CVE-2020-5360
Vulnerability from cvelistv5
Published
2020-12-16 15:50
Modified
2024-09-16 22:57
Summary
Dell BSAFE Micro Edition Suite, versions prior to 4.5, are vulnerable to a Buffer Under-Read Vulnerability. An unauthenticated remote attacker could potentially exploit this vulnerability resulting in undefined behaviour, or a crash of the affected systems.
Impacted products
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T08:30:23.769Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.dell.com/support/kbdoc/en-us/000181098/dsa-2020-114-dell-bsafe-micro-edition-suite-multiple-security-vulnerabilities"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.oracle.com/security-alerts/cpuApr2021.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Dell BSAFE Micro Edition Suite",
          "vendor": "Dell",
          "versions": [
            {
              "lessThan": "4.5",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        }
      ],
      "datePublic": "2020-05-18T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "Dell BSAFE Micro Edition Suite, versions prior to 4.5, are vulnerable to a Buffer Under-Read Vulnerability. An unauthenticated remote attacker could potentially exploit this vulnerability resulting in undefined behaviour, or a crash of the affected systems."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "NONE",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-127",
              "description": "CWE-127: Buffer Under-read",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-06-14T17:20:23",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.dell.com/support/kbdoc/en-us/000181098/dsa-2020-114-dell-bsafe-micro-edition-suite-multiple-security-vulnerabilities"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.oracle.com/security-alerts/cpuApr2021.html"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "secure@dell.com",
          "DATE_PUBLIC": "2020-05-18",
          "ID": "CVE-2020-5360",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Dell BSAFE Micro Edition Suite",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_value": "4.5"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Dell"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Dell BSAFE Micro Edition Suite, versions prior to 4.5, are vulnerable to a Buffer Under-Read Vulnerability. An unauthenticated remote attacker could potentially exploit this vulnerability resulting in undefined behaviour, or a crash of the affected systems."
            }
          ]
        },
        "impact": {
          "cvss": {
            "baseScore": 7.5,
            "baseSeverity": "High",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-127: Buffer Under-read"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.dell.com/support/kbdoc/en-us/000181098/dsa-2020-114-dell-bsafe-micro-edition-suite-multiple-security-vulnerabilities",
              "refsource": "MISC",
              "url": "https://www.dell.com/support/kbdoc/en-us/000181098/dsa-2020-114-dell-bsafe-micro-edition-suite-multiple-security-vulnerabilities"
            },
            {
              "name": "https://www.oracle.com/security-alerts/cpuApr2021.html",
              "refsource": "MISC",
              "url": "https://www.oracle.com/security-alerts/cpuApr2021.html"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2020-5360",
    "datePublished": "2020-12-16T15:50:15.206975Z",
    "dateReserved": "2020-01-03T00:00:00",
    "dateUpdated": "2024-09-16T22:57:09.417Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2020-5360\",\"sourceIdentifier\":\"security_alert@emc.com\",\"published\":\"2020-12-16T16:15:14.477\",\"lastModified\":\"2021-12-09T18:21:28.650\",\"vulnStatus\":\"Analyzed\",\"descriptions\":[{\"lang\":\"en\",\"value\":\"Dell BSAFE Micro Edition Suite, versions prior to 4.5, are vulnerable to a Buffer Under-Read Vulnerability. An unauthenticated remote attacker could potentially exploit this vulnerability resulting in undefined behaviour, or a crash of the affected systems.\"},{\"lang\":\"es\",\"value\":\"Dell BSAFE Micro Edition Suite, versiones anteriores a 4.5, son susceptibles a una Vulnerabilidad de Lectura Insuficiente del B\u00fafer.\u0026#xa0;Un atacante remoto no autenticado podr\u00eda explotar esta vulnerabilidad resultando en un comportamiento indefinido o un bloqueo de los sistemas afectados\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"HIGH\",\"baseScore\":7.5,\"baseSeverity\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":3.6},{\"source\":\"security_alert@emc.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"HIGH\",\"baseScore\":7.5,\"baseSeverity\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":3.6}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:N/C:N/I:N/A:P\",\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"PARTIAL\",\"baseScore\":5.0},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":10.0,\"impactScore\":2.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-125\"}]},{\"source\":\"security_alert@emc.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-127\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:dell:bsafe_micro-edition-suite:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"4.5\",\"matchCriteriaId\":\"838D4372-D93F-4BAD-90C2-E6E3BB18C2A9\"}]}]},{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:oracle:database:12.1.0.2:*:*:*:enterprise:*:*:*\",\"matchCriteriaId\":\"89FE33CE-5995-4C53-8331-B49156F852B3\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:oracle:database:12.2.0.1:*:*:*:enterprise:*:*:*\",\"matchCriteriaId\":\"46E7237C-00BD-4490-96C3-A8EAE4CE2C0B\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:oracle:database:18c:*:*:*:enterprise:*:*:*\",\"matchCriteriaId\":\"20352616-6BCA-485D-8DD7-DFC97AD6A30D\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:oracle:database:19c:*:*:*:enterprise:*:*:*\",\"matchCriteriaId\":\"C1E05472-8F3A-4E46-90E5-50EA6D555FDC\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:oracle:http_server:11.1.1.9.0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"EBD2676F-EE9D-4462-ABA5-C11CE726849C\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:oracle:http_server:12.1.3.0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"DD4552F9-F5B9-4A52-BA5C-D32D49FABD28\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:oracle:http_server:12.2.1.4.0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"AD04BEE5-E9A8-4584-A68C-0195CE9C402C\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:oracle:security_service:11.1.1.9.0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"008518E5-4814-46AA-B9E7-A3B2635D6D4B\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:oracle:security_service:12.1.3.0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"D47F41D7-8C75-47F3-8DF3-CC15378FBB71\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:oracle:security_service:12.2.1.4.0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"D345C2D3-6AA5-4573-8397-ED1EB0153DB9\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:oracle:weblogic_server_proxy_plug-in:11.1.1.9.0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"068876EF-0594-4BE6-B9EC-04730837013E\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:oracle:weblogic_server_proxy_plug-in:12.1.3.0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"DF3EA2E7-D903-4AA3-B38C-1EE71DF52276\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:oracle:weblogic_server_proxy_plug-in:12.2.1.4.0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"5E29C004-51D7-4BBE-B28A-EE6B7B10F89F\"}]}]}],\"references\":[{\"url\":\"https://www.dell.com/support/kbdoc/en-us/000181098/dsa-2020-114-dell-bsafe-micro-edition-suite-multiple-security-vulnerabilities\",\"source\":\"security_alert@emc.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://www.oracle.com/security-alerts/cpuApr2021.html\",\"source\":\"security_alert@emc.com\",\"tags\":[\"Patch\",\"Third Party Advisory\"]}]}}"
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading...

Loading...

Loading...

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.