gov"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2023-48549"
},
{
"db": "VULMON",
"id": "CVE-2023-30897"
},
{
"db": "NVD",
"id": "CVE-2023-30897"
},
{
"db": "CNNVD",
"id": "CNNVD-202306-880"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2023-48549"
},
{
"db": "VULMON",
"id": "CVE-2023-30897"
},
{
"db": "NVD",
"id": "CVE-2023-30897"
},
{
"db": "CNNVD",
"id": "CNNVD-202306-880"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2023-06-14T00:00:00",
"db": "CNVD",
"id": "CNVD-2023-48549"
},
{
"date": "2023-06-13T00:00:00",
"db": "VULMON",
"id": "CVE-2023-30897"
},
{
"date": "2023-06-13T09:15:17.703000",
"db": "NVD",
"id": "CVE-2023-30897"
},
{
"date": "2023-06-13T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202306-880"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2023-06-14T00:00:00",
"db": "CNVD",
"id": "CNVD-2023-48549"
},
{
"date": "2023-06-13T00:00:00",
"db": "VULMON",
"id": "CVE-2023-30897"
},
{
"date": "2023-06-26T17:41:04.607000",
"db": "NVD",
"id": "CVE-2023-30897"
},
{
"date": "2023-06-27T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202306-880"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "local",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202306-880"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Siemens SIMATIC WinCC Native Code Execution Vulnerability",
"sources": [
{
"db": "CNVD",
"id": "CNVD-2023-48549"
}
],
"trust": 0.6
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "other",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202306-880"
}
],
"trust": 0.6
}
}
VAR-201607-0466
Vulnerability from variot - Updated: 2023-12-18 13:14Siemens SIMATIC WinCC 7.0 through SP3 and 7.2 allows remote attackers to read arbitrary WinCC station files via crafted packets. The SIMATIC WinCC (Windows Control Center) window control center is Siemens' process monitoring system, providing complete monitoring and data acquisition (SCADA) functions for the industrial sector. The SIMATIC WinCC presence file contains a vulnerability. Successful exploits may allow an attacker to read arbitrary files in the context of the user running the affected application. This may aid in further attacks. Siemens SIMATIC WinCC is a set of automatic data acquisition and monitoring (SCADA) system of German Siemens (Siemens). A security vulnerability exists in Siemens SIMATIC WinCC versions 7.0 to SP3 and 7.2
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-201607-0466",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "simatic wincc",
"scope": "eq",
"trust": 3.3,
"vendor": "siemens",
"version": "7.2"
},
{
"model": "simatic wincc",
"scope": "eq",
"trust": 2.5,
"vendor": "siemens",
"version": "7.0"
},
{
"model": null,
"scope": "eq",
"trust": 0.8,
"vendor": "simatic wincc",
"version": "7.0"
},
{
"model": "simatic wincc",
"scope": "eq",
"trust": 0.8,
"vendor": "siemens",
"version": "7.0 sp3 for up to 7.0"
},
{
"model": "simatic wincc update",
"scope": "ne",
"trust": 0.3,
"vendor": "siemens",
"version": "7.41"
},
{
"model": "simatic wincc update",
"scope": "ne",
"trust": 0.3,
"vendor": "siemens",
"version": "7.310"
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "simatic wincc",
"version": "7.2"
}
],
"sources": [
{
"db": "IVD",
"id": "c953b84a-1100-47f7-a149-3e8bdff937c4"
},
{
"db": "CNVD",
"id": "CNVD-2016-05345"
},
{
"db": "BID",
"id": "92116"
},
{
"db": "JVNDB",
"id": "JVNDB-2016-004096"
},
{
"db": "NVD",
"id": "CVE-2016-5744"
},
{
"db": "CNNVD",
"id": "CNNVD-201607-905"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:a:siemens:simatic_wincc:7.2:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:simatic_wincc:7.0:sp3:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:simatic_wincc:7.0:sp2:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:simatic_wincc:7.0:sp1:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:simatic_wincc:7.0:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2016-5744"
}
]
},
"credits": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/credits#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Sergey Temnikov and Vladimir Dashchenko, Critical Infrastructure Defence\nTeam, Kaspersky Lab.",
"sources": [
{
"db": "BID",
"id": "92116"
}
],
"trust": 0.3
},
"cve": "CVE-2016-5744",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"acInsufInfo": true,
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "NVD",
"availabilityImpact": "NONE",
"baseScore": 5.0,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 10.0,
"impactScore": 2.9,
"integrityImpact": "NONE",
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "MEDIUM",
"trust": 1.0,
"userInteractionRequired": false,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
"version": "2.0"
},
{
"acInsufInfo": null,
"accessComplexity": "Low",
"accessVector": "Network",
"authentication": "None",
"author": "NVD",
"availabilityImpact": "None",
"baseScore": 5.0,
"confidentialityImpact": "Partial",
"exploitabilityScore": null,
"id": "CVE-2016-5744",
"impactScore": null,
"integrityImpact": "None",
"obtainAllPrivilege": null,
"obtainOtherPrivilege": null,
"obtainUserPrivilege": null,
"severity": "Medium",
"trust": 0.8,
"userInteractionRequired": null,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "NONE",
"baseScore": 7.8,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 10.0,
"id": "CNVD-2016-05345",
"impactScore": 6.9,
"integrityImpact": "NONE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:C/I:N/A:N",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "IVD",
"availabilityImpact": "NONE",
"baseScore": 7.8,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 10.0,
"id": "c953b84a-1100-47f7-a149-3e8bdff937c4",
"impactScore": 6.9,
"integrityImpact": "NONE",
"severity": "HIGH",
"trust": 0.2,
"vectorString": "AV:N/AC:L/Au:N/C:C/I:N/A:N",
"version": "2.9 [IVD]"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "VULHUB",
"availabilityImpact": "NONE",
"baseScore": 5.0,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 10.0,
"id": "VHN-94563",
"impactScore": 2.9,
"integrityImpact": "NONE",
"severity": "MEDIUM",
"trust": 0.1,
"vectorString": "AV:N/AC:L/AU:N/C:P/I:N/A:N",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "NVD",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 3.9,
"impactScore": 3.6,
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.0"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "None",
"baseScore": 7.5,
"baseSeverity": "High",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "CVE-2016-5744",
"impactScore": null,
"integrityImpact": "None",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.0"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2016-5744",
"trust": 1.8,
"value": "HIGH"
},
{
"author": "CNVD",
"id": "CNVD-2016-05345",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "CNNVD",
"id": "CNNVD-201607-905",
"trust": 0.6,
"value": "MEDIUM"
},
{
"author": "IVD",
"id": "c953b84a-1100-47f7-a149-3e8bdff937c4",
"trust": 0.2,
"value": "MEDIUM"
},
{
"author": "VULHUB",
"id": "VHN-94563",
"trust": 0.1,
"value": "MEDIUM"
}
]
}
],
"sources": [
{
"db": "IVD",
"id": "c953b84a-1100-47f7-a149-3e8bdff937c4"
},
{
"db": "CNVD",
"id": "CNVD-2016-05345"
},
{
"db": "VULHUB",
"id": "VHN-94563"
},
{
"db": "JVNDB",
"id": "JVNDB-2016-004096"
},
{
"db": "NVD",
"id": "CVE-2016-5744"
},
{
"db": "CNNVD",
"id": "CNNVD-201607-905"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Siemens SIMATIC WinCC 7.0 through SP3 and 7.2 allows remote attackers to read arbitrary WinCC station files via crafted packets. The SIMATIC WinCC (Windows Control Center) window control center is Siemens\u0027 process monitoring system, providing complete monitoring and data acquisition (SCADA) functions for the industrial sector. The SIMATIC WinCC presence file contains a vulnerability. \nSuccessful exploits may allow an attacker to read arbitrary files in the context of the user running the affected application. This may aid in further attacks. Siemens SIMATIC WinCC is a set of automatic data acquisition and monitoring (SCADA) system of German Siemens (Siemens). A security vulnerability exists in Siemens SIMATIC WinCC versions 7.0 to SP3 and 7.2",
"sources": [
{
"db": "NVD",
"id": "CVE-2016-5744"
},
{
"db": "JVNDB",
"id": "JVNDB-2016-004096"
},
{
"db": "CNVD",
"id": "CNVD-2016-05345"
},
{
"db": "BID",
"id": "92116"
},
{
"db": "IVD",
"id": "c953b84a-1100-47f7-a149-3e8bdff937c4"
},
{
"db": "VULHUB",
"id": "VHN-94563"
}
],
"trust": 2.7
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2016-5744",
"trust": 3.6
},
{
"db": "SIEMENS",
"id": "SSA-378531",
"trust": 2.6
},
{
"db": "ICS CERT",
"id": "ICSA-16-208-01",
"trust": 2.2
},
{
"db": "BID",
"id": "92116",
"trust": 2.0
},
{
"db": "SECTRACK",
"id": "1036441",
"trust": 1.1
},
{
"db": "CNNVD",
"id": "CNNVD-201607-905",
"trust": 0.9
},
{
"db": "CNVD",
"id": "CNVD-2016-05345",
"trust": 0.8
},
{
"db": "JVNDB",
"id": "JVNDB-2016-004096",
"trust": 0.8
},
{
"db": "IVD",
"id": "C953B84A-1100-47F7-A149-3E8BDFF937C4",
"trust": 0.2
},
{
"db": "VULHUB",
"id": "VHN-94563",
"trust": 0.1
}
],
"sources": [
{
"db": "IVD",
"id": "c953b84a-1100-47f7-a149-3e8bdff937c4"
},
{
"db": "CNVD",
"id": "CNVD-2016-05345"
},
{
"db": "VULHUB",
"id": "VHN-94563"
},
{
"db": "BID",
"id": "92116"
},
{
"db": "JVNDB",
"id": "JVNDB-2016-004096"
},
{
"db": "NVD",
"id": "CVE-2016-5744"
},
{
"db": "CNNVD",
"id": "CNNVD-201607-905"
}
]
},
"id": "VAR-201607-0466",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "IVD",
"id": "c953b84a-1100-47f7-a149-3e8bdff937c4"
},
{
"db": "CNVD",
"id": "CNVD-2016-05345"
},
{
"db": "VULHUB",
"id": "VHN-94563"
}
],
"trust": 1.5491014650000001
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"ICS"
],
"sub_category": null,
"trust": 0.8
}
],
"sources": [
{
"db": "IVD",
"id": "c953b84a-1100-47f7-a149-3e8bdff937c4"
},
{
"db": "CNVD",
"id": "CNVD-2016-05345"
}
]
},
"last_update_date": "2023-12-18T13:14:28.604000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "SSA-378531",
"trust": 0.8,
"url": "http://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-378531.pdf"
},
{
"title": "The SIMATIC WinCC presence file contains a patch for the vulnerability",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchinfo/show/79587"
},
{
"title": "Siemens SIMATIC WinCC Security vulnerabilities",
"trust": 0.6,
"url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=63265"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2016-05345"
},
{
"db": "JVNDB",
"id": "JVNDB-2016-004096"
},
{
"db": "CNNVD",
"id": "CNNVD-201607-905"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-200",
"trust": 1.9
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-94563"
},
{
"db": "JVNDB",
"id": "JVNDB-2016-004096"
},
{
"db": "NVD",
"id": "CVE-2016-5744"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.6,
"url": "http://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-378531.pdf"
},
{
"trust": 2.2,
"url": "https://ics-cert.us-cert.gov/advisories/icsa-16-208-01"
},
{
"trust": 1.1,
"url": "http://www.securityfocus.com/bid/92116"
},
{
"trust": 1.1,
"url": "http://www.securitytracker.com/id/1036441"
},
{
"trust": 0.8,
"url": "http://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2016-5744"
},
{
"trust": 0.8,
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnid=cve-2016-5744"
},
{
"trust": 0.3,
"url": "http://subscriber.communications.siemens.com/"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2016-05345"
},
{
"db": "VULHUB",
"id": "VHN-94563"
},
{
"db": "BID",
"id": "92116"
},
{
"db": "JVNDB",
"id": "JVNDB-2016-004096"
},
{
"db": "NVD",
"id": "CVE-2016-5744"
},
{
"db": "CNNVD",
"id": "CNNVD-201607-905"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "IVD",
"id": "c953b84a-1100-47f7-a149-3e8bdff937c4"
},
{
"db": "CNVD",
"id": "CNVD-2016-05345"
},
{
"db": "VULHUB",
"id": "VHN-94563"
},
{
"db": "BID",
"id": "92116"
},
{
"db": "JVNDB",
"id": "JVNDB-2016-004096"
},
{
"db": "NVD",
"id": "CVE-2016-5744"
},
{
"db": "CNNVD",
"id": "CNNVD-201607-905"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2016-07-25T00:00:00",
"db": "IVD",
"id": "c953b84a-1100-47f7-a149-3e8bdff937c4"
},
{
"date": "2016-07-25T00:00:00",
"db": "CNVD",
"id": "CNVD-2016-05345"
},
{
"date": "2016-07-22T00:00:00",
"db": "VULHUB",
"id": "VHN-94563"
},
{
"date": "2016-07-25T00:00:00",
"db": "BID",
"id": "92116"
},
{
"date": "2016-08-01T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2016-004096"
},
{
"date": "2016-07-22T15:59:01.397000",
"db": "NVD",
"id": "CVE-2016-5744"
},
{
"date": "2016-07-25T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201607-905"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2016-07-25T00:00:00",
"db": "CNVD",
"id": "CNVD-2016-05345"
},
{
"date": "2016-11-28T00:00:00",
"db": "VULHUB",
"id": "VHN-94563"
},
{
"date": "2016-07-25T00:00:00",
"db": "BID",
"id": "92116"
},
{
"date": "2016-08-01T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2016-004096"
},
{
"date": "2016-11-28T20:29:10.953000",
"db": "NVD",
"id": "CVE-2016-5744"
},
{
"date": "2016-07-25T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201607-905"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201607-905"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Siemens SIMATIC WinCC In any WinCC Vulnerability in reading station files",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2016-004096"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "information disclosure",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201607-905"
}
],
"trust": 0.6
}
}
VAR-201607-0465
Vulnerability from variot - Updated: 2023-12-18 13:14Siemens SIMATIC WinCC before 7.3 Update 10 and 7.4 before Update 1, SIMATIC BATCH before 8.1 SP1 Update 9 as distributed in SIMATIC PCS 7 through 8.1 SP1, SIMATIC OpenPCS 7 before 8.1 Update 3 as distributed in SIMATIC PCS 7 through 8.1 SP1, SIMATIC OpenPCS 7 before 8.2 Update 1 as distributed in SIMATIC PCS 7 8.2, and SIMATIC WinCC Runtime Professional before 13 SP1 Update 9 allow remote attackers to execute arbitrary code via crafted packets. The SIMATIC WinCC (Windows Control Center) window control center is Siemens' process monitoring system, providing complete monitoring and data acquisition (SCADA) functions for the industrial sector; the PCS 7 system is a seamlessly integrated automation solution for all industrial applications. field. A remote code execution vulnerability exists in SIMATIC WinCC/PCS 7/WinCC Runtime Professional. Multiple Siemens Products are prone to a remote code-execution vulnerability. An attacker can exploit this issue to inject and execute arbitrary code in the context of the affected application. Siemens SIMATIC WinCC, etc. are all industrial automation products of Siemens (Siemens) in Germany
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-201607-0465",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "simatic openpcs 7",
"scope": "lte",
"trust": 1.0,
"vendor": "siemens",
"version": "8.2"
},
{
"model": "simatic batch",
"scope": "lte",
"trust": 1.0,
"vendor": "siemens",
"version": "7.1"
},
{
"model": "simatic openpcs 7",
"scope": "lte",
"trust": 1.0,
"vendor": "siemens",
"version": "8.1"
},
{
"model": "simatic wincc",
"scope": "lte",
"trust": 1.0,
"vendor": "siemens",
"version": "7.4"
},
{
"model": "simatic wincc",
"scope": "lte",
"trust": 1.0,
"vendor": "siemens",
"version": "7.3"
},
{
"model": "simatic pcs",
"scope": "eq",
"trust": 0.9,
"vendor": "siemens",
"version": "78.0"
},
{
"model": "simatic pcs",
"scope": "eq",
"trust": 0.9,
"vendor": "siemens",
"version": "78.1"
},
{
"model": "simatic pcs",
"scope": "eq",
"trust": 0.9,
"vendor": "siemens",
"version": "78.2"
},
{
"model": "simatic wincc sp",
"scope": "eq",
"trust": 0.9,
"vendor": "siemens",
"version": "7.03"
},
{
"model": "simatic wincc",
"scope": "eq",
"trust": 0.9,
"vendor": "siemens",
"version": "7.2"
},
{
"model": "simatic wincc",
"scope": "eq",
"trust": 0.9,
"vendor": "siemens",
"version": "7.4"
},
{
"model": "simatic wincc",
"scope": "eq",
"trust": 0.9,
"vendor": "siemens",
"version": "7.3"
},
{
"model": "simatic wincc",
"scope": "eq",
"trust": 0.8,
"vendor": "siemens",
"version": "7.4 update 1"
},
{
"model": "simatic wincc",
"scope": "lt",
"trust": 0.8,
"vendor": "siemens",
"version": "7.4"
},
{
"model": "simatic pcs sp4",
"scope": "eq",
"trust": 0.6,
"vendor": "siemens",
"version": "7\u003c=7.1"
},
{
"model": "simatic wincc runtime professional sp update",
"scope": "lt",
"trust": 0.6,
"vendor": "siemens",
"version": "v1319"
},
{
"model": "simatic wincc sp",
"scope": "lte",
"trust": 0.6,
"vendor": "siemens",
"version": "\u003c=7.02"
},
{
"model": "simatic wincc update",
"scope": "eq",
"trust": 0.6,
"vendor": "siemens",
"version": "7.3x\u003c7.310"
},
{
"model": "simatic wincc update",
"scope": "eq",
"trust": 0.6,
"vendor": "siemens",
"version": "7.4x\u003c7.41"
},
{
"model": "simatic openpcs 7",
"scope": "eq",
"trust": 0.6,
"vendor": "siemens",
"version": "8.1"
},
{
"model": "simatic batch",
"scope": "eq",
"trust": 0.6,
"vendor": "siemens",
"version": "7.1"
},
{
"model": "simatic openpcs 7",
"scope": "eq",
"trust": 0.6,
"vendor": "siemens",
"version": "8.2"
},
{
"model": null,
"scope": "eq",
"trust": 0.4,
"vendor": "simatic wincc",
"version": "*"
},
{
"model": null,
"scope": "eq",
"trust": 0.4,
"vendor": "simatic openpcs 7",
"version": "*"
},
{
"model": "simatic wincc runtime professional sp1 upd2",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "13"
},
{
"model": "simatic wincc runtime professional",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "13"
},
{
"model": "simatic wincc update",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "7.32"
},
{
"model": "simatic wincc update",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "7.31"
},
{
"model": "simatic wincc update",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "7.29"
},
{
"model": "simatic wincc update",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "7.28"
},
{
"model": "simatic wincc update",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "7.21"
},
{
"model": "simatic wincc upd4",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "7.2"
},
{
"model": "simatic wincc upd11",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "7.2"
},
{
"model": "simatic wincc sp",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "7.02"
},
{
"model": "simatic pcs sp4",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "77.1"
},
{
"model": "simatic wincc runtime professional sp update",
"scope": "ne",
"trust": 0.3,
"vendor": "siemens",
"version": "1319"
},
{
"model": "simatic wincc update",
"scope": "ne",
"trust": 0.3,
"vendor": "siemens",
"version": "7.41"
},
{
"model": "simatic wincc update",
"scope": "ne",
"trust": 0.3,
"vendor": "siemens",
"version": "7.310"
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "simatic batch",
"version": "*"
}
],
"sources": [
{
"db": "IVD",
"id": "649ab73e-2968-450b-b5d3-31e462571302"
},
{
"db": "CNVD",
"id": "CNVD-2016-05346"
},
{
"db": "BID",
"id": "92112"
},
{
"db": "JVNDB",
"id": "JVNDB-2016-004095"
},
{
"db": "NVD",
"id": "CVE-2016-5743"
},
{
"db": "CNNVD",
"id": "CNNVD-201607-904"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:a:siemens:simatic_wincc:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "7.4",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:simatic_batch:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "7.1",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:simatic_wincc:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "7.3",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:a:siemens:simatic_pcs_7:*:sp1:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "8.1",
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:a:siemens:simatic_openpcs_7:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "8.1",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:a:siemens:simatic_pcs_7:*:sp1:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "8.1",
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:a:siemens:simatic_openpcs_7:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "8.2",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:a:siemens:simatic_wincc_runtime_professional:*:sp1:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "13",
"vulnerable": false
},
{
"cpe23Uri": "cpe:2.3:a:siemens:simatic_pcs_7:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "8.2",
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2016-5743"
}
]
},
"credits": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/credits#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Sergey Temnikov and Vladimir Dashchenko, Critical Infrastructure Defence\nTeam, Kaspersky Lab.",
"sources": [
{
"db": "BID",
"id": "92112"
}
],
"trust": 0.3
},
"cve": "CVE-2016-5743",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"acInsufInfo": true,
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "NVD",
"availabilityImpact": "COMPLETE",
"baseScore": 10.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 10.0,
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "HIGH",
"trust": 1.0,
"userInteractionRequired": false,
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
},
{
"acInsufInfo": null,
"accessComplexity": "Low",
"accessVector": "Network",
"authentication": "None",
"author": "NVD",
"availabilityImpact": "Complete",
"baseScore": 10.0,
"confidentialityImpact": "Complete",
"exploitabilityScore": null,
"id": "CVE-2016-5743",
"impactScore": null,
"integrityImpact": "Complete",
"obtainAllPrivilege": null,
"obtainOtherPrivilege": null,
"obtainUserPrivilege": null,
"severity": "High",
"trust": 0.8,
"userInteractionRequired": null,
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 10.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 10.0,
"id": "CNVD-2016-05346",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "IVD",
"availabilityImpact": "COMPLETE",
"baseScore": 10.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 10.0,
"id": "649ab73e-2968-450b-b5d3-31e462571302",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.2,
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.9 [IVD]"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "VULHUB",
"availabilityImpact": "COMPLETE",
"baseScore": 10.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 10.0,
"id": "VHN-94562",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.1,
"vectorString": "AV:N/AC:L/AU:N/C:C/I:C/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "NVD",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 9.8,
"baseSeverity": "Critical",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "CVE-2016-5743",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2016-5743",
"trust": 1.8,
"value": "CRITICAL"
},
{
"author": "CNVD",
"id": "CNVD-2016-05346",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "CNNVD",
"id": "CNNVD-201607-904",
"trust": 0.6,
"value": "CRITICAL"
},
{
"author": "IVD",
"id": "649ab73e-2968-450b-b5d3-31e462571302",
"trust": 0.2,
"value": "CRITICAL"
},
{
"author": "VULHUB",
"id": "VHN-94562",
"trust": 0.1,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "IVD",
"id": "649ab73e-2968-450b-b5d3-31e462571302"
},
{
"db": "CNVD",
"id": "CNVD-2016-05346"
},
{
"db": "VULHUB",
"id": "VHN-94562"
},
{
"db": "JVNDB",
"id": "JVNDB-2016-004095"
},
{
"db": "NVD",
"id": "CVE-2016-5743"
},
{
"db": "CNNVD",
"id": "CNNVD-201607-904"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Siemens SIMATIC WinCC before 7.3 Update 10 and 7.4 before Update 1, SIMATIC BATCH before 8.1 SP1 Update 9 as distributed in SIMATIC PCS 7 through 8.1 SP1, SIMATIC OpenPCS 7 before 8.1 Update 3 as distributed in SIMATIC PCS 7 through 8.1 SP1, SIMATIC OpenPCS 7 before 8.2 Update 1 as distributed in SIMATIC PCS 7 8.2, and SIMATIC WinCC Runtime Professional before 13 SP1 Update 9 allow remote attackers to execute arbitrary code via crafted packets. The SIMATIC WinCC (Windows Control Center) window control center is Siemens\u0027 process monitoring system, providing complete monitoring and data acquisition (SCADA) functions for the industrial sector; the PCS 7 system is a seamlessly integrated automation solution for all industrial applications. field. A remote code execution vulnerability exists in SIMATIC WinCC/PCS 7/WinCC Runtime Professional. Multiple Siemens Products are prone to a remote code-execution vulnerability. \nAn attacker can exploit this issue to inject and execute arbitrary code in the context of the affected application. Siemens SIMATIC WinCC, etc. are all industrial automation products of Siemens (Siemens) in Germany",
"sources": [
{
"db": "NVD",
"id": "CVE-2016-5743"
},
{
"db": "JVNDB",
"id": "JVNDB-2016-004095"
},
{
"db": "CNVD",
"id": "CNVD-2016-05346"
},
{
"db": "BID",
"id": "92112"
},
{
"db": "IVD",
"id": "649ab73e-2968-450b-b5d3-31e462571302"
},
{
"db": "VULHUB",
"id": "VHN-94562"
}
],
"trust": 2.7
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2016-5743",
"trust": 3.6
},
{
"db": "SIEMENS",
"id": "SSA-378531",
"trust": 2.6
},
{
"db": "ICS CERT",
"id": "ICSA-16-208-01",
"trust": 2.2
},
{
"db": "BID",
"id": "92112",
"trust": 2.0
},
{
"db": "SECTRACK",
"id": "1036441",
"trust": 1.1
},
{
"db": "CNNVD",
"id": "CNNVD-201607-904",
"trust": 0.9
},
{
"db": "CNVD",
"id": "CNVD-2016-05346",
"trust": 0.8
},
{
"db": "JVNDB",
"id": "JVNDB-2016-004095",
"trust": 0.8
},
{
"db": "IVD",
"id": "649AB73E-2968-450B-B5D3-31E462571302",
"trust": 0.2
},
{
"db": "VULHUB",
"id": "VHN-94562",
"trust": 0.1
}
],
"sources": [
{
"db": "IVD",
"id": "649ab73e-2968-450b-b5d3-31e462571302"
},
{
"db": "CNVD",
"id": "CNVD-2016-05346"
},
{
"db": "VULHUB",
"id": "VHN-94562"
},
{
"db": "BID",
"id": "92112"
},
{
"db": "JVNDB",
"id": "JVNDB-2016-004095"
},
{
"db": "NVD",
"id": "CVE-2016-5743"
},
{
"db": "CNNVD",
"id": "CNNVD-201607-904"
}
]
},
"id": "VAR-201607-0465",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "IVD",
"id": "649ab73e-2968-450b-b5d3-31e462571302"
},
{
"db": "CNVD",
"id": "CNVD-2016-05346"
},
{
"db": "VULHUB",
"id": "VHN-94562"
}
],
"trust": 1.5460884383333333
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"ICS"
],
"sub_category": null,
"trust": 0.8
}
],
"sources": [
{
"db": "IVD",
"id": "649ab73e-2968-450b-b5d3-31e462571302"
},
{
"db": "CNVD",
"id": "CNVD-2016-05346"
}
]
},
"last_update_date": "2023-12-18T13:14:28.684000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "SSA-378531",
"trust": 0.8,
"url": "http://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-378531.pdf"
},
{
"title": "Patch for remote code execution vulnerability in SIMATIC WinCC/PCS 7/WinCCRuntime Professional",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchinfo/show/79586"
},
{
"title": "Multiple Siemens Product security vulnerabilities",
"trust": 0.6,
"url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=63264"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2016-05346"
},
{
"db": "JVNDB",
"id": "JVNDB-2016-004095"
},
{
"db": "CNNVD",
"id": "CNNVD-201607-904"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-20",
"trust": 1.9
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-94562"
},
{
"db": "JVNDB",
"id": "JVNDB-2016-004095"
},
{
"db": "NVD",
"id": "CVE-2016-5743"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.6,
"url": "http://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-378531.pdf"
},
{
"trust": 2.2,
"url": "https://ics-cert.us-cert.gov/advisories/icsa-16-208-01"
},
{
"trust": 1.1,
"url": "http://www.securityfocus.com/bid/92112"
},
{
"trust": 1.1,
"url": "http://www.securitytracker.com/id/1036441"
},
{
"trust": 0.8,
"url": "http://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2016-5743"
},
{
"trust": 0.8,
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnid=cve-2016-5743"
},
{
"trust": 0.3,
"url": "http://www.siemens.com/"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2016-05346"
},
{
"db": "VULHUB",
"id": "VHN-94562"
},
{
"db": "BID",
"id": "92112"
},
{
"db": "JVNDB",
"id": "JVNDB-2016-004095"
},
{
"db": "NVD",
"id": "CVE-2016-5743"
},
{
"db": "CNNVD",
"id": "CNNVD-201607-904"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "IVD",
"id": "649ab73e-2968-450b-b5d3-31e462571302"
},
{
"db": "CNVD",
"id": "CNVD-2016-05346"
},
{
"db": "VULHUB",
"id": "VHN-94562"
},
{
"db": "BID",
"id": "92112"
},
{
"db": "JVNDB",
"id": "JVNDB-2016-004095"
},
{
"db": "NVD",
"id": "CVE-2016-5743"
},
{
"db": "CNNVD",
"id": "CNNVD-201607-904"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2016-07-25T00:00:00",
"db": "IVD",
"id": "649ab73e-2968-450b-b5d3-31e462571302"
},
{
"date": "2016-07-25T00:00:00",
"db": "CNVD",
"id": "CNVD-2016-05346"
},
{
"date": "2016-07-22T00:00:00",
"db": "VULHUB",
"id": "VHN-94562"
},
{
"date": "2016-07-22T00:00:00",
"db": "BID",
"id": "92112"
},
{
"date": "2016-08-01T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2016-004095"
},
{
"date": "2016-07-22T15:59:00.147000",
"db": "NVD",
"id": "CVE-2016-5743"
},
{
"date": "2016-07-25T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201607-904"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2016-07-25T00:00:00",
"db": "CNVD",
"id": "CNVD-2016-05346"
},
{
"date": "2016-11-28T00:00:00",
"db": "VULHUB",
"id": "VHN-94562"
},
{
"date": "2016-07-22T00:00:00",
"db": "BID",
"id": "92112"
},
{
"date": "2016-08-01T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2016-004095"
},
{
"date": "2016-11-28T20:29:09.843000",
"db": "NVD",
"id": "CVE-2016-5743"
},
{
"date": "2016-07-25T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201607-904"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201607-904"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "plural Siemens SIMATIC Vulnerabilities in products that allow arbitrary code execution",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2016-004095"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Input validation",
"sources": [
{
"db": "IVD",
"id": "649ab73e-2968-450b-b5d3-31e462571302"
},
{
"db": "CNNVD",
"id": "CNNVD-201607-904"
}
],
"trust": 0.8
}
}
VAR-201812-0343
Vulnerability from variot - Updated: 2023-12-18 13:13A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V15 Update 4), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions < V15 Update 4), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15 Update 4), SIMATIC WinCC Runtime Advanced (All versions < V15 Update 4), SIMATIC WinCC Runtime Professional (All versions < V15 Update 4), SIMATIC WinCC (TIA Portal) (All versions < V15 Update 4), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). A directory traversal vulnerability could allow to download arbitrary files from the device. The security vulnerability could be exploited by an attacker with network access to the integrated web server. No user interaction and no authentication is required to exploit the vulnerability. The vulnerability impacts the confidentiality of the device. At the time of advisory publication no public exploitation of this security vulnerability was known. plural SIMATIC The product contains a path traversal vulnerability.Information may be obtained. Siemens SIMATIC Panels is prone to following security vulnerabilities: 1. An open-redirection vulnerability 2. A directory-traversal vulnerability Remote attackers may use a specially crafted request with directory-traversal sequences ('../') to retrieve arbitrary files from the affected system in the context of the application or by constructing a crafted URI and enticing a user to follow it and when an unsuspecting victim follows the link, they may be redirected to an attacker-controlled site. are all HMI software used by Siemens in Germany to control and monitor machines and equipment
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-201812-0343",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "simatic hmi ktp mobile panels ktp400f",
"scope": "lte",
"trust": 1.0,
"vendor": "siemens",
"version": "15.0"
},
{
"model": "simatic hmi op",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "*"
},
{
"model": "simatic wincc runtime",
"scope": "lte",
"trust": 1.0,
"vendor": "siemens",
"version": "15.0"
},
{
"model": "simatic wincc \\",
"scope": "lte",
"trust": 1.0,
"vendor": "siemens",
"version": "15.0"
},
{
"model": "simatic hmi comfort panels",
"scope": "lte",
"trust": 1.0,
"vendor": "siemens",
"version": "15.0"
},
{
"model": "simatic hmi tp",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "*"
},
{
"model": "simatic hmi mp",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "*"
},
{
"model": "simatic hmi ktp mobile panels ktp900",
"scope": "lte",
"trust": 1.0,
"vendor": "siemens",
"version": "15.0"
},
{
"model": "simatic hmi comfort outdoor panels",
"scope": "lte",
"trust": 1.0,
"vendor": "siemens",
"version": "15.0"
},
{
"model": "simatic hmi ktp mobile panels ktp700",
"scope": "lte",
"trust": 1.0,
"vendor": "siemens",
"version": "15.0"
},
{
"model": "simatic hmi ktp mobile panels ktp900f",
"scope": "lte",
"trust": 1.0,
"vendor": "siemens",
"version": "15.0"
},
{
"model": "simatic hmi ktp mobile panels ktp700f",
"scope": "lte",
"trust": 1.0,
"vendor": "siemens",
"version": "15.0"
},
{
"model": "simatic hmi comfort outdoor panels",
"scope": null,
"trust": 0.8,
"vendor": "siemens",
"version": null
},
{
"model": "simatic hmi comfort panels",
"scope": null,
"trust": 0.8,
"vendor": "siemens",
"version": null
},
{
"model": "simatic hmi ktp mobile panels ktp400f",
"scope": null,
"trust": 0.8,
"vendor": "siemens",
"version": null
},
{
"model": "simatic hmi ktp mobile panels ktp700",
"scope": null,
"trust": 0.8,
"vendor": "siemens",
"version": null
},
{
"model": "simatic hmi ktp mobile panels ktp700f",
"scope": null,
"trust": 0.8,
"vendor": "siemens",
"version": null
},
{
"model": "simatic hmi ktp mobile panels ktp900",
"scope": null,
"trust": 0.8,
"vendor": "siemens",
"version": null
},
{
"model": "simatic hmi ktp mobile panels ktp900f",
"scope": null,
"trust": 0.8,
"vendor": "siemens",
"version": null
},
{
"model": "simatic wincc",
"scope": null,
"trust": 0.8,
"vendor": "siemens",
"version": null
},
{
"model": "simatic wincc runtime advanced",
"scope": null,
"trust": 0.8,
"vendor": "siemens",
"version": null
},
{
"model": "simatic wincc runtime professional",
"scope": null,
"trust": 0.8,
"vendor": "siemens",
"version": null
},
{
"model": "simatic wincc runtime professional",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "15"
},
{
"model": "simatic wincc runtime professional sp1",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "14"
},
{
"model": "simatic wincc runtime professional",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "14"
},
{
"model": "simatic wincc runtime professional sp2",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "13"
},
{
"model": "simatic wincc runtime professional sp1 upd2",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "13"
},
{
"model": "simatic wincc runtime professional sp update",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "1319"
},
{
"model": "simatic wincc runtime professional",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "13"
},
{
"model": "simatic wincc runtime advanced",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "15"
},
{
"model": "simatic wincc runtime advanced sp1 upd2",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "13"
},
{
"model": "simatic wincc runtime advanced",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "13"
},
{
"model": "simatic wincc runtime advanced sp1 upd5",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "12"
},
{
"model": "simatic wincc runtime advanced",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "12"
},
{
"model": "simatic wincc runtime advanced",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "0"
},
{
"model": "simatic wincc update",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "v135"
},
{
"model": "simatic wincc sp1",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "v12"
},
{
"model": "simatic wincc",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "v120"
},
{
"model": "simatic wincc",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "v110"
},
{
"model": "simatic wincc",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "v15"
},
{
"model": "simatic wincc update",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "v136"
},
{
"model": "simatic wincc sp1",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "v13"
},
{
"model": "simatic wincc",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "v13"
},
{
"model": "simatic wincc",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "v10"
},
{
"model": "simatic hmi ktp mobile panels",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "0"
},
{
"model": "simatic hmi comfort panels",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "4"
},
{
"model": "simatic hmi comfort panels",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "22"
},
{
"model": "simatic hmi comfort panels",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "15"
},
{
"model": "simatic hmi comfort panels sp1 upd2",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "13"
},
{
"model": "simatic hmi comfort panels",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "13"
},
{
"model": "simatic hmi comfort panels sp1 upd5",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "12"
},
{
"model": "simatic hmi comfort panels",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "12"
},
{
"model": "simatic hmi comfort panels",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "0"
},
{
"model": "simatic hmi comfort outdoor panels",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "0"
},
{
"model": "simatic hmi classic devices",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "0"
},
{
"model": "simatic wincc runtime professional update",
"scope": "ne",
"trust": 0.3,
"vendor": "siemens",
"version": "154"
},
{
"model": "simatic wincc runtime advanced update",
"scope": "ne",
"trust": 0.3,
"vendor": "siemens",
"version": "154"
},
{
"model": "simatic wincc update",
"scope": "ne",
"trust": 0.3,
"vendor": "siemens",
"version": "154"
},
{
"model": "simatic hmi ktp mobile panels update",
"scope": "ne",
"trust": 0.3,
"vendor": "siemens",
"version": "154"
},
{
"model": "simatic hmi comfort panels update",
"scope": "ne",
"trust": 0.3,
"vendor": "siemens",
"version": "154"
},
{
"model": "simatic hmi comfort outdoor panels update",
"scope": "ne",
"trust": 0.3,
"vendor": "siemens",
"version": "154"
}
],
"sources": [
{
"db": "BID",
"id": "105922"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-014525"
},
{
"db": "NVD",
"id": "CVE-2018-13812"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "15.0",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:simatic_hmi_comfort_panels:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "15.0",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:simatic_hmi_comfort_outdoor_panels:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "15.0",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp400f:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "15.0",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp700:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "15.0",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp700f:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "15.0",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp900:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "15.0",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp900f:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:a:siemens:simatic_wincc_runtime:*:*:*:*:professional:*:*:*",
"cpe_name": [],
"versionEndIncluding": "15.0",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:simatic_wincc_\\(tia_portal\\):*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "15.0",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:simatic_wincc_runtime:*:*:*:*:advanced:*:*:*",
"cpe_name": [],
"versionEndIncluding": "15.0",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:simatic_hmi_tp_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:simatic_hmi_tp:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:simatic_hmi_mp_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:simatic_hmi_mp:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:simatic_hmi_op_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:simatic_hmi_op:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2018-13812"
}
]
},
"credits": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/credits#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Hosni Tounsi from Carthage Red Team",
"sources": [
{
"db": "BID",
"id": "105922"
}
],
"trust": 0.3
},
"cve": "CVE-2018-13812",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"acInsufInfo": false,
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "NVD",
"availabilityImpact": "NONE",
"baseScore": 5.0,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 10.0,
"impactScore": 2.9,
"integrityImpact": "NONE",
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "MEDIUM",
"trust": 1.0,
"userInteractionRequired": false,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
"version": "2.0"
},
{
"acInsufInfo": null,
"accessComplexity": "Low",
"accessVector": "Network",
"authentication": "None",
"author": "NVD",
"availabilityImpact": "None",
"baseScore": 5.0,
"confidentialityImpact": "Partial",
"exploitabilityScore": null,
"id": "CVE-2018-13812",
"impactScore": null,
"integrityImpact": "None",
"obtainAllPrivilege": null,
"obtainOtherPrivilege": null,
"obtainUserPrivilege": null,
"severity": "Medium",
"trust": 0.8,
"userInteractionRequired": null,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "VULHUB",
"availabilityImpact": "NONE",
"baseScore": 5.0,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 10.0,
"id": "VHN-123909",
"impactScore": 2.9,
"integrityImpact": "NONE",
"severity": "MEDIUM",
"trust": 0.1,
"vectorString": "AV:N/AC:L/AU:N/C:P/I:N/A:N",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "NVD",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 3.9,
"impactScore": 3.6,
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.0"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "None",
"baseScore": 7.5,
"baseSeverity": "High",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "CVE-2018-13812",
"impactScore": null,
"integrityImpact": "None",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.0"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2018-13812",
"trust": 1.8,
"value": "HIGH"
},
{
"author": "CNNVD",
"id": "CNNVD-201811-482",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "VULHUB",
"id": "VHN-123909",
"trust": 0.1,
"value": "MEDIUM"
}
]
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-123909"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-014525"
},
{
"db": "NVD",
"id": "CVE-2018-13812"
},
{
"db": "CNNVD",
"id": "CNNVD-201811-482"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "A vulnerability has been identified in SIMATIC HMI Comfort Panels 4\" - 22\" (All versions \u003c V15 Update 4), SIMATIC HMI Comfort Outdoor Panels 7\" \u0026 15\" (All versions \u003c V15 Update 4), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V15 Update 4), SIMATIC WinCC Runtime Advanced (All versions \u003c V15 Update 4), SIMATIC WinCC Runtime Professional (All versions \u003c V15 Update 4), SIMATIC WinCC (TIA Portal) (All versions \u003c V15 Update 4), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). A directory traversal vulnerability could allow to download arbitrary files from the device. The security vulnerability could be exploited by an attacker with network access to the integrated web server. No user interaction and no authentication is required to exploit the vulnerability. The vulnerability impacts the confidentiality of the device. At the time of advisory publication no public exploitation of this security vulnerability was known. plural SIMATIC The product contains a path traversal vulnerability.Information may be obtained. Siemens SIMATIC Panels is prone to following security vulnerabilities:\n1. An open-redirection vulnerability\n2. A directory-traversal vulnerability\nRemote attackers may use a specially crafted request with directory-traversal sequences (\u0027../\u0027) to retrieve arbitrary files from the affected system in the context of the application or by constructing a crafted URI and enticing a user to follow it and when an unsuspecting victim follows the link, they may be redirected to an attacker-controlled site. are all HMI software used by Siemens in Germany to control and monitor machines and equipment",
"sources": [
{
"db": "NVD",
"id": "CVE-2018-13812"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-014525"
},
{
"db": "BID",
"id": "105922"
},
{
"db": "VULHUB",
"id": "VHN-123909"
}
],
"trust": 1.98
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2018-13812",
"trust": 2.8
},
{
"db": "BID",
"id": "105922",
"trust": 2.0
},
{
"db": "SIEMENS",
"id": "SSA-233109",
"trust": 1.7
},
{
"db": "ICS CERT",
"id": "ICSA-18-317-08",
"trust": 1.7
},
{
"db": "JVNDB",
"id": "JVNDB-2018-014525",
"trust": 0.8
},
{
"db": "CNNVD",
"id": "CNNVD-201811-482",
"trust": 0.7
},
{
"db": "VULHUB",
"id": "VHN-123909",
"trust": 0.1
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-123909"
},
{
"db": "BID",
"id": "105922"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-014525"
},
{
"db": "NVD",
"id": "CVE-2018-13812"
},
{
"db": "CNNVD",
"id": "CNNVD-201811-482"
}
]
},
"id": "VAR-201812-0343",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "VULHUB",
"id": "VHN-123909"
}
],
"trust": 0.7526804766666667
},
"last_update_date": "2023-12-18T13:13:37.113000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "SSA-233109",
"trust": 0.8,
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-233109.pdf"
},
{
"title": "Multiple Siemens Product path traversal vulnerability fixes",
"trust": 0.6,
"url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=86883"
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2018-014525"
},
{
"db": "CNNVD",
"id": "CNNVD-201811-482"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-22",
"trust": 1.9
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-123909"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-014525"
},
{
"db": "NVD",
"id": "CVE-2018-13812"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.7,
"url": "http://www.securityfocus.com/bid/105922"
},
{
"trust": 1.7,
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-233109.pdf"
},
{
"trust": 1.7,
"url": "https://ics-cert.us-cert.gov/advisories/icsa-18-317-08"
},
{
"trust": 0.8,
"url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2018-13812"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2018-13812"
},
{
"trust": 0.3,
"url": "http://subscriber.communications.siemens.com/"
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-123909"
},
{
"db": "BID",
"id": "105922"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-014525"
},
{
"db": "NVD",
"id": "CVE-2018-13812"
},
{
"db": "CNNVD",
"id": "CNNVD-201811-482"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "VULHUB",
"id": "VHN-123909"
},
{
"db": "BID",
"id": "105922"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-014525"
},
{
"db": "NVD",
"id": "CVE-2018-13812"
},
{
"db": "CNNVD",
"id": "CNNVD-201811-482"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2018-12-13T00:00:00",
"db": "VULHUB",
"id": "VHN-123909"
},
{
"date": "2018-11-14T00:00:00",
"db": "BID",
"id": "105922"
},
{
"date": "2019-03-26T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2018-014525"
},
{
"date": "2018-12-13T16:29:00.290000",
"db": "NVD",
"id": "CVE-2018-13812"
},
{
"date": "2018-11-15T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201811-482"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2019-10-09T00:00:00",
"db": "VULHUB",
"id": "VHN-123909"
},
{
"date": "2018-11-14T00:00:00",
"db": "BID",
"id": "105922"
},
{
"date": "2019-03-26T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2018-014525"
},
{
"date": "2019-10-09T23:34:33.327000",
"db": "NVD",
"id": "CVE-2018-13812"
},
{
"date": "2019-10-17T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201811-482"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201811-482"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "plural SIMATIC Path traversal vulnerability in products",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2018-014525"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "path traversal",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201811-482"
}
],
"trust": 0.6
}
}
VAR-201812-0344
Vulnerability from variot - Updated: 2023-12-18 13:13A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V15 Update 4), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions < V15 Update 4), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15 Update 4), SIMATIC WinCC Runtime Advanced (All versions < V15 Update 4), SIMATIC WinCC Runtime Professional (All versions < V15 Update 4), SIMATIC WinCC (TIA Portal) (All versions < V15 Update 4), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). The webserver of affected HMI devices may allow URL redirections to untrusted websites. An attacker must trick a valid user who is authenticated to the device into clicking on a malicious link to exploit the vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known. plural SIMATIC The product contains an open redirect vulnerability.Information may be obtained and information may be altered. Siemens SIMATIC HMI Comfort Panels are all Germany's Siemens (Siemens) company HMI software for control and monitoring of machines and equipment.
The webserver in several Siemens products has an open redirection vulnerability. Siemens SIMATIC Panels is prone to following security vulnerabilities: 1. An open-redirection vulnerability 2. A directory-traversal vulnerability Remote attackers may use a specially crafted request with directory-traversal sequences ('../') to retrieve arbitrary files from the affected system in the context of the application or by constructing a crafted URI and enticing a user to follow it and when an unsuspecting victim follows the link, they may be redirected to an attacker-controlled site
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-201812-0344",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "simatic hmi ktp mobile panels ktp400f",
"scope": "lte",
"trust": 1.0,
"vendor": "siemens",
"version": "15.0"
},
{
"model": "simatic hmi op",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "*"
},
{
"model": "simatic wincc runtime",
"scope": "lte",
"trust": 1.0,
"vendor": "siemens",
"version": "15.0"
},
{
"model": "simatic wincc \\",
"scope": "lte",
"trust": 1.0,
"vendor": "siemens",
"version": "15.0"
},
{
"model": "simatic hmi comfort panels",
"scope": "lte",
"trust": 1.0,
"vendor": "siemens",
"version": "15.0"
},
{
"model": "simatic hmi tp",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "*"
},
{
"model": "simatic hmi mp",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "*"
},
{
"model": "simatic hmi ktp mobile panels ktp900",
"scope": "lte",
"trust": 1.0,
"vendor": "siemens",
"version": "15.0"
},
{
"model": "simatic hmi comfort outdoor panels",
"scope": "lte",
"trust": 1.0,
"vendor": "siemens",
"version": "15.0"
},
{
"model": "simatic hmi ktp mobile panels ktp700",
"scope": "lte",
"trust": 1.0,
"vendor": "siemens",
"version": "15.0"
},
{
"model": "simatic hmi ktp mobile panels ktp900f",
"scope": "lte",
"trust": 1.0,
"vendor": "siemens",
"version": "15.0"
},
{
"model": "simatic hmi ktp mobile panels ktp700f",
"scope": "lte",
"trust": 1.0,
"vendor": "siemens",
"version": "15.0"
},
{
"model": "simatic hmi comfort outdoor panels",
"scope": null,
"trust": 0.8,
"vendor": "siemens",
"version": null
},
{
"model": "simatic hmi comfort panels",
"scope": null,
"trust": 0.8,
"vendor": "siemens",
"version": null
},
{
"model": "simatic hmi ktp mobile panels ktp400f",
"scope": null,
"trust": 0.8,
"vendor": "siemens",
"version": null
},
{
"model": "simatic hmi ktp mobile panels ktp700",
"scope": null,
"trust": 0.8,
"vendor": "siemens",
"version": null
},
{
"model": "simatic hmi ktp mobile panels ktp700f",
"scope": null,
"trust": 0.8,
"vendor": "siemens",
"version": null
},
{
"model": "simatic hmi ktp mobile panels ktp900",
"scope": null,
"trust": 0.8,
"vendor": "siemens",
"version": null
},
{
"model": "simatic hmi ktp mobile panels ktp900f",
"scope": null,
"trust": 0.8,
"vendor": "siemens",
"version": null
},
{
"model": "simatic wincc",
"scope": null,
"trust": 0.8,
"vendor": "siemens",
"version": null
},
{
"model": "simatic wincc runtime advanced",
"scope": null,
"trust": 0.8,
"vendor": "siemens",
"version": null
},
{
"model": "simatic wincc runtime professional",
"scope": null,
"trust": 0.8,
"vendor": "siemens",
"version": null
},
{
"model": "simatic hmi classic devices",
"scope": null,
"trust": 0.6,
"vendor": "siemens",
"version": null
},
{
"model": "simatic hmi comfort outdoor panels 7\" \u0026 15\" update",
"scope": "lt",
"trust": 0.6,
"vendor": "siemens",
"version": "154"
},
{
"model": "simatic hmi comfort panels 4\"-22\" update",
"scope": "lt",
"trust": 0.6,
"vendor": "siemens",
"version": "154"
},
{
"model": "simatic hmi ktp mobile panels update",
"scope": "lt",
"trust": 0.6,
"vendor": "siemens",
"version": "154"
},
{
"model": "simatic wincc update",
"scope": "lt",
"trust": 0.6,
"vendor": "siemens",
"version": "154"
},
{
"model": "simatic wincc runtime advanced update",
"scope": "lt",
"trust": 0.6,
"vendor": "siemens",
"version": "154"
},
{
"model": "simatic wincc runtime professional update",
"scope": "lt",
"trust": 0.6,
"vendor": "siemens",
"version": "154"
},
{
"model": null,
"scope": "eq",
"trust": 0.4,
"vendor": "simatic wincc runtime",
"version": "*"
},
{
"model": "simatic wincc runtime professional",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "15"
},
{
"model": "simatic wincc runtime professional sp1",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "14"
},
{
"model": "simatic wincc runtime professional",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "14"
},
{
"model": "simatic wincc runtime professional sp2",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "13"
},
{
"model": "simatic wincc runtime professional sp1 upd2",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "13"
},
{
"model": "simatic wincc runtime professional sp update",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "1319"
},
{
"model": "simatic wincc runtime professional",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "13"
},
{
"model": "simatic wincc runtime advanced",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "15"
},
{
"model": "simatic wincc runtime advanced sp1 upd2",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "13"
},
{
"model": "simatic wincc runtime advanced",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "13"
},
{
"model": "simatic wincc runtime advanced sp1 upd5",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "12"
},
{
"model": "simatic wincc runtime advanced",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "12"
},
{
"model": "simatic wincc runtime advanced",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "0"
},
{
"model": "simatic wincc update",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "v135"
},
{
"model": "simatic wincc sp1",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "v12"
},
{
"model": "simatic wincc",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "v120"
},
{
"model": "simatic wincc",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "v110"
},
{
"model": "simatic wincc",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "v15"
},
{
"model": "simatic wincc update",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "v136"
},
{
"model": "simatic wincc sp1",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "v13"
},
{
"model": "simatic wincc",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "v13"
},
{
"model": "simatic wincc",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "v10"
},
{
"model": "simatic hmi ktp mobile panels",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "0"
},
{
"model": "simatic hmi comfort panels",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "4"
},
{
"model": "simatic hmi comfort panels",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "22"
},
{
"model": "simatic hmi comfort panels",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "15"
},
{
"model": "simatic hmi comfort panels sp1 upd2",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "13"
},
{
"model": "simatic hmi comfort panels",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "13"
},
{
"model": "simatic hmi comfort panels sp1 upd5",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "12"
},
{
"model": "simatic hmi comfort panels",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "12"
},
{
"model": "simatic hmi comfort panels",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "0"
},
{
"model": "simatic hmi comfort outdoor panels",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "0"
},
{
"model": "simatic hmi classic devices",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "0"
},
{
"model": "simatic wincc runtime professional update",
"scope": "ne",
"trust": 0.3,
"vendor": "siemens",
"version": "154"
},
{
"model": "simatic wincc runtime advanced update",
"scope": "ne",
"trust": 0.3,
"vendor": "siemens",
"version": "154"
},
{
"model": "simatic wincc update",
"scope": "ne",
"trust": 0.3,
"vendor": "siemens",
"version": "154"
},
{
"model": "simatic hmi ktp mobile panels update",
"scope": "ne",
"trust": 0.3,
"vendor": "siemens",
"version": "154"
},
{
"model": "simatic hmi comfort panels update",
"scope": "ne",
"trust": 0.3,
"vendor": "siemens",
"version": "154"
},
{
"model": "simatic hmi comfort outdoor panels update",
"scope": "ne",
"trust": 0.3,
"vendor": "siemens",
"version": "154"
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "simatic hmi comfort panels",
"version": "*"
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "simatic hmi mp",
"version": "*"
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "simatic hmi op",
"version": "*"
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "simatic hmi comfort outdoor panels",
"version": "*"
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "simatic hmi ktp mobile panels ktp400f",
"version": "*"
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "simatic hmi ktp mobile panels ktp700",
"version": "*"
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "simatic hmi ktp mobile panels ktp700f",
"version": "*"
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "simatic hmi ktp mobile panels ktp900",
"version": "*"
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "simatic hmi ktp mobile panels ktp900f",
"version": "*"
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "simatic wincc tia portal",
"version": "*"
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "simatic hmi tp",
"version": "*"
}
],
"sources": [
{
"db": "IVD",
"id": "e30112c1-39ab-11e9-9eae-000c29342cb1"
},
{
"db": "CNVD",
"id": "CNVD-2018-24247"
},
{
"db": "BID",
"id": "105922"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-014526"
},
{
"db": "NVD",
"id": "CVE-2018-13813"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "15.0",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:simatic_hmi_comfort_panels:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "15.0",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:simatic_hmi_comfort_outdoor_panels:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "15.0",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp400f:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "15.0",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp700:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "15.0",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp700f:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "15.0",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp900:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "15.0",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp900f:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:a:siemens:simatic_wincc_runtime:*:*:*:*:advanced:*:*:*",
"cpe_name": [],
"versionEndIncluding": "15.0",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:simatic_wincc_runtime:*:*:*:*:professional:*:*:*",
"cpe_name": [],
"versionEndIncluding": "15.0",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:simatic_wincc_\\(tia_portal\\):*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "15.0",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:simatic_hmi_tp_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:simatic_hmi_tp:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:simatic_hmi_mp_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:simatic_hmi_mp:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:simatic_hmi_op_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:simatic_hmi_op:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2018-13813"
}
]
},
"credits": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/credits#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Hosni Tounsi from Carthage Red Team",
"sources": [
{
"db": "BID",
"id": "105922"
}
],
"trust": 0.3
},
"cve": "CVE-2018-13813",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"acInsufInfo": false,
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "NVD",
"availabilityImpact": "NONE",
"baseScore": 5.8,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 8.6,
"impactScore": 4.9,
"integrityImpact": "PARTIAL",
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "MEDIUM",
"trust": 1.0,
"userInteractionRequired": true,
"vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:N",
"version": "2.0"
},
{
"acInsufInfo": null,
"accessComplexity": "Medium",
"accessVector": "Network",
"authentication": "None",
"author": "NVD",
"availabilityImpact": "None",
"baseScore": 5.8,
"confidentialityImpact": "Partial",
"exploitabilityScore": null,
"id": "CVE-2018-13813",
"impactScore": null,
"integrityImpact": "Partial",
"obtainAllPrivilege": null,
"obtainOtherPrivilege": null,
"obtainUserPrivilege": null,
"severity": "Medium",
"trust": 0.8,
"userInteractionRequired": null,
"vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:N",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "NONE",
"baseScore": 7.8,
"confidentialityImpact": "NONE",
"exploitabilityScore": 10.0,
"id": "CNVD-2018-24247",
"impactScore": 6.9,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:N/I:C/A:N",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "IVD",
"availabilityImpact": "NONE",
"baseScore": 7.8,
"confidentialityImpact": "NONE",
"exploitabilityScore": 10.0,
"id": "e30112c1-39ab-11e9-9eae-000c29342cb1",
"impactScore": 6.9,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.2,
"vectorString": "AV:N/AC:L/Au:N/C:N/I:C/A:N",
"version": "2.9 [IVD]"
},
{
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "VULHUB",
"availabilityImpact": "NONE",
"baseScore": 5.8,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 8.6,
"id": "VHN-123910",
"impactScore": 4.9,
"integrityImpact": "PARTIAL",
"severity": "MEDIUM",
"trust": 0.1,
"vectorString": "AV:N/AC:M/AU:N/C:P/I:P/A:N",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "NVD",
"availabilityImpact": "NONE",
"baseScore": 8.1,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 2.8,
"impactScore": 5.2,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:N",
"version": "3.0"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "None",
"baseScore": 8.1,
"baseSeverity": "High",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "CVE-2018-13813",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "Required",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:N",
"version": "3.0"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2018-13813",
"trust": 1.8,
"value": "HIGH"
},
{
"author": "CNVD",
"id": "CNVD-2018-24247",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "CNNVD",
"id": "CNNVD-201811-483",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "IVD",
"id": "e30112c1-39ab-11e9-9eae-000c29342cb1",
"trust": 0.2,
"value": "HIGH"
},
{
"author": "VULHUB",
"id": "VHN-123910",
"trust": 0.1,
"value": "MEDIUM"
}
]
}
],
"sources": [
{
"db": "IVD",
"id": "e30112c1-39ab-11e9-9eae-000c29342cb1"
},
{
"db": "CNVD",
"id": "CNVD-2018-24247"
},
{
"db": "VULHUB",
"id": "VHN-123910"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-014526"
},
{
"db": "NVD",
"id": "CVE-2018-13813"
},
{
"db": "CNNVD",
"id": "CNNVD-201811-483"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "A vulnerability has been identified in SIMATIC HMI Comfort Panels 4\" - 22\" (All versions \u003c V15 Update 4), SIMATIC HMI Comfort Outdoor Panels 7\" \u0026 15\" (All versions \u003c V15 Update 4), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V15 Update 4), SIMATIC WinCC Runtime Advanced (All versions \u003c V15 Update 4), SIMATIC WinCC Runtime Professional (All versions \u003c V15 Update 4), SIMATIC WinCC (TIA Portal) (All versions \u003c V15 Update 4), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). The webserver of affected HMI devices may allow URL redirections to untrusted websites. An attacker must trick a valid user who is authenticated to the device into clicking on a malicious link to exploit the vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known. plural SIMATIC The product contains an open redirect vulnerability.Information may be obtained and information may be altered. Siemens SIMATIC HMI Comfort Panels are all Germany\u0027s Siemens (Siemens) company HMI software for control and monitoring of machines and equipment. \n\nThe webserver in several Siemens products has an open redirection vulnerability. Siemens SIMATIC Panels is prone to following security vulnerabilities:\n1. An open-redirection vulnerability\n2. A directory-traversal vulnerability\nRemote attackers may use a specially crafted request with directory-traversal sequences (\u0027../\u0027) to retrieve arbitrary files from the affected system in the context of the application or by constructing a crafted URI and enticing a user to follow it and when an unsuspecting victim follows the link, they may be redirected to an attacker-controlled site",
"sources": [
{
"db": "NVD",
"id": "CVE-2018-13813"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-014526"
},
{
"db": "CNVD",
"id": "CNVD-2018-24247"
},
{
"db": "BID",
"id": "105922"
},
{
"db": "IVD",
"id": "e30112c1-39ab-11e9-9eae-000c29342cb1"
},
{
"db": "VULHUB",
"id": "VHN-123910"
}
],
"trust": 2.7
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2018-13813",
"trust": 3.6
},
{
"db": "SIEMENS",
"id": "SSA-233109",
"trust": 2.3
},
{
"db": "ICS CERT",
"id": "ICSA-18-317-08",
"trust": 2.3
},
{
"db": "BID",
"id": "105922",
"trust": 2.0
},
{
"db": "CNNVD",
"id": "CNNVD-201811-483",
"trust": 0.9
},
{
"db": "CNVD",
"id": "CNVD-2018-24247",
"trust": 0.8
},
{
"db": "JVNDB",
"id": "JVNDB-2018-014526",
"trust": 0.8
},
{
"db": "IVD",
"id": "E30112C1-39AB-11E9-9EAE-000C29342CB1",
"trust": 0.2
},
{
"db": "VULHUB",
"id": "VHN-123910",
"trust": 0.1
}
],
"sources": [
{
"db": "IVD",
"id": "e30112c1-39ab-11e9-9eae-000c29342cb1"
},
{
"db": "CNVD",
"id": "CNVD-2018-24247"
},
{
"db": "VULHUB",
"id": "VHN-123910"
},
{
"db": "BID",
"id": "105922"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-014526"
},
{
"db": "NVD",
"id": "CVE-2018-13813"
},
{
"db": "CNNVD",
"id": "CNNVD-201811-483"
}
]
},
"id": "VAR-201812-0344",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "IVD",
"id": "e30112c1-39ab-11e9-9eae-000c29342cb1"
},
{
"db": "CNVD",
"id": "CNVD-2018-24247"
},
{
"db": "VULHUB",
"id": "VHN-123910"
}
],
"trust": 1.5670710088235296
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"ICS"
],
"sub_category": null,
"trust": 0.8
}
],
"sources": [
{
"db": "IVD",
"id": "e30112c1-39ab-11e9-9eae-000c29342cb1"
},
{
"db": "CNVD",
"id": "CNVD-2018-24247"
}
]
},
"last_update_date": "2023-12-18T13:13:37.075000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "SSA-233109",
"trust": 0.8,
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-233109.pdf"
},
{
"title": "Patch for Multiple Siemens products open redirection vulnerability",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchinfo/show/176377"
},
{
"title": "Multiple Siemens Product security vulnerabilities",
"trust": 0.6,
"url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=86884"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2018-24247"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-014526"
},
{
"db": "CNNVD",
"id": "CNNVD-201811-483"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-601",
"trust": 1.9
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-123910"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-014526"
},
{
"db": "NVD",
"id": "CVE-2018-13813"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.3,
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-233109.pdf"
},
{
"trust": 2.3,
"url": "https://ics-cert.us-cert.gov/advisories/icsa-18-317-08"
},
{
"trust": 1.7,
"url": "http://www.securityfocus.com/bid/105922"
},
{
"trust": 0.8,
"url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2018-13813"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2018-13813"
},
{
"trust": 0.3,
"url": "http://subscriber.communications.siemens.com/"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2018-24247"
},
{
"db": "VULHUB",
"id": "VHN-123910"
},
{
"db": "BID",
"id": "105922"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-014526"
},
{
"db": "NVD",
"id": "CVE-2018-13813"
},
{
"db": "CNNVD",
"id": "CNNVD-201811-483"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "IVD",
"id": "e30112c1-39ab-11e9-9eae-000c29342cb1"
},
{
"db": "CNVD",
"id": "CNVD-2018-24247"
},
{
"db": "VULHUB",
"id": "VHN-123910"
},
{
"db": "BID",
"id": "105922"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-014526"
},
{
"db": "NVD",
"id": "CVE-2018-13813"
},
{
"db": "CNNVD",
"id": "CNNVD-201811-483"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2018-11-29T00:00:00",
"db": "IVD",
"id": "e30112c1-39ab-11e9-9eae-000c29342cb1"
},
{
"date": "2018-11-29T00:00:00",
"db": "CNVD",
"id": "CNVD-2018-24247"
},
{
"date": "2018-12-13T00:00:00",
"db": "VULHUB",
"id": "VHN-123910"
},
{
"date": "2018-11-14T00:00:00",
"db": "BID",
"id": "105922"
},
{
"date": "2019-03-26T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2018-014526"
},
{
"date": "2018-12-13T16:29:00.320000",
"db": "NVD",
"id": "CVE-2018-13813"
},
{
"date": "2018-11-15T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201811-483"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2019-08-22T00:00:00",
"db": "CNVD",
"id": "CNVD-2018-24247"
},
{
"date": "2019-10-09T00:00:00",
"db": "VULHUB",
"id": "VHN-123910"
},
{
"date": "2018-11-14T00:00:00",
"db": "BID",
"id": "105922"
},
{
"date": "2019-03-26T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2018-014526"
},
{
"date": "2019-10-09T23:34:33.607000",
"db": "NVD",
"id": "CVE-2018-13813"
},
{
"date": "2019-10-17T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201811-483"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201811-483"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "plural SIMATIC Open redirect vulnerability in products",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2018-014526"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Input validation error",
"sources": [
{
"db": "IVD",
"id": "e30112c1-39ab-11e9-9eae-000c29342cb1"
},
{
"db": "BID",
"id": "105922"
},
{
"db": "CNNVD",
"id": "CNNVD-201811-483"
}
],
"trust": 1.1
}
}
VAR-202108-2032
Vulnerability from variot - Updated: 2023-12-18 13:12In OPC Foundation Local Discovery Server (LDS) before 1.04.402.463, remote attackers can cause a denial of service (DoS) by sending carefully crafted messages that lead to Access of a Memory Location After the End of a Buffer. The Local Discovery Server provides the necessary infrastructure to publicly expose the OPC UA servers available on a given computer
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202108-2032",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "simatic process historian opc ua server",
"scope": "lt",
"trust": 1.0,
"vendor": "siemens",
"version": "2022"
},
{
"model": "local discover server",
"scope": "lt",
"trust": 1.0,
"vendor": "opcfoundation",
"version": "1.04.402.463"
},
{
"model": "simatic wincc unified scada runtime",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "simatic net pc",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "14"
},
{
"model": "simatic net pc",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "16"
},
{
"model": "simatic net pc",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "15"
},
{
"model": "simatic net pc",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "17"
},
{
"model": "simatic wincc runtime",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "telecontrol server basic",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "3.0"
},
{
"model": "simatic wincc",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "simatic process historian opc ua server",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "2022"
},
{
"model": "local discovery server",
"scope": "eq",
"trust": 0.8,
"vendor": "opc",
"version": null
},
{
"model": "local discovery server",
"scope": "eq",
"trust": 0.8,
"vendor": "opc",
"version": "1.04.402.463"
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2021-010007"
},
{
"db": "NVD",
"id": "CVE-2021-40142"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:a:opcfoundation:local_discover_server:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "1.04.402.463",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:simatic_process_historian_opc_ua_server_firmware:2022:-:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:o:siemens:simatic_process_historian_opc_ua_server_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "2022",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:simatic_process_historian_opc_ua_server:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:a:siemens:simatic_wincc_runtime:-:*:*:*:professional:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:simatic_wincc:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:simatic_net_pc:16:-:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:simatic_net_pc:15:-:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:simatic_net_pc:14:-:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:telecontrol_server_basic:3.0:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:simatic_net_pc:17:-:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:simatic_wincc_unified_scada_runtime:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2021-40142"
}
]
},
"credits": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/credits#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Siemens reported this vulnerability to CISA.",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202108-2640"
}
],
"trust": 0.6
},
"cve": "CVE-2021-40142",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"acInsufInfo": false,
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "NVD",
"availabilityImpact": "PARTIAL",
"baseScore": 5.0,
"confidentialityImpact": "NONE",
"exploitabilityScore": 10.0,
"impactScore": 2.9,
"integrityImpact": "NONE",
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "MEDIUM",
"trust": 1.0,
"userInteractionRequired": false,
"vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
"version": "2.0"
},
{
"acInsufInfo": null,
"accessComplexity": "Low",
"accessVector": "Network",
"authentication": "None",
"author": "NVD",
"availabilityImpact": "Partial",
"baseScore": 5.0,
"confidentialityImpact": "None",
"exploitabilityScore": null,
"id": "CVE-2021-40142",
"impactScore": null,
"integrityImpact": "None",
"obtainAllPrivilege": null,
"obtainOtherPrivilege": null,
"obtainUserPrivilege": null,
"severity": "Medium",
"trust": 0.9,
"userInteractionRequired": null,
"vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "VULHUB",
"availabilityImpact": "PARTIAL",
"baseScore": 5.0,
"confidentialityImpact": "NONE",
"exploitabilityScore": 10.0,
"id": "VHN-397219",
"impactScore": 2.9,
"integrityImpact": "NONE",
"severity": "MEDIUM",
"trust": 0.1,
"vectorString": "AV:N/AC:L/AU:N/C:N/I:N/A:P",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "NVD",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"exploitabilityScore": 3.9,
"impactScore": 3.6,
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 2.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "OTHER",
"availabilityImpact": "High",
"baseScore": 7.5,
"baseSeverity": "High",
"confidentialityImpact": "None",
"exploitabilityScore": null,
"id": "JVNDB-2021-010007",
"impactScore": null,
"integrityImpact": "None",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2021-40142",
"trust": 1.8,
"value": "HIGH"
},
{
"author": "cve@mitre.org",
"id": "CVE-2021-40142",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "CNNVD",
"id": "CNNVD-202108-2640",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "VULHUB",
"id": "VHN-397219",
"trust": 0.1,
"value": "MEDIUM"
},
{
"author": "VULMON",
"id": "CVE-2021-40142",
"trust": 0.1,
"value": "MEDIUM"
}
]
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-397219"
},
{
"db": "VULMON",
"id": "CVE-2021-40142"
},
{
"db": "JVNDB",
"id": "JVNDB-2021-010007"
},
{
"db": "NVD",
"id": "CVE-2021-40142"
},
{
"db": "NVD",
"id": "CVE-2021-40142"
},
{
"db": "CNNVD",
"id": "CNNVD-202108-2640"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "In OPC Foundation Local Discovery Server (LDS) before 1.04.402.463, remote attackers can cause a denial of service (DoS) by sending carefully crafted messages that lead to Access of a Memory Location After the End of a Buffer. The Local Discovery Server provides the necessary infrastructure to publicly expose the OPC UA servers available on a given computer",
"sources": [
{
"db": "NVD",
"id": "CVE-2021-40142"
},
{
"db": "JVNDB",
"id": "JVNDB-2021-010007"
},
{
"db": "VULHUB",
"id": "VHN-397219"
},
{
"db": "VULMON",
"id": "CVE-2021-40142"
}
],
"trust": 1.8
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2021-40142",
"trust": 3.4
},
{
"db": "SIEMENS",
"id": "SSA-321292",
"trust": 1.8
},
{
"db": "JVNDB",
"id": "JVNDB-2021-010007",
"trust": 0.8
},
{
"db": "CNNVD",
"id": "CNNVD-202108-2640",
"trust": 0.7
},
{
"db": "ICS CERT",
"id": "ICSA-22-132-12",
"trust": 0.7
},
{
"db": "CS-HELP",
"id": "SB2022051720",
"trust": 0.6
},
{
"db": "VULHUB",
"id": "VHN-397219",
"trust": 0.1
},
{
"db": "VULMON",
"id": "CVE-2021-40142",
"trust": 0.1
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-397219"
},
{
"db": "VULMON",
"id": "CVE-2021-40142"
},
{
"db": "JVNDB",
"id": "JVNDB-2021-010007"
},
{
"db": "NVD",
"id": "CVE-2021-40142"
},
{
"db": "CNNVD",
"id": "CNNVD-202108-2640"
}
]
},
"id": "VAR-202108-2032",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "VULHUB",
"id": "VHN-397219"
}
],
"trust": 0.613684795
},
"last_update_date": "2023-12-18T13:12:25.198000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Security\u00a0Update\u00a0for\u00a0Local\u00a0Discovery\u00a0Server\u00a0(LDS) OPC\u00a0Foundation\u00a0Security\u00a0Bulletin",
"trust": 0.8,
"url": "https://files.opcfoundation.org/securitybulletins/opc%20foundation%20security%20bulletin%20cve-2021-40142.pdf"
},
{
"title": "Local Discovery Server Buffer error vulnerability fix",
"trust": 0.6,
"url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=161299"
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2021-010007"
},
{
"db": "CNNVD",
"id": "CNNVD-202108-2640"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-119",
"trust": 1.1
},
{
"problemtype": "Buffer error (CWE-119) [NVD evaluation ]",
"trust": 0.8
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-397219"
},
{
"db": "JVNDB",
"id": "JVNDB-2021-010007"
},
{
"db": "NVD",
"id": "CVE-2021-40142"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.8,
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-321292.pdf"
},
{
"trust": 1.8,
"url": "https://files.opcfoundation.org/securitybulletins/opc%20foundation%20security%20bulletin%20cve-2021-40142.pdf"
},
{
"trust": 1.8,
"url": "https://opcfoundation.org/security-bulletins/"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2021-40142"
},
{
"trust": 0.6,
"url": "https://vigilance.fr/vulnerability/siemens-simatic-denial-of-service-via-opc-foundation-local-discovery-server-38294"
},
{
"trust": 0.6,
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-22-132-12"
},
{
"trust": 0.6,
"url": "https://www.cybersecurity-help.cz/vdb/sb2022051720"
},
{
"trust": 0.1,
"url": "https://cwe.mitre.org/data/definitions/119.html"
},
{
"trust": 0.1,
"url": "https://github.com/live-hack-cve/cve-2021-40142"
},
{
"trust": 0.1,
"url": "https://nvd.nist.gov"
},
{
"trust": 0.1,
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-132-12"
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-397219"
},
{
"db": "VULMON",
"id": "CVE-2021-40142"
},
{
"db": "JVNDB",
"id": "JVNDB-2021-010007"
},
{
"db": "NVD",
"id": "CVE-2021-40142"
},
{
"db": "CNNVD",
"id": "CNNVD-202108-2640"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "VULHUB",
"id": "VHN-397219"
},
{
"db": "VULMON",
"id": "CVE-2021-40142"
},
{
"db": "JVNDB",
"id": "JVNDB-2021-010007"
},
{
"db": "NVD",
"id": "CVE-2021-40142"
},
{
"db": "CNNVD",
"id": "CNNVD-202108-2640"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2021-08-27T00:00:00",
"db": "VULHUB",
"id": "VHN-397219"
},
{
"date": "2021-08-27T00:00:00",
"db": "VULMON",
"id": "CVE-2021-40142"
},
{
"date": "2022-06-13T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2021-010007"
},
{
"date": "2021-08-27T07:15:08.630000",
"db": "NVD",
"id": "CVE-2021-40142"
},
{
"date": "2021-08-27T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202108-2640"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2022-09-03T00:00:00",
"db": "VULHUB",
"id": "VHN-397219"
},
{
"date": "2022-09-03T00:00:00",
"db": "VULMON",
"id": "CVE-2021-40142"
},
{
"date": "2022-06-13T08:39:00",
"db": "JVNDB",
"id": "JVNDB-2021-010007"
},
{
"date": "2022-09-03T03:54:54.180000",
"db": "NVD",
"id": "CVE-2021-40142"
},
{
"date": "2022-05-18T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202108-2640"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202108-2640"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "OPC\u00a0Foundation\u00a0Local\u00a0Discovery\u00a0Server\u00a0 Buffer error vulnerability in",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2021-010007"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "buffer error",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202108-2640"
}
],
"trust": 0.6
}
}
VAR-201306-0316
Vulnerability from variot - Updated: 2023-12-18 13:09The Web Navigator in Siemens WinCC before 7.2 Update 1, as used in SIMATIC PCS7 8.0 SP1 and earlier and other products, exhibits different behavior for NetBIOS user names depending on whether the user account exists, which allows remote authenticated users to enumerate account names via crafted URL parameters. Siemens SIMATIC WinCC is a monitoring control and data acquisition SCADA and human machine interface HMI system. Siemens SIMATIC PCS is a process control system. Siemens SIMATIC WinCC And PCS 7 are prone to a username-enumeration weakness because of a design error in the application when verifying user-supplied input. Attackers may exploit this weakness to discern valid usernames. This may aid brute-force password cracking or other attacks. There is a vulnerability in the Web Navigator in Siemens WinCC 7.2 Update 1 and earlier versions used in SIMATIC PCS7 8.0 SP1 and earlier versions and other products
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-201306-0316",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "wincc",
"scope": "eq",
"trust": 1.6,
"vendor": "siemens",
"version": "7.0"
},
{
"model": "wincc",
"scope": "eq",
"trust": 1.6,
"vendor": "siemens",
"version": "7.1"
},
{
"model": "simatic pcs7",
"scope": "eq",
"trust": 1.6,
"vendor": "siemens",
"version": "8.0"
},
{
"model": "simatic pcs7",
"scope": "lte",
"trust": 1.0,
"vendor": "siemens",
"version": "8.0"
},
{
"model": "wincc",
"scope": "lte",
"trust": 1.0,
"vendor": "siemens",
"version": "7.2"
},
{
"model": null,
"scope": "eq",
"trust": 0.8,
"vendor": "wincc",
"version": "7.0"
},
{
"model": "simatic pcs 7",
"scope": "lte",
"trust": 0.8,
"vendor": "siemens",
"version": "8.0 sp1"
},
{
"model": "simatic wincc",
"scope": "lt",
"trust": 0.8,
"vendor": "siemens",
"version": "7.2 update 1"
},
{
"model": "simatic wincc",
"scope": "eq",
"trust": 0.6,
"vendor": "siemens",
"version": "7.x"
},
{
"model": "simatic pcs",
"scope": "eq",
"trust": 0.6,
"vendor": "siemens",
"version": "78.x"
},
{
"model": "wincc",
"scope": "eq",
"trust": 0.6,
"vendor": "siemens",
"version": "7.2"
},
{
"model": null,
"scope": "eq",
"trust": 0.4,
"vendor": "wincc",
"version": "7.1"
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "simatic pcs7",
"version": "8.0"
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "simatic pcs7",
"version": "*"
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "wincc",
"version": "*"
}
],
"sources": [
{
"db": "IVD",
"id": "e694e1ea-2352-11e6-abef-000c29c66e3d"
},
{
"db": "CNVD",
"id": "CNVD-2013-07608"
},
{
"db": "JVNDB",
"id": "JVNDB-2013-002984"
},
{
"db": "NVD",
"id": "CVE-2013-3959"
},
{
"db": "CNNVD",
"id": "CNNVD-201306-249"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:a:siemens:wincc:7.0:sp2:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:wincc:7.0:sp1:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:wincc:7.0:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:wincc:7.1:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:wincc:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "7.2",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:simatic_pcs7:8.0:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:wincc:7.0:sp3:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:wincc:7.1:sp1:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:simatic_pcs7:*:sp1:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "8.0",
"vulnerable": true
}
],
"operator": "OR"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2013-3959"
}
]
},
"credits": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/credits#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Alexander Tlyapov from Positive Technologies",
"sources": [
{
"db": "BID",
"id": "60559"
}
],
"trust": 0.3
},
"cve": "CVE-2013-3959",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"acInsufInfo": false,
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"author": "NVD",
"availabilityImpact": "NONE",
"baseScore": 4.0,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 8.0,
"impactScore": 2.9,
"integrityImpact": "NONE",
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "MEDIUM",
"trust": 1.0,
"userInteractionRequired": false,
"vectorString": "AV:N/AC:L/Au:S/C:P/I:N/A:N",
"version": "2.0"
},
{
"acInsufInfo": null,
"accessComplexity": "Low",
"accessVector": "Network",
"authentication": "Single",
"author": "NVD",
"availabilityImpact": "None",
"baseScore": 4.0,
"confidentialityImpact": "Partial",
"exploitabilityScore": null,
"id": "CVE-2013-3959",
"impactScore": null,
"integrityImpact": "None",
"obtainAllPrivilege": null,
"obtainOtherPrivilege": null,
"obtainUserPrivilege": null,
"severity": "Medium",
"trust": 0.8,
"userInteractionRequired": null,
"vectorString": "AV:N/AC:L/Au:S/C:P/I:N/A:N",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"author": "CNVD",
"availabilityImpact": "NONE",
"baseScore": 4.0,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 8.0,
"id": "CNVD-2013-07608",
"impactScore": 2.9,
"integrityImpact": "NONE",
"severity": "MEDIUM",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:S/C:P/I:N/A:N",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"author": "IVD",
"availabilityImpact": "NONE",
"baseScore": 4.0,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 8.0,
"id": "e694e1ea-2352-11e6-abef-000c29c66e3d",
"impactScore": 2.9,
"integrityImpact": "NONE",
"severity": "MEDIUM",
"trust": 0.2,
"vectorString": "AV:N/AC:L/Au:S/C:P/I:N/A:N",
"version": "2.9 [IVD]"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"author": "VULHUB",
"availabilityImpact": "NONE",
"baseScore": 4.0,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 8.0,
"id": "VHN-63961",
"impactScore": 2.9,
"integrityImpact": "NONE",
"severity": "MEDIUM",
"trust": 0.1,
"vectorString": "AV:N/AC:L/AU:S/C:P/I:N/A:N",
"version": "2.0"
}
],
"cvssV3": [],
"severity": [
{
"author": "NVD",
"id": "CVE-2013-3959",
"trust": 1.8,
"value": "MEDIUM"
},
{
"author": "CNVD",
"id": "CNVD-2013-07608",
"trust": 0.6,
"value": "MEDIUM"
},
{
"author": "CNNVD",
"id": "CNNVD-201306-249",
"trust": 0.6,
"value": "MEDIUM"
},
{
"author": "IVD",
"id": "e694e1ea-2352-11e6-abef-000c29c66e3d",
"trust": 0.2,
"value": "MEDIUM"
},
{
"author": "VULHUB",
"id": "VHN-63961",
"trust": 0.1,
"value": "MEDIUM"
}
]
}
],
"sources": [
{
"db": "IVD",
"id": "e694e1ea-2352-11e6-abef-000c29c66e3d"
},
{
"db": "CNVD",
"id": "CNVD-2013-07608"
},
{
"db": "VULHUB",
"id": "VHN-63961"
},
{
"db": "JVNDB",
"id": "JVNDB-2013-002984"
},
{
"db": "NVD",
"id": "CVE-2013-3959"
},
{
"db": "CNNVD",
"id": "CNNVD-201306-249"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "The Web Navigator in Siemens WinCC before 7.2 Update 1, as used in SIMATIC PCS7 8.0 SP1 and earlier and other products, exhibits different behavior for NetBIOS user names depending on whether the user account exists, which allows remote authenticated users to enumerate account names via crafted URL parameters. Siemens SIMATIC WinCC is a monitoring control and data acquisition SCADA and human machine interface HMI system. Siemens SIMATIC PCS is a process control system. Siemens SIMATIC WinCC And PCS 7 are prone to a username-enumeration weakness because of a design error in the application when verifying user-supplied input. \nAttackers may exploit this weakness to discern valid usernames. This may aid brute-force password cracking or other attacks. There is a vulnerability in the Web Navigator in Siemens WinCC 7.2 Update 1 and earlier versions used in SIMATIC PCS7 8.0 SP1 and earlier versions and other products",
"sources": [
{
"db": "NVD",
"id": "CVE-2013-3959"
},
{
"db": "JVNDB",
"id": "JVNDB-2013-002984"
},
{
"db": "CNVD",
"id": "CNVD-2013-07608"
},
{
"db": "BID",
"id": "60559"
},
{
"db": "IVD",
"id": "e694e1ea-2352-11e6-abef-000c29c66e3d"
},
{
"db": "VULHUB",
"id": "VHN-63961"
}
],
"trust": 2.7
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2013-3959",
"trust": 3.6
},
{
"db": "SIEMENS",
"id": "SSA-345843",
"trust": 2.0
},
{
"db": "SECUNIA",
"id": "53805",
"trust": 1.2
},
{
"db": "ICS CERT",
"id": "ICSA-13-169-02",
"trust": 1.1
},
{
"db": "BID",
"id": "60559",
"trust": 1.0
},
{
"db": "CNNVD",
"id": "CNNVD-201306-249",
"trust": 0.9
},
{
"db": "CNVD",
"id": "CNVD-2013-07608",
"trust": 0.8
},
{
"db": "JVNDB",
"id": "JVNDB-2013-002984",
"trust": 0.8
},
{
"db": "IVD",
"id": "E694E1EA-2352-11E6-ABEF-000C29C66E3D",
"trust": 0.2
},
{
"db": "VULHUB",
"id": "VHN-63961",
"trust": 0.1
}
],
"sources": [
{
"db": "IVD",
"id": "e694e1ea-2352-11e6-abef-000c29c66e3d"
},
{
"db": "CNVD",
"id": "CNVD-2013-07608"
},
{
"db": "VULHUB",
"id": "VHN-63961"
},
{
"db": "BID",
"id": "60559"
},
{
"db": "JVNDB",
"id": "JVNDB-2013-002984"
},
{
"db": "NVD",
"id": "CVE-2013-3959"
},
{
"db": "CNNVD",
"id": "CNNVD-201306-249"
}
]
},
"id": "VAR-201306-0316",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "IVD",
"id": "e694e1ea-2352-11e6-abef-000c29c66e3d"
},
{
"db": "CNVD",
"id": "CNVD-2013-07608"
},
{
"db": "VULHUB",
"id": "VHN-63961"
}
],
"trust": 1.49052891
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"ICS"
],
"sub_category": null,
"trust": 0.8
}
],
"sources": [
{
"db": "IVD",
"id": "e694e1ea-2352-11e6-abef-000c29c66e3d"
},
{
"db": "CNVD",
"id": "CNVD-2013-07608"
}
]
},
"last_update_date": "2023-12-18T13:09:31.178000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "SSA-345843: Vulnerabilites in WinCC 7.2",
"trust": 0.8,
"url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345843.pdf"
},
{
"title": "Siemens SIMATIC WinCC/PCS 7 User Name Enumeration Patch",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchinfo/show/34668"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2013-07608"
},
{
"db": "JVNDB",
"id": "JVNDB-2013-002984"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-200",
"trust": 1.9
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-63961"
},
{
"db": "JVNDB",
"id": "JVNDB-2013-002984"
},
{
"db": "NVD",
"id": "CVE-2013-3959"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.0,
"url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345843.pdf"
},
{
"trust": 1.1,
"url": "https://ics-cert.us-cert.gov/advisories/icsa-13-169-02"
},
{
"trust": 0.8,
"url": "http://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2013-3959"
},
{
"trust": 0.8,
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnid=cve-2013-3959"
},
{
"trust": 0.6,
"url": "http://secunia.com/advisories/53805/"
},
{
"trust": 0.6,
"url": "http://secunia.com/advisories/53805"
},
{
"trust": 0.3,
"url": "http://www.siemens.com/"
},
{
"trust": 0.3,
"url": "http://www.automation.siemens.com/mcms/human-machine-interface/en/visualization-software/scada/simatic-wincc/pages/default.aspx"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2013-07608"
},
{
"db": "VULHUB",
"id": "VHN-63961"
},
{
"db": "BID",
"id": "60559"
},
{
"db": "JVNDB",
"id": "JVNDB-2013-002984"
},
{
"db": "NVD",
"id": "CVE-2013-3959"
},
{
"db": "CNNVD",
"id": "CNNVD-201306-249"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "IVD",
"id": "e694e1ea-2352-11e6-abef-000c29c66e3d"
},
{
"db": "CNVD",
"id": "CNVD-2013-07608"
},
{
"db": "VULHUB",
"id": "VHN-63961"
},
{
"db": "BID",
"id": "60559"
},
{
"db": "JVNDB",
"id": "JVNDB-2013-002984"
},
{
"db": "NVD",
"id": "CVE-2013-3959"
},
{
"db": "CNNVD",
"id": "CNNVD-201306-249"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2013-06-19T00:00:00",
"db": "IVD",
"id": "e694e1ea-2352-11e6-abef-000c29c66e3d"
},
{
"date": "2013-06-19T00:00:00",
"db": "CNVD",
"id": "CNVD-2013-07608"
},
{
"date": "2013-06-14T00:00:00",
"db": "VULHUB",
"id": "VHN-63961"
},
{
"date": "2013-06-14T00:00:00",
"db": "BID",
"id": "60559"
},
{
"date": "2013-06-18T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2013-002984"
},
{
"date": "2013-06-14T19:55:01.270000",
"db": "NVD",
"id": "CVE-2013-3959"
},
{
"date": "2013-06-18T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201306-249"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2013-06-19T00:00:00",
"db": "CNVD",
"id": "CNVD-2013-07608"
},
{
"date": "2013-06-17T00:00:00",
"db": "VULHUB",
"id": "VHN-63961"
},
{
"date": "2015-03-19T09:11:00",
"db": "BID",
"id": "60559"
},
{
"date": "2013-06-25T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2013-002984"
},
{
"date": "2013-06-17T04:00:00",
"db": "NVD",
"id": "CVE-2013-3959"
},
{
"date": "2013-06-18T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201306-249"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201306-249"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Siemens SIMATIC WinCC/PCS 7 User Name Enumeration Vulnerability",
"sources": [
{
"db": "IVD",
"id": "e694e1ea-2352-11e6-abef-000c29c66e3d"
},
{
"db": "CNVD",
"id": "CNVD-2013-07608"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "information disclosure",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201306-249"
}
],
"trust": 0.6
}
}
VAR-201306-0315
Vulnerability from variot - Updated: 2023-12-18 13:09The login implementation in the Web Navigator in Siemens WinCC before 7.2 Update 1, as used in SIMATIC PCS7 8.0 SP1 and earlier and other products, has a hardcoded account, which makes it easier for remote attackers to obtain access via an unspecified request. Siemens SIMATIC WinCC is a monitoring control and data acquisition SCADA and human machine interface HMI system. Siemens SIMATIC PCS is a process control system. An attacker can exploit the vulnerability to gain access. The vulnerability is due to the fact that the program has hard-coded accounts
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-201306-0315",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "wincc",
"scope": "eq",
"trust": 1.6,
"vendor": "siemens",
"version": "7.0"
},
{
"model": "wincc",
"scope": "eq",
"trust": 1.6,
"vendor": "siemens",
"version": "7.1"
},
{
"model": "simatic pcs7",
"scope": "eq",
"trust": 1.6,
"vendor": "siemens",
"version": "8.0"
},
{
"model": "simatic pcs7",
"scope": "lte",
"trust": 1.0,
"vendor": "siemens",
"version": "8.0"
},
{
"model": "wincc",
"scope": "lte",
"trust": 1.0,
"vendor": "siemens",
"version": "7.2"
},
{
"model": null,
"scope": "eq",
"trust": 0.8,
"vendor": "wincc",
"version": "7.0"
},
{
"model": "simatic pcs 7",
"scope": "lte",
"trust": 0.8,
"vendor": "siemens",
"version": "8.0 sp1"
},
{
"model": "simatic wincc",
"scope": "lt",
"trust": 0.8,
"vendor": "siemens",
"version": "7.2 update 1"
},
{
"model": "simatic wincc",
"scope": "eq",
"trust": 0.6,
"vendor": "siemens",
"version": "7.x"
},
{
"model": "simatic pcs",
"scope": "eq",
"trust": 0.6,
"vendor": "siemens",
"version": "78.x"
},
{
"model": "wincc",
"scope": "eq",
"trust": 0.6,
"vendor": "siemens",
"version": "7.2"
},
{
"model": null,
"scope": "eq",
"trust": 0.4,
"vendor": "wincc",
"version": "7.1"
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "simatic pcs7",
"version": "8.0"
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "simatic pcs7",
"version": "*"
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "wincc",
"version": "*"
}
],
"sources": [
{
"db": "IVD",
"id": "e69a1ca0-2352-11e6-abef-000c29c66e3d"
},
{
"db": "CNVD",
"id": "CNVD-2013-07606"
},
{
"db": "JVNDB",
"id": "JVNDB-2013-002983"
},
{
"db": "NVD",
"id": "CVE-2013-3958"
},
{
"db": "CNNVD",
"id": "CNNVD-201306-248"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:a:siemens:simatic_pcs7:8.0:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:simatic_pcs7:*:sp1:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "8.0",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:wincc:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "7.2",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:wincc:7.0:sp3:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:wincc:7.0:sp2:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:wincc:7.0:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:wincc:7.1:sp1:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:wincc:7.0:sp1:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:wincc:7.1:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2013-3958"
}
]
},
"credits": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/credits#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Alexander Tlyapov from Positive Technologies",
"sources": [
{
"db": "BID",
"id": "60561"
}
],
"trust": 0.3
},
"cve": "CVE-2013-3958",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"acInsufInfo": false,
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "NVD",
"availabilityImpact": "PARTIAL",
"baseScore": 7.5,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 10.0,
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "HIGH",
"trust": 1.0,
"userInteractionRequired": false,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
{
"acInsufInfo": null,
"accessComplexity": "Low",
"accessVector": "Network",
"authentication": "None",
"author": "NVD",
"availabilityImpact": "Partial",
"baseScore": 7.5,
"confidentialityImpact": "Partial",
"exploitabilityScore": null,
"id": "CVE-2013-3958",
"impactScore": null,
"integrityImpact": "Partial",
"obtainAllPrivilege": null,
"obtainOtherPrivilege": null,
"obtainUserPrivilege": null,
"severity": "High",
"trust": 0.8,
"userInteractionRequired": null,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "PARTIAL",
"baseScore": 7.5,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 10.0,
"id": "CNVD-2013-07606",
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "IVD",
"availabilityImpact": "PARTIAL",
"baseScore": 7.5,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 10.0,
"id": "e69a1ca0-2352-11e6-abef-000c29c66e3d",
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"severity": "HIGH",
"trust": 0.2,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.9 [IVD]"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "VULHUB",
"availabilityImpact": "PARTIAL",
"baseScore": 7.5,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 10.0,
"id": "VHN-63960",
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"severity": "HIGH",
"trust": 0.1,
"vectorString": "AV:N/AC:L/AU:N/C:P/I:P/A:P",
"version": "2.0"
}
],
"cvssV3": [],
"severity": [
{
"author": "NVD",
"id": "CVE-2013-3958",
"trust": 1.8,
"value": "HIGH"
},
{
"author": "CNVD",
"id": "CNVD-2013-07606",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "CNNVD",
"id": "CNNVD-201306-248",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "IVD",
"id": "e69a1ca0-2352-11e6-abef-000c29c66e3d",
"trust": 0.2,
"value": "HIGH"
},
{
"author": "VULHUB",
"id": "VHN-63960",
"trust": 0.1,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "IVD",
"id": "e69a1ca0-2352-11e6-abef-000c29c66e3d"
},
{
"db": "CNVD",
"id": "CNVD-2013-07606"
},
{
"db": "VULHUB",
"id": "VHN-63960"
},
{
"db": "JVNDB",
"id": "JVNDB-2013-002983"
},
{
"db": "NVD",
"id": "CVE-2013-3958"
},
{
"db": "CNNVD",
"id": "CNNVD-201306-248"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "The login implementation in the Web Navigator in Siemens WinCC before 7.2 Update 1, as used in SIMATIC PCS7 8.0 SP1 and earlier and other products, has a hardcoded account, which makes it easier for remote attackers to obtain access via an unspecified request. Siemens SIMATIC WinCC is a monitoring control and data acquisition SCADA and human machine interface HMI system. Siemens SIMATIC PCS is a process control system. An attacker can exploit the vulnerability to gain access. The vulnerability is due to the fact that the program has hard-coded accounts",
"sources": [
{
"db": "NVD",
"id": "CVE-2013-3958"
},
{
"db": "JVNDB",
"id": "JVNDB-2013-002983"
},
{
"db": "CNVD",
"id": "CNVD-2013-07606"
},
{
"db": "BID",
"id": "60561"
},
{
"db": "IVD",
"id": "e69a1ca0-2352-11e6-abef-000c29c66e3d"
},
{
"db": "VULHUB",
"id": "VHN-63960"
}
],
"trust": 2.7
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2013-3958",
"trust": 3.6
},
{
"db": "SIEMENS",
"id": "SSA-345843",
"trust": 1.7
},
{
"db": "SECUNIA",
"id": "53805",
"trust": 1.2
},
{
"db": "BID",
"id": "60561",
"trust": 1.0
},
{
"db": "CNNVD",
"id": "CNNVD-201306-248",
"trust": 0.9
},
{
"db": "CNVD",
"id": "CNVD-2013-07606",
"trust": 0.8
},
{
"db": "ICS CERT",
"id": "ICSA-13-169-02",
"trust": 0.8
},
{
"db": "JVNDB",
"id": "JVNDB-2013-002983",
"trust": 0.8
},
{
"db": "IVD",
"id": "E69A1CA0-2352-11E6-ABEF-000C29C66E3D",
"trust": 0.2
},
{
"db": "VULHUB",
"id": "VHN-63960",
"trust": 0.1
}
],
"sources": [
{
"db": "IVD",
"id": "e69a1ca0-2352-11e6-abef-000c29c66e3d"
},
{
"db": "CNVD",
"id": "CNVD-2013-07606"
},
{
"db": "VULHUB",
"id": "VHN-63960"
},
{
"db": "BID",
"id": "60561"
},
{
"db": "JVNDB",
"id": "JVNDB-2013-002983"
},
{
"db": "NVD",
"id": "CVE-2013-3958"
},
{
"db": "CNNVD",
"id": "CNNVD-201306-248"
}
]
},
"id": "VAR-201306-0315",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "IVD",
"id": "e69a1ca0-2352-11e6-abef-000c29c66e3d"
},
{
"db": "CNVD",
"id": "CNVD-2013-07606"
},
{
"db": "VULHUB",
"id": "VHN-63960"
}
],
"trust": 1.49052891
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"ICS"
],
"sub_category": null,
"trust": 0.8
}
],
"sources": [
{
"db": "IVD",
"id": "e69a1ca0-2352-11e6-abef-000c29c66e3d"
},
{
"db": "CNVD",
"id": "CNVD-2013-07606"
}
]
},
"last_update_date": "2023-12-18T13:09:31.141000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "SSA-345843: Vulnerabilites in WinCC 7.2",
"trust": 0.8,
"url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345843.pdf"
},
{
"title": "\\302\\240Siemens SIMATIC WinCC/PCS 7 Hardcoded Credential Security Bypass Vulnerability Patch",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchinfo/show/34666"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2013-07606"
},
{
"db": "JVNDB",
"id": "JVNDB-2013-002983"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-255",
"trust": 1.9
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-63960"
},
{
"db": "JVNDB",
"id": "JVNDB-2013-002983"
},
{
"db": "NVD",
"id": "CVE-2013-3958"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.7,
"url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345843.pdf"
},
{
"trust": 0.8,
"url": "http://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2013-3958"
},
{
"trust": 0.8,
"url": "https://ics-cert.us-cert.gov/advisories/icsa-13-169-02"
},
{
"trust": 0.8,
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnid=cve-2013-3958"
},
{
"trust": 0.6,
"url": "http://secunia.com/advisories/53805/"
},
{
"trust": 0.6,
"url": "http://secunia.com/advisories/53805"
},
{
"trust": 0.3,
"url": "http://subscriber.communications.siemens.com/"
},
{
"trust": 0.3,
"url": "http://aunz.siemens.com/newscentre/productreleases/pages/iac_pr_simaticwinccv62.aspx"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2013-07606"
},
{
"db": "VULHUB",
"id": "VHN-63960"
},
{
"db": "BID",
"id": "60561"
},
{
"db": "JVNDB",
"id": "JVNDB-2013-002983"
},
{
"db": "NVD",
"id": "CVE-2013-3958"
},
{
"db": "CNNVD",
"id": "CNNVD-201306-248"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "IVD",
"id": "e69a1ca0-2352-11e6-abef-000c29c66e3d"
},
{
"db": "CNVD",
"id": "CNVD-2013-07606"
},
{
"db": "VULHUB",
"id": "VHN-63960"
},
{
"db": "BID",
"id": "60561"
},
{
"db": "JVNDB",
"id": "JVNDB-2013-002983"
},
{
"db": "NVD",
"id": "CVE-2013-3958"
},
{
"db": "CNNVD",
"id": "CNNVD-201306-248"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2013-06-19T00:00:00",
"db": "IVD",
"id": "e69a1ca0-2352-11e6-abef-000c29c66e3d"
},
{
"date": "2013-06-19T00:00:00",
"db": "CNVD",
"id": "CNVD-2013-07606"
},
{
"date": "2013-06-14T00:00:00",
"db": "VULHUB",
"id": "VHN-63960"
},
{
"date": "2013-06-14T00:00:00",
"db": "BID",
"id": "60561"
},
{
"date": "2013-06-18T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2013-002983"
},
{
"date": "2013-06-14T19:55:01.250000",
"db": "NVD",
"id": "CVE-2013-3958"
},
{
"date": "2013-06-18T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201306-248"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2013-06-19T00:00:00",
"db": "CNVD",
"id": "CNVD-2013-07606"
},
{
"date": "2013-06-17T00:00:00",
"db": "VULHUB",
"id": "VHN-63960"
},
{
"date": "2013-06-19T07:17:00",
"db": "BID",
"id": "60561"
},
{
"date": "2013-06-25T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2013-002983"
},
{
"date": "2013-06-17T04:00:00",
"db": "NVD",
"id": "CVE-2013-3958"
},
{
"date": "2013-06-21T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201306-248"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201306-248"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Siemens SIMATIC WinCC/PCS 7 Hardcoded Credential Security Bypass Vulnerability",
"sources": [
{
"db": "IVD",
"id": "e69a1ca0-2352-11e6-abef-000c29c66e3d"
},
{
"db": "CNVD",
"id": "CNVD-2013-07606"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Trust management",
"sources": [
{
"db": "IVD",
"id": "e69a1ca0-2352-11e6-abef-000c29c66e3d"
},
{
"db": "CNNVD",
"id": "CNNVD-201306-248"
}
],
"trust": 0.8
}
}
VAR-201306-0314
Vulnerability from variot - Updated: 2023-12-18 13:09SQL injection vulnerability in the login screen in the Web Navigator in Siemens WinCC before 7.2 Update 1, as used in SIMATIC PCS7 8.0 SP1 and earlier and other products, allows remote attackers to execute arbitrary SQL commands via unspecified vectors. Siemens SIMATIC WinCC is a monitoring control and data acquisition SCADA and human machine interface HMI system. Siemens SIMATIC PCS is a process control system. By operating the database, remote attackers can exploit this vulnerability to enhance their permissions. Depending on the system configuration, it is possible to obtain full system access rights and execute. Any SQL command
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-201306-0314",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "wincc",
"scope": "eq",
"trust": 1.6,
"vendor": "siemens",
"version": "7.0"
},
{
"model": "wincc",
"scope": "eq",
"trust": 1.6,
"vendor": "siemens",
"version": "7.1"
},
{
"model": "simatic pcs7",
"scope": "eq",
"trust": 1.6,
"vendor": "siemens",
"version": "8.0"
},
{
"model": "simatic pcs7",
"scope": "lte",
"trust": 1.0,
"vendor": "siemens",
"version": "8.0"
},
{
"model": "wincc",
"scope": "lte",
"trust": 1.0,
"vendor": "siemens",
"version": "7.2"
},
{
"model": null,
"scope": "eq",
"trust": 0.8,
"vendor": "wincc",
"version": "7.0"
},
{
"model": "simatic pcs 7",
"scope": "lte",
"trust": 0.8,
"vendor": "siemens",
"version": "8.0 sp1"
},
{
"model": "simatic wincc",
"scope": "lt",
"trust": 0.8,
"vendor": "siemens",
"version": "7.2 update 1"
},
{
"model": "simatic wincc",
"scope": "eq",
"trust": 0.6,
"vendor": "siemens",
"version": "7.x"
},
{
"model": "simatic pcs",
"scope": "eq",
"trust": 0.6,
"vendor": "siemens",
"version": "78.x"
},
{
"model": "wincc",
"scope": "eq",
"trust": 0.6,
"vendor": "siemens",
"version": "7.2"
},
{
"model": null,
"scope": "eq",
"trust": 0.4,
"vendor": "wincc",
"version": "7.1"
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "simatic pcs7",
"version": "8.0"
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "simatic pcs7",
"version": "*"
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "wincc",
"version": "*"
}
],
"sources": [
{
"db": "IVD",
"id": "e6a420b0-2352-11e6-abef-000c29c66e3d"
},
{
"db": "CNVD",
"id": "CNVD-2013-07609"
},
{
"db": "JVNDB",
"id": "JVNDB-2013-002982"
},
{
"db": "NVD",
"id": "CVE-2013-3957"
},
{
"db": "CNNVD",
"id": "CNNVD-201306-247"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:a:siemens:wincc:7.0:sp3:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:wincc:7.0:sp2:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:wincc:7.0:sp1:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:wincc:7.0:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:wincc:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "7.2",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:wincc:7.1:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:simatic_pcs7:8.0:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:wincc:7.1:sp1:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:simatic_pcs7:*:sp1:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "8.0",
"vulnerable": true
}
],
"operator": "OR"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2013-3957"
}
]
},
"credits": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/credits#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Alexander Tlyapov from Positive Technologies",
"sources": [
{
"db": "BID",
"id": "60558"
}
],
"trust": 0.3
},
"cve": "CVE-2013-3957",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"acInsufInfo": false,
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "NVD",
"availabilityImpact": "PARTIAL",
"baseScore": 7.5,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 10.0,
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "HIGH",
"trust": 1.0,
"userInteractionRequired": false,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
{
"acInsufInfo": null,
"accessComplexity": "Low",
"accessVector": "Network",
"authentication": "None",
"author": "NVD",
"availabilityImpact": "Partial",
"baseScore": 7.5,
"confidentialityImpact": "Partial",
"exploitabilityScore": null,
"id": "CVE-2013-3957",
"impactScore": null,
"integrityImpact": "Partial",
"obtainAllPrivilege": null,
"obtainOtherPrivilege": null,
"obtainUserPrivilege": null,
"severity": "High",
"trust": 0.8,
"userInteractionRequired": null,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "PARTIAL",
"baseScore": 7.5,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 10.0,
"id": "CNVD-2013-07609",
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "IVD",
"availabilityImpact": "PARTIAL",
"baseScore": 7.5,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 10.0,
"id": "e6a420b0-2352-11e6-abef-000c29c66e3d",
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"severity": "HIGH",
"trust": 0.2,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.9 [IVD]"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "VULHUB",
"availabilityImpact": "PARTIAL",
"baseScore": 7.5,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 10.0,
"id": "VHN-63959",
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"severity": "HIGH",
"trust": 0.1,
"vectorString": "AV:N/AC:L/AU:N/C:P/I:P/A:P",
"version": "2.0"
}
],
"cvssV3": [],
"severity": [
{
"author": "NVD",
"id": "CVE-2013-3957",
"trust": 1.8,
"value": "HIGH"
},
{
"author": "CNVD",
"id": "CNVD-2013-07609",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "CNNVD",
"id": "CNNVD-201306-247",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "IVD",
"id": "e6a420b0-2352-11e6-abef-000c29c66e3d",
"trust": 0.2,
"value": "HIGH"
},
{
"author": "VULHUB",
"id": "VHN-63959",
"trust": 0.1,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "IVD",
"id": "e6a420b0-2352-11e6-abef-000c29c66e3d"
},
{
"db": "CNVD",
"id": "CNVD-2013-07609"
},
{
"db": "VULHUB",
"id": "VHN-63959"
},
{
"db": "JVNDB",
"id": "JVNDB-2013-002982"
},
{
"db": "NVD",
"id": "CVE-2013-3957"
},
{
"db": "CNNVD",
"id": "CNNVD-201306-247"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "SQL injection vulnerability in the login screen in the Web Navigator in Siemens WinCC before 7.2 Update 1, as used in SIMATIC PCS7 8.0 SP1 and earlier and other products, allows remote attackers to execute arbitrary SQL commands via unspecified vectors. Siemens SIMATIC WinCC is a monitoring control and data acquisition SCADA and human machine interface HMI system. Siemens SIMATIC PCS is a process control system. By operating the database, remote attackers can exploit this vulnerability to enhance their permissions. Depending on the system configuration, it is possible to obtain full system access rights and execute. Any SQL command",
"sources": [
{
"db": "NVD",
"id": "CVE-2013-3957"
},
{
"db": "JVNDB",
"id": "JVNDB-2013-002982"
},
{
"db": "CNVD",
"id": "CNVD-2013-07609"
},
{
"db": "BID",
"id": "60558"
},
{
"db": "IVD",
"id": "e6a420b0-2352-11e6-abef-000c29c66e3d"
},
{
"db": "VULHUB",
"id": "VHN-63959"
}
],
"trust": 2.7
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2013-3957",
"trust": 3.6
},
{
"db": "SIEMENS",
"id": "SSA-345843",
"trust": 1.7
},
{
"db": "SECUNIA",
"id": "53805",
"trust": 1.2
},
{
"db": "BID",
"id": "60558",
"trust": 1.0
},
{
"db": "CNVD",
"id": "CNVD-2013-07609",
"trust": 0.8
},
{
"db": "CNNVD",
"id": "CNNVD-201306-247",
"trust": 0.8
},
{
"db": "JVNDB",
"id": "JVNDB-2013-002982",
"trust": 0.8
},
{
"db": "IVD",
"id": "E6A420B0-2352-11E6-ABEF-000C29C66E3D",
"trust": 0.2
},
{
"db": "VULHUB",
"id": "VHN-63959",
"trust": 0.1
}
],
"sources": [
{
"db": "IVD",
"id": "e6a420b0-2352-11e6-abef-000c29c66e3d"
},
{
"db": "CNVD",
"id": "CNVD-2013-07609"
},
{
"db": "VULHUB",
"id": "VHN-63959"
},
{
"db": "BID",
"id": "60558"
},
{
"db": "JVNDB",
"id": "JVNDB-2013-002982"
},
{
"db": "NVD",
"id": "CVE-2013-3957"
},
{
"db": "CNNVD",
"id": "CNNVD-201306-247"
}
]
},
"id": "VAR-201306-0314",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "IVD",
"id": "e6a420b0-2352-11e6-abef-000c29c66e3d"
},
{
"db": "CNVD",
"id": "CNVD-2013-07609"
},
{
"db": "VULHUB",
"id": "VHN-63959"
}
],
"trust": 1.49052891
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"ICS"
],
"sub_category": null,
"trust": 0.8
}
],
"sources": [
{
"db": "IVD",
"id": "e6a420b0-2352-11e6-abef-000c29c66e3d"
},
{
"db": "CNVD",
"id": "CNVD-2013-07609"
}
]
},
"last_update_date": "2023-12-18T13:09:31.214000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "SSA-345843: Vulnerabilites in WinCC 7.2",
"trust": 0.8,
"url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345843.pdf"
},
{
"title": "Patch for Siemens SIMATIC WinCC/PCS 7 SQL Injection Vulnerability",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchinfo/show/34669"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2013-07609"
},
{
"db": "JVNDB",
"id": "JVNDB-2013-002982"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-89",
"trust": 1.9
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-63959"
},
{
"db": "JVNDB",
"id": "JVNDB-2013-002982"
},
{
"db": "NVD",
"id": "CVE-2013-3957"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.7,
"url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345843.pdf"
},
{
"trust": 0.8,
"url": "http://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2013-3957"
},
{
"trust": 0.8,
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnid=cve-2013-3957"
},
{
"trust": 0.6,
"url": "http://secunia.com/advisories/53805/"
},
{
"trust": 0.6,
"url": "http://secunia.com/advisories/53805"
},
{
"trust": 0.3,
"url": "http://subscriber.communications.siemens.com/"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2013-07609"
},
{
"db": "VULHUB",
"id": "VHN-63959"
},
{
"db": "BID",
"id": "60558"
},
{
"db": "JVNDB",
"id": "JVNDB-2013-002982"
},
{
"db": "NVD",
"id": "CVE-2013-3957"
},
{
"db": "CNNVD",
"id": "CNNVD-201306-247"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "IVD",
"id": "e6a420b0-2352-11e6-abef-000c29c66e3d"
},
{
"db": "CNVD",
"id": "CNVD-2013-07609"
},
{
"db": "VULHUB",
"id": "VHN-63959"
},
{
"db": "BID",
"id": "60558"
},
{
"db": "JVNDB",
"id": "JVNDB-2013-002982"
},
{
"db": "NVD",
"id": "CVE-2013-3957"
},
{
"db": "CNNVD",
"id": "CNNVD-201306-247"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2013-06-19T00:00:00",
"db": "IVD",
"id": "e6a420b0-2352-11e6-abef-000c29c66e3d"
},
{
"date": "2013-06-19T00:00:00",
"db": "CNVD",
"id": "CNVD-2013-07609"
},
{
"date": "2013-06-14T00:00:00",
"db": "VULHUB",
"id": "VHN-63959"
},
{
"date": "2013-06-14T00:00:00",
"db": "BID",
"id": "60558"
},
{
"date": "2013-06-18T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2013-002982"
},
{
"date": "2013-06-14T19:55:01.233000",
"db": "NVD",
"id": "CVE-2013-3957"
},
{
"date": "2013-06-18T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201306-247"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2013-06-19T00:00:00",
"db": "CNVD",
"id": "CNVD-2013-07609"
},
{
"date": "2013-06-17T00:00:00",
"db": "VULHUB",
"id": "VHN-63959"
},
{
"date": "2015-03-19T08:17:00",
"db": "BID",
"id": "60558"
},
{
"date": "2013-06-18T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2013-002982"
},
{
"date": "2013-06-17T04:00:00",
"db": "NVD",
"id": "CVE-2013-3957"
},
{
"date": "2013-07-11T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201306-247"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201306-247"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "SIMATIC PCS 7 Used in Siemens WinCC of Web Navigator In SQL Injection vulnerability",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2013-002982"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "SQL injection",
"sources": [
{
"db": "IVD",
"id": "e6a420b0-2352-11e6-abef-000c29c66e3d"
},
{
"db": "CNNVD",
"id": "CNNVD-201306-247"
}
],
"trust": 0.8
}
}
VAR-201611-0180
Vulnerability from variot - Updated: 2023-12-18 13:09A vulnerability has been identified in Primary Setup Tool (PST) (All versions < V4.2 HF1), SIMATIC IT Production Suite (All versions < V7.0 SP1 HFX 2), SIMATIC NET PC-Software (All versions < V14), SIMATIC PCS 7 V7.1 (All versions), SIMATIC PCS 7 V8.0 (All versions), SIMATIC PCS 7 V8.1 (All versions), SIMATIC PCS 7 V8.2 (All versions < V8.2 SP1), SIMATIC STEP 7 (TIA Portal) V13 (All versions < V13 SP2), SIMATIC STEP 7 V5.X (All versions < V5.5 SP4 HF11), SIMATIC WinCC (TIA Portal) Basic, Comfort, Advanced (All versions < V14), SIMATIC WinCC (TIA Portal) Professional V13 (All versions < V13 SP2), SIMATIC WinCC (TIA Portal) Professional V14 (All versions < V14 SP1), SIMATIC WinCC Runtime Professional V13 (All versions < V13 SP2), SIMATIC WinCC Runtime Professional V14 (All versions < V14 SP1), SIMATIC WinCC V7.0 SP2 and earlier versions (All versions < V7.0 SP2 Upd 12), SIMATIC WinCC V7.0 SP3 (All versions < V7.0 SP3 Upd 8), SIMATIC WinCC V7.2 (All versions < V7.2 Upd 14), SIMATIC WinCC V7.3 (All versions < V7.3 Upd 11), SIMATIC WinCC V7.4 (All versions < V7.4 SP1), SIMIT V9.0 (All versions < V9.0 SP1), SINEMA Remote Connect Client (All versions < V1.0 SP3), SINEMA Server (All versions < V13 SP2), SOFTNET Security Client V5.0 (All versions), Security Configuration Tool (SCT) (All versions < V4.3 HF1), TeleControl Server Basic (All versions < V3.0 SP2), WinAC RTX 2010 SP2 (All versions), WinAC RTX F 2010 SP2 (All versions). Unquoted service paths could allow local Microsoft Windows operating system users to escalate their privileges if the affected products are not installed under their default path ("C:\Program Files*" or the localized equivalent). plural Siemens The product has an installation %PROGRAMFILES% If not using a directory, it is not enclosed in quotes Windows There are vulnerabilities whose privileges are obtained by the search path. Supplementary information : CWE Vulnerability type by CWE-254: Security Features ( Security function ) ,and CWE-284: Improper Access Control ( Inappropriate access control ) Has been identified. https://cwe.mitre.org/data/definitions/254.html https://cwe.mitre.org/data/definitions/284.htmlA local user may be able to gain privileges through the Trojan executable. Founded in 1847, Siemens AG of Germany focuses on the fields of electrification, automation and digitization. Siemens is a leader in offshore wind turbine construction, gas turbine and steam turbine power generation, transmission solutions, infrastructure solutions, industrial automation, drive and software solutions, and medical imaging equipment and laboratory diagnostics. There are privilege escalation vulnerabilities in many Siemens products. Siemens SIMATIC WinCC, etc. Siemens SIMATIC WinCC is an automated data acquisition and monitoring (SCADA) system; SIMATIC PCS 7 is a distributed process control system using WinCC
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-201611-0180",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "simit",
"scope": "eq",
"trust": 3.3,
"vendor": "siemens",
"version": "9.0"
},
{
"model": "softnet security client",
"scope": "eq",
"trust": 1.7,
"vendor": "siemens",
"version": "5.0"
},
{
"model": "simatic wincc runtime",
"scope": "eq",
"trust": 1.6,
"vendor": "siemens",
"version": null
},
{
"model": "simatic wincc \\",
"scope": "eq",
"trust": 1.6,
"vendor": "siemens",
"version": null
},
{
"model": "sinema remote connect",
"scope": "eq",
"trust": 1.6,
"vendor": "siemens",
"version": null
},
{
"model": "simatic wincc",
"scope": "eq",
"trust": 1.3,
"vendor": "siemens",
"version": "7.4"
},
{
"model": "simatic wincc",
"scope": "eq",
"trust": 1.3,
"vendor": "siemens",
"version": "7.3"
},
{
"model": "simatic wincc",
"scope": "eq",
"trust": 1.3,
"vendor": "siemens",
"version": "7.2"
},
{
"model": "sinema server",
"scope": "lte",
"trust": 1.0,
"vendor": "siemens",
"version": "13.0"
},
{
"model": "simatic pcs 7",
"scope": "lte",
"trust": 1.0,
"vendor": "siemens",
"version": "7.1"
},
{
"model": "simatic wincc \\",
"scope": "lte",
"trust": 1.0,
"vendor": "siemens",
"version": "14.0"
},
{
"model": "simatic wincc",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "7.0"
},
{
"model": "simatic net pc software",
"scope": "lte",
"trust": 1.0,
"vendor": "siemens",
"version": "14.0"
},
{
"model": "simatic step 7",
"scope": "lte",
"trust": 1.0,
"vendor": "siemens",
"version": "5.5"
},
{
"model": "telecontrol basic",
"scope": "lte",
"trust": 1.0,
"vendor": "siemens",
"version": "3.0"
},
{
"model": "primary setup tool",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "simatic pcs7",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "8.2"
},
{
"model": "security configuration tool",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "simatic pcs7",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "8.1"
},
{
"model": "simatic pcs7",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "8.0"
},
{
"model": "simatic winac rtx 2010",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "simatic step 7 \\",
"scope": "lte",
"trust": 1.0,
"vendor": "siemens",
"version": "14.0"
},
{
"model": "softnet security client",
"scope": "lte",
"trust": 1.0,
"vendor": "siemens",
"version": "5.0"
},
{
"model": "simatic winac rtx f 2010",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "simatic wincc",
"scope": "lte",
"trust": 1.0,
"vendor": "siemens",
"version": "7.0"
},
{
"model": "simatic it production suite",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "simatic pcs",
"scope": "eq",
"trust": 0.9,
"vendor": "siemens",
"version": "78.0"
},
{
"model": "simatic pcs",
"scope": "eq",
"trust": 0.9,
"vendor": "siemens",
"version": "78.1"
},
{
"model": "simatic pcs",
"scope": "eq",
"trust": 0.9,
"vendor": "siemens",
"version": "78.2"
},
{
"model": "security configuration tool",
"scope": null,
"trust": 0.8,
"vendor": "siemens",
"version": null
},
{
"model": "simatic winac rtx f 2010",
"scope": "eq",
"trust": 0.8,
"vendor": "siemens",
"version": "sp2"
},
{
"model": "simatic it production suite",
"scope": null,
"trust": 0.8,
"vendor": "siemens",
"version": null
},
{
"model": "simatic wincc",
"scope": "lt",
"trust": 0.8,
"vendor": "siemens",
"version": "7.0 sp3"
},
{
"model": "simatic winac rtx 2010",
"scope": "eq",
"trust": 0.8,
"vendor": "siemens",
"version": "sp2"
},
{
"model": "simatic wincc",
"scope": "eq",
"trust": 0.8,
"vendor": "siemens",
"version": "professional"
},
{
"model": "simatic pcs 7",
"scope": "lte",
"trust": 0.8,
"vendor": "siemens",
"version": "8.2 until"
},
{
"model": "simatic wincc runtime professional",
"scope": null,
"trust": 0.8,
"vendor": "siemens",
"version": null
},
{
"model": "simatic wincc",
"scope": "eq",
"trust": 0.8,
"vendor": "siemens",
"version": "7.2 to 7.4"
},
{
"model": "sinema remote connect client",
"scope": null,
"trust": 0.8,
"vendor": "siemens",
"version": null
},
{
"model": "simatic wincc",
"scope": "eq",
"trust": 0.8,
"vendor": "siemens",
"version": "7.0 sp3 upd 8"
},
{
"model": "simatic step 7",
"scope": "eq",
"trust": 0.8,
"vendor": "siemens",
"version": "5.x"
},
{
"model": "primary setup tool",
"scope": null,
"trust": 0.8,
"vendor": "siemens",
"version": null
},
{
"model": null,
"scope": "eq",
"trust": 0.6,
"vendor": "simatic wincc tia portal",
"version": "*"
},
{
"model": "simatic step",
"scope": "eq",
"trust": 0.6,
"vendor": "siemens",
"version": "75.x"
},
{
"model": "simatic wincc",
"scope": "eq",
"trust": 0.6,
"vendor": "siemens",
"version": "7.3x"
},
{
"model": "simatic wincc",
"scope": "eq",
"trust": 0.6,
"vendor": "siemens",
"version": "7.4x"
},
{
"model": "sinema server",
"scope": null,
"trust": 0.6,
"vendor": "siemens",
"version": null
},
{
"model": "simatic wincc",
"scope": "eq",
"trust": 0.6,
"vendor": "siemens",
"version": "7.2x"
},
{
"model": "simatic wincc sp2 sp2 upd",
"scope": "eq",
"trust": 0.6,
"vendor": "siemens",
"version": "7.0\u003c7.012"
},
{
"model": "simatic wincc sp3 sp3 upd",
"scope": "eq",
"trust": 0.6,
"vendor": "siemens",
"version": "7.0\u003c7.08"
},
{
"model": "simatic net pc-software",
"scope": "lt",
"trust": 0.6,
"vendor": "siemens",
"version": "14"
},
{
"model": "simatic wincc runtime professional all",
"scope": null,
"trust": 0.6,
"vendor": "siemens",
"version": null
},
{
"model": "simatic step",
"scope": "eq",
"trust": 0.6,
"vendor": "siemens",
"version": "7\u003c14"
},
{
"model": "simatic wincc basic",
"scope": "lt",
"trust": 0.6,
"vendor": "siemens",
"version": "14"
},
{
"model": "simatic wincc comfort",
"scope": "lt",
"trust": 0.6,
"vendor": "siemens",
"version": "14"
},
{
"model": "simatic wincc advanced",
"scope": "lt",
"trust": 0.6,
"vendor": "siemens",
"version": "14"
},
{
"model": "simatic wincc professional all",
"scope": null,
"trust": 0.6,
"vendor": "siemens",
"version": null
},
{
"model": "sinema remote connect client all",
"scope": null,
"trust": 0.6,
"vendor": "siemens",
"version": null
},
{
"model": "simatic winac rtx sp2 all",
"scope": "eq",
"trust": 0.6,
"vendor": "siemens",
"version": "2010"
},
{
"model": "simatic winac rtx f sp2 all",
"scope": "eq",
"trust": 0.6,
"vendor": "siemens",
"version": "2010"
},
{
"model": "simatic it production suite all",
"scope": null,
"trust": 0.6,
"vendor": "siemens",
"version": null
},
{
"model": "telecontrol server basic sp2",
"scope": "lt",
"trust": 0.6,
"vendor": "siemens",
"version": "3.0"
},
{
"model": "softnet security client all",
"scope": "eq",
"trust": 0.6,
"vendor": "siemens",
"version": "v5.0"
},
{
"model": "security configuration tool all",
"scope": null,
"trust": 0.6,
"vendor": "siemens",
"version": null
},
{
"model": "primary setup tool all",
"scope": null,
"trust": 0.6,
"vendor": "siemens",
"version": null
},
{
"model": "simatic wincc \\",
"scope": "eq",
"trust": 0.6,
"vendor": "siemens",
"version": "14.0"
},
{
"model": "telecontrol basic",
"scope": "eq",
"trust": 0.6,
"vendor": "siemens",
"version": "3.0"
},
{
"model": "sinema server",
"scope": "eq",
"trust": 0.6,
"vendor": "siemens",
"version": "13.0"
},
{
"model": "telecontrol server basic",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "3.0"
},
{
"model": "sinema server sp1",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "v12"
},
{
"model": "sinema server",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "v12"
},
{
"model": "sinema server sp1",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "12.0"
},
{
"model": "sinema server",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "12.0-"
},
{
"model": "sinema remote connect client",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "0"
},
{
"model": "simatic wincc runtime professional",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "0"
},
{
"model": "simatic wincc professional",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "0"
},
{
"model": "simatic wincc comfort",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "0"
},
{
"model": "simatic wincc basic",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "0"
},
{
"model": "simatic wincc advanced",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "0"
},
{
"model": "simatic wincc update",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "7.41"
},
{
"model": "simatic wincc update",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "7.32"
},
{
"model": "simatic wincc update",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "7.310"
},
{
"model": "simatic wincc update",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "7.31"
},
{
"model": "simatic wincc upd4",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "7.3"
},
{
"model": "simatic wincc update",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "7.29"
},
{
"model": "simatic wincc update",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "7.28"
},
{
"model": "simatic wincc update",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "7.21"
},
{
"model": "simatic wincc upd4",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "7.2"
},
{
"model": "simatic wincc upd11",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "7.2"
},
{
"model": "simatic wincc sp3",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "7.0"
},
{
"model": "simatic wincc sp2",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "7.0"
},
{
"model": "simatic winac rtx f sp2",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "2010"
},
{
"model": "simatic winac rtx sp2",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "2010"
},
{
"model": "simatic step tia portal sp1 upd1",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "7v13"
},
{
"model": "simatic step tia portal sp1",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "7v13"
},
{
"model": "simatic step tia portal",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "7v13"
},
{
"model": "simatic step tia portal",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "7v12"
},
{
"model": "simatic step sp4 hf4",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "75.5"
},
{
"model": "simatic step sp4",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "75.5"
},
{
"model": "simatic step sp3 hf10",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "75.5"
},
{
"model": "simatic step sp3",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "75.5"
},
{
"model": "simatic step sp2 hf7",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "75.5"
},
{
"model": "simatic step sp2",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "75.5"
},
{
"model": "simatic step sp1 hf2",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "75.5"
},
{
"model": "simatic step sp1",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "75.5"
},
{
"model": "simatic step",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "75.5"
},
{
"model": "simatic pcs sp1",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "78.1"
},
{
"model": "simatic pcs",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "78"
},
{
"model": "simatic pcs",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "77.1"
},
{
"model": "simatic pcs",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "77"
},
{
"model": "simatic net pc-software sp2",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "13"
},
{
"model": "simatic net pc-software hf1",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "13"
},
{
"model": "simatic net pc-software",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "13"
},
{
"model": "simatic net pc-software sp2 hf3",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "12"
},
{
"model": "simatic net pc-software",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "12"
},
{
"model": "simatic it production suite",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "0"
},
{
"model": "security configuration tool",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "0"
},
{
"model": "primary setup tool",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "0"
},
{
"model": "telecontrol server basic sp2",
"scope": "ne",
"trust": 0.3,
"vendor": "siemens",
"version": "3.0"
},
{
"model": "sinema server sp2",
"scope": "ne",
"trust": 0.3,
"vendor": "siemens",
"version": "13"
},
{
"model": "simatic wincc comfort",
"scope": "ne",
"trust": 0.3,
"vendor": "siemens",
"version": "14"
},
{
"model": "simatic wincc basic",
"scope": "ne",
"trust": 0.3,
"vendor": "siemens",
"version": "14"
},
{
"model": "simatic wincc advanced",
"scope": "ne",
"trust": 0.3,
"vendor": "siemens",
"version": "14"
},
{
"model": "simatic wincc sp3 upd",
"scope": "ne",
"trust": 0.3,
"vendor": "siemens",
"version": "7.08"
},
{
"model": "simatic wincc sp2 upd",
"scope": "ne",
"trust": 0.3,
"vendor": "siemens",
"version": "7.012"
},
{
"model": "simatic step tia portal",
"scope": "ne",
"trust": 0.3,
"vendor": "siemens",
"version": "7v14"
},
{
"model": "simatic net pc-software",
"scope": "ne",
"trust": 0.3,
"vendor": "siemens",
"version": "14"
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "primary setup tool",
"version": null
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "security configuration tool",
"version": null
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "simatic it production suite",
"version": null
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "simatic net pc",
"version": "*"
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "simatic pcs7",
"version": "8.0"
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "simatic pcs7",
"version": "8.1"
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "simatic pcs7",
"version": "8.2"
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "simatic pcs 7",
"version": "*"
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "simatic step 7",
"version": "*"
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "simatic step 7 tia portal",
"version": "*"
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "simatic winac rtx 2010",
"version": null
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "simatic winac rtx f 2010",
"version": null
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "simatic wincc",
"version": "*"
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "simatic wincc",
"version": "7.0"
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "simatic wincc",
"version": "7.2"
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "simatic wincc",
"version": "7.3"
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "simatic wincc",
"version": "7.4"
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "simatic wincc tia portal",
"version": null
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "simatic wincc runtime",
"version": null
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "simit",
"version": "9.0"
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "sinema remote connect",
"version": null
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "sinema server",
"version": "*"
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "softnet security client",
"version": "*"
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "telecontrol basic",
"version": "*"
}
],
"sources": [
{
"db": "IVD",
"id": "b4d8ef0b-eef6-4e09-9b80-86c9b1224d88"
},
{
"db": "CNVD",
"id": "CNVD-2016-10732"
},
{
"db": "BID",
"id": "94158"
},
{
"db": "JVNDB",
"id": "JVNDB-2016-005899"
},
{
"db": "NVD",
"id": "CVE-2016-7165"
},
{
"db": "CNNVD",
"id": "CNNVD-201611-301"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:a:siemens:security_configuration_tool:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:simit:9.0:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:sinema_server:*:sp2:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "13.0",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:simatic_net_pc_software:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "14.0",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:simatic_step_7:*:sp4:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "5.5",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:simatic_wincc:7.4:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:simatic_wincc:7.3:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:simatic_pcs_7:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "7.1",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:softnet_security_client:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "5.0",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:telecontrol_basic:*:sp2:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "3.0",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:simatic_step_7_\\(tia_portal\\):*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "14.0",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:simatic_wincc_\\(tia_portal\\):*:*:*:*:basic:*:*:*",
"cpe_name": [],
"versionEndIncluding": "14.0",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:simatic_wincc:7.2:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:simatic_wincc:7.0:sp3:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:simatic_it_production_suite:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:simatic_winac_rtx_f_2010:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:simatic_wincc_\\(tia_portal\\):*:*:*:*:advanced:*:*:*",
"cpe_name": [],
"versionEndIncluding": "14.0",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:simatic_wincc_\\(tia_portal\\):*:*:*:*:comfort:*:*:*",
"cpe_name": [],
"versionEndIncluding": "14.0",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:simatic_wincc:*:sp2:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "7.0",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:simatic_pcs7:8.2:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:primary_setup_tool:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:simatic_winac_rtx_2010:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:sinema_remote_connect:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:simatic_wincc_\\(tia_portal\\):-:*:*:*:professional:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:simatic_wincc_runtime:-:*:*:*:professional:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:simatic_pcs7:8.1:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:simatic_pcs7:8.0:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2016-7165"
}
]
},
"credits": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/credits#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "WATERSURE and KIANDRA IT",
"sources": [
{
"db": "BID",
"id": "94158"
}
],
"trust": 0.3
},
"cve": "CVE-2016-7165",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"acInsufInfo": false,
"accessComplexity": "MEDIUM",
"accessVector": "LOCAL",
"authentication": "NONE",
"author": "NVD",
"availabilityImpact": "COMPLETE",
"baseScore": 6.9,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 3.4,
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "MEDIUM",
"trust": 1.0,
"userInteractionRequired": false,
"vectorString": "AV:L/AC:M/Au:N/C:C/I:C/A:C",
"version": "2.0"
},
{
"acInsufInfo": null,
"accessComplexity": "Medium",
"accessVector": "Local",
"authentication": "None",
"author": "NVD",
"availabilityImpact": "Complete",
"baseScore": 6.9,
"confidentialityImpact": "Complete",
"exploitabilityScore": null,
"id": "CVE-2016-7165",
"impactScore": null,
"integrityImpact": "Complete",
"obtainAllPrivilege": null,
"obtainOtherPrivilege": null,
"obtainUserPrivilege": null,
"severity": "Medium",
"trust": 0.8,
"userInteractionRequired": null,
"vectorString": "AV:L/AC:M/Au:N/C:C/I:C/A:C",
"version": "2.0"
},
{
"accessComplexity": "HIGH",
"accessVector": "LOCAL",
"authentication": "MULTIPLE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 5.9,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 1.2,
"id": "CNVD-2016-10732",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "MEDIUM",
"trust": 0.6,
"vectorString": "AV:L/AC:H/Au:M/C:C/I:C/A:C",
"version": "2.0"
},
{
"accessComplexity": "HIGH",
"accessVector": "LOCAL",
"authentication": "MULTIPLE",
"author": "IVD",
"availabilityImpact": "COMPLETE",
"baseScore": 5.9,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 1.2,
"id": "b4d8ef0b-eef6-4e09-9b80-86c9b1224d88",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "MEDIUM",
"trust": 0.2,
"vectorString": "AV:L/AC:H/Au:M/C:C/I:C/A:C",
"version": "2.9 [IVD]"
},
{
"accessComplexity": "MEDIUM",
"accessVector": "LOCAL",
"authentication": "NONE",
"author": "VULHUB",
"availabilityImpact": "COMPLETE",
"baseScore": 6.9,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 3.4,
"id": "VHN-95985",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "MEDIUM",
"trust": 0.1,
"vectorString": "AV:L/AC:M/AU:N/C:C/I:C/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "HIGH",
"attackVector": "LOCAL",
"author": "NVD",
"availabilityImpact": "HIGH",
"baseScore": 6.4,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 0.5,
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:L/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
},
{
"attackComplexity": "High",
"attackVector": "Local",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 6.4,
"baseSeverity": "Medium",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "CVE-2016-7165",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "High",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:L/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2016-7165",
"trust": 1.8,
"value": "MEDIUM"
},
{
"author": "CNVD",
"id": "CNVD-2016-10732",
"trust": 0.6,
"value": "MEDIUM"
},
{
"author": "CNNVD",
"id": "CNNVD-201611-301",
"trust": 0.6,
"value": "MEDIUM"
},
{
"author": "IVD",
"id": "b4d8ef0b-eef6-4e09-9b80-86c9b1224d88",
"trust": 0.2,
"value": "MEDIUM"
},
{
"author": "VULHUB",
"id": "VHN-95985",
"trust": 0.1,
"value": "MEDIUM"
}
]
}
],
"sources": [
{
"db": "IVD",
"id": "b4d8ef0b-eef6-4e09-9b80-86c9b1224d88"
},
{
"db": "CNVD",
"id": "CNVD-2016-10732"
},
{
"db": "VULHUB",
"id": "VHN-95985"
},
{
"db": "JVNDB",
"id": "JVNDB-2016-005899"
},
{
"db": "NVD",
"id": "CVE-2016-7165"
},
{
"db": "CNNVD",
"id": "CNNVD-201611-301"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "A vulnerability has been identified in Primary Setup Tool (PST) (All versions \u003c V4.2 HF1), SIMATIC IT Production Suite (All versions \u003c V7.0 SP1 HFX 2), SIMATIC NET PC-Software (All versions \u003c V14), SIMATIC PCS 7 V7.1 (All versions), SIMATIC PCS 7 V8.0 (All versions), SIMATIC PCS 7 V8.1 (All versions), SIMATIC PCS 7 V8.2 (All versions \u003c V8.2 SP1), SIMATIC STEP 7 (TIA Portal) V13 (All versions \u003c V13 SP2), SIMATIC STEP 7 V5.X (All versions \u003c V5.5 SP4 HF11), SIMATIC WinCC (TIA Portal) Basic, Comfort, Advanced (All versions \u003c V14), SIMATIC WinCC (TIA Portal) Professional V13 (All versions \u003c V13 SP2), SIMATIC WinCC (TIA Portal) Professional V14 (All versions \u003c V14 SP1), SIMATIC WinCC Runtime Professional V13 (All versions \u003c V13 SP2), SIMATIC WinCC Runtime Professional V14 (All versions \u003c V14 SP1), SIMATIC WinCC V7.0 SP2 and earlier versions (All versions \u003c V7.0 SP2 Upd 12), SIMATIC WinCC V7.0 SP3 (All versions \u003c V7.0 SP3 Upd 8), SIMATIC WinCC V7.2 (All versions \u003c V7.2 Upd 14), SIMATIC WinCC V7.3 (All versions \u003c V7.3 Upd 11), SIMATIC WinCC V7.4 (All versions \u003c V7.4 SP1), SIMIT V9.0 (All versions \u003c V9.0 SP1), SINEMA Remote Connect Client (All versions \u003c V1.0 SP3), SINEMA Server (All versions \u003c V13 SP2), SOFTNET Security Client V5.0 (All versions), Security Configuration Tool (SCT) (All versions \u003c V4.3 HF1), TeleControl Server Basic (All versions \u003c V3.0 SP2), WinAC RTX 2010 SP2 (All versions), WinAC RTX F 2010 SP2 (All versions). Unquoted service paths could allow local Microsoft Windows operating system users to escalate their privileges if the affected products are not installed under their default path (\"C:\\Program Files\\*\" or the localized equivalent). plural Siemens The product has an installation %PROGRAMFILES% If not using a directory, it is not enclosed in quotes Windows There are vulnerabilities whose privileges are obtained by the search path. Supplementary information : CWE Vulnerability type by CWE-254: Security Features ( Security function ) ,and CWE-284: Improper Access Control ( Inappropriate access control ) Has been identified. https://cwe.mitre.org/data/definitions/254.html https://cwe.mitre.org/data/definitions/284.htmlA local user may be able to gain privileges through the Trojan executable. Founded in 1847, Siemens AG of Germany focuses on the fields of electrification, automation and digitization. Siemens is a leader in offshore wind turbine construction, gas turbine and steam turbine power generation, transmission solutions, infrastructure solutions, industrial automation, drive and software solutions, and medical imaging equipment and laboratory diagnostics. There are privilege escalation vulnerabilities in many Siemens products. Siemens SIMATIC WinCC, etc. Siemens SIMATIC WinCC is an automated data acquisition and monitoring (SCADA) system; SIMATIC PCS 7 is a distributed process control system using WinCC",
"sources": [
{
"db": "NVD",
"id": "CVE-2016-7165"
},
{
"db": "JVNDB",
"id": "JVNDB-2016-005899"
},
{
"db": "CNVD",
"id": "CNVD-2016-10732"
},
{
"db": "BID",
"id": "94158"
},
{
"db": "IVD",
"id": "b4d8ef0b-eef6-4e09-9b80-86c9b1224d88"
},
{
"db": "VULHUB",
"id": "VHN-95985"
}
],
"trust": 2.7
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2016-7165",
"trust": 3.6
},
{
"db": "ICS CERT",
"id": "ICSA-16-313-02",
"trust": 2.8
},
{
"db": "SIEMENS",
"id": "SSA-701708",
"trust": 1.7
},
{
"db": "BID",
"id": "94158",
"trust": 1.4
},
{
"db": "CNNVD",
"id": "CNNVD-201611-301",
"trust": 0.9
},
{
"db": "CNVD",
"id": "CNVD-2016-10732",
"trust": 0.8
},
{
"db": "JVNDB",
"id": "JVNDB-2016-005899",
"trust": 0.8
},
{
"db": "IVD",
"id": "B4D8EF0B-EEF6-4E09-9B80-86C9B1224D88",
"trust": 0.2
},
{
"db": "VULHUB",
"id": "VHN-95985",
"trust": 0.1
}
],
"sources": [
{
"db": "IVD",
"id": "b4d8ef0b-eef6-4e09-9b80-86c9b1224d88"
},
{
"db": "CNVD",
"id": "CNVD-2016-10732"
},
{
"db": "VULHUB",
"id": "VHN-95985"
},
{
"db": "BID",
"id": "94158"
},
{
"db": "JVNDB",
"id": "JVNDB-2016-005899"
},
{
"db": "NVD",
"id": "CVE-2016-7165"
},
{
"db": "CNNVD",
"id": "CNNVD-201611-301"
}
]
},
"id": "VAR-201611-0180",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "IVD",
"id": "b4d8ef0b-eef6-4e09-9b80-86c9b1224d88"
},
{
"db": "CNVD",
"id": "CNVD-2016-10732"
},
{
"db": "VULHUB",
"id": "VHN-95985"
}
],
"trust": 1.5737990596153848
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"ICS"
],
"sub_category": null,
"trust": 0.8
}
],
"sources": [
{
"db": "IVD",
"id": "b4d8ef0b-eef6-4e09-9b80-86c9b1224d88"
},
{
"db": "CNVD",
"id": "CNVD-2016-10732"
}
]
},
"last_update_date": "2023-12-18T13:09:01.043000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "SSA-701708",
"trust": 0.8,
"url": "http://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-701708.pdf"
},
{
"title": "Patch for a number of Siemens products with privilege escalation vulnerability (CNVD-2016-10732)",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchinfo/show/83616"
},
{
"title": "Multiple Siemens Product non-reference Windows Search path vulnerability fixes",
"trust": 0.6,
"url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=65670"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2016-10732"
},
{
"db": "JVNDB",
"id": "JVNDB-2016-005899"
},
{
"db": "CNNVD",
"id": "CNNVD-201611-301"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-254",
"trust": 1.1
},
{
"problemtype": "CWE-284",
"trust": 1.1
},
{
"problemtype": "CWE-Other",
"trust": 0.8
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-95985"
},
{
"db": "JVNDB",
"id": "JVNDB-2016-005899"
},
{
"db": "NVD",
"id": "CVE-2016-7165"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.2,
"url": "https://ics-cert.us-cert.gov/advisories/icsa-16-313-02"
},
{
"trust": 1.1,
"url": "http://www.securityfocus.com/bid/94158"
},
{
"trust": 1.1,
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-701708.pdf"
},
{
"trust": 1.1,
"url": "http://securityaffairs.co/wordpress/53266/security/cve-2016-7165-siemens.html"
},
{
"trust": 0.8,
"url": "http://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2016-7165"
},
{
"trust": 0.8,
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnid=cve-2016-7165"
},
{
"trust": 0.6,
"url": "http://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-701708.pdf"
},
{
"trust": 0.6,
"url": "https://www.us-cert.gov/ics/advisories/icsa-16-313-02"
},
{
"trust": 0.3,
"url": "http://subscriber.communications.siemens.com/"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2016-10732"
},
{
"db": "VULHUB",
"id": "VHN-95985"
},
{
"db": "BID",
"id": "94158"
},
{
"db": "JVNDB",
"id": "JVNDB-2016-005899"
},
{
"db": "NVD",
"id": "CVE-2016-7165"
},
{
"db": "CNNVD",
"id": "CNNVD-201611-301"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "IVD",
"id": "b4d8ef0b-eef6-4e09-9b80-86c9b1224d88"
},
{
"db": "CNVD",
"id": "CNVD-2016-10732"
},
{
"db": "VULHUB",
"id": "VHN-95985"
},
{
"db": "BID",
"id": "94158"
},
{
"db": "JVNDB",
"id": "JVNDB-2016-005899"
},
{
"db": "NVD",
"id": "CVE-2016-7165"
},
{
"db": "CNNVD",
"id": "CNNVD-201611-301"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2016-11-08T00:00:00",
"db": "IVD",
"id": "b4d8ef0b-eef6-4e09-9b80-86c9b1224d88"
},
{
"date": "2016-11-08T00:00:00",
"db": "CNVD",
"id": "CNVD-2016-10732"
},
{
"date": "2016-11-15T00:00:00",
"db": "VULHUB",
"id": "VHN-95985"
},
{
"date": "2016-11-08T00:00:00",
"db": "BID",
"id": "94158"
},
{
"date": "2016-11-18T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2016-005899"
},
{
"date": "2016-11-15T19:30:02.797000",
"db": "NVD",
"id": "CVE-2016-7165"
},
{
"date": "2016-11-16T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201611-301"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2016-11-08T00:00:00",
"db": "CNVD",
"id": "CNVD-2016-10732"
},
{
"date": "2018-06-15T00:00:00",
"db": "VULHUB",
"id": "VHN-95985"
},
{
"date": "2016-11-24T01:08:00",
"db": "BID",
"id": "94158"
},
{
"date": "2016-12-08T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2016-005899"
},
{
"date": "2018-06-15T01:29:00.310000",
"db": "NVD",
"id": "CVE-2016-7165"
},
{
"date": "2019-10-11T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201611-301"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "local",
"sources": [
{
"db": "BID",
"id": "94158"
},
{
"db": "CNNVD",
"id": "CNNVD-201611-301"
}
],
"trust": 0.9
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "plural Siemens Vulnerability gained in products",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2016-005899"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "other",
"sources": [
{
"db": "IVD",
"id": "b4d8ef0b-eef6-4e09-9b80-86c9b1224d88"
},
{
"db": "CNNVD",
"id": "CNNVD-201611-301"
}
],
"trust": 0.8
}
}
VAR-201209-0223
Vulnerability from variot - Updated: 2023-12-18 12:58WebNavigator in Siemens WinCC 7.0 SP3 and earlier, as used in SIMATIC PCS7 and other products, stores sensitive information under the web root with insufficient access control, which allows remote attackers to read a (1) log file or (2) configuration file via a direct request. Siemens SIMATIC is an automation software in a single engineering environment. The Siemens SIMATIC WinCC WebNavigator component incorrectly handles input, allowing an attacker to read system files using a directory traversal sequence. Siemens SIMATIC WinCC is prone to information-disclosure, SQL-injection, directory-traversal, and cross-site scripting vulnerabilities because it fails to sufficiently sanitize user-supplied input. The attacker may exploit the information-disclosure issue and directory-traversal issues to gain access to sensitive information that may lead to further attacks. The attacker may exploit the SQL-injection issue to compromise the application, access or modify data, or exploit latent vulnerabilities in the underlying database. An attacker may leverage the cross-site scripting issue to execute arbitrary script code in the browser of an unsuspecting user in the context of the affected site. This may allow the attacker to steal cookie-based authentication credentials and to launch other attacks. Siemens SIMATIC WinCC 7.0 SP3 and prior versions are vulnerable. WinCC flexible is a human-machine interface used in some machine or process applications.
The application allows users to perform certain actions via HTTP requests without performing proper validity checks to verify the requests. This can be exploited to perform certain unspecified actions when a logged-in administrative user visits a specially crafted web page. ----------------------------------------------------------------------
The final version of the CSI 6.0 has been released. Find out why this is not just another Patch Management solution: http://secunia.com/blog/325/
TITLE: Siemens SIMATIC WinCC Multiple Vulnerabilities
SECUNIA ADVISORY ID: SA50568
VERIFY ADVISORY: Secunia.com http://secunia.com/advisories/50568/ Customer Area (Credentials Required) https://ca.secunia.com/?page=viewadvisory&vuln_id=50568
RELEASE DATE: 2012-09-11
DISCUSS ADVISORY: http://secunia.com/advisories/50568/#comments
AVAILABLE ON SITE AND IN CUSTOMER AREA: * Last Update * Popularity * Comments * Criticality Level * Impact * Where * Solution Status * Operating System / Software * CVE Reference(s)
http://secunia.com/advisories/50568/
ONLY AVAILABLE IN CUSTOMER AREA: * Authentication Level * Report Reliability * Secunia PoC * Secunia Analysis * Systems Affected * Approve Distribution * Remediation Status * Secunia CVSS Score * CVSS
https://ca.secunia.com/?page=viewadvisory&vuln_id=50568
ONLY AVAILABLE WITH SECUNIA CSI AND SECUNIA PSI: * AUTOMATED SCANNING
http://secunia.com/vulnerability_scanning/personal/ http://secunia.com/vulnerability_scanning/corporate/wsus_sccm_3rd_third_party_patching/
DESCRIPTION: Multiple vulnerabilities have been reported in Siemens SIMATIC WinCC, which can be exploited by malicious people to conduct cross-site scripting attacks, conduct SQL injection attacks, and disclose certain sensitive information.
1) Certain unspecified input passed to the WebNavigator component is not properly sanitised before being returned to the user.
3) Certain input passed via SOAP messages to the WebNavigator component is not properly sanitised before being used in SQL queries. This can be exploited to manipulate SQL queries by injecting arbitrary SQL code.
4) An error within the ActiveX control can be exploited to disclose the username and password of an authenticated user.
SOLUTION: Apply Update 3.
Further details available in Customer Area: http://secunia.com/vulnerability_intelligence/
PROVIDED AND/OR DISCOVERED BY: The vendor credits Denis Baranov, Sergey Bobrov, Artem Chaykin, Vladimir Kochetkov, Pavel Toporkov, and Timur Yunusov, Positive Technologies.
ORIGINAL ADVISORY: http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-864051.pdf
OTHER REFERENCES: Further details available in Customer Area: http://secunia.com/vulnerability_intelligence/
DEEP LINKS: Further details available in Customer Area: http://secunia.com/vulnerability_intelligence/
EXTENDED DESCRIPTION: Further details available in Customer Area: http://secunia.com/vulnerability_intelligence/
EXTENDED SOLUTION: Further details available in Customer Area: http://secunia.com/vulnerability_intelligence/
EXPLOIT: Further details available in Customer Area: http://secunia.com/vulnerability_intelligence/
About: This Advisory was delivered by Secunia as a free service to help private users keeping their systems up to date against the latest vulnerabilities.
Subscribe: http://secunia.com/advisories/secunia_security_advisories/
Definitions: (Criticality, Where etc.) http://secunia.com/advisories/about_secunia_advisories/
Please Note: Secunia recommends that you verify all advisories you receive by clicking the link. Secunia NEVER sends attached files with advisories. Secunia does not advise people to install third party patches, only use those supplied by the vendor.
Unsubscribe: Secunia Security Advisories http://secunia.com/sec_adv_unsubscribe/?email=packet%40packetstormsecurity.org
Show details on source website
{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-201209-0223",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "wincc",
"scope": "eq",
"trust": 1.6,
"vendor": "siemens",
"version": "7.0"
},
{
"model": "wincc",
"scope": "eq",
"trust": 1.6,
"vendor": "siemens",
"version": "5.0"
},
{
"model": "wincc",
"scope": "eq",
"trust": 1.6,
"vendor": "siemens",
"version": "6.0"
},
{
"model": "simatic pcs7",
"scope": "eq",
"trust": 1.6,
"vendor": "siemens",
"version": "8.0"
},
{
"model": "wincc",
"scope": "lte",
"trust": 1.0,
"vendor": "siemens",
"version": "7.0"
},
{
"model": null,
"scope": "eq",
"trust": 0.8,
"vendor": "wincc",
"version": "6.0"
},
{
"model": "simatic pcs 7",
"scope": null,
"trust": 0.8,
"vendor": "siemens",
"version": null
},
{
"model": "simatic wincc",
"scope": "lte",
"trust": 0.8,
"vendor": "siemens",
"version": "7.0 sp3"
},
{
"model": null,
"scope": "eq",
"trust": 0.6,
"vendor": "wincc",
"version": "7.0"
},
{
"model": "simatic wincc",
"scope": "eq",
"trust": 0.6,
"vendor": "siemens",
"version": "7.x"
},
{
"model": "simatic pcs",
"scope": "eq",
"trust": 0.6,
"vendor": "siemens",
"version": "77.x"
},
{
"model": null,
"scope": "eq",
"trust": 0.4,
"vendor": "wincc",
"version": "5.0"
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "simatic pcs7",
"version": "8.0"
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "wincc",
"version": "*"
}
],
"sources": [
{
"db": "IVD",
"id": "5dd6af86-2353-11e6-abef-000c29c66e3d"
},
{
"db": "CNVD",
"id": "CNVD-2012-5083"
},
{
"db": "JVNDB",
"id": "JVNDB-2012-004447"
},
{
"db": "NVD",
"id": "CVE-2012-3030"
},
{
"db": "CNNVD",
"id": "CNNVD-201209-293"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:a:siemens:wincc:6.0:sp4:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:wincc:6.0:sp3:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:simatic_pcs7:8.0:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:wincc:6.0:sp2:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:wincc:*:sp3:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "7.0",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:wincc:7.0:sp2:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:wincc:7.0:sp1:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:wincc:7.0:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:wincc:6.0:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:wincc:5.0:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:wincc:5.0:sp1:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2012-3030"
}
]
},
"credits": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/credits#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Denis Baranov Sergey Bobrov, Artem Chaykin, Vladimir Kochetkov, Pavel Toporkov,Timur Yunusov from Positive Technologies",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201209-293"
}
],
"trust": 0.6
},
"cve": "CVE-2012-3030",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"acInsufInfo": false,
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "NVD",
"availabilityImpact": "NONE",
"baseScore": 5.0,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 10.0,
"impactScore": 2.9,
"integrityImpact": "NONE",
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "MEDIUM",
"trust": 1.0,
"userInteractionRequired": false,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
"version": "2.0"
},
{
"acInsufInfo": null,
"accessComplexity": "Low",
"accessVector": "Network",
"authentication": "None",
"author": "NVD",
"availabilityImpact": "None",
"baseScore": 5.0,
"confidentialityImpact": "Partial",
"exploitabilityScore": null,
"id": "CVE-2012-3030",
"impactScore": null,
"integrityImpact": "None",
"obtainAllPrivilege": null,
"obtainOtherPrivilege": null,
"obtainUserPrivilege": null,
"severity": "Medium",
"trust": 0.8,
"userInteractionRequired": null,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "IVD",
"availabilityImpact": "NONE",
"baseScore": 5.0,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 10.0,
"id": "5dd6af86-2353-11e6-abef-000c29c66e3d",
"impactScore": 2.9,
"integrityImpact": "NONE",
"severity": "MEDIUM",
"trust": 0.2,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
"version": "2.9 [IVD]"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "VULHUB",
"availabilityImpact": "NONE",
"baseScore": 5.0,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 10.0,
"id": "VHN-56311",
"impactScore": 2.9,
"integrityImpact": "NONE",
"severity": "MEDIUM",
"trust": 0.1,
"vectorString": "AV:N/AC:L/AU:N/C:P/I:N/A:N",
"version": "2.0"
}
],
"cvssV3": [],
"severity": [
{
"author": "NVD",
"id": "CVE-2012-3030",
"trust": 1.8,
"value": "MEDIUM"
},
{
"author": "CNNVD",
"id": "CNNVD-201209-293",
"trust": 0.6,
"value": "MEDIUM"
},
{
"author": "IVD",
"id": "5dd6af86-2353-11e6-abef-000c29c66e3d",
"trust": 0.2,
"value": "MEDIUM"
},
{
"author": "VULHUB",
"id": "VHN-56311",
"trust": 0.1,
"value": "MEDIUM"
}
]
}
],
"sources": [
{
"db": "IVD",
"id": "5dd6af86-2353-11e6-abef-000c29c66e3d"
},
{
"db": "VULHUB",
"id": "VHN-56311"
},
{
"db": "JVNDB",
"id": "JVNDB-2012-004447"
},
{
"db": "NVD",
"id": "CVE-2012-3030"
},
{
"db": "CNNVD",
"id": "CNNVD-201209-293"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "WebNavigator in Siemens WinCC 7.0 SP3 and earlier, as used in SIMATIC PCS7 and other products, stores sensitive information under the web root with insufficient access control, which allows remote attackers to read a (1) log file or (2) configuration file via a direct request. Siemens SIMATIC is an automation software in a single engineering environment. The Siemens SIMATIC WinCC WebNavigator component incorrectly handles input, allowing an attacker to read system files using a directory traversal sequence. Siemens SIMATIC WinCC is prone to information-disclosure, SQL-injection, directory-traversal, and cross-site scripting vulnerabilities because it fails to sufficiently sanitize user-supplied input. \nThe attacker may exploit the information-disclosure issue and directory-traversal issues to gain access to sensitive information that may lead to further attacks. \nThe attacker may exploit the SQL-injection issue to compromise the application, access or modify data, or exploit latent vulnerabilities in the underlying database. \nAn attacker may leverage the cross-site scripting issue to execute arbitrary script code in the browser of an unsuspecting user in the context of the affected site. This may allow the attacker to steal cookie-based authentication credentials and to launch other attacks. \nSiemens SIMATIC WinCC 7.0 SP3 and prior versions are vulnerable. WinCC flexible is a human-machine interface used in some machine or process applications. \n\nThe application allows users to perform certain actions via HTTP\nrequests without performing proper validity checks to verify the\nrequests. This can be exploited to perform certain unspecified\nactions when a logged-in administrative user visits a specially\ncrafted web page. ----------------------------------------------------------------------\n\nThe final version of the CSI 6.0 has been released. \nFind out why this is not just another Patch Management solution: http://secunia.com/blog/325/\n\n----------------------------------------------------------------------\n\nTITLE:\nSiemens SIMATIC WinCC Multiple Vulnerabilities\n\nSECUNIA ADVISORY ID:\nSA50568\n\nVERIFY ADVISORY:\nSecunia.com\nhttp://secunia.com/advisories/50568/\nCustomer Area (Credentials Required)\nhttps://ca.secunia.com/?page=viewadvisory\u0026vuln_id=50568\n\nRELEASE DATE:\n2012-09-11\n\nDISCUSS ADVISORY:\nhttp://secunia.com/advisories/50568/#comments\n\nAVAILABLE ON SITE AND IN CUSTOMER AREA:\n * Last Update\n * Popularity\n * Comments\n * Criticality Level\n * Impact\n * Where\n * Solution Status\n * Operating System / Software\n * CVE Reference(s)\n\nhttp://secunia.com/advisories/50568/\n\nONLY AVAILABLE IN CUSTOMER AREA:\n * Authentication Level\n * Report Reliability\n * Secunia PoC\n * Secunia Analysis\n * Systems Affected\n * Approve Distribution\n * Remediation Status\n * Secunia CVSS Score\n * CVSS\n\nhttps://ca.secunia.com/?page=viewadvisory\u0026vuln_id=50568\n\nONLY AVAILABLE WITH SECUNIA CSI AND SECUNIA PSI:\n * AUTOMATED SCANNING\n\nhttp://secunia.com/vulnerability_scanning/personal/\nhttp://secunia.com/vulnerability_scanning/corporate/wsus_sccm_3rd_third_party_patching/\n\nDESCRIPTION:\nMultiple vulnerabilities have been reported in Siemens SIMATIC WinCC,\nwhich can be exploited by malicious people to conduct cross-site\nscripting attacks, conduct SQL injection attacks, and disclose\ncertain sensitive information. \n\n1) Certain unspecified input passed to the WebNavigator component is\nnot properly sanitised before being returned to the user. \n\n3) Certain input passed via SOAP messages to the WebNavigator\ncomponent is not properly sanitised before being used in SQL queries. \nThis can be exploited to manipulate SQL queries by injecting arbitrary\nSQL code. \n\n4) An error within the ActiveX control can be exploited to disclose\nthe username and password of an authenticated user. \n\nSOLUTION:\nApply Update 3. \n\nFurther details available in Customer Area:\nhttp://secunia.com/vulnerability_intelligence/\n\nPROVIDED AND/OR DISCOVERED BY:\nThe vendor credits Denis Baranov, Sergey Bobrov, Artem Chaykin,\nVladimir Kochetkov, Pavel Toporkov, and Timur Yunusov, Positive\nTechnologies. \n\nORIGINAL ADVISORY:\nhttp://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-864051.pdf\n\nOTHER REFERENCES:\nFurther details available in Customer Area:\nhttp://secunia.com/vulnerability_intelligence/\n\nDEEP LINKS:\nFurther details available in Customer Area:\nhttp://secunia.com/vulnerability_intelligence/\n\nEXTENDED DESCRIPTION:\nFurther details available in Customer Area:\nhttp://secunia.com/vulnerability_intelligence/\n\nEXTENDED SOLUTION:\nFurther details available in Customer Area:\nhttp://secunia.com/vulnerability_intelligence/\n\nEXPLOIT:\nFurther details available in Customer Area:\nhttp://secunia.com/vulnerability_intelligence/\n\n----------------------------------------------------------------------\n\nAbout:\nThis Advisory was delivered by Secunia as a free service to help\nprivate users keeping their systems up to date against the latest\nvulnerabilities. \n\nSubscribe:\nhttp://secunia.com/advisories/secunia_security_advisories/\n\nDefinitions: (Criticality, Where etc.)\nhttp://secunia.com/advisories/about_secunia_advisories/\n\n\nPlease Note:\nSecunia recommends that you verify all advisories you receive by\nclicking the link. \nSecunia NEVER sends attached files with advisories. \nSecunia does not advise people to install third party patches, only\nuse those supplied by the vendor. \n\n----------------------------------------------------------------------\n\nUnsubscribe: Secunia Security Advisories\nhttp://secunia.com/sec_adv_unsubscribe/?email=packet%40packetstormsecurity.org\n\n----------------------------------------------------------------------\n\n\n",
"sources": [
{
"db": "NVD",
"id": "CVE-2012-3030"
},
{
"db": "JVNDB",
"id": "JVNDB-2012-004447"
},
{
"db": "CNVD",
"id": "CNVD-2012-5083"
},
{
"db": "BID",
"id": "55492"
},
{
"db": "IVD",
"id": "5dd6af86-2353-11e6-abef-000c29c66e3d"
},
{
"db": "VULHUB",
"id": "VHN-56311"
},
{
"db": "PACKETSTORM",
"id": "116445"
},
{
"db": "PACKETSTORM",
"id": "116447"
}
],
"trust": 2.88
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2012-3030",
"trust": 3.6
},
{
"db": "SIEMENS",
"id": "SSA-864051",
"trust": 2.5
},
{
"db": "ICS CERT",
"id": "ICSA-12-256-01",
"trust": 2.5
},
{
"db": "CNNVD",
"id": "CNNVD-201209-293",
"trust": 0.9
},
{
"db": "BID",
"id": "55492",
"trust": 0.9
},
{
"db": "CNVD",
"id": "CNVD-2012-5083",
"trust": 0.8
},
{
"db": "JVNDB",
"id": "JVNDB-2012-004447",
"trust": 0.8
},
{
"db": "SECUNIA",
"id": "50568",
"trust": 0.8
},
{
"db": "NSFOCUS",
"id": "20651",
"trust": 0.6
},
{
"db": "NSFOCUS",
"id": "20932",
"trust": 0.6
},
{
"db": "IVD",
"id": "5DD6AF86-2353-11E6-ABEF-000C29C66E3D",
"trust": 0.2
},
{
"db": "SECUNIA",
"id": "50581",
"trust": 0.2
},
{
"db": "VULHUB",
"id": "VHN-56311",
"trust": 0.1
},
{
"db": "PACKETSTORM",
"id": "116445",
"trust": 0.1
},
{
"db": "PACKETSTORM",
"id": "116447",
"trust": 0.1
}
],
"sources": [
{
"db": "IVD",
"id": "5dd6af86-2353-11e6-abef-000c29c66e3d"
},
{
"db": "CNVD",
"id": "CNVD-2012-5083"
},
{
"db": "VULHUB",
"id": "VHN-56311"
},
{
"db": "BID",
"id": "55492"
},
{
"db": "JVNDB",
"id": "JVNDB-2012-004447"
},
{
"db": "PACKETSTORM",
"id": "116445"
},
{
"db": "PACKETSTORM",
"id": "116447"
},
{
"db": "NVD",
"id": "CVE-2012-3030"
},
{
"db": "CNNVD",
"id": "CNNVD-201209-293"
}
]
},
"id": "VAR-201209-0223",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "IVD",
"id": "5dd6af86-2353-11e6-abef-000c29c66e3d"
},
{
"db": "CNVD",
"id": "CNVD-2012-5083"
},
{
"db": "VULHUB",
"id": "VHN-56311"
}
],
"trust": 1.49052891
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"ICS"
],
"sub_category": null,
"trust": 0.8
}
],
"sources": [
{
"db": "IVD",
"id": "5dd6af86-2353-11e6-abef-000c29c66e3d"
},
{
"db": "CNVD",
"id": "CNVD-2012-5083"
}
]
},
"last_update_date": "2023-12-18T12:58:16.139000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Top Page",
"trust": 0.8,
"url": "http://www.siemens.com/"
},
{
"title": "SSA-864051: Multiple Vulnerabilities in WinCC 7.0 SP3",
"trust": 0.8,
"url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-864051.pdf"
},
{
"title": "\u30b7\u30fc\u30e1\u30f3\u30b9\u30bd\u30ea\u30e5\u30fc\u30b7\u30e7\u30f3\u30d1\u30fc\u30c8\u30ca\u30fc",
"trust": 0.8,
"url": "http://www.automation.siemens.com/automation/jp/ja/solutionpartner/pages/default.aspx"
},
{
"title": "\u30b7\u30fc\u30e1\u30f3\u30b9\u30fb\u30b8\u30e3\u30d1\u30f3\u682a\u5f0f\u4f1a\u793e",
"trust": 0.8,
"url": "http://www.siemens.com/entry/jp/ja/"
},
{
"title": "Patch for Siemens SIMATIC WinCC arbitrary file read vulnerability",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchinfo/show/22131"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2012-5083"
},
{
"db": "JVNDB",
"id": "JVNDB-2012-004447"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-264",
"trust": 1.9
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-56311"
},
{
"db": "JVNDB",
"id": "JVNDB-2012-004447"
},
{
"db": "NVD",
"id": "CVE-2012-3030"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.5,
"url": "http://www.us-cert.gov/control_systems/pdf/icsa-12-256-01.pdf"
},
{
"trust": 1.9,
"url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-864051.pdf"
},
{
"trust": 1.7,
"url": "http://en.securitylab.ru/lab/pt-2012-43"
},
{
"trust": 0.8,
"url": "http://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2012-3030"
},
{
"trust": 0.8,
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnid=cve-2012-3030"
},
{
"trust": 0.6,
"url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-864051.pdfhttp"
},
{
"trust": 0.6,
"url": "http://secunia.com/advisories/50568"
},
{
"trust": 0.6,
"url": "http://www.securityfocus.com/bid/55492"
},
{
"trust": 0.6,
"url": "http://www.nsfocus.net/vulndb/20932"
},
{
"trust": 0.6,
"url": "http://www.nsfocus.net/vulndb/20651"
},
{
"trust": 0.3,
"url": "http://aunz.siemens.com/newscentre/productreleases/pages/iac_pr_simaticwinccv62.aspx"
},
{
"trust": 0.2,
"url": "http://secunia.com/vulnerability_intelligence/"
},
{
"trust": 0.2,
"url": "http://secunia.com/advisories/secunia_security_advisories/"
},
{
"trust": 0.2,
"url": "http://secunia.com/vulnerability_scanning/corporate/wsus_sccm_3rd_third_party_patching/"
},
{
"trust": 0.2,
"url": "http://secunia.com/vulnerability_scanning/personal/"
},
{
"trust": 0.2,
"url": "http://secunia.com/sec_adv_unsubscribe/?email=packet%40packetstormsecurity.org"
},
{
"trust": 0.2,
"url": "http://secunia.com/blog/325/"
},
{
"trust": 0.2,
"url": "http://secunia.com/advisories/about_secunia_advisories/"
},
{
"trust": 0.1,
"url": "https://ca.secunia.com/?page=viewadvisory\u0026vuln_id=50581"
},
{
"trust": 0.1,
"url": "http://secunia.com/advisories/50581/#comments"
},
{
"trust": 0.1,
"url": "http://secunia.com/advisories/50581/"
},
{
"trust": 0.1,
"url": "http://secunia.com/advisories/50568/"
},
{
"trust": 0.1,
"url": "http://secunia.com/advisories/50568/#comments"
},
{
"trust": 0.1,
"url": "https://ca.secunia.com/?page=viewadvisory\u0026vuln_id=50568"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2012-5083"
},
{
"db": "VULHUB",
"id": "VHN-56311"
},
{
"db": "BID",
"id": "55492"
},
{
"db": "JVNDB",
"id": "JVNDB-2012-004447"
},
{
"db": "PACKETSTORM",
"id": "116445"
},
{
"db": "PACKETSTORM",
"id": "116447"
},
{
"db": "NVD",
"id": "CVE-2012-3030"
},
{
"db": "CNNVD",
"id": "CNNVD-201209-293"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "IVD",
"id": "5dd6af86-2353-11e6-abef-000c29c66e3d"
},
{
"db": "CNVD",
"id": "CNVD-2012-5083"
},
{
"db": "VULHUB",
"id": "VHN-56311"
},
{
"db": "BID",
"id": "55492"
},
{
"db": "JVNDB",
"id": "JVNDB-2012-004447"
},
{
"db": "PACKETSTORM",
"id": "116445"
},
{
"db": "PACKETSTORM",
"id": "116447"
},
{
"db": "NVD",
"id": "CVE-2012-3030"
},
{
"db": "CNNVD",
"id": "CNNVD-201209-293"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2012-09-13T00:00:00",
"db": "IVD",
"id": "5dd6af86-2353-11e6-abef-000c29c66e3d"
},
{
"date": "2012-09-13T00:00:00",
"db": "CNVD",
"id": "CNVD-2012-5083"
},
{
"date": "2012-09-18T00:00:00",
"db": "VULHUB",
"id": "VHN-56311"
},
{
"date": "2012-09-11T00:00:00",
"db": "BID",
"id": "55492"
},
{
"date": "2012-09-20T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2012-004447"
},
{
"date": "2012-09-11T07:30:00",
"db": "PACKETSTORM",
"id": "116445"
},
{
"date": "2012-09-11T07:30:06",
"db": "PACKETSTORM",
"id": "116447"
},
{
"date": "2012-09-18T14:55:01.443000",
"db": "NVD",
"id": "CVE-2012-3030"
},
{
"date": "2012-09-18T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201209-293"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2012-09-13T00:00:00",
"db": "CNVD",
"id": "CNVD-2012-5083"
},
{
"date": "2012-12-20T00:00:00",
"db": "VULHUB",
"id": "VHN-56311"
},
{
"date": "2012-09-12T22:50:00",
"db": "BID",
"id": "55492"
},
{
"date": "2012-09-20T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2012-004447"
},
{
"date": "2012-12-20T05:00:00",
"db": "NVD",
"id": "CVE-2012-3030"
},
{
"date": "2012-09-20T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201209-293"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201209-293"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Siemens SIMATIC WinCC Arbitrary File Read Vulnerability",
"sources": [
{
"db": "IVD",
"id": "5dd6af86-2353-11e6-abef-000c29c66e3d"
},
{
"db": "CNVD",
"id": "CNVD-2012-5083"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "permissions and access control",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201209-293"
}
],
"trust": 0.6
}
}
VAR-201209-0222
Vulnerability from variot - Updated: 2023-12-18 12:58Cross-site request forgery (CSRF) vulnerability in WebNavigator in Siemens WinCC 7.0 SP3 and earlier, as used in SIMATIC PCS7 and other products, allows remote attackers to hijack the authentication of arbitrary users for requests that modify data or cause a denial of service. (DoS) There is a possibility of being put into a state. Siemens SIMATIC is an automation software in a single engineering environment. Siemens SIMATIC WinCC is prone to a cross-site request-forgery vulnerability. Exploiting this issue may allow a remote attacker to perform certain administrative actions and gain unauthorized access to the affected application; other attacks are also possible. Siemens SIMATIC WinCC 7.0 SP3 and prior versions are vulnerable.
The application allows users to perform certain actions via HTTP requests without performing proper validity checks to verify the requests. This can be exploited to perform certain unspecified actions when a logged-in administrative user visits a specially crafted web page. ----------------------------------------------------------------------
The final version of the CSI 6.0 has been released. Find out why this is not just another Patch Management solution: http://secunia.com/blog/325/
TITLE: Siemens SIMATIC WinCC Multiple Vulnerabilities
SECUNIA ADVISORY ID: SA50568
VERIFY ADVISORY: Secunia.com http://secunia.com/advisories/50568/ Customer Area (Credentials Required) https://ca.secunia.com/?page=viewadvisory&vuln_id=50568
RELEASE DATE: 2012-09-11
DISCUSS ADVISORY: http://secunia.com/advisories/50568/#comments
AVAILABLE ON SITE AND IN CUSTOMER AREA: * Last Update * Popularity * Comments * Criticality Level * Impact * Where * Solution Status * Operating System / Software * CVE Reference(s)
http://secunia.com/advisories/50568/
ONLY AVAILABLE IN CUSTOMER AREA: * Authentication Level * Report Reliability * Secunia PoC * Secunia Analysis * Systems Affected * Approve Distribution * Remediation Status * Secunia CVSS Score * CVSS
https://ca.secunia.com/?page=viewadvisory&vuln_id=50568
ONLY AVAILABLE WITH SECUNIA CSI AND SECUNIA PSI: * AUTOMATED SCANNING
http://secunia.com/vulnerability_scanning/personal/ http://secunia.com/vulnerability_scanning/corporate/wsus_sccm_3rd_third_party_patching/
DESCRIPTION: Multiple vulnerabilities have been reported in Siemens SIMATIC WinCC, which can be exploited by malicious people to conduct cross-site scripting attacks, conduct SQL injection attacks, and disclose certain sensitive information.
1) Certain unspecified input passed to the WebNavigator component is not properly sanitised before being returned to the user. This can be exploited to execute arbitrary HTML and script code in a user's browser session in context of an affected site.
2) Certain input passed to the WebNavigator component is not properly verified before being used to read files. This can be exploited to read arbitrary files via directory traversal sequences.
3) Certain input passed via SOAP messages to the WebNavigator component is not properly sanitised before being used in SQL queries. This can be exploited to manipulate SQL queries by injecting arbitrary SQL code.
4) An error within the ActiveX control can be exploited to disclose the username and password of an authenticated user.
SOLUTION: Apply Update 3.
Further details available in Customer Area: http://secunia.com/vulnerability_intelligence/
PROVIDED AND/OR DISCOVERED BY: The vendor credits Denis Baranov, Sergey Bobrov, Artem Chaykin, Vladimir Kochetkov, Pavel Toporkov, and Timur Yunusov, Positive Technologies.
ORIGINAL ADVISORY: http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-864051.pdf
OTHER REFERENCES: Further details available in Customer Area: http://secunia.com/vulnerability_intelligence/
DEEP LINKS: Further details available in Customer Area: http://secunia.com/vulnerability_intelligence/
EXTENDED DESCRIPTION: Further details available in Customer Area: http://secunia.com/vulnerability_intelligence/
EXTENDED SOLUTION: Further details available in Customer Area: http://secunia.com/vulnerability_intelligence/
EXPLOIT: Further details available in Customer Area: http://secunia.com/vulnerability_intelligence/
About: This Advisory was delivered by Secunia as a free service to help private users keeping their systems up to date against the latest vulnerabilities.
Subscribe: http://secunia.com/advisories/secunia_security_advisories/
Definitions: (Criticality, Where etc.) http://secunia.com/advisories/about_secunia_advisories/
Please Note: Secunia recommends that you verify all advisories you receive by clicking the link. Secunia NEVER sends attached files with advisories. Secunia does not advise people to install third party patches, only use those supplied by the vendor.
Unsubscribe: Secunia Security Advisories http://secunia.com/sec_adv_unsubscribe/?email=packet%40packetstormsecurity.org
Show details on source website
{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-201209-0222",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "wincc",
"scope": "eq",
"trust": 1.6,
"vendor": "siemens",
"version": "7.0"
},
{
"model": "wincc",
"scope": "eq",
"trust": 1.6,
"vendor": "siemens",
"version": "5.0"
},
{
"model": "wincc",
"scope": "eq",
"trust": 1.6,
"vendor": "siemens",
"version": "6.0"
},
{
"model": "simatic pcs7",
"scope": "eq",
"trust": 1.6,
"vendor": "siemens",
"version": "8.0"
},
{
"model": "wincc",
"scope": "lte",
"trust": 1.0,
"vendor": "siemens",
"version": "7.0"
},
{
"model": "simatic wincc",
"scope": "eq",
"trust": 0.9,
"vendor": "siemens",
"version": "6.2"
},
{
"model": null,
"scope": "eq",
"trust": 0.8,
"vendor": "wincc",
"version": "6.0"
},
{
"model": "simatic pcs 7",
"scope": null,
"trust": 0.8,
"vendor": "siemens",
"version": null
},
{
"model": "simatic wincc",
"scope": "lte",
"trust": 0.8,
"vendor": "siemens",
"version": "7.0 sp3"
},
{
"model": null,
"scope": "eq",
"trust": 0.6,
"vendor": "wincc",
"version": "7.0"
},
{
"model": null,
"scope": "eq",
"trust": 0.4,
"vendor": "wincc",
"version": "5.0"
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "simatic pcs7",
"version": "8.0"
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "wincc",
"version": "*"
}
],
"sources": [
{
"db": "IVD",
"id": "5ddc3ec4-2353-11e6-abef-000c29c66e3d"
},
{
"db": "CNVD",
"id": "CNVD-2012-5088"
},
{
"db": "BID",
"id": "55493"
},
{
"db": "JVNDB",
"id": "JVNDB-2012-004446"
},
{
"db": "NVD",
"id": "CVE-2012-3028"
},
{
"db": "CNNVD",
"id": "CNNVD-201209-303"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:a:siemens:simatic_pcs7:8.0:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:wincc:6.0:sp4:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:wincc:6.0:sp3:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:wincc:7.0:sp2:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:wincc:7.0:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:wincc:6.0:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:wincc:5.0:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:wincc:*:sp3:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "7.0",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:wincc:7.0:sp1:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:wincc:5.0:sp1:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:wincc:6.0:sp2:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2012-3028"
}
]
},
"credits": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/credits#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Denis Baranov, Sergey Bobrov, Artem Chaykin, Vladimir Kochetkov, Pavel Toporkov, and Timur Yunusov from Positive Technologies",
"sources": [
{
"db": "BID",
"id": "55493"
},
{
"db": "CNNVD",
"id": "CNNVD-201209-303"
}
],
"trust": 0.9
},
"cve": "CVE-2012-3028",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"acInsufInfo": false,
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "NVD",
"availabilityImpact": "PARTIAL",
"baseScore": 6.8,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 8.6,
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "MEDIUM",
"trust": 1.0,
"userInteractionRequired": true,
"vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
{
"acInsufInfo": null,
"accessComplexity": "Medium",
"accessVector": "Network",
"authentication": "None",
"author": "NVD",
"availabilityImpact": "Partial",
"baseScore": 6.8,
"confidentialityImpact": "Partial",
"exploitabilityScore": null,
"id": "CVE-2012-3028",
"impactScore": null,
"integrityImpact": "Partial",
"obtainAllPrivilege": null,
"obtainOtherPrivilege": null,
"obtainUserPrivilege": null,
"severity": "Medium",
"trust": 0.8,
"userInteractionRequired": null,
"vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
{
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 7.8,
"confidentialityImpact": "NONE",
"exploitabilityScore": 8.6,
"id": "CNVD-2012-5088",
"impactScore": 7.8,
"integrityImpact": "PARTIAL",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:M/Au:N/C:N/I:P/A:C",
"version": "2.0"
},
{
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "IVD",
"availabilityImpact": "COMPLETE",
"baseScore": 7.8,
"confidentialityImpact": "NONE",
"exploitabilityScore": 8.6,
"id": "5ddc3ec4-2353-11e6-abef-000c29c66e3d",
"impactScore": 7.8,
"integrityImpact": "PARTIAL",
"severity": "HIGH",
"trust": 0.2,
"vectorString": "AV:N/AC:M/Au:N/C:N/I:P/A:C",
"version": "2.9 [IVD]"
},
{
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "VULHUB",
"availabilityImpact": "PARTIAL",
"baseScore": 6.8,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 8.6,
"id": "VHN-56309",
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"severity": "MEDIUM",
"trust": 0.1,
"vectorString": "AV:N/AC:M/AU:N/C:P/I:P/A:P",
"version": "2.0"
}
],
"cvssV3": [],
"severity": [
{
"author": "NVD",
"id": "CVE-2012-3028",
"trust": 1.8,
"value": "MEDIUM"
},
{
"author": "CNVD",
"id": "CNVD-2012-5088",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "CNNVD",
"id": "CNNVD-201209-303",
"trust": 0.6,
"value": "MEDIUM"
},
{
"author": "IVD",
"id": "5ddc3ec4-2353-11e6-abef-000c29c66e3d",
"trust": 0.2,
"value": "MEDIUM"
},
{
"author": "VULHUB",
"id": "VHN-56309",
"trust": 0.1,
"value": "MEDIUM"
}
]
}
],
"sources": [
{
"db": "IVD",
"id": "5ddc3ec4-2353-11e6-abef-000c29c66e3d"
},
{
"db": "CNVD",
"id": "CNVD-2012-5088"
},
{
"db": "VULHUB",
"id": "VHN-56309"
},
{
"db": "JVNDB",
"id": "JVNDB-2012-004446"
},
{
"db": "NVD",
"id": "CVE-2012-3028"
},
{
"db": "CNNVD",
"id": "CNNVD-201209-303"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Cross-site request forgery (CSRF) vulnerability in WebNavigator in Siemens WinCC 7.0 SP3 and earlier, as used in SIMATIC PCS7 and other products, allows remote attackers to hijack the authentication of arbitrary users for requests that modify data or cause a denial of service. (DoS) There is a possibility of being put into a state. Siemens SIMATIC is an automation software in a single engineering environment. Siemens SIMATIC WinCC is prone to a cross-site request-forgery vulnerability. \nExploiting this issue may allow a remote attacker to perform certain administrative actions and gain unauthorized access to the affected application; other attacks are also possible. \nSiemens SIMATIC WinCC 7.0 SP3 and prior versions are vulnerable. \n\nThe application allows users to perform certain actions via HTTP\nrequests without performing proper validity checks to verify the\nrequests. This can be exploited to perform certain unspecified\nactions when a logged-in administrative user visits a specially\ncrafted web page. ----------------------------------------------------------------------\n\nThe final version of the CSI 6.0 has been released. \nFind out why this is not just another Patch Management solution: http://secunia.com/blog/325/\n\n----------------------------------------------------------------------\n\nTITLE:\nSiemens SIMATIC WinCC Multiple Vulnerabilities\n\nSECUNIA ADVISORY ID:\nSA50568\n\nVERIFY ADVISORY:\nSecunia.com\nhttp://secunia.com/advisories/50568/\nCustomer Area (Credentials Required)\nhttps://ca.secunia.com/?page=viewadvisory\u0026vuln_id=50568\n\nRELEASE DATE:\n2012-09-11\n\nDISCUSS ADVISORY:\nhttp://secunia.com/advisories/50568/#comments\n\nAVAILABLE ON SITE AND IN CUSTOMER AREA:\n * Last Update\n * Popularity\n * Comments\n * Criticality Level\n * Impact\n * Where\n * Solution Status\n * Operating System / Software\n * CVE Reference(s)\n\nhttp://secunia.com/advisories/50568/\n\nONLY AVAILABLE IN CUSTOMER AREA:\n * Authentication Level\n * Report Reliability\n * Secunia PoC\n * Secunia Analysis\n * Systems Affected\n * Approve Distribution\n * Remediation Status\n * Secunia CVSS Score\n * CVSS\n\nhttps://ca.secunia.com/?page=viewadvisory\u0026vuln_id=50568\n\nONLY AVAILABLE WITH SECUNIA CSI AND SECUNIA PSI:\n * AUTOMATED SCANNING\n\nhttp://secunia.com/vulnerability_scanning/personal/\nhttp://secunia.com/vulnerability_scanning/corporate/wsus_sccm_3rd_third_party_patching/\n\nDESCRIPTION:\nMultiple vulnerabilities have been reported in Siemens SIMATIC WinCC,\nwhich can be exploited by malicious people to conduct cross-site\nscripting attacks, conduct SQL injection attacks, and disclose\ncertain sensitive information. \n\n1) Certain unspecified input passed to the WebNavigator component is\nnot properly sanitised before being returned to the user. This can be\nexploited to execute arbitrary HTML and script code in a user\u0027s\nbrowser session in context of an affected site. \n\n2) Certain input passed to the WebNavigator component is not properly\nverified before being used to read files. This can be exploited to\nread arbitrary files via directory traversal sequences. \n\n3) Certain input passed via SOAP messages to the WebNavigator\ncomponent is not properly sanitised before being used in SQL queries. \nThis can be exploited to manipulate SQL queries by injecting arbitrary\nSQL code. \n\n4) An error within the ActiveX control can be exploited to disclose\nthe username and password of an authenticated user. \n\nSOLUTION:\nApply Update 3. \n\nFurther details available in Customer Area:\nhttp://secunia.com/vulnerability_intelligence/\n\nPROVIDED AND/OR DISCOVERED BY:\nThe vendor credits Denis Baranov, Sergey Bobrov, Artem Chaykin,\nVladimir Kochetkov, Pavel Toporkov, and Timur Yunusov, Positive\nTechnologies. \n\nORIGINAL ADVISORY:\nhttp://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-864051.pdf\n\nOTHER REFERENCES:\nFurther details available in Customer Area:\nhttp://secunia.com/vulnerability_intelligence/\n\nDEEP LINKS:\nFurther details available in Customer Area:\nhttp://secunia.com/vulnerability_intelligence/\n\nEXTENDED DESCRIPTION:\nFurther details available in Customer Area:\nhttp://secunia.com/vulnerability_intelligence/\n\nEXTENDED SOLUTION:\nFurther details available in Customer Area:\nhttp://secunia.com/vulnerability_intelligence/\n\nEXPLOIT:\nFurther details available in Customer Area:\nhttp://secunia.com/vulnerability_intelligence/\n\n----------------------------------------------------------------------\n\nAbout:\nThis Advisory was delivered by Secunia as a free service to help\nprivate users keeping their systems up to date against the latest\nvulnerabilities. \n\nSubscribe:\nhttp://secunia.com/advisories/secunia_security_advisories/\n\nDefinitions: (Criticality, Where etc.)\nhttp://secunia.com/advisories/about_secunia_advisories/\n\n\nPlease Note:\nSecunia recommends that you verify all advisories you receive by\nclicking the link. \nSecunia NEVER sends attached files with advisories. \nSecunia does not advise people to install third party patches, only\nuse those supplied by the vendor. \n\n----------------------------------------------------------------------\n\nUnsubscribe: Secunia Security Advisories\nhttp://secunia.com/sec_adv_unsubscribe/?email=packet%40packetstormsecurity.org\n\n----------------------------------------------------------------------\n\n\n",
"sources": [
{
"db": "NVD",
"id": "CVE-2012-3028"
},
{
"db": "JVNDB",
"id": "JVNDB-2012-004446"
},
{
"db": "CNVD",
"id": "CNVD-2012-5088"
},
{
"db": "BID",
"id": "55493"
},
{
"db": "IVD",
"id": "5ddc3ec4-2353-11e6-abef-000c29c66e3d"
},
{
"db": "VULHUB",
"id": "VHN-56309"
},
{
"db": "PACKETSTORM",
"id": "116445"
},
{
"db": "PACKETSTORM",
"id": "116447"
}
],
"trust": 2.88
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2012-3028",
"trust": 3.6
},
{
"db": "SIEMENS",
"id": "SSA-864051",
"trust": 2.8
},
{
"db": "ICS CERT",
"id": "ICSA-12-256-01",
"trust": 2.5
},
{
"db": "BID",
"id": "55493",
"trust": 1.0
},
{
"db": "CNNVD",
"id": "CNNVD-201209-303",
"trust": 0.9
},
{
"db": "CNVD",
"id": "CNVD-2012-5088",
"trust": 0.8
},
{
"db": "JVNDB",
"id": "JVNDB-2012-004446",
"trust": 0.8
},
{
"db": "SECUNIA",
"id": "50581",
"trust": 0.8
},
{
"db": "NSFOCUS",
"id": "20652",
"trust": 0.6
},
{
"db": "NSFOCUS",
"id": "20933",
"trust": 0.6
},
{
"db": "IVD",
"id": "5DDC3EC4-2353-11E6-ABEF-000C29C66E3D",
"trust": 0.2
},
{
"db": "SECUNIA",
"id": "50568",
"trust": 0.2
},
{
"db": "VULHUB",
"id": "VHN-56309",
"trust": 0.1
},
{
"db": "PACKETSTORM",
"id": "116445",
"trust": 0.1
},
{
"db": "PACKETSTORM",
"id": "116447",
"trust": 0.1
}
],
"sources": [
{
"db": "IVD",
"id": "5ddc3ec4-2353-11e6-abef-000c29c66e3d"
},
{
"db": "CNVD",
"id": "CNVD-2012-5088"
},
{
"db": "VULHUB",
"id": "VHN-56309"
},
{
"db": "BID",
"id": "55493"
},
{
"db": "JVNDB",
"id": "JVNDB-2012-004446"
},
{
"db": "PACKETSTORM",
"id": "116445"
},
{
"db": "PACKETSTORM",
"id": "116447"
},
{
"db": "NVD",
"id": "CVE-2012-3028"
},
{
"db": "CNNVD",
"id": "CNNVD-201209-303"
}
]
},
"id": "VAR-201209-0222",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "IVD",
"id": "5ddc3ec4-2353-11e6-abef-000c29c66e3d"
},
{
"db": "CNVD",
"id": "CNVD-2012-5088"
},
{
"db": "VULHUB",
"id": "VHN-56309"
}
],
"trust": 1.49052891
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"ICS"
],
"sub_category": null,
"trust": 0.8
}
],
"sources": [
{
"db": "IVD",
"id": "5ddc3ec4-2353-11e6-abef-000c29c66e3d"
},
{
"db": "CNVD",
"id": "CNVD-2012-5088"
}
]
},
"last_update_date": "2023-12-18T12:58:16.092000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Top Page",
"trust": 0.8,
"url": "http://www.siemens.com/"
},
{
"title": "SSA-864051: Multiple Vulnerabilities in WinCC 7.0 SP3",
"trust": 0.8,
"url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-864051.pdf"
},
{
"title": "\u30b7\u30fc\u30e1\u30f3\u30b9\u30bd\u30ea\u30e5\u30fc\u30b7\u30e7\u30f3\u30d1\u30fc\u30c8\u30ca\u30fc",
"trust": 0.8,
"url": "http://www.automation.siemens.com/automation/jp/ja/solutionpartner/pages/default.aspx"
},
{
"title": "\u30b7\u30fc\u30e1\u30f3\u30b9\u30fb\u30b8\u30e3\u30d1\u30f3\u682a\u5f0f\u4f1a\u793e",
"trust": 0.8,
"url": "http://www.siemens.com/entry/jp/ja/"
},
{
"title": "Patch for Siemens SIMATIC WinCC Cross-Site Request Forgery Vulnerability",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchinfo/show/80787"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2012-5088"
},
{
"db": "JVNDB",
"id": "JVNDB-2012-004446"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-352",
"trust": 1.9
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-56309"
},
{
"db": "JVNDB",
"id": "JVNDB-2012-004446"
},
{
"db": "NVD",
"id": "CVE-2012-3028"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.5,
"url": "http://www.us-cert.gov/control_systems/pdf/icsa-12-256-01.pdf"
},
{
"trust": 2.2,
"url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-864051.pdf"
},
{
"trust": 1.7,
"url": "http://en.securitylab.ru/lab/pt-2012-42"
},
{
"trust": 0.8,
"url": "http://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2012-3028"
},
{
"trust": 0.8,
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnid=cve-2012-3028"
},
{
"trust": 0.6,
"url": "http://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-864051.pdf"
},
{
"trust": 0.6,
"url": "http://secunia.com/advisories/50581"
},
{
"trust": 0.6,
"url": "http://www.securityfocus.com/bid/55493"
},
{
"trust": 0.6,
"url": "http://www.nsfocus.net/vulndb/20933"
},
{
"trust": 0.6,
"url": "http://www.nsfocus.net/vulndb/20652"
},
{
"trust": 0.3,
"url": "http://www.automation.siemens.com/mcms/human-machine-interface/en/visualization-software/scada/simatic-wincc/pages/default.aspx"
},
{
"trust": 0.2,
"url": "http://secunia.com/vulnerability_intelligence/"
},
{
"trust": 0.2,
"url": "http://secunia.com/advisories/secunia_security_advisories/"
},
{
"trust": 0.2,
"url": "http://secunia.com/vulnerability_scanning/corporate/wsus_sccm_3rd_third_party_patching/"
},
{
"trust": 0.2,
"url": "http://secunia.com/vulnerability_scanning/personal/"
},
{
"trust": 0.2,
"url": "http://secunia.com/sec_adv_unsubscribe/?email=packet%40packetstormsecurity.org"
},
{
"trust": 0.2,
"url": "http://secunia.com/blog/325/"
},
{
"trust": 0.2,
"url": "http://secunia.com/advisories/about_secunia_advisories/"
},
{
"trust": 0.1,
"url": "https://ca.secunia.com/?page=viewadvisory\u0026vuln_id=50581"
},
{
"trust": 0.1,
"url": "http://secunia.com/advisories/50581/#comments"
},
{
"trust": 0.1,
"url": "http://secunia.com/advisories/50581/"
},
{
"trust": 0.1,
"url": "http://secunia.com/advisories/50568/"
},
{
"trust": 0.1,
"url": "http://secunia.com/advisories/50568/#comments"
},
{
"trust": 0.1,
"url": "https://ca.secunia.com/?page=viewadvisory\u0026vuln_id=50568"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2012-5088"
},
{
"db": "VULHUB",
"id": "VHN-56309"
},
{
"db": "BID",
"id": "55493"
},
{
"db": "JVNDB",
"id": "JVNDB-2012-004446"
},
{
"db": "PACKETSTORM",
"id": "116445"
},
{
"db": "PACKETSTORM",
"id": "116447"
},
{
"db": "NVD",
"id": "CVE-2012-3028"
},
{
"db": "CNNVD",
"id": "CNNVD-201209-303"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "IVD",
"id": "5ddc3ec4-2353-11e6-abef-000c29c66e3d"
},
{
"db": "CNVD",
"id": "CNVD-2012-5088"
},
{
"db": "VULHUB",
"id": "VHN-56309"
},
{
"db": "BID",
"id": "55493"
},
{
"db": "JVNDB",
"id": "JVNDB-2012-004446"
},
{
"db": "PACKETSTORM",
"id": "116445"
},
{
"db": "PACKETSTORM",
"id": "116447"
},
{
"db": "NVD",
"id": "CVE-2012-3028"
},
{
"db": "CNNVD",
"id": "CNNVD-201209-303"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2012-09-13T00:00:00",
"db": "IVD",
"id": "5ddc3ec4-2353-11e6-abef-000c29c66e3d"
},
{
"date": "2012-09-13T00:00:00",
"db": "CNVD",
"id": "CNVD-2012-5088"
},
{
"date": "2012-09-18T00:00:00",
"db": "VULHUB",
"id": "VHN-56309"
},
{
"date": "2012-09-11T00:00:00",
"db": "BID",
"id": "55493"
},
{
"date": "2012-09-20T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2012-004446"
},
{
"date": "2012-09-11T07:30:00",
"db": "PACKETSTORM",
"id": "116445"
},
{
"date": "2012-09-11T07:30:06",
"db": "PACKETSTORM",
"id": "116447"
},
{
"date": "2012-09-18T14:55:01.397000",
"db": "NVD",
"id": "CVE-2012-3028"
},
{
"date": "2012-09-18T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201209-303"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2016-08-26T00:00:00",
"db": "CNVD",
"id": "CNVD-2012-5088"
},
{
"date": "2012-09-19T00:00:00",
"db": "VULHUB",
"id": "VHN-56309"
},
{
"date": "2015-03-19T09:33:00",
"db": "BID",
"id": "55493"
},
{
"date": "2012-09-20T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2012-004446"
},
{
"date": "2012-09-19T04:00:00",
"db": "NVD",
"id": "CVE-2012-3028"
},
{
"date": "2012-09-18T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201209-303"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201209-303"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Siemens SIMATIC WinCC Cross-Site Request Forgery Vulnerability",
"sources": [
{
"db": "IVD",
"id": "5ddc3ec4-2353-11e6-abef-000c29c66e3d"
},
{
"db": "CNVD",
"id": "CNVD-2012-5088"
},
{
"db": "BID",
"id": "55493"
},
{
"db": "CNNVD",
"id": "CNNVD-201209-303"
}
],
"trust": 1.7
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "cross-site request forgery",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201209-303"
}
],
"trust": 0.6
}
}
VAR-201209-0224
Vulnerability from variot - Updated: 2023-12-18 12:58Multiple cross-site scripting (XSS) vulnerabilities in WebNavigator in Siemens WinCC 7.0 SP3 and earlier, as used in SIMATIC PCS7 and other products, allow remote attackers to inject arbitrary web script or HTML via a (1) GET parameter, (2) POST parameter, or (3) Referer HTTP header. Siemens SIMATIC PCS7 And used in other products Siemens WinCC of WebNavigator Contains a cross-site scripting vulnerability.By any third party, any Web Script or HTML May be inserted. (1) GET Parameters (2) POST Parameters (3) Referer HTTP header. A cross-site request forgery vulnerability exists in Siemens SIMATIC WinCC that allows an attacker to build a malicious web page, trick the user into parsing, and perform malicious actions in the target user context. Siemens SIMATIC is an automation software in a single engineering environment. Part of the input passed to the WebNavigator component lacks filtering before returning to the user, and can be exploited for cross-site scripting attacks to obtain sensitive information or hijack user sessions. Siemens SIMATIC WinCC is prone to information-disclosure, SQL-injection, directory-traversal, and cross-site scripting vulnerabilities because it fails to sufficiently sanitize user-supplied input. The attacker may exploit the information-disclosure issue and directory-traversal issues to gain access to sensitive information that may lead to further attacks. The attacker may exploit the SQL-injection issue to compromise the application, access or modify data, or exploit latent vulnerabilities in the underlying database. An attacker may leverage the cross-site scripting issue to execute arbitrary script code in the browser of an unsuspecting user in the context of the affected site. This may allow the attacker to steal cookie-based authentication credentials and to launch other attacks. Siemens SIMATIC WinCC 7.0 SP3 and prior versions are vulnerable. WinCC flexible is a human-machine interface used in some machine or process applications.
The application allows users to perform certain actions via HTTP requests without performing proper validity checks to verify the requests. This can be exploited to perform certain unspecified actions when a logged-in administrative user visits a specially crafted web page. ----------------------------------------------------------------------
The final version of the CSI 6.0 has been released. Find out why this is not just another Patch Management solution: http://secunia.com/blog/325/
TITLE: Siemens SIMATIC WinCC Multiple Vulnerabilities
SECUNIA ADVISORY ID: SA50568
VERIFY ADVISORY: Secunia.com http://secunia.com/advisories/50568/ Customer Area (Credentials Required) https://ca.secunia.com/?page=viewadvisory&vuln_id=50568
RELEASE DATE: 2012-09-11
DISCUSS ADVISORY: http://secunia.com/advisories/50568/#comments
AVAILABLE ON SITE AND IN CUSTOMER AREA: * Last Update * Popularity * Comments * Criticality Level * Impact * Where * Solution Status * Operating System / Software * CVE Reference(s)
http://secunia.com/advisories/50568/
ONLY AVAILABLE IN CUSTOMER AREA: * Authentication Level * Report Reliability * Secunia PoC * Secunia Analysis * Systems Affected * Approve Distribution * Remediation Status * Secunia CVSS Score * CVSS
https://ca.secunia.com/?page=viewadvisory&vuln_id=50568
ONLY AVAILABLE WITH SECUNIA CSI AND SECUNIA PSI: * AUTOMATED SCANNING
http://secunia.com/vulnerability_scanning/personal/ http://secunia.com/vulnerability_scanning/corporate/wsus_sccm_3rd_third_party_patching/
DESCRIPTION: Multiple vulnerabilities have been reported in Siemens SIMATIC WinCC, which can be exploited by malicious people to conduct cross-site scripting attacks, conduct SQL injection attacks, and disclose certain sensitive information.
2) Certain input passed to the WebNavigator component is not properly verified before being used to read files. This can be exploited to read arbitrary files via directory traversal sequences.
3) Certain input passed via SOAP messages to the WebNavigator component is not properly sanitised before being used in SQL queries. This can be exploited to manipulate SQL queries by injecting arbitrary SQL code.
4) An error within the ActiveX control can be exploited to disclose the username and password of an authenticated user.
SOLUTION: Apply Update 3.
Further details available in Customer Area: http://secunia.com/vulnerability_intelligence/
PROVIDED AND/OR DISCOVERED BY: The vendor credits Denis Baranov, Sergey Bobrov, Artem Chaykin, Vladimir Kochetkov, Pavel Toporkov, and Timur Yunusov, Positive Technologies.
ORIGINAL ADVISORY: http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-864051.pdf
OTHER REFERENCES: Further details available in Customer Area: http://secunia.com/vulnerability_intelligence/
DEEP LINKS: Further details available in Customer Area: http://secunia.com/vulnerability_intelligence/
EXTENDED DESCRIPTION: Further details available in Customer Area: http://secunia.com/vulnerability_intelligence/
EXTENDED SOLUTION: Further details available in Customer Area: http://secunia.com/vulnerability_intelligence/
EXPLOIT: Further details available in Customer Area: http://secunia.com/vulnerability_intelligence/
About: This Advisory was delivered by Secunia as a free service to help private users keeping their systems up to date against the latest vulnerabilities.
Subscribe: http://secunia.com/advisories/secunia_security_advisories/
Definitions: (Criticality, Where etc.) http://secunia.com/advisories/about_secunia_advisories/
Please Note: Secunia recommends that you verify all advisories you receive by clicking the link. Secunia NEVER sends attached files with advisories. Secunia does not advise people to install third party patches, only use those supplied by the vendor.
Unsubscribe: Secunia Security Advisories http://secunia.com/sec_adv_unsubscribe/?email=packet%40packetstormsecurity.org
Show details on source website
{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-201209-0224",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "wincc",
"scope": "eq",
"trust": 1.6,
"vendor": "siemens",
"version": "7.0"
},
{
"model": "wincc",
"scope": "eq",
"trust": 1.6,
"vendor": "siemens",
"version": "5.0"
},
{
"model": "wincc",
"scope": "eq",
"trust": 1.6,
"vendor": "siemens",
"version": "6.0"
},
{
"model": "simatic pcs7",
"scope": "eq",
"trust": 1.6,
"vendor": "siemens",
"version": "8.0"
},
{
"model": "wincc",
"scope": "lte",
"trust": 1.0,
"vendor": "siemens",
"version": "7.0"
},
{
"model": null,
"scope": "eq",
"trust": 0.8,
"vendor": "wincc",
"version": "6.0"
},
{
"model": "simatic pcs 7",
"scope": null,
"trust": 0.8,
"vendor": "siemens",
"version": null
},
{
"model": "simatic wincc",
"scope": "lte",
"trust": 0.8,
"vendor": "siemens",
"version": "7.0 sp3"
},
{
"model": null,
"scope": "eq",
"trust": 0.6,
"vendor": "wincc",
"version": "7.0"
},
{
"model": "simatic wincc",
"scope": "eq",
"trust": 0.6,
"vendor": "siemens",
"version": "6.2"
},
{
"model": "simatic wincc",
"scope": "eq",
"trust": 0.6,
"vendor": "siemens",
"version": "7.x"
},
{
"model": "simatic pcs",
"scope": "eq",
"trust": 0.6,
"vendor": "siemens",
"version": "77.x"
},
{
"model": null,
"scope": "eq",
"trust": 0.4,
"vendor": "wincc",
"version": "5.0"
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "simatic pcs7",
"version": "8.0"
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "wincc",
"version": "*"
}
],
"sources": [
{
"db": "IVD",
"id": "5dd0e308-2353-11e6-abef-000c29c66e3d"
},
{
"db": "CNVD",
"id": "CNVD-2012-5088"
},
{
"db": "CNVD",
"id": "CNVD-2012-5084"
},
{
"db": "JVNDB",
"id": "JVNDB-2012-004448"
},
{
"db": "NVD",
"id": "CVE-2012-3031"
},
{
"db": "CNNVD",
"id": "CNNVD-201209-294"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:a:siemens:wincc:*:sp3:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "7.0",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:wincc:7.0:sp2:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:wincc:7.0:sp1:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:simatic_pcs7:8.0:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:wincc:6.0:sp3:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:wincc:7.0:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:wincc:6.0:sp4:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:wincc:6.0:sp2:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:wincc:6.0:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:wincc:5.0:sp1:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:wincc:5.0:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2012-3031"
}
]
},
"credits": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/credits#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Pavel Toporkov,Denis Baranov Sergey Bobrov, Artem Chaykin,Timur Yunusov from Positive Technologies, Vladimir Kochetkov",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201209-294"
}
],
"trust": 0.6
},
"cve": "CVE-2012-3031",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"acInsufInfo": false,
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "NVD",
"availabilityImpact": "NONE",
"baseScore": 4.3,
"confidentialityImpact": "NONE",
"exploitabilityScore": 8.6,
"impactScore": 2.9,
"integrityImpact": "PARTIAL",
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "MEDIUM",
"trust": 1.0,
"userInteractionRequired": true,
"vectorString": "AV:N/AC:M/Au:N/C:N/I:P/A:N",
"version": "2.0"
},
{
"acInsufInfo": null,
"accessComplexity": "Medium",
"accessVector": "Network",
"authentication": "None",
"author": "NVD",
"availabilityImpact": "None",
"baseScore": 4.3,
"confidentialityImpact": "None",
"exploitabilityScore": null,
"id": "CVE-2012-3031",
"impactScore": null,
"integrityImpact": "Partial",
"obtainAllPrivilege": null,
"obtainOtherPrivilege": null,
"obtainUserPrivilege": null,
"severity": "Medium",
"trust": 0.8,
"userInteractionRequired": null,
"vectorString": "AV:N/AC:M/Au:N/C:N/I:P/A:N",
"version": "2.0"
},
{
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 7.8,
"confidentialityImpact": "NONE",
"exploitabilityScore": 8.6,
"id": "CNVD-2012-5088",
"impactScore": 7.8,
"integrityImpact": "PARTIAL",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:M/Au:N/C:N/I:P/A:C",
"version": "2.0"
},
{
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "IVD",
"availabilityImpact": "NONE",
"baseScore": 4.3,
"confidentialityImpact": "NONE",
"exploitabilityScore": 8.6,
"id": "5dd0e308-2353-11e6-abef-000c29c66e3d",
"impactScore": 2.9,
"integrityImpact": "PARTIAL",
"severity": "MEDIUM",
"trust": 0.2,
"vectorString": "AV:N/AC:M/Au:N/C:N/I:P/A:N",
"version": "2.9 [IVD]"
},
{
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "VULHUB",
"availabilityImpact": "NONE",
"baseScore": 4.3,
"confidentialityImpact": "NONE",
"exploitabilityScore": 8.6,
"id": "VHN-56312",
"impactScore": 2.9,
"integrityImpact": "PARTIAL",
"severity": "MEDIUM",
"trust": 0.1,
"vectorString": "AV:N/AC:M/AU:N/C:N/I:P/A:N",
"version": "2.0"
}
],
"cvssV3": [],
"severity": [
{
"author": "NVD",
"id": "CVE-2012-3031",
"trust": 1.8,
"value": "MEDIUM"
},
{
"author": "CNVD",
"id": "CNVD-2012-5088",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "CNNVD",
"id": "CNNVD-201209-294",
"trust": 0.6,
"value": "MEDIUM"
},
{
"author": "IVD",
"id": "5dd0e308-2353-11e6-abef-000c29c66e3d",
"trust": 0.2,
"value": "MEDIUM"
},
{
"author": "VULHUB",
"id": "VHN-56312",
"trust": 0.1,
"value": "MEDIUM"
}
]
}
],
"sources": [
{
"db": "IVD",
"id": "5dd0e308-2353-11e6-abef-000c29c66e3d"
},
{
"db": "CNVD",
"id": "CNVD-2012-5088"
},
{
"db": "VULHUB",
"id": "VHN-56312"
},
{
"db": "JVNDB",
"id": "JVNDB-2012-004448"
},
{
"db": "NVD",
"id": "CVE-2012-3031"
},
{
"db": "CNNVD",
"id": "CNNVD-201209-294"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Multiple cross-site scripting (XSS) vulnerabilities in WebNavigator in Siemens WinCC 7.0 SP3 and earlier, as used in SIMATIC PCS7 and other products, allow remote attackers to inject arbitrary web script or HTML via a (1) GET parameter, (2) POST parameter, or (3) Referer HTTP header. Siemens SIMATIC PCS7 And used in other products Siemens WinCC of WebNavigator Contains a cross-site scripting vulnerability.By any third party, any Web Script or HTML May be inserted. (1) GET Parameters (2) POST Parameters (3) Referer HTTP header. A cross-site request forgery vulnerability exists in Siemens SIMATIC WinCC that allows an attacker to build a malicious web page, trick the user into parsing, and perform malicious actions in the target user context. Siemens SIMATIC is an automation software in a single engineering environment. Part of the input passed to the WebNavigator component lacks filtering before returning to the user, and can be exploited for cross-site scripting attacks to obtain sensitive information or hijack user sessions. Siemens SIMATIC WinCC is prone to information-disclosure, SQL-injection, directory-traversal, and cross-site scripting vulnerabilities because it fails to sufficiently sanitize user-supplied input. \nThe attacker may exploit the information-disclosure issue and directory-traversal issues to gain access to sensitive information that may lead to further attacks. \nThe attacker may exploit the SQL-injection issue to compromise the application, access or modify data, or exploit latent vulnerabilities in the underlying database. \nAn attacker may leverage the cross-site scripting issue to execute arbitrary script code in the browser of an unsuspecting user in the context of the affected site. This may allow the attacker to steal cookie-based authentication credentials and to launch other attacks. \nSiemens SIMATIC WinCC 7.0 SP3 and prior versions are vulnerable. WinCC flexible is a human-machine interface used in some machine or process applications. \n\nThe application allows users to perform certain actions via HTTP\nrequests without performing proper validity checks to verify the\nrequests. This can be exploited to perform certain unspecified\nactions when a logged-in administrative user visits a specially\ncrafted web page. ----------------------------------------------------------------------\n\nThe final version of the CSI 6.0 has been released. \nFind out why this is not just another Patch Management solution: http://secunia.com/blog/325/\n\n----------------------------------------------------------------------\n\nTITLE:\nSiemens SIMATIC WinCC Multiple Vulnerabilities\n\nSECUNIA ADVISORY ID:\nSA50568\n\nVERIFY ADVISORY:\nSecunia.com\nhttp://secunia.com/advisories/50568/\nCustomer Area (Credentials Required)\nhttps://ca.secunia.com/?page=viewadvisory\u0026vuln_id=50568\n\nRELEASE DATE:\n2012-09-11\n\nDISCUSS ADVISORY:\nhttp://secunia.com/advisories/50568/#comments\n\nAVAILABLE ON SITE AND IN CUSTOMER AREA:\n * Last Update\n * Popularity\n * Comments\n * Criticality Level\n * Impact\n * Where\n * Solution Status\n * Operating System / Software\n * CVE Reference(s)\n\nhttp://secunia.com/advisories/50568/\n\nONLY AVAILABLE IN CUSTOMER AREA:\n * Authentication Level\n * Report Reliability\n * Secunia PoC\n * Secunia Analysis\n * Systems Affected\n * Approve Distribution\n * Remediation Status\n * Secunia CVSS Score\n * CVSS\n\nhttps://ca.secunia.com/?page=viewadvisory\u0026vuln_id=50568\n\nONLY AVAILABLE WITH SECUNIA CSI AND SECUNIA PSI:\n * AUTOMATED SCANNING\n\nhttp://secunia.com/vulnerability_scanning/personal/\nhttp://secunia.com/vulnerability_scanning/corporate/wsus_sccm_3rd_third_party_patching/\n\nDESCRIPTION:\nMultiple vulnerabilities have been reported in Siemens SIMATIC WinCC,\nwhich can be exploited by malicious people to conduct cross-site\nscripting attacks, conduct SQL injection attacks, and disclose\ncertain sensitive information. \n\n2) Certain input passed to the WebNavigator component is not properly\nverified before being used to read files. This can be exploited to\nread arbitrary files via directory traversal sequences. \n\n3) Certain input passed via SOAP messages to the WebNavigator\ncomponent is not properly sanitised before being used in SQL queries. \nThis can be exploited to manipulate SQL queries by injecting arbitrary\nSQL code. \n\n4) An error within the ActiveX control can be exploited to disclose\nthe username and password of an authenticated user. \n\nSOLUTION:\nApply Update 3. \n\nFurther details available in Customer Area:\nhttp://secunia.com/vulnerability_intelligence/\n\nPROVIDED AND/OR DISCOVERED BY:\nThe vendor credits Denis Baranov, Sergey Bobrov, Artem Chaykin,\nVladimir Kochetkov, Pavel Toporkov, and Timur Yunusov, Positive\nTechnologies. \n\nORIGINAL ADVISORY:\nhttp://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-864051.pdf\n\nOTHER REFERENCES:\nFurther details available in Customer Area:\nhttp://secunia.com/vulnerability_intelligence/\n\nDEEP LINKS:\nFurther details available in Customer Area:\nhttp://secunia.com/vulnerability_intelligence/\n\nEXTENDED DESCRIPTION:\nFurther details available in Customer Area:\nhttp://secunia.com/vulnerability_intelligence/\n\nEXTENDED SOLUTION:\nFurther details available in Customer Area:\nhttp://secunia.com/vulnerability_intelligence/\n\nEXPLOIT:\nFurther details available in Customer Area:\nhttp://secunia.com/vulnerability_intelligence/\n\n----------------------------------------------------------------------\n\nAbout:\nThis Advisory was delivered by Secunia as a free service to help\nprivate users keeping their systems up to date against the latest\nvulnerabilities. \n\nSubscribe:\nhttp://secunia.com/advisories/secunia_security_advisories/\n\nDefinitions: (Criticality, Where etc.)\nhttp://secunia.com/advisories/about_secunia_advisories/\n\n\nPlease Note:\nSecunia recommends that you verify all advisories you receive by\nclicking the link. \nSecunia NEVER sends attached files with advisories. \nSecunia does not advise people to install third party patches, only\nuse those supplied by the vendor. \n\n----------------------------------------------------------------------\n\nUnsubscribe: Secunia Security Advisories\nhttp://secunia.com/sec_adv_unsubscribe/?email=packet%40packetstormsecurity.org\n\n----------------------------------------------------------------------\n\n\n",
"sources": [
{
"db": "NVD",
"id": "CVE-2012-3031"
},
{
"db": "JVNDB",
"id": "JVNDB-2012-004448"
},
{
"db": "CNVD",
"id": "CNVD-2012-5088"
},
{
"db": "CNVD",
"id": "CNVD-2012-5084"
},
{
"db": "BID",
"id": "55492"
},
{
"db": "IVD",
"id": "5dd0e308-2353-11e6-abef-000c29c66e3d"
},
{
"db": "VULHUB",
"id": "VHN-56312"
},
{
"db": "PACKETSTORM",
"id": "116445"
},
{
"db": "PACKETSTORM",
"id": "116447"
}
],
"trust": 3.42
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2012-3031",
"trust": 4.2
},
{
"db": "SIEMENS",
"id": "SSA-864051",
"trust": 2.5
},
{
"db": "ICS CERT",
"id": "ICSA-12-256-01",
"trust": 1.9
},
{
"db": "CNNVD",
"id": "CNNVD-201209-294",
"trust": 0.9
},
{
"db": "CNVD",
"id": "CNVD-2012-5084",
"trust": 0.8
},
{
"db": "JVNDB",
"id": "JVNDB-2012-004448",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2012-5088",
"trust": 0.6
},
{
"db": "NSFOCUS",
"id": "47149",
"trust": 0.6
},
{
"db": "BID",
"id": "55492",
"trust": 0.3
},
{
"db": "IVD",
"id": "5DD0E308-2353-11E6-ABEF-000C29C66E3D",
"trust": 0.2
},
{
"db": "SECUNIA",
"id": "50581",
"trust": 0.2
},
{
"db": "SECUNIA",
"id": "50568",
"trust": 0.2
},
{
"db": "VULHUB",
"id": "VHN-56312",
"trust": 0.1
},
{
"db": "PACKETSTORM",
"id": "116445",
"trust": 0.1
},
{
"db": "PACKETSTORM",
"id": "116447",
"trust": 0.1
}
],
"sources": [
{
"db": "IVD",
"id": "5dd0e308-2353-11e6-abef-000c29c66e3d"
},
{
"db": "CNVD",
"id": "CNVD-2012-5088"
},
{
"db": "CNVD",
"id": "CNVD-2012-5084"
},
{
"db": "VULHUB",
"id": "VHN-56312"
},
{
"db": "BID",
"id": "55492"
},
{
"db": "JVNDB",
"id": "JVNDB-2012-004448"
},
{
"db": "PACKETSTORM",
"id": "116445"
},
{
"db": "PACKETSTORM",
"id": "116447"
},
{
"db": "NVD",
"id": "CVE-2012-3031"
},
{
"db": "CNNVD",
"id": "CNNVD-201209-294"
}
]
},
"id": "VAR-201209-0224",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "IVD",
"id": "5dd0e308-2353-11e6-abef-000c29c66e3d"
},
{
"db": "CNVD",
"id": "CNVD-2012-5088"
},
{
"db": "CNVD",
"id": "CNVD-2012-5084"
},
{
"db": "VULHUB",
"id": "VHN-56312"
}
],
"trust": 2.09052891
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"ICS"
],
"sub_category": null,
"trust": 1.4
}
],
"sources": [
{
"db": "IVD",
"id": "5dd0e308-2353-11e6-abef-000c29c66e3d"
},
{
"db": "CNVD",
"id": "CNVD-2012-5088"
},
{
"db": "CNVD",
"id": "CNVD-2012-5084"
}
]
},
"last_update_date": "2023-12-18T12:58:16.194000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Top Page",
"trust": 0.8,
"url": "http://www.siemens.com/"
},
{
"title": "SSA-864051: Multiple Vulnerabilities in WinCC 7.0 SP3",
"trust": 0.8,
"url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-864051.pdf"
},
{
"title": "\u30b7\u30fc\u30e1\u30f3\u30b9\u30bd\u30ea\u30e5\u30fc\u30b7\u30e7\u30f3\u30d1\u30fc\u30c8\u30ca\u30fc",
"trust": 0.8,
"url": "http://www.automation.siemens.com/automation/jp/ja/solutionpartner/pages/default.aspx"
},
{
"title": "\u30b7\u30fc\u30e1\u30f3\u30b9\u30fb\u30b8\u30e3\u30d1\u30f3\u682a\u5f0f\u4f1a\u793e",
"trust": 0.8,
"url": "http://www.siemens.com/entry/jp/ja/"
},
{
"title": "Patch for Siemens SIMATIC WinCC Cross-Site Request Forgery Vulnerability",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchinfo/show/80787"
},
{
"title": "Patch for Siemens SIMATIC WinCC Cross-Site Scripting Vulnerability",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchinfo/show/22132"
},
{
"title": "WinCC_V70_SP3_Upd4",
"trust": 0.6,
"url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=44861"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2012-5088"
},
{
"db": "CNVD",
"id": "CNVD-2012-5084"
},
{
"db": "JVNDB",
"id": "JVNDB-2012-004448"
},
{
"db": "CNNVD",
"id": "CNNVD-201209-294"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-79",
"trust": 1.9
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-56312"
},
{
"db": "JVNDB",
"id": "JVNDB-2012-004448"
},
{
"db": "NVD",
"id": "CVE-2012-3031"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.9,
"url": "http://www.us-cert.gov/control_systems/pdf/icsa-12-256-01.pdf"
},
{
"trust": 1.3,
"url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-864051.pdf"
},
{
"trust": 1.1,
"url": "http://en.securitylab.ru/lab/pt-2012-42"
},
{
"trust": 0.8,
"url": "http://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2012-3031"
},
{
"trust": 0.8,
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnid=cve-2012-3031"
},
{
"trust": 0.6,
"url": "http://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-864051.pdf"
},
{
"trust": 0.6,
"url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-864051.pdfhttp"
},
{
"trust": 0.6,
"url": "http://www.nsfocus.net/vulndb/47149"
},
{
"trust": 0.3,
"url": "http://aunz.siemens.com/newscentre/productreleases/pages/iac_pr_simaticwinccv62.aspx"
},
{
"trust": 0.2,
"url": "http://secunia.com/vulnerability_intelligence/"
},
{
"trust": 0.2,
"url": "http://secunia.com/advisories/secunia_security_advisories/"
},
{
"trust": 0.2,
"url": "http://secunia.com/vulnerability_scanning/corporate/wsus_sccm_3rd_third_party_patching/"
},
{
"trust": 0.2,
"url": "http://secunia.com/vulnerability_scanning/personal/"
},
{
"trust": 0.2,
"url": "http://secunia.com/sec_adv_unsubscribe/?email=packet%40packetstormsecurity.org"
},
{
"trust": 0.2,
"url": "http://secunia.com/blog/325/"
},
{
"trust": 0.2,
"url": "http://secunia.com/advisories/about_secunia_advisories/"
},
{
"trust": 0.1,
"url": "https://ca.secunia.com/?page=viewadvisory\u0026vuln_id=50581"
},
{
"trust": 0.1,
"url": "http://secunia.com/advisories/50581/#comments"
},
{
"trust": 0.1,
"url": "http://secunia.com/advisories/50581/"
},
{
"trust": 0.1,
"url": "http://secunia.com/advisories/50568/"
},
{
"trust": 0.1,
"url": "http://secunia.com/advisories/50568/#comments"
},
{
"trust": 0.1,
"url": "https://ca.secunia.com/?page=viewadvisory\u0026vuln_id=50568"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2012-5088"
},
{
"db": "CNVD",
"id": "CNVD-2012-5084"
},
{
"db": "VULHUB",
"id": "VHN-56312"
},
{
"db": "BID",
"id": "55492"
},
{
"db": "JVNDB",
"id": "JVNDB-2012-004448"
},
{
"db": "PACKETSTORM",
"id": "116445"
},
{
"db": "PACKETSTORM",
"id": "116447"
},
{
"db": "NVD",
"id": "CVE-2012-3031"
},
{
"db": "CNNVD",
"id": "CNNVD-201209-294"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "IVD",
"id": "5dd0e308-2353-11e6-abef-000c29c66e3d"
},
{
"db": "CNVD",
"id": "CNVD-2012-5088"
},
{
"db": "CNVD",
"id": "CNVD-2012-5084"
},
{
"db": "VULHUB",
"id": "VHN-56312"
},
{
"db": "BID",
"id": "55492"
},
{
"db": "JVNDB",
"id": "JVNDB-2012-004448"
},
{
"db": "PACKETSTORM",
"id": "116445"
},
{
"db": "PACKETSTORM",
"id": "116447"
},
{
"db": "NVD",
"id": "CVE-2012-3031"
},
{
"db": "CNNVD",
"id": "CNNVD-201209-294"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2012-09-13T00:00:00",
"db": "IVD",
"id": "5dd0e308-2353-11e6-abef-000c29c66e3d"
},
{
"date": "2012-09-13T00:00:00",
"db": "CNVD",
"id": "CNVD-2012-5088"
},
{
"date": "2012-09-13T00:00:00",
"db": "CNVD",
"id": "CNVD-2012-5084"
},
{
"date": "2012-09-18T00:00:00",
"db": "VULHUB",
"id": "VHN-56312"
},
{
"date": "2012-09-11T00:00:00",
"db": "BID",
"id": "55492"
},
{
"date": "2012-09-20T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2012-004448"
},
{
"date": "2012-09-11T07:30:00",
"db": "PACKETSTORM",
"id": "116445"
},
{
"date": "2012-09-11T07:30:06",
"db": "PACKETSTORM",
"id": "116447"
},
{
"date": "2012-09-18T14:55:01.490000",
"db": "NVD",
"id": "CVE-2012-3031"
},
{
"date": "2012-09-18T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201209-294"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2016-08-26T00:00:00",
"db": "CNVD",
"id": "CNVD-2012-5088"
},
{
"date": "2012-09-13T00:00:00",
"db": "CNVD",
"id": "CNVD-2012-5084"
},
{
"date": "2012-09-19T00:00:00",
"db": "VULHUB",
"id": "VHN-56312"
},
{
"date": "2012-09-12T22:50:00",
"db": "BID",
"id": "55492"
},
{
"date": "2012-09-20T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2012-004448"
},
{
"date": "2012-09-19T04:00:00",
"db": "NVD",
"id": "CVE-2012-3031"
},
{
"date": "2020-07-14T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201209-294"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201209-294"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Siemens SIMATIC WinCC Cross-Site Scripting Vulnerability",
"sources": [
{
"db": "IVD",
"id": "5dd0e308-2353-11e6-abef-000c29c66e3d"
},
{
"db": "CNVD",
"id": "CNVD-2012-5084"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "XSS",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201209-294"
}
],
"trust": 0.6
}
}
VAR-201209-0226
Vulnerability from variot - Updated: 2023-12-18 12:58WebNavigator in Siemens WinCC 7.0 SP3 and earlier, as used in SIMATIC PCS7 and other products, allows remote attackers to discover a username and password via crafted parameters to unspecified methods in ActiveX controls. Siemens SIMATIC is an automation software in a single engineering environment. Siemens SIMATIC WinCC is prone to information-disclosure, SQL-injection, directory-traversal, and cross-site scripting vulnerabilities because it fails to sufficiently sanitize user-supplied input. The attacker may exploit the information-disclosure issue and directory-traversal issues to gain access to sensitive information that may lead to further attacks. The attacker may exploit the SQL-injection issue to compromise the application, access or modify data, or exploit latent vulnerabilities in the underlying database. An attacker may leverage the cross-site scripting issue to execute arbitrary script code in the browser of an unsuspecting user in the context of the affected site. This may allow the attacker to steal cookie-based authentication credentials and to launch other attacks. Siemens SIMATIC WinCC 7.0 SP3 and prior versions are vulnerable. WinCC flexible is a human-machine interface used in some machine or process applications.
The application allows users to perform certain actions via HTTP requests without performing proper validity checks to verify the requests. This can be exploited to perform certain unspecified actions when a logged-in administrative user visits a specially crafted web page. ----------------------------------------------------------------------
The final version of the CSI 6.0 has been released. Find out why this is not just another Patch Management solution: http://secunia.com/blog/325/
TITLE: Siemens SIMATIC WinCC Multiple Vulnerabilities
SECUNIA ADVISORY ID: SA50568
VERIFY ADVISORY: Secunia.com http://secunia.com/advisories/50568/ Customer Area (Credentials Required) https://ca.secunia.com/?page=viewadvisory&vuln_id=50568
RELEASE DATE: 2012-09-11
DISCUSS ADVISORY: http://secunia.com/advisories/50568/#comments
AVAILABLE ON SITE AND IN CUSTOMER AREA: * Last Update * Popularity * Comments * Criticality Level * Impact * Where * Solution Status * Operating System / Software * CVE Reference(s)
http://secunia.com/advisories/50568/
ONLY AVAILABLE IN CUSTOMER AREA: * Authentication Level * Report Reliability * Secunia PoC * Secunia Analysis * Systems Affected * Approve Distribution * Remediation Status * Secunia CVSS Score * CVSS
https://ca.secunia.com/?page=viewadvisory&vuln_id=50568
ONLY AVAILABLE WITH SECUNIA CSI AND SECUNIA PSI: * AUTOMATED SCANNING
http://secunia.com/vulnerability_scanning/personal/ http://secunia.com/vulnerability_scanning/corporate/wsus_sccm_3rd_third_party_patching/
DESCRIPTION: Multiple vulnerabilities have been reported in Siemens SIMATIC WinCC, which can be exploited by malicious people to conduct cross-site scripting attacks, conduct SQL injection attacks, and disclose certain sensitive information.
1) Certain unspecified input passed to the WebNavigator component is not properly sanitised before being returned to the user.
2) Certain input passed to the WebNavigator component is not properly verified before being used to read files. This can be exploited to read arbitrary files via directory traversal sequences.
3) Certain input passed via SOAP messages to the WebNavigator component is not properly sanitised before being used in SQL queries. This can be exploited to manipulate SQL queries by injecting arbitrary SQL code.
SOLUTION: Apply Update 3.
Further details available in Customer Area: http://secunia.com/vulnerability_intelligence/
PROVIDED AND/OR DISCOVERED BY: The vendor credits Denis Baranov, Sergey Bobrov, Artem Chaykin, Vladimir Kochetkov, Pavel Toporkov, and Timur Yunusov, Positive Technologies.
ORIGINAL ADVISORY: http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-864051.pdf
OTHER REFERENCES: Further details available in Customer Area: http://secunia.com/vulnerability_intelligence/
DEEP LINKS: Further details available in Customer Area: http://secunia.com/vulnerability_intelligence/
EXTENDED DESCRIPTION: Further details available in Customer Area: http://secunia.com/vulnerability_intelligence/
EXTENDED SOLUTION: Further details available in Customer Area: http://secunia.com/vulnerability_intelligence/
EXPLOIT: Further details available in Customer Area: http://secunia.com/vulnerability_intelligence/
About: This Advisory was delivered by Secunia as a free service to help private users keeping their systems up to date against the latest vulnerabilities.
Subscribe: http://secunia.com/advisories/secunia_security_advisories/
Definitions: (Criticality, Where etc.) http://secunia.com/advisories/about_secunia_advisories/
Please Note: Secunia recommends that you verify all advisories you receive by clicking the link. Secunia NEVER sends attached files with advisories. Secunia does not advise people to install third party patches, only use those supplied by the vendor.
Unsubscribe: Secunia Security Advisories http://secunia.com/sec_adv_unsubscribe/?email=packet%40packetstormsecurity.org
Show details on source website
{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-201209-0226",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "wincc",
"scope": "eq",
"trust": 1.6,
"vendor": "siemens",
"version": "7.0"
},
{
"model": "wincc",
"scope": "eq",
"trust": 1.6,
"vendor": "siemens",
"version": "5.0"
},
{
"model": "wincc",
"scope": "eq",
"trust": 1.6,
"vendor": "siemens",
"version": "6.0"
},
{
"model": "simatic pcs7",
"scope": "eq",
"trust": 1.6,
"vendor": "siemens",
"version": "8.0"
},
{
"model": "wincc",
"scope": "lte",
"trust": 1.0,
"vendor": "siemens",
"version": "7.0"
},
{
"model": null,
"scope": "eq",
"trust": 0.8,
"vendor": "wincc",
"version": "6.0"
},
{
"model": "simatic pcs 7",
"scope": null,
"trust": 0.8,
"vendor": "siemens",
"version": null
},
{
"model": "simatic wincc",
"scope": "lte",
"trust": 0.8,
"vendor": "siemens",
"version": "7.0 sp3"
},
{
"model": null,
"scope": "eq",
"trust": 0.6,
"vendor": "wincc",
"version": "7.0"
},
{
"model": "simatic wincc",
"scope": "eq",
"trust": 0.6,
"vendor": "siemens",
"version": "7.x"
},
{
"model": "simatic pcs",
"scope": "eq",
"trust": 0.6,
"vendor": "siemens",
"version": "77.x"
},
{
"model": null,
"scope": "eq",
"trust": 0.4,
"vendor": "wincc",
"version": "5.0"
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "simatic pcs7",
"version": "8.0"
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "wincc",
"version": "*"
}
],
"sources": [
{
"db": "IVD",
"id": "5e11d08e-2353-11e6-abef-000c29c66e3d"
},
{
"db": "CNVD",
"id": "CNVD-2012-5087"
},
{
"db": "JVNDB",
"id": "JVNDB-2012-004450"
},
{
"db": "NVD",
"id": "CVE-2012-3034"
},
{
"db": "CNNVD",
"id": "CNNVD-201209-296"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:a:siemens:wincc:6.0:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:wincc:5.0:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:wincc:5.0:sp1:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:wincc:*:sp3:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "7.0",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:wincc:7.0:sp2:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:wincc:7.0:sp1:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:wincc:7.0:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:simatic_pcs7:8.0:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:wincc:6.0:sp2:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:wincc:6.0:sp4:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:wincc:6.0:sp3:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2012-3034"
}
]
},
"credits": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/credits#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Denis Baranov Sergey Bobrov, Artem Chaykin, Vladimir Kochetkov, Pavel Toporkov,Timur Yunusov from Positive Technologies",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201209-296"
}
],
"trust": 0.6
},
"cve": "CVE-2012-3034",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"acInsufInfo": false,
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "NVD",
"availabilityImpact": "NONE",
"baseScore": 4.3,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 8.6,
"impactScore": 2.9,
"integrityImpact": "NONE",
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "MEDIUM",
"trust": 1.0,
"userInteractionRequired": false,
"vectorString": "AV:N/AC:M/Au:N/C:P/I:N/A:N",
"version": "2.0"
},
{
"acInsufInfo": null,
"accessComplexity": "Medium",
"accessVector": "Network",
"authentication": "None",
"author": "NVD",
"availabilityImpact": "None",
"baseScore": 4.3,
"confidentialityImpact": "Partial",
"exploitabilityScore": null,
"id": "CVE-2012-3034",
"impactScore": null,
"integrityImpact": "None",
"obtainAllPrivilege": null,
"obtainOtherPrivilege": null,
"obtainUserPrivilege": null,
"severity": "Medium",
"trust": 0.9,
"userInteractionRequired": null,
"vectorString": "AV:N/AC:M/Au:N/C:P/I:N/A:N",
"version": "2.0"
},
{
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "IVD",
"availabilityImpact": "NONE",
"baseScore": 4.3,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 8.6,
"id": "5e11d08e-2353-11e6-abef-000c29c66e3d",
"impactScore": 2.9,
"integrityImpact": "NONE",
"severity": "MEDIUM",
"trust": 0.2,
"vectorString": "AV:N/AC:M/Au:N/C:P/I:N/A:N",
"version": "2.9 [IVD]"
},
{
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "VULHUB",
"availabilityImpact": "NONE",
"baseScore": 4.3,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 8.6,
"id": "VHN-56315",
"impactScore": 2.9,
"integrityImpact": "NONE",
"severity": "MEDIUM",
"trust": 0.1,
"vectorString": "AV:N/AC:M/AU:N/C:P/I:N/A:N",
"version": "2.0"
}
],
"cvssV3": [],
"severity": [
{
"author": "NVD",
"id": "CVE-2012-3034",
"trust": 1.8,
"value": "MEDIUM"
},
{
"author": "CNNVD",
"id": "CNNVD-201209-296",
"trust": 0.6,
"value": "MEDIUM"
},
{
"author": "IVD",
"id": "5e11d08e-2353-11e6-abef-000c29c66e3d",
"trust": 0.2,
"value": "MEDIUM"
},
{
"author": "VULHUB",
"id": "VHN-56315",
"trust": 0.1,
"value": "MEDIUM"
},
{
"author": "VULMON",
"id": "CVE-2012-3034",
"trust": 0.1,
"value": "MEDIUM"
}
]
}
],
"sources": [
{
"db": "IVD",
"id": "5e11d08e-2353-11e6-abef-000c29c66e3d"
},
{
"db": "VULHUB",
"id": "VHN-56315"
},
{
"db": "VULMON",
"id": "CVE-2012-3034"
},
{
"db": "JVNDB",
"id": "JVNDB-2012-004450"
},
{
"db": "NVD",
"id": "CVE-2012-3034"
},
{
"db": "CNNVD",
"id": "CNNVD-201209-296"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "WebNavigator in Siemens WinCC 7.0 SP3 and earlier, as used in SIMATIC PCS7 and other products, allows remote attackers to discover a username and password via crafted parameters to unspecified methods in ActiveX controls. Siemens SIMATIC is an automation software in a single engineering environment. Siemens SIMATIC WinCC is prone to information-disclosure, SQL-injection, directory-traversal, and cross-site scripting vulnerabilities because it fails to sufficiently sanitize user-supplied input. \nThe attacker may exploit the information-disclosure issue and directory-traversal issues to gain access to sensitive information that may lead to further attacks. \nThe attacker may exploit the SQL-injection issue to compromise the application, access or modify data, or exploit latent vulnerabilities in the underlying database. \nAn attacker may leverage the cross-site scripting issue to execute arbitrary script code in the browser of an unsuspecting user in the context of the affected site. This may allow the attacker to steal cookie-based authentication credentials and to launch other attacks. \nSiemens SIMATIC WinCC 7.0 SP3 and prior versions are vulnerable. WinCC flexible is a human-machine interface used in some machine or process applications. \n\nThe application allows users to perform certain actions via HTTP\nrequests without performing proper validity checks to verify the\nrequests. This can be exploited to perform certain unspecified\nactions when a logged-in administrative user visits a specially\ncrafted web page. ----------------------------------------------------------------------\n\nThe final version of the CSI 6.0 has been released. \nFind out why this is not just another Patch Management solution: http://secunia.com/blog/325/\n\n----------------------------------------------------------------------\n\nTITLE:\nSiemens SIMATIC WinCC Multiple Vulnerabilities\n\nSECUNIA ADVISORY ID:\nSA50568\n\nVERIFY ADVISORY:\nSecunia.com\nhttp://secunia.com/advisories/50568/\nCustomer Area (Credentials Required)\nhttps://ca.secunia.com/?page=viewadvisory\u0026vuln_id=50568\n\nRELEASE DATE:\n2012-09-11\n\nDISCUSS ADVISORY:\nhttp://secunia.com/advisories/50568/#comments\n\nAVAILABLE ON SITE AND IN CUSTOMER AREA:\n * Last Update\n * Popularity\n * Comments\n * Criticality Level\n * Impact\n * Where\n * Solution Status\n * Operating System / Software\n * CVE Reference(s)\n\nhttp://secunia.com/advisories/50568/\n\nONLY AVAILABLE IN CUSTOMER AREA:\n * Authentication Level\n * Report Reliability\n * Secunia PoC\n * Secunia Analysis\n * Systems Affected\n * Approve Distribution\n * Remediation Status\n * Secunia CVSS Score\n * CVSS\n\nhttps://ca.secunia.com/?page=viewadvisory\u0026vuln_id=50568\n\nONLY AVAILABLE WITH SECUNIA CSI AND SECUNIA PSI:\n * AUTOMATED SCANNING\n\nhttp://secunia.com/vulnerability_scanning/personal/\nhttp://secunia.com/vulnerability_scanning/corporate/wsus_sccm_3rd_third_party_patching/\n\nDESCRIPTION:\nMultiple vulnerabilities have been reported in Siemens SIMATIC WinCC,\nwhich can be exploited by malicious people to conduct cross-site\nscripting attacks, conduct SQL injection attacks, and disclose\ncertain sensitive information. \n\n1) Certain unspecified input passed to the WebNavigator component is\nnot properly sanitised before being returned to the user. \n\n2) Certain input passed to the WebNavigator component is not properly\nverified before being used to read files. This can be exploited to\nread arbitrary files via directory traversal sequences. \n\n3) Certain input passed via SOAP messages to the WebNavigator\ncomponent is not properly sanitised before being used in SQL queries. \nThis can be exploited to manipulate SQL queries by injecting arbitrary\nSQL code. \n\nSOLUTION:\nApply Update 3. \n\nFurther details available in Customer Area:\nhttp://secunia.com/vulnerability_intelligence/\n\nPROVIDED AND/OR DISCOVERED BY:\nThe vendor credits Denis Baranov, Sergey Bobrov, Artem Chaykin,\nVladimir Kochetkov, Pavel Toporkov, and Timur Yunusov, Positive\nTechnologies. \n\nORIGINAL ADVISORY:\nhttp://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-864051.pdf\n\nOTHER REFERENCES:\nFurther details available in Customer Area:\nhttp://secunia.com/vulnerability_intelligence/\n\nDEEP LINKS:\nFurther details available in Customer Area:\nhttp://secunia.com/vulnerability_intelligence/\n\nEXTENDED DESCRIPTION:\nFurther details available in Customer Area:\nhttp://secunia.com/vulnerability_intelligence/\n\nEXTENDED SOLUTION:\nFurther details available in Customer Area:\nhttp://secunia.com/vulnerability_intelligence/\n\nEXPLOIT:\nFurther details available in Customer Area:\nhttp://secunia.com/vulnerability_intelligence/\n\n----------------------------------------------------------------------\n\nAbout:\nThis Advisory was delivered by Secunia as a free service to help\nprivate users keeping their systems up to date against the latest\nvulnerabilities. \n\nSubscribe:\nhttp://secunia.com/advisories/secunia_security_advisories/\n\nDefinitions: (Criticality, Where etc.)\nhttp://secunia.com/advisories/about_secunia_advisories/\n\n\nPlease Note:\nSecunia recommends that you verify all advisories you receive by\nclicking the link. \nSecunia NEVER sends attached files with advisories. \nSecunia does not advise people to install third party patches, only\nuse those supplied by the vendor. \n\n----------------------------------------------------------------------\n\nUnsubscribe: Secunia Security Advisories\nhttp://secunia.com/sec_adv_unsubscribe/?email=packet%40packetstormsecurity.org\n\n----------------------------------------------------------------------\n\n\n",
"sources": [
{
"db": "NVD",
"id": "CVE-2012-3034"
},
{
"db": "JVNDB",
"id": "JVNDB-2012-004450"
},
{
"db": "CNVD",
"id": "CNVD-2012-5087"
},
{
"db": "BID",
"id": "55492"
},
{
"db": "IVD",
"id": "5e11d08e-2353-11e6-abef-000c29c66e3d"
},
{
"db": "VULHUB",
"id": "VHN-56315"
},
{
"db": "VULMON",
"id": "CVE-2012-3034"
},
{
"db": "PACKETSTORM",
"id": "116445"
},
{
"db": "PACKETSTORM",
"id": "116447"
}
],
"trust": 2.97
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2012-3034",
"trust": 3.7
},
{
"db": "SIEMENS",
"id": "SSA-864051",
"trust": 2.6
},
{
"db": "ICS CERT",
"id": "ICSA-12-256-01",
"trust": 2.6
},
{
"db": "CNNVD",
"id": "CNNVD-201209-296",
"trust": 0.9
},
{
"db": "BID",
"id": "55492",
"trust": 0.9
},
{
"db": "CNVD",
"id": "CNVD-2012-5087",
"trust": 0.8
},
{
"db": "JVNDB",
"id": "JVNDB-2012-004450",
"trust": 0.8
},
{
"db": "SECUNIA",
"id": "50568",
"trust": 0.8
},
{
"db": "NSFOCUS",
"id": "20651",
"trust": 0.6
},
{
"db": "NSFOCUS",
"id": "20931",
"trust": 0.6
},
{
"db": "IVD",
"id": "5E11D08E-2353-11E6-ABEF-000C29C66E3D",
"trust": 0.2
},
{
"db": "SECUNIA",
"id": "50581",
"trust": 0.2
},
{
"db": "VULHUB",
"id": "VHN-56315",
"trust": 0.1
},
{
"db": "VULMON",
"id": "CVE-2012-3034",
"trust": 0.1
},
{
"db": "PACKETSTORM",
"id": "116445",
"trust": 0.1
},
{
"db": "PACKETSTORM",
"id": "116447",
"trust": 0.1
}
],
"sources": [
{
"db": "IVD",
"id": "5e11d08e-2353-11e6-abef-000c29c66e3d"
},
{
"db": "CNVD",
"id": "CNVD-2012-5087"
},
{
"db": "VULHUB",
"id": "VHN-56315"
},
{
"db": "VULMON",
"id": "CVE-2012-3034"
},
{
"db": "BID",
"id": "55492"
},
{
"db": "JVNDB",
"id": "JVNDB-2012-004450"
},
{
"db": "PACKETSTORM",
"id": "116445"
},
{
"db": "PACKETSTORM",
"id": "116447"
},
{
"db": "NVD",
"id": "CVE-2012-3034"
},
{
"db": "CNNVD",
"id": "CNNVD-201209-296"
}
]
},
"id": "VAR-201209-0226",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "IVD",
"id": "5e11d08e-2353-11e6-abef-000c29c66e3d"
},
{
"db": "CNVD",
"id": "CNVD-2012-5087"
},
{
"db": "VULHUB",
"id": "VHN-56315"
}
],
"trust": 1.49052891
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"ICS"
],
"sub_category": null,
"trust": 0.8
}
],
"sources": [
{
"db": "IVD",
"id": "5e11d08e-2353-11e6-abef-000c29c66e3d"
},
{
"db": "CNVD",
"id": "CNVD-2012-5087"
}
]
},
"last_update_date": "2023-12-18T12:58:16.293000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Top Page",
"trust": 0.8,
"url": "http://www.siemens.com/"
},
{
"title": "SSA-864051: Multiple Vulnerabilities in WinCC 7.0 SP3",
"trust": 0.8,
"url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-864051.pdf"
},
{
"title": "\u30b7\u30fc\u30e1\u30f3\u30b9\u30bd\u30ea\u30e5\u30fc\u30b7\u30e7\u30f3\u30d1\u30fc\u30c8\u30ca\u30fc",
"trust": 0.8,
"url": "http://www.automation.siemens.com/automation/jp/ja/solutionpartner/pages/default.aspx"
},
{
"title": "\u30b7\u30fc\u30e1\u30f3\u30b9\u30fb\u30b8\u30e3\u30d1\u30f3\u682a\u5f0f\u4f1a\u793e",
"trust": 0.8,
"url": "http://www.siemens.com/entry/jp/ja/"
},
{
"title": "Patch for Siemens SIMATIC WinCC ActiveX Control Account Information Disclosure Vulnerability",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchinfo/show/22134"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2012-5087"
},
{
"db": "JVNDB",
"id": "JVNDB-2012-004450"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-200",
"trust": 1.9
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-56315"
},
{
"db": "JVNDB",
"id": "JVNDB-2012-004450"
},
{
"db": "NVD",
"id": "CVE-2012-3034"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.6,
"url": "http://www.us-cert.gov/control_systems/pdf/icsa-12-256-01.pdf"
},
{
"trust": 2.0,
"url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-864051.pdf"
},
{
"trust": 1.8,
"url": "http://en.securitylab.ru/lab/pt-2012-45"
},
{
"trust": 0.8,
"url": "http://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2012-3034"
},
{
"trust": 0.8,
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnid=cve-2012-3034"
},
{
"trust": 0.6,
"url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-864051.pdfhttp"
},
{
"trust": 0.6,
"url": "http://secunia.com/advisories/50568"
},
{
"trust": 0.6,
"url": "http://www.securityfocus.com/bid/55492"
},
{
"trust": 0.6,
"url": "http://www.nsfocus.net/vulndb/20931"
},
{
"trust": 0.6,
"url": "http://www.nsfocus.net/vulndb/20651"
},
{
"trust": 0.3,
"url": "http://aunz.siemens.com/newscentre/productreleases/pages/iac_pr_simaticwinccv62.aspx"
},
{
"trust": 0.2,
"url": "http://secunia.com/vulnerability_intelligence/"
},
{
"trust": 0.2,
"url": "http://secunia.com/advisories/secunia_security_advisories/"
},
{
"trust": 0.2,
"url": "http://secunia.com/vulnerability_scanning/corporate/wsus_sccm_3rd_third_party_patching/"
},
{
"trust": 0.2,
"url": "http://secunia.com/vulnerability_scanning/personal/"
},
{
"trust": 0.2,
"url": "http://secunia.com/sec_adv_unsubscribe/?email=packet%40packetstormsecurity.org"
},
{
"trust": 0.2,
"url": "http://secunia.com/blog/325/"
},
{
"trust": 0.2,
"url": "http://secunia.com/advisories/about_secunia_advisories/"
},
{
"trust": 0.1,
"url": "https://cwe.mitre.org/data/definitions/200.html"
},
{
"trust": 0.1,
"url": "https://nvd.nist.gov"
},
{
"trust": 0.1,
"url": "http://tools.cisco.com/security/center/viewalert.x?alertid=26911"
},
{
"trust": 0.1,
"url": "https://ics-cert.us-cert.gov/advisories/icsa-12-256-01"
},
{
"trust": 0.1,
"url": "https://ca.secunia.com/?page=viewadvisory\u0026vuln_id=50581"
},
{
"trust": 0.1,
"url": "http://secunia.com/advisories/50581/#comments"
},
{
"trust": 0.1,
"url": "http://secunia.com/advisories/50581/"
},
{
"trust": 0.1,
"url": "http://secunia.com/advisories/50568/"
},
{
"trust": 0.1,
"url": "http://secunia.com/advisories/50568/#comments"
},
{
"trust": 0.1,
"url": "https://ca.secunia.com/?page=viewadvisory\u0026vuln_id=50568"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2012-5087"
},
{
"db": "VULHUB",
"id": "VHN-56315"
},
{
"db": "VULMON",
"id": "CVE-2012-3034"
},
{
"db": "BID",
"id": "55492"
},
{
"db": "JVNDB",
"id": "JVNDB-2012-004450"
},
{
"db": "PACKETSTORM",
"id": "116445"
},
{
"db": "PACKETSTORM",
"id": "116447"
},
{
"db": "NVD",
"id": "CVE-2012-3034"
},
{
"db": "CNNVD",
"id": "CNNVD-201209-296"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "IVD",
"id": "5e11d08e-2353-11e6-abef-000c29c66e3d"
},
{
"db": "CNVD",
"id": "CNVD-2012-5087"
},
{
"db": "VULHUB",
"id": "VHN-56315"
},
{
"db": "VULMON",
"id": "CVE-2012-3034"
},
{
"db": "BID",
"id": "55492"
},
{
"db": "JVNDB",
"id": "JVNDB-2012-004450"
},
{
"db": "PACKETSTORM",
"id": "116445"
},
{
"db": "PACKETSTORM",
"id": "116447"
},
{
"db": "NVD",
"id": "CVE-2012-3034"
},
{
"db": "CNNVD",
"id": "CNNVD-201209-296"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2012-09-13T00:00:00",
"db": "IVD",
"id": "5e11d08e-2353-11e6-abef-000c29c66e3d"
},
{
"date": "2012-09-13T00:00:00",
"db": "CNVD",
"id": "CNVD-2012-5087"
},
{
"date": "2012-09-18T00:00:00",
"db": "VULHUB",
"id": "VHN-56315"
},
{
"date": "2012-09-18T00:00:00",
"db": "VULMON",
"id": "CVE-2012-3034"
},
{
"date": "2012-09-11T00:00:00",
"db": "BID",
"id": "55492"
},
{
"date": "2012-09-20T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2012-004450"
},
{
"date": "2012-09-11T07:30:00",
"db": "PACKETSTORM",
"id": "116445"
},
{
"date": "2012-09-11T07:30:06",
"db": "PACKETSTORM",
"id": "116447"
},
{
"date": "2012-09-18T14:55:01.583000",
"db": "NVD",
"id": "CVE-2012-3034"
},
{
"date": "2012-09-18T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201209-296"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2012-09-13T00:00:00",
"db": "CNVD",
"id": "CNVD-2012-5087"
},
{
"date": "2012-09-19T00:00:00",
"db": "VULHUB",
"id": "VHN-56315"
},
{
"date": "2012-09-19T00:00:00",
"db": "VULMON",
"id": "CVE-2012-3034"
},
{
"date": "2012-09-12T22:50:00",
"db": "BID",
"id": "55492"
},
{
"date": "2012-09-20T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2012-004450"
},
{
"date": "2012-09-19T14:11:05.407000",
"db": "NVD",
"id": "CVE-2012-3034"
},
{
"date": "2012-09-20T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201209-296"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201209-296"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Siemens SIMATIC WinCC ActiveX Control Account Information Disclosure Vulnerability",
"sources": [
{
"db": "IVD",
"id": "5e11d08e-2353-11e6-abef-000c29c66e3d"
},
{
"db": "CNVD",
"id": "CNVD-2012-5087"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "information disclosure",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201209-296"
}
],
"trust": 0.6
}
}
VAR-201209-0225
Vulnerability from variot - Updated: 2023-12-18 12:58SQL injection vulnerability in WebNavigator in Siemens WinCC 7.0 SP3 and earlier, as used in SIMATIC PCS7 and other products, allows remote attackers to execute arbitrary SQL commands via a crafted SOAP message. Siemens SIMATIC is an automation software in a single engineering environment. Siemens SIMATIC WinCC is prone to information-disclosure, SQL-injection, directory-traversal, and cross-site scripting vulnerabilities because it fails to sufficiently sanitize user-supplied input. The attacker may exploit the information-disclosure issue and directory-traversal issues to gain access to sensitive information that may lead to further attacks. The attacker may exploit the SQL-injection issue to compromise the application, access or modify data, or exploit latent vulnerabilities in the underlying database. An attacker may leverage the cross-site scripting issue to execute arbitrary script code in the browser of an unsuspecting user in the context of the affected site. This may allow the attacker to steal cookie-based authentication credentials and to launch other attacks. Siemens SIMATIC WinCC 7.0 SP3 and prior versions are vulnerable. WinCC flexible is a human-machine interface used in some machine or process applications.
The application allows users to perform certain actions via HTTP requests without performing proper validity checks to verify the requests. This can be exploited to perform certain unspecified actions when a logged-in administrative user visits a specially crafted web page. ----------------------------------------------------------------------
The final version of the CSI 6.0 has been released. Find out why this is not just another Patch Management solution: http://secunia.com/blog/325/
TITLE: Siemens SIMATIC WinCC Multiple Vulnerabilities
SECUNIA ADVISORY ID: SA50568
VERIFY ADVISORY: Secunia.com http://secunia.com/advisories/50568/ Customer Area (Credentials Required) https://ca.secunia.com/?page=viewadvisory&vuln_id=50568
RELEASE DATE: 2012-09-11
DISCUSS ADVISORY: http://secunia.com/advisories/50568/#comments
AVAILABLE ON SITE AND IN CUSTOMER AREA: * Last Update * Popularity * Comments * Criticality Level * Impact * Where * Solution Status * Operating System / Software * CVE Reference(s)
http://secunia.com/advisories/50568/
ONLY AVAILABLE IN CUSTOMER AREA: * Authentication Level * Report Reliability * Secunia PoC * Secunia Analysis * Systems Affected * Approve Distribution * Remediation Status * Secunia CVSS Score * CVSS
https://ca.secunia.com/?page=viewadvisory&vuln_id=50568
ONLY AVAILABLE WITH SECUNIA CSI AND SECUNIA PSI: * AUTOMATED SCANNING
http://secunia.com/vulnerability_scanning/personal/ http://secunia.com/vulnerability_scanning/corporate/wsus_sccm_3rd_third_party_patching/
DESCRIPTION: Multiple vulnerabilities have been reported in Siemens SIMATIC WinCC, which can be exploited by malicious people to conduct cross-site scripting attacks, conduct SQL injection attacks, and disclose certain sensitive information.
1) Certain unspecified input passed to the WebNavigator component is not properly sanitised before being returned to the user.
2) Certain input passed to the WebNavigator component is not properly verified before being used to read files. This can be exploited to read arbitrary files via directory traversal sequences. This can be exploited to manipulate SQL queries by injecting arbitrary SQL code.
4) An error within the ActiveX control can be exploited to disclose the username and password of an authenticated user.
SOLUTION: Apply Update 3.
Further details available in Customer Area: http://secunia.com/vulnerability_intelligence/
PROVIDED AND/OR DISCOVERED BY: The vendor credits Denis Baranov, Sergey Bobrov, Artem Chaykin, Vladimir Kochetkov, Pavel Toporkov, and Timur Yunusov, Positive Technologies.
ORIGINAL ADVISORY: http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-864051.pdf
OTHER REFERENCES: Further details available in Customer Area: http://secunia.com/vulnerability_intelligence/
DEEP LINKS: Further details available in Customer Area: http://secunia.com/vulnerability_intelligence/
EXTENDED DESCRIPTION: Further details available in Customer Area: http://secunia.com/vulnerability_intelligence/
EXTENDED SOLUTION: Further details available in Customer Area: http://secunia.com/vulnerability_intelligence/
EXPLOIT: Further details available in Customer Area: http://secunia.com/vulnerability_intelligence/
About: This Advisory was delivered by Secunia as a free service to help private users keeping their systems up to date against the latest vulnerabilities.
Subscribe: http://secunia.com/advisories/secunia_security_advisories/
Definitions: (Criticality, Where etc.) http://secunia.com/advisories/about_secunia_advisories/
Please Note: Secunia recommends that you verify all advisories you receive by clicking the link. Secunia NEVER sends attached files with advisories. Secunia does not advise people to install third party patches, only use those supplied by the vendor.
Unsubscribe: Secunia Security Advisories http://secunia.com/sec_adv_unsubscribe/?email=packet%40packetstormsecurity.org
Show details on source website
{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-201209-0225",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "wincc",
"scope": "eq",
"trust": 1.6,
"vendor": "siemens",
"version": "7.0"
},
{
"model": "wincc",
"scope": "eq",
"trust": 1.6,
"vendor": "siemens",
"version": "5.0"
},
{
"model": "wincc",
"scope": "eq",
"trust": 1.6,
"vendor": "siemens",
"version": "6.0"
},
{
"model": "simatic pcs7",
"scope": "eq",
"trust": 1.6,
"vendor": "siemens",
"version": "8.0"
},
{
"model": "wincc",
"scope": "lte",
"trust": 1.0,
"vendor": "siemens",
"version": "7.0"
},
{
"model": null,
"scope": "eq",
"trust": 0.8,
"vendor": "wincc",
"version": "6.0"
},
{
"model": "simatic pcs 7",
"scope": null,
"trust": 0.8,
"vendor": "siemens",
"version": null
},
{
"model": "simatic wincc",
"scope": "lte",
"trust": 0.8,
"vendor": "siemens",
"version": "7.0 sp3"
},
{
"model": null,
"scope": "eq",
"trust": 0.6,
"vendor": "wincc",
"version": "7.0"
},
{
"model": "simatic wincc",
"scope": "eq",
"trust": 0.6,
"vendor": "siemens",
"version": "7.x"
},
{
"model": "simatic pcs",
"scope": "eq",
"trust": 0.6,
"vendor": "siemens",
"version": "77.x"
},
{
"model": null,
"scope": "eq",
"trust": 0.4,
"vendor": "wincc",
"version": "5.0"
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "simatic pcs7",
"version": "8.0"
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "wincc",
"version": "*"
}
],
"sources": [
{
"db": "IVD",
"id": "5e1894b4-2353-11e6-abef-000c29c66e3d"
},
{
"db": "CNVD",
"id": "CNVD-2012-5086"
},
{
"db": "JVNDB",
"id": "JVNDB-2012-004449"
},
{
"db": "NVD",
"id": "CVE-2012-3032"
},
{
"db": "CNNVD",
"id": "CNNVD-201209-295"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:a:siemens:simatic_pcs7:8.0:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:wincc:6.0:sp4:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:wincc:6.0:sp2:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:wincc:6.0:sp3:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:wincc:*:sp3:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "7.0",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:wincc:7.0:sp1:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:wincc:5.0:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:wincc:7.0:sp2:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:wincc:7.0:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:wincc:6.0:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:wincc:5.0:sp1:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2012-3032"
}
]
},
"credits": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/credits#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Denis Baranov Sergey Bobrov, Artem Chaykin, Vladimir Kochetkov, Pavel Toporkov,Timur Yunusov from Positive Technologies",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201209-295"
}
],
"trust": 0.6
},
"cve": "CVE-2012-3032",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"acInsufInfo": false,
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "NVD",
"availabilityImpact": "PARTIAL",
"baseScore": 7.5,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 10.0,
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "HIGH",
"trust": 1.0,
"userInteractionRequired": false,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
{
"acInsufInfo": null,
"accessComplexity": "Low",
"accessVector": "Network",
"authentication": "None",
"author": "NVD",
"availabilityImpact": "Partial",
"baseScore": 7.5,
"confidentialityImpact": "Partial",
"exploitabilityScore": null,
"id": "CVE-2012-3032",
"impactScore": null,
"integrityImpact": "Partial",
"obtainAllPrivilege": null,
"obtainOtherPrivilege": null,
"obtainUserPrivilege": null,
"severity": "High",
"trust": 0.8,
"userInteractionRequired": null,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "IVD",
"availabilityImpact": "PARTIAL",
"baseScore": 7.5,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 10.0,
"id": "5e1894b4-2353-11e6-abef-000c29c66e3d",
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"severity": "HIGH",
"trust": 0.2,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.9 [IVD]"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "VULHUB",
"availabilityImpact": "PARTIAL",
"baseScore": 7.5,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 10.0,
"id": "VHN-56313",
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"severity": "HIGH",
"trust": 0.1,
"vectorString": "AV:N/AC:L/AU:N/C:P/I:P/A:P",
"version": "2.0"
}
],
"cvssV3": [],
"severity": [
{
"author": "NVD",
"id": "CVE-2012-3032",
"trust": 1.8,
"value": "HIGH"
},
{
"author": "CNNVD",
"id": "CNNVD-201209-295",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "IVD",
"id": "5e1894b4-2353-11e6-abef-000c29c66e3d",
"trust": 0.2,
"value": "HIGH"
},
{
"author": "VULHUB",
"id": "VHN-56313",
"trust": 0.1,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "IVD",
"id": "5e1894b4-2353-11e6-abef-000c29c66e3d"
},
{
"db": "VULHUB",
"id": "VHN-56313"
},
{
"db": "JVNDB",
"id": "JVNDB-2012-004449"
},
{
"db": "NVD",
"id": "CVE-2012-3032"
},
{
"db": "CNNVD",
"id": "CNNVD-201209-295"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "SQL injection vulnerability in WebNavigator in Siemens WinCC 7.0 SP3 and earlier, as used in SIMATIC PCS7 and other products, allows remote attackers to execute arbitrary SQL commands via a crafted SOAP message. Siemens SIMATIC is an automation software in a single engineering environment. Siemens SIMATIC WinCC is prone to information-disclosure, SQL-injection, directory-traversal, and cross-site scripting vulnerabilities because it fails to sufficiently sanitize user-supplied input. \nThe attacker may exploit the information-disclosure issue and directory-traversal issues to gain access to sensitive information that may lead to further attacks. \nThe attacker may exploit the SQL-injection issue to compromise the application, access or modify data, or exploit latent vulnerabilities in the underlying database. \nAn attacker may leverage the cross-site scripting issue to execute arbitrary script code in the browser of an unsuspecting user in the context of the affected site. This may allow the attacker to steal cookie-based authentication credentials and to launch other attacks. \nSiemens SIMATIC WinCC 7.0 SP3 and prior versions are vulnerable. WinCC flexible is a human-machine interface used in some machine or process applications. \n\nThe application allows users to perform certain actions via HTTP\nrequests without performing proper validity checks to verify the\nrequests. This can be exploited to perform certain unspecified\nactions when a logged-in administrative user visits a specially\ncrafted web page. ----------------------------------------------------------------------\n\nThe final version of the CSI 6.0 has been released. \nFind out why this is not just another Patch Management solution: http://secunia.com/blog/325/\n\n----------------------------------------------------------------------\n\nTITLE:\nSiemens SIMATIC WinCC Multiple Vulnerabilities\n\nSECUNIA ADVISORY ID:\nSA50568\n\nVERIFY ADVISORY:\nSecunia.com\nhttp://secunia.com/advisories/50568/\nCustomer Area (Credentials Required)\nhttps://ca.secunia.com/?page=viewadvisory\u0026vuln_id=50568\n\nRELEASE DATE:\n2012-09-11\n\nDISCUSS ADVISORY:\nhttp://secunia.com/advisories/50568/#comments\n\nAVAILABLE ON SITE AND IN CUSTOMER AREA:\n * Last Update\n * Popularity\n * Comments\n * Criticality Level\n * Impact\n * Where\n * Solution Status\n * Operating System / Software\n * CVE Reference(s)\n\nhttp://secunia.com/advisories/50568/\n\nONLY AVAILABLE IN CUSTOMER AREA:\n * Authentication Level\n * Report Reliability\n * Secunia PoC\n * Secunia Analysis\n * Systems Affected\n * Approve Distribution\n * Remediation Status\n * Secunia CVSS Score\n * CVSS\n\nhttps://ca.secunia.com/?page=viewadvisory\u0026vuln_id=50568\n\nONLY AVAILABLE WITH SECUNIA CSI AND SECUNIA PSI:\n * AUTOMATED SCANNING\n\nhttp://secunia.com/vulnerability_scanning/personal/\nhttp://secunia.com/vulnerability_scanning/corporate/wsus_sccm_3rd_third_party_patching/\n\nDESCRIPTION:\nMultiple vulnerabilities have been reported in Siemens SIMATIC WinCC,\nwhich can be exploited by malicious people to conduct cross-site\nscripting attacks, conduct SQL injection attacks, and disclose\ncertain sensitive information. \n\n1) Certain unspecified input passed to the WebNavigator component is\nnot properly sanitised before being returned to the user. \n\n2) Certain input passed to the WebNavigator component is not properly\nverified before being used to read files. This can be exploited to\nread arbitrary files via directory traversal sequences. \nThis can be exploited to manipulate SQL queries by injecting arbitrary\nSQL code. \n\n4) An error within the ActiveX control can be exploited to disclose\nthe username and password of an authenticated user. \n\nSOLUTION:\nApply Update 3. \n\nFurther details available in Customer Area:\nhttp://secunia.com/vulnerability_intelligence/\n\nPROVIDED AND/OR DISCOVERED BY:\nThe vendor credits Denis Baranov, Sergey Bobrov, Artem Chaykin,\nVladimir Kochetkov, Pavel Toporkov, and Timur Yunusov, Positive\nTechnologies. \n\nORIGINAL ADVISORY:\nhttp://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-864051.pdf\n\nOTHER REFERENCES:\nFurther details available in Customer Area:\nhttp://secunia.com/vulnerability_intelligence/\n\nDEEP LINKS:\nFurther details available in Customer Area:\nhttp://secunia.com/vulnerability_intelligence/\n\nEXTENDED DESCRIPTION:\nFurther details available in Customer Area:\nhttp://secunia.com/vulnerability_intelligence/\n\nEXTENDED SOLUTION:\nFurther details available in Customer Area:\nhttp://secunia.com/vulnerability_intelligence/\n\nEXPLOIT:\nFurther details available in Customer Area:\nhttp://secunia.com/vulnerability_intelligence/\n\n----------------------------------------------------------------------\n\nAbout:\nThis Advisory was delivered by Secunia as a free service to help\nprivate users keeping their systems up to date against the latest\nvulnerabilities. \n\nSubscribe:\nhttp://secunia.com/advisories/secunia_security_advisories/\n\nDefinitions: (Criticality, Where etc.)\nhttp://secunia.com/advisories/about_secunia_advisories/\n\n\nPlease Note:\nSecunia recommends that you verify all advisories you receive by\nclicking the link. \nSecunia NEVER sends attached files with advisories. \nSecunia does not advise people to install third party patches, only\nuse those supplied by the vendor. \n\n----------------------------------------------------------------------\n\nUnsubscribe: Secunia Security Advisories\nhttp://secunia.com/sec_adv_unsubscribe/?email=packet%40packetstormsecurity.org\n\n----------------------------------------------------------------------\n\n\n",
"sources": [
{
"db": "NVD",
"id": "CVE-2012-3032"
},
{
"db": "JVNDB",
"id": "JVNDB-2012-004449"
},
{
"db": "CNVD",
"id": "CNVD-2012-5086"
},
{
"db": "BID",
"id": "55492"
},
{
"db": "IVD",
"id": "5e1894b4-2353-11e6-abef-000c29c66e3d"
},
{
"db": "VULHUB",
"id": "VHN-56313"
},
{
"db": "PACKETSTORM",
"id": "116445"
},
{
"db": "PACKETSTORM",
"id": "116447"
}
],
"trust": 2.88
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2012-3032",
"trust": 3.6
},
{
"db": "SIEMENS",
"id": "SSA-864051",
"trust": 2.5
},
{
"db": "ICS CERT",
"id": "ICSA-12-256-01",
"trust": 2.5
},
{
"db": "CNNVD",
"id": "CNNVD-201209-295",
"trust": 0.9
},
{
"db": "BID",
"id": "55492",
"trust": 0.9
},
{
"db": "CNVD",
"id": "CNVD-2012-5086",
"trust": 0.8
},
{
"db": "JVNDB",
"id": "JVNDB-2012-004449",
"trust": 0.8
},
{
"db": "SECUNIA",
"id": "50568",
"trust": 0.8
},
{
"db": "NSFOCUS",
"id": "20935",
"trust": 0.6
},
{
"db": "NSFOCUS",
"id": "20651",
"trust": 0.6
},
{
"db": "IVD",
"id": "5E1894B4-2353-11E6-ABEF-000C29C66E3D",
"trust": 0.2
},
{
"db": "SECUNIA",
"id": "50581",
"trust": 0.2
},
{
"db": "VULHUB",
"id": "VHN-56313",
"trust": 0.1
},
{
"db": "PACKETSTORM",
"id": "116445",
"trust": 0.1
},
{
"db": "PACKETSTORM",
"id": "116447",
"trust": 0.1
}
],
"sources": [
{
"db": "IVD",
"id": "5e1894b4-2353-11e6-abef-000c29c66e3d"
},
{
"db": "CNVD",
"id": "CNVD-2012-5086"
},
{
"db": "VULHUB",
"id": "VHN-56313"
},
{
"db": "BID",
"id": "55492"
},
{
"db": "JVNDB",
"id": "JVNDB-2012-004449"
},
{
"db": "PACKETSTORM",
"id": "116445"
},
{
"db": "PACKETSTORM",
"id": "116447"
},
{
"db": "NVD",
"id": "CVE-2012-3032"
},
{
"db": "CNNVD",
"id": "CNNVD-201209-295"
}
]
},
"id": "VAR-201209-0225",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "IVD",
"id": "5e1894b4-2353-11e6-abef-000c29c66e3d"
},
{
"db": "CNVD",
"id": "CNVD-2012-5086"
},
{
"db": "VULHUB",
"id": "VHN-56313"
}
],
"trust": 1.49052891
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"ICS"
],
"sub_category": null,
"trust": 0.8
}
],
"sources": [
{
"db": "IVD",
"id": "5e1894b4-2353-11e6-abef-000c29c66e3d"
},
{
"db": "CNVD",
"id": "CNVD-2012-5086"
}
]
},
"last_update_date": "2023-12-18T12:58:16.245000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Top Page",
"trust": 0.8,
"url": "http://www.siemens.com/"
},
{
"title": "SSA-864051: Multiple Vulnerabilities in WinCC 7.0 SP3",
"trust": 0.8,
"url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-864051.pdf"
},
{
"title": "\u30b7\u30fc\u30e1\u30f3\u30b9\u30bd\u30ea\u30e5\u30fc\u30b7\u30e7\u30f3\u30d1\u30fc\u30c8\u30ca\u30fc",
"trust": 0.8,
"url": "http://www.automation.siemens.com/automation/jp/ja/solutionpartner/pages/default.aspx"
},
{
"title": "\u30b7\u30fc\u30e1\u30f3\u30b9\u30fb\u30b8\u30e3\u30d1\u30f3\u682a\u5f0f\u4f1a\u793e",
"trust": 0.8,
"url": "http://www.siemens.com/entry/jp/ja/"
},
{
"title": "Patch for Siemens SIMATIC WinCC SOAP SQL Injection Vulnerability",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchinfo/show/22133"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2012-5086"
},
{
"db": "JVNDB",
"id": "JVNDB-2012-004449"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-89",
"trust": 1.9
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-56313"
},
{
"db": "JVNDB",
"id": "JVNDB-2012-004449"
},
{
"db": "NVD",
"id": "CVE-2012-3032"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.5,
"url": "http://www.us-cert.gov/control_systems/pdf/icsa-12-256-01.pdf"
},
{
"trust": 1.9,
"url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-864051.pdf"
},
{
"trust": 1.7,
"url": "http://en.securitylab.ru/lab/pt-2012-44"
},
{
"trust": 0.8,
"url": "http://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2012-3032"
},
{
"trust": 0.8,
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnid=cve-2012-3032"
},
{
"trust": 0.6,
"url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-864051.pdfhttp"
},
{
"trust": 0.6,
"url": "http://secunia.com/advisories/50568"
},
{
"trust": 0.6,
"url": "http://www.securityfocus.com/bid/55492"
},
{
"trust": 0.6,
"url": "http://www.nsfocus.net/vulndb/20935"
},
{
"trust": 0.6,
"url": "http://www.nsfocus.net/vulndb/20651"
},
{
"trust": 0.3,
"url": "http://aunz.siemens.com/newscentre/productreleases/pages/iac_pr_simaticwinccv62.aspx"
},
{
"trust": 0.2,
"url": "http://secunia.com/vulnerability_intelligence/"
},
{
"trust": 0.2,
"url": "http://secunia.com/advisories/secunia_security_advisories/"
},
{
"trust": 0.2,
"url": "http://secunia.com/vulnerability_scanning/corporate/wsus_sccm_3rd_third_party_patching/"
},
{
"trust": 0.2,
"url": "http://secunia.com/vulnerability_scanning/personal/"
},
{
"trust": 0.2,
"url": "http://secunia.com/sec_adv_unsubscribe/?email=packet%40packetstormsecurity.org"
},
{
"trust": 0.2,
"url": "http://secunia.com/blog/325/"
},
{
"trust": 0.2,
"url": "http://secunia.com/advisories/about_secunia_advisories/"
},
{
"trust": 0.1,
"url": "https://ca.secunia.com/?page=viewadvisory\u0026vuln_id=50581"
},
{
"trust": 0.1,
"url": "http://secunia.com/advisories/50581/#comments"
},
{
"trust": 0.1,
"url": "http://secunia.com/advisories/50581/"
},
{
"trust": 0.1,
"url": "http://secunia.com/advisories/50568/"
},
{
"trust": 0.1,
"url": "http://secunia.com/advisories/50568/#comments"
},
{
"trust": 0.1,
"url": "https://ca.secunia.com/?page=viewadvisory\u0026vuln_id=50568"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2012-5086"
},
{
"db": "VULHUB",
"id": "VHN-56313"
},
{
"db": "BID",
"id": "55492"
},
{
"db": "JVNDB",
"id": "JVNDB-2012-004449"
},
{
"db": "PACKETSTORM",
"id": "116445"
},
{
"db": "PACKETSTORM",
"id": "116447"
},
{
"db": "NVD",
"id": "CVE-2012-3032"
},
{
"db": "CNNVD",
"id": "CNNVD-201209-295"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "IVD",
"id": "5e1894b4-2353-11e6-abef-000c29c66e3d"
},
{
"db": "CNVD",
"id": "CNVD-2012-5086"
},
{
"db": "VULHUB",
"id": "VHN-56313"
},
{
"db": "BID",
"id": "55492"
},
{
"db": "JVNDB",
"id": "JVNDB-2012-004449"
},
{
"db": "PACKETSTORM",
"id": "116445"
},
{
"db": "PACKETSTORM",
"id": "116447"
},
{
"db": "NVD",
"id": "CVE-2012-3032"
},
{
"db": "CNNVD",
"id": "CNNVD-201209-295"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2012-09-13T00:00:00",
"db": "IVD",
"id": "5e1894b4-2353-11e6-abef-000c29c66e3d"
},
{
"date": "2012-09-13T00:00:00",
"db": "CNVD",
"id": "CNVD-2012-5086"
},
{
"date": "2012-09-18T00:00:00",
"db": "VULHUB",
"id": "VHN-56313"
},
{
"date": "2012-09-11T00:00:00",
"db": "BID",
"id": "55492"
},
{
"date": "2012-09-20T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2012-004449"
},
{
"date": "2012-09-11T07:30:00",
"db": "PACKETSTORM",
"id": "116445"
},
{
"date": "2012-09-11T07:30:06",
"db": "PACKETSTORM",
"id": "116447"
},
{
"date": "2012-09-18T14:55:01.537000",
"db": "NVD",
"id": "CVE-2012-3032"
},
{
"date": "2012-09-18T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201209-295"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2012-09-13T00:00:00",
"db": "CNVD",
"id": "CNVD-2012-5086"
},
{
"date": "2012-09-19T00:00:00",
"db": "VULHUB",
"id": "VHN-56313"
},
{
"date": "2012-09-12T22:50:00",
"db": "BID",
"id": "55492"
},
{
"date": "2012-09-20T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2012-004449"
},
{
"date": "2012-09-19T14:03:28.030000",
"db": "NVD",
"id": "CVE-2012-3032"
},
{
"date": "2012-09-20T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201209-295"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201209-295"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Siemens WinCC of WebNavigator In SQL Injection vulnerability",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2012-004449"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "SQL injection",
"sources": [
{
"db": "IVD",
"id": "5e1894b4-2353-11e6-abef-000c29c66e3d"
},
{
"db": "CNNVD",
"id": "CNNVD-201209-295"
}
],
"trust": 0.8
}
}
VAR-201711-1076
Vulnerability from variot - Updated: 2023-12-18 12:51An Improper Input Validation issue was discovered in Siemens SIMATIC PCS 7 V8.1 prior to V8.1 SP1 with WinCC V7.3 Upd 13, and V8.2 all versions. The improper input validation vulnerability has been identified, which may allow an authenticated remote attacker who is a member of the administrators group to crash services by sending specially crafted messages to the DCOM interface. SIMATIC PCS 7 is a set of distributed process control systems using WinCC from Siemens AG, Germany. Siemens SIMATIC PCS 7 is prone to a denial-of-service vulnerability. Remote attackers may exploit this issue to cause denial-of-service conditions, denying service to legitimate users
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-201711-1076",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "simatic pcs7",
"scope": "eq",
"trust": 1.9,
"vendor": "siemens",
"version": "8.2"
},
{
"model": "simatic pcs7",
"scope": "eq",
"trust": 1.3,
"vendor": "siemens",
"version": "8.1"
},
{
"model": "simatic wincc",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "7.3"
},
{
"model": "simatic pcs 7",
"scope": null,
"trust": 0.8,
"vendor": "siemens",
"version": null
},
{
"model": "simatic wincc",
"scope": null,
"trust": 0.8,
"vendor": "siemens",
"version": null
},
{
"model": "simatic pcs sp1",
"scope": "eq",
"trust": 0.6,
"vendor": "siemens",
"version": "7v8.1\u003cv8.1"
},
{
"model": "simatic pcs upd",
"scope": "eq",
"trust": 0.6,
"vendor": "siemens",
"version": "7v7.313"
},
{
"model": "simatic pcs",
"scope": "eq",
"trust": 0.6,
"vendor": "siemens",
"version": "7v8.2"
},
{
"model": "simatic wincc update",
"scope": "ne",
"trust": 0.3,
"vendor": "siemens",
"version": "7.313"
},
{
"model": "simatic pcs7 sp1",
"scope": "ne",
"trust": 0.3,
"vendor": "siemens",
"version": "8.1"
},
{
"model": "simatic pcs siemens simatic pcs upd 13siemens simatic pcs",
"scope": "eq",
"trust": 0.2,
"vendor": "siemens",
"version": "7v8.17v7.37v8.2"
}
],
"sources": [
{
"db": "IVD",
"id": "0fe3415c-af39-4c5b-a5d8-06ff8b01db12"
},
{
"db": "CNVD",
"id": "CNVD-2017-32563"
},
{
"db": "BID",
"id": "101680"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-009948"
},
{
"db": "NVD",
"id": "CVE-2017-14023"
},
{
"db": "CNNVD",
"id": "CNNVD-201708-1252"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:a:siemens:simatic_pcs7:8.1:-:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:simatic_wincc:7.3:update13:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:a:siemens:simatic_pcs7:8.2:-:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2017-14023"
}
]
},
"credits": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/credits#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Sergey Temnikov and Vladimir Dashchenko of Kaspersky Labs.",
"sources": [
{
"db": "BID",
"id": "101680"
}
],
"trust": 0.3
},
"cve": "CVE-2017-14023",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"acInsufInfo": false,
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"author": "NVD",
"availabilityImpact": "PARTIAL",
"baseScore": 4.0,
"confidentialityImpact": "NONE",
"exploitabilityScore": 8.0,
"impactScore": 2.9,
"integrityImpact": "NONE",
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "MEDIUM",
"trust": 1.0,
"userInteractionRequired": false,
"vectorString": "AV:N/AC:L/Au:S/C:N/I:N/A:P",
"version": "2.0"
},
{
"acInsufInfo": null,
"accessComplexity": "Low",
"accessVector": "Network",
"authentication": "Single",
"author": "NVD",
"availabilityImpact": "Partial",
"baseScore": 4.0,
"confidentialityImpact": "None",
"exploitabilityScore": null,
"id": "CVE-2017-14023",
"impactScore": null,
"integrityImpact": "None",
"obtainAllPrivilege": null,
"obtainOtherPrivilege": null,
"obtainUserPrivilege": null,
"severity": "Medium",
"trust": 0.8,
"userInteractionRequired": null,
"vectorString": "AV:N/AC:L/Au:S/C:N/I:N/A:P",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 7.8,
"confidentialityImpact": "NONE",
"exploitabilityScore": 10.0,
"id": "CNVD-2017-32563",
"impactScore": 6.9,
"integrityImpact": "NONE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "IVD",
"availabilityImpact": "COMPLETE",
"baseScore": 7.8,
"confidentialityImpact": "NONE",
"exploitabilityScore": 10.0,
"id": "0fe3415c-af39-4c5b-a5d8-06ff8b01db12",
"impactScore": 6.9,
"integrityImpact": "NONE",
"severity": "HIGH",
"trust": 0.2,
"vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
"version": "2.9 [IVD]"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"author": "VULHUB",
"availabilityImpact": "PARTIAL",
"baseScore": 4.0,
"confidentialityImpact": "NONE",
"exploitabilityScore": 8.0,
"id": "VHN-104704",
"impactScore": 2.9,
"integrityImpact": "NONE",
"severity": "MEDIUM",
"trust": 0.1,
"vectorString": "AV:N/AC:L/AU:S/C:N/I:N/A:P",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "NVD",
"availabilityImpact": "HIGH",
"baseScore": 4.9,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"exploitabilityScore": 1.2,
"impactScore": 3.6,
"integrityImpact": "NONE",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 4.9,
"baseSeverity": "Medium",
"confidentialityImpact": "None",
"exploitabilityScore": null,
"id": "CVE-2017-14023",
"impactScore": null,
"integrityImpact": "None",
"privilegesRequired": "High",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2017-14023",
"trust": 1.8,
"value": "MEDIUM"
},
{
"author": "CNVD",
"id": "CNVD-2017-32563",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "CNNVD",
"id": "CNNVD-201708-1252",
"trust": 0.6,
"value": "MEDIUM"
},
{
"author": "IVD",
"id": "0fe3415c-af39-4c5b-a5d8-06ff8b01db12",
"trust": 0.2,
"value": "MEDIUM"
},
{
"author": "VULHUB",
"id": "VHN-104704",
"trust": 0.1,
"value": "MEDIUM"
}
]
}
],
"sources": [
{
"db": "IVD",
"id": "0fe3415c-af39-4c5b-a5d8-06ff8b01db12"
},
{
"db": "CNVD",
"id": "CNVD-2017-32563"
},
{
"db": "VULHUB",
"id": "VHN-104704"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-009948"
},
{
"db": "NVD",
"id": "CVE-2017-14023"
},
{
"db": "CNNVD",
"id": "CNNVD-201708-1252"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "An Improper Input Validation issue was discovered in Siemens SIMATIC PCS 7 V8.1 prior to V8.1 SP1 with WinCC V7.3 Upd 13, and V8.2 all versions. The improper input validation vulnerability has been identified, which may allow an authenticated remote attacker who is a member of the administrators group to crash services by sending specially crafted messages to the DCOM interface. SIMATIC PCS 7 is a set of distributed process control systems using WinCC from Siemens AG, Germany. Siemens SIMATIC PCS 7 is prone to a denial-of-service vulnerability. \nRemote attackers may exploit this issue to cause denial-of-service conditions, denying service to legitimate users",
"sources": [
{
"db": "NVD",
"id": "CVE-2017-14023"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-009948"
},
{
"db": "CNVD",
"id": "CNVD-2017-32563"
},
{
"db": "BID",
"id": "101680"
},
{
"db": "IVD",
"id": "0fe3415c-af39-4c5b-a5d8-06ff8b01db12"
},
{
"db": "VULHUB",
"id": "VHN-104704"
}
],
"trust": 2.7
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2017-14023",
"trust": 3.6
},
{
"db": "ICS CERT",
"id": "ICSA-17-306-01",
"trust": 3.4
},
{
"db": "BID",
"id": "101680",
"trust": 2.0
},
{
"db": "SECTRACK",
"id": "1039729",
"trust": 1.7
},
{
"db": "CNNVD",
"id": "CNNVD-201708-1252",
"trust": 0.9
},
{
"db": "CNVD",
"id": "CNVD-2017-32563",
"trust": 0.8
},
{
"db": "JVNDB",
"id": "JVNDB-2017-009948",
"trust": 0.8
},
{
"db": "IVD",
"id": "0FE3415C-AF39-4C5B-A5D8-06FF8B01DB12",
"trust": 0.2
},
{
"db": "VULHUB",
"id": "VHN-104704",
"trust": 0.1
}
],
"sources": [
{
"db": "IVD",
"id": "0fe3415c-af39-4c5b-a5d8-06ff8b01db12"
},
{
"db": "CNVD",
"id": "CNVD-2017-32563"
},
{
"db": "VULHUB",
"id": "VHN-104704"
},
{
"db": "BID",
"id": "101680"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-009948"
},
{
"db": "NVD",
"id": "CVE-2017-14023"
},
{
"db": "CNNVD",
"id": "CNNVD-201708-1252"
}
]
},
"id": "VAR-201711-1076",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "IVD",
"id": "0fe3415c-af39-4c5b-a5d8-06ff8b01db12"
},
{
"db": "CNVD",
"id": "CNVD-2017-32563"
},
{
"db": "VULHUB",
"id": "VHN-104704"
}
],
"trust": 1.53529841
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"ICS"
],
"sub_category": null,
"trust": 0.8
}
],
"sources": [
{
"db": "IVD",
"id": "0fe3415c-af39-4c5b-a5d8-06ff8b01db12"
},
{
"db": "CNVD",
"id": "CNVD-2017-32563"
}
]
},
"last_update_date": "2023-12-18T12:51:13.250000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "SSA-523365",
"trust": 0.8,
"url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-523365.pdf"
},
{
"title": "Siemens SIMATIC PCS 7 patch for denial of service vulnerability",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchinfo/show/105313"
},
{
"title": "Siemens SIMATIC PCS Security vulnerabilities",
"trust": 0.6,
"url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=100013"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2017-32563"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-009948"
},
{
"db": "CNNVD",
"id": "CNNVD-201708-1252"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-20",
"trust": 1.9
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-104704"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-009948"
},
{
"db": "NVD",
"id": "CVE-2017-14023"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 3.4,
"url": "https://ics-cert.us-cert.gov/advisories/icsa-17-306-01"
},
{
"trust": 1.7,
"url": "http://www.securityfocus.com/bid/101680"
},
{
"trust": 1.7,
"url": "http://www.securitytracker.com/id/1039729"
},
{
"trust": 0.8,
"url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2017-14023"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2017-14023"
},
{
"trust": 0.3,
"url": "http://www.siemens.com/"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2017-32563"
},
{
"db": "VULHUB",
"id": "VHN-104704"
},
{
"db": "BID",
"id": "101680"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-009948"
},
{
"db": "NVD",
"id": "CVE-2017-14023"
},
{
"db": "CNNVD",
"id": "CNNVD-201708-1252"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "IVD",
"id": "0fe3415c-af39-4c5b-a5d8-06ff8b01db12"
},
{
"db": "CNVD",
"id": "CNVD-2017-32563"
},
{
"db": "VULHUB",
"id": "VHN-104704"
},
{
"db": "BID",
"id": "101680"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-009948"
},
{
"db": "NVD",
"id": "CVE-2017-14023"
},
{
"db": "CNNVD",
"id": "CNNVD-201708-1252"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2017-11-03T00:00:00",
"db": "IVD",
"id": "0fe3415c-af39-4c5b-a5d8-06ff8b01db12"
},
{
"date": "2017-11-03T00:00:00",
"db": "CNVD",
"id": "CNVD-2017-32563"
},
{
"date": "2017-11-06T00:00:00",
"db": "VULHUB",
"id": "VHN-104704"
},
{
"date": "2017-11-02T00:00:00",
"db": "BID",
"id": "101680"
},
{
"date": "2017-11-29T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2017-009948"
},
{
"date": "2017-11-06T22:29:00.270000",
"db": "NVD",
"id": "CVE-2017-14023"
},
{
"date": "2017-08-31T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201708-1252"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2017-11-03T00:00:00",
"db": "CNVD",
"id": "CNVD-2017-32563"
},
{
"date": "2021-11-15T00:00:00",
"db": "VULHUB",
"id": "VHN-104704"
},
{
"date": "2017-12-19T22:00:00",
"db": "BID",
"id": "101680"
},
{
"date": "2017-11-29T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2017-009948"
},
{
"date": "2021-11-15T19:49:09.827000",
"db": "NVD",
"id": "CVE-2017-14023"
},
{
"date": "2019-10-17T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201708-1252"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201708-1252"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Siemens SIMATIC PCS 7 Denial of service vulnerability",
"sources": [
{
"db": "IVD",
"id": "0fe3415c-af39-4c5b-a5d8-06ff8b01db12"
},
{
"db": "CNVD",
"id": "CNVD-2017-32563"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Input validation error",
"sources": [
{
"db": "IVD",
"id": "0fe3415c-af39-4c5b-a5d8-06ff8b01db12"
},
{
"db": "BID",
"id": "101680"
},
{
"db": "CNNVD",
"id": "CNNVD-201708-1252"
}
],
"trust": 1.1
}
}
VAR-201705-3974
Vulnerability from variot - Updated: 2023-12-18 12:51A vulnerability was discovered in Siemens SIMATIC WinCC (V7.3 before Upd 11 and V7.4 before SP1), SIMATIC WinCC Runtime Professional (V13 before SP2 and V14 before SP1), SIMATIC WinCC (TIA Portal) Professional (V13 before SP2 and V14 before SP1) that could allow an authenticated, remote attacker who is member of the "administrators" group to crash services by sending specially crafted messages to the DCOM interface. Siemens SIMATIC WinCC and SIMATIC WinCC Runtime Professional are industrial automation products from Siemens AG. SIMATIC WinCC is a monitoring and data acquisition (SCADA) system. SIMATIC WinCC Runtime Professional is the control and monitoring of the operator's visual runtime platform machines and equipment. Multiple SIMATIC WinCC Products are prone to a denial-of-service vulnerability. The following products are vulnerable: SIMATIC WinCC 7.3 versions prior to 7.3 Update 11 SIMATIC WinCC 7.4 versions prior to 7.4 SP1 SIMATIC WinCC Runtime Professional 13 versions prior to 13 SP2 SIMATIC WinCC Runtime Professional 14 versions prior to 14 SP1 SIMATIC WinCC (TIA Portal) Professional 13 versions prior to 13 SP2 SIMATIC WinCC (TIA Portal) Professional 14 versions prior to 14 SP1. Siemens SIMATIC WinCC, etc. Siemens SIMATIC WinCC is an automated data acquisition and monitoring (SCADA) system; SIMATIC PCS 7 is a distributed process control system using WinCC. Security vulnerabilities exist in several Siemens products
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-201705-3974",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "simatic wincc",
"scope": "eq",
"trust": 1.9,
"vendor": "siemens",
"version": "7.4"
},
{
"model": "simatic wincc",
"scope": "eq",
"trust": 1.9,
"vendor": "siemens",
"version": "7.3"
},
{
"model": "simatic wincc runtime",
"scope": "eq",
"trust": 1.6,
"vendor": "siemens",
"version": "13"
},
{
"model": "simatic wincc \\",
"scope": "eq",
"trust": 1.6,
"vendor": "siemens",
"version": "13"
},
{
"model": "simatic wincc runtime",
"scope": "eq",
"trust": 1.6,
"vendor": "siemens",
"version": "14"
},
{
"model": "simatic wincc \\",
"scope": "eq",
"trust": 1.6,
"vendor": "siemens",
"version": "14"
},
{
"model": "simatic wincc runtime professional",
"scope": "eq",
"trust": 0.8,
"vendor": "siemens",
"version": "14 sp1"
},
{
"model": "simatic wincc",
"scope": "lt",
"trust": 0.8,
"vendor": "siemens",
"version": "13"
},
{
"model": "simatic wincc",
"scope": "eq",
"trust": 0.8,
"vendor": "siemens",
"version": "7.3 update 11"
},
{
"model": "simatic wincc",
"scope": "eq",
"trust": 0.8,
"vendor": "siemens",
"version": "7.4 sp1"
},
{
"model": "simatic wincc",
"scope": "lt",
"trust": 0.8,
"vendor": "siemens",
"version": "7.3"
},
{
"model": "simatic wincc runtime professional",
"scope": "lt",
"trust": 0.8,
"vendor": "siemens",
"version": "13"
},
{
"model": "simatic wincc",
"scope": "eq",
"trust": 0.8,
"vendor": "siemens",
"version": "14 sp1"
},
{
"model": "simatic wincc runtime professional",
"scope": "eq",
"trust": 0.8,
"vendor": "siemens",
"version": "13 sp2"
},
{
"model": "simatic wincc",
"scope": "lt",
"trust": 0.8,
"vendor": "siemens",
"version": "7.4"
},
{
"model": "simatic wincc",
"scope": "lt",
"trust": 0.8,
"vendor": "siemens",
"version": "14"
},
{
"model": "simatic wincc",
"scope": "eq",
"trust": 0.8,
"vendor": "siemens",
"version": "13 sp2"
},
{
"model": "simatic wincc runtime professional",
"scope": "lt",
"trust": 0.8,
"vendor": "siemens",
"version": "14"
},
{
"model": "simatic wincc upd",
"scope": "lt",
"trust": 0.6,
"vendor": "siemens",
"version": "v7.311"
},
{
"model": "simatic wincc sp1",
"scope": "lt",
"trust": 0.6,
"vendor": "siemens",
"version": "v7.4"
},
{
"model": "simatic wincc runtime professional sp2",
"scope": "lt",
"trust": 0.6,
"vendor": "siemens",
"version": "v13"
},
{
"model": "simatic wincc runtime professional sp1",
"scope": "lt",
"trust": 0.6,
"vendor": "siemens",
"version": "v14"
},
{
"model": "simatic wincc professional sp2",
"scope": "lt",
"trust": 0.6,
"vendor": "siemens",
"version": "v13"
},
{
"model": "simatic wincc professional sp1",
"scope": "lt",
"trust": 0.6,
"vendor": "siemens",
"version": "v14"
},
{
"model": "simatic wincc runtime professional",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "14"
},
{
"model": "simatic wincc runtime professional",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "13"
},
{
"model": "simatic wincc professional",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "14"
},
{
"model": "simatic wincc professional",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "13"
},
{
"model": "simatic wincc update",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "7.32"
},
{
"model": "simatic wincc update",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "7.310"
},
{
"model": "simatic wincc update",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "7.31"
},
{
"model": "simatic wincc runtime professional sp1",
"scope": "ne",
"trust": 0.3,
"vendor": "siemens",
"version": "14"
},
{
"model": "simatic wincc runtime professional sp2",
"scope": "ne",
"trust": 0.3,
"vendor": "siemens",
"version": "13"
},
{
"model": "simatic wincc professional sp1",
"scope": "ne",
"trust": 0.3,
"vendor": "siemens",
"version": "14"
},
{
"model": "simatic wincc professional sp2",
"scope": "ne",
"trust": 0.3,
"vendor": "siemens",
"version": "13"
},
{
"model": "simatic wincc sp1",
"scope": "ne",
"trust": 0.3,
"vendor": "siemens",
"version": "7.4"
},
{
"model": "simatic wincc update",
"scope": "ne",
"trust": 0.3,
"vendor": "siemens",
"version": "7.311"
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "simatic wincc",
"version": "7.3"
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "simatic wincc",
"version": "7.4"
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "simatic wincc tia portal",
"version": "13"
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "simatic wincc tia portal",
"version": "14"
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "simatic wincc runtime",
"version": "13"
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "simatic wincc runtime",
"version": "14"
}
],
"sources": [
{
"db": "IVD",
"id": "81c5d14f-8537-4b60-aa16-b99aec0c6e39"
},
{
"db": "CNVD",
"id": "CNVD-2017-06154"
},
{
"db": "BID",
"id": "98368"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-004058"
},
{
"db": "NVD",
"id": "CVE-2017-6867"
},
{
"db": "CNNVD",
"id": "CNNVD-201703-630"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:a:siemens:simatic_wincc_\\(tia_portal\\):14:*:*:*:professional:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:simatic_wincc_\\(tia_portal\\):13:sp1:*:*:professional:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:simatic_wincc_runtime:14:*:*:*:professional:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:simatic_wincc_runtime:13:sp1:*:*:professional:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:simatic_wincc:7.4:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:simatic_wincc:7.3:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2017-6867"
}
]
},
"credits": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/credits#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Sergey Temnikov and Vladimir Dashchenko of the Kaspersky Lab Critical Infrastructure Defense Team",
"sources": [
{
"db": "BID",
"id": "98368"
}
],
"trust": 0.3
},
"cve": "CVE-2017-6867",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"acInsufInfo": false,
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"author": "NVD",
"availabilityImpact": "PARTIAL",
"baseScore": 4.0,
"confidentialityImpact": "NONE",
"exploitabilityScore": 8.0,
"impactScore": 2.9,
"integrityImpact": "NONE",
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "MEDIUM",
"trust": 1.0,
"userInteractionRequired": false,
"vectorString": "AV:N/AC:L/Au:S/C:N/I:N/A:P",
"version": "2.0"
},
{
"acInsufInfo": null,
"accessComplexity": "Low",
"accessVector": "Network",
"authentication": "Single",
"author": "NVD",
"availabilityImpact": "Partial",
"baseScore": 4.0,
"confidentialityImpact": "None",
"exploitabilityScore": null,
"id": "CVE-2017-6867",
"impactScore": null,
"integrityImpact": "None",
"obtainAllPrivilege": null,
"obtainOtherPrivilege": null,
"obtainUserPrivilege": null,
"severity": "Medium",
"trust": 0.8,
"userInteractionRequired": null,
"vectorString": "AV:N/AC:L/Au:S/C:N/I:N/A:P",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 7.8,
"confidentialityImpact": "NONE",
"exploitabilityScore": 10.0,
"id": "CNVD-2017-06154",
"impactScore": 6.9,
"integrityImpact": "NONE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "IVD",
"availabilityImpact": "COMPLETE",
"baseScore": 7.8,
"confidentialityImpact": "NONE",
"exploitabilityScore": 10.0,
"id": "81c5d14f-8537-4b60-aa16-b99aec0c6e39",
"impactScore": 6.9,
"integrityImpact": "NONE",
"severity": "HIGH",
"trust": 0.2,
"vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
"version": "2.9 [IVD]"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"author": "VULHUB",
"availabilityImpact": "PARTIAL",
"baseScore": 4.0,
"confidentialityImpact": "NONE",
"exploitabilityScore": 8.0,
"id": "VHN-115070",
"impactScore": 2.9,
"integrityImpact": "NONE",
"severity": "MEDIUM",
"trust": 0.1,
"vectorString": "AV:N/AC:L/AU:S/C:N/I:N/A:P",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "NVD",
"availabilityImpact": "HIGH",
"baseScore": 4.9,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"exploitabilityScore": 1.2,
"impactScore": 3.6,
"integrityImpact": "NONE",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:H",
"version": "3.0"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 4.9,
"baseSeverity": "Medium",
"confidentialityImpact": "None",
"exploitabilityScore": null,
"id": "CVE-2017-6867",
"impactScore": null,
"integrityImpact": "None",
"privilegesRequired": "High",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2017-6867",
"trust": 1.8,
"value": "MEDIUM"
},
{
"author": "CNVD",
"id": "CNVD-2017-06154",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "CNNVD",
"id": "CNNVD-201703-630",
"trust": 0.6,
"value": "MEDIUM"
},
{
"author": "IVD",
"id": "81c5d14f-8537-4b60-aa16-b99aec0c6e39",
"trust": 0.2,
"value": "MEDIUM"
},
{
"author": "VULHUB",
"id": "VHN-115070",
"trust": 0.1,
"value": "MEDIUM"
}
]
}
],
"sources": [
{
"db": "IVD",
"id": "81c5d14f-8537-4b60-aa16-b99aec0c6e39"
},
{
"db": "CNVD",
"id": "CNVD-2017-06154"
},
{
"db": "VULHUB",
"id": "VHN-115070"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-004058"
},
{
"db": "NVD",
"id": "CVE-2017-6867"
},
{
"db": "CNNVD",
"id": "CNNVD-201703-630"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "A vulnerability was discovered in Siemens SIMATIC WinCC (V7.3 before Upd 11 and V7.4 before SP1), SIMATIC WinCC Runtime Professional (V13 before SP2 and V14 before SP1), SIMATIC WinCC (TIA Portal) Professional (V13 before SP2 and V14 before SP1) that could allow an authenticated, remote attacker who is member of the \"administrators\" group to crash services by sending specially crafted messages to the DCOM interface. Siemens SIMATIC WinCC and SIMATIC WinCC Runtime Professional are industrial automation products from Siemens AG. SIMATIC WinCC is a monitoring and data acquisition (SCADA) system. SIMATIC WinCC Runtime Professional is the control and monitoring of the operator\u0027s visual runtime platform machines and equipment. Multiple SIMATIC WinCC Products are prone to a denial-of-service vulnerability. \nThe following products are vulnerable:\nSIMATIC WinCC 7.3 versions prior to 7.3 Update 11\nSIMATIC WinCC 7.4 versions prior to 7.4 SP1\nSIMATIC WinCC Runtime Professional 13 versions prior to 13 SP2\nSIMATIC WinCC Runtime Professional 14 versions prior to 14 SP1\nSIMATIC WinCC (TIA Portal) Professional 13 versions prior to 13 SP2\nSIMATIC WinCC (TIA Portal) Professional 14 versions prior to 14 SP1. Siemens SIMATIC WinCC, etc. Siemens SIMATIC WinCC is an automated data acquisition and monitoring (SCADA) system; SIMATIC PCS 7 is a distributed process control system using WinCC. Security vulnerabilities exist in several Siemens products",
"sources": [
{
"db": "NVD",
"id": "CVE-2017-6867"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-004058"
},
{
"db": "CNVD",
"id": "CNVD-2017-06154"
},
{
"db": "BID",
"id": "98368"
},
{
"db": "IVD",
"id": "81c5d14f-8537-4b60-aa16-b99aec0c6e39"
},
{
"db": "VULHUB",
"id": "VHN-115070"
}
],
"trust": 2.7
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2017-6867",
"trust": 3.6
},
{
"db": "SIEMENS",
"id": "SSA-156872",
"trust": 2.3
},
{
"db": "BID",
"id": "98368",
"trust": 2.0
},
{
"db": "SIEMENS",
"id": "SSA-523365",
"trust": 1.1
},
{
"db": "CNNVD",
"id": "CNNVD-201703-630",
"trust": 0.9
},
{
"db": "CNVD",
"id": "CNVD-2017-06154",
"trust": 0.8
},
{
"db": "ICS CERT",
"id": "ICSA-17-306-01",
"trust": 0.8
},
{
"db": "JVNDB",
"id": "JVNDB-2017-004058",
"trust": 0.8
},
{
"db": "ICS CERT",
"id": "ICSA-17-129-03",
"trust": 0.3
},
{
"db": "IVD",
"id": "81C5D14F-8537-4B60-AA16-B99AEC0C6E39",
"trust": 0.2
},
{
"db": "VULHUB",
"id": "VHN-115070",
"trust": 0.1
}
],
"sources": [
{
"db": "IVD",
"id": "81c5d14f-8537-4b60-aa16-b99aec0c6e39"
},
{
"db": "CNVD",
"id": "CNVD-2017-06154"
},
{
"db": "VULHUB",
"id": "VHN-115070"
},
{
"db": "BID",
"id": "98368"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-004058"
},
{
"db": "NVD",
"id": "CVE-2017-6867"
},
{
"db": "CNNVD",
"id": "CNNVD-201703-630"
}
]
},
"id": "VAR-201705-3974",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "IVD",
"id": "81c5d14f-8537-4b60-aa16-b99aec0c6e39"
},
{
"db": "CNVD",
"id": "CNVD-2017-06154"
},
{
"db": "VULHUB",
"id": "VHN-115070"
}
],
"trust": 1.561624812
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"ICS"
],
"sub_category": null,
"trust": 0.8
}
],
"sources": [
{
"db": "IVD",
"id": "81c5d14f-8537-4b60-aa16-b99aec0c6e39"
},
{
"db": "CNVD",
"id": "CNVD-2017-06154"
}
]
},
"last_update_date": "2023-12-18T12:51:13.289000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "SSA-156872",
"trust": 0.8,
"url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-156872.pdf"
},
{
"title": "Patch for Siemens SIMATIC WinCC and SIMATIC WinCC Runtime Professional Denial of Service Vulnerability",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchinfo/show/176383"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2017-06154"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-004058"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-20",
"trust": 1.9
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-115070"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-004058"
},
{
"db": "NVD",
"id": "CVE-2017-6867"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.3,
"url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-156872.pdf"
},
{
"trust": 1.7,
"url": "http://www.securityfocus.com/bid/98368"
},
{
"trust": 1.1,
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-523365.pdf"
},
{
"trust": 0.8,
"url": "http://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2017-6867"
},
{
"trust": 0.8,
"url": "https://ics-cert.us-cert.gov/advisories/icsa-17-306-01"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2017-6867"
},
{
"trust": 0.6,
"url": "http://www.siemens.com/cert/en/cert-security-advisories.htm"
},
{
"trust": 0.3,
"url": "http://www.siemens.com/"
},
{
"trust": 0.3,
"url": "https://ics-cert.us-cert.gov/advisories/icsa-17-129-03"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2017-06154"
},
{
"db": "VULHUB",
"id": "VHN-115070"
},
{
"db": "BID",
"id": "98368"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-004058"
},
{
"db": "NVD",
"id": "CVE-2017-6867"
},
{
"db": "CNNVD",
"id": "CNNVD-201703-630"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "IVD",
"id": "81c5d14f-8537-4b60-aa16-b99aec0c6e39"
},
{
"db": "CNVD",
"id": "CNVD-2017-06154"
},
{
"db": "VULHUB",
"id": "VHN-115070"
},
{
"db": "BID",
"id": "98368"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-004058"
},
{
"db": "NVD",
"id": "CVE-2017-6867"
},
{
"db": "CNNVD",
"id": "CNNVD-201703-630"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2017-05-09T00:00:00",
"db": "IVD",
"id": "81c5d14f-8537-4b60-aa16-b99aec0c6e39"
},
{
"date": "2017-05-09T00:00:00",
"db": "CNVD",
"id": "CNVD-2017-06154"
},
{
"date": "2017-05-11T00:00:00",
"db": "VULHUB",
"id": "VHN-115070"
},
{
"date": "2017-05-09T00:00:00",
"db": "BID",
"id": "98368"
},
{
"date": "2017-06-15T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2017-004058"
},
{
"date": "2017-05-11T10:29:00.260000",
"db": "NVD",
"id": "CVE-2017-6867"
},
{
"date": "2017-03-16T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201703-630"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2019-08-22T00:00:00",
"db": "CNVD",
"id": "CNVD-2017-06154"
},
{
"date": "2018-06-14T00:00:00",
"db": "VULHUB",
"id": "VHN-115070"
},
{
"date": "2017-05-23T16:23:00",
"db": "BID",
"id": "98368"
},
{
"date": "2018-06-13T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2017-004058"
},
{
"date": "2018-06-14T01:29:31.133000",
"db": "NVD",
"id": "CVE-2017-6867"
},
{
"date": "2017-05-31T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201703-630"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201703-630"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "plural Siemens SIMATIC Vulnerability that can crash services in products",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2017-004058"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Input validation",
"sources": [
{
"db": "IVD",
"id": "81c5d14f-8537-4b60-aa16-b99aec0c6e39"
},
{
"db": "CNNVD",
"id": "CNNVD-201703-630"
}
],
"trust": 0.8
}
}
VAR-201705-3973
Vulnerability from variot - Updated: 2023-12-18 12:44A vulnerability has been identified in Primary Setup Tool (PST) (All versions < V4.2 HF1), SIMATIC Automation Tool (All versions < V3.0), SIMATIC NET PC-Software (All versions < V14 SP1), SIMATIC PCS 7 V8.1 (All versions), SIMATIC PCS 7 V8.2 (All versions < V8.2 SP1), SIMATIC STEP 7 (TIA Portal) V13 (All versions < V13 SP2), SIMATIC STEP 7 (TIA Portal) V14 (All versions < V14 SP1), SIMATIC STEP 7 V5.X (All versions < V5.6), SIMATIC WinAC RTX 2010 SP2 (All versions), SIMATIC WinAC RTX F 2010 SP2 (All versions), SIMATIC WinCC (TIA Portal) V13 (All versions < V13 SP2), SIMATIC WinCC (TIA Portal) V14 (All versions < V14 SP1), SIMATIC WinCC V7.2 and prior (All versions), SIMATIC WinCC V7.3 (All versions < V7.3 Update 15), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Upd1), SIMATIC WinCC flexible 2008 (All versions < flexible 2008 SP5), SINAUT ST7CC (All versions installed in conjunction with SIMATIC WinCC < V7.3 Update 15), SINEMA Server (All versions < V14), SINUMERIK 808D Programming Tool (All versions < V4.7 SP4 HF2), SMART PC Access (All versions < V2.3), STEP 7 - Micro/WIN SMART (All versions < V2.3), Security Configuration Tool (SCT) (All versions < V5.0). Specially crafted PROFINET DCP broadcast packets sent to the affected products on a local Ethernet segment (Layer 2) could cause a Denial-of-Service condition of some services. The services require manual restart to recover. SIMATIC WinCC (TIA Portal), SIMATIC STEP 7, SMART PC Access, SIMATIC Automation Tool, etc. are all industrial automation products from Siemens AG. A number of Siemens industrial products have a denial of service vulnerability. Attackers can exploit this issue to crash the affected device, denying service to legitimate users. Siemens SIMATIC WinCC, etc. Siemens SIMATIC WinCC is an automated data acquisition and monitoring (SCADA) system; SIMATIC PCS 7 is a distributed process control system using WinCC
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-201705-3973",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "smart pc access",
"scope": "eq",
"trust": 2.5,
"vendor": "siemens",
"version": "2.0"
},
{
"model": "simatic wincc",
"scope": null,
"trust": 1.6,
"vendor": "siemens",
"version": null
},
{
"model": "sinema server",
"scope": "eq",
"trust": 1.6,
"vendor": "siemens",
"version": null
},
{
"model": "simatic wincc",
"scope": "eq",
"trust": 1.6,
"vendor": "siemens",
"version": null
},
{
"model": "simatic step 7 micro\\/win smart",
"scope": "eq",
"trust": 1.6,
"vendor": "siemens",
"version": null
},
{
"model": "sinumerik 808d programming tool",
"scope": "eq",
"trust": 1.6,
"vendor": "siemens",
"version": null
},
{
"model": "simatic wincc flexible 2008",
"scope": "eq",
"trust": 1.6,
"vendor": "siemens",
"version": null
},
{
"model": "sinaut st7cc",
"scope": "eq",
"trust": 1.6,
"vendor": "siemens",
"version": null
},
{
"model": "simatic wincc \\",
"scope": "eq",
"trust": 1.6,
"vendor": "siemens",
"version": "13.0"
},
{
"model": "simatic winac rtx 2010",
"scope": "eq",
"trust": 1.6,
"vendor": "siemens",
"version": null
},
{
"model": "simatic wincc \\",
"scope": "eq",
"trust": 1.6,
"vendor": "siemens",
"version": "14.0"
},
{
"model": "simatic automation tool",
"scope": null,
"trust": 1.4,
"vendor": "siemens",
"version": null
},
{
"model": "sinaut st7cc",
"scope": null,
"trust": 1.4,
"vendor": "siemens",
"version": null
},
{
"model": "sinumerik 808d programming tool",
"scope": null,
"trust": 1.4,
"vendor": "siemens",
"version": null
},
{
"model": "simatic step 7 \\",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "13.0"
},
{
"model": "simatic automation tool",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "simatic step 7 \\",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "14.0"
},
{
"model": "simatic winac rtx f 2010",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "simatic net pc-software",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "simatic step 7 \\",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "5.0"
},
{
"model": "pcs 7",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "primary setup tool",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "security configuration tool",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": null
},
{
"model": "simatic wincc flexible",
"scope": "eq",
"trust": 0.9,
"vendor": "siemens",
"version": "2008"
},
{
"model": "simatic wincc",
"scope": "eq",
"trust": 0.9,
"vendor": "siemens",
"version": "0"
},
{
"model": "primary setup tool",
"scope": null,
"trust": 0.8,
"vendor": "siemens",
"version": null
},
{
"model": "security configuration tool",
"scope": null,
"trust": 0.8,
"vendor": "siemens",
"version": null
},
{
"model": "simatic net pc software",
"scope": null,
"trust": 0.8,
"vendor": "siemens",
"version": null
},
{
"model": "simatic pcs 7",
"scope": null,
"trust": 0.8,
"vendor": "siemens",
"version": null
},
{
"model": "simatic step 7",
"scope": "eq",
"trust": 0.8,
"vendor": "siemens",
"version": "v5.x"
},
{
"model": "simatic step 7",
"scope": null,
"trust": 0.8,
"vendor": "siemens",
"version": null
},
{
"model": "simatic winac rtx 2010",
"scope": null,
"trust": 0.8,
"vendor": "siemens",
"version": null
},
{
"model": "simatic winac rtx f 2010",
"scope": null,
"trust": 0.8,
"vendor": "siemens",
"version": null
},
{
"model": "simatic wincc flexible 2008",
"scope": null,
"trust": 0.8,
"vendor": "siemens",
"version": null
},
{
"model": "sinema server",
"scope": null,
"trust": 0.8,
"vendor": "siemens",
"version": null
},
{
"model": "smart pc access",
"scope": null,
"trust": 0.8,
"vendor": "siemens",
"version": null
},
{
"model": "step 7 - micro/win smart",
"scope": null,
"trust": 0.8,
"vendor": "siemens",
"version": null
},
{
"model": "simatic step",
"scope": "eq",
"trust": 0.6,
"vendor": "siemens",
"version": "75.x"
},
{
"model": "simatic winac rtx sp2 all",
"scope": "eq",
"trust": 0.6,
"vendor": "siemens",
"version": "2010"
},
{
"model": "simatic winac rtx f sp2 all",
"scope": "eq",
"trust": 0.6,
"vendor": "siemens",
"version": "2010"
},
{
"model": "security configuration tool all",
"scope": null,
"trust": 0.6,
"vendor": "siemens",
"version": null
},
{
"model": "primary setup tool all",
"scope": null,
"trust": 0.6,
"vendor": "siemens",
"version": null
},
{
"model": "simatic pcs",
"scope": "eq",
"trust": 0.6,
"vendor": "siemens",
"version": "7"
},
{
"model": "simatic wincc professional sp2",
"scope": "lt",
"trust": 0.6,
"vendor": "siemens",
"version": "v13"
},
{
"model": "simatic wincc professional sp1",
"scope": "lt",
"trust": 0.6,
"vendor": "siemens",
"version": "v14"
},
{
"model": "simatic step sp2",
"scope": "eq",
"trust": 0.6,
"vendor": "siemens",
"version": "7\u003cv13"
},
{
"model": "simatic step sp1",
"scope": "eq",
"trust": 0.6,
"vendor": "siemens",
"version": "7\u003cv14"
},
{
"model": "step micro win smart",
"scope": "eq",
"trust": 0.6,
"vendor": "siemens",
"version": "7-/"
},
{
"model": "simatic net pc-software",
"scope": null,
"trust": 0.6,
"vendor": "siemens",
"version": null
},
{
"model": "sinumerik 808d programming tool",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "0"
},
{
"model": "sinema server sp2",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "13"
},
{
"model": "sinema server sp1",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "12.0"
},
{
"model": "sinema server",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "12.0-"
},
{
"model": "sinema server",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "0"
},
{
"model": "sinaut st7cc",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "0"
},
{
"model": "simatic wincc flexible sp3 up7",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "2008"
},
{
"model": "simatic wincc flexible sp2",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "2008"
},
{
"model": "simatic wincc flexible sp1",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "2008"
},
{
"model": "simatic wincc basic",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "14"
},
{
"model": "simatic wincc sp1",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "v13"
},
{
"model": "simatic wincc",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "v13"
},
{
"model": "simatic winac rtx f sp2",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "2010"
},
{
"model": "simatic winac rtx sp2",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "2010"
},
{
"model": "simatic step tia portal",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "7v14"
},
{
"model": "simatic step tia portal sp1",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "7v13"
},
{
"model": "simatic step tia portal",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "7v13"
},
{
"model": "simatic step sp4 hf4",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "75.5"
},
{
"model": "simatic step sp4",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "75.5"
},
{
"model": "simatic step sp3 hf10",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "75.5"
},
{
"model": "simatic step sp3",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "75.5"
},
{
"model": "simatic step sp2 hf7",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "75.5"
},
{
"model": "simatic step sp2",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "75.5"
},
{
"model": "simatic step sp1 hf2",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "75.5"
},
{
"model": "simatic step sp1",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "75.5"
},
{
"model": "simatic pcs sp4",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "77.1"
},
{
"model": "simatic pcs",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "77.1"
},
{
"model": "simatic pcs",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "77"
},
{
"model": "simatic net pc-software",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "14"
},
{
"model": "simatic net pc-software sp2",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "13"
},
{
"model": "simatic net pc-software hf1",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "13"
},
{
"model": "simatic net pc-software",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "13"
},
{
"model": "simatic net pc-software sp2 hf3",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "12"
},
{
"model": "simatic net pc-software",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "12"
},
{
"model": "simatic automation tool",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "1.0.2"
},
{
"model": "simatic automation tool",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "1.0"
},
{
"model": "security configuration tool",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "0"
},
{
"model": "primary setup tool",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "0"
},
{
"model": "micro/win",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "0"
},
{
"model": "simatic wincc sp1",
"scope": "ne",
"trust": 0.3,
"vendor": "siemens",
"version": "14"
},
{
"model": "simatic wincc sp2",
"scope": "ne",
"trust": 0.3,
"vendor": "siemens",
"version": "13"
},
{
"model": "simatic step tia portal sp1",
"scope": "ne",
"trust": 0.3,
"vendor": "siemens",
"version": "714"
},
{
"model": "simatic step tia portal sp2",
"scope": "ne",
"trust": 0.3,
"vendor": "siemens",
"version": "713"
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "pcs 7",
"version": null
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "primary setup tool",
"version": null
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "security configuration tool",
"version": null
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "simatic automation tool",
"version": null
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "simatic net pc",
"version": null
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "simatic step 7 tia portal",
"version": "5.0"
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "simatic step 7 tia portal",
"version": "13.0"
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "simatic step 7 tia portal",
"version": "14.0"
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "simatic step 7 micro win smart",
"version": null
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "simatic winac rtx 2010",
"version": null
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "simatic winac rtx f 2010",
"version": null
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "simatic wincc",
"version": null
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "simatic wincc tia portal",
"version": "13.0"
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "simatic wincc tia portal",
"version": "14.0"
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "simatic wincc flexible 2008",
"version": null
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "sinaut st7cc",
"version": null
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "sinema server",
"version": null
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "sinumerik 808d programming tool",
"version": null
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "smart pc access",
"version": "2.0"
}
],
"sources": [
{
"db": "IVD",
"id": "1b7b75ad-c1f6-4e73-be28-ff3e458e7677"
},
{
"db": "CNVD",
"id": "CNVD-2017-06152"
},
{
"db": "BID",
"id": "98366"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-004136"
},
{
"db": "NVD",
"id": "CVE-2017-6865"
},
{
"db": "CNNVD",
"id": "CNNVD-201703-632"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:a:siemens:simatic_wincc_flexible_2008:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:simatic_net_pc-software:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:pcs_7:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:simatic_step_7_\\(tia_portal\\):14.0:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:simatic_wincc_\\(tia_portal\\):13.0:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:security_configuration_tool:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:primary_setup_tool:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:simatic_step_7_\\(tia_portal\\):5.0:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:simatic_step_7_\\(tia_portal\\):13.0:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:simatic_winac_rtx_2010:-:sp2:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:sinaut_st7cc:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:sinema_server:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:smart_pc_access:2.0:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:simatic_step_7_micro\\/win_smart:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:sinumerik_808d_programming_tool:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:simatic_winac_rtx_f_2010:-:sp2:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:simatic_wincc:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:simatic_automation_tool:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:simatic_wincc_\\(tia_portal\\):14.0:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2017-6865"
}
]
},
"credits": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/credits#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Duan JinTong, Ma ShaoShuai, and Cheng Lei from NSFOCUS Security Team.",
"sources": [
{
"db": "BID",
"id": "98366"
}
],
"trust": 0.3
},
"cve": "CVE-2017-6865",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"acInsufInfo": false,
"accessComplexity": "LOW",
"accessVector": "ADJACENT_NETWORK",
"authentication": "NONE",
"author": "NVD",
"availabilityImpact": "COMPLETE",
"baseScore": 6.1,
"confidentialityImpact": "NONE",
"exploitabilityScore": 6.5,
"impactScore": 6.9,
"integrityImpact": "NONE",
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "MEDIUM",
"trust": 1.0,
"userInteractionRequired": false,
"vectorString": "AV:A/AC:L/Au:N/C:N/I:N/A:C",
"version": "2.0"
},
{
"acInsufInfo": null,
"accessComplexity": "Low",
"accessVector": "Adjacent Network",
"authentication": "None",
"author": "NVD",
"availabilityImpact": "Complete",
"baseScore": 6.1,
"confidentialityImpact": "None",
"exploitabilityScore": null,
"id": "CVE-2017-6865",
"impactScore": null,
"integrityImpact": "None",
"obtainAllPrivilege": null,
"obtainOtherPrivilege": null,
"obtainUserPrivilege": null,
"severity": "Medium",
"trust": 0.8,
"userInteractionRequired": null,
"vectorString": "AV:A/AC:L/Au:N/C:N/I:N/A:C",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "ADJACENT_NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 6.1,
"confidentialityImpact": "NONE",
"exploitabilityScore": 6.5,
"id": "CNVD-2017-06152",
"impactScore": 6.9,
"integrityImpact": "NONE",
"severity": "MEDIUM",
"trust": 0.6,
"vectorString": "AV:A/AC:L/Au:N/C:N/I:N/A:C",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "ADJACENT_NETWORK",
"authentication": "NONE",
"author": "IVD",
"availabilityImpact": "COMPLETE",
"baseScore": 6.1,
"confidentialityImpact": "NONE",
"exploitabilityScore": 6.5,
"id": "1b7b75ad-c1f6-4e73-be28-ff3e458e7677",
"impactScore": 6.9,
"integrityImpact": "NONE",
"severity": "MEDIUM",
"trust": 0.2,
"vectorString": "AV:A/AC:L/Au:N/C:N/I:N/A:C",
"version": "2.9 [IVD]"
},
{
"accessComplexity": "LOW",
"accessVector": "ADJACENT_NETWORK",
"authentication": "NONE",
"author": "VULHUB",
"availabilityImpact": "COMPLETE",
"baseScore": 6.1,
"confidentialityImpact": "NONE",
"exploitabilityScore": 6.5,
"id": "VHN-115068",
"impactScore": 6.9,
"integrityImpact": "NONE",
"severity": "MEDIUM",
"trust": 0.1,
"vectorString": "AV:A/AC:L/AU:N/C:N/I:N/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"author": "NVD",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"exploitabilityScore": 2.8,
"impactScore": 3.6,
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.0"
},
{
"attackComplexity": "Low",
"attackVector": "Adjacent Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 6.5,
"baseSeverity": "Medium",
"confidentialityImpact": "None",
"exploitabilityScore": null,
"id": "CVE-2017-6865",
"impactScore": null,
"integrityImpact": "None",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2017-6865",
"trust": 1.8,
"value": "MEDIUM"
},
{
"author": "CNVD",
"id": "CNVD-2017-06152",
"trust": 0.6,
"value": "MEDIUM"
},
{
"author": "CNNVD",
"id": "CNNVD-201703-632",
"trust": 0.6,
"value": "MEDIUM"
},
{
"author": "IVD",
"id": "1b7b75ad-c1f6-4e73-be28-ff3e458e7677",
"trust": 0.2,
"value": "MEDIUM"
},
{
"author": "VULHUB",
"id": "VHN-115068",
"trust": 0.1,
"value": "MEDIUM"
}
]
}
],
"sources": [
{
"db": "IVD",
"id": "1b7b75ad-c1f6-4e73-be28-ff3e458e7677"
},
{
"db": "CNVD",
"id": "CNVD-2017-06152"
},
{
"db": "VULHUB",
"id": "VHN-115068"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-004136"
},
{
"db": "NVD",
"id": "CVE-2017-6865"
},
{
"db": "CNNVD",
"id": "CNNVD-201703-632"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "A vulnerability has been identified in Primary Setup Tool (PST) (All versions \u003c V4.2 HF1), SIMATIC Automation Tool (All versions \u003c V3.0), SIMATIC NET PC-Software (All versions \u003c V14 SP1), SIMATIC PCS 7 V8.1 (All versions), SIMATIC PCS 7 V8.2 (All versions \u003c V8.2 SP1), SIMATIC STEP 7 (TIA Portal) V13 (All versions \u003c V13 SP2), SIMATIC STEP 7 (TIA Portal) V14 (All versions \u003c V14 SP1), SIMATIC STEP 7 V5.X (All versions \u003c V5.6), SIMATIC WinAC RTX 2010 SP2 (All versions), SIMATIC WinAC RTX F 2010 SP2 (All versions), SIMATIC WinCC (TIA Portal) V13 (All versions \u003c V13 SP2), SIMATIC WinCC (TIA Portal) V14 (All versions \u003c V14 SP1), SIMATIC WinCC V7.2 and prior (All versions), SIMATIC WinCC V7.3 (All versions \u003c V7.3 Update 15), SIMATIC WinCC V7.4 (All versions \u003c V7.4 SP1 Upd1), SIMATIC WinCC flexible 2008 (All versions \u003c flexible 2008 SP5), SINAUT ST7CC (All versions installed in conjunction with SIMATIC WinCC \u003c V7.3 Update 15), SINEMA Server (All versions \u003c V14), SINUMERIK 808D Programming Tool (All versions \u003c V4.7 SP4 HF2), SMART PC Access (All versions \u003c V2.3), STEP 7 - Micro/WIN SMART (All versions \u003c V2.3), Security Configuration Tool (SCT) (All versions \u003c V5.0). Specially crafted PROFINET DCP broadcast packets sent to the affected products on a local Ethernet segment (Layer 2) could cause a Denial-of-Service condition of some services. The services require manual restart to recover. SIMATIC WinCC (TIA Portal), SIMATIC STEP 7, SMART PC Access, SIMATIC Automation Tool, etc. are all industrial automation products from Siemens AG. A number of Siemens industrial products have a denial of service vulnerability. \nAttackers can exploit this issue to crash the affected device, denying service to legitimate users. Siemens SIMATIC WinCC, etc. Siemens SIMATIC WinCC is an automated data acquisition and monitoring (SCADA) system; SIMATIC PCS 7 is a distributed process control system using WinCC",
"sources": [
{
"db": "NVD",
"id": "CVE-2017-6865"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-004136"
},
{
"db": "CNVD",
"id": "CNVD-2017-06152"
},
{
"db": "BID",
"id": "98366"
},
{
"db": "IVD",
"id": "1b7b75ad-c1f6-4e73-be28-ff3e458e7677"
},
{
"db": "VULHUB",
"id": "VHN-115068"
}
],
"trust": 2.7
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2017-6865",
"trust": 3.6
},
{
"db": "BID",
"id": "98366",
"trust": 2.0
},
{
"db": "SIEMENS",
"id": "SSA-275839",
"trust": 1.7
},
{
"db": "ICS CERT",
"id": "ICSA-17-129-01",
"trust": 1.1
},
{
"db": "CNNVD",
"id": "CNNVD-201703-632",
"trust": 0.9
},
{
"db": "CNVD",
"id": "CNVD-2017-06152",
"trust": 0.8
},
{
"db": "JVNDB",
"id": "JVNDB-2017-004136",
"trust": 0.8
},
{
"db": "IVD",
"id": "1B7B75AD-C1F6-4E73-BE28-FF3E458E7677",
"trust": 0.2
},
{
"db": "VULHUB",
"id": "VHN-115068",
"trust": 0.1
}
],
"sources": [
{
"db": "IVD",
"id": "1b7b75ad-c1f6-4e73-be28-ff3e458e7677"
},
{
"db": "CNVD",
"id": "CNVD-2017-06152"
},
{
"db": "VULHUB",
"id": "VHN-115068"
},
{
"db": "BID",
"id": "98366"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-004136"
},
{
"db": "NVD",
"id": "CVE-2017-6865"
},
{
"db": "CNNVD",
"id": "CNNVD-201703-632"
}
]
},
"id": "VAR-201705-3973",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "IVD",
"id": "1b7b75ad-c1f6-4e73-be28-ff3e458e7677"
},
{
"db": "CNVD",
"id": "CNVD-2017-06152"
},
{
"db": "VULHUB",
"id": "VHN-115068"
}
],
"trust": 1.5864798616
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"ICS"
],
"sub_category": null,
"trust": 0.8
}
],
"sources": [
{
"db": "IVD",
"id": "1b7b75ad-c1f6-4e73-be28-ff3e458e7677"
},
{
"db": "CNVD",
"id": "CNVD-2017-06152"
}
]
},
"last_update_date": "2023-12-18T12:44:33.034000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "SSA-275839",
"trust": 0.8,
"url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-275839.pdf"
},
{
"title": "There are patches for denial of service vulnerabilities in many Siemens products",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchinfo/show/93344"
},
{
"title": "Multiple Siemens Fixes for product input validation vulnerabilities",
"trust": 0.6,
"url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=90621"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2017-06152"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-004136"
},
{
"db": "CNNVD",
"id": "CNNVD-201703-632"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-20",
"trust": 1.9
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-115068"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-004136"
},
{
"db": "NVD",
"id": "CVE-2017-6865"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.7,
"url": "https://www.securityfocus.com/bid/98366"
},
{
"trust": 1.7,
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-275839.pdf"
},
{
"trust": 1.1,
"url": "https://ics-cert.us-cert.gov/advisories/icsa-17-129-01"
},
{
"trust": 0.8,
"url": "http://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2017-6865"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2017-6865"
},
{
"trust": 0.6,
"url": "http://www.siemens.com/cert/en/cert-security-advisories.htm"
},
{
"trust": 0.3,
"url": "http://www.siemens.com/"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2017-06152"
},
{
"db": "VULHUB",
"id": "VHN-115068"
},
{
"db": "BID",
"id": "98366"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-004136"
},
{
"db": "NVD",
"id": "CVE-2017-6865"
},
{
"db": "CNNVD",
"id": "CNNVD-201703-632"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "IVD",
"id": "1b7b75ad-c1f6-4e73-be28-ff3e458e7677"
},
{
"db": "CNVD",
"id": "CNVD-2017-06152"
},
{
"db": "VULHUB",
"id": "VHN-115068"
},
{
"db": "BID",
"id": "98366"
},
{
"db": "JVNDB",
"id": "JVNDB-2017-004136"
},
{
"db": "NVD",
"id": "CVE-2017-6865"
},
{
"db": "CNNVD",
"id": "CNNVD-201703-632"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2017-05-09T00:00:00",
"db": "IVD",
"id": "1b7b75ad-c1f6-4e73-be28-ff3e458e7677"
},
{
"date": "2017-05-09T00:00:00",
"db": "CNVD",
"id": "CNVD-2017-06152"
},
{
"date": "2017-05-11T00:00:00",
"db": "VULHUB",
"id": "VHN-115068"
},
{
"date": "2017-05-09T00:00:00",
"db": "BID",
"id": "98366"
},
{
"date": "2017-06-16T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2017-004136"
},
{
"date": "2017-05-11T10:29:00.227000",
"db": "NVD",
"id": "CVE-2017-6865"
},
{
"date": "2017-03-16T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201703-632"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2017-05-09T00:00:00",
"db": "CNVD",
"id": "CNVD-2017-06152"
},
{
"date": "2019-03-21T00:00:00",
"db": "VULHUB",
"id": "VHN-115068"
},
{
"date": "2017-05-23T16:23:00",
"db": "BID",
"id": "98366"
},
{
"date": "2017-09-11T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2017-004136"
},
{
"date": "2019-03-21T16:29:00.407000",
"db": "NVD",
"id": "CVE-2017-6865"
},
{
"date": "2019-04-01T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201703-632"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote or local",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201703-632"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "plural Siemens Service disruption in products (DoS) Vulnerabilities",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2017-004136"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Input validation",
"sources": [
{
"db": "IVD",
"id": "1b7b75ad-c1f6-4e73-be28-ff3e458e7677"
},
{
"db": "CNNVD",
"id": "CNNVD-201703-632"
}
],
"trust": 0.8
}
}
VAR-201808-0743
Vulnerability from variot - Updated: 2023-12-18 12:43A vulnerability has been identified in SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V10, V11, V12 (All versions), SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V13 (All versions < V13 SP2 Update 2), SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V14 (All versions < V14 SP1 Update 6), SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V15 (All versions < V15 Update 2). Improper file permissions in the default installation of TIA Portal may allow an attacker with local file system access to insert specially crafted files which may prevent TIA Portal startup (Denial-of-Service) or lead to local code execution. No special privileges are required, but the victim needs to attempt to start TIA Portal after the manipulation. SIMATIC STEP 7 and WinCC (TIA Portal ) Contains vulnerabilities related to authorization, permissions, and access control.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. Siemens SIMATIC STEP 7 (TIA Portal) is a set of programming software for SIMATIC controllers. The software provides PLC programming, design option packages and advanced drive technology. WinCC (TIA Portal) is an automated data acquisition and monitoring (SCADA) system. The system provides functions such as process monitoring and data acquisition. The Portal starts, causing a denial of service or execution of code. Siemens SIMATIC STEP 7 and SIMATIC WinCC are prone to multiple insecure file-permissions vulnerabilities. A local attacker can exploit these issues by gaining access to a world-readable file and extracting sensitive information from it. Information obtained may aid in other attacks
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-201808-0743",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "simatic wincc \\",
"scope": "eq",
"trust": 1.6,
"vendor": "siemens",
"version": "15.0"
},
{
"model": "simatic step 7 \\",
"scope": "eq",
"trust": 1.6,
"vendor": "siemens",
"version": "13.0"
},
{
"model": "simatic step 7 \\",
"scope": "eq",
"trust": 1.6,
"vendor": "siemens",
"version": "15.0"
},
{
"model": "simatic wincc \\",
"scope": "eq",
"trust": 1.6,
"vendor": "siemens",
"version": "13.0"
},
{
"model": "simatic step 7 \\",
"scope": "eq",
"trust": 1.6,
"vendor": "siemens",
"version": "11.0"
},
{
"model": "simatic wincc \\",
"scope": "eq",
"trust": 1.6,
"vendor": "siemens",
"version": "14.0"
},
{
"model": "simatic step 7 \\",
"scope": "eq",
"trust": 1.6,
"vendor": "siemens",
"version": "10.0"
},
{
"model": "simatic step 7 \\",
"scope": "eq",
"trust": 1.6,
"vendor": "siemens",
"version": "14.0"
},
{
"model": "simatic step 7 \\",
"scope": "eq",
"trust": 1.6,
"vendor": "siemens",
"version": "12.0"
},
{
"model": "simatic wincc \\",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "10.0"
},
{
"model": "simatic wincc \\",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "11.0"
},
{
"model": "simatic wincc \\",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "12.0"
},
{
"model": "simatic step 7",
"scope": null,
"trust": 0.8,
"vendor": "siemens",
"version": null
},
{
"model": "simatic wincc",
"scope": null,
"trust": 0.8,
"vendor": "siemens",
"version": null
},
{
"model": "simatic step",
"scope": "eq",
"trust": 0.6,
"vendor": "siemens",
"version": "710"
},
{
"model": "simatic step",
"scope": "eq",
"trust": 0.6,
"vendor": "siemens",
"version": "711"
},
{
"model": "simatic step",
"scope": "eq",
"trust": 0.6,
"vendor": "siemens",
"version": "712"
},
{
"model": "simatic step",
"scope": "eq",
"trust": 0.6,
"vendor": "siemens",
"version": "713"
},
{
"model": "simatic step sp1 update",
"scope": "eq",
"trust": 0.6,
"vendor": "siemens",
"version": "714.*\u003c146"
},
{
"model": "simatic step update",
"scope": "eq",
"trust": 0.6,
"vendor": "siemens",
"version": "715.*\u003c152"
},
{
"model": "wincc",
"scope": "eq",
"trust": 0.6,
"vendor": "siemens",
"version": "10"
},
{
"model": "wincc",
"scope": "eq",
"trust": 0.6,
"vendor": "siemens",
"version": "11"
},
{
"model": "wincc",
"scope": "eq",
"trust": 0.6,
"vendor": "siemens",
"version": "12"
},
{
"model": "wincc",
"scope": "eq",
"trust": 0.6,
"vendor": "siemens",
"version": "13"
},
{
"model": "wincc sp1 update",
"scope": "eq",
"trust": 0.6,
"vendor": "siemens",
"version": "14.*\u003c146"
},
{
"model": "wincc update",
"scope": "eq",
"trust": 0.6,
"vendor": "siemens",
"version": "15.*\u003c152"
},
{
"model": null,
"scope": "eq",
"trust": 0.4,
"vendor": "simatic step 7 tia portal",
"version": "13.0"
},
{
"model": "simatic wincc",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "v120"
},
{
"model": "simatic wincc",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "v110"
},
{
"model": "simatic wincc",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "v15"
},
{
"model": "simatic wincc",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "v13"
},
{
"model": "simatic wincc",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "v11"
},
{
"model": "simatic wincc",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "v10"
},
{
"model": "simatic step tia portal",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "7v14"
},
{
"model": "simatic step tia portal",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "7v13"
},
{
"model": "simatic step tia portal",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "7v12"
},
{
"model": "simatic step",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "7v15"
},
{
"model": "simatic step",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "7v11"
},
{
"model": "simatic step",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "7v10"
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "simatic step 7 tia portal",
"version": "10.0"
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "simatic step 7 tia portal",
"version": "11.0"
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "simatic step 7 tia portal",
"version": "12.0"
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "simatic step 7 tia portal",
"version": "14.0"
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "simatic step 7 tia portal",
"version": "15.0"
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "simatic wincc tia portal",
"version": "10.0"
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "simatic wincc tia portal",
"version": "11.0"
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "simatic wincc tia portal",
"version": "12.0"
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "simatic wincc tia portal",
"version": "13.0"
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "simatic wincc tia portal",
"version": "14.0"
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "simatic wincc tia portal",
"version": "15.0"
}
],
"sources": [
{
"db": "IVD",
"id": "e2fc57cf-39ab-11e9-b215-000c29342cb1"
},
{
"db": "CNVD",
"id": "CNVD-2018-19601"
},
{
"db": "BID",
"id": "105115"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-009209"
},
{
"db": "NVD",
"id": "CVE-2018-11453"
},
{
"db": "CNNVD",
"id": "CNNVD-201808-241"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:a:siemens:simatic_step_7_\\(tia_portal\\):13.0:sp1:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:simatic_wincc_\\(tia_portal\\):10.0:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:simatic_wincc_\\(tia_portal\\):11.0:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:simatic_wincc_\\(tia_portal\\):12.0:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:simatic_wincc_\\(tia_portal\\):13.0:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:simatic_wincc_\\(tia_portal\\):15.0:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:simatic_step_7_\\(tia_portal\\):11.0:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:simatic_step_7_\\(tia_portal\\):12.0:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:simatic_step_7_\\(tia_portal\\):13.0:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:simatic_step_7_\\(tia_portal\\):14.0:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:simatic_wincc_\\(tia_portal\\):14.0:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:simatic_step_7_\\(tia_portal\\):10.0:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:simatic_step_7_\\(tia_portal\\):15.0:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2018-11453"
}
]
},
"credits": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/credits#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Younes Dragoni from Nozomi Networks.",
"sources": [
{
"db": "BID",
"id": "105115"
}
],
"trust": 0.3
},
"cve": "CVE-2018-11453",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"acInsufInfo": false,
"accessComplexity": "LOW",
"accessVector": "LOCAL",
"authentication": "NONE",
"author": "NVD",
"availabilityImpact": "PARTIAL",
"baseScore": 4.6,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 3.9,
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "MEDIUM",
"trust": 1.0,
"userInteractionRequired": false,
"vectorString": "AV:L/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
{
"acInsufInfo": null,
"accessComplexity": "Low",
"accessVector": "Local",
"authentication": "None",
"author": "NVD",
"availabilityImpact": "Partial",
"baseScore": 4.6,
"confidentialityImpact": "Partial",
"exploitabilityScore": null,
"id": "CVE-2018-11453",
"impactScore": null,
"integrityImpact": "Partial",
"obtainAllPrivilege": null,
"obtainOtherPrivilege": null,
"obtainUserPrivilege": null,
"severity": "Medium",
"trust": 0.8,
"userInteractionRequired": null,
"vectorString": "AV:L/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "LOCAL",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 7.2,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 3.9,
"id": "CNVD-2018-19601",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:L/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "LOCAL",
"authentication": "NONE",
"author": "IVD",
"availabilityImpact": "COMPLETE",
"baseScore": 7.2,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 3.9,
"id": "e2fc57cf-39ab-11e9-b215-000c29342cb1",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.2,
"vectorString": "AV:L/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.9 [IVD]"
},
{
"accessComplexity": "LOW",
"accessVector": "LOCAL",
"authentication": "NONE",
"author": "VULHUB",
"availabilityImpact": "PARTIAL",
"baseScore": 4.6,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 3.9,
"id": "VHN-121314",
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"severity": "MEDIUM",
"trust": 0.1,
"vectorString": "AV:L/AC:L/AU:N/C:P/I:P/A:P",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"author": "NVD",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 1.8,
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
},
{
"attackComplexity": "Low",
"attackVector": "Local",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 7.8,
"baseSeverity": "High",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "CVE-2018-11453",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "Low",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2018-11453",
"trust": 1.8,
"value": "HIGH"
},
{
"author": "CNVD",
"id": "CNVD-2018-19601",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "CNNVD",
"id": "CNNVD-201808-241",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "IVD",
"id": "e2fc57cf-39ab-11e9-b215-000c29342cb1",
"trust": 0.2,
"value": "HIGH"
},
{
"author": "VULHUB",
"id": "VHN-121314",
"trust": 0.1,
"value": "MEDIUM"
}
]
}
],
"sources": [
{
"db": "IVD",
"id": "e2fc57cf-39ab-11e9-b215-000c29342cb1"
},
{
"db": "CNVD",
"id": "CNVD-2018-19601"
},
{
"db": "VULHUB",
"id": "VHN-121314"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-009209"
},
{
"db": "NVD",
"id": "CVE-2018-11453"
},
{
"db": "CNNVD",
"id": "CNNVD-201808-241"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "A vulnerability has been identified in SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V10, V11, V12 (All versions), SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V13 (All versions \u003c V13 SP2 Update 2), SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V14 (All versions \u003c V14 SP1 Update 6), SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V15 (All versions \u003c V15 Update 2). Improper file permissions in the default installation of TIA Portal may allow an attacker with local file system access to insert specially crafted files which may prevent TIA Portal startup (Denial-of-Service) or lead to local code execution. No special privileges are required, but the victim needs to attempt to start TIA Portal after the manipulation. SIMATIC STEP 7 and WinCC (TIA Portal ) Contains vulnerabilities related to authorization, permissions, and access control.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. Siemens SIMATIC STEP 7 (TIA Portal) is a set of programming software for SIMATIC controllers. The software provides PLC programming, design option packages and advanced drive technology. WinCC (TIA Portal) is an automated data acquisition and monitoring (SCADA) system. The system provides functions such as process monitoring and data acquisition. The Portal starts, causing a denial of service or execution of code. Siemens SIMATIC STEP 7 and SIMATIC WinCC are prone to multiple insecure file-permissions vulnerabilities. \nA local attacker can exploit these issues by gaining access to a world-readable file and extracting sensitive information from it. Information obtained may aid in other attacks",
"sources": [
{
"db": "NVD",
"id": "CVE-2018-11453"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-009209"
},
{
"db": "CNVD",
"id": "CNVD-2018-19601"
},
{
"db": "BID",
"id": "105115"
},
{
"db": "IVD",
"id": "e2fc57cf-39ab-11e9-b215-000c29342cb1"
},
{
"db": "VULHUB",
"id": "VHN-121314"
}
],
"trust": 2.7
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2018-11453",
"trust": 3.6
},
{
"db": "SIEMENS",
"id": "SSA-979106",
"trust": 2.3
},
{
"db": "BID",
"id": "105115",
"trust": 2.0
},
{
"db": "ICS CERT",
"id": "ICSA-18-226-01",
"trust": 1.1
},
{
"db": "CNNVD",
"id": "CNNVD-201808-241",
"trust": 0.9
},
{
"db": "CNVD",
"id": "CNVD-2018-19601",
"trust": 0.8
},
{
"db": "JVNDB",
"id": "JVNDB-2018-009209",
"trust": 0.8
},
{
"db": "IVD",
"id": "E2FC57CF-39AB-11E9-B215-000C29342CB1",
"trust": 0.2
},
{
"db": "VULHUB",
"id": "VHN-121314",
"trust": 0.1
}
],
"sources": [
{
"db": "IVD",
"id": "e2fc57cf-39ab-11e9-b215-000c29342cb1"
},
{
"db": "CNVD",
"id": "CNVD-2018-19601"
},
{
"db": "VULHUB",
"id": "VHN-121314"
},
{
"db": "BID",
"id": "105115"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-009209"
},
{
"db": "NVD",
"id": "CVE-2018-11453"
},
{
"db": "CNNVD",
"id": "CNNVD-201808-241"
}
]
},
"id": "VAR-201808-0743",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "IVD",
"id": "e2fc57cf-39ab-11e9-b215-000c29342cb1"
},
{
"db": "CNVD",
"id": "CNVD-2018-19601"
},
{
"db": "VULHUB",
"id": "VHN-121314"
}
],
"trust": 1.6596514042857142
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"ICS"
],
"sub_category": null,
"trust": 0.8
}
],
"sources": [
{
"db": "IVD",
"id": "e2fc57cf-39ab-11e9-b215-000c29342cb1"
},
{
"db": "CNVD",
"id": "CNVD-2018-19601"
}
]
},
"last_update_date": "2023-12-18T12:43:53.749000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "SSA-979106",
"trust": 0.8,
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-979106.pdf"
},
{
"title": "Patch for Siemens SIMATIC STEP 7 and WinCC Denial of Service Vulnerabilities",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchinfo/show/140877"
},
{
"title": "Siemens SIMATIC STEP 7 and WinCC Security vulnerabilities",
"trust": 0.6,
"url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=83960"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2018-19601"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-009209"
},
{
"db": "CNNVD",
"id": "CNNVD-201808-241"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-732",
"trust": 1.1
},
{
"problemtype": "CWE-264",
"trust": 0.9
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-121314"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-009209"
},
{
"db": "NVD",
"id": "CVE-2018-11453"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.3,
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-979106.pdf"
},
{
"trust": 1.7,
"url": "http://www.securityfocus.com/bid/105115"
},
{
"trust": 1.1,
"url": "https://ics-cert.us-cert.gov/advisories/icsa-18-226-01"
},
{
"trust": 0.8,
"url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2018-11453"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2018-11453"
},
{
"trust": 0.3,
"url": "http://www.siemens.com/"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2018-19601"
},
{
"db": "VULHUB",
"id": "VHN-121314"
},
{
"db": "BID",
"id": "105115"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-009209"
},
{
"db": "NVD",
"id": "CVE-2018-11453"
},
{
"db": "CNNVD",
"id": "CNNVD-201808-241"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "IVD",
"id": "e2fc57cf-39ab-11e9-b215-000c29342cb1"
},
{
"db": "CNVD",
"id": "CNVD-2018-19601"
},
{
"db": "VULHUB",
"id": "VHN-121314"
},
{
"db": "BID",
"id": "105115"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-009209"
},
{
"db": "NVD",
"id": "CVE-2018-11453"
},
{
"db": "CNNVD",
"id": "CNNVD-201808-241"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2018-09-21T00:00:00",
"db": "IVD",
"id": "e2fc57cf-39ab-11e9-b215-000c29342cb1"
},
{
"date": "2018-09-21T00:00:00",
"db": "CNVD",
"id": "CNVD-2018-19601"
},
{
"date": "2018-08-07T00:00:00",
"db": "VULHUB",
"id": "VHN-121314"
},
{
"date": "2018-08-14T00:00:00",
"db": "BID",
"id": "105115"
},
{
"date": "2018-11-12T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2018-009209"
},
{
"date": "2018-08-07T15:29:00.247000",
"db": "NVD",
"id": "CVE-2018-11453"
},
{
"date": "2018-08-08T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201808-241"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2018-09-21T00:00:00",
"db": "CNVD",
"id": "CNVD-2018-19601"
},
{
"date": "2019-10-09T00:00:00",
"db": "VULHUB",
"id": "VHN-121314"
},
{
"date": "2018-08-14T00:00:00",
"db": "BID",
"id": "105115"
},
{
"date": "2019-01-08T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2018-009209"
},
{
"date": "2019-10-09T23:33:32.137000",
"db": "NVD",
"id": "CVE-2018-11453"
},
{
"date": "2019-10-17T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201808-241"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "local",
"sources": [
{
"db": "BID",
"id": "105115"
},
{
"db": "CNNVD",
"id": "CNNVD-201808-241"
}
],
"trust": 0.9
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "SIMATIC STEP 7 and WinCC Vulnerabilities related to authorization, permissions, and access control",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2018-009209"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "permissions and access control issues",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201808-241"
}
],
"trust": 0.6
}
}
VAR-201808-0744
Vulnerability from variot - Updated: 2023-12-18 12:43A vulnerability has been identified in SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V10, V11, V12 (All versions), SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V13 (All versions < V13 SP2 Update 2), SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V14 (All versions < V14 SP1 Update 6), SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V15 (All versions < V15 Update 2). Improper file permissions in the default installation of TIA Portal may allow an attacker with local file system access to manipulate resources which may be transferred to devices and executed there by a different user. No special privileges are required, but the victim needs to transfer the manipulated files to a device. Execution is caused on the target device rather than on the PG device. SIMATIC STEP 7 and WinCC (TIA Portal ) Contains vulnerabilities related to authorization, permissions, and access control.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. Siemens SIMATIC STEP 7 (TIA Portal) is a set of programming software for SIMATIC controllers. The software provides PLC programming, design option packages and advanced drive technology. WinCC (TIA Portal) is an automated data acquisition and monitoring (SCADA) system. The system provides functions such as process monitoring and data acquisition. And resources that are executed by the user. Siemens SIMATIC STEP 7 and SIMATIC WinCC are prone to multiple insecure file-permissions vulnerabilities. A local attacker can exploit these issues by gaining access to a world-readable file and extracting sensitive information from it. Information obtained may aid in other attacks
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-201808-0744",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "simatic wincc \\",
"scope": "eq",
"trust": 1.6,
"vendor": "siemens",
"version": "15.0"
},
{
"model": "simatic step 7 \\",
"scope": "eq",
"trust": 1.6,
"vendor": "siemens",
"version": "13.0"
},
{
"model": "simatic step 7 \\",
"scope": "eq",
"trust": 1.6,
"vendor": "siemens",
"version": "15.0"
},
{
"model": "simatic wincc \\",
"scope": "eq",
"trust": 1.6,
"vendor": "siemens",
"version": "13.0"
},
{
"model": "simatic wincc \\",
"scope": "eq",
"trust": 1.6,
"vendor": "siemens",
"version": "10.0"
},
{
"model": "simatic wincc \\",
"scope": "eq",
"trust": 1.6,
"vendor": "siemens",
"version": "11.0"
},
{
"model": "simatic wincc \\",
"scope": "eq",
"trust": 1.6,
"vendor": "siemens",
"version": "14.0"
},
{
"model": "simatic wincc \\",
"scope": "eq",
"trust": 1.6,
"vendor": "siemens",
"version": "12.0"
},
{
"model": "simatic step 7 \\",
"scope": "eq",
"trust": 1.6,
"vendor": "siemens",
"version": "14.0"
},
{
"model": "simatic step 7 \\",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "11.0"
},
{
"model": "simatic step 7 \\",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "10.0"
},
{
"model": "simatic step 7 \\",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "12.0"
},
{
"model": "simatic step 7",
"scope": null,
"trust": 0.8,
"vendor": "siemens",
"version": null
},
{
"model": "simatic wincc",
"scope": null,
"trust": 0.8,
"vendor": "siemens",
"version": null
},
{
"model": "simatic step",
"scope": "eq",
"trust": 0.6,
"vendor": "siemens",
"version": "710"
},
{
"model": "simatic step",
"scope": "eq",
"trust": 0.6,
"vendor": "siemens",
"version": "711"
},
{
"model": "simatic step",
"scope": "eq",
"trust": 0.6,
"vendor": "siemens",
"version": "712"
},
{
"model": "simatic step",
"scope": "eq",
"trust": 0.6,
"vendor": "siemens",
"version": "713"
},
{
"model": "simatic step sp1 update",
"scope": "eq",
"trust": 0.6,
"vendor": "siemens",
"version": "714.*\u003c146"
},
{
"model": "simatic step update",
"scope": "eq",
"trust": 0.6,
"vendor": "siemens",
"version": "715.*\u003c152"
},
{
"model": "wincc",
"scope": "eq",
"trust": 0.6,
"vendor": "siemens",
"version": "10"
},
{
"model": "wincc",
"scope": "eq",
"trust": 0.6,
"vendor": "siemens",
"version": "11"
},
{
"model": "wincc",
"scope": "eq",
"trust": 0.6,
"vendor": "siemens",
"version": "12"
},
{
"model": "wincc",
"scope": "eq",
"trust": 0.6,
"vendor": "siemens",
"version": "13"
},
{
"model": "wincc sp1 update",
"scope": "eq",
"trust": 0.6,
"vendor": "siemens",
"version": "14.*\u003c146"
},
{
"model": "wincc update",
"scope": "eq",
"trust": 0.6,
"vendor": "siemens",
"version": "15.*\u003c152"
},
{
"model": null,
"scope": "eq",
"trust": 0.4,
"vendor": "simatic step 7 tia portal",
"version": "13.0"
},
{
"model": "simatic wincc",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "v120"
},
{
"model": "simatic wincc",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "v110"
},
{
"model": "simatic wincc",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "v15"
},
{
"model": "simatic wincc",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "v13"
},
{
"model": "simatic wincc",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "v11"
},
{
"model": "simatic wincc",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "v10"
},
{
"model": "simatic step tia portal",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "7v14"
},
{
"model": "simatic step tia portal",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "7v13"
},
{
"model": "simatic step tia portal",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "7v12"
},
{
"model": "simatic step",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "7v15"
},
{
"model": "simatic step",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "7v11"
},
{
"model": "simatic step",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "7v10"
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "simatic step 7 tia portal",
"version": "10.0"
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "simatic step 7 tia portal",
"version": "11.0"
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "simatic step 7 tia portal",
"version": "12.0"
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "simatic step 7 tia portal",
"version": "14.0"
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "simatic step 7 tia portal",
"version": "15.0"
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "simatic wincc tia portal",
"version": "10.0"
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "simatic wincc tia portal",
"version": "11.0"
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "simatic wincc tia portal",
"version": "12.0"
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "simatic wincc tia portal",
"version": "13.0"
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "simatic wincc tia portal",
"version": "14.0"
},
{
"model": null,
"scope": "eq",
"trust": 0.2,
"vendor": "simatic wincc tia portal",
"version": "15.0"
}
],
"sources": [
{
"db": "IVD",
"id": "e2fc30c0-39ab-11e9-8ae0-000c29342cb1"
},
{
"db": "CNVD",
"id": "CNVD-2018-19602"
},
{
"db": "BID",
"id": "105115"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-009208"
},
{
"db": "NVD",
"id": "CVE-2018-11454"
},
{
"db": "CNNVD",
"id": "CNNVD-201808-240"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:a:siemens:simatic_wincc_\\(tia_portal\\):11.0:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:simatic_wincc_\\(tia_portal\\):12.0:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:simatic_wincc_\\(tia_portal\\):13.0:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:simatic_wincc_\\(tia_portal\\):10.0:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:simatic_step_7_\\(tia_portal\\):11.0:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:simatic_step_7_\\(tia_portal\\):13.0:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:simatic_step_7_\\(tia_portal\\):14.0:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:simatic_step_7_\\(tia_portal\\):15.0:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:simatic_wincc_\\(tia_portal\\):14.0:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:simatic_wincc_\\(tia_portal\\):15.0:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:simatic_step_7_\\(tia_portal\\):13.0:sp1:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:simatic_step_7_\\(tia_portal\\):10.0:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:simatic_step_7_\\(tia_portal\\):12.0:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2018-11454"
}
]
},
"credits": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/credits#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Younes Dragoni from Nozomi Networks.",
"sources": [
{
"db": "BID",
"id": "105115"
}
],
"trust": 0.3
},
"cve": "CVE-2018-11454",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"acInsufInfo": false,
"accessComplexity": "MEDIUM",
"accessVector": "LOCAL",
"authentication": "NONE",
"author": "NVD",
"availabilityImpact": "PARTIAL",
"baseScore": 4.4,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 3.4,
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "MEDIUM",
"trust": 1.0,
"userInteractionRequired": true,
"vectorString": "AV:L/AC:M/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
{
"acInsufInfo": null,
"accessComplexity": "Medium",
"accessVector": "Local",
"authentication": "None",
"author": "NVD",
"availabilityImpact": "Partial",
"baseScore": 4.4,
"confidentialityImpact": "Partial",
"exploitabilityScore": null,
"id": "CVE-2018-11454",
"impactScore": null,
"integrityImpact": "Partial",
"obtainAllPrivilege": null,
"obtainOtherPrivilege": null,
"obtainUserPrivilege": null,
"severity": "Medium",
"trust": 0.8,
"userInteractionRequired": null,
"vectorString": "AV:L/AC:M/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "LOCAL",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 7.2,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 3.9,
"id": "CNVD-2018-19602",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:L/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "LOCAL",
"authentication": "NONE",
"author": "IVD",
"availabilityImpact": "COMPLETE",
"baseScore": 7.2,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 3.9,
"id": "e2fc30c0-39ab-11e9-8ae0-000c29342cb1",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.2,
"vectorString": "AV:L/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.9 [IVD]"
},
{
"accessComplexity": "MEDIUM",
"accessVector": "LOCAL",
"authentication": "NONE",
"author": "VULHUB",
"availabilityImpact": "PARTIAL",
"baseScore": 4.4,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 3.4,
"id": "VHN-121315",
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"severity": "MEDIUM",
"trust": 0.1,
"vectorString": "AV:L/AC:M/AU:N/C:P/I:P/A:P",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"author": "NVD",
"availabilityImpact": "HIGH",
"baseScore": 8.6,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 1.8,
"impactScore": 6.0,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"trust": 1.0,
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:C/C:H/I:H/A:H",
"version": "3.0"
},
{
"attackComplexity": "Low",
"attackVector": "Local",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 8.6,
"baseSeverity": "High",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "CVE-2018-11454",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "None",
"scope": "Changed",
"trust": 0.8,
"userInteraction": "Required",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:C/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2018-11454",
"trust": 1.8,
"value": "HIGH"
},
{
"author": "CNVD",
"id": "CNVD-2018-19602",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "CNNVD",
"id": "CNNVD-201808-240",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "IVD",
"id": "e2fc30c0-39ab-11e9-8ae0-000c29342cb1",
"trust": 0.2,
"value": "HIGH"
},
{
"author": "VULHUB",
"id": "VHN-121315",
"trust": 0.1,
"value": "MEDIUM"
}
]
}
],
"sources": [
{
"db": "IVD",
"id": "e2fc30c0-39ab-11e9-8ae0-000c29342cb1"
},
{
"db": "CNVD",
"id": "CNVD-2018-19602"
},
{
"db": "VULHUB",
"id": "VHN-121315"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-009208"
},
{
"db": "NVD",
"id": "CVE-2018-11454"
},
{
"db": "CNNVD",
"id": "CNNVD-201808-240"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "A vulnerability has been identified in SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V10, V11, V12 (All versions), SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V13 (All versions \u003c V13 SP2 Update 2), SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V14 (All versions \u003c V14 SP1 Update 6), SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V15 (All versions \u003c V15 Update 2). Improper file permissions in the default installation of TIA Portal may allow an attacker with local file system access to manipulate resources which may be transferred to devices and executed there by a different user. No special privileges are required, but the victim needs to transfer the manipulated files to a device. Execution is caused on the target device rather than on the PG device. SIMATIC STEP 7 and WinCC (TIA Portal ) Contains vulnerabilities related to authorization, permissions, and access control.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. Siemens SIMATIC STEP 7 (TIA Portal) is a set of programming software for SIMATIC controllers. The software provides PLC programming, design option packages and advanced drive technology. WinCC (TIA Portal) is an automated data acquisition and monitoring (SCADA) system. The system provides functions such as process monitoring and data acquisition. And resources that are executed by the user. Siemens SIMATIC STEP 7 and SIMATIC WinCC are prone to multiple insecure file-permissions vulnerabilities. \nA local attacker can exploit these issues by gaining access to a world-readable file and extracting sensitive information from it. Information obtained may aid in other attacks",
"sources": [
{
"db": "NVD",
"id": "CVE-2018-11454"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-009208"
},
{
"db": "CNVD",
"id": "CNVD-2018-19602"
},
{
"db": "BID",
"id": "105115"
},
{
"db": "IVD",
"id": "e2fc30c0-39ab-11e9-8ae0-000c29342cb1"
},
{
"db": "VULHUB",
"id": "VHN-121315"
}
],
"trust": 2.7
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2018-11454",
"trust": 3.6
},
{
"db": "SIEMENS",
"id": "SSA-979106",
"trust": 2.3
},
{
"db": "BID",
"id": "105115",
"trust": 2.0
},
{
"db": "ICS CERT",
"id": "ICSA-18-226-01",
"trust": 1.1
},
{
"db": "CNNVD",
"id": "CNNVD-201808-240",
"trust": 0.9
},
{
"db": "CNVD",
"id": "CNVD-2018-19602",
"trust": 0.8
},
{
"db": "JVNDB",
"id": "JVNDB-2018-009208",
"trust": 0.8
},
{
"db": "IVD",
"id": "E2FC30C0-39AB-11E9-8AE0-000C29342CB1",
"trust": 0.2
},
{
"db": "VULHUB",
"id": "VHN-121315",
"trust": 0.1
}
],
"sources": [
{
"db": "IVD",
"id": "e2fc30c0-39ab-11e9-8ae0-000c29342cb1"
},
{
"db": "CNVD",
"id": "CNVD-2018-19602"
},
{
"db": "VULHUB",
"id": "VHN-121315"
},
{
"db": "BID",
"id": "105115"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-009208"
},
{
"db": "NVD",
"id": "CVE-2018-11454"
},
{
"db": "CNNVD",
"id": "CNNVD-201808-240"
}
]
},
"id": "VAR-201808-0744",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "IVD",
"id": "e2fc30c0-39ab-11e9-8ae0-000c29342cb1"
},
{
"db": "CNVD",
"id": "CNVD-2018-19602"
},
{
"db": "VULHUB",
"id": "VHN-121315"
}
],
"trust": 1.6596514042857142
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"ICS"
],
"sub_category": null,
"trust": 0.8
}
],
"sources": [
{
"db": "IVD",
"id": "e2fc30c0-39ab-11e9-8ae0-000c29342cb1"
},
{
"db": "CNVD",
"id": "CNVD-2018-19602"
}
]
},
"last_update_date": "2023-12-18T12:43:53.710000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "SSA-979106",
"trust": 0.8,
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-979106.pdf"
},
{
"title": "Patch for Siemens SIMATIC STEP 7 and WinCC Rights Management Vulnerabilities",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchinfo/show/140875"
},
{
"title": "Siemens SIMATIC STEP 7 and WinCC Security vulnerabilities",
"trust": 0.6,
"url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=83959"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2018-19602"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-009208"
},
{
"db": "CNNVD",
"id": "CNNVD-201808-240"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-732",
"trust": 1.1
},
{
"problemtype": "CWE-264",
"trust": 0.9
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-121315"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-009208"
},
{
"db": "NVD",
"id": "CVE-2018-11454"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.3,
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-979106.pdf"
},
{
"trust": 1.7,
"url": "http://www.securityfocus.com/bid/105115"
},
{
"trust": 1.1,
"url": "https://ics-cert.us-cert.gov/advisories/icsa-18-226-01"
},
{
"trust": 0.8,
"url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2018-11454"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2018-11454"
},
{
"trust": 0.3,
"url": "http://www.siemens.com/"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2018-19602"
},
{
"db": "VULHUB",
"id": "VHN-121315"
},
{
"db": "BID",
"id": "105115"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-009208"
},
{
"db": "NVD",
"id": "CVE-2018-11454"
},
{
"db": "CNNVD",
"id": "CNNVD-201808-240"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "IVD",
"id": "e2fc30c0-39ab-11e9-8ae0-000c29342cb1"
},
{
"db": "CNVD",
"id": "CNVD-2018-19602"
},
{
"db": "VULHUB",
"id": "VHN-121315"
},
{
"db": "BID",
"id": "105115"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-009208"
},
{
"db": "NVD",
"id": "CVE-2018-11454"
},
{
"db": "CNNVD",
"id": "CNNVD-201808-240"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2018-09-21T00:00:00",
"db": "IVD",
"id": "e2fc30c0-39ab-11e9-8ae0-000c29342cb1"
},
{
"date": "2018-09-21T00:00:00",
"db": "CNVD",
"id": "CNVD-2018-19602"
},
{
"date": "2018-08-07T00:00:00",
"db": "VULHUB",
"id": "VHN-121315"
},
{
"date": "2018-08-14T00:00:00",
"db": "BID",
"id": "105115"
},
{
"date": "2018-11-12T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2018-009208"
},
{
"date": "2018-08-07T15:29:00.373000",
"db": "NVD",
"id": "CVE-2018-11454"
},
{
"date": "2018-08-08T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201808-240"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2018-09-21T00:00:00",
"db": "CNVD",
"id": "CNVD-2018-19602"
},
{
"date": "2019-10-09T00:00:00",
"db": "VULHUB",
"id": "VHN-121315"
},
{
"date": "2018-08-14T00:00:00",
"db": "BID",
"id": "105115"
},
{
"date": "2019-01-08T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2018-009208"
},
{
"date": "2019-10-09T23:33:32.290000",
"db": "NVD",
"id": "CVE-2018-11454"
},
{
"date": "2019-10-17T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201808-240"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "local",
"sources": [
{
"db": "BID",
"id": "105115"
},
{
"db": "CNNVD",
"id": "CNNVD-201808-240"
}
],
"trust": 0.9
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "SIMATIC STEP 7 and WinCC Vulnerabilities related to authorization, permissions, and access control",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2018-009208"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "permissions and access control issues",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201808-240"
}
],
"trust": 0.6
}
}