CVE-2020-5801 (GCVE-0-2020-5801)
Vulnerability from cvelistv5 – Published: 2020-12-29 15:15 – Updated: 2024-08-04 08:39
VLAI?
Summary
An attacker can craft and send an OpenNamespace message to port 4241 with valid session-id that triggers an unhandled exception in CFTLDManager::HandleRequest function in RnaDaSvr.dll, resulting in process termination. Observed in FactoryTalk Linx 6.11. All versions of FactoryTalk Linx are affected.
Severity ?
No CVSS data available.
CWE
- Unauthenticated Remote DoS
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| n/a | Rockwell FactoryTalk Linx |
Affected:
All versions of FactoryTalk Linx
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T08:39:26.067Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://www.tenable.com/security/research/tra-2020-71"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Rockwell FactoryTalk Linx",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "All versions of FactoryTalk Linx"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An attacker can craft and send an OpenNamespace message to port 4241 with valid session-id that triggers an unhandled exception in CFTLDManager::HandleRequest function in RnaDaSvr.dll, resulting in process termination. Observed in FactoryTalk Linx 6.11. All versions of FactoryTalk Linx are affected."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "Unauthenticated Remote DoS",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-12-29T15:15:32",
"orgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
"shortName": "tenable"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://www.tenable.com/security/research/tra-2020-71"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "vulnreport@tenable.com",
"ID": "CVE-2020-5801",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Rockwell FactoryTalk Linx",
"version": {
"version_data": [
{
"version_value": "All versions of FactoryTalk Linx"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "An attacker can craft and send an OpenNamespace message to port 4241 with valid session-id that triggers an unhandled exception in CFTLDManager::HandleRequest function in RnaDaSvr.dll, resulting in process termination. Observed in FactoryTalk Linx 6.11. All versions of FactoryTalk Linx are affected."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Unauthenticated Remote DoS"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.tenable.com/security/research/tra-2020-71",
"refsource": "CONFIRM",
"url": "https://www.tenable.com/security/research/tra-2020-71"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
"assignerShortName": "tenable",
"cveId": "CVE-2020-5801",
"datePublished": "2020-12-29T15:15:32",
"dateReserved": "2020-01-06T00:00:00",
"dateUpdated": "2024-08-04T08:39:26.067Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"fkie_nvd": {
"configurations": "[{\"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:rockwellautomation:factorytalk_linx:*:*:*:*:*:*:*:*\", \"versionEndIncluding\": \"6.11\", \"matchCriteriaId\": \"89622117-4485-4204-A5DA-B72F7F13D353\"}]}]}]",
"descriptions": "[{\"lang\": \"en\", \"value\": \"An attacker can craft and send an OpenNamespace message to port 4241 with valid session-id that triggers an unhandled exception in CFTLDManager::HandleRequest function in RnaDaSvr.dll, resulting in process termination. Observed in FactoryTalk Linx 6.11. All versions of FactoryTalk Linx are affected.\"}, {\"lang\": \"es\", \"value\": \"Un atacante puede crear y enviar un mensaje OpenNamespace al puerto 4241 con un ID de sesi\\u00f3n v\\u00e1lido que desencadena una excepci\\u00f3n no controlada en la funci\\u00f3n CFTLDManager::HandleRequest en la biblioteca RnaDaSvr.dll, resultando en una terminaci\\u00f3n del proceso.\u0026#xa0;Observado en FactoryTalk Linx versi\\u00f3n 6.11.\u0026#xa0;Todas las versiones de FactoryTalk Linx est\\u00e1n afectadas\"}]",
"id": "CVE-2020-5801",
"lastModified": "2024-11-21T05:34:37.333",
"metrics": "{\"cvssMetricV31\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\", \"baseScore\": 7.5, \"baseSeverity\": \"HIGH\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"NONE\", \"integrityImpact\": \"NONE\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 3.9, \"impactScore\": 3.6}], \"cvssMetricV2\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"2.0\", \"vectorString\": \"AV:N/AC:L/Au:N/C:N/I:N/A:P\", \"baseScore\": 5.0, \"accessVector\": \"NETWORK\", \"accessComplexity\": \"LOW\", \"authentication\": \"NONE\", \"confidentialityImpact\": \"NONE\", \"integrityImpact\": \"NONE\", \"availabilityImpact\": \"PARTIAL\"}, \"baseSeverity\": \"MEDIUM\", \"exploitabilityScore\": 10.0, \"impactScore\": 2.9, \"acInsufInfo\": false, \"obtainAllPrivilege\": false, \"obtainUserPrivilege\": false, \"obtainOtherPrivilege\": false, \"userInteractionRequired\": false}]}",
"published": "2020-12-29T16:15:14.730",
"references": "[{\"url\": \"https://www.tenable.com/security/research/tra-2020-71\", \"source\": \"vulnreport@tenable.com\", \"tags\": [\"Third Party Advisory\"]}, {\"url\": \"https://www.tenable.com/security/research/tra-2020-71\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Third Party Advisory\"]}]",
"sourceIdentifier": "vulnreport@tenable.com",
"vulnStatus": "Modified",
"weaknesses": "[{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-755\"}]}]"
},
"nvd": "{\"cve\":{\"id\":\"CVE-2020-5801\",\"sourceIdentifier\":\"vulnreport@tenable.com\",\"published\":\"2020-12-29T16:15:14.730\",\"lastModified\":\"2024-11-21T05:34:37.333\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"An attacker can craft and send an OpenNamespace message to port 4241 with valid session-id that triggers an unhandled exception in CFTLDManager::HandleRequest function in RnaDaSvr.dll, resulting in process termination. Observed in FactoryTalk Linx 6.11. All versions of FactoryTalk Linx are affected.\"},{\"lang\":\"es\",\"value\":\"Un atacante puede crear y enviar un mensaje OpenNamespace al puerto 4241 con un ID de sesi\u00f3n v\u00e1lido que desencadena una excepci\u00f3n no controlada en la funci\u00f3n CFTLDManager::HandleRequest en la biblioteca RnaDaSvr.dll, resultando en una terminaci\u00f3n del proceso.\u0026#xa0;Observado en FactoryTalk Linx versi\u00f3n 6.11.\u0026#xa0;Todas las versiones de FactoryTalk Linx est\u00e1n afectadas\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\",\"baseScore\":7.5,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":3.6}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:N/C:N/I:N/A:P\",\"baseScore\":5.0,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"PARTIAL\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":10.0,\"impactScore\":2.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-755\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:rockwellautomation:factorytalk_linx:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"6.11\",\"matchCriteriaId\":\"89622117-4485-4204-A5DA-B72F7F13D353\"}]}]}],\"references\":[{\"url\":\"https://www.tenable.com/security/research/tra-2020-71\",\"source\":\"vulnreport@tenable.com\",\"tags\":[\"Third Party Advisory\"]},{\"url\":\"https://www.tenable.com/security/research/tra-2020-71\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\"]}]}}"
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…