CVE-2019-1895
Vulnerability from cvelistv5
Published
2019-08-07 20:55
Modified
2024-11-19 19:02
Severity ?
EPSS score ?
Summary
Cisco Enterprise NFV Infrastructure Software VNC Authentication Bypass Vulnerability
References
Impacted products
▼ | Vendor | Product |
---|---|---|
Cisco | Cisco Enterprise NFV Infrastructure Software |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T18:35:52.025Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "name": "20190807 Cisco Enterprise NFV Infrastructure Software VNC Authentication Bypass Vulnerability", "tags": [ "vendor-advisory", "x_refsource_CISCO", "x_transferred" ], "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20190807-nfvis-vnc-authbypass" } ], "title": "CVE Program Container" }, { "metrics": [ { "other": { "content": { "id": "CVE-2019-1895", "options": [ { "Exploitation": "none" }, { "Automatable": "yes" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-11-19T17:21:13.837538Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-11-19T19:02:07.688Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "Cisco Enterprise NFV Infrastructure Software", "vendor": "Cisco", "versions": [ { "lessThan": "3.12.1", "status": "affected", "version": "unspecified", "versionType": "custom" } ] } ], "datePublic": "2019-08-07T00:00:00", "descriptions": [ { "lang": "en", "value": "A vulnerability in the Virtual Network Computing (VNC) console implementation of Cisco Enterprise NFV Infrastructure Software (NFVIS) could allow an unauthenticated, remote attacker to access the VNC console session of an administrative user on an affected device. The vulnerability is due to an insufficient authentication mechanism used to establish a VNC session. An attacker could exploit this vulnerability by intercepting an administrator VNC session request prior to login. A successful exploit could allow the attacker to watch the administrator console session or interact with it, allowing admin access to the affected device." } ], "exploits": [ { "lang": "en", "value": "The Cisco Product Security Incident Response Team (PSIRT) is not aware of any public announcements or malicious use of the vulnerability that is described in this advisory." } ], "metrics": [ { "cvssV3_0": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-306", "description": "CWE-306", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2019-08-07T20:55:11", "orgId": "d1c1063e-7a18-46af-9102-31f8928bc633", "shortName": "cisco" }, "references": [ { "name": "20190807 Cisco Enterprise NFV Infrastructure Software VNC Authentication Bypass Vulnerability", "tags": [ "vendor-advisory", "x_refsource_CISCO" ], "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20190807-nfvis-vnc-authbypass" } ], "source": { "advisory": "cisco-sa-20190807-nfvis-vnc-authbypass", "defect": [ [ "CSCvm75496", "CSCvp00281" ] ], "discovery": "INTERNAL" }, "title": "Cisco Enterprise NFV Infrastructure Software VNC Authentication Bypass Vulnerability", "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "psirt@cisco.com", "DATE_PUBLIC": "2019-08-07T16:00:00-0700", "ID": "CVE-2019-1895", "STATE": "PUBLIC", "TITLE": "Cisco Enterprise NFV Infrastructure Software VNC Authentication Bypass Vulnerability" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "Cisco Enterprise NFV Infrastructure Software", "version": { "version_data": [ { "affected": "\u003c", "version_affected": "\u003c", "version_value": "3.12.1" } ] } } ] }, "vendor_name": "Cisco" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability in the Virtual Network Computing (VNC) console implementation of Cisco Enterprise NFV Infrastructure Software (NFVIS) could allow an unauthenticated, remote attacker to access the VNC console session of an administrative user on an affected device. The vulnerability is due to an insufficient authentication mechanism used to establish a VNC session. An attacker could exploit this vulnerability by intercepting an administrator VNC session request prior to login. A successful exploit could allow the attacker to watch the administrator console session or interact with it, allowing admin access to the affected device." } ] }, "exploit": [ { "lang": "en", "value": "The Cisco Product Security Incident Response Team (PSIRT) is not aware of any public announcements or malicious use of the vulnerability that is described in this advisory." } ], "impact": { "cvss": { "baseScore": "9.8", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-306" } ] } ] }, "references": { "reference_data": [ { "name": "20190807 Cisco Enterprise NFV Infrastructure Software VNC Authentication Bypass Vulnerability", "refsource": "CISCO", "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20190807-nfvis-vnc-authbypass" } ] }, "source": { "advisory": "cisco-sa-20190807-nfvis-vnc-authbypass", "defect": [ [ "CSCvm75496", "CSCvp00281" ] ], "discovery": "INTERNAL" } } } }, "cveMetadata": { "assignerOrgId": "d1c1063e-7a18-46af-9102-31f8928bc633", "assignerShortName": "cisco", "cveId": "CVE-2019-1895", "datePublished": "2019-08-07T20:55:11.724228Z", "dateReserved": "2018-12-06T00:00:00", "dateUpdated": "2024-11-19T19:02:07.688Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2019-1895\",\"sourceIdentifier\":\"ykramarz@cisco.com\",\"published\":\"2019-08-07T21:15:11.283\",\"lastModified\":\"2023-03-03T16:34:16.673\",\"vulnStatus\":\"Analyzed\",\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability in the Virtual Network Computing (VNC) console implementation of Cisco Enterprise NFV Infrastructure Software (NFVIS) could allow an unauthenticated, remote attacker to access the VNC console session of an administrative user on an affected device. The vulnerability is due to an insufficient authentication mechanism used to establish a VNC session. An attacker could exploit this vulnerability by intercepting an administrator VNC session request prior to login. A successful exploit could allow the attacker to watch the administrator console session or interact with it, allowing admin access to the affected device.\"},{\"lang\":\"es\",\"value\":\"Una vulnerabilidad en la implementaci\u00f3n de la consola de Virtual Network Computing (VNC) de Enterprise NFV Infrastructure Software (NFVIS) de Cisco, podr\u00eda permitir a un atacante remoto no autenticado acceder a la sesi\u00f3n de consola VNC de un usuario administrativo en un dispositivo afectado. La vulnerabilidad es debido a un mecanismo de autenticaci\u00f3n insuficiente utilizado para establecer una sesi\u00f3n VNC. Un atacante podr\u00eda explotar esta vulnerabilidad mediante la intercepci\u00f3n de una petici\u00f3n de sesi\u00f3n VNC de administrador antes de iniciar sesi\u00f3n. Una explotaci\u00f3n con \u00e9xito podr\u00eda permitir al atacante visualizar la sesi\u00f3n de la consola del administrador o interactuar con ella, permitiendo el acceso del administrador al dispositivo afectado.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\",\"baseScore\":9.8,\"baseSeverity\":\"CRITICAL\"},\"exploitabilityScore\":3.9,\"impactScore\":5.9}],\"cvssMetricV30\":[{\"source\":\"ykramarz@cisco.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.0\",\"vectorString\":\"CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\",\"baseScore\":9.8,\"baseSeverity\":\"CRITICAL\"},\"exploitabilityScore\":3.9,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:N/C:P/I:P/A:P\",\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"PARTIAL\",\"baseScore\":7.5},\"baseSeverity\":\"HIGH\",\"exploitabilityScore\":10.0,\"impactScore\":6.4,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-306\"}]},{\"source\":\"ykramarz@cisco.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-306\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:cisco:enterprise_network_function_virtualization_infrastructure:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"3.12.1\",\"matchCriteriaId\":\"F45F3AF9-2BE5-452D-AABD-259182A37789\"}]}]}],\"references\":[{\"url\":\"https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20190807-nfvis-vnc-authbypass\",\"source\":\"ykramarz@cisco.com\",\"tags\":[\"Vendor Advisory\"]}]}}" } }
Loading...
Loading...
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.