CVE-2021-22779 (GCVE-0-2021-22779)

Vulnerability from cvelistv5 – Published: 2021-07-14 14:26 – Updated: 2024-08-03 18:51
VLAI?
Summary
Authentication Bypass by Spoofing vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Control Expert V15.0 SP1, EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), SCADAPack RemoteConnect for x70 (all versions), Modicon M580 CPU (all versions - part numbers BMEP* and BMEH*), Modicon M340 CPU (all versions - part numbers BMXP34*), that could cause unauthorized access in read and write mode to the controller by spoofing the Modbus communication between the engineering software and the controller.
Severity ?
No CVSS data available.
CWE
  • CWE-290 - Authentication Bypass by Spoofing
Assigner
References
Impacted products
Vendor Product Version
n/a EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Control Expert V15.0 SP1, EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), SCADAPack RemoteConnect for x70 (all versions), Modicon M580 CPU (all versions - part numbers BMEP* and BMEH*), Modicon M340 CPU (all versions - part numbers BMXP34*) Affected: EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Control Expert V15.0 SP1, EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), SCADAPack RemoteConnect for x70 (all versions), Modicon M580 CPU (all versions - part numbers BMEP* and BMEH*), Modicon M340 CPU (all versions - part numbers BMXP34*)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T18:51:07.432Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-194-01"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Control Expert V15.0 SP1, EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), SCADAPack RemoteConnect for x70 (all versions), Modicon M580 CPU (all versions - part numbers BMEP* and BMEH*), Modicon M340 CPU (all versions - part numbers BMXP34*)",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Control Expert V15.0 SP1, EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), SCADAPack RemoteConnect for x70 (all versions), Modicon M580 CPU (all versions - part numbers BMEP* and BMEH*), Modicon M340 CPU (all versions - part numbers BMXP34*)"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Authentication Bypass by Spoofing vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Control Expert V15.0 SP1, EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), SCADAPack RemoteConnect for x70 (all versions), Modicon M580 CPU (all versions - part numbers BMEP* and BMEH*), Modicon M340 CPU (all versions - part numbers BMXP34*), that could cause unauthorized access in read and write mode to the controller by spoofing the Modbus communication between the engineering software and the controller."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-290",
              "description": "CWE-290: Authentication Bypass by Spoofing",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-07-14T14:26:41",
        "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "shortName": "schneider"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-194-01"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cybersecurity@schneider-electric.com",
          "ID": "CVE-2021-22779",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Control Expert V15.0 SP1, EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), SCADAPack RemoteConnect for x70 (all versions), Modicon M580 CPU (all versions - part numbers BMEP* and BMEH*), Modicon M340 CPU (all versions - part numbers BMXP34*)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Control Expert V15.0 SP1, EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), SCADAPack RemoteConnect for x70 (all versions), Modicon M580 CPU (all versions - part numbers BMEP* and BMEH*), Modicon M340 CPU (all versions - part numbers BMXP34*)"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Authentication Bypass by Spoofing vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Control Expert V15.0 SP1, EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), SCADAPack RemoteConnect for x70 (all versions), Modicon M580 CPU (all versions - part numbers BMEP* and BMEH*), Modicon M340 CPU (all versions - part numbers BMXP34*), that could cause unauthorized access in read and write mode to the controller by spoofing the Modbus communication between the engineering software and the controller."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-290: Authentication Bypass by Spoofing"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-194-01",
              "refsource": "MISC",
              "url": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-194-01"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
    "assignerShortName": "schneider",
    "cveId": "CVE-2021-22779",
    "datePublished": "2021-07-14T14:26:41",
    "dateReserved": "2021-01-06T00:00:00",
    "dateUpdated": "2024-08-03T18:51:07.432Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "fkie_nvd": {
      "configurations": "[{\"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:schneider-electric:ecostruxure_control_expert:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"15.0\", \"matchCriteriaId\": \"43140BF9-455B-4E3C-BF5E-BB9BBF9802D2\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:schneider-electric:ecostruxure_control_expert:15.0:-:*:*:*:*:*:*\", \"matchCriteriaId\": \"A9BF2D84-901E-4D34-941F-FFAB85B0E9D3\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:schneider-electric:ecostruxure_control_expert:15.0:sp1:*:*:*:*:*:*\", \"matchCriteriaId\": \"939C02B6-B5C5-4F87-8179-4AFFE13FCFD2\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:schneider-electric:ecostruxure_process_expert:*:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"FD97669F-93D5-42C4-BFC4-1993867F5911\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:schneider-electric:remoteconnect:*:*:*:*:*:*:scadapack_x70:*\", \"matchCriteriaId\": \"2D7E0B75-171E-4A73-B722-13473CE1B9D7\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:schneider-electric:modicon_m580_bmep581020_firmware:*:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"49646E6C-381F-495B-A5E8-8F522571D4AD\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:schneider-electric:modicon_m580_bmep581020:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"2317F260-7AA2-4178-B468-03DF36223E26\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:schneider-electric:modicon_m580_bmep581020h_firmware:*:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"2F472ED1-8FE6-43BC-A4FF-E956D17ED427\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:schneider-electric:modicon_m580_bmep581020h:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"3D7DDC42-37A1-43B0-AD46-2E0D098564BA\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:schneider-electric:modicon_m580_bmep582020_firmware:*:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"3F1315A8-FDEE-487F-BA66-A99745783911\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:schneider-electric:modicon_m580_bmep582020:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"765E4FEE-255E-4C47-824A-5661B84B490B\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:schneider-electric:modicon_m580_bmep582020h_firmware:*:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"F543A095-B798-4C5B-A2B6-DF893191EAC3\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:schneider-electric:modicon_m580_bmep582020h:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"B1FEA377-3C45-4F88-B233-088A24BD0771\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:schneider-electric:modicon_m580_bmep582040_firmware:*:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"71823B23-C4E6-40EC-AC9C-2EABFDAFE498\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:schneider-electric:modicon_m580_bmep582040:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"EBCCDD6D-35CE-4680-8B0C-86584B1D8958\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:schneider-electric:modicon_m580_bmep582040h_firmware:*:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"3BDD13AD-681C-4C7D-82D5-3017FB3BE852\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:schneider-electric:modicon_m580_bmep582040h:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"68FD5968-C522-4231-A98C-93D3101B6148\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:schneider-electric:modicon_m580_bmep582040s_firmware:*:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"B782A209-0612-4CA1-8438-6653D75F452C\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:schneider-electric:modicon_m580_bmep582040s:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"C02B27F6-B8CF-4D3B-9DA6-054F540EA6B6\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:schneider-electric:modicon_m580_bmep583020_firmware:*:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"43B3DF32-480E-4CE1-9396-B33CD5F63A22\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:schneider-electric:modicon_m580_bmep583020:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"BBC38FF1-693E-4899-883C-1B7B80A52F2C\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:schneider-electric:modicon_m580_bmep583040_firmware:*:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"EA09FB51-0FDC-4457-8ED6-A963CAB97DF4\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:schneider-electric:modicon_m580_bmep583040:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"002E7F33-6729-4C35-9DDA-7D8383BD5668\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:schneider-electric:modicon_m580_bmep584020_firmware:*:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"A9C82569-7D6C-4FD9-B5BB-2E9576FDFB0E\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:schneider-electric:modicon_m580_bmep584020:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"47DFEBAC-2F1D-4870-8425-2199BF80B425\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:schneider-electric:modicon_m580_bmep584040_firmware:*:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"1DC98F7D-BDCC-4CF1-BA80-55EA68C5DDB5\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:schneider-electric:modicon_m580_bmep584040:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"FC4A1DF2-FF4C-4DBE-BF74-6A4A09E3DECE\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:schneider-electric:modicon_m580_bmep584040s_firmware:*:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"CB7741EA-7955-4FC6-BE64-23EFBB0E3DC6\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:schneider-electric:modicon_m580_bmep584040s:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"6222C1F8-BE52-4666-B7F5-2E8BBC214F70\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:schneider-electric:modicon_m580_bmep585040_firmware:*:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"252FA576-D00F-4BF2-871D-291D209B443C\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:schneider-electric:modicon_m580_bmep585040:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"5376D9F4-8AFB-4909-A11B-33C54C4220DB\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:schneider-electric:modicon_m580_bmep585040c_firmware:*:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"2786E51E-B042-4DEF-98CE-C46F381D468C\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:schneider-electric:modicon_m580_bmep585040c:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"CADB178B-FEFD-48A9-B155-0E8F6D490229\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:schneider-electric:modicon_m580_bmep586040_firmware:*:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"0D9E6C74-FAEE-49D3-807B-7F8416C12725\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:schneider-electric:modicon_m580_bmep586040:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"6B3C1879-269B-47EB-891B-EF2E90C911D7\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:schneider-electric:modicon_m580_bmep586040c_firmware:*:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"B182E938-6B50-4F3A-BAF6-AD2637E31E43\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:schneider-electric:modicon_m580_bmep586040c:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"5771A1A5-3DAF-4869-A24F-F9B0A38B5DA5\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:schneider-electric:modicon_m580_bmeh582040_firmware:*:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"8C610F17-FD8F-425E-A169-47EA7E6E8A0A\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:schneider-electric:modicon_m580_bmeh582040:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"F484F8BB-60B5-4045-92C3-0C2A0CD4107E\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:schneider-electric:modicon_m580_bmeh582040c_firmware:*:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"355FFF2A-2B69-4340-AC49-257C0DC63B70\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:schneider-electric:modicon_m580_bmeh582040c:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"F4F0F823-89EA-451D-81DC-07AACA039371\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:schneider-electric:modicon_m580_bmeh582040s_firmware:*:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"777E63F4-CC75-4D68-98CC-896C58EBDD5A\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:schneider-electric:modicon_m580_bmeh582040s:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"610AE743-9FD1-4149-AD45-3B1DAE268BF9\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:schneider-electric:modicon_m580_bmeh584040_firmware:*:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"BF0ACFD6-D1EE-4C25-A307-2E3FB67F4A20\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:schneider-electric:modicon_m580_bmeh584040:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"77116949-1141-432D-964B-29A759939E8F\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:schneider-electric:modicon_m580_bmeh584040c_firmware:*:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"AB46DD56-7A06-428C-97CB-E01C22BC8214\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:schneider-electric:modicon_m580_bmeh584040c:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"B6CE23A2-09CC-4417-A45F-63BCA66C4DD8\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:schneider-electric:modicon_m580_bmeh584040s_firmware:*:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"29482B31-563A-4931-B11E-FDE86F87F25E\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:schneider-electric:modicon_m580_bmeh584040s:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"97AAD857-95C0-4AE3-8510-CB306E8293F4\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:schneider-electric:modicon_m580_bmeh586040_firmware:*:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"1D261663-D224-4C92-A3F4-3509CAA78A36\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:schneider-electric:modicon_m580_bmeh586040:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"07E2FB94-F402-4CF0-BE35-574C1C6528BA\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:schneider-electric:modicon_m580_bmeh586040c_firmware:*:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"6C6737F3-F881-4BDC-A4F4-F6F08B88EC1E\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:schneider-electric:modicon_m580_bmeh586040c:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"2E776EE9-A662-4068-A61A-62CAE23C87F7\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:schneider-electric:modicon_m580_bmeh586040s_firmware:*:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"CEBCF494-DC4C-4567-A5C8-2C8D93BAF289\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:schneider-electric:modicon_m580_bmeh586040s:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"D53BD038-D594-41FF-B3EF-3365C5432AD0\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:schneider-electric:modicon_m340_bmxp341000_firmware:*:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"8152BD1B-DB69-4BD0-9DD3-79FC059319B1\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:schneider-electric:modicon_m340_bmxp341000:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"178D2338-E48E-493C-992F-337AACE794DE\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:schneider-electric:modicon_m340_bmxp342010_firmware:*:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"4A4A2D03-6D4E-4ED9-A0CE-3DD681CB6E9F\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:schneider-electric:modicon_m340_bmxp342010:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"833B2455-5D39-4457-9D6F-0CD738A2EB02\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:schneider-electric:modicon_m340_bmxp342020_firmware:*:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"C747D719-51A2-44F5-B940-89D84437DA95\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:schneider-electric:modicon_m340_bmxp342020:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"99F2F851-C18F-4CB8-B47C-516F2AC7955D\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:schneider-electric:modicon_m340_bmxp342030_firmware:*:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"34CC8BAD-3D4F-4DAD-B8CE-09D0BF4A5E11\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:schneider-electric:modicon_m340_bmxp342030:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"E472ABB0-5556-4B96-9CEF-2180E24FA7FD\"}]}]}]",
      "descriptions": "[{\"lang\": \"en\", \"value\": \"Authentication Bypass by Spoofing vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Control Expert V15.0 SP1, EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), SCADAPack RemoteConnect for x70 (all versions), Modicon M580 CPU (all versions - part numbers BMEP* and BMEH*), Modicon M340 CPU (all versions - part numbers BMXP34*), that could cause unauthorized access in read and write mode to the controller by spoofing the Modbus communication between the engineering software and the controller.\"}, {\"lang\": \"es\", \"value\": \"Se presenta una vulnerabilidad de Omisi\\u00f3n de Autenticaci\\u00f3n por Spoofing en EcoStruxure Control Expert (todas las versiones anteriores a V15.0 SP1, incluyendo todas las versiones de Unity Pro), EcoStruxure Control Expert versi\\u00f3n V15.0 SP1, EcoStruxure Process Expert (todas las versiones, incluyendo todas las versiones de EcoStruxure Hybrid DCS), SCADAPack RemoteConnect for x70 (todas las versiones), Modicon M580 CPU (todas las versiones - n\\u00fameros de parte BMEP* y BMEH*), Modicon M340 CPU (todas las versiones - n\\u00fameros de parte BMXP34*), que podr\\u00eda causar un acceso no autorizado en modo de lectura y escritura al controlador mediante el spoofing de la comunicaci\\u00f3n Modbus entre el software de ingenier\\u00eda y el controlador\"}]",
      "id": "CVE-2021-22779",
      "lastModified": "2024-11-21T05:50:38.990",
      "metrics": "{\"cvssMetricV31\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N\", \"baseScore\": 9.1, \"baseSeverity\": \"CRITICAL\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"NONE\"}, \"exploitabilityScore\": 3.9, \"impactScore\": 5.2}], \"cvssMetricV2\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"2.0\", \"vectorString\": \"AV:N/AC:L/Au:N/C:P/I:P/A:N\", \"baseScore\": 6.4, \"accessVector\": \"NETWORK\", \"accessComplexity\": \"LOW\", \"authentication\": \"NONE\", \"confidentialityImpact\": \"PARTIAL\", \"integrityImpact\": \"PARTIAL\", \"availabilityImpact\": \"NONE\"}, \"baseSeverity\": \"MEDIUM\", \"exploitabilityScore\": 10.0, \"impactScore\": 4.9, \"acInsufInfo\": false, \"obtainAllPrivilege\": false, \"obtainUserPrivilege\": false, \"obtainOtherPrivilege\": false, \"userInteractionRequired\": false}]}",
      "published": "2021-07-14T15:15:08.240",
      "references": "[{\"url\": \"http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-194-01\", \"source\": \"cybersecurity@se.com\", \"tags\": [\"Vendor Advisory\"]}, {\"url\": \"http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-194-01\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Vendor Advisory\"]}]",
      "sourceIdentifier": "cybersecurity@se.com",
      "vulnStatus": "Modified",
      "weaknesses": "[{\"source\": \"cybersecurity@se.com\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-290\"}]}]"
    },
    "nvd": "{\"cve\":{\"id\":\"CVE-2021-22779\",\"sourceIdentifier\":\"cybersecurity@se.com\",\"published\":\"2021-07-14T15:15:08.240\",\"lastModified\":\"2024-11-21T05:50:38.990\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Authentication Bypass by Spoofing vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Control Expert V15.0 SP1, EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), SCADAPack RemoteConnect for x70 (all versions), Modicon M580 CPU (all versions - part numbers BMEP* and BMEH*), Modicon M340 CPU (all versions - part numbers BMXP34*), that could cause unauthorized access in read and write mode to the controller by spoofing the Modbus communication between the engineering software and the controller.\"},{\"lang\":\"es\",\"value\":\"Se presenta una vulnerabilidad de Omisi\u00f3n de Autenticaci\u00f3n por Spoofing en EcoStruxure Control Expert (todas las versiones anteriores a V15.0 SP1, incluyendo todas las versiones de Unity Pro), EcoStruxure Control Expert versi\u00f3n V15.0 SP1, EcoStruxure Process Expert (todas las versiones, incluyendo todas las versiones de EcoStruxure Hybrid DCS), SCADAPack RemoteConnect for x70 (todas las versiones), Modicon M580 CPU (todas las versiones - n\u00fameros de parte BMEP* y BMEH*), Modicon M340 CPU (todas las versiones - n\u00fameros de parte BMXP34*), que podr\u00eda causar un acceso no autorizado en modo de lectura y escritura al controlador mediante el spoofing de la comunicaci\u00f3n Modbus entre el software de ingenier\u00eda y el controlador\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N\",\"baseScore\":9.1,\"baseSeverity\":\"CRITICAL\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":3.9,\"impactScore\":5.2}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:N/C:P/I:P/A:N\",\"baseScore\":6.4,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"NONE\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":10.0,\"impactScore\":4.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"cybersecurity@se.com\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-290\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:schneider-electric:ecostruxure_control_expert:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"15.0\",\"matchCriteriaId\":\"43140BF9-455B-4E3C-BF5E-BB9BBF9802D2\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:schneider-electric:ecostruxure_control_expert:15.0:-:*:*:*:*:*:*\",\"matchCriteriaId\":\"A9BF2D84-901E-4D34-941F-FFAB85B0E9D3\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:schneider-electric:ecostruxure_control_expert:15.0:sp1:*:*:*:*:*:*\",\"matchCriteriaId\":\"939C02B6-B5C5-4F87-8179-4AFFE13FCFD2\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:schneider-electric:ecostruxure_process_expert:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"FD97669F-93D5-42C4-BFC4-1993867F5911\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:schneider-electric:remoteconnect:*:*:*:*:*:*:scadapack_x70:*\",\"matchCriteriaId\":\"2D7E0B75-171E-4A73-B722-13473CE1B9D7\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:modicon_m580_bmep581020_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"49646E6C-381F-495B-A5E8-8F522571D4AD\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:modicon_m580_bmep581020:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"2317F260-7AA2-4178-B468-03DF36223E26\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:modicon_m580_bmep581020h_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"2F472ED1-8FE6-43BC-A4FF-E956D17ED427\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:modicon_m580_bmep581020h:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"3D7DDC42-37A1-43B0-AD46-2E0D098564BA\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:modicon_m580_bmep582020_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"3F1315A8-FDEE-487F-BA66-A99745783911\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:modicon_m580_bmep582020:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"765E4FEE-255E-4C47-824A-5661B84B490B\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:modicon_m580_bmep582020h_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"F543A095-B798-4C5B-A2B6-DF893191EAC3\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:modicon_m580_bmep582020h:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"B1FEA377-3C45-4F88-B233-088A24BD0771\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:modicon_m580_bmep582040_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"71823B23-C4E6-40EC-AC9C-2EABFDAFE498\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:modicon_m580_bmep582040:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"EBCCDD6D-35CE-4680-8B0C-86584B1D8958\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:modicon_m580_bmep582040h_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"3BDD13AD-681C-4C7D-82D5-3017FB3BE852\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:modicon_m580_bmep582040h:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"68FD5968-C522-4231-A98C-93D3101B6148\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:modicon_m580_bmep582040s_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"B782A209-0612-4CA1-8438-6653D75F452C\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:modicon_m580_bmep582040s:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"C02B27F6-B8CF-4D3B-9DA6-054F540EA6B6\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:modicon_m580_bmep583020_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"43B3DF32-480E-4CE1-9396-B33CD5F63A22\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:modicon_m580_bmep583020:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"BBC38FF1-693E-4899-883C-1B7B80A52F2C\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:modicon_m580_bmep583040_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"EA09FB51-0FDC-4457-8ED6-A963CAB97DF4\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:modicon_m580_bmep583040:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"002E7F33-6729-4C35-9DDA-7D8383BD5668\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:modicon_m580_bmep584020_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"A9C82569-7D6C-4FD9-B5BB-2E9576FDFB0E\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:modicon_m580_bmep584020:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"47DFEBAC-2F1D-4870-8425-2199BF80B425\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:modicon_m580_bmep584040_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"1DC98F7D-BDCC-4CF1-BA80-55EA68C5DDB5\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:modicon_m580_bmep584040:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"FC4A1DF2-FF4C-4DBE-BF74-6A4A09E3DECE\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:modicon_m580_bmep584040s_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"CB7741EA-7955-4FC6-BE64-23EFBB0E3DC6\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:modicon_m580_bmep584040s:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"6222C1F8-BE52-4666-B7F5-2E8BBC214F70\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:modicon_m580_bmep585040_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"252FA576-D00F-4BF2-871D-291D209B443C\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:modicon_m580_bmep585040:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"5376D9F4-8AFB-4909-A11B-33C54C4220DB\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:modicon_m580_bmep585040c_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"2786E51E-B042-4DEF-98CE-C46F381D468C\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:modicon_m580_bmep585040c:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"CADB178B-FEFD-48A9-B155-0E8F6D490229\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:modicon_m580_bmep586040_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"0D9E6C74-FAEE-49D3-807B-7F8416C12725\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:modicon_m580_bmep586040:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"6B3C1879-269B-47EB-891B-EF2E90C911D7\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:modicon_m580_bmep586040c_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"B182E938-6B50-4F3A-BAF6-AD2637E31E43\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:modicon_m580_bmep586040c:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"5771A1A5-3DAF-4869-A24F-F9B0A38B5DA5\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:modicon_m580_bmeh582040_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"8C610F17-FD8F-425E-A169-47EA7E6E8A0A\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:modicon_m580_bmeh582040:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"F484F8BB-60B5-4045-92C3-0C2A0CD4107E\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:modicon_m580_bmeh582040c_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"355FFF2A-2B69-4340-AC49-257C0DC63B70\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:modicon_m580_bmeh582040c:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"F4F0F823-89EA-451D-81DC-07AACA039371\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:modicon_m580_bmeh582040s_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"777E63F4-CC75-4D68-98CC-896C58EBDD5A\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:modicon_m580_bmeh582040s:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"610AE743-9FD1-4149-AD45-3B1DAE268BF9\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:modicon_m580_bmeh584040_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"BF0ACFD6-D1EE-4C25-A307-2E3FB67F4A20\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:modicon_m580_bmeh584040:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"77116949-1141-432D-964B-29A759939E8F\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:modicon_m580_bmeh584040c_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"AB46DD56-7A06-428C-97CB-E01C22BC8214\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:modicon_m580_bmeh584040c:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"B6CE23A2-09CC-4417-A45F-63BCA66C4DD8\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:modicon_m580_bmeh584040s_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"29482B31-563A-4931-B11E-FDE86F87F25E\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:modicon_m580_bmeh584040s:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"97AAD857-95C0-4AE3-8510-CB306E8293F4\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:modicon_m580_bmeh586040_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"1D261663-D224-4C92-A3F4-3509CAA78A36\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:modicon_m580_bmeh586040:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"07E2FB94-F402-4CF0-BE35-574C1C6528BA\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:modicon_m580_bmeh586040c_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"6C6737F3-F881-4BDC-A4F4-F6F08B88EC1E\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:modicon_m580_bmeh586040c:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"2E776EE9-A662-4068-A61A-62CAE23C87F7\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:modicon_m580_bmeh586040s_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"CEBCF494-DC4C-4567-A5C8-2C8D93BAF289\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:modicon_m580_bmeh586040s:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"D53BD038-D594-41FF-B3EF-3365C5432AD0\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:modicon_m340_bmxp341000_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"8152BD1B-DB69-4BD0-9DD3-79FC059319B1\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:modicon_m340_bmxp341000:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"178D2338-E48E-493C-992F-337AACE794DE\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:modicon_m340_bmxp342010_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"4A4A2D03-6D4E-4ED9-A0CE-3DD681CB6E9F\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:modicon_m340_bmxp342010:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"833B2455-5D39-4457-9D6F-0CD738A2EB02\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:modicon_m340_bmxp342020_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"C747D719-51A2-44F5-B940-89D84437DA95\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:modicon_m340_bmxp342020:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"99F2F851-C18F-4CB8-B47C-516F2AC7955D\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:modicon_m340_bmxp342030_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"34CC8BAD-3D4F-4DAD-B8CE-09D0BF4A5E11\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:modicon_m340_bmxp342030:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"E472ABB0-5556-4B96-9CEF-2180E24FA7FD\"}]}]}],\"references\":[{\"url\":\"http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-194-01\",\"source\":\"cybersecurity@se.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-194-01\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]}]}}"
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.


Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…