CVE-2019-12702
Vulnerability from cvelistv5
Published
2019-10-16 18:36
Modified
2024-11-21 19:09
Summary
A vulnerability in the web-based management interface of Cisco SPA100 Series Analog Telephone Adapters (ATAs) could allow an authenticated, remote attacker to conduct cross-site scripting attacks. The vulnerability is due to insufficient validation of user-supplied input by the web-based management interface of the affected software. An attacker could exploit this vulnerability by persuading a user to click a crafted link. A successful exploit could allow the attacker to execute arbitrary script code in the context of the affected interface or access sensitive, browser-based information.
Impacted products
Vendor Product Version
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T23:24:39.184Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "20191016 Cisco SPA100 Series Analog Telephone Adapters Reflected Cross-Site Scripting Vulnerability",
            "tags": [
              "vendor-advisory",
              "x_refsource_CISCO",
              "x_transferred"
            ],
            "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20191016-spa-reflected-xss"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2019-12702",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-11-21T18:56:21.823778Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-11-21T19:09:18.056Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Cisco SPA112 2-Port Phone Adapter",
          "vendor": "Cisco",
          "versions": [
            {
              "lessThan": "n/a",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        }
      ],
      "datePublic": "2019-10-16T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability in the web-based management interface of Cisco SPA100 Series Analog Telephone Adapters (ATAs) could allow an authenticated, remote attacker to conduct cross-site scripting attacks. The vulnerability is due to insufficient validation of user-supplied input by the web-based management interface of the affected software. An attacker could exploit this vulnerability by persuading a user to click a crafted link. A successful exploit could allow the attacker to execute arbitrary script code in the context of the affected interface or access sensitive, browser-based information."
        }
      ],
      "exploits": [
        {
          "lang": "en",
          "value": "The Cisco Product Security Incident Response Team (PSIRT) is not aware of any public announcements or malicious use of the vulnerability that is described in this advisory."
        }
      ],
      "metrics": [
        {
          "cvssV3_0": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 5.4,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "LOW",
            "privilegesRequired": "LOW",
            "scope": "CHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N",
            "version": "3.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-79",
              "description": "CWE-79",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2019-10-16T18:36:28",
        "orgId": "d1c1063e-7a18-46af-9102-31f8928bc633",
        "shortName": "cisco"
      },
      "references": [
        {
          "name": "20191016 Cisco SPA100 Series Analog Telephone Adapters Reflected Cross-Site Scripting Vulnerability",
          "tags": [
            "vendor-advisory",
            "x_refsource_CISCO"
          ],
          "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20191016-spa-reflected-xss"
        }
      ],
      "source": {
        "advisory": "cisco-sa-20191016-spa-reflected-xss",
        "defect": [
          [
            "CSCvq50512"
          ]
        ],
        "discovery": "INTERNAL"
      },
      "title": "Cisco SPA100 Series Analog Telephone Adapters Reflected Cross-Site Scripting Vulnerability",
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "psirt@cisco.com",
          "DATE_PUBLIC": "2019-10-16T16:00:00-0700",
          "ID": "CVE-2019-12702",
          "STATE": "PUBLIC",
          "TITLE": "Cisco SPA100 Series Analog Telephone Adapters Reflected Cross-Site Scripting Vulnerability"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Cisco SPA112 2-Port Phone Adapter",
                      "version": {
                        "version_data": [
                          {
                            "affected": "\u003c",
                            "version_affected": "\u003c",
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Cisco"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability in the web-based management interface of Cisco SPA100 Series Analog Telephone Adapters (ATAs) could allow an authenticated, remote attacker to conduct cross-site scripting attacks. The vulnerability is due to insufficient validation of user-supplied input by the web-based management interface of the affected software. An attacker could exploit this vulnerability by persuading a user to click a crafted link. A successful exploit could allow the attacker to execute arbitrary script code in the context of the affected interface or access sensitive, browser-based information."
            }
          ]
        },
        "exploit": [
          {
            "lang": "en",
            "value": "The Cisco Product Security Incident Response Team (PSIRT) is not aware of any public announcements or malicious use of the vulnerability that is described in this advisory."
          }
        ],
        "impact": {
          "cvss": {
            "baseScore": "5.4",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N",
            "version": "3.0"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-79"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "20191016 Cisco SPA100 Series Analog Telephone Adapters Reflected Cross-Site Scripting Vulnerability",
              "refsource": "CISCO",
              "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20191016-spa-reflected-xss"
            }
          ]
        },
        "source": {
          "advisory": "cisco-sa-20191016-spa-reflected-xss",
          "defect": [
            [
              "CSCvq50512"
            ]
          ],
          "discovery": "INTERNAL"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "d1c1063e-7a18-46af-9102-31f8928bc633",
    "assignerShortName": "cisco",
    "cveId": "CVE-2019-12702",
    "datePublished": "2019-10-16T18:36:28.128319Z",
    "dateReserved": "2019-06-04T00:00:00",
    "dateUpdated": "2024-11-21T19:09:18.056Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "fkie_nvd": {
      "configurations": "[{\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:cisco:spa112_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"1.4.1\", \"matchCriteriaId\": \"CDE978DB-5C48-4E25-A67E-497F033366E1\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:cisco:spa112_firmware:1.4.1:-:*:*:*:*:*:*\", \"matchCriteriaId\": \"CDBCF90E-2E7B-4A58-B0DF-4A02D880EF0D\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:cisco:spa112_firmware:1.4.1:sr1:*:*:*:*:*:*\", \"matchCriteriaId\": \"661CECD1-038C-41B1-AEB7-9C3E5087E088\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:cisco:spa112_firmware:1.4.1:sr2:*:*:*:*:*:*\", \"matchCriteriaId\": \"691B5688-DDAF-49EE-8E9F-ABB06BB628B0\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:cisco:spa112_firmware:1.4.1:sr3:*:*:*:*:*:*\", \"matchCriteriaId\": \"C4BAC9C2-3475-42EC-81FA-12BE338C936A\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:cisco:spa112:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"F61B8649-0781-4AF5-8CED-34616A9524FF\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:cisco:spa122_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"1.4.1\", \"matchCriteriaId\": \"22E490C8-BA3D-44E0-A677-C3311489EED5\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:cisco:spa122_firmware:1.4.1:-:*:*:*:*:*:*\", \"matchCriteriaId\": \"30A5E568-2B2A-4A46-99E9-5FC203F96347\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:cisco:spa122_firmware:1.4.1:sr1:*:*:*:*:*:*\", \"matchCriteriaId\": \"4A1FCBBE-9EE3-4D9D-AD25-2D4FA5893263\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:cisco:spa122_firmware:1.4.1:sr2:*:*:*:*:*:*\", \"matchCriteriaId\": \"6D77D805-40B9-41F1-9A1A-C1A85E89361E\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:cisco:spa122_firmware:1.4.1:sr3:*:*:*:*:*:*\", \"matchCriteriaId\": \"1B7D0675-063B-45A2-985D-B32FF3D6E15B\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:cisco:spa122:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"8C874C71-46D9-48A4-81C9-7ADDDB22FC8C\"}]}]}]",
      "descriptions": "[{\"lang\": \"en\", \"value\": \"A vulnerability in the web-based management interface of Cisco SPA100 Series Analog Telephone Adapters (ATAs) could allow an authenticated, remote attacker to conduct cross-site scripting attacks. The vulnerability is due to insufficient validation of user-supplied input by the web-based management interface of the affected software. An attacker could exploit this vulnerability by persuading a user to click a crafted link. A successful exploit could allow the attacker to execute arbitrary script code in the context of the affected interface or access sensitive, browser-based information.\"}, {\"lang\": \"es\", \"value\": \"Una vulnerabilidad en la interfaz de administraci\\u00f3n basada en web de los dispositivos Cisco SPA100 Series Analog Telephone Adapters (ATAs), podr\\u00eda permitir a un atacante remoto autenticado conducir ataques de tipo cross-site scripting. La vulnerabilidad es debido a una comprobaci\\u00f3n insuficiente de la entrada suministrada por el usuario mediante la interfaz de administraci\\u00f3n basada en web del software afectado. Un atacante podr\\u00eda explotar esta vulnerabilidad persuadiendo a un usuario para que haga clic en un enlace dise\\u00f1ado. Una explotaci\\u00f3n con \\u00e9xito podr\\u00eda permitir al atacante ejecutar c\\u00f3digo de script arbitrario en el contexto de la interfaz afectada o acceder a informaci\\u00f3n confidencial basada en navegador.\"}]",
      "id": "CVE-2019-12702",
      "lastModified": "2024-11-21T04:23:23.773",
      "metrics": "{\"cvssMetricV31\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N\", \"baseScore\": 5.4, \"baseSeverity\": \"MEDIUM\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"LOW\", \"userInteraction\": \"REQUIRED\", \"scope\": \"CHANGED\", \"confidentialityImpact\": \"LOW\", \"integrityImpact\": \"LOW\", \"availabilityImpact\": \"NONE\"}, \"exploitabilityScore\": 2.3, \"impactScore\": 2.7}], \"cvssMetricV30\": [{\"source\": \"ykramarz@cisco.com\", \"type\": \"Secondary\", \"cvssData\": {\"version\": \"3.0\", \"vectorString\": \"CVSS:3.0/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N\", \"baseScore\": 5.4, \"baseSeverity\": \"MEDIUM\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"LOW\", \"userInteraction\": \"REQUIRED\", \"scope\": \"CHANGED\", \"confidentialityImpact\": \"LOW\", \"integrityImpact\": \"LOW\", \"availabilityImpact\": \"NONE\"}, \"exploitabilityScore\": 2.3, \"impactScore\": 2.7}], \"cvssMetricV2\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"2.0\", \"vectorString\": \"AV:N/AC:M/Au:S/C:N/I:P/A:N\", \"baseScore\": 3.5, \"accessVector\": \"NETWORK\", \"accessComplexity\": \"MEDIUM\", \"authentication\": \"SINGLE\", \"confidentialityImpact\": \"NONE\", \"integrityImpact\": \"PARTIAL\", \"availabilityImpact\": \"NONE\"}, \"baseSeverity\": \"LOW\", \"exploitabilityScore\": 6.8, \"impactScore\": 2.9, \"acInsufInfo\": false, \"obtainAllPrivilege\": false, \"obtainUserPrivilege\": false, \"obtainOtherPrivilege\": false, \"userInteractionRequired\": true}]}",
      "published": "2019-10-16T19:15:11.427",
      "references": "[{\"url\": \"https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20191016-spa-reflected-xss\", \"source\": \"ykramarz@cisco.com\", \"tags\": [\"Vendor Advisory\"]}, {\"url\": \"https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20191016-spa-reflected-xss\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Vendor Advisory\"]}]",
      "sourceIdentifier": "ykramarz@cisco.com",
      "vulnStatus": "Modified",
      "weaknesses": "[{\"source\": \"ykramarz@cisco.com\", \"type\": \"Secondary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-79\"}]}, {\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-79\"}]}]"
    },
    "nvd": "{\"cve\":{\"id\":\"CVE-2019-12702\",\"sourceIdentifier\":\"ykramarz@cisco.com\",\"published\":\"2019-10-16T19:15:11.427\",\"lastModified\":\"2024-11-21T04:23:23.773\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability in the web-based management interface of Cisco SPA100 Series Analog Telephone Adapters (ATAs) could allow an authenticated, remote attacker to conduct cross-site scripting attacks. The vulnerability is due to insufficient validation of user-supplied input by the web-based management interface of the affected software. An attacker could exploit this vulnerability by persuading a user to click a crafted link. A successful exploit could allow the attacker to execute arbitrary script code in the context of the affected interface or access sensitive, browser-based information.\"},{\"lang\":\"es\",\"value\":\"Una vulnerabilidad en la interfaz de administraci\u00f3n basada en web de los dispositivos Cisco SPA100 Series Analog Telephone Adapters (ATAs), podr\u00eda permitir a un atacante remoto autenticado conducir ataques de tipo cross-site scripting. La vulnerabilidad es debido a una comprobaci\u00f3n insuficiente de la entrada suministrada por el usuario mediante la interfaz de administraci\u00f3n basada en web del software afectado. Un atacante podr\u00eda explotar esta vulnerabilidad persuadiendo a un usuario para que haga clic en un enlace dise\u00f1ado. Una explotaci\u00f3n con \u00e9xito podr\u00eda permitir al atacante ejecutar c\u00f3digo de script arbitrario en el contexto de la interfaz afectada o acceder a informaci\u00f3n confidencial basada en navegador.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N\",\"baseScore\":5.4,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"REQUIRED\",\"scope\":\"CHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"LOW\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":2.3,\"impactScore\":2.7}],\"cvssMetricV30\":[{\"source\":\"ykramarz@cisco.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.0\",\"vectorString\":\"CVSS:3.0/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N\",\"baseScore\":5.4,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"REQUIRED\",\"scope\":\"CHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"LOW\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":2.3,\"impactScore\":2.7}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:M/Au:S/C:N/I:P/A:N\",\"baseScore\":3.5,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"MEDIUM\",\"authentication\":\"SINGLE\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"NONE\"},\"baseSeverity\":\"LOW\",\"exploitabilityScore\":6.8,\"impactScore\":2.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":true}]},\"weaknesses\":[{\"source\":\"ykramarz@cisco.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-79\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-79\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:cisco:spa112_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"1.4.1\",\"matchCriteriaId\":\"CDE978DB-5C48-4E25-A67E-497F033366E1\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:cisco:spa112_firmware:1.4.1:-:*:*:*:*:*:*\",\"matchCriteriaId\":\"CDBCF90E-2E7B-4A58-B0DF-4A02D880EF0D\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:cisco:spa112_firmware:1.4.1:sr1:*:*:*:*:*:*\",\"matchCriteriaId\":\"661CECD1-038C-41B1-AEB7-9C3E5087E088\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:cisco:spa112_firmware:1.4.1:sr2:*:*:*:*:*:*\",\"matchCriteriaId\":\"691B5688-DDAF-49EE-8E9F-ABB06BB628B0\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:cisco:spa112_firmware:1.4.1:sr3:*:*:*:*:*:*\",\"matchCriteriaId\":\"C4BAC9C2-3475-42EC-81FA-12BE338C936A\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:cisco:spa112:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"F61B8649-0781-4AF5-8CED-34616A9524FF\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:cisco:spa122_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"1.4.1\",\"matchCriteriaId\":\"22E490C8-BA3D-44E0-A677-C3311489EED5\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:cisco:spa122_firmware:1.4.1:-:*:*:*:*:*:*\",\"matchCriteriaId\":\"30A5E568-2B2A-4A46-99E9-5FC203F96347\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:cisco:spa122_firmware:1.4.1:sr1:*:*:*:*:*:*\",\"matchCriteriaId\":\"4A1FCBBE-9EE3-4D9D-AD25-2D4FA5893263\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:cisco:spa122_firmware:1.4.1:sr2:*:*:*:*:*:*\",\"matchCriteriaId\":\"6D77D805-40B9-41F1-9A1A-C1A85E89361E\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:cisco:spa122_firmware:1.4.1:sr3:*:*:*:*:*:*\",\"matchCriteriaId\":\"1B7D0675-063B-45A2-985D-B32FF3D6E15B\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:cisco:spa122:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"8C874C71-46D9-48A4-81C9-7ADDDB22FC8C\"}]}]}],\"references\":[{\"url\":\"https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20191016-spa-reflected-xss\",\"source\":\"ykramarz@cisco.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20191016-spa-reflected-xss\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]}]}}",
    "vulnrichment": {
      "containers": "{\"adp\": [{\"title\": \"CVE Program Container\", \"references\": [{\"url\": \"https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20191016-spa-reflected-xss\", \"name\": \"20191016 Cisco SPA100 Series Analog Telephone Adapters Reflected Cross-Site Scripting Vulnerability\", \"tags\": [\"vendor-advisory\", \"x_refsource_CISCO\", \"x_transferred\"]}], \"providerMetadata\": {\"orgId\": \"af854a3a-2127-422b-91ae-364da2661108\", \"shortName\": \"CVE\", \"dateUpdated\": \"2024-08-04T23:24:39.184Z\"}}, {\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2019-12702\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"partial\"}], \"version\": \"2.0.3\", \"timestamp\": \"2024-11-21T18:56:21.823778Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2024-11-21T18:57:40.472Z\"}}], \"cna\": {\"title\": \"Cisco SPA100 Series Analog Telephone Adapters Reflected Cross-Site Scripting Vulnerability\", \"source\": {\"defect\": [[\"CSCvq50512\"]], \"advisory\": \"cisco-sa-20191016-spa-reflected-xss\", \"discovery\": \"INTERNAL\"}, \"metrics\": [{\"cvssV3_0\": {\"scope\": \"CHANGED\", \"version\": \"3.0\", \"baseScore\": 5.4, \"attackVector\": \"NETWORK\", \"baseSeverity\": \"MEDIUM\", \"vectorString\": \"CVSS:3.0/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N\", \"integrityImpact\": \"LOW\", \"userInteraction\": \"REQUIRED\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"NONE\", \"privilegesRequired\": \"LOW\", \"confidentialityImpact\": \"LOW\"}}], \"affected\": [{\"vendor\": \"Cisco\", \"product\": \"Cisco SPA112 2-Port Phone Adapter\", \"versions\": [{\"status\": \"affected\", \"version\": \"unspecified\", \"lessThan\": \"n/a\", \"versionType\": \"custom\"}]}], \"exploits\": [{\"lang\": \"en\", \"value\": \"The Cisco Product Security Incident Response Team (PSIRT) is not aware of any public announcements or malicious use of the vulnerability that is described in this advisory.\"}], \"datePublic\": \"2019-10-16T00:00:00\", \"references\": [{\"url\": \"https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20191016-spa-reflected-xss\", \"name\": \"20191016 Cisco SPA100 Series Analog Telephone Adapters Reflected Cross-Site Scripting Vulnerability\", \"tags\": [\"vendor-advisory\", \"x_refsource_CISCO\"]}], \"descriptions\": [{\"lang\": \"en\", \"value\": \"A vulnerability in the web-based management interface of Cisco SPA100 Series Analog Telephone Adapters (ATAs) could allow an authenticated, remote attacker to conduct cross-site scripting attacks. The vulnerability is due to insufficient validation of user-supplied input by the web-based management interface of the affected software. An attacker could exploit this vulnerability by persuading a user to click a crafted link. A successful exploit could allow the attacker to execute arbitrary script code in the context of the affected interface or access sensitive, browser-based information.\"}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-79\", \"description\": \"CWE-79\"}]}], \"providerMetadata\": {\"orgId\": \"d1c1063e-7a18-46af-9102-31f8928bc633\", \"shortName\": \"cisco\", \"dateUpdated\": \"2019-10-16T18:36:28\"}, \"x_legacyV4Record\": {\"impact\": {\"cvss\": {\"version\": \"3.0\", \"baseScore\": \"5.4\", \"vectorString\": \"CVSS:3.0/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N\"}}, \"source\": {\"defect\": [[\"CSCvq50512\"]], \"advisory\": \"cisco-sa-20191016-spa-reflected-xss\", \"discovery\": \"INTERNAL\"}, \"affects\": {\"vendor\": {\"vendor_data\": [{\"product\": {\"product_data\": [{\"version\": {\"version_data\": [{\"affected\": \"\u003c\", \"version_value\": \"n/a\", \"version_affected\": \"\u003c\"}]}, \"product_name\": \"Cisco SPA112 2-Port Phone Adapter\"}]}, \"vendor_name\": \"Cisco\"}]}}, \"exploit\": [{\"lang\": \"en\", \"value\": \"The Cisco Product Security Incident Response Team (PSIRT) is not aware of any public announcements or malicious use of the vulnerability that is described in this advisory.\"}], \"data_type\": \"CVE\", \"references\": {\"reference_data\": [{\"url\": \"https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20191016-spa-reflected-xss\", \"name\": \"20191016 Cisco SPA100 Series Analog Telephone Adapters Reflected Cross-Site Scripting Vulnerability\", \"refsource\": \"CISCO\"}]}, \"data_format\": \"MITRE\", \"description\": {\"description_data\": [{\"lang\": \"eng\", \"value\": \"A vulnerability in the web-based management interface of Cisco SPA100 Series Analog Telephone Adapters (ATAs) could allow an authenticated, remote attacker to conduct cross-site scripting attacks. The vulnerability is due to insufficient validation of user-supplied input by the web-based management interface of the affected software. An attacker could exploit this vulnerability by persuading a user to click a crafted link. A successful exploit could allow the attacker to execute arbitrary script code in the context of the affected interface or access sensitive, browser-based information.\"}]}, \"problemtype\": {\"problemtype_data\": [{\"description\": [{\"lang\": \"eng\", \"value\": \"CWE-79\"}]}]}, \"data_version\": \"4.0\", \"CVE_data_meta\": {\"ID\": \"CVE-2019-12702\", \"STATE\": \"PUBLIC\", \"TITLE\": \"Cisco SPA100 Series Analog Telephone Adapters Reflected Cross-Site Scripting Vulnerability\", \"ASSIGNER\": \"psirt@cisco.com\", \"DATE_PUBLIC\": \"2019-10-16T16:00:00-0700\"}}}}",
      "cveMetadata": "{\"cveId\": \"CVE-2019-12702\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2024-11-21T19:09:18.056Z\", \"dateReserved\": \"2019-06-04T00:00:00\", \"assignerOrgId\": \"d1c1063e-7a18-46af-9102-31f8928bc633\", \"datePublished\": \"2019-10-16T18:36:28.128319Z\", \"assignerShortName\": \"cisco\"}",
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.