CVE-2022-38380
Vulnerability from cvelistv5
Published
2022-11-02 00:00
Modified
2024-10-22 20:52
Summary
An improper access control [CWE-284] vulnerability in FortiOS version 7.2.0 and versions 7.0.0 through 7.0.7 may allow a remote authenticated read-only user to modify the interface settings via the API.
Impacted products
FortinetFortinet FortiOS
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T10:54:03.669Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://fortiguard.com/psirt/FG-IR-22-174"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-38380",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-10-22T20:19:00.406483Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-10-22T20:52:46.827Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Fortinet FortiOS",
          "vendor": "Fortinet",
          "versions": [
            {
              "status": "affected",
              "version": "FortiOS 7.2.0, 7.0.7, 7.0.6, 7.0.5, 7.0.4, 7.0.3, 7.0.2, 7.0.1, 7.0.0"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "An improper access control [CWE-284] vulnerability in FortiOS version 7.2.0 and versions 7.0.0 through 7.0.7 may allow a remote authenticated read-only user to modify the interface settings via the API."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 4.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "exploitCodeMaturity": "FUNCTIONAL",
            "integrityImpact": "LOW",
            "privilegesRequired": "LOW",
            "remediationLevel": "NOT_DEFINED",
            "reportConfidence": "NOT_DEFINED",
            "scope": "UNCHANGED",
            "temporalScore": 4.2,
            "temporalSeverity": "MEDIUM",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:N/E:F/RL:X/RC:X",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "Improper access control",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-11-02T00:00:00",
        "orgId": "6abe59d8-c742-4dff-8ce8-9b0ca1073da8",
        "shortName": "fortinet"
      },
      "references": [
        {
          "url": "https://fortiguard.com/psirt/FG-IR-22-174"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "6abe59d8-c742-4dff-8ce8-9b0ca1073da8",
    "assignerShortName": "fortinet",
    "cveId": "CVE-2022-38380",
    "datePublished": "2022-11-02T00:00:00",
    "dateReserved": "2022-08-16T00:00:00",
    "dateUpdated": "2024-10-22T20:52:46.827Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2022-38380\",\"sourceIdentifier\":\"psirt@fortinet.com\",\"published\":\"2022-11-02T12:15:54.547\",\"lastModified\":\"2022-11-04T14:56:46.817\",\"vulnStatus\":\"Analyzed\",\"descriptions\":[{\"lang\":\"en\",\"value\":\"An improper access control [CWE-284] vulnerability in FortiOS version 7.2.0 and versions 7.0.0 through 7.0.7 may allow a remote authenticated read-only user to modify the interface settings via the API.\"},{\"lang\":\"es\",\"value\":\"Una vulnerabilidad de control de acceso inadecuado [CWE-284] en FortiOS versi\u00f3n 7.2.0 y versiones 7.0.0 a 7.0.7 puede permitir que un usuario remoto de solo lectura autenticado modifique la configuraci\u00f3n de la interfaz a trav\u00e9s de la API.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:N\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"LOW\",\"availabilityImpact\":\"NONE\",\"baseScore\":4.3,\"baseSeverity\":\"MEDIUM\"},\"exploitabilityScore\":2.8,\"impactScore\":1.4},{\"source\":\"psirt@fortinet.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:N\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"LOW\",\"availabilityImpact\":\"NONE\",\"baseScore\":4.3,\"baseSeverity\":\"MEDIUM\"},\"exploitabilityScore\":2.8,\"impactScore\":1.4}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"NVD-CWE-Other\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:fortinet:fortios:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"7.0.0\",\"versionEndIncluding\":\"7.0.7\",\"matchCriteriaId\":\"DEC5CAD3-53CB-45C3-B4EA-10AEFE6C0016\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:fortinet:fortios:7.2.0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"B9B87A2A-4C83-448B-8009-AD20214D58CB\"}]}]}],\"references\":[{\"url\":\"https://fortiguard.com/psirt/FG-IR-22-174\",\"source\":\"psirt@fortinet.com\",\"tags\":[\"Vendor Advisory\"]}]}}"
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading...

Loading...

Loading...

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.