35 vulnerabilities by br-automation
CVE-2024-5624 (GCVE-0-2024-5624)
Vulnerability from cvelistv5 – Published: 2024-08-29 08:53 – Updated: 2024-08-29 13:40
VLAI?
Summary
Reflected Cross-Site Scripting (XSS) in Shift Logbook application of B&R APROL <= R 4.4-00P3 may allow a network-based attacker to execute arbitrary JavaScript code in the context of the user's browser session
Severity ?
CWE
- CWE-79 - Improper Neutralization of Input During Web Page Generation (XSS or 'Cross-site Scripting')
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| B&R Industrial Automation | B&R APROL |
Affected:
0 , ≤ <= R 4.4-00P3
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-5624",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-08-29T13:40:19.780879Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-08-29T13:40:31.563Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"modules": [
"Shift Logbook"
],
"product": "B\u0026R APROL",
"vendor": "B\u0026R Industrial Automation",
"versions": [
{
"lessThanOrEqual": "\u003c= R 4.4-00P3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"datePublic": "2024-08-29T08:51:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Reflected Cross-Site Scripting (XSS) in Shift Logbook application of B\u0026amp;R APROL \u0026lt;= R 4.4-00P3 may allow a network-based attacker to execute arbitrary JavaScript code in the context of the user\u0027s browser session"
}
],
"value": "Reflected Cross-Site Scripting (XSS) in Shift Logbook application of B\u0026R APROL \u003c= R 4.4-00P3 may allow a network-based attacker to execute arbitrary JavaScript code in the context of the user\u0027s browser session"
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 5.1,
"baseSeverity": "MEDIUM",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "LOW",
"subConfidentialityImpact": "LOW",
"subIntegrityImpact": "LOW",
"userInteraction": "ACTIVE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:A/VC:N/VI:N/VA:N/SC:L/SI:L/SA:L",
"version": "4.0",
"vulnAvailabilityImpact": "NONE",
"vulnConfidentialityImpact": "NONE",
"vulnIntegrityImpact": "NONE",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-79",
"description": "CWE-79 Improper Neutralization of Input During Web Page Generation (XSS or \u0027Cross-site Scripting\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-08-29T08:53:06.058Z",
"orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
"shortName": "ABB"
},
"references": [
{
"url": "https://www.br-automation.com/fileadmin/SA24P2014_Multiple_vulnerabilities_in_BR_APROL.pdf-367290ae.pdf"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Reflected Cross-Site Scripting (XSS) in Shift Logbook application of B\u0026R APROL",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
"assignerShortName": "ABB",
"cveId": "CVE-2024-5624",
"datePublished": "2024-08-29T08:53:06.058Z",
"dateReserved": "2024-06-04T08:28:17.633Z",
"dateUpdated": "2024-08-29T13:40:31.563Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-5623 (GCVE-0-2024-5623)
Vulnerability from cvelistv5 – Published: 2024-08-29 08:51 – Updated: 2024-08-29 13:46
VLAI?
Summary
An untrusted search path vulnerability in B&R APROL <= R 4.4-00P3 may be used by an authenticated local attacker to get other users to execute arbitrary code under their privileges.
Severity ?
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| B&R Industrial Automation | B&R APROL |
Affected:
0 , ≤ <= R 4.4-00P3
(custom)
|
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:br-automation:industrial_automation_aprol:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "industrial_automation_aprol",
"vendor": "br-automation",
"versions": [
{
"lessThanOrEqual": "r4.4-00p3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-5623",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-08-29T13:41:36.809403Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-08-29T13:46:16.304Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "B\u0026R APROL",
"vendor": "B\u0026R Industrial Automation",
"versions": [
{
"lessThanOrEqual": "\u003c= R 4.4-00P3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"datePublic": "2024-08-29T08:50:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "An untrusted search path vulnerability in B\u0026amp;R APROL \u0026lt;= R 4.4-00P3 may be used by an authenticated local attacker to get other users to execute arbitrary code under their privileges."
}
],
"value": "An untrusted search path vulnerability in B\u0026R APROL \u003c= R 4.4-00P3 may be used by an authenticated local attacker to get other users to execute arbitrary code under their privileges."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "PRESENT",
"attackVector": "LOCAL",
"baseScore": 5.4,
"baseSeverity": "MEDIUM",
"privilegesRequired": "LOW",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "PASSIVE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:P/PR:L/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-250",
"description": "CWE-250 Execution with Unnecessary Privileges",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-267",
"description": "CWE-267 Privilege Defined With Unsafe Actions",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-08-29T08:51:26.052Z",
"orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
"shortName": "ABB"
},
"references": [
{
"url": "https://www.br-automation.com/fileadmin/SA24P2014_Multiple_vulnerabilities_in_BR_APROL.pdf-367290ae.pdf"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Untrusted search path vulnerability in B\u0026R APROL",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
"assignerShortName": "ABB",
"cveId": "CVE-2024-5623",
"datePublished": "2024-08-29T08:51:26.052Z",
"dateReserved": "2024-06-04T08:28:15.984Z",
"dateUpdated": "2024-08-29T13:46:16.304Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-5622 (GCVE-0-2024-5622)
Vulnerability from cvelistv5 – Published: 2024-08-29 08:49 – Updated: 2024-08-29 13:29
VLAI?
Summary
An untrusted search path vulnerability in the AprolConfigureCCServices of B&R APROL <= R 4.2.-07P3 and <= R 4.4-00P3 may allow an authenticated local attacker to execute arbitrary code with elevated privileges.
Severity ?
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| B&R Industrial Automation | B&R APROL |
Affected:
0 , ≤ <= R 4.2-07P3
(custom)
Affected: 0 , ≤ <= R 4.4-00P3 (custom) |
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:b_and_r_industrial_automotion:b_and_r_aprol:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "b_and_r_aprol",
"vendor": "b_and_r_industrial_automotion",
"versions": [
{
"lessThanOrEqual": "R 4.2-07P3",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThanOrEqual": "R 4.4-00P3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-5622",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-08-29T13:21:46.036564Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-08-29T13:29:24.311Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"modules": [
"AprolConfigureCCServices"
],
"product": "B\u0026R APROL",
"vendor": "B\u0026R Industrial Automation",
"versions": [
{
"lessThanOrEqual": "\u003c= R 4.2-07P3",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThanOrEqual": "\u003c= R 4.4-00P3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"datePublic": "2024-08-29T08:40:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "An untrusted search path vulnerability in the AprolConfigureCCServices of B\u0026amp;R APROL \u0026lt;= R 4.2.-07P3 and \u0026lt;= R 4.4-00P3 may allow an authenticated local attacker to execute arbitrary code with elevated privileges."
}
],
"value": "An untrusted search path vulnerability in the AprolConfigureCCServices of B\u0026R APROL \u003c= R 4.2.-07P3 and \u003c= R 4.4-00P3 may allow an authenticated local attacker to execute arbitrary code with elevated privileges."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "PRESENT",
"attackVector": "LOCAL",
"baseScore": 7.3,
"baseSeverity": "HIGH",
"privilegesRequired": "LOW",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:P/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-250",
"description": "CWE-250 Execution with Unnecessary Privileges",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-267",
"description": "CWE-267 Privilege Defined With Unsafe Actions",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-08-29T08:49:48.300Z",
"orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
"shortName": "ABB"
},
"references": [
{
"url": "https://www.br-automation.com/fileadmin/SA24P2014_Multiple_vulnerabilities_in_BR_APROL.pdf-367290ae.pdf"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Untrusted search path vulnerability in the AprolConfigureCCServices of B\u0026R APROL",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
"assignerShortName": "ABB",
"cveId": "CVE-2024-5622",
"datePublished": "2024-08-29T08:49:48.300Z",
"dateReserved": "2024-06-04T08:28:13.545Z",
"dateUpdated": "2024-08-29T13:29:24.311Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-0220 (GCVE-0-2024-0220)
Vulnerability from cvelistv5 – Published: 2024-02-22 10:15 – Updated: 2024-09-19 17:24
VLAI?
Summary
B&R Automation Studio Upgrade Service and B&R Technology Guarding use insufficient cryptography for communication to the upgrade and the licensing servers. A network-based attacker could exploit the vulnerability to execute arbitrary code on the products or sniff sensitive data.
Severity ?
8.3 (High)
CWE
Assigner
References
Impacted products
| Vendor | Product | Version | |||||||
|---|---|---|---|---|---|---|---|---|---|
| B&R Industrial Automation | Automation Studio |
Affected:
4.0 , < 4.6
(patch)
|
|||||||
|
|||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-01T17:41:15.976Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://www.br-automation.com/fileadmin/SA23P019_Automation_Studio_Upgrade_Service_uses_insufficient_encryption.pdf-1b3b181c.pdf"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"cpes": [
"cpe:2.3:a:br-automation:automation_studio:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "automation_studio",
"vendor": "br-automation",
"versions": [
{
"lessThan": "4.6",
"status": "affected",
"version": "4.0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-0220",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-02-22T16:23:26.378691Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-08-28T16:52:09.908Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"modules": [
"Upgrade Service"
],
"product": "Automation Studio",
"vendor": "B\u0026R Industrial Automation",
"versions": [
{
"lessThan": "4.6",
"status": "affected",
"version": "4.0",
"versionType": "patch"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Technology Guarding",
"vendor": "B\u0026R Industrial Automation",
"versions": [
{
"lessThan": "1.4.0",
"status": "affected",
"version": "1.0.0",
"versionType": "patch"
}
]
}
],
"datePublic": "2024-02-22T10:10:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "B\u0026amp;R Automation Studio Upgrade Service and B\u0026amp;R Technology Guarding use insufficient cryptography for communication to the upgrade and the licensing servers. A network-based attacker could exploit the vulnerability to execute arbitrary code on the products or sniff sensitive data.\n\n\u003cbr\u003e"
}
],
"value": "B\u0026R Automation Studio Upgrade Service and B\u0026R Technology Guarding use insufficient cryptography for communication to the upgrade and the licensing servers. A network-based attacker could exploit the vulnerability to execute arbitrary code on the products or sniff sensitive data."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.3,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:C/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-1240",
"description": "CWE-1240: Use of a Cryptographic Primitive with a Risky Implementation",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-319",
"description": "CWE-319 Cleartext Transmission of Sensitive Information",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-94",
"description": "CWE-94 Improper Control of Generation of Code (\u0027Code Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-09-19T17:24:51.723Z",
"orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
"shortName": "ABB"
},
"references": [
{
"url": "https://www.br-automation.com/fileadmin/SA23P019_Automation_Studio_Upgrade_Service_uses_insufficient_encryption.pdf-1b3b181c.pdf"
}
],
"source": {
"advisory": "2023-P019",
"discovery": "INTERNAL"
},
"title": "B\u0026R products use insufficient communication encryption",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
"assignerShortName": "ABB",
"cveId": "CVE-2024-0220",
"datePublished": "2024-02-22T10:15:44.750Z",
"dateReserved": "2024-01-03T15:46:41.224Z",
"dateUpdated": "2024-09-19T17:24:51.723Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-6028 (GCVE-0-2023-6028)
Vulnerability from cvelistv5 – Published: 2024-02-05 17:33 – Updated: 2024-08-02 08:21
VLAI?
Summary
A reflected
cross-site scripting (XSS) vulnerability exists in the SVG version of System
Diagnostics Manager of B&R Automation Runtime versions <= G4.93 that
enables a remote attacker to execute arbitrary JavaScript code in the context
of the attacked user’s browser session.
Severity ?
6.1 (Medium)
CWE
- CWE-79 - Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| B&R Industrial Automation | Automation Runtime |
Affected:
14.0 , < 14.93
(patch)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-6028",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-03-07T18:48:50.631233Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-06-04T17:17:03.877Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-02T08:21:17.060Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://www.br-automation.com/fileadmin/SA23P018_SDM_Web_interface_vulnerable_to_XSS-1d75bee8.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"modules": [
"SDM"
],
"product": "Automation Runtime",
"vendor": "B\u0026R Industrial Automation",
"versions": [
{
"lessThan": "14.93",
"status": "affected",
"version": "14.0",
"versionType": "patch"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eA reflected\ncross-site scripting (XSS) vulnerability exists in the SVG version of System\nDiagnostics Manager of B\u0026amp;R Automation Runtime versions \u0026lt;= G4.93 that\nenables a remote attacker to execute arbitrary JavaScript code in the context\nof the attacked user\u2019s browser session.\u003c/p\u003e\n\n\n\n\n\n"
}
],
"value": "A reflected\ncross-site scripting (XSS) vulnerability exists in the SVG version of System\nDiagnostics Manager of B\u0026R Automation Runtime versions \u003c= G4.93 that\nenables a remote attacker to execute arbitrary JavaScript code in the context\nof the attacked user\u2019s browser session.\n\n\n\n\n\n\n\n"
}
],
"impacts": [
{
"capecId": "CAPEC-63",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-63 Cross-Site Scripting (XSS)"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.1,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-79",
"description": "CWE-79 Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-02-06T13:54:25.416Z",
"orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
"shortName": "ABB"
},
"references": [
{
"url": "https://www.br-automation.com/fileadmin/SA23P018_SDM_Web_interface_vulnerable_to_XSS-1d75bee8.pdf"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "An update is available that resolves a vulnerability in the product versions listed above."
}
],
"value": "An update is available that resolves a vulnerability in the product versions listed above."
}
],
"source": {
"advisory": "SA23P018",
"discovery": "INTERNAL"
},
"title": "SDM Web interface vulnerable to XSS",
"workarounds": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\n\u003cp\u003eDo not use Hyperlinks provided by untrusted 3rd party to access the SDM. Hyperlinks may be provided via:\u003c/p\u003e\u003cp\u003e\u003c/p\u003e\u003cul\u003e\u003cli\u003eEmails from unknown users\u003c/li\u003e\u003cli\u003eSocial media channels\u003c/li\u003e\u003cli\u003eMessaging services\u003c/li\u003e\u003cli\u003eWebpages with comment functionality\u003c/li\u003e\u003cli\u003eQR Codes\u003c/li\u003e\u003c/ul\u003e\u003cp\u003e\u003c/p\u003e\u003cp\u003eThe use of external Web Application Firewalls (WAF) can mitigate attacks using reflected cross-site scripting.\u003c/p\u003e"
}
],
"value": "\nDo not use Hyperlinks provided by untrusted 3rd party to access the SDM. Hyperlinks may be provided via:\n\n\n\n * Emails from unknown users\n * Social media channels\n * Messaging services\n * Webpages with comment functionality\n * QR Codes\n\n\n\n\nThe use of external Web Application Firewalls (WAF) can mitigate attacks using reflected cross-site scripting.\n\n"
}
],
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
"assignerShortName": "ABB",
"cveId": "CVE-2023-6028",
"datePublished": "2024-02-05T17:33:34.785Z",
"dateReserved": "2023-11-08T10:17:50.175Z",
"dateUpdated": "2024-08-02T08:21:17.060Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-0323 (GCVE-0-2024-0323)
Vulnerability from cvelistv5 – Published: 2024-02-05 16:05 – Updated: 2024-09-06 07:21
VLAI?
Summary
The FTP server used on the B&R
Automation Runtime supports unsecure encryption mechanisms, such as SSLv3,
TLSv1.0 and TLS1.1. An network-based attacker can exploit the flaws to conduct
man-in-the-middle attacks or to decrypt communications between the affected product
clients.
Severity ?
9.8 (Critical)
CWE
- CWE-1240 - Use of a Cryptographic Primitive with a Risky Implementation
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| B&R Industrial Automation | Automation Runtime |
Affected:
14.0 , < 14.93
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-01T18:04:49.140Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://www.br-automation.com/fileadmin/SA23P004_FTP_uses_unsecure_encryption_mechanisms-f57c147c.pdf"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"cpes": [
"cpe:2.3:a:br-automation:automation_runtime:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "automation_runtime",
"vendor": "br-automation",
"versions": [
{
"lessThan": "14.93",
"status": "affected",
"version": "14.0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-0323",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-08-22T14:10:59.497846Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-08-22T14:16:16.093Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"modules": [
"SDM"
],
"product": "Automation Runtime",
"vendor": "B\u0026R Industrial Automation",
"versions": [
{
"lessThan": "14.93",
"status": "affected",
"version": "14.0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "The FTP server used on the B\u0026amp;R\nAutomation Runtime supports unsecure encryption mechanisms, such as SSLv3,\nTLSv1.0 and TLS1.1. An network-based attacker can exploit the flaws to conduct\nman-in-the-middle attacks or to decrypt communications between the affected product\nclients. \u0026nbsp;\n\n\u003cbr\u003e"
}
],
"value": "The FTP server used on the B\u0026R\nAutomation Runtime supports unsecure encryption mechanisms, such as SSLv3,\nTLSv1.0 and TLS1.1. An network-based attacker can exploit the flaws to conduct\nman-in-the-middle attacks or to decrypt communications between the affected product\nclients."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-1240",
"description": "CWE-1240: Use of a Cryptographic Primitive with a Risky Implementation",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-09-06T07:21:29.270Z",
"orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
"shortName": "ABB"
},
"references": [
{
"url": "https://www.br-automation.com/fileadmin/SA23P004_FTP_uses_unsecure_encryption_mechanisms-f57c147c.pdf"
}
],
"source": {
"advisory": "SA23P018",
"discovery": "INTERNAL"
},
"title": "FTP uses unsecure encryption mechanisms",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
"assignerShortName": "ABB",
"cveId": "CVE-2024-0323",
"datePublished": "2024-02-05T16:05:47.612Z",
"dateReserved": "2024-01-08T13:02:23.041Z",
"dateUpdated": "2024-09-06T07:21:29.270Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-22281 (GCVE-0-2021-22281)
Vulnerability from cvelistv5 – Published: 2024-02-02 07:24 – Updated: 2024-08-21 17:32
VLAI?
Summary
: Relative Path Traversal vulnerability in B&R Industrial Automation Automation Studio allows Relative Path Traversal.This issue affects Automation Studio: from 4.0 through 4.12.
Severity ?
6.3 (Medium)
CWE
- CWE-23 - Relative Path Traversal
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| B&R Industrial Automation | Automation Studio |
Affected:
4.0 , ≤ 4.12
(custom)
|
Credits
B&R would like to thank the following for working with us to help protect our customers: Mr. Mashav Sapir of Claroty, Mr. Andrew Hofmans
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T18:37:18.432Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://www.br-automation.com/fileadmin/2021-11_ZipSlip_Vulnerability_in_Automation_Studio_Project_Import-b90d2f42.pdf"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2021-22281",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-08-21T15:56:31.407839Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-08-21T17:32:38.731Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Automation Studio",
"vendor": "B\u0026R Industrial Automation",
"versions": [
{
"lessThanOrEqual": "4.12",
"status": "affected",
"version": "4.0",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "B\u0026R would like to thank the following for working with us to help protect our customers: Mr. Mashav Sapir of Claroty, Mr. Andrew Hofmans"
}
],
"datePublic": "2021-10-28T18:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": ": Relative Path Traversal vulnerability in B\u0026amp;R Industrial Automation Automation Studio allows Relative Path Traversal.\u003cp\u003eThis issue affects Automation Studio: from 4.0 through 4.12.\u003c/p\u003e"
}
],
"value": ": Relative Path Traversal vulnerability in B\u0026R Industrial Automation Automation Studio allows Relative Path Traversal.This issue affects Automation Studio: from 4.0 through 4.12.\n\n"
}
],
"impacts": [
{
"capecId": "CAPEC-139",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-139 Relative Path Traversal"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "NONE",
"baseScore": 6.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:C/C:N/I:H/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-23",
"description": "CWE-23: Relative Path Traversal",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-02-02T11:25:16.360Z",
"orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
"shortName": "ABB"
},
"references": [
{
"url": "https://www.br-automation.com/fileadmin/2021-11_ZipSlip_Vulnerability_in_Automation_Studio_Project_Import-b90d2f42.pdf"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Zip Slip Vulnerability in B\u0026R Automation Studio Project Import",
"workarounds": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\nB\u0026amp;R recommends the following specific workarounds and mitigations:\nOpen only B\u0026amp;R Automation Studio project files from trusted source.\nUse encrypted export of B\u0026amp;R Automation Studio project files, thus only allowing access to legitimate \nusers.\nProtect locations where B\u0026amp;R Automation Studio projects are stored from unauthorized access. This \nincludes PLCs, when using the feature to back up project source files on target.\nDo not run B\u0026amp;R Automation Studio in elevated mode.\nMake sure, that Windows User Access Control (UAC) is enabled.\nVerify integrity of B\u0026amp;R Automation Studio project files, which are exchanged via potentially insecure \nchannels\nIn general, B\u0026amp;R recommends implementing the Cyber Security guidelines\n\n\u003cbr\u003e"
}
],
"value": "\nB\u0026R recommends the following specific workarounds and mitigations:\nOpen only B\u0026R Automation Studio project files from trusted source.\nUse encrypted export of B\u0026R Automation Studio project files, thus only allowing access to legitimate \nusers.\nProtect locations where B\u0026R Automation Studio projects are stored from unauthorized access. This \nincludes PLCs, when using the feature to back up project source files on target.\nDo not run B\u0026R Automation Studio in elevated mode.\nMake sure, that Windows User Access Control (UAC) is enabled.\nVerify integrity of B\u0026R Automation Studio project files, which are exchanged via potentially insecure \nchannels\nIn general, B\u0026R recommends implementing the Cyber Security guidelines\n\n\n"
}
],
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
"assignerShortName": "ABB",
"cveId": "CVE-2021-22281",
"datePublished": "2024-02-02T07:24:29.599Z",
"dateReserved": "2021-01-05T17:31:49.080Z",
"dateUpdated": "2024-08-21T17:32:38.731Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-24682 (GCVE-0-2020-24682)
Vulnerability from cvelistv5 – Published: 2024-02-02 07:11 – Updated: 2025-06-17 21:29
VLAI?
Summary
Unquoted Search Path or Element vulnerability in B&R Industrial Automation Automation Studio, B&R Industrial Automation NET/PVI allows Target Programs with Elevated Privileges.This issue affects Automation Studio: from 4.0 through 4.6, from 4.7.0 before 4.7.7 SP, from 4.8.0 before 4.8.6 SP, from 4.9.0 before 4.9.4 SP; NET/PVI: from 4.0 through 4.6, from 4.7.0 before 4.7.7, from 4.8.0 before 4.8.6, from 4.9.0 before 4.9.4.
Severity ?
7.2 (High)
CWE
- CWE-428 - Unquoted Search Path or Element
Assigner
References
Impacted products
| Vendor | Product | Version | |||||||
|---|---|---|---|---|---|---|---|---|---|
| B&R Industrial Automation | Automation Studio |
Affected:
4.0 , ≤ 4.6
(custom)
Affected: 4.7.0 , < 4.7.7 SP (custom) Affected: 4.8.0 , < 4.8.6 SP (custom) Affected: 4.9.0 , < 4.9.4 SP (custom) |
|||||||
|
|||||||||
Credits
B&R would like to thank the following for working with us to help protect our customers: Mr. Andrew Hofmans
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T15:19:09.304Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://www.br-automation.com/fileadmin/2021-14-BR-AS-NET-PVI-Service-Issues-c3710fbf.pdf"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2020-24682",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-02-02T14:19:51.368303Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-06-17T21:29:22.845Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Automation Studio",
"vendor": "B\u0026R Industrial Automation",
"versions": [
{
"lessThanOrEqual": "4.6",
"status": "affected",
"version": "4.0",
"versionType": "custom"
},
{
"lessThan": "4.7.7 SP",
"status": "affected",
"version": "4.7.0",
"versionType": "custom"
},
{
"lessThan": "4.8.6 SP",
"status": "affected",
"version": "4.8.0",
"versionType": "custom"
},
{
"lessThan": "4.9.4 SP",
"status": "affected",
"version": "4.9.0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "NET/PVI",
"vendor": "B\u0026R Industrial Automation",
"versions": [
{
"lessThanOrEqual": "4.6",
"status": "affected",
"version": "4.0",
"versionType": "custom"
},
{
"lessThan": "4.7.7",
"status": "affected",
"version": "4.7.0",
"versionType": "custom"
},
{
"lessThan": "4.8.6",
"status": "affected",
"version": "4.8.0",
"versionType": "custom"
},
{
"lessThan": "4.9.4",
"status": "affected",
"version": "4.9.0",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "B\u0026R would like to thank the following for working with us to help protect our customers: Mr. Andrew Hofmans"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Unquoted Search Path or Element vulnerability in B\u0026amp;R Industrial Automation Automation Studio, B\u0026amp;R Industrial Automation NET/PVI allows Target Programs with Elevated Privileges.\u003cp\u003eThis issue affects Automation Studio: from 4.0 through 4.6, from 4.7.0 before 4.7.7 SP, from 4.8.0 before 4.8.6 SP, from 4.9.0 before 4.9.4 SP; NET/PVI: from 4.0 through 4.6, from 4.7.0 before 4.7.7, from 4.8.0 before 4.8.6, from 4.9.0 before 4.9.4.\u003c/p\u003e"
}
],
"value": "Unquoted Search Path or Element vulnerability in B\u0026R Industrial Automation Automation Studio, B\u0026R Industrial Automation NET/PVI allows Target Programs with Elevated Privileges.This issue affects Automation Studio: from 4.0 through 4.6, from 4.7.0 before 4.7.7 SP, from 4.8.0 before 4.8.6 SP, from 4.9.0 before 4.9.4 SP; NET/PVI: from 4.0 through 4.6, from 4.7.0 before 4.7.7, from 4.8.0 before 4.8.6, from 4.9.0 before 4.9.4.\n\n"
}
],
"impacts": [
{
"capecId": "CAPEC-69",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-69 Target Programs with Elevated Privileges"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:R/S:C/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-428",
"description": "CWE-428 Unquoted Search Path or Element",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-02-02T11:30:17.773Z",
"orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
"shortName": "ABB"
},
"references": [
{
"url": "https://www.br-automation.com/fileadmin/2021-14-BR-AS-NET-PVI-Service-Issues-c3710fbf.pdf"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Automation Studio and PVI Multiple unquoted service path vulnerabilities",
"workarounds": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\n\n\nB\u0026amp;R has identified the following specific workarounds and mitigations.\nUsers of B\u0026amp;R Automation Studio and PVI may manually reconfigure the service paths and enclose them \nin quotes.\nAdditionally, it is recommended to limit access to the workstation running B\u0026amp;R Automation Studio and PVI \nto authorized users\n\n\n\n\u003cbr\u003e"
}
],
"value": "\n\n\nB\u0026R has identified the following specific workarounds and mitigations.\nUsers of B\u0026R Automation Studio and PVI may manually reconfigure the service paths and enclose them \nin quotes.\nAdditionally, it is recommended to limit access to the workstation running B\u0026R Automation Studio and PVI \nto authorized users\n\n\n\n\n"
}
],
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
"assignerShortName": "ABB",
"cveId": "CVE-2020-24682",
"datePublished": "2024-02-02T07:11:44.086Z",
"dateReserved": "2020-08-26T00:00:00.000Z",
"dateUpdated": "2025-06-17T21:29:22.845Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-24681 (GCVE-0-2020-24681)
Vulnerability from cvelistv5 – Published: 2024-02-02 06:58 – Updated: 2025-05-09 17:52
VLAI?
Summary
Incorrect Permission Assignment for Critical Resource vulnerability in B&R Industrial Automation Automation Studio allows Privilege Escalation.This issue affects Automation Studio: from 4.6.0 through 4.6.X, from 4.7.0 before 4.7.7 SP, from 4.8.0 before 4.8.6 SP, from 4.9.0 before 4.9.4 SP.
Severity ?
8.2 (High)
CWE
- CWE-732 - Incorrect Permission Assignment for Critical Resource
Assigner
References
Impacted products
| Vendor | Product | Version | |||||||
|---|---|---|---|---|---|---|---|---|---|
| B&R Industrial Automation | Automation Studio |
Affected:
4.6.0 , ≤ 4.6.x
(custom)
Affected: 4.7.0 , < 4.7.7 SP (custom) Affected: 4.8.0 , < 4.8.6 SP (custom) Affected: 4.9.0 , < 4.9.4 SP (custom) |
|||||||
|
|||||||||
Credits
B&R would like to thank the following for working with us to help protect our customers: Mr. Andrew Hofmans
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T15:19:09.083Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://www.br-automation.com/fileadmin/2021-14-BR-AS-NET-PVI-Service-Issues-c3710fbf.pdf"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2020-24681",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-02-02T17:22:16.797450Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-05-09T17:52:17.145Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Automation Studio",
"vendor": "B\u0026R Industrial Automation",
"versions": [
{
"lessThanOrEqual": "4.6.x",
"status": "affected",
"version": "4.6.0",
"versionType": "custom"
},
{
"lessThan": "4.7.7 SP",
"status": "affected",
"version": "4.7.0",
"versionType": "custom"
},
{
"lessThan": "4.8.6 SP",
"status": "affected",
"version": "4.8.0",
"versionType": "custom"
},
{
"lessThan": "4.9.4 SP",
"status": "affected",
"version": "4.9.0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "NET/PVI",
"vendor": "B\u0026R Industrial Automation",
"versions": [
{
"lessThanOrEqual": "4.6.x",
"status": "affected",
"version": "4.6.0",
"versionType": "custom"
},
{
"lessThan": "4.7.7",
"status": "affected",
"version": "4.7.0",
"versionType": "custom"
},
{
"lessThan": "4.8.6",
"status": "affected",
"version": "4.8.0",
"versionType": "custom"
},
{
"lessThan": "4.9.4",
"status": "affected",
"version": "4.9.0",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "B\u0026R would like to thank the following for working with us to help protect our customers: Mr. Andrew Hofmans"
}
],
"datePublic": "2021-11-29T18:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Incorrect Permission Assignment for Critical Resource vulnerability in B\u0026amp;R Industrial Automation Automation Studio allows Privilege Escalation.\u003cp\u003eThis issue affects Automation Studio: from 4.6.0 through 4.6.X, from 4.7.0 before 4.7.7 SP, from 4.8.0 before 4.8.6 SP, from 4.9.0 before 4.9.4 SP.\u003c/p\u003e"
}
],
"value": "Incorrect Permission Assignment for Critical Resource vulnerability in B\u0026R Industrial Automation Automation Studio allows Privilege Escalation.This issue affects Automation Studio: from 4.6.0 through 4.6.X, from 4.7.0 before 4.7.7 SP, from 4.8.0 before 4.8.6 SP, from 4.9.0 before 4.9.4 SP.\n\n"
}
],
"impacts": [
{
"capecId": "CAPEC-233",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-233 Privilege Escalation"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 8.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:C/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-732",
"description": "CWE-732 Incorrect Permission Assignment for Critical Resource",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-02-02T06:58:24.173Z",
"orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
"shortName": "ABB"
},
"references": [
{
"url": "https://www.br-automation.com/fileadmin/2021-14-BR-AS-NET-PVI-Service-Issues-c3710fbf.pdf"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Automation Studio and PVI Multiple incorrect permission assignments for services",
"workarounds": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\nB\u0026amp;R has identified the following specific workarounds and mitigations.\nUsers of B\u0026amp;R Automation Studio and PVI may manually reconfigure permission settings on these \nservices to allow modification only for privileged users.\nAdditionally, it is recommended to limit access to the workstation running B\u0026amp;R Automation Studio and PVI \nto authorized users.\n\n\n\u003cbr\u003e"
}
],
"value": "\nB\u0026R has identified the following specific workarounds and mitigations.\nUsers of B\u0026R Automation Studio and PVI may manually reconfigure permission settings on these \nservices to allow modification only for privileged users.\nAdditionally, it is recommended to limit access to the workstation running B\u0026R Automation Studio and PVI \nto authorized users.\n\n\n\n"
}
],
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
"assignerShortName": "ABB",
"cveId": "CVE-2020-24681",
"datePublished": "2024-02-02T06:58:24.173Z",
"dateReserved": "2020-08-26T00:00:00.000Z",
"dateUpdated": "2025-05-09T17:52:17.145Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-22282 (GCVE-0-2021-22282)
Vulnerability from cvelistv5 – Published: 2024-02-02 06:38 – Updated: 2025-06-17 21:29
VLAI?
Summary
Improper Control of Generation of Code ('Code Injection') vulnerability in B&R Industrial Automation Automation Studio allows Local Execution of Code.This issue affects Automation Studio: from 4.0 through 4.12.
Severity ?
8.3 (High)
CWE
- CWE-94 - Improper Control of Generation of Code ('Code Injection')
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| B&R Industrial Automation | Automation Studio |
Affected:
4.0 , ≤ 4.12
(custom)
|
Credits
B&R would like to thank the following for working with us to help protect our customers: Mr. Mashav Sapir of Claroty, Mr. Andrew Hofmans
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T18:37:18.516Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://www.br-automation.com/fileadmin/2021-12_RCE_Vulnerability_in_BnR_Automation_Studio-1b993aeb.pdf"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2021-22282",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-03-14T21:13:25.788287Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-06-17T21:29:23.035Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Automation Studio",
"vendor": "B\u0026R Industrial Automation",
"versions": [
{
"lessThanOrEqual": "4.12",
"status": "affected",
"version": "4.0",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "B\u0026R would like to thank the following for working with us to help protect our customers: Mr. Mashav Sapir of Claroty, Mr. Andrew Hofmans"
}
],
"datePublic": "2021-10-28T18:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Improper Control of Generation of Code (\u0027Code Injection\u0027) vulnerability in B\u0026amp;R Industrial Automation Automation Studio allows Local Execution of Code.\u003cp\u003eThis issue affects Automation Studio: from 4.0 through 4.12.\u003c/p\u003e"
}
],
"value": "Improper Control of Generation of Code (\u0027Code Injection\u0027) vulnerability in B\u0026R Industrial Automation Automation Studio allows Local Execution of Code.This issue affects Automation Studio: from 4.0 through 4.12.\n\n"
}
],
"impacts": [
{
"capecId": "CAPEC-549",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-549 Local Execution of Code"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.3,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:C/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-94",
"description": "CWE-94 Improper Control of Generation of Code (\u0027Code Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-02-02T11:25:49.556Z",
"orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
"shortName": "ABB"
},
"references": [
{
"url": "https://www.br-automation.com/fileadmin/2021-12_RCE_Vulnerability_in_BnR_Automation_Studio-1b993aeb.pdf"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "RCE in B\u0026R Automation Studio with crafted project files",
"workarounds": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\nB\u0026amp;R recommends the following specific workarounds and mitigations:\nOpen only B\u0026amp;R Automation Studio project files from trusted source.\nProtect locations where B\u0026amp;R Automation Studio projects are stored from unauthorized access. This \nincludes PLCs, when using the feature to back up project source files on target.\nDo not run B\u0026amp;R Automation Studio in elevated mode.\nVerify integrity of B\u0026amp;R Automation Studio project files, which are exchanged via potentially insecure \nchannels.\nMake sure, that Windows User Access Control (UAC) is enabled.\nIn general, B\u0026amp;R recommends implementing the Cyber Security guidelines.\n\n\u003cbr\u003e"
}
],
"value": "\nB\u0026R recommends the following specific workarounds and mitigations:\nOpen only B\u0026R Automation Studio project files from trusted source.\nProtect locations where B\u0026R Automation Studio projects are stored from unauthorized access. This \nincludes PLCs, when using the feature to back up project source files on target.\nDo not run B\u0026R Automation Studio in elevated mode.\nVerify integrity of B\u0026R Automation Studio project files, which are exchanged via potentially insecure \nchannels.\nMake sure, that Windows User Access Control (UAC) is enabled.\nIn general, B\u0026R recommends implementing the Cyber Security guidelines.\n\n\n"
}
],
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
"assignerShortName": "ABB",
"cveId": "CVE-2021-22282",
"datePublished": "2024-02-02T06:38:32.358Z",
"dateReserved": "2021-01-05T17:31:49.080Z",
"dateUpdated": "2025-06-17T21:29:23.035Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-3242 (GCVE-0-2023-3242)
Vulnerability from cvelistv5 – Published: 2023-07-26 17:36 – Updated: 2024-10-23 15:31
VLAI?
Summary
Improper initialization implementation in Portmapper used in B&R Industrial Automation Automation Runtime <G4.93 allows unauthenticated network-based attackers to cause permanent denial-of-service conditions.
Severity ?
8.6 (High)
CWE
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| B&R Industrial Automation | B&R Automation Runtime |
Affected:
<G4.93
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T06:48:08.336Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://www.br-automation.com/downloads_br_productcatalogue/assets/1689787619746-en-original-1.0.pdf"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-3242",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-23T15:31:14.569229Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-10-23T15:31:51.096Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "B\u0026R Automation Runtime",
"vendor": "B\u0026R Industrial Automation",
"versions": [
{
"status": "affected",
"version": "\u003cG4.93"
}
]
}
],
"datePublic": "2023-07-25T22:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\nImproper initialization implementation in Portmapper used in B\u0026amp;R Industrial Automation Automation Runtime \u0026lt;G4.93 allows unauthenticated network-based attackers to cause permanent denial-of-service conditions.\n\n"
}
],
"value": "Improper initialization implementation in Portmapper used in B\u0026R Industrial Automation Automation Runtime \u003cG4.93 allows unauthenticated network-based attackers to cause permanent denial-of-service conditions."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.6,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:N/I:N/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-770",
"description": "CWE-770 Allocation of Resources Without Limits or Throttling",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-665",
"description": "CWE-665 Improper Initialization",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-05-27T07:12:22.331Z",
"orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
"shortName": "ABB"
},
"references": [
{
"url": "https://www.br-automation.com/downloads_br_productcatalogue/assets/1689787619746-en-original-1.0.pdf"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
"assignerShortName": "ABB",
"cveId": "CVE-2023-3242",
"datePublished": "2023-07-26T17:36:18.417Z",
"dateReserved": "2023-06-14T11:28:13.641Z",
"dateUpdated": "2024-10-23T15:31:51.096Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-1617 (GCVE-0-2023-1617)
Vulnerability from cvelistv5 – Published: 2023-04-14 11:48 – Updated: 2025-02-06 19:48
VLAI?
Summary
Improper Authentication vulnerability in B&R Industrial Automation B&R VC4 (VNC-Server modules). This vulnerability may allow an unauthenticated network-based attacker to bypass the authentication mechanism of the VC4 visualization on affected devices. The impact of this vulnerability depends on the functionality provided in the visualization.
This issue affects B&R VC4: from 3.* through 3.96.7, from 4.0* through 4.06.7, from 4.1* through 4.16.3, from 4.2* through 4.26.8, from 4.3* through 4.34.6, from 4.4* through 4.45.1, from 4.5* through 4.45.3, from 4.7* through 4.72.9.
Severity ?
9.8 (Critical)
CWE
- CWE-287 - Improper Authentication
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| B&R Industrial Automation | B&R VC4 |
Affected:
3.* , ≤ 3.96.7
(custom)
Affected: 4.0* , ≤ 4.06.7 (custom) Affected: 4.1* , ≤ 4.16.3 (custom) Affected: 4.2* , ≤ 4.26.8 (custom) Affected: 4.3* , ≤ 4.34.6 (custom) Affected: 4.4* , ≤ 4.45.1 (custom) Affected: 4.5* , ≤ 4.45.3 (custom) Affected: 4.7* , ≤ 4.72.9 (custom) |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T05:57:24.043Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://www.br-automation.com/downloads_br_productcatalogue/assets/1681046878970-en-original-1.0.pdf"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-1617",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-02-06T19:48:02.341552Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-02-06T19:48:05.890Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"modules": [
"VNC-Server"
],
"product": "B\u0026R VC4",
"vendor": "B\u0026R Industrial Automation",
"versions": [
{
"lessThanOrEqual": "3.96.7",
"status": "affected",
"version": "3.*",
"versionType": "custom"
},
{
"lessThanOrEqual": "4.06.7",
"status": "affected",
"version": "4.0*",
"versionType": "custom"
},
{
"lessThanOrEqual": "4.16.3",
"status": "affected",
"version": "4.1*",
"versionType": "custom"
},
{
"lessThanOrEqual": "4.26.8",
"status": "affected",
"version": "4.2*",
"versionType": "custom"
},
{
"lessThanOrEqual": "4.34.6",
"status": "affected",
"version": "4.3*",
"versionType": "custom"
},
{
"lessThanOrEqual": "4.45.1",
"status": "affected",
"version": "4.4*",
"versionType": "custom"
},
{
"lessThanOrEqual": "4.45.3",
"status": "affected",
"version": "4.5*",
"versionType": "custom"
},
{
"lessThanOrEqual": "4.72.9",
"status": "affected",
"version": "4.7*",
"versionType": "custom"
}
]
}
],
"datePublic": "2023-04-13T18:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Improper Authentication vulnerability in B\u0026amp;R Industrial Automation B\u0026amp;R VC4 (VNC-Server modules).\u0026nbsp; This vulnerability may allow an unauthenticated network-based attacker to bypass the authentication mechanism of the VC4 visualization on affected devices. The impact of this vulnerability depends on the functionality provided in the visualization.\u003cbr\u003e\u003cp\u003eThis issue affects B\u0026amp;R VC4: from 3.* through 3.96.7, from 4.0* through 4.06.7, from 4.1* through 4.16.3, from 4.2* through 4.26.8, from 4.3* through 4.34.6, from 4.4* through 4.45.1, from 4.5* through 4.45.3, from 4.7* through 4.72.9.\u003c/p\u003e"
}
],
"value": "Improper Authentication vulnerability in B\u0026R Industrial Automation B\u0026R VC4 (VNC-Server modules).\u00a0 This vulnerability may allow an unauthenticated network-based attacker to bypass the authentication mechanism of the VC4 visualization on affected devices. The impact of this vulnerability depends on the functionality provided in the visualization.\nThis issue affects B\u0026R VC4: from 3.* through 3.96.7, from 4.0* through 4.06.7, from 4.1* through 4.16.3, from 4.2* through 4.26.8, from 4.3* through 4.34.6, from 4.4* through 4.45.1, from 4.5* through 4.45.3, from 4.7* through 4.72.9.\n\n"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-287",
"description": "CWE-287 Improper Authentication",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-04-14T11:48:53.396Z",
"orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
"shortName": "ABB"
},
"references": [
{
"url": "https://www.br-automation.com/downloads_br_productcatalogue/assets/1681046878970-en-original-1.0.pdf"
}
],
"source": {
"discovery": "INTERNAL"
},
"title": "Improper Authentication Mechanism in B\u0026R VC4 Visualization",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
"assignerShortName": "ABB",
"cveId": "CVE-2023-1617",
"datePublished": "2023-04-14T11:48:53.396Z",
"dateReserved": "2023-03-24T07:13:36.844Z",
"dateUpdated": "2025-02-06T19:48:05.890Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-4286 (GCVE-0-2022-4286)
Vulnerability from cvelistv5 – Published: 2023-02-14 14:25 – Updated: 2025-03-20 14:07
VLAI?
Summary
A reflected cross-site scripting (XSS) vulnerability exists in System Diagnostics Manager of B&R Automation Runtime versions >=3.00 and <=C4.93 that enables a remote attacker to execute arbitrary JavaScript in the context of the users browser session.
Severity ?
6.1 (Medium)
CWE
- CWE-79 - Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| B&R Industrial Automation | B&R Automation Runtime |
Affected:
>=3.00 , ≤ C4.93
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T01:34:50.116Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://www.br-automation.com/downloads_br_productcatalogue/assets/1675607299099-en-original-1.0.pdf"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-4286",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-03-20T14:07:48.804634Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-03-20T14:07:56.101Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"modules": [
"System Diagnostics Manager"
],
"product": "B\u0026R Automation Runtime",
"vendor": "B\u0026R Industrial Automation",
"versions": [
{
"lessThanOrEqual": "C4.93",
"status": "affected",
"version": "\u003e=3.00",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eA reflected cross-site scripting (XSS) vulnerability exists in System Diagnostics Manager of B\u0026amp;R Automation Runtime versions \u0026gt;=3.00 and \u0026lt;=C4.93 that enables a remote attacker to execute arbitrary JavaScript in the context of the users browser session.\u003c/span\u003e\n\n"
}
],
"value": "\nA reflected cross-site scripting (XSS) vulnerability exists in System Diagnostics Manager of B\u0026R Automation Runtime versions \u003e=3.00 and \u003c=C4.93 that enables a remote attacker to execute arbitrary JavaScript in the context of the users browser session.\n\n"
}
],
"impacts": [
{
"capecId": "CAPEC-591",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-591 Reflected XSS"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.1,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-79",
"description": "CWE-79 Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-02-15T02:14:49.612Z",
"orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
"shortName": "ABB"
},
"references": [
{
"url": "https://www.br-automation.com/downloads_br_productcatalogue/assets/1675607299099-en-original-1.0.pdf"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Reflected Cross-Site Scripting Vulnerabilities in Automation Runtime",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
"assignerShortName": "ABB",
"cveId": "CVE-2022-4286",
"datePublished": "2023-02-14T14:25:37.538Z",
"dateReserved": "2022-12-05T12:14:29.593Z",
"dateUpdated": "2025-03-20T14:07:56.101Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-43765 (GCVE-0-2022-43765)
Vulnerability from cvelistv5 – Published: 2023-02-08 10:17 – Updated: 2025-03-25 13:58
VLAI?
Summary
B&R APROL versions < R 4.2-07 doesn’t process correctly specially
formatted data packages sent to port 55502/tcp, which may allow a network based
attacker to cause an application Denial-of-Service.
Severity ?
7.5 (High)
CWE
- CWE-252 - Unchecked Return Value
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| B&R Industrial Automation | B&R APROL |
Affected:
< R 4.2-07
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T13:40:06.375Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://www.br-automation.com/downloads_br_productcatalogue/assets/1674823095245-en-original-1.0.pdf"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-43765",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-03-25T13:57:56.287641Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-03-25T13:58:06.196Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "B\u0026R APROL",
"vendor": "B\u0026R Industrial Automation",
"versions": [
{
"status": "affected",
"version": "\u003c R 4.2-07"
}
]
}
],
"datePublic": "2023-01-30T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eB\u0026amp;R APROL versions \u0026lt; R 4.2-07 doesn\u2019t process correctly specially\nformatted data packages sent to port 55502/tcp, which may allow a network based\nattacker to cause an application Denial-of-Service.\u003c/p\u003e\n\n\n\n\n\n"
}
],
"value": "B\u0026R APROL versions \u003c R 4.2-07 doesn\u2019t process correctly specially\nformatted data packages sent to port 55502/tcp, which may allow a network based\nattacker to cause an application Denial-of-Service.\n\n\n\n\n\n\n\n"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-252",
"description": "CWE-252: Unchecked Return Value",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-02-08T10:17:07.894Z",
"orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
"shortName": "ABB"
},
"references": [
{
"url": "https://www.br-automation.com/downloads_br_productcatalogue/assets/1674823095245-en-original-1.0.pdf"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "DoS in APROLs Tbase server",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
"assignerShortName": "ABB",
"cveId": "CVE-2022-43765",
"datePublished": "2023-02-08T10:17:07.894Z",
"dateReserved": "2022-10-26T07:17:06.425Z",
"dateUpdated": "2025-03-25T13:58:06.196Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-43764 (GCVE-0-2022-43764)
Vulnerability from cvelistv5 – Published: 2023-02-08 10:12 – Updated: 2025-03-25 13:58
VLAI?
Summary
Insufficient validation of input parameters when
changing configuration on Tbase server in B&R APROL versions < R 4.2-07 could result in buffer
overflow. This may lead to Denial-of-Service conditions or execution of
arbitrary code.
Severity ?
9.8 (Critical)
CWE
- CWE-121 - Stack-based Buffer Overflow
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| B&R Industrial Automation | B&R APROL |
Affected:
< R 4.2-07
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T13:40:06.235Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://www.br-automation.com/downloads_br_productcatalogue/assets/1674823095245-en-original-1.0.pdf"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-43764",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-03-25T13:58:38.119194Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-03-25T13:58:51.605Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "B\u0026R APROL",
"vendor": "B\u0026R Industrial Automation",
"versions": [
{
"status": "affected",
"version": "\u003c R 4.2-07"
}
]
}
],
"datePublic": "2023-01-30T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eInsufficient validation of input parameters when\nchanging configuration on Tbase server in B\u0026amp;R APROL versions\u0026nbsp;\u0026lt; R 4.2-07 could result in buffer\noverflow. This may lead to Denial-of-Service conditions or execution of\narbitrary code.\u003c/p\u003e\n\n\n\n\n\n"
}
],
"value": "Insufficient validation of input parameters when\nchanging configuration on Tbase server in B\u0026R APROL versions\u00a0\u003c R 4.2-07 could result in buffer\noverflow. This may lead to Denial-of-Service conditions or execution of\narbitrary code.\n\n\n\n\n\n\n\n"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121: Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-02-08T10:12:50.627Z",
"orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
"shortName": "ABB"
},
"references": [
{
"url": "https://www.br-automation.com/downloads_br_productcatalogue/assets/1674823095245-en-original-1.0.pdf"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Buffer overflow when changing configuration on Tbase Server",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
"assignerShortName": "ABB",
"cveId": "CVE-2022-43764",
"datePublished": "2023-02-08T10:12:50.627Z",
"dateReserved": "2022-10-26T07:17:06.425Z",
"dateUpdated": "2025-03-25T13:58:51.605Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-43763 (GCVE-0-2022-43763)
Vulnerability from cvelistv5 – Published: 2023-02-08 10:11 – Updated: 2025-03-25 13:59
VLAI?
Summary
Insufficient check of preconditions could lead
to Denial of Service conditions when calling commands on the Tbase server of B&R APROL versions < R 4.2-07.
Severity ?
7.5 (High)
CWE
- CWE-252 - Unchecked Return Value
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| B&R Industrial Automation | B&R APROL |
Affected:
< R 4.2-07
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T13:40:06.446Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://www.br-automation.com/downloads_br_productcatalogue/assets/1674823095245-en-original-1.0.pdf"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-43763",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-03-25T13:59:16.479708Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-03-25T13:59:26.651Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "B\u0026R APROL",
"vendor": "B\u0026R Industrial Automation",
"versions": [
{
"status": "affected",
"version": "\u003c R 4.2-07"
}
]
}
],
"datePublic": "2023-01-30T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eInsufficient check of preconditions could lead\nto Denial of Service conditions when calling commands on the Tbase server of B\u0026amp;R APROL versions\u0026nbsp;\u0026lt; R 4.2-07.\u003c/p\u003e\n\n\n\n\n\n"
}
],
"value": "Insufficient check of preconditions could lead\nto Denial of Service conditions when calling commands on the Tbase server of B\u0026R APROL versions\u00a0\u003c R 4.2-07.\n\n\n\n\n\n\n\n"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-252",
"description": "CWE-252: Unchecked Return Value",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-02-08T10:11:09.261Z",
"orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
"shortName": "ABB"
},
"references": [
{
"url": "https://www.br-automation.com/downloads_br_productcatalogue/assets/1674823095245-en-original-1.0.pdf"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Lack of checking preconditions in APROL ",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
"assignerShortName": "ABB",
"cveId": "CVE-2022-43763",
"datePublished": "2023-02-08T10:11:09.261Z",
"dateReserved": "2022-10-26T07:17:06.425Z",
"dateUpdated": "2025-03-25T13:59:26.651Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-43762 (GCVE-0-2022-43762)
Vulnerability from cvelistv5 – Published: 2023-02-08 10:06 – Updated: 2025-03-25 14:00
VLAI?
Summary
Lack of verification in B&R APROL
Tbase server versions < R 4.2-07 may lead to memory leaks when receiving messages
Severity ?
7.5 (High)
CWE
- CWE-119 - Improper Restriction of Operations within the Bounds of a Memory Buffer
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| B&R Industrial Automation | B&R APROL |
Affected:
< R 4.2-07
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T13:40:06.241Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://www.br-automation.com/downloads_br_productcatalogue/assets/1674823095245-en-original-1.0.pdf"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-43762",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-03-25T14:00:04.398182Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-03-25T14:00:12.544Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "B\u0026R APROL",
"vendor": "B\u0026R Industrial Automation",
"versions": [
{
"status": "affected",
"version": "\u003c R 4.2-07"
}
]
}
],
"datePublic": "2023-01-30T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u0026nbsp;Lack of verification in B\u0026amp;R APROL\nTbase server versions\u0026nbsp;\u0026lt; R 4.2-07 may lead to memory leaks when receiving messages\n\n\n\n"
}
],
"value": "\u00a0Lack of verification in B\u0026R APROL\nTbase server versions\u00a0\u003c R 4.2-07 may lead to memory leaks when receiving messages\n\n\n\n"
}
],
"impacts": [
{
"capecId": "CAPEC-242",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-242 Code Injection"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-02-08T10:06:06.480Z",
"orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
"shortName": "ABB"
},
"references": [
{
"url": "https://www.br-automation.com/downloads_br_productcatalogue/assets/1674823095245-en-original-1.0.pdf"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Memory leak when receiving messages in APROL Tbase server",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
"assignerShortName": "ABB",
"cveId": "CVE-2022-43762",
"datePublished": "2023-02-08T10:06:06.480Z",
"dateReserved": "2022-10-26T07:17:06.425Z",
"dateUpdated": "2025-03-25T14:00:12.544Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-43761 (GCVE-0-2022-43761)
Vulnerability from cvelistv5 – Published: 2023-02-08 09:33 – Updated: 2025-03-25 13:54
VLAI?
Summary
Missing authentication when creating and
managing the B&R APROL database in versions < R 4.2-07
allows reading and changing the system configuration.
Severity ?
9.4 (Critical)
CWE
- CWE-306 - Missing Authentication for Critical Function
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| B&R Industrial Automation | B&R APROL |
Affected:
< R 4.2-07
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T13:40:06.403Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://www.br-automation.com/downloads_br_productcatalogue/assets/1674823095245-en-original-1.0.pdf"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-43761",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-03-25T13:54:11.275487Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-03-25T13:54:18.752Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "B\u0026R APROL",
"vendor": "B\u0026R Industrial Automation",
"versions": [
{
"status": "affected",
"version": "\u003c R 4.2-07"
}
]
}
],
"datePublic": "2023-01-29T18:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eMissing authentication when creating and\nmanaging the B\u0026amp;R APROL database in versions \u0026lt;\u0026nbsp;R 4.2-07\n\n\n\nallows reading and changing the system configuration.\u0026nbsp;\u003c/p\u003e\n\n\n\n\n\n"
}
],
"value": "Missing authentication when creating and\nmanaging the B\u0026R APROL database in versions \u003c\u00a0R 4.2-07\n\n\n\nallows reading and changing the system configuration.\u00a0\n\n\n\n\n\n\n\n"
}
],
"impacts": [
{
"capecId": "CAPEC-176",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-176 Configuration/Environment Manipulation"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 9.4,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:L",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-306",
"description": "CWE-306 Missing Authentication for Critical Function",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-02-24T11:33:46.477Z",
"orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
"shortName": "ABB"
},
"references": [
{
"url": "https://www.br-automation.com/downloads_br_productcatalogue/assets/1674823095245-en-original-1.0.pdf"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Lack of authentication when managing APROL database",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
"assignerShortName": "ABB",
"cveId": "CVE-2022-43761",
"datePublished": "2023-02-08T09:33:28.002Z",
"dateReserved": "2022-10-26T07:17:06.425Z",
"dateUpdated": "2025-03-25T13:54:18.752Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-22289 (GCVE-0-2021-22289)
Vulnerability from cvelistv5 – Published: 2022-08-11 14:56 – Updated: 2024-08-03 18:37
VLAI?
Summary
Improper Input Validation vulnerability in the project upload mechanism in B&R Automation Studio version >=4.0 may allow an unauthenticated network attacker to execute code.
Severity ?
8.3 (High)
CWE
- CWE-20 - Improper Input Validation
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| B&R Industrial Automation | Automation Studio |
Affected:
4 , < unspecified
(custom)
|
Credits
Mr. Mashav Sapir of Claroty
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T18:37:18.480Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.br-automation.com/downloads_br_productcatalogue/assets/1640529306294-en-original-1.0.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Automation Studio",
"vendor": "B\u0026R Industrial Automation",
"versions": [
{
"lessThan": "unspecified",
"status": "affected",
"version": "4",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Mr. Mashav Sapir of Claroty"
}
],
"descriptions": [
{
"lang": "en",
"value": "Improper Input Validation vulnerability in the project upload mechanism in B\u0026R Automation Studio version \u003e=4.0 may allow an unauthenticated network attacker to execute code."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.3,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:C/C:H/I:H/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-20",
"description": "CWE-20 Improper Input Validation",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-08-11T14:56:01",
"orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
"shortName": "ABB"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.br-automation.com/downloads_br_productcatalogue/assets/1640529306294-en-original-1.0.pdf"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "RCE through Project Upload from Target",
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@ch.abb.com",
"ID": "CVE-2021-22289",
"STATE": "PUBLIC",
"TITLE": "RCE through Project Upload from Target"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Automation Studio",
"version": {
"version_data": [
{
"version_affected": "\u003e=",
"version_value": "4"
}
]
}
}
]
},
"vendor_name": "B\u0026R Industrial Automation"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "Mr. Mashav Sapir of Claroty"
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Improper Input Validation vulnerability in the project upload mechanism in B\u0026R Automation Studio version \u003e=4.0 may allow an unauthenticated network attacker to execute code."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.3,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:C/C:H/I:H/A:H",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-20 Improper Input Validation"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.br-automation.com/downloads_br_productcatalogue/assets/1640529306294-en-original-1.0.pdf",
"refsource": "MISC",
"url": "https://www.br-automation.com/downloads_br_productcatalogue/assets/1640529306294-en-original-1.0.pdf"
}
]
},
"source": {
"discovery": "UNKNOWN"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
"assignerShortName": "ABB",
"cveId": "CVE-2021-22289",
"datePublished": "2022-08-11T14:56:02",
"dateReserved": "2021-01-05T00:00:00",
"dateUpdated": "2024-08-03T18:37:18.480Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-22275 (GCVE-0-2021-22275)
Vulnerability from cvelistv5 – Published: 2022-05-13 14:23 – Updated: 2024-08-03 18:37
VLAI?
Summary
Buffer Overflow vulnerability in B&R Automation Runtime webserver allows an unauthenticated network-based attacker to stop the cyclic program on the device and cause a denial of service.
Severity ?
8.6 (High)
CWE
- CWE-120 - Buffer Overflow
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| B&R Automation | Automation Runtime webserver |
Affected:
unspecified , < 4.91
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T18:37:18.446Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.br-automation.com/downloads_br_productcatalogue/assets/1625405588264-en-original-1.0.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Automation Runtime webserver",
"vendor": "B\u0026R Automation",
"versions": [
{
"lessThan": "4.91",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Buffer Overflow vulnerability in B\u0026R Automation Runtime webserver allows an unauthenticated network-based attacker to stop the cyclic program on the device and cause a denial of service."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.6,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:N/I:N/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-120",
"description": "CWE-120 Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-05-13T14:23:20",
"orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
"shortName": "ABB"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.br-automation.com/downloads_br_productcatalogue/assets/1625405588264-en-original-1.0.pdf"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Denial of service vulnerability on Automation Runtime webserver",
"workarounds": [
{
"lang": "en",
"value": "B\u0026R recommends the following specific workarounds and mitigations:\nThe access to the Automation Runtime webserver should be restricted to legitimate network partners, using e.g. a sufficient Firewall setup and robust network segmentation. \nB\u0026R recommends deactivating Automation Runtime webserver when not needed."
}
],
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@ch.abb.com",
"ID": "CVE-2021-22275",
"STATE": "PUBLIC",
"TITLE": "Denial of service vulnerability on Automation Runtime webserver"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Automation Runtime webserver",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_value": "4.91"
}
]
}
}
]
},
"vendor_name": "B\u0026R Automation"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Buffer Overflow vulnerability in B\u0026R Automation Runtime webserver allows an unauthenticated network-based attacker to stop the cyclic program on the device and cause a denial of service."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.6,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:N/I:N/A:H",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-120 Buffer Overflow"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.br-automation.com/downloads_br_productcatalogue/assets/1625405588264-en-original-1.0.pdf",
"refsource": "MISC",
"url": "https://www.br-automation.com/downloads_br_productcatalogue/assets/1625405588264-en-original-1.0.pdf"
}
]
},
"source": {
"discovery": "UNKNOWN"
},
"work_around": [
{
"lang": "en",
"value": "B\u0026R recommends the following specific workarounds and mitigations:\nThe access to the Automation Runtime webserver should be restricted to legitimate network partners, using e.g. a sufficient Firewall setup and robust network segmentation. \nB\u0026R recommends deactivating Automation Runtime webserver when not needed."
}
]
}
}
},
"cveMetadata": {
"assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
"assignerShortName": "ABB",
"cveId": "CVE-2021-22275",
"datePublished": "2022-05-13T14:23:20",
"dateReserved": "2021-01-05T00:00:00",
"dateUpdated": "2024-08-03T18:37:18.446Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-19878 (GCVE-0-2019-19878)
Vulnerability from cvelistv5 – Published: 2020-11-27 16:24 – Updated: 2024-08-05 02:32
VLAI?
Summary
An issue was discovered in B&R Industrial Automation APROL before R4.2 V7.08. An attacker can get access to historical data from AprolSqlServer by bypassing authentication, a different vulnerability than CVE-2019-16358.
Severity ?
No CVSS data available.
CWE
- n/a
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T02:32:09.328Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.br-automation.com/downloads_br_productcatalogue/BRP44400000000000000585952/APROL_R42_A1_ReleaseNotes_001.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An issue was discovered in B\u0026R Industrial Automation APROL before R4.2 V7.08. An attacker can get access to historical data from AprolSqlServer by bypassing authentication, a different vulnerability than CVE-2019-16358."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-11-27T16:24:00",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.br-automation.com/downloads_br_productcatalogue/BRP44400000000000000585952/APROL_R42_A1_ReleaseNotes_001.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2019-19878",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "An issue was discovered in B\u0026R Industrial Automation APROL before R4.2 V7.08. An attacker can get access to historical data from AprolSqlServer by bypassing authentication, a different vulnerability than CVE-2019-16358."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.br-automation.com/downloads_br_productcatalogue/BRP44400000000000000585952/APROL_R42_A1_ReleaseNotes_001.pdf",
"refsource": "MISC",
"url": "https://www.br-automation.com/downloads_br_productcatalogue/BRP44400000000000000585952/APROL_R42_A1_ReleaseNotes_001.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2019-19878",
"datePublished": "2020-11-27T16:24:00",
"dateReserved": "2019-12-17T00:00:00",
"dateUpdated": "2024-08-05T02:32:09.328Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-19877 (GCVE-0-2019-19877)
Vulnerability from cvelistv5 – Published: 2020-11-27 16:23 – Updated: 2024-08-05 02:32
VLAI?
Summary
An issue was discovered in B&R Industrial Automation APROL before R4.2 V7.08. An attacker can get access to sensitive information outside the working directory via Directory Traversal attacks against AprolSqlServer, a different vulnerability than CVE-2019-16357.
Severity ?
No CVSS data available.
CWE
- n/a
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T02:32:09.381Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.br-automation.com/downloads_br_productcatalogue/BRP44400000000000000585952/APROL_R42_A1_ReleaseNotes_001.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An issue was discovered in B\u0026R Industrial Automation APROL before R4.2 V7.08. An attacker can get access to sensitive information outside the working directory via Directory Traversal attacks against AprolSqlServer, a different vulnerability than CVE-2019-16357."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-11-27T16:23:21",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.br-automation.com/downloads_br_productcatalogue/BRP44400000000000000585952/APROL_R42_A1_ReleaseNotes_001.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2019-19877",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "An issue was discovered in B\u0026R Industrial Automation APROL before R4.2 V7.08. An attacker can get access to sensitive information outside the working directory via Directory Traversal attacks against AprolSqlServer, a different vulnerability than CVE-2019-16357."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.br-automation.com/downloads_br_productcatalogue/BRP44400000000000000585952/APROL_R42_A1_ReleaseNotes_001.pdf",
"refsource": "MISC",
"url": "https://www.br-automation.com/downloads_br_productcatalogue/BRP44400000000000000585952/APROL_R42_A1_ReleaseNotes_001.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2019-19877",
"datePublished": "2020-11-27T16:23:21",
"dateReserved": "2019-12-17T00:00:00",
"dateUpdated": "2024-08-05T02:32:09.381Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-19876 (GCVE-0-2019-19876)
Vulnerability from cvelistv5 – Published: 2020-11-27 16:22 – Updated: 2024-08-05 02:32
VLAI?
Summary
An issue was discovered in B&R Industrial Automation APROL before R4.2 V7.08. An EnMon PHP script was vulnerable to SQL injection, a different vulnerability than CVE-2019-10006.
Severity ?
No CVSS data available.
CWE
- n/a
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T02:32:09.337Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.br-automation.com/downloads_br_productcatalogue/BRP44400000000000000585952/APROL_R42_A1_ReleaseNotes_001.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An issue was discovered in B\u0026R Industrial Automation APROL before R4.2 V7.08. An EnMon PHP script was vulnerable to SQL injection, a different vulnerability than CVE-2019-10006."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-11-27T16:22:13",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.br-automation.com/downloads_br_productcatalogue/BRP44400000000000000585952/APROL_R42_A1_ReleaseNotes_001.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2019-19876",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "An issue was discovered in B\u0026R Industrial Automation APROL before R4.2 V7.08. An EnMon PHP script was vulnerable to SQL injection, a different vulnerability than CVE-2019-10006."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.br-automation.com/downloads_br_productcatalogue/BRP44400000000000000585952/APROL_R42_A1_ReleaseNotes_001.pdf",
"refsource": "MISC",
"url": "https://www.br-automation.com/downloads_br_productcatalogue/BRP44400000000000000585952/APROL_R42_A1_ReleaseNotes_001.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2019-19876",
"datePublished": "2020-11-27T16:22:13",
"dateReserved": "2019-12-17T00:00:00",
"dateUpdated": "2024-08-05T02:32:09.337Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-19875 (GCVE-0-2019-19875)
Vulnerability from cvelistv5 – Published: 2020-11-27 16:21 – Updated: 2024-08-05 02:32
VLAI?
Summary
An issue was discovered in B&R Industrial Automation APROL before R4.2 V7.08. Arbitrary commands could be injected (using Python scripts) via the AprolCluster script that is invoked via sudo and thus executes with root privileges, a different vulnerability than CVE-2019-16364.
Severity ?
No CVSS data available.
CWE
- n/a
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T02:32:09.359Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.br-automation.com/downloads_br_productcatalogue/BRP44400000000000000585952/APROL_R42_A1_ReleaseNotes_001.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An issue was discovered in B\u0026R Industrial Automation APROL before R4.2 V7.08. Arbitrary commands could be injected (using Python scripts) via the AprolCluster script that is invoked via sudo and thus executes with root privileges, a different vulnerability than CVE-2019-16364."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-11-27T16:21:13",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.br-automation.com/downloads_br_productcatalogue/BRP44400000000000000585952/APROL_R42_A1_ReleaseNotes_001.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2019-19875",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "An issue was discovered in B\u0026R Industrial Automation APROL before R4.2 V7.08. Arbitrary commands could be injected (using Python scripts) via the AprolCluster script that is invoked via sudo and thus executes with root privileges, a different vulnerability than CVE-2019-16364."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.br-automation.com/downloads_br_productcatalogue/BRP44400000000000000585952/APROL_R42_A1_ReleaseNotes_001.pdf",
"refsource": "MISC",
"url": "https://www.br-automation.com/downloads_br_productcatalogue/BRP44400000000000000585952/APROL_R42_A1_ReleaseNotes_001.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2019-19875",
"datePublished": "2020-11-27T16:21:13",
"dateReserved": "2019-12-17T00:00:00",
"dateUpdated": "2024-08-05T02:32:09.359Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-19874 (GCVE-0-2019-19874)
Vulnerability from cvelistv5 – Published: 2020-11-27 16:20 – Updated: 2024-08-05 02:32
VLAI?
Summary
An issue was discovered in B&R Industrial Automation APROL before R4.2 V7.08. Some web scripts in the web interface allowed injection and execution of arbitrary unintended commands on the web server, a different vulnerability than CVE-2019-16364.
Severity ?
No CVSS data available.
CWE
- n/a
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T02:32:08.891Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.br-automation.com/downloads_br_productcatalogue/BRP44400000000000000585952/APROL_R42_A1_ReleaseNotes_001.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An issue was discovered in B\u0026R Industrial Automation APROL before R4.2 V7.08. Some web scripts in the web interface allowed injection and execution of arbitrary unintended commands on the web server, a different vulnerability than CVE-2019-16364."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-11-27T16:20:06",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.br-automation.com/downloads_br_productcatalogue/BRP44400000000000000585952/APROL_R42_A1_ReleaseNotes_001.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2019-19874",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "An issue was discovered in B\u0026R Industrial Automation APROL before R4.2 V7.08. Some web scripts in the web interface allowed injection and execution of arbitrary unintended commands on the web server, a different vulnerability than CVE-2019-16364."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.br-automation.com/downloads_br_productcatalogue/BRP44400000000000000585952/APROL_R42_A1_ReleaseNotes_001.pdf",
"refsource": "MISC",
"url": "https://www.br-automation.com/downloads_br_productcatalogue/BRP44400000000000000585952/APROL_R42_A1_ReleaseNotes_001.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2019-19874",
"datePublished": "2020-11-27T16:20:06",
"dateReserved": "2019-12-17T00:00:00",
"dateUpdated": "2024-08-05T02:32:08.891Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-19873 (GCVE-0-2019-19873)
Vulnerability from cvelistv5 – Published: 2020-11-27 16:18 – Updated: 2024-08-05 02:32
VLAI?
Summary
An issue was discovered in B&R Industrial Automation APROL before R4.2 V7.08. An attacker can get information from the AprolSqlServer DBMS by bypassing authentication, a different vulnerability than CVE-2019-16356 and CVE-2019-9983.
Severity ?
No CVSS data available.
CWE
- n/a
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T02:32:08.812Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.br-automation.com/downloads_br_productcatalogue/BRP44400000000000000585952/APROL_R42_A1_ReleaseNotes_001.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An issue was discovered in B\u0026R Industrial Automation APROL before R4.2 V7.08. An attacker can get information from the AprolSqlServer DBMS by bypassing authentication, a different vulnerability than CVE-2019-16356 and CVE-2019-9983."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-11-27T16:18:34",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.br-automation.com/downloads_br_productcatalogue/BRP44400000000000000585952/APROL_R42_A1_ReleaseNotes_001.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2019-19873",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "An issue was discovered in B\u0026R Industrial Automation APROL before R4.2 V7.08. An attacker can get information from the AprolSqlServer DBMS by bypassing authentication, a different vulnerability than CVE-2019-16356 and CVE-2019-9983."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.br-automation.com/downloads_br_productcatalogue/BRP44400000000000000585952/APROL_R42_A1_ReleaseNotes_001.pdf",
"refsource": "MISC",
"url": "https://www.br-automation.com/downloads_br_productcatalogue/BRP44400000000000000585952/APROL_R42_A1_ReleaseNotes_001.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2019-19873",
"datePublished": "2020-11-27T16:18:34",
"dateReserved": "2019-12-17T00:00:00",
"dateUpdated": "2024-08-05T02:32:08.812Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-19872 (GCVE-0-2019-19872)
Vulnerability from cvelistv5 – Published: 2020-11-27 14:08 – Updated: 2024-08-05 02:32
VLAI?
Summary
An issue was discovered in B&R Industrial Automation APROL before R4.2 V7.08. The AprolLoader could be used to inject and execute arbitrary unintended commands via an unspecified attack scenario, a different vulnerability than CVE-2019-16364.
Severity ?
No CVSS data available.
CWE
- n/a
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T02:32:08.921Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.br-automation.com/downloads_br_productcatalogue/BRP44400000000000000585952/APROL_R42_A1_ReleaseNotes_001.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An issue was discovered in B\u0026R Industrial Automation APROL before R4.2 V7.08. The AprolLoader could be used to inject and execute arbitrary unintended commands via an unspecified attack scenario, a different vulnerability than CVE-2019-16364."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-11-27T14:08:11",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.br-automation.com/downloads_br_productcatalogue/BRP44400000000000000585952/APROL_R42_A1_ReleaseNotes_001.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2019-19872",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "An issue was discovered in B\u0026R Industrial Automation APROL before R4.2 V7.08. The AprolLoader could be used to inject and execute arbitrary unintended commands via an unspecified attack scenario, a different vulnerability than CVE-2019-16364."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.br-automation.com/downloads_br_productcatalogue/BRP44400000000000000585952/APROL_R42_A1_ReleaseNotes_001.pdf",
"refsource": "MISC",
"url": "https://www.br-automation.com/downloads_br_productcatalogue/BRP44400000000000000585952/APROL_R42_A1_ReleaseNotes_001.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2019-19872",
"datePublished": "2020-11-27T14:08:11",
"dateReserved": "2019-12-17T00:00:00",
"dateUpdated": "2024-08-05T02:32:08.921Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-19869 (GCVE-0-2019-19869)
Vulnerability from cvelistv5 – Published: 2020-11-27 14:06 – Updated: 2024-08-05 02:32
VLAI?
Summary
An issue was discovered in B&R Industrial Automation APROL before R4.2 V7.08. PVs could be changed (unencrypted) by using the IosHttp service and the JSON interface.
Severity ?
No CVSS data available.
CWE
- n/a
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T02:32:08.916Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.br-automation.com/downloads_br_productcatalogue/BRP44400000000000000585952/APROL_R42_A1_ReleaseNotes_001.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An issue was discovered in B\u0026R Industrial Automation APROL before R4.2 V7.08. PVs could be changed (unencrypted) by using the IosHttp service and the JSON interface."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-11-27T14:06:07",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.br-automation.com/downloads_br_productcatalogue/BRP44400000000000000585952/APROL_R42_A1_ReleaseNotes_001.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2019-19869",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "An issue was discovered in B\u0026R Industrial Automation APROL before R4.2 V7.08. PVs could be changed (unencrypted) by using the IosHttp service and the JSON interface."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.br-automation.com/downloads_br_productcatalogue/BRP44400000000000000585952/APROL_R42_A1_ReleaseNotes_001.pdf",
"refsource": "MISC",
"url": "https://www.br-automation.com/downloads_br_productcatalogue/BRP44400000000000000585952/APROL_R42_A1_ReleaseNotes_001.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2019-19869",
"datePublished": "2020-11-27T14:06:07",
"dateReserved": "2019-12-17T00:00:00",
"dateUpdated": "2024-08-05T02:32:08.916Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-11637 (GCVE-0-2020-11637)
Vulnerability from cvelistv5 – Published: 2020-10-15 15:08 – Updated: 2024-09-16 16:33
VLAI?
Summary
A memory leak in the TFTP service in B&R Automation Runtime versions <N4.26, <N4.34, <F4.45, <E4.53, <D4.63, <A4.73 and prior could allow an unauthenticated attacker with network access to cause a denial of service (DoS) condition.
Severity ?
5.8 (Medium)
CWE
- CWE-401 - Improper Release of Memory Before Removing Last Reference
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| B&R | Automation Runtime |
Affected:
unspecified , ≤ 4.1x
(custom)
Affected: 4.2x , < N4.26 (custom) Affected: 4.3x , < N4.34 (custom) Affected: 4.4x , < F4.45 (custom) Affected: 4.5x , < E4.53 (custom) Affected: 4.6x , < D4.63 (custom) Affected: 4.7x , < A4.73 (custom) |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T11:35:13.385Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.br-automation.com/downloads_br_productcatalogue/assets/1595163815396-de-original-1.0.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Automation Runtime",
"vendor": "B\u0026R",
"versions": [
{
"lessThanOrEqual": "4.1x",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
},
{
"lessThan": "N4.26",
"status": "affected",
"version": "4.2x",
"versionType": "custom"
},
{
"lessThan": "N4.34",
"status": "affected",
"version": "4.3x",
"versionType": "custom"
},
{
"lessThan": "F4.45",
"status": "affected",
"version": "4.4x",
"versionType": "custom"
},
{
"lessThan": "E4.53",
"status": "affected",
"version": "4.5x",
"versionType": "custom"
},
{
"lessThan": "D4.63",
"status": "affected",
"version": "4.6x",
"versionType": "custom"
},
{
"lessThan": "A4.73",
"status": "affected",
"version": "4.7x",
"versionType": "custom"
}
]
}
],
"datePublic": "2020-08-12T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "A memory leak in the TFTP service in B\u0026R Automation Runtime versions \u003cN4.26, \u003cN4.34, \u003cF4.45, \u003cE4.53, \u003cD4.63, \u003cA4.73 and prior could allow an unauthenticated attacker with network access to cause a denial of service (DoS) condition."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 5.8,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:N/I:N/A:L",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-401",
"description": "CWE-401 Improper Release of Memory Before Removing Last Reference",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-10-15T15:08:14",
"orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
"shortName": "ABB"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.br-automation.com/downloads_br_productcatalogue/assets/1595163815396-de-original-1.0.pdf"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Automation Runtime TFTP Service DoS Vulnerability",
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@ch.abb.com",
"DATE_PUBLIC": "2020-08-12T00:00:00.000Z",
"ID": "CVE-2020-11637",
"STATE": "PUBLIC",
"TITLE": "Automation Runtime TFTP Service DoS Vulnerability"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Automation Runtime",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_value": "4.1x"
},
{
"version_affected": "\u003c",
"version_name": "4.2x",
"version_value": "N4.26"
},
{
"version_affected": "\u003c",
"version_name": "4.3x",
"version_value": "N4.34"
},
{
"version_affected": "\u003c",
"version_name": "4.4x",
"version_value": "F4.45"
},
{
"version_affected": "\u003c",
"version_name": "4.5x",
"version_value": "E4.53"
},
{
"version_affected": "\u003c",
"version_name": "4.6x",
"version_value": "D4.63"
},
{
"version_affected": "\u003c",
"version_name": "4.7x",
"version_value": "A4.73"
}
]
}
}
]
},
"vendor_name": "B\u0026R"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A memory leak in the TFTP service in B\u0026R Automation Runtime versions \u003cN4.26, \u003cN4.34, \u003cF4.45, \u003cE4.53, \u003cD4.63, \u003cA4.73 and prior could allow an unauthenticated attacker with network access to cause a denial of service (DoS) condition."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 5.8,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:N/I:N/A:L",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-401 Improper Release of Memory Before Removing Last Reference"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.br-automation.com/downloads_br_productcatalogue/assets/1595163815396-de-original-1.0.pdf",
"refsource": "MISC",
"url": "https://www.br-automation.com/downloads_br_productcatalogue/assets/1595163815396-de-original-1.0.pdf"
}
]
},
"source": {
"discovery": "UNKNOWN"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
"assignerShortName": "ABB",
"cveId": "CVE-2020-11637",
"datePublished": "2020-10-15T15:08:14.438915Z",
"dateReserved": "2020-04-08T00:00:00",
"dateUpdated": "2024-09-16T16:33:01.394Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-11642 (GCVE-0-2020-11642)
Vulnerability from cvelistv5 – Published: 2020-10-15 14:58 – Updated: 2024-09-17 01:11
VLAI?
Summary
The local file inclusion vulnerability present in B&R SiteManager versions <9.2.620236042 allows authenticated users to impact availability of SiteManager instances.
Severity ?
7.7 (High)
CWE
- CWE-552 - Files or Directories Accessible to External Parties
Assigner
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| B&R | SiteManager |
Affected:
unspecified , < 9.2.620236042
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T11:35:13.388Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.br-automation.com/downloads_br_productcatalogue/assets/1600003183751-de-original-1.0.pdf"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-273-03"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "SiteManager",
"vendor": "B\u0026R",
"versions": [
{
"lessThan": "9.2.620236042",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
}
],
"datePublic": "2020-09-29T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "The local file inclusion vulnerability present in B\u0026R SiteManager versions \u003c9.2.620236042 allows authenticated users to impact availability of SiteManager instances."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.7,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:N/I:N/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-552",
"description": "CWE-552 Files or Directories Accessible to External Parties",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-11-17T01:33:36",
"orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
"shortName": "ABB"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.br-automation.com/downloads_br_productcatalogue/assets/1600003183751-de-original-1.0.pdf"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-273-03"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "SiteManager Denial of Service via Local File Inclusion Vulnerability",
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@ch.abb.com",
"DATE_PUBLIC": "2020-09-29T00:00:00.000Z",
"ID": "CVE-2020-11642",
"STATE": "PUBLIC",
"TITLE": "SiteManager Denial of Service via Local File Inclusion Vulnerability"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "SiteManager",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_value": "9.2.620236042"
}
]
}
}
]
},
"vendor_name": "B\u0026R"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "The local file inclusion vulnerability present in B\u0026R SiteManager versions \u003c9.2.620236042 allows authenticated users to impact availability of SiteManager instances."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.7,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:N/I:N/A:H",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-552 Files or Directories Accessible to External Parties"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.br-automation.com/downloads_br_productcatalogue/assets/1600003183751-de-original-1.0.pdf",
"refsource": "MISC",
"url": "https://www.br-automation.com/downloads_br_productcatalogue/assets/1600003183751-de-original-1.0.pdf"
},
{
"name": "https://us-cert.cisa.gov/ics/advisories/icsa-20-273-03",
"refsource": "MISC",
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-273-03"
}
]
},
"source": {
"discovery": "UNKNOWN"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
"assignerShortName": "ABB",
"cveId": "CVE-2020-11642",
"datePublished": "2020-10-15T14:58:48.634942Z",
"dateReserved": "2020-04-08T00:00:00",
"dateUpdated": "2024-09-17T01:11:16.044Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}